Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Vasc Interv Radiol ; 34(7): 1157-1165.e8, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36972846

RESUMEN

PURPOSE: To investigate the real-world safety of paclitaxel (PTX)-coated devices for treating lower extremity peripheral artery disease using a commercial claims database. MATERIALS AND METHODS: Data from FAIR Health, the largest commercial claims data warehouse in the United States, were used for this study. The study consisted of patients who underwent femoropopliteal revascularization procedures between January 1, 2015, and December 31, 2019, with PTX and non-PTX devices. The primary outcome was 4-year survival following treatment. The secondary outcomes included 2-year survival, 2- and 4-year freedom from amputation, and repeat revascularization. Propensity score matching was used to minimize confounding, and the Kaplan-Meier methods were used to estimate survival. RESULTS: A total of 10,832 procedures were included in the analysis, including 4,962 involving PTX devices and 5,870 involving non-PTX devices. PTX devices were associated with a reduced hazard of death following treatment at 2 and 4 years (hazard ratio [HR], 0.74 [95% confidence interval {CI}, 0.69-0.79]; P <.05, and HR, 0.89 [95% CI, 0.77-1.02]; log-rank P =.018, respectively). The risk of amputation was also lower following treatment with PTX devices than with non-PTX devices at 2 and 4 years (HR, 0.82 [95% CI, 0.76-0.87]; P =.02, and HR, 0.77 [95% CI, 0.67-0.89]; log-rank P =.01, respectively). In addition, the odds of repeat revascularization were similar with PTX and non-PTX devices at 2 and 4 years. CONCLUSIONS: In the real-world commercial claims database, no short- or long-term signal for increased mortality or amputations was observed following treatment with PTX devices.


Asunto(s)
Fármacos Cardiovasculares , Stents Liberadores de Fármacos , Procedimientos Endovasculares , Enfermedad Arterial Periférica , Humanos , Paclitaxel/efectos adversos , Arteria Poplítea , Resultado del Tratamiento , Fármacos Cardiovasculares/efectos adversos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Arteria Femoral , Grado de Desobstrucción Vascular
2.
Circulation ; 144(22): 1750-1759, 2021 11 30.
Artículo en Inglés | MEDLINE | ID: mdl-34706555

RESUMEN

BACKGROUND: Chronic kidney disease is associated with adverse outcomes among patients with established cardiovascular disease (CVD) or diabetes. Commonly used medications to treat CVD are less effective among patients with reduced kidney function. METHODS: REDUCE-IT (Reduction of Cardiovascular Events with Icosapent Ethyl-Intervention Trial) was a multicenter, double-blind, placebo-controlled trial that randomly assigned statin-treated patients with elevated triglycerides (135-499 mg/dL) who had CVD or diabetes and 1 additional risk factor to treatment with icosapent ethyl (4 g daily) or placebo. Patients from REDUCE-IT were categorized by prespecified estimated glomerular filtration rate (eGFR) categories to analyze the effect of icosapent ethyl on the primary end point (composite of cardiovascular death, nonfatal myocardial infarction, nonfatal stroke, coronary revascularization, or unstable angina) and key secondary end point (a composite of cardiovascular death, nonfatal myocardial infarction, or nonfatal stroke). RESULTS: Among the 8179 REDUCE-IT patients, median baseline eGFR was 75 mL·min-1·1.73 m-2 (range, 17-123 mL·min-1·1.73 m-2). There were no meaningful changes in median eGFR for icosapent ethyl versus placebo across study visits. Treatment with icosapent ethyl led to consistent reduction in both the primary and key secondary composite end points across baseline eGFR categories. Patients with eGFR <60 mL·min-1·1.73 m-2 treated with icosapent ethyl had the largest absolute and similar relative risk reduction for the primary composite end point (icosapent ethyl versus placebo, 21.8% versus 28.9%; hazard ratio [HR], 0.71 [95% CI, 0.59-0.85]; P=0.0002) and key secondary composite end point (16.8% versus 22.5%; HR 0.71 [95% CI, 0.57-0.88]; P=0.001). The numeric reduction in cardiovascular death was greatest in the eGFR <60 mL·min-1·1.73 m-2 group (icosapent ethyl: 7.6%; placebo: 10.6%; HR, 0.70 [95% CI, 0.51-0.95]; P=0.02). Although patients with eGFR <60 mL·min-1·1.73 m-2 treated with icosapent ethyl had the highest numeric rates of atrial fibrillation/flutter (icosapent ethyl: 4.2%; placebo 3.0%; HR 1.42 [95% CI, 0.86-2.32]; P=0.17) and serious bleeding (icosapent ethyl: 5.4%; placebo 3.6%; HR, 1.40 [95% CI, 0.90-2.18]; P=0.13), HRs for atrial fibrillation/flutter and serious bleeding were similar across eGFR categories (P-interaction for atrial fibrillation/flutter=0.92; P-interaction for serious bleeding=0.76). CONCLUSIONS: In REDUCE-IT, icosapent ethyl reduced fatal and nonfatal ischemic events across the broad range of baseline eGFR categories. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01492361.


Asunto(s)
Enfermedades Cardiovasculares , Ácido Eicosapentaenoico/análogos & derivados , Tasa de Filtración Glomerular/efectos de los fármacos , Insuficiencia Renal Crónica , Anciano , Enfermedades Cardiovasculares/complicaciones , Enfermedades Cardiovasculares/tratamiento farmacológico , Enfermedades Cardiovasculares/fisiopatología , Método Doble Ciego , Ácido Eicosapentaenoico/administración & dosificación , Ácido Eicosapentaenoico/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia Renal Crónica/etiología , Insuficiencia Renal Crónica/fisiopatología , Insuficiencia Renal Crónica/prevención & control
3.
N Engl J Med ; 376(6): 526-535, 2017 02 09.
Artículo en Inglés | MEDLINE | ID: mdl-28121489

RESUMEN

BACKGROUND: The process of assuring the safety of medical devices is constrained by reliance on voluntary reporting of adverse events. We evaluated a strategy of prospective, active surveillance of a national clinical registry to monitor the safety of an implantable vascular-closure device that had a suspected association with increased adverse events after percutaneous coronary intervention (PCI). METHODS: We used an integrated clinical-data surveillance system to conduct a prospective, propensity-matched analysis of the safety of the Mynx vascular-closure device, as compared with alternative approved vascular-closure devices, with data from the CathPCI Registry of the National Cardiovascular Data Registry. The primary outcome was any vascular complication, which was a composite of access-site bleeding, access-site hematoma, retroperitoneal bleeding, or any vascular complication requiring intervention. Secondary safety end points were access-site bleeding requiring treatment and postprocedural blood transfusion. RESULTS: We analyzed data from 73,124 patients who had received Mynx devices after PCI procedures with femoral access from January 1, 2011, to September 30, 2013. The Mynx device was associated with a significantly greater risk of any vascular complication than were alternative vascular-closure devices (absolute risk, 1.2% vs. 0.8%; relative risk, 1.59; 95% confidence interval [CI], 1.42 to 1.78; P<0.001); there was also a significantly greater risk of access-site bleeding (absolute risk, 0.4% vs. 0.3%; relative risk, 1.34; 95% CI, 1.10 to 1.62; P=0.001) and transfusion (absolute risk, 1.8% vs. 1.5%; relative risk, 1.23; 95% CI, 1.13 to 1.34; P<0.001). The initial alerts occurred within the first 12 months of monitoring. Relative risks were greater in three prespecified high-risk subgroups: patients with diabetes, those 70 years of age or older, and women. All safety alerts were confirmed in an independent sample of 48,992 patients from April 1, 2014, to September 30, 2015. CONCLUSIONS: A strategy of prospective, active surveillance of a clinical registry rapidly identified potential safety signals among recipients of an implantable vascular-closure device, with initial alerts occurring within the first 12 months of monitoring. (Funded by the Food and Drug Administration and others.).


Asunto(s)
Seguridad de Equipos , Intervención Coronaria Percutánea/instrumentación , Dispositivos de Cierre Vascular/efectos adversos , Anciano , Diseño de Equipo , Seguridad de Equipos/estadística & datos numéricos , Femenino , Hemorragia/epidemiología , Hemorragia/etiología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Vigilancia de la Población , Estudios Prospectivos , Sistema de Registros , Riesgo , Medición de Riesgo/métodos
4.
Arterioscler Thromb Vasc Biol ; 39(4): 546-557, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30760019

RESUMEN

Antiplatelet therapies are an essential tool to reduce the risk of developing clinically apparent atherothrombotic disease and are a mainstay in the therapy of patients who have established cardiovascular, cerebrovascular, and peripheral artery disease. Strategies to intensify antiplatelet regimens are limited by concomitant increases in clinically significant bleeding. The development of novel antiplatelet therapies targeting additional receptor and signaling pathways, with a focus on maintaining antiplatelet efficacy while preserving hemostasis, holds tremendous potential to improve outcomes among patients with atherothrombotic diseases.


Asunto(s)
Aterosclerosis/tratamiento farmacológico , Inhibidores de Agregación Plaquetaria/uso terapéutico , Trombofilia/tratamiento farmacológico , Humanos , Isquemia/prevención & control , Inhibidores de Agregación Plaquetaria/clasificación , Inhibidores de Agregación Plaquetaria/farmacología
5.
Catheter Cardiovasc Interv ; 90(3): 476-479, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28398633

RESUMEN

Ultrasound-assisted catheter-directed thrombolysis therapy has emerged more recently as a management strategy for patients with intermediate risk pulmonary embolism and has shown promising results in clinical trials by early reversal of right ventricle dilation, reduced pulmonary hypertension, and decreased anatomic thrombus burden. This therapeutic strategy requires a small fraction of the systemic fibrinolytic dose and is therefore associated with a reduced bleeding risk. Although intracranial hemorrhage has not been reported in clinical trials, it is a possible complication. Here we report the first case of intracranial hemorrhage related to the use of EkoSonic™ Endovascular System directed thrombolysis in a patient with large bilateral pulmonary embolism without any identifiable bleeding risks. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Procedimientos Endovasculares , Fibrinolíticos/efectos adversos , Hemorragias Intracraneales/inducido químicamente , Embolia Pulmonar/tratamiento farmacológico , Terapia Trombolítica , Activador de Tejido Plasminógeno/metabolismo , Dispositivos de Acceso Vascular , Anciano de 80 o más Años , Angiografía por Tomografía Computarizada , Ecocardiografía , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Diseño de Equipo , Resultado Fatal , Femenino , Fibrinolíticos/administración & dosificación , Humanos , Hemorragias Intracraneales/diagnóstico por imagen , Hemorragias Intracraneales/terapia , Embolia Pulmonar/diagnóstico por imagen , Factores de Riesgo , Terapia Trombolítica/efectos adversos , Terapia Trombolítica/instrumentación , Activador de Tejido Plasminógeno/administración & dosificación , Resultado del Tratamiento , Ultrasonografía Intervencional
8.
Catheter Cardiovasc Interv ; 86(1): 49-50, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26097055

RESUMEN

This study demonstrates that in a single center, single operator experience, ulnar artery catheterization is feasible, though even compared to radial access, a significant learning curve remains. Although ulnar access is a reasonable alternative approach to catheterization, the true benefits of ulnar access, compared to radial are unclear. Further large randomized multicenter, multi-operator trials are needed to assess the true feasibility and benefit of ulnar artery catheterization.


Asunto(s)
Cateterismo Cardíaco/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Arteria Cubital , Femenino , Humanos , Masculino
10.
Int J Cardiol Heart Vasc ; 44: 101165, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36820391

RESUMEN

Background: Surgical therapy has been a long-standing option for valvular heart disease, in patients with history of cancer, it carries an increased risk of complications. Objectives: Transcatheter edge-to-edge repair (TEER) for mitral regurgitation, represents a less invasive option. However, patients with history of cancer have generally been excluded from trials. Methods: A retrospective cohort analysis was performed on de-identified, aggregate patient data from the TriNetX research network. Patients 18 ≥ years of age, who had undergone TEER between January 1, 2013 and May 19, 2021, were identified using the CPT codes and divided into two cohorts based on a history of cancer. Subgroup analysis was performed based on history of systemic antineoplastic therapy. Odds ratio and log-rank test were used to compare the outcomes over 1 and 12-months. Results: In matched cohorts (503 patients in each, mean age 77.7 years, men 55 vs 58 %, white 84 vs 87 % in non-cancer and cancer cohorts respectively), the risk of heart failure exacerbation, all-cause mortality and all-cause hospitalizations were similar at 1 and 12 months among patients undergoing TEER. Risk of major complications (ischemic stroke, blood product transfusion and cardiac tamponade) were also similar. In the cancer cohort, hematologic/lymphoid malignancies were the most common (28.0 %) and 12.5 % patients had a history of metastatic cancer. There was no significant difference in heart failure exacerbation or all-cause mortality based on history of systemic antineoplastic therapy. Conclusions: Overall outcomes following TEER are similar in patients with a history of cancer and should be considered in selected patients in this population.

11.
Prog Cardiovasc Dis ; 69: 47-53, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34838788

RESUMEN

Heart failure (HF) is associated with considerable morbidity and mortality. The increasing prevalence of HF and inpatient HF hospitalization has a considerable burden on healthcare cost and utilization. The recognition that hemodynamic changes in pulmonary artery pressure (PAP) and left atrial pressure precede the signs and symptoms of HF has led to interest in hemodynamic guided HF therapy as an approach to allow earlier intervention during a heart failure decompensation. Remote patient monitoring (RPM) utilizing telecommunication, cardiac implantable electronic device parameters and implantable hemodynamic monitors (IHM) have largely failed to demonstrate favorable outcomes in multicenter trials. However, one positive randomized clinical trial testing the CardioMEMS device (followed by Food and Drug Administration approval) has generated renewed interest in PAP monitoring in the HF population to decrease hospitalization and improve quality of life. The COVID-19 pandemic has also stirred a resurgence in the utilization of telehealth to which RPM using IHM may be complementary. The cost effectiveness of these monitors continues to be a matter of debate. Future iterations of devices aim to be smaller, less burdensome for the patient, less dependent on patient compliance, and less cumbersome for health care providers with the integration of artificial intelligence coupled with sophisticated data management and interpretation tools. Currently, use of IHM may be considered in advanced heart failure patients with the support of structured programs.


Asunto(s)
Presión Arterial , Función del Atrio Izquierdo , Presión Atrial , Insuficiencia Cardíaca/diagnóstico , Monitorización Hemodinámica/instrumentación , Arteria Pulmonar/fisiopatología , Tecnología de Sensores Remotos/instrumentación , Telemedicina/instrumentación , Algoritmos , COVID-19 , Difusión de Innovaciones , Diseño de Equipo , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador
12.
JACC Cardiovasc Interv ; 14(23): 2598-2609, 2021 12 13.
Artículo en Inglés | MEDLINE | ID: mdl-34887051

RESUMEN

OBJECTIVES: This study sought to determine the safety and efficacy of paclitaxel (PTX) devices in the treatment of peripheral artery disease involving the femoropopliteal artery. BACKGROUND: A meta-analysis of PTX devices for the treatment of femoropopliteal artery disease reported a mortality signal. METHODS: This was a multicenter cohort study using an integrated clinical data surveillance system to conduct a prospective, propensity score-matched survival analysis of 2,456 patients in the Society for Vascular Surgery Vascular Quality Initiative from January 2017 to May 2020. The study compared PTX drug-coated balloon angioplasty versus percutaneous transluminal balloon angioplasty, PTX drug-eluting stents versus bare-metal stents, and any PTX device versus any non-PTX device. The primary outcome was 2-year survival. Secondary endpoints were successful ambulation and interventional success. RESULTS: Treatment with any PTX device versus any non-PTX device was associated with increased 2-year survival (89.5% vs 86.7%; HR: 0.79; 95% CI: 0.72-0.87; P = 0.004), improved interventional success (81.6% vs 77.6%; HR: 0.82; 95% CI: 0.74-0.91; P < 0.001), and higher rates of independent ambulation at 1 year (86.0% vs 83.4%; HR: 0.85; 95% CI: 0.79-0.91; P = 0.008). Treatment with PTX drug-coated balloon angioplasty was associated with improved survival at 2 years (88.9% vs 85.7%; HR: 0.77; 95% CI: 0.70-0.86; P = 0.005), while PTX drug-eluting stent therapy was associated with similar survival compared with bare-metal stent therapy (91.3% vs 89.6%; HR: 0.84; 95% CI: 0.70-1.01; P = 0.36). CONCLUSIONS: In this prospective, active surveillance of a national clinical registry, PTX-containing devices were associated with increased survival at 2 years and improved clinical outcomes at 1 year. (VQI DELTA Paclitaxel Device Safety Analysis [VQI-PTX]; NCT04110288).


Asunto(s)
Angioplastia de Balón , Fármacos Cardiovasculares , Stents Liberadores de Fármacos , Enfermedad Arterial Periférica , Estudios de Cohortes , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Humanos , Estudios Multicéntricos como Asunto , Paclitaxel , Enfermedad Arterial Periférica/tratamiento farmacológico , Enfermedad Arterial Periférica/terapia , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Grado de Desobstrucción Vascular
14.
Circ Cardiovasc Qual Outcomes ; 13(4): e006105, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32283971

RESUMEN

BACKGROUND: Several defibrillator leads have been recalled due to early lead failure leading to significant patient harm. Confirming the safety of contemporary defibrillator leads is essential to optimizing treatment for patients receiving implantable cardioverter-defibrillators (ICDs). We therefore sought to assess the comparative long-term safety of the 4 most commonly implanted ICD leads within the National Cardiovascular Data Registry ICD Registry. METHODS AND RESULTS: A propensity-matched survival analysis of the ICD Registry was performed evaluating 4 contemporary ICD leads in patients receiving an ICD system for the first time. All patients in the ICD Registry aged ≥18 years who underwent an implant of an ICD between April 1, 2011 and March 31, 2016 were included. Monitoring of safety began with ICD implant and continued up to 5 years. A meaningful difference in ICD failure rate was defined as twice (or more) the lead failure rate observed in the propensity-matched comparator patients. Among the 374 132 patients who received a new ICD implant, no safety alerts were triggered for the primary safety end point of lead failure for any of the high energy leads studied. Estimated rates of freedom from lead failure at 5 years ranged from 97.7% to 98.9% for the 4 high-energy leads of interest. CONCLUSIONS: Though limited by incomplete long-term outcomes ascertainment, active surveillance of the ICD Registry suggests that there were no meaningful differences in the rate of ICD high-energy lead survival for the 4 most commonly used high-energy ICD leads.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Falla de Prótesis , Anciano , Cardioversión Eléctrica/efectos adversos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Vigilancia de Productos Comercializados , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
15.
BMJ Surg Interv Health Technol ; 2(1): e000047, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-35047794

RESUMEN

OBJECTIVES: The CathPCI Data Extraction and Longitudinal Trend Analysis study was designed to determine the feasibility of conducting prospective surveillance of a large national registry to perform comparative safety analyses of medical devices. We sought to determine whether the complementary use of retrospective case data could improve safety signal detection time. DESIGN: We performed a simulated surveillance study of the comparative safety of the Mynx vascular closure device (VCD) with propensity score matched alternate VCD recipients, using both retrospective and prospective cohort data. SETTING: Centers within the USA using the National Cardiovascular Data Registry (NCDR) CathPCI Registry. PARTICIPANTS: Percutaneous coronary intervention cases captured within the NCDR CathPCI Registry from July 1, 2009 to September 30, 2013 were included in the analysis. INTERVENTIONS: None. MAIN OUTCOME MEASURES: Absolute and relative risk (RR) of any vascular complication (a composite of bleeding at access site, hematoma at access site, retroperitoneal bleeding, and other vascular complications requiring treatment); time to signal detection. RESULTS: A safety alert was detected for the primary outcome of "any vascular complication" after 15 months of surveillance and was sustained for the study duration (absolute risk of any vascular complication, 1.20% vs 0.73%, RR, 1.63; 95% CI 1.50 to 1.79; p<0.001). The safety signal was identified 12 months earlier with the use of retrospective case data than during the initial study. CONCLUSIONS: Prospective, active surveillance of cardiovascular registries is feasible to perform comparative analyses of medical devices. Retrospective data may complement prospective surveillance to improve time to signal detection, indicating the need for earlier prospective application of safety surveillance for devices new to the market.

17.
Circ Cardiovasc Qual Outcomes ; 12(2): e004666, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30764652

RESUMEN

Background Current strategies for ensuring the postmarket safety of medical devices are limited by small sample size and reliance on voluntary reporting of adverse events. Prospective, active surveillance of clinical registries may provide early warnings in the postmarket evaluation of medical device safety but has not been demonstrated in national clinical data registries. Methods and Results The CathPCI DELTA (Data Extraction and Longitudinal Trend Analysis) study was designed to assess the feasibility of prospective, active safety surveillance of medical devices within a national cardiovascular registry. We sought to assess the ability of our surveillance strategy to avoid false safety alerts by conducting an active safety surveillance study of aspiration thrombectomy catheters using data within the National Cardiovascular Data Registry CathPCI registry, where no difference in safety outcomes were anticipated for the primary in-hospital safety outcome of death and major adverse cardiovascular events (MACE). We performed a propensity-matched analysis of 5 aspiration thrombectomy catheter devices used during percutaneous coronary intervention among 95 925 patients presenting with ST-segment-elevation myocardial infarction between January 1, 2011 and September 30, 2013. After 33 months of surveillance, no safety alerts were triggered for the primary safety endpoints of death or MACE, with no between-catheter differences observed. The absolute risk of death during acute hospitalization ranged from 5.11% to 5.32% among the most commonly used aspiration thrombectomy catheter devices, with relative risks for death ranging from 0.96 to 1.03. The absolute risk of MACE ranged from 9.78% to 10.18%, with relative risks for MACE ranging from 0.99 to 1.02. There were no statistically significant differences in the rates of death or MACE between any of the aspiration thrombectomy catheter devices analyzed. Conclusions The CathPCI DELTA study demonstrates that prospective, active safety surveillance of national clinical registries is feasible to provide near-real-time safety assessments of new medical devices.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Intervención Coronaria Percutánea/instrumentación , Vigilancia de Productos Comercializados , Trombectomía/instrumentación , Anciano , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Diseño de Equipo , Falla de Equipo , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Sistema de Registros , Medición de Riesgo , Trombectomía/efectos adversos , Trombectomía/mortalidad , Resultado del Tratamiento
18.
Endocrinol Metab Clin North Am ; 47(1): 223-235, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29407053

RESUMEN

Cardiovascular disease (CVD) is a significant cause of morbidity and mortality among patients with diabetes mellitus (DM). Increased platelet reactivity among patients with DM contributes to disproportionately high levels of atherothrombotic CVD. Consequently, there has been tremendous interest in exploring the role of antiplatelet therapies in DM to reduce the development of and frequency of future cardiovascular events.


Asunto(s)
Aspirina/farmacología , Enfermedades Cardiovasculares , Complicaciones de la Diabetes , Inhibidores de Agregación Plaquetaria/farmacología , Enfermedades Cardiovasculares/tratamiento farmacológico , Enfermedades Cardiovasculares/prevención & control , Complicaciones de la Diabetes/tratamiento farmacológico , Complicaciones de la Diabetes/prevención & control , Humanos
19.
Interv Cardiol Clin ; 6(1): 25-37, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27886820

RESUMEN

Dual antiplatelet therapy (DAPT) is an essential component of treatment in patients with coronary artery disease treated with percutaneous coronary intervention (PCI). Recommendations for duration of DAPT after PCI should consider patient-specific risk, clinical presentation, stent characteristics, and procedural factors. Prolonged DAPT results in a reduction of stent thrombosis (ST) and myocardial infarction (MI) at the cost of increased bleeding. Studies of shorter-duration DAPT demonstrate similar mortality, MI, ST, and less bleeding when compared with longer DAPT duration. We review current evidence for strategies of prolonged DAPT and abbreviated DAPT following PCI.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/administración & dosificación , Cuidados Posoperatorios/métodos , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Esquema de Medicación , Quimioterapia Combinada , Humanos
20.
Cardiovasc Revasc Med ; 18(6): 445-446, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28404227

RESUMEN

A 63 year old male presents with anterior ST elevation myocardial infarction. Two years prior he had PCI with DES to the proximal left anterior descending (LAD) and circumflex arteries following an abnormal stress test. Clopidogrel was discontinued several weeks prior to this presentation.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/cirugía , Stents Liberadores de Fármacos , Infarto del Miocardio/terapia , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/métodos , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA