1.
Eur Heart J Suppl ; 25(Suppl E): E17-E24, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37234235

RESUMEN

Biventricular pacing (Biv) and left bundle branch area pacing (LBBAP) are methods of cardiac resynchronization therapy (CRT). Currently, little is known about how they differ in terms of ventricular activation. This study compared ventricular activation patterns in left bundle branch block (LBBB) heart failure patients using an ultra-high-frequency electrocardiography (UHF-ECG). This was a retrospective analysis including 80 CRT patients from two centres. UHF-ECG data were obtained during LBBB, LBBAP, and Biv. Left bundle branch area pacing patients were divided into non-selective left bundle branch pacing (NSLBBP) or left ventricular septal pacing (LVSP) and into groups with V6 R-wave peak times (V6RWPT) < 90 ms and ≥ 90 ms. Calculated parameters were: e-DYS (time difference between the first and last activation in V1-V8 leads) and Vdmean (average of V1-V8 local depolarization durations). In LBBB patients (n = 80) indicated for CRT, spontaneous rhythms were compared with Biv (39) and LBBAP rhythms (64). Although both Biv and LBBAP significantly reduced QRS duration (QRSd) compared with LBBB (from 172 to 148 and 152 ms, respectively, both P < 0.001), the difference between them was not significant (P = 0.2). Left bundle branch area pacing led to shorter e-DYS (24 ms) than Biv (33 ms; P = 0.008) and shorter Vdmean (53 vs. 59 ms; P = 0.003). No differences in QRSd, e-DYS, or Vdmean were found between NSLBBP, LVSP, and LBBAP with paced V6RWPTs < 90 and ≥ 90 ms. Both Biv CRT and LBBAP significantly reduce ventricular dyssynchrony in CRT patients with LBBB. Left bundle branch area pacing is associated with more physiological ventricular activation.

2.
Sensors (Basel) ; 22(5)2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35271057

RESUMEN

Pulse wave velocity is a commonly used parameter for evaluating arterial stiffness and the overall condition of the cardiovascular system. The main goal of this study was to establish a methodology to test and validate multichannel bioimpedance as a suitable method for whole-body evaluations of pulse waves. We set the proximal location over the left carotid artery and eight distal locations on both the upper and lower limbs. In this way, it was possible to simultaneously evaluate pulse wave velocity (PWV) in the upper and lower limbs and in the limbs via four extra PWV measurements. Data were acquired from a statistical group of 220 healthy subjects who were divided into three age groups. The data were then analysed. We found a significant dependency of aortic PWV on age in those values measured using the left carotid as the proximal. PWV values in the upper and lower limbs were found to have no significant dependency on age. In addition, the PWV in the left femoral artery shows comparable values to published already carotid-femoral values. Those findings prove the reliability of whole-body multichannel bioimpedance for pulse wave velocity evaluation and provide reference values for whole-body PWV measurement.


Asunto(s)
Envejecimiento , Análisis de la Onda del Pulso , Arterias Carótidas , Humanos , Extremidad Inferior , Análisis de la Onda del Pulso/métodos , Reproducibilidad de los Resultados
3.
J Cardiovasc Electrophysiol ; 32(5): 1385-1394, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33682277

RESUMEN

BACKGROUND: Right ventricular (RV) pacing causes delayed activation of remote ventricular segments. We used the ultra-high-frequency ECG (UHF-ECG) to describe ventricular depolarization when pacing different RV locations. METHODS: In 51 patients, temporary pacing was performed at the RV septum (mSp); further subclassified as right ventricular inflow tract (RVIT) and right ventricular outflow tract (RVOT) for septal inflow and outflow positions (below or above the plane of His bundle in right anterior oblique), apex, anterior lateral wall, and at the basal RV septum with nonselective His bundle or RBB capture (nsHBorRBBp). The timings of UHF-ECG electrical activations were quantified as left ventricular lateral wall delay (LVLWd; V8 activation delay) and RV lateral wall delay (RVLWd; V1 activation delay). RESULTS: The LVLWd was shortest for nsHBorRBBp (11 ms [95% confidence interval = 5-17]), followed by the RVIT (19 ms [11-26]) and the RVOT (33 ms [27-40]; p < .01 between all of them), although the QRSd for the latter two were the same (153 ms (148-158) vs. 153 ms (148-158); p = .99). RV apical capture not only had a longer LVLWd (34 ms (26-43) compared to mSp (27 ms (20-34), p < .05), but its RVLWd (17 ms (9-25) was also the longest compared to other RV pacing sites (mean values for nsHBorRBBp, mSp, anterior and lateral wall captures being below 6 ms), p < .001 compared to each of them. CONCLUSION: RVIT pacing produces better ventricular synchrony compared to other RV pacing locations with myocardial capture. However, UHF-ECG ventricular dysynchrony seen during RVIT pacing is increased compared to concomitant capture of basal septal myocytes and His bundle or proximal right bundle branch.


Asunto(s)
Ventrículos Cardíacos , Tabique Interventricular , Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Electrocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Contracción Miocárdica , Tabique Interventricular/diagnóstico por imagen
4.
J Cardiovasc Electrophysiol ; 31(1): 300-307, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31788894

RESUMEN

INTRODUCTION: The present study introduces a new ultra-high-frequency 14-lead electrocardiogram technique (UHF-ECG) for mapping ventricular depolarization patterns and calculation of novel dyssynchrony parameters that may improve the selection of patients and application of cardiac resynchronization therapy (CRT). METHODS: Components of the ECG in sixteen frequency bands within the 150 to 1000 Hz range were used to create ventricular depolarization maps. The maximum time difference between the UHF QRS complex centers of mass of leads V1 to V8 was defined as ventricular electrical dyssynchrony (e-DYS), and the duration at 50% of peak voltage amplitude in each lead was defined as the duration of local depolarization (Vd). Proof of principle measurements was performed in seven patients with left (left bundle branch block) and four patients with right bundle branch block (right bundle branch block) before and during CRT using biventricular and His-bundle pacing. RESULTS: The acquired activation maps reflect the activation sequence under the tested conditions. e-DYS decreased considerably more than QRS duration, during both biventricular pacing (-50% vs -8%) and His-bundle pacing (-77% vs -13%). While biventricular pacing slightly increased Vd, His-bundle pacing reduced Vd significantly (+11% vs -36%), indicating the contribution of the fast conduction system. Optimization of biventricular pacing by adjusting VV-interval showed a decrease of e-DYS from 102 to 36 ms with only a small Vd increase and QRS duration decrease. CONCLUSIONS: The UHF-ECG technique provides novel information about electrical activation of the ventricles from a standard ECG electrode setup, potentially improving the selection of patients for CRT and application of CRT.


Asunto(s)
Fascículo Atrioventricular/fisiopatología , Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca , Electrocardiografía , Insuficiencia Cardíaca/terapia , Frecuencia Cardíaca , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/fisiopatología , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Valor Predictivo de las Pruebas , Prueba de Estudio Conceptual , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda , Función Ventricular Derecha
5.
J Card Fail ; 23(7): 558-562, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28408305

RESUMEN

BACKGROUND: Patients with atrial fibrillation (AF) have an increased risk of diastolic dysfunction and heart failure. The purpose of this study was to identify independent predictors of early (ie, only exercise-induced) heart failure with preserved ejection fraction (HFpEF) and to describe the prevalence of early HFpEF among patients with paroxysmal AF. METHODS AND RESULTS: One hundred patients with paroxysmal AF and preserved left ventricular ejection fraction (LVEF) underwent catheterization for left atrial pressure (LAP) measurements at rest and at the peak of arm exercise (LAP-exe). Based on resting and exercise LAP values, the patients were divided into 3 groups. Sixty-one patients had no evidence of HFpEF (LAP at rest ≤15 mm Hg, LAP-exe <25 mm Hg). Twenty-five subjects had early HFpEF (LAP at rest ≤15 mm Hg, LAP-exe ≥25 mm Hg, prevalence 25%). Fourteen patients already had HFpEF at rest (LAP at rest >15 mm Hg). Multivariate exact logistic regression analysis identified age ≥58 years, LAP at rest ≥11 mm Hg, and peak systolic mitral annular velocity ≤9.3 cm/s to be independent predictors of early HFpEF. CONCLUSIONS: In patients with paroxysmal AF and preserved LVEF, there appears to be a clinically significant prevalence of early HFpEF.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/epidemiología , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/epidemiología , Volumen Sistólico/fisiología , Anciano , Fibrilación Atrial/fisiopatología , Estudios de Cohortes , Diagnóstico Precoz , Femenino , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevalencia , Estudios Prospectivos
6.
Echocardiography ; 34(1): 78-86, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27779336

RESUMEN

BACKGROUND: Noninvasive diagnosis of exercise-induced elevation of left ventricular filling pressure is difficult and remains unsatisfactory. The aim of this study was to assess the accuracy of the ratio of early diastolic transmitral (E) to mitral annular (e') velocity and to determine new parameters or parameter combinations with the ability to predict exercise-induced left atrial pressure (LAP) elevation. METHODS AND RESULTS: Eighty patients with paroxysmal atrial fibrillation (AF) referred for catheter AF ablation underwent simultaneous exercise echocardiography and direct invasive LAP measurements, as well as a resting and postexercise biomarker analysis. Exercise E/e' ≥8.85 predicted exercise LAP ≥20 mm Hg with 61.5% sensitivity and 88.9% specificity (area under the curve [AUC], 0.76). Of all of the individual parameters tested, the best prediction was achieved with exercise E/s' (s'=peak systolic mitral annular velocity) ≥8.75 (sensitivity, 88.5%; specificity, 64.8%; positive predictive value, 54.8%; negative predictive value, 92.1%; AUC, 0.84). However, the combination of exercise E/A (A = late diastolic transmitral flow velocity) ≥1.22 + exercise E/e' ≥8.85 + exercise s'≤11.05 cm/s provided the most precise prediction of exercise LAP elevation (sensitivity, 84.6%; specificity, 79.6%; positive predictive value, 66.7%; negative predictive value, 91.5%; AUC, 0.90). CONCLUSIONS: Exercise E/e', when used as a sole parameter, was not sufficiently reliable to predict exercise-induced elevation of LAP. The application of a multivariate-adjusted combination of parameters appeared to be the preferable approach for the noninvasive prediction of exercise LAP elevation.


Asunto(s)
Ecocardiografía/métodos , Ejercicio Físico/fisiología , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología , Presión Ventricular/fisiología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Velocidad del Flujo Sanguíneo , Diástole , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Sístole
7.
J Electrocardiol ; 49(6): 902-906, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27590215

RESUMEN

Ambulatory monitoring represents an effective tool for the assessment of silent and transient myocardial ischemia during routine daily activities. Incidence of silent ischemia can provide important prognostic information about patients with coronary artery disease or acute coronary syndrome, as well as about post-myocardial infarction patients. The current technological progress enables development of powerful and miniaturized wearable devices for Holter monitoring. Higher sampling rates, dynamic range, and extended computational and storage capacity allow for considering of more complex methodological solutions such as high-frequency QRS analysis for diagnosing myocardial ischemia. Implementation of suitable methodologies for advanced detection of myocardial ischemia into modern ambulatory monitoring devices creates the potential of making the ambulatory myocardial ischemia monitoring a valuable diagnostic tool in clinical practice.


Asunto(s)
Algoritmos , Diagnóstico por Computador/métodos , Electrocardiografía Ambulatoria/métodos , Determinación de la Frecuencia Cardíaca/métodos , Isquemia Miocárdica/diagnóstico , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
8.
Aust Crit Care ; 28(4): 203-7, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26530412

RESUMEN

OBJECTIVE: Pulse pressure variations (PPV) are mainly influenced by ventilation. The impact of sedation on PPV is not known. The aim of the study was to test the influence of sedation on pulse pressure variation in mechanically ventilated critically ill patients and to compare PPV in critically ill and brain dead patients. Beside the absolute value of PPV, the adjusted values of pulse pressure were used to eliminate influence of ventilation. DESIGN AND INTERVENTION: Mechanically ventilated patients received four different breath frequencies. At each frequency airway pressure was adjusted to keep the end-tidal CO2 stable. In critically ill patients the frequencies were applied at basal (bispectral index - BIS median 38) and deeper sedation (BIS 29). MAIN OUTCOME MEASURES: Simultaneous haemodynamic and respiratory data including oesophageal pressure were recorded, adjusted PPV were calculated as PPV/VT, PPV/dPair, PPV/dPes where VT is tidal volume, dPair and dPes are airway and oesophageal driving pressures. SETTING: University Hospital, ICU. PARTICIPANTS: 30 critically ill and 23 patients with a diagnosis of brain death. RESULTS: The pulse pressure variation did not change significantly during deep sedation compared to basal sedation (median 10.3 vs 10.9%) whereas PPV/dPair increased from 0.7 to 0.8%/cmH2O and PPV/dPes from 1.9%/cmH2O to 2.4%/cmH2O (p=0.04). Patients with a diagnosis of brain death had higher PPV and adjusted PPV than critically ill patients. CONCLUSION: Deeper sedation increases values of adjusted pulse pressure variation.


Asunto(s)
Presión Sanguínea/fisiología , Enfermedad Crítica , Respiración Artificial , Anciano , Muerte Encefálica , Femenino , Hemodinámica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Respiración con Presión Positiva
9.
J Electrocardiol ; 47(6): 863-8, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25175174

RESUMEN

BACKGROUND: Repolarization processes in female and male are different. This study provided pilot data on automatic measurements of QT intervals in heart transplant (HT) recipients stratified according to the sex of the recipient and the donor. METHODS AND RESULTS: The following groups were analyzed: Group A-20 males with male heart, group B-14 females with male heart, group C-13 females with female heart, group D-11 males with female heart, group E-20 healthy males, and group F-20 healthy females. Twelve-lead electrocardiograms were digitally captured during autonomic provocative test of five postural 8-minute stages-supine, unsupported sitting, supine, unsupported standing, and supine. Fridericia formula was used for heart rate correction together with a generic correction for QT/RR hysteresis. Neither female nor male HT recipients exhibit any differences in QTc interval duration related to the sex of the donor. There was, however, a trend towards longer QTc intervals in female HT recipients compared to male HT recipients irrespective of the sex of the donor. The QTc differences between healthy control females and males were highly statistically significant proving the assay sensitivity of the study. CONCLUSION: The available pilot data suggest that in HT patients, the sex of the donor has little influence on the QTc interval of the transplanted heart.


Asunto(s)
Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Frecuencia Cardíaca , Trasplante de Corazón/estadística & datos numéricos , Donantes de Tejidos/estadística & datos numéricos , Receptores de Trasplantes/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , República Checa/epidemiología , Electrocardiografía Ambulatoria/estadística & datos numéricos , Femenino , Insuficiencia Cardíaca/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Caracteres Sexuales , Distribución por Sexo
10.
Sci Rep ; 14(1): 5681, 2024 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-38454102

RESUMEN

From precordial ECG leads, the conventional determination of the negative derivative of the QRS complex (ND-ECG) assesses epicardial activation. Recently we showed that ultra-high-frequency electrocardiography (UHF-ECG) determines the activation of a larger volume of the ventricular wall. We aimed to combine these two methods to investigate the potential of volumetric and epicardial ventricular activation assessment and thereby determine the transmural activation sequence. We retrospectively analyzed 390 ECG records divided into three groups-healthy subjects with normal ECG, left bundle branch block (LBBB), and right bundle branch block (RBBB) patients. Then we created UHF-ECG and ND-ECG-derived depolarization maps and computed interventricular electrical dyssynchrony. Characteristic spatio-temporal differences were found between the volumetric UHF-ECG activation patterns and epicardial ND-ECG in the Normal, LBBB, and RBBB groups, despite the overall high correlations between both methods. Interventricular electrical dyssynchrony values assessed by the ND-ECG were consistently larger than values computed by the UHF-ECG method. Noninvasively obtained UHF-ECG and ND-ECG analyses describe different ventricular dyssynchrony and the general course of ventricular depolarization. Combining both methods based on standard 12-lead ECG electrode positions allows for a more detailed analysis of volumetric and epicardial ventricular electrical activation, including the assessment of the depolarization wave direction propagation in ventricles.


Asunto(s)
Electrocardiografía , Ventrículos Cardíacos , Humanos , Estudios Retrospectivos , Electrocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Bloqueo de Rama/diagnóstico , Arritmias Cardíacas
11.
Exp Clin Cardiol ; 18(2): 63-72, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23940422

RESUMEN

OBJECTIVES: At present, there are conflicting data on the ability of echocardiographic parameters to predict the exercise-induced elevation of left ventricular (LV) filling pressure. The purpose of the present study was to validate the ratio of early diastolic transmitral (E) to mitral annular velocity (e') obtained at peak exercise in its capacity to determine the exercise-induced elevation of pulmonary capillary wedge pressure (PCWP) and to reveal new noninvasive parameters with such capacity. METHODS: Sixty-one patients who had undergone heart transplantation with normal LV ejection fraction underwent simultaneous exercise echocardiography and right heart catheterization. RESULTS: In 50 patients with a normal PCWP at rest, exercise E/e' ≥8.5 predicted exercise PCWP ≥25 mmHg with a sensitivity of 64.3% and a specificity of 84.2% (area under the curve [AUC]=0.74). A comparable or slightly better prediction was achieved by exercise E/peak systolic mitral annular velocity (s') ≥11.0 (sensitivity 79.3%; specificity 57.9%; AUC=0.75) and exercise E/LV systolic longitudinal strain rate ≤-105 cm (sensitivity 78.9%; specificity 78.6%; AUC=0.87). Combined, exercise E/s' and exercise E/e' resulted in a trend toward a slightly more precise prediction (sensitivity 53.6%; specificity 89.5%; AUC=0.78) than did either variable alone. CONCLUSIONS: Exercise E/e', used as a sole parameter, is not sufficiently precise to predict the exercise-induced elevation of PCWP. Exercise E/s', E/LV systolic longitudinal strain rate or combinations of these parameters may represent further promising possibilities for predicting exercise PCWP elevation.

12.
Front Cardiovasc Med ; 10: 1140988, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37034324

RESUMEN

Background: Left bundle branch pacing (LBBP) produces delayed, unphysiological activation of the right ventricle. Using ultra-high-frequency electrocardiography (UHF-ECG), we explored how bipolar anodal septal pacing with direct LBB capture (aLBBP) affects the resultant ventricular depolarization pattern. Methods: In patients with bradycardia, His bundle pacing (HBP), unipolar nonselective LBBP (nsLBBP), aLBBP, and right ventricular septal pacing (RVSP) were performed. Timing of local ventricular activation, in leads V1-V8, was displayed using UHF-ECG, and electrical dyssynchrony (e-DYS) was calculated as the difference between the first and last activation. Durations of local depolarizations were determined as the width of the UHF-QRS complex at 50% of its amplitude. Results: aLBBP was feasible in 63 of 75 consecutive patients with successful nsLBBP. aLBBP significantly improved ventricular dyssynchrony (mean -9 ms; 95% CI (-12;-6) vs. -24 ms (-27;-21), ), p < 0.001) and shortened local depolarization durations in V1-V4 (mean differences -7 ms to -5 ms (-11;-1), p < 0.05) compared to nsLBBP. aLBBP resulted in e-DYS -9 ms (-12; -6) vs. e-DYS 10 ms (7;14), p < 0.001 during HBP. Local depolarization durations in V1-V2 during aLBBP were longer than HBP (differences 5-9 ms (1;14), p < 0.05, with local depolarization duration in V1 during aLBBP being the same as during RVSP (difference 2 ms (-2;6), p = 0.52). Conclusion: Although aLBBP improved ventricular synchrony and depolarization duration of the septum and RV compared to unipolar nsLBBP, the resultant ventricular depolarization was still less physiological than during HBP.

13.
Ann Noninvasive Electrocardiol ; 17(4): 323-30, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23094878

RESUMEN

BACKGROUND: The patients with the long QT syndrome type-1 (LQT-1) have an impaired adaptation of the QT interval to heart rate changes. Yet, the description of the dynamic QT-RR coupling in genotyped LQT-1 has never been thoroughly investigated. METHOD: We propose a method to model the dynamic QT-RR coupling by defining a transfer function characterizing the relationship between a QT interval and its previous RR intervals measured from ambulatory Holter recordings. Three parameters are used to characterize the QT-RR coupling: a fast gain (Gain(F) ), a slow gain (Gain(L) ), and a time constant (τ). We investigated the values of these parameters across genders, and in genotyped LQT-1 patients with normal QTc interval duration (QTc < 470 ms). RESULTS: The QT-RR dynamic profiles are significantly different between LQT-1 patients (97) and controls (154): LQT-1 have longer QTc interval (453 ± 35 vs. 384 ± 26 ms, P < 0.0001), and an increased dependency of the QT interval to previous RR changes revealed by a larger Gain(L) (0.22 ± 0.06 vs. 0.18 ± 0.07, P < 0.0001) and Gain(F) (0.05 ± 0.02 vs. 0.03 ± 0.01, P < 0.0001). Importantly, LQT-1 patients have a faster QT dynamic response to previous RR changes described by τ: 122 ± 44 vs. 172 ± 92 beats (P < 0.0001). This faster QT dynamic response of the QT-RR dynamic coupling remained in LQT-1 patients with QTc in a normal range (<430 ms). CONCLUSIONS: The measurement of QT-RR dynamic coupling could be used in patients suspected to carry a concealed form of the LQT-1 syndrome, or to provide insights into the types of arrhythmogenic triggers a patient may be prone to.


Asunto(s)
Electrocardiografía Ambulatoria/métodos , Síndrome de QT Prolongado/diagnóstico , Síndrome de QT Prolongado/fisiopatología , Adaptación Fisiológica , Adulto , Ritmo Circadiano , Estudios de Cohortes , Electrocardiografía Ambulatoria/estadística & datos numéricos , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Valores de Referencia , Adulto Joven
14.
Clin Cardiol ; 45(4): 386-390, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35194820

RESUMEN

BACKGROUND: Obstructive sleep apnea (OSA) imposes an afterload burden on the left ventricle and increases the pressure gradient across the aortic wall. Thus, OSA may increase the risk for aortic dissection (AD). METHODS: This study enrolled 40 subjects with acute AD from four institutions; 37 completed the modified Berlin Questionnaire and 31 underwent attended overnight polysomnography. Aortic diameter was measured on a computed tomography scan at seven locations from the sinotubular junction to the diaphragm. RESULTS: Twenty-seven subjects had type A dissection; 13 had type B. In those who had polysomnography apnea-hypopnea index (AHI) ranged from 0.7 to 89. Prevalence of OSA (AHI ≥ 5) was 61%. Nocturnal presentation (10 p.m.-7 a.m.) did not differ by presence/absence of OSA. The modified Berlin Questionnaire was not predictive of the presence of OSA. Among type A subjects with polysomnography (n = 23), aortic diameters at all locations were greater in the OSA group though differences were not statistically significant. Summating aortic diameters at the seven locations also yielded a numerically larger mean value in the OSA group versus the non-OSA group. CONCLUSIONS: In this sample of patients with acute dissection, OSA was prevalent but was not associated with a nocturnal presentation. The presence of underlying OSA may be associated with larger aortic diameters at the time of dissection compared to patients without OSA. Though differences did not meet statistical significance the current series is limited by small numbers.


Asunto(s)
Disección Aórtica , Apnea Obstructiva del Sueño , Disección Aórtica/diagnóstico , Disección Aórtica/epidemiología , Humanos , Polisomnografía , Prevalencia , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/epidemiología , Encuestas y Cuestionarios
15.
Sci Rep ; 11(1): 11469, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-34075135

RESUMEN

The study introduces and validates a novel high-frequency (100-400 Hz bandwidth, 2 kHz sampling frequency) electrocardiographic imaging (HFECGI) technique that measures intramural ventricular electrical activation. Ex-vivo experiments and clinical measurements were employed. Ex-vivo, two pig hearts were suspended in a human-torso shaped tank using surface tank electrodes, epicardial electrode sock, and plunge electrodes. We compared conventional epicardial electrocardiographic imaging (ECGI) with intramural activation by HFECGI and verified with sock and plunge electrodes. Clinical importance of HFECGI measurements was performed on 14 patients with variable conduction abnormalities. From 3 × 4 needle and 108 sock electrodes, 256 torso or 184 body surface electrodes records, transmural activation times, sock epicardial activation times, ECGI-derived activation times, and high-frequency activation times were computed. The ex-vivo transmural measurements showed that HFECGI measures intramural electrical activation, and ECGI-HFECGI activation times differences indicate endo-to-epi or epi-to-endo conduction direction. HFECGI-derived volumetric dyssynchrony was significantly lower than epicardial ECGI dyssynchrony. HFECGI dyssynchrony was able to distinguish between intraventricular conduction disturbance and bundle branch block patients.


Asunto(s)
Diagnóstico por Imagen , Electrocardiografía , Sistema de Conducción Cardíaco , Ventrículos Cardíacos , Animales , Sistema de Conducción Cardíaco/diagnóstico por imagen , Sistema de Conducción Cardíaco/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Porcinos
16.
Front Cardiovasc Med ; 8: 787414, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34950718

RESUMEN

Background: Three different ventricular capture types are observed during left bundle branch pacing (LBBp). They are selective LBB pacing (sLBBp), non-selective LBB pacing (nsLBBp), and myocardial left septal pacing transiting from nsLBBp while decreasing the pacing output (LVSP). Study aimed to compare differences in ventricular depolarization between these captures using ultra-high-frequency electrocardiography (UHF-ECG). Methods: Using decremental pacing voltage output, we identified and studied nsLBBp, sLBBp, and LVSP in patients with bradycardia. Timing of ventricular activations in precordial leads was displayed using UHF-ECGs, and electrical dyssynchrony (e-DYS) was calculated as the difference between the first and last activation. The durations of local depolarizations (Vd) were determined as the width of the UHF-QRS complex at 50% of its amplitude. Results: In 57 consecutive patients, data were collected during nsLBBp (n = 57), LVSP (n = 34), and sLBBp (n = 23). Interventricular dyssynchrony (e-DYS) was significantly lower during LVSP -16 ms (-21; -11), than nsLBBp -24 ms (-28; -20) and sLBBp -31 ms (-36; -25). LVSP had the same V1d-V8d as nsLBBp and sLBBp except for V3d, which during LVSP was shorter than sLBBp; the mean difference -9 ms (-16; -1), p = 0.01. LVSP caused less interventricular dyssynchrony and the same or better local depolarization durations than nsLBBp and sLBBp irrespective of QRS morphology during spontaneous rhythm or paced QRS axis. Conclusions: In patients with bradycardia, LVSP in close proximity to LBB resulted in better interventricular synchrony than nsLBBp and sLBBp and did not significantly prolong depolarization of the left ventricular lateral wall.

17.
Heart Rhythm ; 18(8): 1281-1289, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33930549

RESUMEN

BACKGROUND: Nonselective His-bundle pacing (nsHBp), nonselective left bundle branch pacing (nsLBBp), and left ventricular septal myocardial pacing (LVSP) are recognized as physiological pacing techniques. OBJECTIVE: The purpose of this study was to compare differences in ventricular depolarization between these techniques using ultra-high-frequency electrocardiography (UHF-ECG). METHODS: In patients with bradycardia, nsHBp, nsLBBp (confirmed concomitant left bundle branch [LBB] and myocardial capture), and LVSP (pacing in left ventricular [LV] septal position without proven LBB capture) were performed. Timings of ventricular activations in precordial leads were displayed using UHF-ECG, and electrical dyssynchrony (e-DYS) was calculated as the difference between the first and last activation. Duration of local depolarization (Vd) was determined as width of the UHF-QRS complex at 50% of its amplitude. RESULTS: In 68 patients, data were collected during nsLBBp (35), LVSP (96), and nsHBp (55). nsLBBp resulted in larger e-DYS than did LVSP and nsHBp [- 24 ms (-28;-19) vs -12 ms (-16;-9) vs 10 ms (7;14), respectively; P <.001]. nsLBBp produced similar values of Vd in leads V5-V8 (36-43 ms vs 38-43 ms; P = NS in all leads) but longer Vd in leads V1-V4 (47-59 ms vs 41-44 ms; P <.05) as nsHBp. LVSP caused prolonged Vd in leads V1-V8 compared to nsHBp and longer Vd in leads V5-V8 compared to nsLBBp (44-51 ms vs 36-43 ms; P <.05) regardless of R-wave peak time in lead V5 or QRS morphology in lead V1 present during LVSP. CONCLUSION: nslbbp preserves physiological LV depolarization but increases interventricular electrical dyssynchrony. LV lateral wall depolarization during LVSP is prolonged, but interventricular synchrony is preserved.


Asunto(s)
Fascículo Atrioventricular/fisiopatología , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Ventrículos Cardíacos/fisiopatología , Función Ventricular Izquierda/fisiología , Tabique Interventricular/fisiopatología , Anciano , Bloqueo de Rama/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos
18.
IEEE Trans Biomed Eng ; 67(10): 2721-2734, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-31995473

RESUMEN

OBJECTIVE: Nowadays, methods for ECG quality assessment are mostly designed to binary distinguish between good/bad quality of the whole signal. Such classification is not suitable to long-term data collected by wearable devices. In this paper, a novel approach to estimate long-term ECG signal quality is proposed. METHODS: The real-time quality estimation is performed in a local time window by calculation of continuous signal-to-noise ratio (SNR) curve. The layout of the data quality segments is determined by analysis of SNR waveform. It is distinguished between three levels of ECG signal quality: signal suitable for full wave ECG analysis, signal suitable only for QRS detection, and signal unsuitable for further processing. RESULTS: The SNR limits for reliable QRS detection and full ECG waveform analysis are 5 and 18 dB respectively. The method was developed and tested using synthetic data and validated on real data from wearable device. CONCLUSION: The proposed solution is a robust, accurate and computationally efficient algorithm for annotation of ECG signal quality that will facilitate the subsequent tailored analysis of ECG signals recorded in free-living conditions. SIGNIFICANCE: The field of long-term ECG signals self-monitoring by wearable devices is swiftly developing. The analysis of massive amount of collected data is time consuming. It is advantageous to characterize data quality in advance and thereby limit consequent analysis to useable signals.


Asunto(s)
Procesamiento de Señales Asistido por Computador , Dispositivos Electrónicos Vestibles , Algoritmos , Electrocardiografía , Relación Señal-Ruido , Condiciones Sociales
19.
Heart Rhythm ; 17(4): 607-614, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31805370

RESUMEN

BACKGROUND: Right ventricular myocardial pacing leads to nonphysiological activation of heart ventricles. Contrary to this, His bundle pacing preserves their fast activation. Ultra-high-frequency electrocardiography (UHF-ECG) is a novel tool for ventricular depolarization assessment. OBJECTIVE: The purpose of this study was to describe UHF-ECG depolarization patterns during myocardial and His bundle pacing. METHODS: Forty-six patients undergoing His bundle pacing to treat bradycardia and spontaneous QRS complexes without bundle branch block were included. UHF-ECG recordings were performed during spontaneous rhythm, pure myocardial para-Hisian capture, and His bundle capture. QRS duration, QRS area, depolarization time in specific leads, and the UHF-ECG-derived ventricular dyssynchrony index were calculated. RESULTS: One hundred thirty-three UHF-ECG recordings were performed in 46 patients (44 spontaneous rhythm, 28 selective His bundle, 43 nonselective His bundle, and 18 myocardial capture). The mean QRS duration was 117 ms for spontaneous rhythm, 118 ms for selective, 135 ms for nonselective, and 166 ms for myocardial capture (P < .001 for nonselective and myocardial capture compared to each of the other types of ventricular activation). The calculated dyssynchrony index was shortest during spontaneous rhythm (12 ms; P = .02 compared to selective and P = .09 compared to nonselective), and it did not differ between selective and nonselective His bundle capture (16 vs 15 ms; P > .99) and was longest during myocardial capture of the para-Hisian area (37 ms; P < .001 compared to each of the other types of ventricular activation). CONCLUSION: In patients without bundle branch block, both types of His bundle, but not myocardial, capture preserve ventricular electrical synchrony as measured using UHF-ECG.


Asunto(s)
Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Frecuencia Cardíaca/fisiología , Función Ventricular Izquierda/fisiología , Función Ventricular Derecha/fisiología , Anciano , Fascículo Atrioventricular/fisiopatología , Bloqueo de Rama/fisiopatología , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino
20.
PLoS One ; 14(5): e0217097, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31150418

RESUMEN

INTRODUCTION: Cardiac resynchronization therapy (CRT) is an effective treatment that reduces mortality and improves cardiac function in patients with left bundle branch block (LBBB). However, about 30% of patients passing the current criteria do not benefit or benefit only a little from CRT. Three predictors of benefit based on different ECG properties were compared: 1) "strict" left bundle branch block classification (SLBBB); 2) QRS area; 3) ventricular electrical delay (VED) which defines the septal-lateral conduction delay. These predictors have never been analyzed concurrently. We analyzed the relationship between them on a subset of 602 records from the MADIT-CRT trial. METHODS & RESULTS: SLBBB classification was performed by two experts; QRS area and VED were computed fully automatically. High-frequency QRS (HFQRS) maps were used to inspect conduction abnormalities. The correlation between SLBBB and other predictors was R = 0.613, 0.523 and 0.390 for VED, QRS area in Z lead, and QRS duration, respectively. Scatter plots were used to pick up disagreement between the predictors. The majority of SLBBB subjects- 295 of 330 (89%)-are supposed to respond positively to CRT according to the VED and QRS area, though 93 of 272 (34%) non-SLBBB should also benefit from CRT according to the VED and QRS area. CONCLUSION: SLBBB classification is limited by the proper setting of cut-off values. In addition, it is too "strict" and excludes patients that may benefit from CRT therapy. QRS area and VED are clearly defined parameters. They may be used to optimize biventricular stimulation. Detailed analysis of conduction irregularities with CRT optimization should be based on HFQRS maps.


Asunto(s)
Bloqueo de Rama/terapia , Dispositivos de Terapia de Resincronización Cardíaca/normas , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos , Electrocardiografía/normas , Potenciales de Acción , Bloqueo de Rama/fisiopatología , Cardioversión Eléctrica , Frecuencia Cardíaca , Humanos , Valor Predictivo de las Pruebas , Resultado del Tratamiento , Función Ventricular Izquierda