1.
Proc Natl Acad Sci U S A ; 118(47)2021 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-34782480

RESUMEN

There is rich clinical evidence that observing normally executed actions promotes the recovery of the corresponding action execution in patients with motor deficits. In this study, we assessed the ability of action observation to prevent the decay of healthy individuals' motor abilities following upper-limb immobilization. To this end, upper-limb kinematics was recorded in healthy participants while they performed three reach-to-grasp movements before immobilization and the same movements after 16 h of immobilization. The participants were subdivided into two groups; the experimental group observed, during the immobilization, the same reach-to-grasp movements they had performed before immobilization, whereas the control group observed natural scenarios. After bandage removal, motor impairment in performing reach-to-grasp movements was milder in the experimental group. These findings support the hypothesis that action observation, via the mirror mechanism, plays a protective role against the decline of motor performance induced by limb nonuse. From this perspective, action observation therapy is a promising tool for anticipating rehabilitation onset in clinical conditions involving limb nonuse, thus reducing the burden of further rehabilitation.


Asunto(s)
Fuerza de la Mano/fisiología , Inmovilización/fisiología , Movimiento/fisiología , Desempeño Psicomotor/fisiología , Adulto , Fenómenos Biomecánicos , Femenino , Humanos , Masculino , Observación , Rehabilitación , Extremidad Superior , Adulto Joven
2.
Surg Radiol Anat ; 46(2): 249-258, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38265490

RESUMEN

PURPOSE: The study aimed to obtain a comprehensive 3D visualization of knee specimens, including the cruciate ligaments and corresponding femoral and tibial bone insertions using a non-destructive micro-CT method. METHODS: Knee specimens were fixed in anatomical positions and chemically dehydrated before being scanned using micro-CT with a voxel size of 17.5 µm. RGBA (red, green, blue, alpha) transfer functions were applied to virtually colorize each structure. Following micro-CT scanning, the samples were rehydrated, decalcified, and trimmed based on micro-CT 3D reconstructions as references. Histological evaluations were performed on the trimmed samples. Histological and micro-CT images were registered to morphologically and densitometrically assess the 4-layer insertion of the ACL into the bone. RESULTS: The output of the micro-CT images of the knee in extension and flexion allowed a clear differentiation of the morphologies of both soft and hard tissues, such as the ACL, femoral and tibial bones, and cartilage, and the subsequent creation of 3D composite models useful for accurately tracing the entire morphology of the ligament, including its fiber and bundle components, the trajectory between the femur and tibia, and the size, extension, and morphology of its insertions into the bones. CONCLUSION: The implementation of the non-destructive micro-CT method allowed complete visualization of all the different components of the knee specimens. This allowed correlative imaging by micro-CT and histology, accurate planning of histological sections, and virtual anatomical and microstructural analysis. The micro-CT approach provided an unprecedented 3D level of detail, offering a viable means to study ACL anatomy.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior , Humanos , Ligamento Cruzado Anterior/diagnóstico por imagen , Ligamento Cruzado Anterior/anatomía & histología , Microtomografía por Rayos X , Imagenología Tridimensional/métodos , Articulación de la Rodilla/diagnóstico por imagen , Tibia/diagnóstico por imagen , Fémur/diagnóstico por imagen
3.
Aging Clin Exp Res ; 35(6): 1357-1361, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37071388

RESUMEN

Gait smoothness, perceived when a person walks continuously and uninterruptedly, is associated with an undisrupted gait pattern, good sensorimotor control, and a lower risk of falling. The spectral arc length (SPARC) is a quantitative metric proposed for the evaluation of movement smoothness from the signal obtained by wearable sensors. In this small exploratory case-control study, older persons with and without a history of injurious falls underwent a turn-test while wearing an accelerometer: gait smoothness was estimated by calculating SPARC during the straight and turning phases. Cases seemed to exhibit lower SPARC values during the turning phase, in comparison with control.


Asunto(s)
Marcha , Caminata , Humanos , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Movimiento
4.
Int J Sports Med ; 44(7): 463-472, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36807279

RESUMEN

This study aimed to review the impact of training on muscle power in patients with chronic obstructive pulmonary disease (COPD). Randomized controlled trials evaluating the effects of exercise-based interventions on limbs muscle power and rate of force development in COPD patients were investigated. Five international databases were searched until October 2022. Meta-analyses were performed calculating the mean difference or standardized mean difference. Risk of bias in studies was assessed using Cochrane Risk of Bias tool 2.0. A total of nine studies were included in the analysis. There were concerns about risk of bias in seven out of nine studies. Comparison of exercising and non-exercising groups showed a significant effect of exercise in improving muscle power (P=0.0004) and rate of force development (P<0.001), in five and three trials, respectively. Four studies comparing different trainings showed no significant results on muscle power (P=0.45). Eight to 16 weeks of exercise-based intervention versus no intervention might be beneficial to enhance upper and lower limbs muscle power and rate of force development in people with COPD. In contrast, muscle power did not improve when different training modalities were compared. Future studies performing power training in COPD patients are encouraged.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Humanos , Enfermedad Pulmonar Obstructiva Crónica/terapia , Ejercicio Físico , Músculos , Calidad de Vida , Ensayos Clínicos Controlados Aleatorios como Asunto
5.
Sensors (Basel) ; 23(6)2023 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-36991886

RESUMEN

Obesity has a critical impact on musculoskeletal systems, and excessive weight directly affects the ability of subjects to realize movements. It is important to monitor the activities of obese subjects, their functional limitations, and the overall risks related to specific motor tasks. From this perspective, this systematic review identified and summarized the main technologies specifically used to acquire and quantify movements in scientific studies involving obese subjects. The search for articles was carried out on electronic databases, i.e., PubMed, Scopus, and Web of Science. We included observational studies performed on adult obese subjects whenever reporting quantitative information concerning their movement. The articles must have been written in English, published after 2010, and concerned subjects who were primarily diagnosed with obesity, thus excluding confounding diseases. Marker-based optoelectronic stereophotogrammetric systems resulted to be the most adopted solution for movement analysis focused on obesity; indeed, wearable technologies based on magneto-inertial measurement units (MIMUs) were recently adopted for analyzing obese subjects. Further, these systems are usually integrated with force platforms, so as to have information about the ground reaction forces. However, few studies specifically reported the reliability and limitations of these approaches due to soft tissue artifacts and crosstalk, which turned out to be the most relevant problems to deal with in this context. In this perspective, in spite of their inherent limitations, medical imaging techniques-such as Magnetic Resonance Imaging (MRI) and biplane radiography-should be used to improve the accuracy of biomechanical evaluations in obese people, and to systematically validate less-invasive approaches.


Asunto(s)
Obesidad , Dispositivos Electrónicos Vestibles , Adulto , Humanos , Reproducibilidad de los Resultados , Movimiento , Imagen por Resonancia Magnética
6.
Sensors (Basel) ; 23(22)2023 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-38005650

RESUMEN

In recent years, wearable systems based on inertial sensors opened new perspectives for functional motor assessment with respect to the gold standard motion capture systems. The aim of this study was to validate an experimental set-up based on 17 body-worn inertial sensors (Awinda, Xsens, The Netherlands), addressing specific body segments with respect to the state-of-the art system (VICON, Oxford Metrics Ltd., Oxford, UK) to assess upper limb kinematics in obese, with respect to healthy subjects. Twenty-three obese and thirty healthy weight individuals were simultaneously acquainted with the two systems across a set of three tasks for upper limbs (i.e., frontal arm rise, lateral arm rise, and reaching). Root Mean Square error (RMSE) was computed to quantify the differences between the measurements provided by the systems in terms of range of motion (ROM), whilst their agreement was assessed via Pearson's correlation coefficient (PCC) and Bland-Altman (BA) plots. In addition, the signal waveforms were compared via one-dimensional statistical parametrical mapping (SPM) based on a paired t-test and a two-way ANOVA was applied on ROMs. The overall results partially confirmed the correlation and the agreement between the two systems, reporting only a moderate correlation for shoulder principal rotation angle in each task (r~0.40) and for elbow/flexion extension in obese subjects (r = 0.66), whilst no correlation was found for most non-principal rotation angles (r < 0.40). Across the performed tasks, an average RMSE of 34° and 26° was reported in obese and healthy controls, respectively. At the current state, the presence of bias limits the applicability of the inertial-based system in clinics; further research is intended in this context.


Asunto(s)
Hombro , Extremidad Superior , Humanos , Codo , Obesidad , Fenómenos Biomecánicos , Rango del Movimiento Articular , Rotación
7.
Knee Surg Sports Traumatol Arthrosc ; 30(11): 3616-3625, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33912979

RESUMEN

PURPOSE: Abnormal joint biomechanics and poor neuromuscular control are modifiable risk factors for Anterior Cruciate Ligament (ACL) injury. Although 3D motion capture is the gold standard for the biomechanical evaluation of high-speed multidirectional movements, 2D video analysis is a growing-interest alternative because of its higher cost-effectiveness and interpretability. The aim of the present study was to explore the possible association between a 2D evaluation of a 90° change of direction (COD) and the KAM measured with gold standard 3D motion analysis. METHODS: Thirty-four competitive football (soccer) players (age 22.8 ± 4.1, 18 male and 16 females) were enrolled. Each athlete performed a series of pre-planned 90° COD at the maximum speed possible in a laboratory equipped with artificial turf. 3D motion analysis was recorded using 10 stereophotogrammetric cameras, a force platform, and three high-speed cameras. The 2D evaluation was performed through a scoring system based on the video analysis of frontal and sagittal plane joint kinematics. Five scoring criteria were adopted: limb stability (LS), pelvis stability (PS), trunk stability (TS), shock absorption (SA), and movement strategy (MS). For each criterion, a sub-score of 0/2 (non-adequate), 1/2 (partially adequate), or 2/2 (adequate) was attributed to the movement, based on objective measurements. The intra-rater and inter-rater reliability were calculated for each criterion and the total score. The Knee Abduction Moment (KAM) was extracted from the 3D motion analysis and grouped according to the results of the 2D evaluation. RESULTS: Excellent intra-rater reliability (ICC > 0.88) and good-to-excellent inter-rater reliability (ICC 0.68-0.92) were found. Significantly higher KAM was found for athletes obtaining a 0/2 score compared to those obtaining a 2/2 score in all the sub-criteria and the total score (20-47% higher, p < 0.05). The total score and the LS score showed the best discriminative power between the three groups. CONCLUSION: The 2D video-analysis scoring system here described was a simple and effective tool to discriminate athletes with high and low KAM in the assessment of a 90° COD and could be a potential method to identify athletes at high risk of non-contact ACL injury. LEVEL OF EVIDENCE: IV.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Fútbol , Femenino , Humanos , Masculino , Lesiones del Ligamento Cruzado Anterior/diagnóstico , Lesiones del Ligamento Cruzado Anterior/cirugía , Fenómenos Biomecánicos , Articulación de la Rodilla , Reproducibilidad de los Resultados , Fútbol/lesiones
8.
Sensors (Basel) ; 22(15)2022 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-35957372

RESUMEN

Every year in Europe more than 500 thousand injuries that involve the anterior cruciate ligament (ACL) are diagnosed. The ACL is one of the main restraints within the human knee, focused on stabilizing the joint and controlling the relative movement between the tibia and femur under mechanical stress (i.e., laxity). Ligament laxity measurement is clinically valuable for diagnosing ACL injury and comparing possible outcomes of surgical procedures. In general, knee laxity assessment is manually performed and provides information to clinicians which is mainly subjective. Only recently quantitative assessment of knee laxity through instrumental approaches has been introduced and become a fundamental asset in clinical practice. However, the current solutions provide only partial information about either static or dynamic laxity. To support a multiparametric approach using a single device, an innovative smart knee brace for knee laxity evaluation was developed. Equipped with stretchable strain sensors and inertial measurement units (IMUs), the wearable system was designed to provide quantitative information concerning the drawer, Lachman, and pivot shift tests. We specifically characterized IMUs by using a reference sensor. Applying the Bland-Altman method, the limit of agreement was found to be less than 0.06 m/s2 for the accelerometer, 0.06 rad/s for the gyroscope and 0.08 µT for the magnetometer. By using an appropriate characterizing setup, the average gauge factor of the three strain sensors was 2.169. Finally, we realized a pilot study to compare the outcomes with a marker-based optoelectronic stereophotogrammetric system to verify the validity of the designed system. The preliminary findings for the capability of the system to discriminate possible ACL lesions are encouraging; in fact, the smart brace could be an effective support for an objective and quantitative diagnosis of ACL tear by supporting the simultaneous assessment of both rotational and translational laxity. To obtain reliable information about the real effectiveness of the system, further clinical validation is necessary.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Inestabilidad de la Articulación , Lesiones del Ligamento Cruzado Anterior/diagnóstico , Lesiones del Ligamento Cruzado Anterior/cirugía , Fenómenos Biomecánicos , Humanos , Inestabilidad de la Articulación/diagnóstico , Articulación de la Rodilla/cirugía , Proyectos Piloto , Rango del Movimiento Articular
9.
Sensors (Basel) ; 22(17)2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36081078

RESUMEN

Several systems, sensors, and devices are now available for the instrumental evaluation of physical function in persons with Chronic Obstructive Pulmonary Disease (COPD). We aimed to systematically review the literature about such technologies. The literature search was conducted in all major scientific databases, including articles published between January 2001 and April 2022. Studies reporting measures derived from the instrumental assessment of physical function in individuals with COPD were included and were divided into application and validation studies. The quality of validation studies was assessed with the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) risk of bias tool. From 8752 articles retrieved, 21 application and 4 validation studies were included in the systematic review. Most application studies employed accelerometers, gait analysis systems, instrumented mattresses, or force plates to evaluate walking. Surface electro-myography or near-infrared spectroscopy were employed in four studies. Validation studies were heterogeneous and presented a risk of bias ranging from inadequate to doubtful. A variety of data regarding physical function can be retrieved from technologies used in COPD studies. However, a general lack of standardization and limitations in study design and sample size hinder the implementation of the instrumental evaluation of function in clinical practice.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Humanos , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Caminata
10.
Knee Surg Sports Traumatol Arthrosc ; 29(2): 507-518, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32266415

RESUMEN

PURPOSE: Comparing the MRI features of the grafts between a group of patients treated with an over-the-top anterior cruciate ligament reconstruction technique that preserves the hamstring attachment and a control group with a classical reconstruction technique. METHODS: Patients were assigned to a standard reconstruction technique or an Over-the-top plus lateral plasty technique. All patients underwent preoperative, 4-months and 18-months MRI; together with a clinical evaluation with KOOS and KT1000 laxity assessment. MRI study involved different parameters: the "Graft" was evaluated with the continuity, Howell Grading system, presence of liquid and signal noise quotient. The "Tibial Tunnel" was evaluated with the signal noise quotient, presence of edema or liquid and tunnel widening. All points assigned to each parameter formed a composite score ranging from 0-10. Tunnel and graft positioning were evaluated. RESULTS: At 18-month 20 MRIs (10 each group) were available, demographics were not significantly different between groups. The non-detached group showed significantly less liquid within the graft at 4-months (p = 0.008) and 18-months (p = 0.028), the tunnel was significantly smaller (p < 0.05) and less enlarged at both follow-ups (p < 0.05), signal noise quotient of the intra-tunnel graft was lower at 18-months (p < 0.05). The total score of the non-detached group saw a significant improvement at 4-months (p = 0.006) that remained stable at 18-months (n.s.). CONCLUSIONS: Hamstring grafts, which tibial insertions were preserved, showed better MRI features at 4-and 18-months follow-up, especially in terms of liquid effusion, tunnel enlargement and signal noise quotient. LEVEL OF EVIDENCE: IV.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Tendones Isquiotibiales/trasplante , Imagen por Resonancia Magnética/métodos , Tibia/cirugía , Adolescente , Adulto , Ligamento Cruzado Anterior/diagnóstico por imagen , Ligamento Cruzado Anterior/cirugía , Femenino , Músculos Isquiosurales/cirugía , Tendones Isquiotibiales/diagnóstico por imagen , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/cirugía , Prótesis Articulares , Masculino , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto , Tibia/diagnóstico por imagen , Adulto Joven