Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Arthroplasty ; 32(3): 996-1000, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27776907

RESUMEN

BACKGROUND: Currently, no serum metal ion threshold exists to identify adverse tissue reactions in total hip arthroplasty (THA) patients with taper corrosion. Our study aims to investigate the sensitivity and specificity of serum metal ions in detecting taper corrosion related pseudotumors in patients with dual taper modular THA. METHODS: A total of 148 patients with dual taper modular THA were investigated: (1) 90 patients with pseudotumors detected with metal artifact reduction sequence-magnetic resonance imaging (MARS-MRI) and (2) 58 patients without pseudotumors on MARS-MRI. Receiver operating characteristic curves were constructed to determine the sensitivity and specificity using different metal ion thresholds. The severity of intraoperative tissue damage was correlated with preoperative metal ion levels. RESULTS: Pseudotumor was associated with higher cobalt (5.0 µg/L vs 3.7 µg/L, P < .01) and Co/Cr ratio (6.0 vs 3.7, P < .01). The sensitivity and specificity for cobalt level of 2.8 µg/L and Co/Cr ratio of 3.8 in detecting taper corrosion-related pseudotumors on MARS-MRI was 88% and 32% and 70% and 50%, respectively. Higher intraoperative tissue damage grades demonstrated significantly higher Co/Cr ratios (8.6 vs 3.4, P = .03). CONCLUSION: Although metal ion levels alone should not be relied on as the sole parameter to determine revision surgery, cobalt level >2.8 µg/L and the Co/Cr ratio >3.8 are useful clinical diagnostic adjuncts in the systematic clinical evaluation for taper corrosion-related adverse tissue reactions in patients with dual modular taper THA.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Granuloma de Células Plasmáticas/sangre , Granuloma de Células Plasmáticas/etiología , Prótesis de Cadera/efectos adversos , Metales/sangre , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Cromo/sangre , Cobalto/sangre , Corrosión , Femenino , Granuloma de Células Plasmáticas/diagnóstico , Humanos , Iones , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Curva ROC , Reoperación , Estudios Retrospectivos , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
2.
J Arthroplasty ; 31(9): 1997-2003, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-26994651

RESUMEN

BACKGROUND: An accurate diagnosis of periprosthetic joint infection (PJI) is critical as treatment of the infected total hip arthroplasty differs from aseptic failure. The clinical presentation of PJI may mimic symptoms of taper corrosion. Our aim was to evaluate the utility of serum inflammatory markers and synovial fluid white blood cell (WBC)/differential counts in diagnosis of PJI in failed dual taper total hip arthroplasty due to taper corrosion. METHODS: We retrospectively reviewed 62 dual taper modular stem patients who underwent revision surgery for symptomatic adverse local tissue reaction due to taper corrosion. All patients had preoperative hip synovial aspirations, serum inflammatory markers, metal ion levels, and intraoperative cultures. Using Musculoskeletal Infection Society PJI criteria, we divided the cohort into infected and noninfected groups. Receiver-operating characteristic curves were constructed to determine the relationship and optimal cutoff values for erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and synovial fluid counts. RESULTS: Infection group had significantly higher mean ESR (P = .002), CRP (P = .01), synovial fluid WBC (P < .001), and neutrophil percentage (P = .02). Cobalt levels were significantly elevated in noninfection group (P = .02). Using receiver-operating characteristic curve analysis, the most ideal tests for diagnosis of PJI were synovial fluid WBC (area under the curve = 86%, optimal cutoff 730 WBC/uL) and neutrophil percentage (area under the curve = 83%, optimal cutoff 65%). ESR and CRP thresholds of 22 mm/h and 3 mg/L demonstrated 57% sensitivity and 95% specificity and 29% sensitivity and 93% specificity for detection of PJI, respectively. CONCLUSION: Our study suggests that ESR and CRP are useful in excluding PJI in dual taper modular implants with corrosion, whereas both synovial WBC count and neutrophil percentage are useful markers for diagnosing infection.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Inflamación/sangre , Líquido Sinovial/química , Adulto , Anciano , Artritis Infecciosa/cirugía , Biomarcadores/sangre , Sedimentación Sanguínea , Proteína C-Reactiva/análisis , Corrosión , Femenino , Humanos , Recuento de Leucocitos , Masculino , Persona de Mediana Edad , Neutrófilos , Infecciones Relacionadas con Prótesis/cirugía , Curva ROC , Reoperación , Estudios Retrospectivos , Sensibilidad y Especificidad
3.
J Arthroplasty ; 31(7): 1549-54, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26895822

RESUMEN

BACKGROUND: Modular dual taper femoral neck designs have been associated with taper corrosion requiring revision surgery. However, outcomes after revision dual taper total hip arthroplasty in patients with symptomatic adverse local tissue reaction due to taper corrosion remain largely unknown. METHODS: A total of 198 revision surgeries in 187 patients with dual taper femoral stem total hip arthroplasty with minimum 12-month follow-up were evaluated. RESULTS: At mean follow-up of 18 months, at least 1 complication had occurred in 39 patients (20%) of 198 revisions. Single episode of dislocation, treated with close reduction, occurred in 16, whereas 2 patients required rerevision due to multiple dislocations. Infection requiring rerevision occurred in 3 patients. Adverse local tissue reaction recurrence requiring reoperation occurred in 6 patients. Implant survivorship for revision for any cause was 86% at 30 months. The reoperation rate of revised dual taper was 8% (16 out of 198 hips). The median serum levels of cobalt, chromium, and cobalt/chromium ratio decreased (P < .01) from 5.3 µg/L (range: 2.3-48.5 µg/L), 2.6 µg/L (range: 0.2-64 µg/L), and 4.7 (range: 2.1-35) prerevision to 1.4 µg/L (range: 0.2-8.8 µg/L), 0.7 µg/L (range: 0.1-3.9 µg/L), and 2.2 (range: 0.4-8.8) postrevision, respectively. CONCLUSION: This pilot study demonstrates that intraoperative tissue necrosis was associated with a high rate of early complications (20%) and revisions (8%), suggesting the importance of a systematic evaluation of these patients including metal ion levels and metal artifact reduction sequence magnetic resonance imaging in optimizing revision outcome, as early diagnosis will facilitate the initiation of appropriate treatment before significant adverse tissue necrosis.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Necrosis , Falla de Prótesis , Reoperación/métodos , Adulto , Anciano , Anciano de 80 o más Años , Cromo/sangre , Cobalto/sangre , Corrosión , Femenino , Fémur , Cuello Femoral/cirugía , Estudios de Seguimiento , Humanos , Periodo Intraoperatorio , Luxaciones Articulares , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Proyectos Piloto , Diseño de Prótesis , Infección de la Herida Quirúrgica , Resultado del Tratamiento
5.
Adv Orthop ; 2015: 719091, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26664755

RESUMEN

In effort to reduce the revision burden of total knee arthroplasty (TKA), industry emphasis has focused on replacing manual techniques-which are subject to variability-with technological implements. Unfortunately, technological innovation often continues before adequate time for critical evaluation has passed. Therefore, the purpose of this descriptive literature review was to collect a large sample of international data and report on the clinical and economic efficacy of three major types of technologically assisted TKA: navigation, patient-specific instrumentation, and sensorized trials.

6.
J Arthroplasty ; 23(3): 383-94, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18358377

RESUMEN

This study reports the results of 41 revision hips, implanted by a single surgeon using impaction grafting (mean follow-up, 4.7 years). All hips had Paprosky scores of III or IV. Harris hip scores improved from 43 to 82. There was 1 intraoperative and 2 postoperative fractures. A single stem was revised during the study. Radiographic review showed the 40 unrevised stems to be stable, and graft incorporation was seen in at least 1 zone in 100% of the femurs. There was no stem subsidence greater than 2.5 mm. The results of this study demonstrate that preoperative planning and a surgical technique, which emphasizes femoral support and vigorous impaction grafting, resulted in an acceptable incidence of complications.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Trasplante Óseo , Fémur/cirugía , Osteoporosis/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Trasplante Óseo/métodos , Femenino , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Fémur/diagnóstico por imagen , Estudios de Seguimiento , Curación de Fractura , Supervivencia de Injerto , Articulación de la Cadera/diagnóstico por imagen , Humanos , Complicaciones Intraoperatorias , Masculino , Persona de Mediana Edad , Osteoporosis/diagnóstico por imagen , Complicaciones Posoperatorias , Radiografía , Reoperación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA