1.
N Engl J Med ; 390(15): 1382-1393, 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38587239

RESUMEN

BACKGROUND: The effects of temporary mechanical circulatory support with a microaxial flow pump on mortality among patients with ST-segment elevation myocardial infarction (STEMI) complicated by cardiogenic shock remains unclear. METHODS: In an international, multicenter, randomized trial, we assigned patients with STEMI and cardiogenic shock to receive a microaxial flow pump (Impella CP) plus standard care or standard care alone. The primary end point was death from any cause at 180 days. A composite safety end point was severe bleeding, limb ischemia, hemolysis, device failure, or worsening aortic regurgitation. RESULTS: A total of 360 patients underwent randomization, of whom 355 were included in the final analysis (179 in the microaxial-flow-pump group and 176 in the standard-care group). The median age of the patients was 67 years, and 79.2% were men. Death from any cause occurred in 82 of 179 patients (45.8%) in the microaxial-flow-pump group and in 103 of 176 patients (58.5%) in the standard-care group (hazard ratio, 0.74; 95% confidence interval [CI], 0.55 to 0.99; P = 0.04). A composite safety end-point event occurred in 43 patients (24.0%) in the microaxial-flow-pump group and in 11 (6.2%) in the standard-care group (relative risk, 4.74; 95% CI, 2.36 to 9.55). Renal-replacement therapy was administered to 75 patients (41.9%) in the microaxial-flow-pump group and to 47 patients (26.7%) in the standard-care group (relative risk, 1.98; 95% CI, 1.27 to 3.09). CONCLUSIONS: The routine use of a microaxial flow pump with standard care in the treatment of patients with STEMI-related cardiogenic shock led to a lower risk of death from any cause at 180 days than standard care alone. The incidence of a composite of adverse events was higher with the use of the microaxial flow pump. (Funded by the Danish Heart Foundation and Abiomed; DanGer Shock ClinicalTrials.gov number, NCT01633502.).


Asunto(s)
Corazón Auxiliar , Infarto del Miocardio con Elevación del ST , Choque Cardiogénico , Anciano , Femenino , Humanos , Masculino , Corazón Auxiliar/efectos adversos , Incidencia , Choque Cardiogénico/etiología , Choque Cardiogénico/mortalidad , Choque Cardiogénico/cirugía , Infarto del Miocardio con Elevación del ST/complicaciones , Infarto del Miocardio con Elevación del ST/mortalidad , Infarto del Miocardio con Elevación del ST/terapia , Resultado del Tratamiento , Circulación Asistida/efectos adversos , Circulación Asistida/instrumentación , Circulación Asistida/métodos
2.
N Engl J Med ; 389(15): 1368-1379, 2023 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-37634190

RESUMEN

BACKGROUND: In patients with ST-segment elevation myocardial infarction (STEMI) with multivessel coronary artery disease, the time at which complete revascularization of nonculprit lesions should be performed remains unknown. METHODS: We performed an international, open-label, randomized, noninferiority trial at 37 sites in Europe. Patients in a hemodynamically stable condition who had STEMI and multivessel coronary artery disease were randomly assigned to undergo immediate multivessel percutaneous coronary intervention (PCI; immediate group) or PCI of the culprit lesion followed by staged multivessel PCI of nonculprit lesions within 19 to 45 days after the index procedure (staged group). The primary end point was a composite of death from any cause, nonfatal myocardial infarction, stroke, unplanned ischemia-driven revascularization, or hospitalization for heart failure at 1 year after randomization. The percentages of patients with a primary or secondary end-point event are provided as Kaplan-Meier estimates at 6 months and at 1 year. RESULTS: We assigned 418 patients to undergo immediate multivessel PCI and 422 to undergo staged multivessel PCI. A primary end-point event occurred in 35 patients (8.5%) in the immediate group as compared with 68 patients (16.3%) in the staged group (risk ratio, 0.52; 95% confidence interval, 0.38 to 0.72; P<0.001 for noninferiority and P<0.001 for superiority). Nonfatal myocardial infarction and unplanned ischemia-driven revascularization occurred in 8 patients (2.0%) and 17 patients (4.1%), respectively, in the immediate group and in 22 patients (5.3%) and 39 patients (9.3%), respectively, in the staged group. The risk of death from any cause, the risk of stroke, and the risk of hospitalization for heart failure appeared to be similar in the two groups. A total of 104 patients in the immediate group and 145 patients in the staged group had a serious adverse event. CONCLUSIONS: Among patients in hemodynamically stable condition with STEMI and multivessel coronary artery disease, immediate multivessel PCI was noninferior to staged multivessel PCI with respect to the risk of death from any cause, nonfatal myocardial infarction, stroke, unplanned ischemia-driven revascularization, or hospitalization for heart failure at 1 year. (Supported by Boston Scientific; MULTISTARS AMI ClinicalTrials.gov number, NCT03135275.).


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/cirugía , Europa (Continente) , Insuficiencia Cardíaca/etiología , Infarto del Miocardio/etiología , Infarto del Miocardio/cirugía , Revascularización Miocárdica/efectos adversos , Revascularización Miocárdica/métodos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/mortalidad , Infarto del Miocardio con Elevación del ST/etiología , Infarto del Miocardio con Elevación del ST/mortalidad , Infarto del Miocardio con Elevación del ST/cirugía , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento , Tiempo de Tratamiento
3.
Clin Infect Dis ; 78(1): 179-187, 2024 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-37552784

RESUMEN

BACKGROUND: Scarce data are available comparing infective endocarditis (IE) following surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). This study aimed to compare the clinical presentation, microbiological profile, management, and outcomes of IE after SAVR versus TAVR. METHODS: Data were collected from the "Infectious Endocarditis after TAVR International" (enrollment from 2005 to 2020) and the "International Collaboration on Endocarditis" (enrollment from 2000 to 2012) registries. Only patients with an IE affecting the aortic valve prosthesis were included. A 1:1 paired matching approach was used to compare patients with TAVR and SAVR. RESULTS: A total of 1688 patients were included. Of them, 602 (35.7%) had a surgical bioprosthesis (SB), 666 (39.5%) a mechanical prosthesis, 70 (4.2%) a homograft, and 350 (20.7%) a transcatheter heart valve. In the SAVR versus TAVR matched population, the rate of new moderate or severe aortic regurgitation was higher in the SB group (43.4% vs 13.5%; P < .001), and fewer vegetations were diagnosed in the SB group (62.5% vs 82%; P < .001). Patients with an SB had a higher rate of perivalvular extension (47.9% vs 27%; P < .001) and Staphylococcus aureus was less common in this group (13.4% vs 22%; P = .033). Despite a higher rate of surgery in patients with SB (44.4% vs 27.3%; P < .001), 1-year mortality was similar (SB: 46.5%; TAVR: 44.8%; log-rank P = .697). CONCLUSIONS: Clinical presentation, type of causative microorganism, and treatment differed between patients with an IE located on SB compared with TAVR. Despite these differences, both groups exhibited high and similar mortality at 1-year follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Endocarditis Bacteriana , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversos , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Factores de Riesgo
4.
Int J Mol Sci ; 25(12)2024 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-38928324

RESUMEN

Heart failure with preserved ejection fraction (HFpEF) is characterized by biomechanically dysfunctional cardiomyocytes. Underlying cellular changes include perturbed myocardial titin expression and titin hypophosphorylation leading to titin filament stiffening. Beside these well-studied alterations at the cardiomyocyte level, exercise intolerance is another hallmark of HFpEF caused by molecular alterations in skeletal muscle (SKM). Currently, there is a lack of data regarding titin modulation in the SKM of HFpEF. Therefore, the aim of the present study was to analyze molecular alterations in limb SKM (tibialis anterior (TA)) and in the diaphragm (Dia), as a more central SKM, with a focus on titin, titin phosphorylation, and contraction-regulating proteins. This study was performed with muscle tissue, obtained from 32-week old female ZSF-1 rats, an established a HFpEF rat model. Our results showed a hyperphosphorylation of titin in limb SKM, based on enhanced phosphorylation at the PEVK region, which is known to lead to titin filament stiffening. This hyperphosphorylation could be reversed by high-intensity interval training (HIIT). Additionally, a negative correlation occurring between the phosphorylation state of titin and the muscle force in the limb SKM was evident. For the Dia, no alterations in the phosphorylation state of titin could be detected. Supported by data of previous studies, this suggests an exercise effect of the Dia in HFpEF. Regarding the expression of contraction regulating proteins, significant differences between Dia and limb SKM could be detected, supporting muscle atrophy and dysfunction in limb SKM, but not in the Dia. Altogether, these data suggest a correlation between titin stiffening and the appearance of exercise intolerance in HFpEF, as well as a differential regulation between different SKM groups.


Asunto(s)
Conectina , Diafragma , Modelos Animales de Enfermedad , Insuficiencia Cardíaca , Músculo Esquelético , Animales , Insuficiencia Cardíaca/metabolismo , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/patología , Ratas , Diafragma/metabolismo , Diafragma/fisiopatología , Diafragma/patología , Conectina/metabolismo , Fosforilación , Femenino , Músculo Esquelético/metabolismo , Músculo Esquelético/fisiopatología , Músculo Esquelético/patología , Volumen Sistólico , Contracción Muscular , Condicionamiento Físico Animal , Proteínas Musculares/metabolismo
5.
Clin Infect Dis ; 76(6): 1003-1012, 2023 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-36331961

RESUMEN

BACKGROUND: Echocardiography is the primary imaging modality for diagnosis of infective endocarditis (IE) in prosthetic valve endocarditis (PVE) including IE after transcatheter aortic valve implantation (TAVI). This study aimed to evaluate the characteristics and clinical outcomes of patients with absent compared with evident echocardiographic signs of TAVI-IE. METHODS: Patients with definite TAVI-IE derived from the Infectious Endocarditis after TAVI International Registry were investigated comparing those with absent and evident echocardiographic signs of IE defined as vegetation, abscess, pseudo-aneurysm, intracardiac fistula, or valvular perforation or aneurysm. RESULTS: Among 578 patients, 87 (15.1%) and 491 (84.9%) had absent (IE-neg) and evident (IE-pos) echocardiographic signs of IE, respectively. IE-neg were more often treated via a transfemoral access with a self-expanding device and had higher rates of peri-interventional complications (eg, stroke, major vascular complications) during the TAVI procedure (P < .05 for all). IE-neg had higher rates of IE caused by Staphylococcus aureus (33.7% vs 23.2%; P = .038) and enterococci (37.2% vs 23.8%; P = .009) but lower rates of coagulase-negative staphylococci (4.7% vs 20.0%, P = .001). IE-neg was associated with the same dismal prognosis for in-hospital mortality in a multivariate binary regression analysis (odds ratio: 1.51; 95% confidence interval [CI]: .55-4.12) as well as a for 1-year mortality in Cox regression analysis (hazard ratio: 1.10; 95% CI: .67-1.80). CONCLUSIONS: Even with negative echocardiographic imaging, patients who have undergone TAVI and presenting with positive blood cultures and symptoms of infection are a high-risk patient group having a reasonable suspicion of IE and the need for an early treatment initiation.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Infecciones Relacionadas con Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Incidencia , Factores de Riesgo , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Endocarditis/diagnóstico por imagen , Endocarditis/epidemiología , Ecocardiografía
7.
Eur Heart J Suppl ; 25(Suppl I): I44-I48, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38093769

RESUMEN

Randomized studies attempting to prove benefit of mechanical circulatory support in cardiogenic shock have failed to reduce the risk of death. Further, both registry and randomized data suggest increased rates of serious complications associated with these devices. This last review in the supplement discusses current evidence and provides a perspective on how the scientific community could advance cardiogenic shock research focused on mechanical circulatory support.

8.
Eur Heart J Suppl ; 25(Suppl I): I39-I43, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38093770

RESUMEN

The additional implantation of a micro-axial flow pump (mAFP) in patients receiving extracorporeal life support by a veno-arterial extracorporeal membrane oxygenation (V-A ECMO) for cardiogenic shock (CS) has gained interest in recent years. Thus far, retrospective propensity score-matched studies, case series, and meta-analyses have consistently shown an improved survival in patients treated with the so-called ECMELLA concept. The pathophysiological context is based on the modification of V-A ECMO-related side effects and the additive benefit of myocardial unloading. From this point of view, knowledge and detection of these pathophysiological mechanisms are of utmost importance to successfully manage mechanical circulatory support in CS. In this article, we describe best practices for the indication of the two devices as well as escalation and de-escalation approaches including implantation and explantation strategies that are key for success.

9.
Eur Heart J Suppl ; 25(Suppl I): I11-I18, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38093767

RESUMEN

Cardiogenic shock (CS) is a complex clinical syndrome with a high risk of mortality. The recent, rapid development of temporary mechanical circulatory support (tMCS) has altered CS treatment. While catecholamines remain the cornerstone of CS therapy, tMCS usage has increased. According to shock severity, different treatment strategies including catecholamines alone, catecholamines and tMCS, or multiple tMCS might be used. State-of-the-art implantation techniques are necessary to avoid complications linked to the invasive nature of tMCS. In particular, bleeding and access-site complications might counteract the potential haemodynamic benefit of a percutaneous ventricular assist device. In this review, we describe the role of catecholamines in CS treatment and present the different tMCS devices with an explanation on how to use them according to CS aetiology and severity. Finally, an overview of the best practice for device implantation is provided.

10.
Clin Infect Dis ; 75(4): 638-646, 2022 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-34894124

RESUMEN

BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; P = .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; P < .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, P < .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padj < 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.


Asunto(s)
Aneurisma Falso , Endocarditis Bacteriana , Endocarditis , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Absceso , Aneurisma Falso/complicaciones , Aneurisma Falso/cirugía , Coagulasa , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Humanos , Insuficiencia Renal Crónica/complicaciones , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
11.
Eur Heart J Suppl ; 24(Suppl J): J4-J10, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36518889

RESUMEN

Percutaneous mechanical circulatory support (pMCS) is increasingly used in patients with poor left-ventricular (LV) function undergoing elective high-risk percutaneous coronary interventions (HR-PCIs). These patients are often in critical condition and not suitable candidates for coronary artery bypass graft surgery. For the definition of HR-PCI, there is a growing consensus that multiple factors must be considered to define the complexity of PCI. These include haemodynamic status, left-ventricular ejection fraction, clinical characteristics, and concomitant diseases, as well as the complexity of the coronary anatomy/lesions. Although haemodynamic support by percutaneous LV assist devices is commonly adopted in HR-PCI (protected PCI), there are no clear guideline recommendations for indication due to limited published data. Therefore, decisions to use a nonsurgical, minimally invasive procedure in HR-PCI patients should be based on a risk-benefit assessment by a multidisciplinary team. Here, the current evidence and indications for protected PCI will be discussed.

12.
Eur Heart J Suppl ; 24(Suppl J): J17-J24, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36518893

RESUMEN

Interest in the use of percutaneous left ventricular assist devices (p-LVADs) for patients undergoing high-risk percutaneous coronary intervention (PCI) is growing rapidly. The Impella™ (Abiomed Inc.) is a catheter-based continuous micro-axial flow pump that preserves haemodynamic support during high-risk PCI. Anticoagulation is required to counteract the activation of the coagulation system by the patient's procoagulant state and the foreign-body surface of the pump. Excessive anticoagulation and the effect of dual antiplatelet therapy (DAPT) increase the risk of bleeding. Inadequate anticoagulation leads to thrombus formation and device dysfunction. The precarious balance between bleeding and thrombosis in patients with p-LVAD support is often the primary reason that patients' outcomes are jeopardized. In this chapter, we will discuss anticoagulation strategies and anticoagulant management in the setting of protected PCI. This includes anticoagulant therapy with unfractionated heparin, direct thrombin inhibitors, DAPT, purge blockage prevention by bicarbonate-based purge solution, and monitoring by activated clotting time, partial thromboplastin time, as well as anti-factor Xa levels. Here, we provide a standardized approach to the management of peri-interventional anticoagulation in patients undergoing protected PCI.

13.
Eur Heart J Suppl ; 24(Suppl J): J30-J36, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36518894

RESUMEN

Protected percutaneous coronary intervention is considered a life-saving procedure for high-risk patients. Therefore it is important that the interventional cardiology team is prepared, the procedure is planned, and potential complications, as well as bail out strategies are considered. Throughout the procedure, it is critical to monitor the patient to identify any early signs of deterioration or changes in patient well-being to avoid any potential complications.

14.
J Card Surg ; 37(12): 4654-4661, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36273424

RESUMEN

BACKGROUND: "valve-in-valve" TAVR (VIV-TAVR) is established and provides good initial clinical and hemodynamic outcomes. Lacking long-term durability data baffle the expand to lower risk patients. For those purposes, the present study adds a hemodynamic 3-years follow-up. METHODS: A total of 77 patients underwent VIV-TAVR for failing aortic bioprosthesis during a 7-years period. Predominant mode of failure was stenosis in 87.0%. Patients had a mean age of 79.4 ± 5.8 years and a logistic EuroSCORE of 30.8 ± 15.7%. The Society of Thoracic Surgeons-PROM averaged 5.79 ± 2.63%. Clinical results and hemodynamic outcomes are reported for 30-days, 1-, 2-, and 3-years. Completeness of follow-up was 100% with 44 patients at risk after 3-years. Follow-up ranged up to 7.1 years. RESULTS: Majority of the surgical valves were stented (94.8%) with a mean labeled size of 23.1 ± 2.3 mm and true-ID of 20.4 ± 2.6 mm. A true-ID ≤21 mm had 58.4% of the patients. Self-expanding valves were implanted in 68.8% (mean labeled size 24.1 ± 1.8 mm) and balloon-expanded in 31.2% (mean size 24.1 ± 1.8 mm). No patient died intraoperatively. Hospital mortality was 1.3% and three-years survival 57.1%. All patients experienced an initial significant dPmean-reduction to 16.8 ± 7.1 mmHg. After 3-years mean dPmean raised to 26.0 ± 12.2 mmHg. This observation was independent from true-ID or type of transcatheter aortic valve replacement (TAVR)-prosthesis. Patients with a true-ID ≤21 mm had a higher initial (18.3 ± 5.3 vs. 14.9 ± 7.1 mmHg; p = .005) and dPmean after 1-year (29.2 ± 8.2 vs. 13.0 ± 6.7 mmHg; p = .004). There were no significant differences in survival. CONCLUSIONS: VIV-TAVR is safe and effective in the early period. In surgical valves with a true-ID ≤21 mm inferior hemodynamic and survival outcomes must be expected. Nonetheless, also patients with larger true-IDs showed steadily increasing transvalvular gradients. This raises concern about durability.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Estenosis de la Válvula Aórtica/etiología , Prótesis Valvulares Cardíacas/efectos adversos , Estudios de Seguimiento , Diseño de Prótesis , Hemodinámica , Resultado del Tratamiento
15.
Int J Mol Sci ; 23(19)2022 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-36232292

RESUMEN

Besides structural alterations in the myocardium, heart failure with preserved ejection fraction (HFpEF) is also associated with molecular and physiological alterations of the peripheral skeletal muscles (SKM) contributing to exercise intolerance often seen in HFpEF patients. Recently, the use of Sodium-Glucose-Transporter 2 inhibitors (SGLT2i) in clinical studies provided evidence for a significant reduction in the combined risk of cardiovascular death or hospitalization for HFpEF. The present study aimed to further elucidate the impact of Empagliflozin (Empa) on: (1) SKM function and metabolism and (2) mitochondrial function in an established HFpEF rat model. At the age of 24 weeks, obese ZSF1 rats were randomized either receiving standard care or Empa in the drinking water. ZSF1 lean animals served as healthy controls. After 8 weeks of treatment, echocardiography and SKM contractility were performed. Mitochondrial function was assessed in saponin skinned fibers and SKM tissue was snap frozen for molecular analyses. HFpEF was evident in the obese animals when compared to lean-increased E/é and preserved left ventricular ejection fraction. Empa treatment significantly improved E/é and resulted in improved SKM contractility with reduced intramuscular lipid content. Better mitochondrial function (mainly in complex IV) with only minor modulation of atrophy-related proteins was seen after Empa treatment. The results clearly documented a beneficial effect of Empa on SKM function in the present HFpEF model. These effects were accompanied by positive effects on mitochondrial function possibly modulating SKM function.


Asunto(s)
Agua Potable , Insuficiencia Cardíaca , Saponinas , Animales , Compuestos de Bencidrilo , Modelos Animales de Enfermedad , Glucosa/metabolismo , Glucósidos , Insuficiencia Cardíaca/metabolismo , Lípidos/farmacología , Músculo Esquelético/metabolismo , Obesidad/metabolismo , Ratas , Saponinas/farmacología , Sodio/metabolismo , Volumen Sistólico/fisiología , Función Ventricular Izquierda
16.
Lancet ; 396(10261): 1504-1510, 2020 11 07.
Artículo en Inglés | MEDLINE | ID: mdl-33091360

RESUMEN

BACKGROUND: In the treatment of de-novo coronary small vessel disease, drug-coated balloons (DCBs) are non-inferior to drug-eluting stents (DESs) regarding clinical outcome up to 12 months, but data beyond 1 year is sparse. We aimed to test the long-term efficacy and safety of DCBs regarding clinical endpoints in an all-comer population undergoing percutaneous coronary intervention. METHODS: In this prespecified long-term follow-up of a multicentre, randomised, open-label, non-inferiority trial, patients from 14 clinical sites in Germany, Switzerland, and Austria with de-novo lesions in coronary vessels <3 mm and an indication for percutaneous coronary intervention were randomly assigned 1:1 to DCB or second-generation DES and followed over 3 years for major adverse cardiac events (ie, cardiac death, non-fatal myocardial infarction, and target-vessel revascularisation [TVR]), all-cause death, probable or definite stent thrombosis, and major bleeding (Bleeding Academic Research Consortium bleeding type 3-5). Analyses were performed on the full analysis set according to the modified intention-to-treat principle. Dual antiplatelet therapy was recommended for 1 month after DCB and 6 months after DES with stable symptoms, but 12 months with acute coronary syndromes. The study is registered with ClinicalTrials.gov, NCT01574534 and is ongoing. FINDINGS: Between April 10, 2012, and Feb 1, 2017, of 883 patients assessed, 758 (86%) patients were randomly assigned to the DCB group (n=382) or the DES group (n=376). The Kaplan-Meier estimate of the rate of major adverse cardiac events was 15% in both the DCB and DES groups (hazard ratio [HR] 0·99, 95% CI 0·68-1·45; p=0·95). The two groups were also very similar concerning the single components of adverse cardiac events: cardiac death (Kaplan-Meier estimate 5% vs 4%, HR 1·29, 95% CI 0·63-2·66; p=0·49), non-fatal myocardial infarction (both Kaplan-Meier estimate 6%, HR 0·82, 95% CI 0·45-1·51; p=0·52), and TVR (both Kaplan-Meier estimate 9%, HR 0·95, 95% CI 0·58-1·56; p=0·83). Rates of all-cause death were very similar in DCB versus DES patients (both Kaplan-Meier estimate 8%, HR 1·05, 95% CI 0·62-1·77; p=0·87). Rates of probable or definite stent thrombosis (Kaplan-Meier estimate 1% vs 2%; HR 0·33, 95% CI 0·07-1·64; p=0·18) and major bleeding (Kaplan-Meier estimate 2% vs 4%, HR 0·43, 95% CI 0·17-1·13; p=0·088) were numerically lower in DCB versus DES, however without reaching significance. INTERPRETATION: There is maintained efficacy and safety of DCB versus DES in the treatment of de-novo coronary small vessel disease up to 3 years. FUNDING: Swiss National Science Foundation, Basel Cardiovascular Research Foundation, and B Braun Medical.


Asunto(s)
Angioplastia Coronaria con Balón/normas , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos/normas , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Enfermedades Cardiovasculares/etiología , Enfermedades Cardiovasculares/mortalidad , Enfermedad de la Arteria Coronaria/mortalidad , Stents Liberadores de Fármacos/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Resultado del Tratamiento
17.
Circulation ; 139(4): 448-457, 2019 01 22.
Artículo en Inglés | MEDLINE | ID: mdl-30026282

RESUMEN

BACKGROUND: Experimental trials suggest improved outcome by mild therapeutic hypothermia for cardiogenic shock after acute myocardial infarction. The objective of this study was to investigate the hemodynamic effects of mild therapeutic hypothermia in patients with cardiogenic shock complicating acute myocardial infarction. METHODS: Patients (n=40) with cardiogenic shock undergoing primary percutaneous coronary intervention without classic indications for mild therapeutic hypothermia underwent randomization in a 1:1 fashion to mild therapeutic hypothermia for 24 hours or control. The primary end point was cardiac power index at 24 hours; secondary end points included other hemodynamic parameters and serial measurements of arterial lactate. RESULTS: No relevant differences were observed for the primary end point of cardiac power index at 24 hours (mild therapeutic hypothermia versus control: 0.41 [interquartile range, 0.31-0.52] versus 0.36 [interquartile range, 0.31-0.48] W/m2; P=0.50; median difference, -0.025 W/m2; 95% CI, -0.12 to 0.06). Similarly, all other hemodynamic measurements were not statistically different. Arterial lactate levels at 6, 8, and 10 hours were significantly higher in patients in the mild therapeutic hypothermia group with a slower decline ( P for interaction=0.03). There were no differences in 30-day mortality (60% versus 50%; hazard ratio, 1.27; 95% CI, 0.55-2.94; P=0.55). CONCLUSIONS: In this randomized trial, mild therapeutic hypothermia failed to show a substantial beneficial effect on cardiac power index at 24 hours in patients with cardiogenic shock after acute myocardial infarction. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT01890317.


Asunto(s)
Hipotermia Inducida/métodos , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea , Choque Cardiogénico/terapia , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Femenino , Alemania , Hemodinámica , Humanos , Hipotermia Inducida/efectos adversos , Hipotermia Inducida/mortalidad , Ácido Láctico/sangre , Masculino , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/mortalidad , Infarto del Miocardio/fisiopatología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Recuperación de la Función , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/mortalidad , Choque Cardiogénico/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
18.
Catheter Cardiovasc Interv ; 96(2): E196-E203, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31714684

RESUMEN

OBJECTIVES: To evaluate the impact of previous coronary artery bypass grafting (CABG) on early safety at 30 days and 1-year mortality in patients receiving transcatheter aortic valve replacement (TAVR). BACKGROUND: The use of TAVR in patients with previous CABG suffering from severe aortic stenosis has increased in the last years. METHODS: Consecutive TAVR patients were stratified according to previous CABG versus no previous cardiac surgery (control). All-cause 1-year mortality and early safety at 30 days were evaluated. RESULTS: In the unmatched cohort and compared to control (n = 2,364), CABG (n = 260) were younger, more often male and suffered more often from comorbidities leading to an increased STS-score (p < .001). The rate of early safety events at 30 days was comparable between CABG and control (21.2% vs. 24.6%, p = .22) with a higher mortality in CABG (9.6% vs. 5.3%, p = .005). All-cause 1-year mortality was higher in CABG compared to controls (HR 1.51 [95%-CI 1.15-1.97], p = .003). Applying Cox regression analysis, both 30-day (HR 1.57 [95%-CI 0.97-2.53], p = .067) and all-cause 1-year mortality (HR 1.24 [95%-CI 0.91-1.70], p = .174) were not significantly different between groups. After propensity-score matching, the rate of early safety events at 30 days was lower in CABG compared to controls (21.6% vs. 31.7%, p = .02). Thirty-day (9.1% vs. 7.7%, p = .596) and all-cause 1-year mortality (24.0% vs. 23.1%, p = .520, HR 1.14 [95%-CI 0.77-1.69], p = .520) were not different between groups. CONCLUSION: In patients receiving TAVR, previous CABG was not associated with an increase in periprocedural complications and all-cause 1-year mortality when adjusted for other comorbidities.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Calcinosis/cirugía , Cateterismo Periférico , Puente de Arteria Coronaria , Arteria Femoral , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Cateterismo Periférico/efectos adversos , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/mortalidad , Femenino , Humanos , Masculino , Punciones , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
19.
Curr Cardiol Rep ; 22(9): 96, 2020 07 10.
Artículo en Inglés | MEDLINE | ID: mdl-32651654

RESUMEN

PURPOSE OF REVIEW: Stroke remains a devastating complication of cardiovascular interventions. This review is going to discuss stroke rates and outcomes in different cardiovascular procedures with a highlight on the current evidence for the use of cerebral protection devices (CPD). RECENT FINDINGS: Depending on the quality of neurological assessment, stroke occurs in up to 9.1% after TAVI, 3.9% after mitral clipping, 3.1% in LAAO patients, 0.4% after PCIs, and 1.8% after catheter ablation. CPDs are available for routine use. They are easy to use in most anatomies, feasible, and safe. Data on clinical impact and stroke reduction from RCTs are still missing. Most evidence for the routine use of CPDs exists in TAVI patients, who are at the highest risk. The PROTECTED TAVI RCT will shed more light on the clinical impact of CPD-use in TAVI patients. In other cardiovascular procedures like mitral clipping, PCIs, and ablation, the current data do not support the routine use of CPDs in these patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica/cirugía , Humanos , Resultado del Tratamiento
20.
Lancet ; 392(10150): 849-856, 2018 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-30170854

RESUMEN

BACKGROUND: Drug-coated balloons (DCB) are a novel therapeutic strategy for small native coronary artery disease. However, their safety and efficacy is poorly defined in comparison with drug-eluting stents (DES). METHODS: BASKET-SMALL 2 was a multicentre, open-label, randomised non-inferiority trial. 758 patients with de-novo lesions (<3 mm in diameter) in coronary vessels and an indication for percutaneous coronary intervention were randomly allocated (1:1) to receive angioplasty with DCB versus implantation of a second-generation DES after successful predilatation via an interactive internet-based response system. Dual antiplatelet therapy was given according to current guidelines. The primary objective was to show non-inferiority of DCB versus DES regarding major adverse cardiac events (MACE; ie, cardiac death, non-fatal myocardial infarction, and target-vessel revascularisation) after 12 months. The non-inferiority margin was an absolute difference of 4% in MACE. This trial is registered with ClinicalTrials.gov, number NCT01574534. FINDINGS: Between April 10, 2012, and February 1, 2017, 382 patients were randomly assigned to the DCB group and 376 to DES group. Non-inferiority of DCB versus DES was shown because the 95% CI of the absolute difference in MACE in the per-protocol population was below the predefined margin (-3·83 to 3·93%, p=0·0217). After 12 months, the proportions of MACE were similar in both groups of the full-analysis population (MACE was 7·5% for the DCB group vs 7·3% for the DES group; hazard ratio [HR] 0·97 [95% CI 0·58-1·64], p=0·9180). There were five (1·3%) cardiac-related deaths in the DES group and 12 (3·1%) in the DCB group (full analysis population). Probable or definite stent thrombosis (three [0·8%] in the DCB group vs four [1·1%] in the DES group; HR 0·73 [0·16-3·26]) and major bleeding (four [1·1%] in the DCB group vs nine [2·4%] in the DES group; HR 0·45 [0·14-1·46]) were the most common adverse events. INTERPRETATION: In small native coronary artery disease, DCB was non-inferior to DES regarding MACE up to 12 months, with similar event rates for both treatment groups. FUNDING: Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, Basel Cardiovascular Research Foundation, and B Braun Medical AG.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Materiales Biocompatibles Revestidos/uso terapéutico , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA