Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Glaucoma ; 26(9): 792-797, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28857943

RESUMEN

PURPOSE: To compare the visibility of deep optic nerve head (ONH) structures and the visible area of the anterior surface of the lamina cribrosa (ASLC) with spectral-domain optical coherence tomography (SD-OCT) and swept-source OCT (SS-OCT). MATERIALS AND METHODS: In total, 33 glaucoma patients were imaged with SD-OCT (Spectralis, 24 radial B-scans centered on the ONH) and SS-OCT (Atlantis, 12 radial and a horizontal and vertical raster scan pattern containing 5 lines each, centered on the ONH). One of the SS-OCT horizontal and vertical scans that was best matching with the horizontal and vertical scan lines with those of SD-OCT was selected. All B-scans were then exported and deidentified. An independent observer determined whether the posterior choroid, border tissue, anterior scleral canal opening, and LC insertion into the sclera were detectable in the matched scan lines. Bruch membrane opening (BMO) and ASLC were segmented manually in radial scans. The segmented points were combined into a single plane and a linear interpolation was used to define BMO and ASLC areas. RESULTS: The posterior choroid, border tissue, and anterior scleral canal opening were detectable in most patients (94% to 100%, 88% to 100%, and 76% to 100%, respectively) and were not different between SD-OCT and SS-OCT. The LC insertion detection rate was nonstatistically higher for SS-OCT compared with SD-OCT (58% to 85% vs. 42% to 73%; P>0.10). The mean (SD) ASLC visible area (percentage of the respective BMO area) was 124 (30%) with SD-OCT and 135 (32%) with SS-OCT (P<0.01). CONCLUSION: SD-OCT and SS-OCT had comparable detection rates of deep ONH structures; however, a larger area of ASLC was visible with SS-OCT.


Asunto(s)
Glaucoma de Ángulo Abierto/diagnóstico por imagen , Disco Óptico/diagnóstico por imagen , Enfermedades del Nervio Óptico/diagnóstico por imagen , Tomografía de Coherencia Óptica , Anciano , Segmento Anterior del Ojo/diagnóstico por imagen , Lámina Basal de la Coroides/diagnóstico por imagen , Femenino , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Tomografía de Coherencia Óptica/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA