Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
BMC Musculoskelet Disord ; 25(1): 159, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38378510

RESUMEN

BACKGROUND: Low bone mineral density affects 53% of women over age 65 in the US, yet many are unaware and remain untreated. Underdiagnosis of forearm osteoporosis and related fragility fractures represent missed warning signs of more deadly, future fractures. This study aimed to determine if hand radiographs could serve as early, simple screening tools for predicting low forearm bone mineral density (BMD). METHODS: We evaluated posterior-anterior (PA) hand radiographs (x-rays) and Dual-energy X-ray absorptiometry (DXA) scans of 43 participants. The ratio of the intramedullary cavity to total cortical diameter of the second metacarpal (second metacarpal cortical percentage (2MCP)) was used as a potential diagnostic marker. Mixed-effects linear regression was performed to determine correlation of 2MCP with BMD from various anatomic regions. Repeated measures ANOVAs were used to compare BMD across sites. An optimal 2MCP cutoff for predicting forearm osteopenia and osteoporosis was found using Receiver Operating Curves. RESULTS: 2MCP is directly correlated with BMD in the forearm. The optimal 2MCP of 48.3% had 80% sensitivity for detecting osteoporosis of the 1/3 distal forearm. An 2MCP cutoff of 50.8% had 84% sensitivity to detect osteoporosis of the most distal forearm. Both 2MCP cutoffs were more sensitive at predicting forearm osteoporosis than femoral neck T-scores. CONCLUSIONS: These findings support the expansion of osteoporosis screening to include low-cost hand x-rays, aiming to increase diagnosis and treatment of low forearm BMD and fractures. Proposed next steps include confirming the optimal 2MCP cutoff at scale and integrating automatic 2MCP measurements into PAC systems.


Asunto(s)
Enfermedades Óseas Metabólicas , Fracturas Óseas , Osteoporosis , Humanos , Femenino , Anciano , Densidad Ósea , Antebrazo/diagnóstico por imagen , Estudios Retrospectivos , Estudios Prospectivos , Osteoporosis/diagnóstico por imagen , Absorciometría de Fotón , Fracturas Óseas/diagnóstico
2.
Eur J Orthop Surg Traumatol ; 34(1): 251-269, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37439887

RESUMEN

AIM: Polymers and metals, such as polyethylene (PE) and cobalt chrome (CoCr), are common materials used in thumb-based joint implants, also known as CMC (Carpometacarpal) arthroplasty. The purpose of this review was to investigate the reported failure modes related to wear debris from these type of materials in CMC implants. The impact of wear debris on clinical outcomes of CMC implants was also examined. Potential adverse wear conditions and inflammatory particle characteristics were also considered. METHOD: A literature search was performed using PRISMA guidelines and 55 studies were reviewed including 49 cohort studies and 6 case studies. Of the 55 studies, 38/55 (69%) focused on metal-on-polyethylene devices, followed by metal-on-metal (35%), and metal-on-bone (4%). RESULTS: The summarized data was used to determine the frequency of failure modes potentially related to wear debris from metals and/or polymers. The most commonly reported incidents potentially relating to debris were implant loosening (7.1%), osteolysis (1.2%) and metallosis (0.6%). Interestingly the reported mechanisms behind osteolysis and loosening greatly varied. Inflammatory reactions, while rare, were generally attributed to metallic debris from metal-on-metal devices. Mechanisms of adverse wear conditions included implant malpositioning, over-tensioning, high loading for active patients, third-body debris, and polyethylene wear-through. No specific examination of debris particle characterization was found, pointing to a gap in the literature. CONCLUSION: This review underscores the types of failure modes associated with wear debris in CMC implants. It was found that failure rates and adverse wear conditions of CMC implants of any design are low and the exact relationship between wear debris and implant incidences, such as osteolysis and loosening remains uncertain. The authors note that further research and specific characterization is required to understand the relationship between debris and implant failure.


Asunto(s)
Osteólisis , Humanos , Osteólisis/etiología , Pulgar/cirugía , Prótesis e Implantes/efectos adversos , Polietileno , Artroplastia/efectos adversos , Metales , Falla de Prótesis
3.
Clin Orthop Relat Res ; 481(6): 1224-1237, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-36877171

RESUMEN

BACKGROUND: Measurable changes in patients with progression of thumb carpometacarpal (CMC) osteoarthritis (OA) include joint space narrowing, osteophyte formation, subluxation, and adjacent-tissue changes. Subluxation, an indication of mechanical instability, is postulated as an early biomechanical indicator of progressing CMC OA. Various radiographic views and hand postures have been proposed to best assess CMC subluxation, but 3D measurements derived from CT images serve as the optimal metric. However, we do not know which thumb pose yields subluxation that most indicates OA progression. QUESTIONS/PURPOSES: Using osteophyte volume as a quantitative measure of OA progression, we asked: (1) Does dorsal subluxation vary by thumb pose, time, and disease severity in patients with thumb CMC OA? (2) In which thumb pose(s) does dorsal subluxation most differentiate patients with stable CMC OA from those with progressing CMC OA? (3) In those poses, what values of dorsal subluxation indicate a high likelihood of CMC OA progression? METHODS: Between 2011 and 2014, 743 patients were seen at our institutions for trapeziometacarpal pain. We considered individuals who were between the ages of 45 and 75 years, had tenderness to palpation or a positive grind test result, and had modified Eaton Stage 0 or 1 radiographic thumb CMC OA as potentially eligible for enrollment. Based on these criteria, 109 patients were eligible. Of the eligible patients, 19 were excluded because of a lack of interest in study participation, and another four were lost before the minimum study follow-up or had incomplete datasets, leaving 86 (43 female patients with a mean age of 53 ± 6 years and 43 male patients with a mean age of 60 ± 7 years) patients for analysis. Twenty-five asymptomatic participants (controls) aged 45 to 75 years were also prospectively recruited to participate in this study. Inclusion criteria for controls included an absence of thumb pain and no evidence of CMC OA during clinical examination. Of the 25 recruited controls, three were lost to follow-up, leaving 22 for analysis (13 female patients with a mean age of 55 ± 7 years and nine male patients with a mean age of 58 ± 9 years). Over the 6-year study period, CT images were acquired of patients and controls in 11 thumb poses: neutral, adduction, abduction, flexion, extension, grasp, jar, pinch, grasp loaded, jar loaded, and pinch loaded. CT images were acquired at enrollment (Year 0) and Years 1.5, 3, 4.5, and 6 for patients and at Years 0 and 6 for controls. From the CT images, bone models of the first metacarpal (MC1) and trapezium were segmented, and coordinate systems were calculated from their CMC articular surfaces. The volar-dorsal location of the MC1 relative to the trapezium was computed and normalized for bone size. Patients were categorized into stable OA and progressing OA subgroups based on trapezial osteophyte volume. MC1 volar-dorsal location was analyzed by thumb pose, time, and disease severity using linear mixed-effects models. Data are reported as the mean and 95% confidence interval. Differences in volar-dorsal location at enrollment and rate of migration during the study were analyzed for each thumb pose by group (control, stable OA, and progressing OA). A receiver operating characteristic curve analysis of MC1 location was used to identify thumb poses that differentiated patients whose OA was stable from those whose OA was progressing. The Youden J statistic was used to determine optimized cutoff values of subluxation from those poses to be tested as indicators of OA progression. Sensitivity, specificity, negative predictive values, and positive predictive values were calculated to assess the performance of pose-specific cutoff values of MC1 locations as indicators of progressing OA. RESULTS: In flexion, the MC1 locations were volar to the joint center in patients with stable OA (mean -6.2% [95% CI -8.8% to -3.6%]) and controls (mean -6.1% [95% CI -8.9% to -3.2%]), while patients with progressing OA exhibited dorsal subluxation (mean 5.0% [95% CI 1.3% to 8.6%]; p < 0.001). The pose associated with the most rapid MC1 dorsal subluxation in the progressing OA group was thumb flexion (mean 3.2% [95% CI 2.5% to 3.9%] increase per year). In contrast, the MC1 migrated dorsally much slower in the stable OA group (p < 0.001), at only a mean of 0.1% (95% CI -0.4% to 0.6%) per year. A cutoff value of 1.5% for the volar MC1 position during flexion at enrollment (C-statistic: 0.70) was a moderate indicator of OA progression, with a high positive predictive value (0.80) but low negative predictive value (0.54). Positive and negative predictive values of subluxation rate in flexion (2.1% per year) were high (0.81 and 0.81, respectively). The metric that most indicated a high likelihood of OA progression (sensitivity 0.96, negative predictive value 0.89) was a dual cutoff that combined the subluxation rate in flexion (2.1% per year) with that of loaded pinch (1.2% per year). CONCLUSION: In the thumb flexion pose, only the progressing OA group exhibited MC1 dorsal subluxation. The MC1 location cutoff value for progression in flexion was 1.5% volar to the trapezium , which suggests that dorsal subluxation of any amount in this pose indicates a high likelihood of thumb CMC OA progression. However, volar MC1 location in flexion alone was not sufficient to rule out progression. The availability of longitudinal data improved our ability to identify patients whose disease will likely remain stable. In patients whose MC1 location during flexion changed < 2.1% per year and whose MC1 location during pinch loading changed < 1.2% per year, the confidence that their disease would remain stable throughout the 6-year study period was very high. These cutoff rates were a lower limit, and any patients whose dorsal subluxation advanced faster than 2% to 1% per year in their respective hand poses, were highly likely to experience progressive disease. CLINICAL RELEVANCE: Our findings suggest that in patients with early signs of CMC OA, nonoperative interventions aimed to reduce further dorsal subluxation or operative treatments that spare the trapezium and limit subluxation may be effective. It remains to be determined whether our subluxation metrics can be rigorously computed from more widely available technologies, such as plain radiography or ultrasound.


Asunto(s)
Articulaciones Carpometacarpianas , Luxaciones Articulares , Osteoartritis , Pulgar , Hueso Trapecio , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Articulaciones Carpometacarpianas/diagnóstico por imagen , Articulaciones Carpometacarpianas/cirugía , Luxaciones Articulares/diagnóstico por imagen , Huesos del Metacarpo , Osteoartritis/diagnóstico por imagen , Osteoartritis/cirugía , Osteofito , Dolor , Pulgar/diagnóstico por imagen , Pulgar/cirugía , Hueso Trapecio/cirugía
4.
J Shoulder Elbow Surg ; 32(1): 174-185, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35987430

RESUMEN

BACKGROUND: The etiology of adhesive capsulitis involves inflammation, thickening, and fibrosis of the shoulder capsule. The underlying genetic factors are poorly understood. The purpose of this study was to identify genetic variants associated with adhesive capsulitis using the UK Biobank (UKB) cohort and compare them with variants associated with Dupuytren disease investigating a common etiology between the 2 fibrotic disorders. METHODS: A genome-wide association study (GWAS) was performed using data from UKB with 10,773 cases of adhesive capsulitis, and a second GWAS was performed with 8891 cases of Dupuytren disease. Next, a comparison of association statistics was performed between adhesive capsulitis and Dupuytren disease using the data from both GWAS. Finally, single-nucleotide polymorphisms (SNPs) previously reported from candidate gene studies for adhesive capsulitis and Dupuytren disease were tested for association with adhesive capsulitis and Dupuytren disease using the summary statistics from their respective GWAS. RESULTS: The UKB GWAS for adhesive capsulitis identified 6 loci that reached genome-wide statistical significance: a cluster of 11 closely linked SNPs on chromosome 1; a single SNP on chromosome 2; a single SNP on chromosome 14; 2 closely linked SNPs on chromosome 21; 33 closely linked SNPs on chromosome 22; and 3 closely linked SNPs on the X chromosome. These SNPs were associated with 8 different genes including TSPAN2/NGF, SATB2, MRPL52/MMP14, ERG, WNT7B, and FGF13. A GWAS for Dupuytren disease was performed and a comparison to the adhesive capsulitis GWAS showed 13 loci significantly associated with both phenotypes. A validation attempt of 6 previously reported SNPs associated with adhesive capsulitis using UKB summary statistics was unable to confirm any of the previously reported SNPs (all P > .19). All 23 previously reported SNPs associated with Dupuytren disease were confirmed using the UKB summary statistics (P < 2.1 × 10-3) CONCLUSION: This GWAS investigating adhesive capsulitis has identified 6 novel loci involving 8 different genes to be associated with adhesive capsulitis. A GWAS investigating Dupuytren disease was performed and compared to the adhesive capsulitis GWAS, and 13 common loci were identified between the 2 disorders with genes involved in pathologic fibrosis. We were unable to validate the SNPs in candidate genes previously reported to be associated with adhesive capsulitis although we were able to confirm all previously reported SNPs associated with Dupuytren disease. The strong genetic overlap between the adhesive capsulitis and Dupuytren disease loci suggests a similar etiology between the 2 diseases.


Asunto(s)
Bursitis , Contractura de Dupuytren , Humanos , Estudio de Asociación del Genoma Completo , Contractura de Dupuytren/genética , Contractura de Dupuytren/patología , Polimorfismo de Nucleótido Simple , Bursitis/genética , Fibrosis
5.
Sensors (Basel) ; 23(20)2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37896527

RESUMEN

Training devices to enhance golf swing technique are increasingly in demand. Golf swing biomechanics are typically assessed in a laboratory setting and not readily accessible. Inertial measurement units (IMUs) offer improved access as they are wearable, cost-effective, and user-friendly. This study investigates the accuracy of IMU-based golf swing kinematics of upper torso and pelvic rotation compared to lab-based 3D motion capture. Thirty-six male and female professional and amateur golfers participated in the study, nine in each sub-group. Golf swing rotational kinematics, including upper torso and pelvic rotation, pelvic rotational velocity, S-factor (shoulder obliquity), O-factor (pelvic obliquity), and X-factor were compared. Strong positive correlations between IMU and 3D motion capture were found for all parameters; Intraclass Correlations ranged from 0.91 (95% confidence interval [CI]: 0.89, 0.93) for O-factor to 1.00 (95% CI: 1.00, 1.00) for upper torso rotation; Pearson coefficients ranged from 0.92 (95% CI: 0.92, 0.93) for O-factor to 1.00 (95% CI: 1.00, 1.00) for upper torso rotation (p < 0.001 for all). Bland-Altman analysis demonstrated good agreement between the two methods; absolute mean differences ranged from 0.61 to 1.67 degrees. Results suggest that IMUs provide a practical and viable alternative for golf swing analysis, offering golfers accessible and wearable biomechanical feedback to enhance performance. Furthermore, integrating IMUs into golf coaching can advance swing analysis and personalized training protocols. In conclusion, IMUs show significant promise as cost-effective and practical devices for golf swing analysis, benefiting golfers across all skill levels and providing benchmarks for training.


Asunto(s)
Golf , Masculino , Humanos , Femenino , Fenómenos Biomecánicos , Torso , Pelvis , Hombro , Movimiento
6.
Instr Course Lect ; 71: 147-162, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35254780

RESUMEN

Thumb carpometacarpal osteoarthritis is commonly encountered and multifactorial in etiology, and its management is based on the radiographic stage and surgeon preference. A variety of management strategies exist including ligament reconstruction, arthroscopic débridement, extension osteotomy, open versus arthroscopic total and partial trapeziectomy with or without interposition and/or suspensionplasty, arthrodesis, and total or hemi implant arthroplasty. A review of the literature shows each of these management strategies to be effective in pain relief, but no one procedure has been shown to be superior despite theoretic benefits to preserving trapezial height. The one common denominator is removal of the arthritic contact between the thumb metacarpal and trapezial surfaces.


Asunto(s)
Articulaciones Carpometacarpianas , Osteoartritis , Hueso Trapecio , Artrodesis , Articulaciones Carpometacarpianas/cirugía , Humanos , Osteoartritis/cirugía , Pulgar/cirugía , Hueso Trapecio/cirugía
7.
J Hand Surg Am ; 47(7): 621-628, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35527094

RESUMEN

PURPOSE: Internal consistency, construct, and criterion validity of the Patient-Reported Outcomes Measurement Information System (PROMIS) upper extremity (UE) v1.2 were evaluated in patients with early-stage carpometacarpal (CMC) osteoarthritis (OA). We hypothesized that in patients with early CMC OA, PROMIS UE scores would: (1) be lower than those in asymptomatic controls; (2) correlate with established patient-reported outcomes; (3) correlate with pinch and grip strengths; and (4) not correlate with radiographic disease progression. METHODS: Patients with early CMC OA (modified Eaton stage 0 or 1) and matched asymptomatic control patients completed the PROMIS UE, Australian and Canadian Osteoarthritis Hand Index, and Patient-Rated Wrist-Hand Evaluation at 2 time points. The PROMIS UE's internal consistency was evaluated by Cronbach's alpha, construct validity by Spearman correlation coefficients among the patient-reported outcome measures, and criterion validity using measures of strength. A floor or ceiling effect was indicated if more than 15% of patients achieved the lowest or highest possible score. RESULTS: The PROMIS UE had high internal consistency. Patients with early CMC OA had a lower score than healthy controls (average, 42 vs 54, respectively). We observed moderate to high correlations between the PROMIS UEv1.2, Australian and Canadian Osteoarthritis Hand Index, and Patient-Rated Wrist-Hand Evaluation and good criterion validity when compared to key pinch and grip strengths. The PROMIS UE did not correlate to radiographic disease severity. CONCLUSIONS: The PROMIS UE had a high correlation with Australian and Canadian Osteoarthritis Hand Index and a moderate correlation with Patient-Rated Wrist-Hand Evaluation. The PROMIS UE had high internal consistency and good criterion validity. CLINICAL RELEVANCE: The PROMIS UE is a valid assessment for disability in patients with early CMC OA and can serve as a clinical adjunct to an outcome assessment.


Asunto(s)
Osteoartritis , Medición de Resultados Informados por el Paciente , Australia , Canadá , Evaluación de la Discapacidad , Humanos , Osteoartritis/diagnóstico por imagen , Extremidad Superior
8.
J Hand Surg Am ; 45(9): 841-849.e1, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32654765

RESUMEN

PURPOSE: Rotational instability of scaphoid fracture nonunions can lead to persistent nonunion. We hypothesized that a hybrid Russe technique would provide improved rotational stability compared with an instrumented corticocancellous wedge graft in a cadaver model of scaphoid nonunion. METHODS: A volar wedge osteotomy was created at the scaphoid waist in 16 scaphoids from matched-pair specimens. A wedge was inset at the osteotomy site or a 4 × 16-mm strut was inserted in the scaphoid and a screw was placed along the central axis (model 1). The construct was cyclically loaded in torsion until failure. The screw was removed and the proximal and distal poles were debrided. A matching wedge and packed cancellous bone graft or an 8 × 20-mm strut was shaped and fit inside the proximal and distal pole (model 2). A screw was placed and testing was repeated. RESULTS: In the first model, there was no significant difference in cycles to failure, target torque, or maximal torque between the strut graft and the wedge graft. Cycles to failure positively correlated with estimated bone density for the wedge graft, but not for the strut graft. In the second model, the strut graft had significantly higher cycles to failure, greater target torque, and higher maximal torque compared with the wedge graft. The number of cycles to failure was not correlated with estimated bone density for the wedge or the strut grafts. CONCLUSIONS: The hybrid Russe technique of inlay corticocancellous strut and screw fixation provides improved rotational stability compared with a wedge graft with screw fixation for a cadaver model of scaphoid waist nonunion with cystic change. CLINICAL RELEVANCE: The hybrid Russe technique may provide better rotational stability for scaphoid waist nonunions when the proximal or distal scaphoid pole is compromised, such as when there is extensive cystic change, when considerable debridement is necessary, or with revision nonunion surgery.


Asunto(s)
Fracturas Óseas , Fracturas no Consolidadas , Hueso Escafoides , Tornillos Óseos , Fijación Interna de Fracturas , Fracturas no Consolidadas/diagnóstico por imagen , Fracturas no Consolidadas/cirugía , Humanos , Hueso Escafoides/diagnóstico por imagen , Hueso Escafoides/cirugía
9.
J Hand Surg Am ; 45(7): 589-596, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32482496

RESUMEN

PURPOSE: Patient-reported outcome measures are increasingly used to measure patient status, impairments, and disability, but often require lengthy surveys and place a considerable burden on patients. We hypothesized that the Single Assessment Numeric Evaluation (SANE), composed of a single question, would be a valid and responsive instrument to provide a global assessment of hand function. METHODS: The SANE, Patient-Reported Outcomes Measurement Information System-Upper Extremity (PROMIS-UE), and Quick-Disabilities of the Arm, Shoulder, and Hand (QuickDASH) data are routinely collected electronically in our hand and upper-extremity center. To identify our cohort, we used Current Procedural Terminology codes to query our electronic medical record research data repository for the 7 most common hand surgery procedures performed over 2 years from December 2016 to 2018. These procedures included carpal tunnel release, trigger finger release, thumb carpometacarpal arthroplasty, wrist arthroscopy, distal radius fracture fixation, first dorsal compartment release, and cubital tunnel release. Patients undergoing a single isolated procedure with questionnaires obtained in the preoperative and/or postoperative period were included in the analysis. Convergent validity, coverage, and responsiveness for each instrument were assessed. RESULTS: We identified 214 patients for inclusion. The SANE score had a moderate to strong correlation with the QuickDASH and PROMIS-UE. Floor and ceiling effects for the SANE were less than 10% at baseline and follow-up. Overall, the QuickDASH was the most responsive, followed by SANE and PROMIS-UE; all 3 instruments exceeded the acceptable thresholds for responsiveness and demonstrated significant changes before to after surgery. Responsiveness of the SANE varied by procedure and was acceptable for carpal tunnel release, carpometacarpal arthroplasty, wrist arthroscopy, and trigger finger release. CONCLUSIONS: The single-item SANE is a reasonable measure of global function in patients undergoing common hand procedures and demonstrates psychometric properties comparable to those of the PROMIS-UE and QuickDASH outcome scores. CLINICAL RELEVANCE: The SANE score is a reasonable outcome measure of global hand function that may have utility in demonstrating response to treatment in a practice setting and may provide a useful adjunct to multiple-item measures in clinical research studies.


Asunto(s)
Síndrome del Túnel Carpiano , Mano , Síndrome del Túnel Carpiano/cirugía , Evaluación de la Discapacidad , Mano/cirugía , Humanos , Medición de Resultados Informados por el Paciente , Encuestas y Cuestionarios , Extremidad Superior
10.
J Hand Surg Am ; 45(11): 1070-1081, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33153531

RESUMEN

This article chronicles some of the major advancements made by the American Society for Surgery of the Hand over the past 25 years since the publication of William Newmeyer III's monograph, American Society for Surgery of the Hand: The First Fifty Years, in 1995. What is intangible and impossible to articulate in this article are the countless stories of relationship building, education, and research advancement that the programming and activities the American Society for Surgery of the Hand has provided.


Asunto(s)
Sociedades Médicas , Humanos , Estados Unidos
11.
J Hand Surg Am ; 44(2): 154.e1-154.e5, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29891266

RESUMEN

PURPOSE: This study examined a palmar beak fracture model to determine which thumb carpometacarpal (CMC) joint ligament is the primary ligament relevant to the pattern of injury. METHODS: Six fresh-frozen cadaveric wrists were used. The radius, ulna, and first metacarpal were secured and tested with a materials testing system, holding the wrist in 20° extension, 20° ulnar deviation, and 30° palmar abduction of the first metacarpal. Testing consisted of preconditioning cycles followed by compressive loading at 100 mm/s. We confirmed fractures with fluoroscopy and dissected the specimens to examine the CMC joint ligaments. The metacarpal was stressed through a range of motion to determine which maneuvers reduced or displaced the fractures. RESULTS: Our model successfully created palmar beak fractures in all cadaveric specimens. All fractures were displaced and intra-articular. The anterior oblique ligament (AOL) was thin and partially attached to the palmar beak fracture fragment. The ulnar collateral ligament was attached in its entirety to the fracture fragment and represented a thicker, more robust ligament compared with the AOL. Radial abduction and pronation of the metacarpal reduced fracture displacement. Extension of the CMC joint or tensioning the AOL did not decrease fracture displacement. CONCLUSIONS: This model successfully created a reproducible and clinically relevant palmar beak fracture in a biomechanical setting. The primary ligament attached to the palmar beak fracture fragment was the ulnar collateral ligament, and not the AOL as previously described. These findings suggest that the AOL may not be a substantial contributor to palmar beak fracture morphology. CLINICAL RELEVANCE: A refined description of the ligamentous anatomy of the palmar break fracture enhances opportunities for improved reduction and treatment of this common hand injury.


Asunto(s)
Fractura-Luxación , Fracturas Intraarticulares , Huesos del Metacarpo/lesiones , Pulgar/lesiones , Cadáver , Fractura-Luxación/diagnóstico por imagen , Fractura-Luxación/patología , Humanos , Fracturas Intraarticulares/diagnóstico por imagen , Fracturas Intraarticulares/patología , Ligamentos Articulares/anatomía & histología , Masculino , Huesos del Metacarpo/diagnóstico por imagen , Huesos del Metacarpo/patología , Persona de Mediana Edad , Modelos Biológicos , Pulgar/diagnóstico por imagen , Pulgar/patología
12.
J Hand Surg Am ; 43(3): 248-259, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29502577

RESUMEN

The Andrew J. Weiland Medal is presented by the American Society for Surgery of the Hand to a midcareer researcher dedicated to advancing patient care in the field of hand surgery. The Weiland Medal for 2017 was presented to the author at the annual meeting of the American Society for Surgery of the Hand. The purpose of this article is to present current evidence on how biomechanics and morphology influence the pathophysiology of thumb carpometacarpal joint osteoarthritis.


Asunto(s)
Fenómenos Biomecánicos/fisiología , Articulaciones Carpometacarpianas/fisiopatología , Osteoartritis/fisiopatología , Pulgar/fisiopatología , Articulaciones Carpometacarpianas/diagnóstico por imagen , Fuerza de la Mano/fisiología , Humanos , Imagenología Tridimensional , Ligamentos Articulares/fisiología , Músculo Esquelético/diagnóstico por imagen , Atrofia Muscular/diagnóstico por imagen , Osteoartritis/diagnóstico por imagen , Pulgar/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Hueso Trapecio/diagnóstico por imagen , Hueso Trapecio/cirugía , Ultrasonografía , Microtomografía por Rayos X
13.
J Hand Surg Am ; 43(1): 33-38, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29029863

RESUMEN

PURPOSE: Thumb carpometacarpal (CMC) osteoarthritis (OA) represents a major source of functional morbidity. The effects of early CMC OA on loading and use patterns potentially lead to changes in local bone density and microarchitecture. Hounsfield units (HU), a quantitative attenuation coefficient obtained from computed tomography (CT) scans, have been shown to be a reliable marker of bone density. We hypothesized that early CMC OA is associated with lower local bone density about the CMC joint as assessed by HU. METHODS: We examined HU units from CT scans in 23 asymptomatic subjects and 91 patients with early CMC OA. The HU measurements were obtained within cancellous portions of the trapezium, capitate, first and third metacarpal bases, and distal radius. Linear regression models, with age and sex included as covariates, were used to assess the relationship between CMC OA and HU values at each anatomical site. RESULTS: Early OA patients had significantly lower HU than asymptomatic subjects within the trapezium (mean, 377 HU vs 436 HU) and first metacarpal bases (265 HU vs 324 HU). No significant group differences were noted at the capitate, third metacarpal, or distal radius. Male sex and younger age were associated with significantly higher HU at all the anatomical sites, except the first metacarpal base, where age had no significant effect. CONCLUSIONS: Subjects presenting with early CMC OA had significantly lower bone density as assessed with HU at the thumb CMC joint (trapezium and first metacarpal base). Early thumb CMC OA and discomfort may lead to diminished loading across the basal joint, producing focal disuse osteopenia. These findings in symptomatic early arthritis suggest a relationship between symptoms, functional use of the CMC joint, and local bone density. TYPE OF STUDY/LEVEL OF EVIDENCE: Diagnostic II.


Asunto(s)
Densidad Ósea/fisiología , Articulaciones Carpometacarpianas/fisiopatología , Osteoartritis/diagnóstico por imagen , Osteoartritis/fisiopatología , Pulgar/fisiopatología , Factores de Edad , Estudios de Casos y Controles , Femenino , Humanos , Modelos Lineales , Masculino , Huesos del Metacarpo/diagnóstico por imagen , Huesos del Metacarpo/fisiopatología , Persona de Mediana Edad , Factores Sexuales , Tomografía Computarizada por Rayos X , Hueso Trapecio/diagnóstico por imagen , Hueso Trapecio/fisiopatología
14.
Clin Orthop Relat Res ; 475(2): 522-528, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27822895

RESUMEN

BACKGROUND: Advanced thumb carpometacarpal (CMC) osteoarthritis (OA) can cause substantial impairment in hand function, from grasping heavy objects to fine manipulation of implements and tools. In the clinical setting, we commonly measure the grip strength of gross grasp with a hand dynamometer in patients with CMC OA. Cylindrical grasp, which requires more thumb contribution than gross grasp, is an alternative method of measuring grip strength and one that may provide insight into thumb-related conditions. Because gross grasp and cylindrical grasp use the thumb in different planes, measurement of gross grasp alone might underestimate impairment. Therefore, it is important to evaluate cylindrical grasp as well. To our knowledge this tool has yet to be examined in a population with early thumb CMC OA. QUESTIONS/PURPOSES: (1) Is cylindrical grasp and gross grasp strength reduced in subjects with early thumb CMC OA compared with asymptomatic control subjects? (2) What is the association of cylindrical and gross grasp to thumb CMC OA after adjusting for age, sex, and hand dominance? METHODS: We recruited 90 subjects with early symptomatic and radiographic thumb CMC OA and 38 asymptomatic healthy control subjects for this multisite controlled study. Demographic information, hand examination, comprehensive histories, plain film radiographs, and cylindrical and gross grasp strength data were collected on all 128 subjects. Mean grasp strength was calculated for cylindrical and gross grasp in the population with early CMC OA and the control population. A t-test was performed on cylindrical and gross grasp to evaluate the difference between the mean in the control and early CMC OA populations. We used separate linear regression models for the two types of grasp to further quantify the association of grasp with a diagnosis of early thumb CMC OA controlling for age, sex, and whether the subject used their dominant or nondominant hand in the study. RESULTS: Cylindrical grasp was weaker in the population with thumb CMC OA compared with healthy control subjects (6.3 ± 2.7 kg versus 8.4 ± 2.5 kg; mean difference, 2.1; 95% CI, 1.1-3.1; p < 0.001), but there was no difference in gross grasp force (29.6 ± 11.6 kg versus 31.4 ± 10.1 kg; mean difference, 1.7; 95% CI, -2.5 to 6.0; p = 0.425). When adjusting for age, sex, and handedness, cylindrical grasp reduction was related to CMC OA (ß = -2.3; standard error [SE], 0.46; p < 0.001) (Y-intercept = 8.2; SE, 1.8; R2 = 0.29), whereas gross grasp was not reduced in early thumb CMC OA (ß = -2.8; SE, 1.6; p = 0.072) (Y-intercept = 34.3; SE, 6.3; R2 = 0.48). CONCLUSIONS: A reduction in cylindrical grasp is associated with early symptomatic and radiographic CMC OA, whereas gross grasp is not associated with early thumb CMC OA, suggesting that cylindrical grasp may be a better tool to detect changes in thumb and hand function seen during early disease stages. CLINICAL RELEVANCE: Cylindrical grasp may serve as a more-sensitive measure for detecting early changes in early CMC OA. The associated decline in hand function also might provide an opportunity for measuring the effectiveness of treatment and intervention.


Asunto(s)
Articulaciones Carpometacarpianas/fisiopatología , Fuerza de la Mano/fisiología , Osteoartritis/fisiopatología , Pulgar/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad
15.
J Hand Surg Am ; 42(9): 749.e1-749.e7, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28648327

RESUMEN

PURPOSE: Congenital hand differences are infrequent phenomena, and their treatment represents a relatively small fraction of cases performed by hand surgeons. Little is known about the incidence of wound complications and acute postoperative problems given the relative rarity of these procedures. This study sought to characterize the incidence of complications within 30 days of surgery for congenital hand differences. METHODS: The National Surgical Quality Improvement Program (NSQIP) contains prospective data regarding 30-day morbidity from 64 pediatric centers across the United States. Data from all available years (2012-2014) were queried for Current Procedural Terminology (CPT) codes pertinent to the treatment of congenital hand differences. Bivariate statistics, Fisher exact tests and Poisson 95% confidence intervals (95% CI) were used to assess the incidence of complications and examine risk factors for these outcomes. RESULTS: We identified a total of 1,656 congenital hand cases that represented 4 different CPT codes, including surgery for simple syndactyly, complex syndactyly, and polydactyly. The overall incidence of complications was 2.2% (95% CI, 1.6%-3.1%; n = 37) with the most common complication being superficial surgical site infection (1.7%; 95% CI, 1.1%-2.4%) followed by related readmission (0.3%; 95% CI, 0.1%-0.7%). There was a higher incidence of complications observed in patients undergoing complex syndactyly repair (5.2% for complex syndactyly repair vs 2.3% for all others). CONCLUSIONS: The rate of acute complications following procedures to correct syndactyly and polydactyly is low, the most common of which is superficial surgical site infection. The incidence of acute complications may be helpful in counseling patients and families. We suggest that further research must prioritize collecting data on long-term functional outcomes. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic II.


Asunto(s)
Dedos/anomalías , Polidactilia/cirugía , Complicaciones Posoperatorias/epidemiología , Sindactilia/cirugía , Bases de Datos Factuales , Dedos/cirugía , Humanos , Incidencia , Mejoramiento de la Calidad , Estudios Retrospectivos , Factores de Riesgo , Infección de la Herida Quirúrgica/epidemiología , Estados Unidos/epidemiología
16.
Clin Orthop Relat Res ; 474(2): 557-61, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26493987

RESUMEN

BACKGROUND: The thumb carpometacarpal (CMC) joint orchestrates pinch in its various positions, and thumb CMC osteoarthritis (OA) is a major source of orthopaedic morbidity. Self-reported pain, weakness, and physical examination may not correspond to radiographic findings when diagnosing early thumb CMC OA. Weakness is a prominent feature of the disease, but little evidence exists to quantify self-reported loss of strength with time, or to compare weakness with that of a nonarthritic population during early disease. QUESTIONS/PURPOSES: We asked: (1) Is pinch strength in subjects with early thumb CMC OA less than that in asymptomatic control subjects; and (2) weakness in which pinch position (key, tripod, or tip pinch) has the strongest association with early OA diagnosis? METHODS: For this case-control study, we recruited 23 subjects who were asymptomatic and 91 with early OA for comprehensive history, physical examination, strength measurements, pain surveys, and radiographic evaluation. We used multivariate logistic regression to quantify the association between declining pinch strength and early OA diagnosis after controlling for age, sex, and BMI. This analysis was performed for three different pinch positions (key, tripod, and tip pinch) to evaluate which measurement was most closely associated with diagnosis. RESULTS: Pinch strength was less in patients with early thumb CMC OA. Key pinch had the most robust association with OA diagnosis, in which a 20% decrease in key pinch strength from the control subjects' baseline was associated with a 10% increase in the OA diagnosis (95% CI, 3%-16%; p = 0.004). This had a stronger association with OA diagnosis than tip pinch, in which a 20% decrease in strength was associated with a 6% increase in early CMC OA (95% CI, 1.0%-11%; p = 0.031). Tripod pinch also was associated to a lesser extent; a 20% reduction in tripod pinch led to a 5% increase in OA (95% CI, 1.3%-9%; p = 0.048). CONCLUSIONS: Decreasing pinch strength, especially key pinch, is associated with early CMC arthritis before the development of extensive radiographic disease. CLINICAL RELEVANCE: Weakness in pinch strength, especially key pinch, is an important feature in the pathogenesis of early CMC OA and may appear before radiographic disease is present or advanced. These findings suggest a role for intervention in early disease for promoting nonoperative joint protection and strengthening, and designing surgical procedures aimed to delay or prevent clinical and radiographic progression.


Asunto(s)
Articulaciones Carpometacarpianas/fisiopatología , Osteoartritis/diagnóstico , Fuerza de Pellizco , Pulgar/fisiopatología , Adulto , Anciano , Fenómenos Biomecánicos , Articulaciones Carpometacarpianas/diagnóstico por imagen , Estudios de Casos y Controles , Diagnóstico Precoz , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Osteoartritis/diagnóstico por imagen , Osteoartritis/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Radiografía , Rango del Movimiento Articular , Pulgar/diagnóstico por imagen
17.
J Am Acad Orthop Surg ; 23(6): 339-47, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26001426

RESUMEN

Gender differences exist in the presentation of musculoskeletal disease, and recognition of the differences between men and women's burden of disease and response to treatment is key in optimizing care of orthopaedic patients. The role of structural anatomy differences, hormones, and genetics are factors to consider in the analysis of differential injury and arthritic patterns between genders.


Asunto(s)
Enfermedades Musculoesqueléticas/fisiopatología , Femenino , Humanos , Masculino , Enfermedades Musculoesqueléticas/terapia , Relaciones Médico-Paciente , Factores Sexuales
19.
Instr Course Lect ; 64: 25-36, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25745892

RESUMEN

Osteoporosis is a worldwide epidemic, affecting more than 75 million people in the United States, Europe, and Japan. At a consensus conference in 1990, European and American leaders defined osteoporosis as a disease characterized by low bone mass, microarchitectural deterioration of bone tissue, and a resulting increase in fracture risk. In 2000, the National Institutes of Health modified this definition, describing osteoporosis as a skeletal disorder characterized by compromised bone strength and a predisposition for increased fracture risk. It was emphasized that bone strength, which is a more comprehensive concept than bone mass, integrates the concepts of both bone density and bone quality. As orthopaedic surgeons, recognizing osteoporosis and its healthcare implications is critical to optimize the musculoskeletal health of patients of all ages and both sexes.


Asunto(s)
Fijación de Fractura/métodos , Fracturas Osteoporóticas/cirugía , Humanos
20.
J Hand Surg Am ; 40(8): 1620-4, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25935517

RESUMEN

Juxta-articular giant cell tumors can pose major surgical challenges. Aggressive distal radius giant cell tumors often require complex reconstructive procedures that are associated with numerous complications. We present a case of a 25-year old man with a Campanacci grade 3 giant cell tumor of the distal radius that was successfully treated with denosumab without complex reconstructive procedures. At 3.5-year follow-up and 1-year drug free period, the patient remained asymptomatic without histologic evidence of recurrent tumor. With denosumab therapy, patients can potentially avoid surgery and achieve a successful outcome.


Asunto(s)
Conservadores de la Densidad Ósea/uso terapéutico , Neoplasias Óseas/tratamiento farmacológico , Denosumab/uso terapéutico , Tumor Óseo de Células Gigantes/tratamiento farmacológico , Radio (Anatomía) , Adulto , Neoplasias Óseas/patología , Tumor Óseo de Células Gigantes/patología , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA