Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Oral Implantol ; 47(6): 485-490, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-33270835

RESUMEN

Different types of internal implant-abutment connections, namely hexagon and conical, have been used for implant restoration. However, data regarding the benefits of these internal connections in terms of clinical outcomes are scarce. Accordingly, the aim of this study was to compare radiographic marginal bone loss (RMBL) and associated implant complications between implants with internal hexagon (IH) connections and those with internal conical (IC) connections. Forty-nine patients with 98 implants (2 per patient) placed in the posterior mandible were recruited. All implants were inserted in pairs into solid D2 bone according to a randomized sequence; the first patient received an IH connection implant on the mesial side, while the second patient received an IC connection implant on the mesial side. Each patient received 1 implant with an IH connection and 1 with an IC connection, placed side by side. Four months after placement, all implants were loaded with single screw-retained ceramic restorations with IH or IC connections. RMBL and complications, including implant/prosthesis failure, were recorded at the time of implant loading (baseline) and at 6, 12, and 36 months after loading. The results revealed no significant between-group differences in RMBL (P = .74), gingival bleeding on probing (P = .29), and complications (P = .32). Thus, the type of internal implant-abutment connection did not affect clinical outcomes, including RMBL and implant/prosthesis failure. Future studies should additionally evaluate long-term prosthesis-related complications, such as screw loosening and fracture, between the 2 types of internal connections.


Asunto(s)
Implantes Dentales , Mandíbula , Tornillos Óseos , Diseño de Implante Dental-Pilar , Humanos
2.
Polymers (Basel) ; 14(10)2022 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-35631989

RESUMEN

Three-dimensional printed surgical guides increase the precision of orthodontic mini-implant placement. The purpose of this research was to investigate the effects of disinfection and of two types of autoclave sterilization on the mechanical properties of 3D printed surgical guides obtained via the SLA (stereolithography) and DLP (digital light processing) printing methods. A total of 96 standard specimens (48 SLA and 48 DLP) were printed to analyze the tensile and flexural properties of the materials. A total of 80 surgical guide (40 SLA and 40 DLP) specimens from each printing method were classified into four groups: CG (control group); G1, disinfected with 4% Gigasept (Gigasept Instru AF; Schülke & Mayer Gmbh, Norderstedt, Germany); G2, autoclave-sterilized (121 °C); and G3, autoclave-sterilized (134 °C). Significant differences in the maximum compressive load were determined between the groups comprising the DLP-(p < 0.001) and the SLA- (p < 0.001) printed surgical guides. Groups G2 (p = 0.001) and G3 (p = 0.029) showed significant parameter modifications compared with the CG. Disinfection with 4% Gigasept (Gigasept Instru AF; Schülke & Mayer Gmbh, Norderstedt, Germany) is suitable both for SLA- and DLP-printed surgical guides. Heat sterilization at both 121 °C and 134 °C modified the mechanical properties of the surgical guides.

3.
Materials (Basel) ; 15(6)2022 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-35329602

RESUMEN

The purpose of this study was to evaluate the clinical outcome of feldspathic ceramic laminate veneers over a 7-year period using minimally invasive techniques, such as vertical preparation (without prosthetic finish line), or no preparation (no-prep). A total of 170 feldspathic ceramic veneers were cemented in the anterior region, including 70 maxillary and 100 mandibular veneers, after special conditioning of the teeth and restorations. The veneers were evaluated using the FDI World Dental Federation criteria evaluation kit after recalling all the patients between February and June 2021. In total, 14 feldspathic veneers failed and were replaced with lithium disilicate because of core fracture, and 10 cases of chipping occurred on the ceramic surface and were polished. The overall survival rate was 91.77% for up to 7 years of function, with a failure rate of 8.23%. In this retrospective survival analysis, the failures, including the fracture of veneers and dental hard tissue, occurred both in prep and no-prep teeth. No failures were observed in veneers with a maximum thickness of 0.5 mm compared to those with a maximum thickness of 1 mm, 1.5 mm, 2 mm, and 2.5 mm.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA