Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 23(4)2023 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-36850867

RESUMEN

Compressive sensing (CS) has been proposed as a disruptive approach to developing a novel class of optical instrumentation used in diverse application domains. Thanks to sparsity as an inherent feature of many natural signals, CS allows for the acquisition of the signal in a very compact way, merging acquisition and compression in a single step and, furthermore, offering the capability of using a limited number of detector elements to obtain a reconstructed image with a larger number of pixels. Although the CS paradigm has already been applied in several application domains, from medical diagnostics to microscopy, studies related to space applications are very limited. In this paper, we present and discuss the instrumental concept, optical design, and performances of a CS imaging spectrometer for ultraviolet-visible (UV-Vis) stellar spectroscopy. The instrument-which is pixel-limited in the entire 300 nm-650 nm spectral range-features spectral sampling that ranges from 2.2 nm@300 nm to 22 nm@650 nm, with a total of 50 samples for each spectrum. For data reconstruction quality, the results showed good performance, measured by several quality metrics chosen from those recommended by CCSDS. The designed instrument can achieve compression ratios of 20 or higher without a significant loss of information. A pros and cons analysis of the CS approach is finally carried out, highlighting main differences with respect to a traditional system.

2.
Opt Express ; 18(11): 11622-49, 2010 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-20589022

RESUMEN

Recent investigations have induced relevant advancements of imaging interferometry, which is becoming a viable option for Earth remote sensing. Various research programs have chosen the Sagnac configuration for new imaging interferometers. Due to the growing diffusion of this technique, we have developed a self-contained theory for describing the signal produced by triangular FTSs and its optimal processing. We investigate the relevant disadvantages of multiplexing, and compare dispersive with FTS instruments. The paper addresses some methods for correcting the phase error, and the non-unitary transformation performed by a Sagnac interferometer. The effect of noise on spectral estimations is discussed.


Asunto(s)
Interferometría/instrumentación , Espectroscopía Infrarroja por Transformada de Fourier/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo
3.
Appl Opt ; 49(28): 5366-73, 2010 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-20885473

RESUMEN

Recent theoretical investigations have shown important radiometric disadvantages of interferential multiplexing in Fourier transform spectrometry that apparently can be applied even to coded aperture spectrometers. We have reexamined the methods of noninterferential multiplexing in order to assess their signal-to-noise ratio (SNR) performance, relying on a theoretical modeling of the multiplexed signals. We are able to show that quite similar SNR and radiometric disadvantages affect multiplex dispersive spectrometry. The effect of noise on spectral estimations is discussed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA