Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Rev Assoc Med Bras (1992) ; 67(6): 878-881, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34709334

RESUMEN

OBJECTIVE: The aim of this study was to verify the association among obstructive sleep apnea, functional capacity, and metabolic control. METHODS: This was a cross-sectional study involving individuals of both sexes with clinical diagnosis of diabetes mellitus type 2 who were above 18 years of age. The assessment consisted of a volunteer identification form, a 2-minute step test, and the Stop-Bang questionnaire. In order to assess metabolic control, HbA1c and fasting glucose data were collected from medical records. RESULTS: A total of 100 individuals with diabetes mellitus type 2, of whom 61% were women, were included in this study. According to the Stop-Bang instrument, 26, 57, and 17% of patients had low, intermediate, and high risk of developing OSA, respectively. There was no association between the 2-minute step test and metabolic variables and diabetes mellitus type 2 chronicity with Stop-Bang. CONCLUSIONS: We concluded that there is no association among obstructive sleep apnea measured by means of Stop-Bang instrument, functional capacity measured by means of 2-minute step test, and metabolic variables in individuals with diabetes mellitus type 2.


Asunto(s)
Diabetes Mellitus Tipo 2 , Apnea Obstructiva del Sueño , Estudios Transversales , Diabetes Mellitus Tipo 2/complicaciones , Femenino , Humanos , Masculino , Polisomnografía , Estudios Prospectivos , Apnea Obstructiva del Sueño/epidemiología , Encuestas y Cuestionarios
2.
Rev. Assoc. Med. Bras. (1992, Impr.) ; Rev. Assoc. Med. Bras. (1992, Impr.);67(6): 878-881, June 2021. tab
Artículo en Inglés | LILACS | ID: biblio-1346909

RESUMEN

SUMMARY OBJECTIVE: The aim of this study was to verify the association among obstructive sleep apnea, functional capacity, and metabolic control. METHODS: This was a cross-sectional study involving individuals of both sexes with clinical diagnosis of diabetes mellitus type 2 who were above 18 years of age. The assessment consisted of a volunteer identification form, a 2-minute step test, and the Stop-Bang questionnaire. In order to assess metabolic control, HbA1c and fasting glucose data were collected from medical records. RESULTS: A total of 100 individuals with diabetes mellitus type 2, of whom 61% were women, were included in this study. According to the Stop-Bang instrument, 26, 57, and 17% of patients had low, intermediate, and high risk of developing OSA, respectively. There was no association between the 2-minute step test and metabolic variables and diabetes mellitus type 2 chronicity with Stop-Bang. CONCLUSIONS: We concluded that there is no association among obstructive sleep apnea measured by means of Stop-Bang instrument, functional capacity measured by means of 2-minute step test, and metabolic variables in individuals with diabetes mellitus type 2.


Asunto(s)
Humanos , Masculino , Femenino , Apnea Obstructiva del Sueño/epidemiología , Diabetes Mellitus Tipo 2/complicaciones , Estudios Transversales , Estudios Prospectivos , Encuestas y Cuestionarios , Polisomnografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA