Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Más filtros

Intervalo de año de publicación
1.
Circulation ; 146(17): 1268-1280, 2022 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-35862109

RESUMEN

BACKGROUND: Clinical and anatomical characteristics are often considered key factors in deciding between percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) in patients with complex coronary artery disease (CAD) such as left-main CAD or 3-vessel disease. However, little is known about the interaction between self-reported preprocedural physical/mental health and clinical outcomes after revascularization. METHODS: This subgroup analysis of the SYNTAXES trial (SYNTAX Extended Survival), which is the extended follow-up of the randomized SYNTAX trial (Synergy Between PCI With Taxus and Cardiac Surgery) comparing PCI with CABG in patients with left-main CAD or 3-vessel disease, stratified patients by terciles of Physical (PCS) or Mental Component Summary (MCS) scores derived from the preprocedural 36-Item Short Form Health Survey, with higher PCS and MCS scores representing better physical and mental health, respectively. The primary end point was all-cause death at 10 years. RESULTS: A total of 1656 patients with preprocedural 36-Item Short Form Health Survey data were included in the present study. Both higher PCS and MCS were independently associated with lower 10-year mortality (10-point increase in PCS adjusted hazard ratio, 0.84 [95% CI, 0.73-0.97]; P=0.021; in MCS adjusted hazard ratio, 0.85 [95% CI, 0.76-0.95]; P=0.005). A significant survival benefit with CABG over PCI was observed in the highest PCS (>45.5) and MCS (>52.3) terciles with significant treatment-by-subgroup interactions (PCS Pinteraction=0.033, MCS Pinteraction=0.015). In patients with both high PCS (>45.5) and MCS (>52.3), 10-year mortality was significantly higher with PCI compared with CABG (30.5% versus 12.2%; hazard ratio, 2.87 [95% CI, 1.55-5.30]; P=0.001), whereas among those with low PCS (≤45.5) or low MCS (≤52.3), there were no significant differences in 10-year mortality between PCI and CABG, resulting in a significant treatment-by-subgroup interaction (Pinteraction=0.002). CONCLUSIONS: Among patients with left-main CAD or 3-vessel disease, patient-reported preprocedural physical and mental health status was strongly associated with long-term mortality and modified the relative treatment effects of PCI versus CABG. Patients with the best physical and mental health had better 10-year survival with CABG compared with PCI. Assessment of self-reported physical and mental health is important when selecting the optimal revascularization strategy. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; SYNTAXES Unique identifier: NCT03417050. URL: https://www. CLINICALTRIALS: gov; SYNTAX Unique identifier: NCT00114972.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/cirugía , Salud Mental , Medición de Resultados Informados por el Paciente , Factores de Riesgo , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto
2.
Cardiovasc Diabetol ; 21(1): 246, 2022 11 16.
Artículo en Inglés | MEDLINE | ID: mdl-36384656

RESUMEN

BACKGROUND: Diabetes Mellitus (DM) affects a third of patients with symptomatic severe aortic valve stenosis undergoing transcatheter aortic valve implantation (TAVI). DM is a well-known risk factor for cardiac surgery, but its prognostic impact in TAVI patients remains controversial. This study aimed to evaluate outcomes in diabetic patients undergoing TAVI. METHODS: This multicentre registry includes data of > 12,000 patients undergoing transfemoral TAVI. We assessed baseline patient characteristics and clinical outcomes in patients with DM and without DM. Clinical outcomes were defined by the second valve academic research consortium. Propensity score matching was applied to minimize potential confounding. RESULTS: Of the 11,440 patients included, 31% (n = 3550) had DM and 69% (n = 7890) did not have DM. Diabetic patients were younger but had an overall worse cardiovascular risk profile than non-diabetic patients. All-cause mortality rates were comparable at 30 days (4.5% vs. 4.9%, RR 0.9, 95%CI 0.8-1.1, p = 0.43) and at one year (17.5% vs. 17.4%, RR 1.0, 95%CI 0.9-1.1, p = 0.86) in the unmatched population. Propensity score matching obtained 3281 patient-pairs. Also in the matched population, mortality rates were comparable at 30 days (4.7% vs. 4.3%, RR 1.1, 95%CI 0.9-1.4, p = 0.38) and one year (17.3% vs. 16.2%, RR 1.1, 95%CI 0.9-1.2, p = 0.37). Other clinical outcomes including stroke, major bleeding, myocardial infarction and permanent pacemaker implantation, were comparable between patients with DM and without DM. Insulin treated diabetics (n = 314) showed a trend to higher mortality compared with non-insulin treated diabetics (n = 701, Hazard Ratio 1.5, 95%CI 0.9-2.3, p = 0.08). EuroSCORE II was the most accurate risk score and underestimated 30-day mortality with an observed-expected ratio of 1.15 in DM patients, STS-PROM overestimated actual mortality with a ratio of 0.77 and Logistic EuroSCORE with 0.35. CONCLUSION: DM was not associated with mortality during the first year after TAVI. DM patients undergoing TAVI had low rates of mortality and other adverse clinical outcomes, comparable to non-DM TAVI patients. Our results underscore the safety of TAVI treatment in DM patients. TRIAL REGISTRATION: The study is registered at clinicaltrials.gov (NCT03588247).


Asunto(s)
Estenosis de la Válvula Aórtica , Diabetes Mellitus , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiología , Diabetes Mellitus/etiología , Puntaje de Propensión , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Multicéntricos como Asunto , Sistema de Registros
3.
BMC Cancer ; 22(1): 396, 2022 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-35413811

RESUMEN

Cancer-therapy related cardiotoxicity (CTRCT) is a significant and frequent complication of monoclonal antibody directed therapy, especially Trastuzumab, for human epidermal growth factor receptor 2 (HER2) overexpressing breast cancers. Reliable, clinically available molecular predictive markers of CTRCT have not yet been developed. Identifying specific genetic variants and their molecular markers, which make the host susceptible to this complication is key to personalised risk stratification. A systematic review was conducted until April 2021, using the Medline, Embase databases and Google Scholar, to identify studies genetic and RNA-related markers associated with CTRCT in HER2 positive breast cancer patients. So far, researchers have mainly focused on HER2 related polymorphisms, revealing codons 655 and 1170 variants as the most likely SNPs associated with cardiotoxicity, despite some contradictory results. More recently, new potential genetic markers unrelated to the HER2 gene, and linked to known cardiomyopathy genes or to genes regulating cardiomyocytes apoptosis and metabolism, have been detected. Moreover, microRNAs are gaining increasing recognition as additional potential molecular markers in the cardio-oncology field, supported by encouraging preliminary data about their relationship with cardiotoxicity in breast cancers. In this review, we sought to synthesize evidence for genetic variants and RNA-related molecular markers associated with cardiotoxicity in HER2-positive breast cancer.


Asunto(s)
Neoplasias de la Mama , Cardiotoxicidad , Neoplasias de la Mama/complicaciones , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/genética , Cardiotoxicidad/genética , Femenino , Humanos , ARN , Receptor ErbB-2/genética , Receptor ErbB-2/metabolismo , Trastuzumab/efectos adversos
4.
Catheter Cardiovasc Interv ; 99(6): 1925-1934, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35312158

RESUMEN

The volume of contrast to creatinine clearance ratio (CV/CrCl) is a useful indicator of the risk of acute kidney injury (AKI) in patients undergoing percutaneous interventional procedures. Association between CV/CrCl and adverse outcome after transcatheter aortic valve implantation (TAVI) was suggested but it is not well established. A large retrospective multicenter cohort of 1381 patients treated with TAVI was analyzed to assess the association between CV/CrCl and the risk of AKI and mortality at 90 days and 1 year after TAVI. Patients receiving renal replacement therapy at the time of TAVI were excluded. CV/CrCl ≥ 2.2 was associated with the risk of AKI and 90 days mortality after TAVI after adjustment for age, sex, diabetes, baseline left ventricular function, baseline chronic kidney disease (CKD), previous myocardial infarction and peripheral vascular disease (hazard ratio [HR]: 1.16, 95% confidence interval [CI]: 1.09-1.22, p < 0.0001). Importantly, CV/CrCl was associated with the adverse outcome independently from the presence of baseline CKD (p for interaction = 0.22). CV/CrCl was independently associated with the individual components of the composite primary outcome including AKI (odds ratio: 1.18, 95% CI: 1.08-1.28, p < 0.0001) and 90 days mortality (HR: 1.90, 95% CI: 1.01-3.60, p = 0.047) after TAVI. AKI (HR: 1.94, 95% CI: 1.21-3.11, p = 0.006) but not CV/CrCl was associated with the risk of 1-year mortality after TAVI. CV/CrCl is associated with excess renal damage and early mortality after TAVI. Procedural strategies to minimize the CV/CrCl during TAVI may improve early clinical outcomes in patients undergoing TAVI.


Asunto(s)
Lesión Renal Aguda , Estenosis de la Válvula Aórtica , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Creatinina , Femenino , Tasa de Filtración Glomerular , Humanos , Masculino , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
5.
Catheter Cardiovasc Interv ; 98(3): E466-E470, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-32979026

RESUMEN

Hybrid multidisciplinary interventions are attractive care options for heart valve and vascular diseases in high-risk patients. We describe the feasibility of staged hybrid aortic arch repair to treat a type Ia endoleak and transcatheter aortic valve replacement to treat an aortic valve stenosis, achieving an escape strategy to treat an unexpected type-A aortic dissection.


Asunto(s)
Aneurisma de la Aorta Torácica , Estenosis de la Válvula Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Disección , Procedimientos Endovasculares/efectos adversos , Humanos , Resultado del Tratamiento
6.
Eur Heart J ; 40(5): 456-465, 2019 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-30590565

RESUMEN

Aims: The aim of this study was to compare clinical outcomes of patients undergoing transfemoral transcatheter aortic valve implantation (TAVI) with balloon-expandable (BE) valves vs. self-expandable (SE) valves. Transcatheter aortic valve implantation is a minimally invasive and lifesaving treatment in patients with aortic valve stenosis. Even though BE-valves and SE-valves are both commonly used on a large scale, adequately sized trials comparing clinical outcomes in patients with severe aortic valve stenosis treated with BE-valves compared with SE-valves are lacking. Methods and results: In this CENTER-collaboration, data from 10 registries or clinical trials, selected through a systematic search, were pooled and analysed. Propensity score methodology was used to reduce treatment selection bias and potential confounding. The primary endpoints were mortality and stroke at 30 days follow-up in patients treated with BE-valves compared with SE-valves. Secondary endpoints included clinical outcomes, e.g. bleeding during hospital admission. All outcomes were split for early-generation BE-valves compared with early-generation SE-valves and new-generation BE-valves with new-generation SE-valves. The overall patient population (N = 12 381) included 6239 patients undergoing TAVI with BE-valves and 6142 patients with SE-valves. The propensity matched population had a mean age of 81 ± 7 years and a median STS-PROM score or 6.5% [interquartile range (IQR) 4.0-13.0%]. At 30-day follow-up, the mortality rate was not statistically different in patients undergoing TAVI with BE-valves compared with SE-valves [BE: 5.3% vs. SE: 6.2%, relative risk (RR) 0.9; 95% confidence interval (CI) 0.7-1.0, P = 0.10]. Stroke occurred less frequently in patients treated with BE-valves (BE: 1.9% vs. SE: 2.6%, RR 0.7; 95% CI 0.5-1.0, P = 0.03). Also, patients treated with BE-valves had a three-fold lower risk of requiring pacemaker implantation (BE: 7.8% vs. SE: 20.3%, RR 0.4; 95% CI 0.3-0.4, P < 0.001). In contrast, patients treated with new-generation BE-valves more frequently experienced major and life-threatening bleedings compared with new-generation SE-valves (BE: 4.8% vs. SE: 2.1%, RR 2.3; 95% CI 1.6-3.3, P < 0.001). Conclusion: In this study, which is the largest study to compare valve types in TAVI, we demonstrated that the incidence of stroke and pacemaker implantation was lower in patients undergoing transfemoral TAVI with BE-valves compared with SE-valves. In contrast, patients treated with new-generation BE-valves more often suffered from major or life-threatening bleedings than patients with new-generation SE-valves. Mortality at 30-days was not statistically different in patients treated with BE-valves compared with SE-valves. This study was a propensity-matched analysis generated from observational data, accordingly current outcomes will have to be confirmed in a large scale randomized controlled trial.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Marcapaso Artificial/estadística & datos numéricos , Diseño de Prótesis , Accidente Cerebrovascular/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Conversión a Cirugía Abierta/estadística & datos numéricos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Estudios Observacionales como Asunto , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/mortalidad , Puntaje de Propensión , Sistema de Registros , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad
7.
J Interv Cardiol ; 30(4): 318-324, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28580767

RESUMEN

OBJECTIVES: In-stent restenosis (ISR) and diffuse small vessel disease still represent challenging subsets for percutaneous coronary interventions, also in the new-generation DES era. We aim at reporting on the long-term clinical outcome of drug-coated balloons (DCB) in all-comers population. METHODS: Consecutive patients treated with DCB between January 2011 and December 2014 were retrospectively studied in three centers of northern Italy. The measured end-points were cardiac death, myocardial infarction (MI), target lesion revascularization (TLR), and major adverse cardiac events (MACE) defined as combination of cardiac death, MI, and TLR. RESULTS: We included 143 patients. Of the 167 lesions treated, 41 (24.5%) were de novo lesions in small coronary vessels (<2.5 mm) and 126 (75.4%) were ISR. Among ISR lesions, 78.5% were DES-ISR, 32.5% were focal, 15.8% multifocal, 30.1% diffuse, 18.2% proliferative, and 3.1% were total occlusions. Procedural success was achieved in 94.6% of cases. Overall survival free from MACEs was 91.6% at 12 months, and 75.3% at 48 months, with a total of 3 cardiac deaths, 8 MI, and 27 TLR. No thrombotic event occurred in the treated segments. There were no differences in MACESs between the ISR and de novo lesions groups. At multivariate analysis, acute coronary syndromes, previous MI, previous surgical revascularization, peripheral arterial disease and diabetes were independent predictors of MACEs at long-term follow-up. CONCLUSIONS: DCB proved a valid revascularization strategy in an all-comers population of patients with ISR and de novo lesions in small vessels, with an acceptable rate of cardiac events up to 48 months follow-up.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Enfermedad de la Arteria Coronaria/terapia , Infarto del Miocardio/epidemiología , Complicaciones Posoperatorias/epidemiología , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Análisis Multivariante , Paclitaxel/administración & dosificación , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento
10.
Heart ; 110(8): 603-612, 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38040448

RESUMEN

OBJECTIVES: This study aimed to evaluate the prognostic value of coronary microvascular dysfunction (CMD) at long term after transcatheter aortic valve implantation (TAVI) and to explore its relationship with extravalvular cardiac damage (EVCD). Moreover, we sought to test the correlation between angiography-derived index of microcirculatory resistance (IMRangio) and invasive IMR in patients with aortic stenosis (AS). METHODS: This was a retrospective analysis of the Verona Valvular Heart Disease Registry (Italy) including 250 patients (83 (80-86) years, 53% female) with severe AS who underwent TAVI between 2019 and 2021. IMRangio was calculated offline using a computational flow model applied to coronary angiography obtained during the TAVI workup. CMD was defined as IMRangio ≥30 units.The primary endpoint was the composite of cardiovascular death and rehospitalisation for heart failure (HF). Advanced EVCD was defined as pulmonary circulation impairment, severe tricuspid regurgitation or right ventricular dysfunction.The correlation between IMR and IMRangio was prospectively assessed in 31 patients undergoing TAVI. RESULTS: The primary endpoint occurred in 28 (11.2%) patients at a median follow-up of 22 (IQR 12-30) months. Patients with CMD met the primary endpoint more frequently than those without CMD (22.9% vs 2.8%, p<0.0001). Patients with CMD were more frequently characterised by advanced EVCD (33 (31.4%) vs 27 (18.6%), p=0.024). CMD was an independent predictor of adverse outcomes (adjusted HR 6.672 (2.251 to 19.778), p=0.001) and provided incremental prognostic value compared with conventional clinical and imaging variables. IMRangio demonstrated fair correlation with IMR. CONCLUSIONS: CMD is an independent predictor of cardiovascular mortality and HF after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Isquemia Miocárdica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Microcirculación , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía
11.
G Ital Cardiol (Rome) ; 25(6): 23-37, 2024 Jun.
Artículo en Italiano | MEDLINE | ID: mdl-38912744

RESUMEN

STENT PANORAMA is a project carried out by the Young Interventional Cardiologists of Triveneto coordinated by the Italian Society of Interventional Cardiology (GISE) Veneto delegation. The project includes two parts: the first, here reported, is aimed at describing in a standardized and easily usable way the main technological characteristics of the latest generation of the drug eluting stents (DES) that are most widely used in the Italian cath-labs. The second, to follow, will aim to summarize the main scientific evidence regarding the performance of individual devices with particular reference to subgroups of clinical interest. The ambitious goal of the STENT PANORAMA working group is to provide the interventional cardiologist with a thorough, practical, and functional knowledge of the DES currently available in the modern therapeutic armamentarium to promote a therapeutic strategy tailored to the patient.


Asunto(s)
Stents Liberadores de Fármacos , Humanos , Italia , Intervención Coronaria Percutánea/métodos , Diseño de Prótesis , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/cirugía
12.
Eur Heart J Qual Care Clin Outcomes ; 10(1): 25-35, 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-37286294

RESUMEN

AIMS: As a consequence of untimely or missed revascularization of ST-elevation myocardial infarction (STEMI) patients during the COVID-19 pandemic, many patients died at home or survived with serious sequelae, resulting in potential long-term worse prognosis and related health-economic implications.This analysis sought to predict long-term health outcomes [survival and quality-adjusted life-years (QALYs)] and cost of reduced treatment of STEMIs occurring during the first COVID-19 lockdown. METHODS AND RESULTS: Using a Markov decision-analytic model, we incorporated probability of hospitalization, timeliness of PCI, and projected long-term survival and cost (including societal costs) of mortality and morbidity, for STEMI occurring during the first UK and Spanish lockdowns, comparing them with expected pre-lockdown outcomes for an equivalent patient group.STEMI patients during the first UK lockdown were predicted to lose an average of 1.55 life-years and 1.17 QALYs compared with patients presenting with a STEMI pre-pandemic. Based on an annual STEMI incidence of 49 332 cases, the total additional lifetime costs calculated at the population level were £36.6 million (€41.3 million), mainly driven by costs of work absenteeism. Similarly in Spain, STEMI patients during the lockdown were expected to survive 2.03 years less than pre-pandemic patients, with a corresponding reduction in projected QALYs (-1.63). At the population level, reduced PCI access would lead to additional costs of €88.6 million. CONCLUSION: The effect of a 1-month lockdown on STEMI treatment led to a reduction in survival and QALYs compared to the pre-pandemic era. Moreover, in working-age patients, untimely revascularization led to adverse prognosis, affecting societal productivity and therefore considerably increasing societal costs.


Asunto(s)
COVID-19 , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , COVID-19/epidemiología , Infarto del Miocardio con Elevación del ST/epidemiología , Infarto del Miocardio con Elevación del ST/cirugía , Pandemias , Estrés Financiero , Control de Enfermedades Transmisibles
13.
EuroIntervention ; 20(8): e504-e510, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38629420

RESUMEN

The treatment of coronary artery disease (CAD) in patients with severe aortic valve stenosis (AVS) eligible for transcatheter aortic valve implantation (TAVI) is not supported by clinical evidence, and the role of physiology over anatomy as well as the timing of coronary intervention are not defined. FAITAVI (ClinicalTrials.gov: NCT03360591) is a nationwide prospective, open-label, multicentre, randomised controlled study comparing the angiography-guided versus the physiology-guided coronary revascularisation strategy in patients with combined significant CAD and severe AVS undergoing TAVI. Significant CAD will be defined as coronary stenosis ≥50%, as assessed by visual estimation in vessels ≥2.5 mm. Physiology will be tested by fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR). The study will be conducted at 15 sites in Italy. In the angiography arm, percutaneous coronary intervention (PCI) will be performed either before TAVI, during the TAVI procedure - before or after the valve implantation - or within 1 month±5 days of the valve implantation, left to the operator's decision. In the physiology arm, FFR and iFR will be performed before TAVI, and PCI will be indicated for FFR ≤0.80, otherwise the intervention will be deferred. In case of borderline values (0.81-0.85), FFR and iFR will be repeated after TAVI, with PCI performed when needed. With a sample size of 320 patients, the study is powered to evaluate the primary endpoint (a composite of death, myocardial infarction, stroke, major bleeding, or ischaemia-driven target vessel revascularisation). TAVI indication, strategy and medical treatment will be the same in both groups. After discharge, patients will be contacted at 1, 6, 12 and 24 months after the procedure to assess their general clinical status, and at 12 months for the occurrence of events included in the primary and secondary endpoints. FAITAVI is the first randomised clinical trial to investigate "optimal" percutaneous coronary intervention associated with TAVI in patients with severe AVS and CAD.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Estudios Multicéntricos como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto
14.
EuroIntervention ; 20(1): 95-103, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37982161

RESUMEN

BACKGROUND: Midterm comparative analyses of the latest iterations of the most used Evolut and SAPIEN platforms for transcatheter aortic valve implantation (TAVI) are lacking. AIMS: We aimed to compare 1-year clinical outcomes of TAVI patients receiving Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices in current real-world practice. METHODS: Among patients enrolled in the OPERA-TAVI registry, patients with complete 1-year follow-up were considered for the purpose of this analysis. One-to-one propensity score matching was used to compare TAVI patients receiving PRO or ULTRA devices. The primary endpoint was a composite of 1-year all-cause death, disabling stroke and rehospitalisation for heart failure. Five prespecified subgroups of patients were considered according to leaflet and left ventricular outflow tract calcifications, annulus dimensions and angulation, and leaflet morphology. RESULTS: Among a total of 1,897 patients, 587 matched pairs of patients with similar clinical and anatomical characteristics were compared. The primary composite endpoint did not differ between patients receiving PRO or ULTRA devices (Kaplan-Meier [KM] estimates 14.0% vs 11.9%; log-rank p=0.27). Patients receiving PRO devices had higher rates of 1-year disabling stroke (KM estimates 2.6% vs 0.4%; log-rank p=0.001), predominantly occurring within 30 days after TAVI (1.4% vs 0.0%; p=0.004). Outcomes were consistent across all the prespecified subsets of anatomical scenarios (all pinteraction>0.10). CONCLUSIONS: One-year clinical outcomes of patients undergoing transfemoral TAVI and receiving PRO or ULTRA devices in the current clinical practice were similar, but PRO patients had higher rates of disabling stroke. Outcomes did not differ across the different anatomical subsets of the aortic root.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Sistema de Registros , Accidente Cerebrovascular/etiología , Diseño de Prótesis
15.
Am J Cardiol ; 219: 60-70, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38401656

RESUMEN

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Factores Sexuales , Anciano de 80 o más Años , Anciano , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología , Válvula Aórtica/cirugía
16.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38479968

RESUMEN

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Sistema de Registros , Accidente Cerebrovascular/etiología
17.
Clin Res Cardiol ; 2023 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-38112747

RESUMEN

BACKGROUND: Independent testing of home blood pressure (BP) measurement (HBPM) devices is often lacking, particularly among older and multi-morbid patients. METHODS: We studied the Bpro G2 (using tonometry), Omron HeartGuide (using occlusive oscillometric technology), and Heartisans (using photoplethysmography) wrist watch HBPM devices against a gold standard brachial sphygmomanometer. To test device performance, we used the ISO81060-2 protocol (though this protocol cannot formally validate cuffless devices). We also used linear mixed models to compare adjusted longitudinal BP measurements between devices. Finally, as a surrogate for usability, we recorded instances of device failure where no BP measurement was returned. RESULTS: We enrolled 128 participants (median [Q1-Q3] age 53 [40-65] years, 51% male, 46% on antihypertensive drugs), of whom 100 were suitable for the primary analysis. All three devices had mean BP values within 5 mmHg of sphygmomanometry. However, due to insufficient reliability (e.g., wider than accepted standard deviations of mean BP), none of the three devices passed all criteria required by the ISO81060-2 protocol. In adjusted longitudinal analyses, the Omron device also systematically underestimated systolic and diastolic BP (- 8.46 mmHg; 95% CI 6.07, 10.86; p < 0.001; and - 2.53 mmHg; 95% CI - 4.03, - 1.03; p = 0.001; respectively). Nevertheless, compared to the Omron device, BPro and Heartisans devices had increased odds of failure (BPro: odds ratio [OR] 5.24; p < 0.0001; Heartisans: OR 5.61; p < 0.001). CONCLUSIONS: While we could not formally validate the cuffless devices, our results show that wearable technologies will require improvements to offer reliable BP assessment. This study also highlights the need for validation protocols specifically designed for cuffless BP measurement technologies.

18.
Clin Res Cardiol ; 112(9): 1331-1342, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37338598

RESUMEN

OBJECTIVE: The risk of vessel-oriented cardiac adverse events (VOCE) in patients with diabetes mellitus (DM) undergoing intracoronary physiology-guided coronary revascularization is poorly defined. The purpose of this work is to evaluate the risk of VOCE in patients with and without DM in whom percutaneous coronary intervention (PCI) was performed or deferred based on pressure-wire functional assessment. METHODS: This is a retrospective analysis of a multicenter registry of patients evaluated with fractional flow reserve (FFR) and/or non-hyperaemic pressure ratio (NHPR). Primary endpoint was a composite of VOCE including cardiac death, vessel-related myocardial infarction (MI), and ischemia-driven target vessel revascularization (TVR). RESULTS: A large cohort of 2828 patients with 3353 coronary lesions was analysed to assess the risk of VOCE at long-term follow-up (23 [14-36] months). Non-insulin-dependent-DM (NIDDM) was not associated with the primary endpoint in the overall cohort (adjusted Hazard Ratio [aHR] 1.18, 95% CI 0.87-1.59, P = 0.276) or in patients with coronary lesions treated with PCI (aHR = 1.30, 95% CI 0.78-2.16, P = 0.314). Conversely, insulin-dependent diabetes mellitus (IDDM) demonstrated an increased risk of VOCE in the overall cohort (aHR 1.76, 95% CI 1.07-2.91, P = 0.027), but not in coronary lesions undergoing PCI (aHR 1.26, 95% CI 0.50-3.16, P = 0.621). Importantly, in coronary lesions deferred after functional assessment IDDM (aHR 2.77, 95% CI 1.11-6.93, P = 0.029) but not NIDDM (aHR = 0.94, 95% CI 0.61-1.44, P = 0.776) was significantly associated with the risk of VOCE. IDDM caused a significant effect modification of FFR-based risk stratification (P for interaction < 0.001). CONCLUSION: Overall, DM was not associated with an increased risk of VOCE in patients undergoing physiology-guided coronary revascularization. However, IDDM represents a phenotype at high risk of VOCE.


Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Reserva del Flujo Fraccional Miocárdico , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Estudios Retrospectivos , Intervención Coronaria Percutánea/efectos adversos , Infarto del Miocardio/etiología , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/diagnóstico , Angiografía Coronaria , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía
19.
Cardiovasc Revasc Med ; 53: 51-60, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37005105

RESUMEN

OBJECTIVES: This study sought to present an angiography-based computational model for serial assessment of superficial wall strain (SWS, dimensionless) of de-novo coronary stenoses treated with either bioresorbable scaffold (BRS) or drug-eluting stent (DES). BACKGROUND: A novel method for SWS allows the assessment of the mechanical status of arteries in-vivo, which may help for predicting cardiovascular outcomes. METHODS: Patients with arterial stenosis treated with BRS (n = 21) or DES (n = 21) were included from ABSORB Cohort B1 and AIDA trials. The SWS analyses were performed along with quantitative coronary angiography (QCA) at pre-PCI, post-PCI, and 5-year follow-up. Measurements of QCA and SWS parameters were quantified at the treated segment and adjacent 5-mm proximal and distal edges. RESULTS: Before PCI, the peak SWS on the 'to be treated' segment (0.79 ± 0.36) was significantly higher than at both virtual edges (0.44 ± 0.14 and 0.45 ± 0.21; both p < 0.001). The peak SWS in the treated segment significantly decreased by 0.44 ± 0.13 (p < 0.001). The surface area of high SWS decreased from 69.97mm2 to 40.08mm2 (p = 0.002). The peak SWS in BRS group decreased to a similar extent (p = 0.775) from 0.81 ± 0.36 to 0.41 ± 0.14 (p < 0.001), compared with DES group from 0.77 ± 0.39 to 0.47 ± 0.13 (p = 0.001). Relocation of high SWS to device edges was often observed in both groups after PCI (35 of 82 cases, 41.7 %). At follow-up of BRS, the peak SWS remained unchanged compared to post-PCI (0.40 ± 0.12 versus 0.36 ± 0.09, p = 0.319). CONCLUSION: Angiography-based SWS provided valuable information about the mechanical status of coronary arteries. Device implantation led to a significant decrease of SWS to a similar extent with either polymer-based scaffolds or permanent metallic stents.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Everolimus , Implantes Absorbibles , Intervención Coronaria Percutánea/efectos adversos , Vasos Coronarios/diagnóstico por imagen , Angiografía Coronaria , Resultado del Tratamiento , Diseño de Prótesis
20.
Eur Heart J Qual Care Clin Outcomes ; 9(5): 490-501, 2023 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-36001991

RESUMEN

AIMS: The aim of this study was to investigate the impact on 10-year survival of patient-reported anginal status at 1 year following percutaneous coronary intervention (PCI) or coronary artery bypass graft (CABG) in patients with left main coronary artery disease (LMCAD) and/or three-vessel CAD (3VD). METHODS AND RESULTS: In this post hoc analysis of the randomized SYNTAX Extended Survival study, patients were classified as having residual angina (RA) if their self-reported Seattle Angina Questionnaire angina frequency (SAQ-AF) scale was ≤90 at the 1-year follow-up post-revascularization with PCI or CABG. The primary endpoint of all-cause death at 10 years was compared between the RA and no-RA groups. A sensitivity analysis was performed using a 6-month SAQ-AF.At 1 year, 373 (26.1%) out of 1428 patients reported RA. Whilst RA at 1 year was an independent correlate of repeat revascularization at 5 years [18.3 vs. 11.5%; adjusted hazard ratio (HR): 1.54; 95% confidence interval (CI): 1.10-2.15], it was not associated with all-cause death at 10 years (22.1 vs. 21.6%; adjusted HR: 1.11; 95% CI: 0.83-1.47). These results were consistent when stratified by the modality of revascularization (PCI or CABG) or by anginal frequency. The sensitivity analysis replicating the analyses based on 6-month angina status resulted in similar findings. CONCLUSION: Among patients with LMCAD and/or 3VD, patient-reported RA at 1 year post-revascularization was independently associated with repeat revascularization at 5 years; however, it did not significantly increase 10-year mortality, irrespective of the primary modality of revascularization or severity of RA.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Puente de Arteria Coronaria/métodos , Angina de Pecho/epidemiología , Angina de Pecho/cirugía , Autoinforme
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA