1.
Opt Express ; 21(12): 14736-46, 2013 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-23787661

RESUMEN

In this work we present a LIDAR sensor devised for the acquisition of time resolved laser induced fluorescence spectra. The gating time for the acquisition of the fluorescence spectra can be sequentially delayed in order to achieve fluorescence data that are resolved both in the spectral and temporal domains. The sensor can provide sub-nanometric spectral resolution and nanosecond time resolution. The sensor has also imaging capabilities by means of a computer-controlled motorized steering mirror featuring a biaxial angular scanning with 200 µradiant angular resolution. The measurement can be repeated for each point of a geometric grid in order to collect a hyper-spectral time-resolved map of an extended target.


Asunto(s)
Monitoreo del Ambiente/instrumentación , Rayos Láser , Radar/instrumentación , Tecnología de Sensores Remotos/instrumentación , Espectrometría de Fluorescencia/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Mapeo Geográfico
2.
Photosynth Res ; 108(2-3): 225-39, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21866392

RESUMEN

A new computational procedure to resolve the contribution of Photosystem I (PSI) and Photosystem II (PSII) to the leaf chlorophyll fluorescence emission spectra at room temperature has been developed. It is based on the Principal Component Analysis (PCA) of the leaf fluorescence emission spectra measured during the OI photochemical phase of fluorescence induction kinetics. During this phase, we can assume that only two spectral components are present, one of which is constant (PSI) and the other variable in intensity (PSII). Application of the PCA method to the measured fluorescence emission spectra of Ficus benjamina L. evidences that the temporal variation in the spectra can be ascribed to a single spectral component (the first principal component extracted by PCA), which can be considered to be a good approximation of the PSII fluorescence emission spectrum. The PSI fluorescence emission spectrum was deduced by difference between measured spectra and the first principal component. A single-band spectrum for the PSI fluorescence emission, peaked at about 735 nm, and a 2-band spectrum with maxima at 685 and 740 nm for the PSII were obtained. A linear combination of only these two spectral shapes produced a good fit for any measured emission spectrum of the leaf under investigation and can be used to obtain the fluorescence emission contributions of photosystems under different conditions. With the use of our approach, the dynamics of energy distribution between the two photosystems, such as state transition, can be monitored in vivo, directly at physiological temperatures. Separation of the PSI and PSII emission components can improve the understanding of the fluorescence signal changes induced by environmental factors or stress conditions on plants.


Asunto(s)
Algoritmos , Clorofila/metabolismo , Ficus/metabolismo , Complejo de Proteína del Fotosistema I/metabolismo , Complejo de Proteína del Fotosistema II/metabolismo , Hojas de la Planta/metabolismo , Temperatura , Ficus/efectos de la radiación , Cinética , Análisis de los Mínimos Cuadrados , Luz , Hojas de la Planta/efectos de la radiación , Espectrometría de Fluorescencia
3.
Appl Opt ; 41(9): 1780-7, 2002 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-11921809

RESUMEN

Biodeteriogens are an important cause of the weathering of a monument, particularly those made of stone, and their detection at an early stage of development helps to protect the monument from deterioration. Frequent mapping of biodeteriogen accumulation is therefore highly necessary. The use of fluorescence lidar for this purpose was introduced in 1995 and has been developed in subsequent years. Three main aspects emerged during this research: the possibility of discriminating between different biodeteriogen strains, the minimum detectable quantity of biodeteriogens, and the control of the efficiency of biocide treatments. We describe the results of a laboratory experiment devoted to clarifying these three aspects of biodeteriogen monitoring by means of fluorescence lidar.