Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
2.
Ann Neurol ; 71(5): 719-23, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22522483

RESUMEN

The transcription factor EGR2 is expressed in Schwann cells, where it controls peripheral nerve myelination. Mutations of EGR2 have been found in patients with congenital hypomyelinating neuropathy or Charcot-Marie-Tooth disease type 1D. In a patient with congenital amyelinating neuropathy, we observed pathological abnormalities recapitulating the peripheral nervous system phenotype of homozygous Egr2-null mice. This patient, born from consanguineous parents, showed no EGR2 immunoreactivity in Schwann cells and harbored a homozygous 10.7-kilobase-long deletion encompassing a myelin-specific enhancer of EGR2. This regulatory mutation is the first genetic abnormality associated with congenital amyelinating neuropathy in humans.


Asunto(s)
Enfermedad de Charcot-Marie-Tooth/genética , Enfermedad de Charcot-Marie-Tooth/patología , Proteína 2 de la Respuesta de Crecimiento Precoz/genética , Elementos de Facilitación Genéticos/genética , Vaina de Mielina/patología , Secuencia de Bases , Femenino , Homocigoto , Humanos , Lactante , Recién Nacido , Datos de Secuencia Molecular , Linaje , Reacción en Cadena de la Polimerasa , Eliminación de Secuencia
3.
Clin Biochem ; 49(1-2): 111-6, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26282720

RESUMEN

BACKGROUND: Histamine (HA) is a small amine playing an important role in anaphylactic reactions. In order to identify and quantify HA in plasma matrix, different methods have been developed but present several disadvantages. Here, we developed an alternative method using liquid chromatography coupled with an ultra-high resolution and accurate mass instrument, Q Exactive™ (Thermo Fisher) (LCHRMS). METHODS: The method includes a protein precipitation of plasma samples spiked with HA-d4 as internal standard (IS). LC separation was performed on a C18 Accucore column (100∗2.1mm, 2.6µm) using a mobile phase containing nonafluoropentanoic acid (3nM) and acetonitrile with 0.1% (v/v) formic acid on gradient mode. Separation of analytes was obtained within 10min. Analysis was performed from full scan mode and targeted MS2 mode using a 5ppm mass window. Ion transitions monitored for targeted MS2 mode were 112.0869>95.0607m/z for HA and 116.1120>99.0855m/z for HA-d4. Calibration curves were obtained by adding standard calibration dilution at 1 to 180nM in TrisBSA. RESULTS: Elution of HA and IS occurred at 4.1min. The method was validated over a range of concentrations from 1nM to 100nM. The intra- and inter-run precisions were <15% for quality controls. Human plasma samples from 30 patients were analyzed by LCHRMS, and the results were highly correlated with those obtained using the gold standard radioimmunoassay (RIA) method. CONCLUSION: Overall, we demonstrate here that LCHRMS is a sensitive method for histamine quantification in biological human plasmas, suitable for routine use in medical laboratories. In addition, LCHRMS is less time-consuming than RIA, avoids the use of radioactivity, and could then be considered as an alternative quantitative method.


Asunto(s)
Cromatografía Liquida/métodos , Histamina/sangre , Espectrometría de Masas/métodos , Calibración , Humanos , Control de Calidad , Radioinmunoensayo , Estándares de Referencia
4.
J Pharm Biomed Anal ; 118: 307-314, 2016 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-26580828

RESUMEN

Histamine (HA) is one of the main immediate mediators involved in allergic reactions. HA plasma concentration is well correlated with the severity of vascular and respiratory signs of anaphylaxis. Consequently, plasma quantification of HA is useful to comfort the diagnosis of anaphylaxis. Currently, radioimmunoassay (RIA) is the gold standard method to quantify HA due to its high sensitivity, but it is time consuming, implicates specific formations and cautions for technicians, and produces hazardous radioactive wastes. The aim of this study was to compare two enzymatic immunoassays (EIA) and one in-house liquid chromatography high-resolution mass spectrometry method (LC-HRMS) with the gold standard method for HA quantification in plasma samples of patients suspected of anaphylaxis reactions. Ninety-two plasma samples were tested with the 4 methods (RIA, 2 EIA and LC-HRMS) for HA quantification. Fifty-eight samples displayed HA concentrations above the positive cut-off of 10nM evaluated by RIA, including 18 highly positive samples (>100 nM). This study shows that Immunotech(®) EIA and LC-HRMS concentrations were highly correlated with RIA values, in particular for samples with a HA concentration around the positive cut-off. In our hands, plasma concentrations obtained with the Demeditec Diagnostics(®) EIA correlated less with results obtained by RIA, and an underestimation of plasma HA levels led to a lack of sensitivity. In conclusion, this study demonstrates that Immunotech(®) EIA and LC-HRMS method could be used instead of RIA to assess plasma HA in human diagnostic use.


Asunto(s)
Histamina/sangre , Espectrometría de Masas en Tándem/métodos , Espectrometría de Masas en Tándem/normas , Cromatografía Liquida/métodos , Cromatografía Liquida/normas , Humanos , Técnicas para Inmunoenzimas , Espectrometría de Masas/métodos , Espectrometría de Masas/normas , Radioinmunoensayo/métodos , Radioinmunoensayo/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA