Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Circ J ; 88(7): 1187-1197, 2024 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-38763735

RESUMEN

BACKGROUND: Limited data are available regarding clinical outcomes after percutaneous left atrial appendage closure using WATCHMAN FLX (WM-FLX) and WATCHMAN-2.5 (WM2.5) devices in Asian patients. METHODS AND RESULTS: Data of 1,464 consecutive patients (WM-FLX, n=909; WM2.5, n=555) were extracted from a Japanese multicenter registry, and clinical data were compared between the 2 groups. No in-hospital deaths, periprocedural stroke, or device embolization occurred. Procedural success was significantly higher in the WM-FLX than WM2.5 group (95.8% vs. 91.9%; P=0.002) owing to the lower incidence of periprocedural pericardial effusion (0.55% vs. 1.8%; P=0.021). No significant differences in all-cause death, postprocedural stroke, and device-related thrombus were observed between the 2 groups. However, the cumulative bleeding rate at 1 year was substantially lower in the WM-FLX group (7.8% vs. 16.4%; P<0.001). Landmark analysis of bleeding events highlighted lower bleeding rates in the WM-FLX than WM2.5 group within the first 6 months (6.4% vs. 14.8%; P<0.001), with comparable bleeding rates over the 6- to 12-month period (1.5% vs. 3.2%, respectively; P=0.065). CONCLUSIONS: This study demonstrated higher early safety and lower 1-year bleeding rates in the WM-FLX than WM2.5 group. The lower bleeding events with WM-FLX are likely due to multiple factors other than purely difference in devices, such as postprocedural drug regimen.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Sistema de Registros , Humanos , Anciano , Apéndice Atrial/cirugía , Masculino , Femenino , Anciano de 80 o más Años , Fibrilación Atrial/cirugía , Japón , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento , Persona de Mediana Edad , Cierre del Apéndice Auricular Izquierdo
2.
Heart Vessels ; 39(8): 687-695, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38710808

RESUMEN

BACKGROUND: Severe aortic valve stenosis (AS) and atrial fibrillation (AF) are risk factors of hemodynamic instability in heart failure (HF) management due to low cardiac output, respectively. Therefore, the treatment of HF due to severe AS complicated with AF is anticipated to be difficult. Tolvaptan, a vasopressin V2 receptor inhibitor, is effective in controlling acute decompensated heart failure (ADHF) with hemodynamic stability. However, its clinical efficacy against ADHF caused by AS with AF remains to be determined. METHODS: Clinical information (from September 2014 to December 2017) of 59 patients diagnosed with ADHF due to severe AS (20 patients with AF; 39 patients with sinus rhythm [SR]) was obtained from the LOHAS registry. The registry collected data from seven hospitals and assessed the short-term effects of tolvaptan in patients hospitalized for ADHF with severe AS. We attempted to identify clinical differences from baseline up to 4 days, comparing patients with AF (AF group) versus those with SR (SR group). RESULTS: There were no significant differences between the groups in age (83.7 ± 4.5 vs. 85.8 ± 6.9 years, respectively; p = 0.11) and aortic valve area (0.60 [0.46-0.73] vs. 0.56 [0.37-0.70] cm2, respectively; p = 0.50). However, left atrial volume was larger (104 [85-126] vs. 87 [64-103] mL, respectively; p < 0.01), whereas stroke volume was lower (51.6 ± 14.8 vs. 59.0 ± 18.7 mL, respectively; p = 0.08) in the AF group versus the SR group. Body weight decreased daily from baseline up to day 4 in both groups (from 55.4 to 53.2 kg [p < 0.01] and from 53.5 to 51.0 kg [p < 0.01], respectively) without change in heart rate. Notably, the systolic blood pressure decreased slightly in the AF group after 2 days of treatment with tolvaptan. CONCLUSIONS: Short-term treatment with tolvaptan improved HF in patients hospitalized for severe AS, regardless of the presence of AF or SR. After achieving sufficient diuresis, a slight decrease in blood pressure was observed in the AF group, suggesting an appropriate timeframe for safe and effective use of tolvaptan.


Asunto(s)
Antagonistas de los Receptores de Hormonas Antidiuréticas , Estenosis de la Válvula Aórtica , Fibrilación Atrial , Insuficiencia Cardíaca , Sistema de Registros , Tolvaptán , Humanos , Tolvaptán/uso terapéutico , Masculino , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Femenino , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/tratamiento farmacológico , Estenosis de la Válvula Aórtica/diagnóstico , Antagonistas de los Receptores de Hormonas Antidiuréticas/uso terapéutico , Anciano de 80 o más Años , Resultado del Tratamiento , Índice de Severidad de la Enfermedad , Estudios Retrospectivos , Anciano , Enfermedad Aguda , Japón/epidemiología , Hemodinámica/efectos de los fármacos
3.
Gan To Kagaku Ryoho ; 50(13): 1653-1655, 2023 Dec.
Artículo en Japonés | MEDLINE | ID: mdl-38303372

RESUMEN

A male patient in his 80s underwent colonic stenting for obstructive sigmoid colon cancer with multiple liver metastases. With systemic chemotherapy for approximately 1 year, the liver metastasis disappeared, so laparoscopic sigmoid colectomy was performed for the primary lesion. No recurrence was observed for a while, although CT revealed liver metastasis in the liver S4, and radiofrequency ablation was performed. Radiation therapy was performed for the liver metastasis of liver S2 that subsequently appeared. After a recurrence-free period of approximately 2 years, a rapid regrowth of liver metastasis in liver S2 was observed. Thus, 4 years and 3 months after the initial diagnosis, lateral segmentectomy of the liver was performed. Five years have passed since the first visit, and he is alive without recurrence. The patient had obstructive colorectal cancer with unresectable liver metastasis, and as the obstruction was released by a colonic stent, systemic chemotherapy was prioritized. Hence, liver metastasis was controlled, and the primary lesion was resected. Furthermore, for the liver metastasis that appeared later, various loco-regional cancer therapies were provided to achieve a cancer-free state.


Asunto(s)
Neoplasias Hepáticas , Neoplasias del Colon Sigmoide , Humanos , Masculino , Neoplasias del Colon Sigmoide/cirugía , Neoplasias del Colon Sigmoide/tratamiento farmacológico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/tratamiento farmacológico , Colon Sigmoide/patología
5.
Eur Heart J Case Rep ; 8(3): ytae126, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38515512

RESUMEN

Background: There are a few case reports regarding transcatheter aortic valve implantation (TAVI) for deteriorated surgical homograft. Case summary: We present a case of severe structural valve deterioration (SVD) of homograft surgical aortic valve presenting severe aortic regurgitation in an 84-year-old man with decompensated heart failure. We performed TAVI in homograft valve using 23 mm SAPIEN3 Ultra RESILIA. The resulting grade of paravalvular regurgitation was trace, the post-operative effective orifice area (EOA) was 1.66 cm2 (index EOA: 1.19 cm2/m2), and device success was achieved. Discussion: Stented bioprosthetic valves are more commonly implanted than mechanical and stentless bioprosthetic valves. In the 1980s and the early 1990s, homografts became particularly popular as alternatives to stented valves. There are several reports of TAVI for homograft SVD, but the paravalvular leakage grade is worse than that of redo-surgical aortic valve replacement, although the mortality rate is lower. However, the valves used in these reports were from older valves such as SAPIEN XT or SAPIEN3. There are no reports using SAPIEN3 Ultra RESILIA with a significant reduction in paravalvular leak due to an external textured polyethylene terephthalate skirt extending 40% higher above the valve inflow than the classical SAPIEN3, which is now available. Transcatheter aortic valve implantation using SAPIEN3 Ultra RESILIA showed good therapeutic efficacy.

6.
Eur Heart J Case Rep ; 8(6): ytae265, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38845807

RESUMEN

Background: Several reports have shown that transcatheter aortic valves are comparable in durability to surgical aortic valves. However, early structural valve deterioration (SVD) is rarely reported to occur, especially in haemodialysis patients. Case summary: We present a case of rapidly progressive bioprosthetic aortic valve stenosis in a patient with end-stage renal disease secondary to diabetic nephropathy in an 83-year-old female admitted due to progressive dyspnoea and orthopnoea. A 23 mm sized SAPIEN3 bioprosthetic aortic valve showed normal function for the first year after transcatheter aortic valve implantation (TAVI), but then rapidly developed stenosis and required acute hospitalization for heart failure a year and a half after surgery. Emergent surgical aortic valve replacement with a 19 mm On-X valve (CryoLife, Kennesaw, GA, USA) was performed. Pathological examination of the explanted SAPIEN 3 valve demonstrated severely degenerated bioprosthetic pericardial leaflets with severe intrinsic and extrinsic nodular calcifications, which could limit the leaflet motion. Discussion: There is a lack of reports on the long-term procedural outcomes of TAVI in haemodialysis patients. The development of SVD in patients undergoing dialysis is multifactorial and has yet to be fully elucidated. In the presented case, the removed TAVI valve had severe extrinsic calcified nodules alongside a fibrin thrombus. Considering these pathological findings, antithrombotic therapy to prevent fibrin thrombus from adhering to the TAVI valve may be important to avoid early SVD.

7.
Eur Heart J Case Rep ; 8(7): ytae322, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39045528

RESUMEN

Background: Transcatheter edge-to-edge mitral valve repair is now available in many countries and has achieved favourable therapeutic outcomes. However, there have been no reported cases of clip opening while locked (COWL) during the acute phase using the MitraClip G4 system (Abbott, Abbott Park, IL, USA). Case summary: We present two cases of COWL occurring at different phases: one immediately after clip release and the other 2 days post-procedure. In both cases, the initial treatment involved the use of the XTW system. Subsequently, an additional XT system was deployed for the deterioration of mitral regurgitation caused by COWL, without any complications. Discussion: The MitraClip G4 system offers four size variations, providing a larger grasping area and increased flexibility for accessing complex lesions. Furthermore, the complication rate decreased with increasing operator experience and device generation. However, it has been reported that COWL can occur after the clip is deployed during TEER. Although the mechanism of COWL is unclear, the nature and mobility of the valve leaflets and the product specificity of the MitraClip may be involved.

8.
J Cardiol ; 83(1): 49-56, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37591338

RESUMEN

BACKGROUND: Early prediction of aorta-related events is important for determining subsequent treatment strategies in patients with acute aortic dissection. However, most studies evaluated long-term aortic growth rates by annual assessment. The purpose of our study was to determine whether the in-hospital growth rate of aortic volume was associated with aorta-related events. METHODS: We studied 116 patients with uncomplicated type B acute aortic dissection. We analyzed whether changes in aortic volume were associated with aorta-related events during a 5-year follow-up. According to the growth rate from admission to discharge, patients were divided into two groups: Increase >0 (aortic volume: n = 59, aortic diameter: n = 43) and Reduction ≤0 (aortic volume: n = 57, aortic diameter: n = 73) in maximum aortic diameter or aortic volume. The primary endpoint was the discriminative ability of the growth rate of aortic volume for aorta-related events. RESULTS: According to the evaluation of aortic volume changes, the Increase group had significantly higher aorta-related event rates than those in the Reduction group (49.2 % vs. 3.5 %, respectively; p < 0.001). Receiver operating characteristics analysis showed that the growth rate of aortic volume had a clearly useful discrimination, with an area under the curve of 0.84, whereas the discriminative ability of the growth rate of maximum aortic diameter was poor (area under the curve: 0.53). Multivariate analysis showed that the growth rate of aortic volume from admission to discharge was an independent predictor of aorta-related events (hazard ratio, 26.3; 95 % confidence interval, 2.04-286.49; p = 0.001). CONCLUSIONS: In-hospital evaluation of aortic volume was helpful to predict long-term aorta-related events in patients with uncomplicated type B acute aortic dissection.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Humanos , Pronóstico , Alta del Paciente , Enfermedad Aguda , Factores de Riesgo , Aorta , Estudios Retrospectivos , Resultado del Tratamiento
9.
Am J Cardiol ; 223: 156-164, 2024 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-38797196

RESUMEN

The hemodynamic performance of self-expandable valves (SEVs) is a preferable choice for small aortic annuli in transcatheter aortic valve replacement (TAVR). However, no data are, so far, available regarding the relation between the size of SEVs and clinical outcomes. This study aimed to evaluate the impact of prosthesis size on adverse events after TAVR using SEVs. We retrospectively analyzed 1,400 patients (23-mm SEV: 13.6%) who underwent TAVR using SEVs at 12 centers. The impact of SEV size on all-cause death and heart failure (HF) after TAVR was evaluated by multivariate Cox regression and propensity score (PS) matching analysis. During the follow-up period (median 511 days), 201 all-cause deaths and 87 HF rehospitalizations were observed. The incidence of all-cause death was comparable between small- (23-mm SEV) and larger-sized (26- or 29-mm SEV) (16.8% vs 13.9%, log-rank p = 0.29). The size of SEV was not associated with a higher incidence of all-cause death (hazard ratio [HR] 1.21, 95% confidence interval [CI] 0.79 to 1.86 in Cox regression; HR 1.31, 95% CI 0.77 to 2.23 in PS matching) and HF after TAVR (subdistribution HR 0.79, 95% CI 0.37 to 1.72 in Cox regression; subdistribution HR 1.00, 95% CI 0.44 to 2.30 in PS matching). The multivariate model including postprocedural prosthesis-patient mismatch showed consistent results. In conclusion, small SEVs had comparable midterm clinical outcomes to larger-sized SEVs, even if the prosthesis-patient mismatch was observed after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Causas de Muerte/tendencias , Estudios de Seguimiento , Insuficiencia Cardíaca , Incidencia , Complicaciones Posoperatorias/epidemiología , Puntaje de Propensión , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
10.
JACC Asia ; 4(1): 1-9, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38222261

RESUMEN

Transcatheter structural heart interventions have drastically evolved over the past 2 decades. However, most catheterization procedures require the deployment of devices in the body; therefore, the adhesion of thrombi to those devices is a major problem, resulting in the requirement of a period of postprocedural antithrombotic regimen. However, in recent years, bleeding associated with these antithrombotic therapies has also become a major concern, attracting the attention of investigators. This is complicated by the fact that patients at high thrombotic risk are also at high bleeding risk, making the issue of administrating antithrombotic therapy challenging. The objective of this review was to identify the important issues and summarize the current status of postoperative antithrombotic therapy and assessment of the bleeding risk following transcatheter structural heart interventions such as transcatheter aortic valve replacement, transcatheter edge-to-edge repair, and transcatheter left atrial appendage occlusion.

11.
JACC Asia ; 4(4): 306-319, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38660100

RESUMEN

Background: Few reports on pre-existing left bundle branch block (LBBB) in patients undergoing transcatheter aortic valve replacement (TAVR) are currently available. Further, no present studies compare patients with new onset LBBB with those with pre-existing LBBB. Objectives: This study aimed to investigate the association between pre-existing or new onset LBBB and clinical outcomes after TAVR. Methods: Using data from the Japanese multicenter registry, 5,996 patients who underwent TAVR between October 2013 and December 2019 were included. Patients were classified into 3 groups: no LBBB, pre-existing LBBB, and new onset LBBB. The 2-year clinical outcomes were compared between 3 groups using Cox proportional hazards models and propensity score analysis to adjust the differences in baseline characteristics. Results: Of 5,996 patients who underwent TAVR, 280 (4.6%) had pre-existing LBBB, while 1,658 (27.6%) experienced new onset LBBB. Compared with the no LBBB group, multivariable Cox regression analysis showed that pre-existing LBBB was associated not only with a higher 2-year all-cause (adjusted HR: 1.39; 95% CI: 1.06-1.82; P = 0.015) and cardiovascular (adjusted HR: 1.60; 95% CI: 1.04-2.48; P = 0.031) mortality, but also with higher all-cause (adjusted HR: 1.43, 95% CI: 1.07-1.91; P = 0.016) and cardiovascular (adjusted HR: 1.81, 95% CI:1.12-2.93; P = 0.014) mortality than the new onset LBBB group. Heart failure was the most common cause of cardiovascular death, with more heart failure deaths in the pre-existing LBBB group. Conclusions: Pre-existing LBBB was independently associated with poor clinical outcomes, reflecting an increased risk of cardiovascular mortality after TAVR. Patients with pre-existing LBBB should be carefully monitored.

12.
Circ Cardiovasc Interv ; 17(6): e013794, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38629311

RESUMEN

BACKGROUND: The extent of cardiac damage and its association with clinical outcomes in patients undergoing transcatheter edge-to-edge repair (TEER) for degenerative mitral regurgitation remains unclear. This study was aimed to investigate cardiac damage in patients with degenerative mitral regurgitation treated with TEER and its association with outcomes. METHODS: We analyzed patients with degenerative mitral regurgitation treated with TEER in the Optimized Catheter Valvular Intervention-Mitral registry, which is a prospective, multicenter observational data collection in Japan. The study subjects were classified according to the extent of cardiac damage at baseline: no extravalvular cardiac damage (stage 0), mild left ventricular or left atrial damage (stage 1), moderate left ventricular or left atrial damage (stage 2), or right heart damage (stage 3). Two-year mortality after TEER was compared using Kaplan-Meier analysis. RESULTS: Out of 579 study participants, 8 (1.4%) were classified as stage 0, 76 (13.1%) as stage 1, 319 (55.1%) as stage 2, and 176 (30.4%) as stage 3. Two-year survival was 100% in stage 0, 89.5% in stage 1, 78.9% in stage 2, and 75.3% in stage 3 (P=0.013). Compared with stage 0 to 1, stage 2 (hazard ratio, 3.34 [95% CI, 1.03-10.81]; P=0.044) and stage 3 (hazard ratio, 4.51 [95% CI, 1.37-14.85]; P=0.013) were associated with increased risk of 2-year mortality after TEER. Significant reductions in heart failure rehospitalization rate and New York Heart Association functional scale were observed following TEER (both, P<0.001), irrespective of the stage of cardiac damage. CONCLUSIONS: Advanced cardiac damage is associated with an increased risk of mortality in patients undergoing TEER for degenerative mitral regurgitation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: UMIN000023653.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Sistema de Registros , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Masculino , Femenino , Anciano , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Japón , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Resultado del Tratamiento , Factores de Tiempo , Estudios Prospectivos , Factores de Riesgo , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Medición de Riesgo , Recuperación de la Función , Lesiones Cardíacas/mortalidad , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Lesiones Cardíacas/diagnóstico por imagen
13.
JACC Asia ; 4(7): 536-544, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39101119

RESUMEN

Background: Navitor, an intra-annular self-expanding heart valve (IA-SEV), is the third transcatheter heart valve introduced in Japan (in April 2022) as the next generation of the Portico valve ahead of other Asian countries. Objectives: The purpose of this study was to assess the patient-prosthesis mismatch (PPM) after IA-SEV implantation in Asian patients. Methods: All clinical data were collected from the database of an ongoing prospective Japanese multicenter registry (OCEAN-TAVI [Optimised Catheter Valvular Intervention transcatheter aortic valve implantation]). The primary endpoint was the rate of no PPM; the secondary endpoint included the rate of in-hospital mortality and hemodynamics after IA-SEV implantation. Results: A total of 463 patients (median age 86; 69.7% female) were enrolled in the registry. The percentages of implanted valves sized 23 mm, 25 mm, 27 mm, and 29 mm were 26.1% (n = 121), 41.7% (n = 193), 22.9% (n = 106), and 9.3% (n = 43), respectively. The primary endpoint of no PPM was achieved in 91.7% of the entire cohort and in 87.3%, 94.2%, 91.4%, and 93.0% of each valve size. The rate of in-hospital mortality was 1.9%. Postprocedural mean pressure gradient was 8.3 ± 4.3 mm Hg. The overall rate of pacemaker implantation was 9.7%; the incidence of pacemaker rate tended to be reduced when dividing the first and second half of operator experiences (13.0% vs. 8.0%; P = 0.08). Conclusions: The initial results for the IA-SEV were excellent regarding hemodynamics and reduction of paravalvular leakage regardless of valve size. The IA-SEV is a useful transcatheter heart valve, especially for Asian patients with a high prevalence of small annulus.

14.
ESC Heart Fail ; 11(4): 2159-2171, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38607328

RESUMEN

AIMS: A considerable proportion of candidates for transcatheter aortic valve implantation (TAVI) have underlying heart failure (HF) with preserved ejection fraction (HFpEF), which can be challenging for diagnosis because significant valvular heart disease should be excluded before diagnosing HFpEF. This study investigated the long-term prognostic value of the pre-procedural H2FPEF score in patients with preserved ejection fraction (EF) undergoing TAVI. METHODS AND RESULTS: Patients who underwent TAVI between October 2013 and May 2017 were enrolled from the Optimized CathEter vAlvular iNtervention-Transcatheter Aortic Valve Implantation Japanese multicentre registry. After excluding 914 patients, 1674 patients with preserved EF ≥ 50% (median age: 85 years, 72% female) were selected for calculation of the H2FPEF score and were dichotomized into two groups: the low H2FPEF score [0-5 points; n = 1399 (83.6%)] group and the high H2FPEF score [6-9 points; n = 275 (16.4%)] group. Patients with high H2FPEF scores were associated with a higher prevalence of New York Heart Association Functional Class III/IV (59.3% vs. 43.7%, P < 0.001), diabetes (24.4% vs. 18.5%, P = 0.03), and paradoxical low-flow, low-gradient aortic stenosis (15.9% vs. 6.2%, P < 0.001). These patients showed worse prognoses than those with low H2FPEF scores regarding the cumulative 2 year all-cause mortality (26.3% vs. 15.5%, log-rank P < 0.001), cardiovascular mortality (10.5% vs. 5.4%, log-rank P < 0.001), HF hospitalization (16.2% vs. 6.7%, log-rank P < 0.001), and the composite endpoint of cardiovascular mortality and HF hospitalization (23.8% vs. 10.8%, log-rank P < 0.001). After adjustment for several confounders, the high H2FPEF scores were independently associated with increased risk for all-cause mortality [adjusted hazard ratio (HR), 1.48; 95% confidence interval (CI), 1.09-2.00; P = 0.011] and for the composite endpoint of cardiovascular mortality and HF hospitalization (adjusted HR, 1.95; 95% CI, 1.38-2.74; P < 0.001). Subgroup analysis confirmed the excess risk of high H2FPEF scores relative to low H2FPEF scores for the composite endpoint of cardiovascular mortality and HF hospitalization increased with a lower Society of Thoracic Surgeons (STS) score (STS score <8%: adjusted HR, 2.40; 95% CI, 1.50-3.85; P < 0.001; STS score ≥8%: adjusted HR, 1.34; 95% CI, 0.79-2.28; P = 0.28; Pinteraction = 0.030). CONCLUSIONS: The H2FPEF score is useful for predicting long-term adverse outcomes after TAVI, including all-cause mortality, cardiovascular mortality, and HF hospitalization for patients with preserved EF. More aggressive interventions targeting HFpEF in addition to the TAVI procedure might be relevant in patients with high H2FPEF scores, particularly in those with a lower surgical risk.


Asunto(s)
Estenosis de la Válvula Aórtica , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Masculino , Anciano de 80 o más Años , Pronóstico , Estenosis de la Válvula Aórtica/cirugía , Volumen Sistólico/fisiología , Estudios de Seguimiento , Factores de Tiempo , Sistema de Registros , Insuficiencia Cardíaca/epidemiología , Japón/epidemiología , Tasa de Supervivencia/tendencias , Estudios Retrospectivos , Factores de Riesgo , Anciano , Medición de Riesgo/métodos
15.
Int J Cardiol Heart Vasc ; 53: 101449, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39022741

RESUMEN

Background: Percutaneous left atrial appendage closure (LAAC) is an effective therapy to prevent thromboembolic events among patients with atrial fibrillation (AF). However, since the left atrial appendage (LAA) contributes to left atrial volume and serves as a buffer for increasing left atrial pressure, this procedure may impair left atrium (LA) compliance, enlarge LA, and deteriorate diastolic function. In this study, we sought to investigate the change in left atrial volume index (LAVI) following LAAC and its effect on prognosis. Methods and Results: We analyzed 225 patients from the OCEAN-LAAC registry, an ongoing, multicenter Japanese study. Comparing LAVI measurements at baseline and 6 months after LAAC, no significant increase was observed (55.0 [44.0, 70.0] ml/m2 vs. 55.0 [42.0, 75.6] ml/m2; P = 0.31). However, some patients underwent LAVI increase. Particularly, a smaller LAVI (odds ratio [OR]: 0.98 [95 % confidence interval (CI): 0.97-0.996]) and elevated tricuspid regurgitation pressure (TRPG) at baseline (OR: 1.04 [95 % CI: 1.00 - 1.08]) were significantly related to the increase in LAVI at 6-month follow-up. In addition, a 5 ml/m2 increase in LAVI was significantly associated with subsequent heart failure hospitalization (HFH) (hazard ratio: 3.37 [95 % CI: 1.18-9.65]). This association, however, was not observed in patients with lower baseline LAVI (≤55 ml/m2) but was only seen in those with a baseline LAVI over 55 ml/m2. Conclusion: Our study demonstrated an increase in LAVI after LAAC was related to smaller LAVI or elevated TRPG at baseline. The LAVI increase was significantly associated with subsequent HFH.

16.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38726714

RESUMEN

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Femenino , Masculino , Anciano de 80 o más Años , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Diseño de Prótesis , Hemodinámica , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Mortalidad Hospitalaria
17.
J Clin Med ; 13(3)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38337545

RESUMEN

Background: Transcatheter edge-to-edge mitral valve repair (TEER) has emerged as a viable approach to addressing substantial secondary mitral regurgitation. In the contemporary landscape where ultimate heart failure-specific therapies, such as cardiac replacement modalities, are available, prognosticating a high-risk cohort susceptible to early cardiac mortality post-TEER is pivotal for formulating an effective therapeutic regimen. Methods: Our study encompassed individuals with secondary mitral regurgitation and chronic heart failure enlisted in the multi-center (Optimized CathEter vAlvular iNtervention (OCEAN)-Mitral registry. We conducted an assessment of baseline variables associated with cardiac death within one year following TEER. Results: Amongst the 1517 patients (median age: 78 years, 899 males), 101 experienced cardiac mortality during the 1-year observation period after undergoing TEER. Notably, a history of heart failure-related admissions within the preceding year, utilization of intravenous inotropes, and elevated plasma B-type natriuretic peptide levels emerged as independent prognosticators for the primary outcome (p < 0.05 for all). Subsequently, we devised a novel risk-scoring system encompassing these variables, which significantly stratified the cumulative incidence of the 1-year primary outcome (16%, 8%, and 4%, p < 0.001). Conclusions: Our study culminated in the development of a new risk-scoring system aimed at predicting 1-year cardiac mortality post-TEER.

18.
J Soc Cardiovasc Angiogr Interv ; 1(3): 100043, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-39131961

RESUMEN

Background: Few studies have investigated the progression of baseline mild or less tricuspid regurgitation (TR) after transcatheter aortic valve replacement (TAVR). The aim of this study was to investigate the prevalence and predictors of late progression of baseline mild or less TR and the impact of late progression on outcomes after TAVR. Methods: We reviewed 1615 patients who had baseline mild or less TR and 1-year echocardiographic follow-up registered in the Optimized Catheter Valvular Intervention-Transcatheter Aortic Valve Implantation registry. We compared outcomes including 2-year all-cause mortality, cardiac mortality, and heart failure hospitalization between groups with and without progression of TR on 1-year transthoracic echocardiography (TTE) and investigated predictors of progression of TR after TAVR. Results: On 1-year TTE, TR worsened to a moderate or severe grade in 87 patients (5.4%). The group with TR progression had higher 2-year all-cause mortality, cardiac mortality, and heart failure hospitalization than the group without TR progression. The multivariable analysis showed that TR progression was significantly associated with all-cause mortality (hazard ratio, 4.08; 95% CI, 1.92-8.67; P < .001) and heart failure hospitalization (hazard ratio, 2.85; 95% CI, 1.64-4.93; P < .001). Independent predictors of TR progression included atrial fibrillation, transaortic mean pressure gradient <40 â€‹mm Hg on pre-TAVR TTE, and systolic pulmonary artery pressure ≥40 â€‹mm Hg. Conclusions: TR progression from mild or less to moderate or severe after TAVR was more likely observed in patients with low transaortic gradients, atrial fibrillation, or pulmonary hypertension. TR progression after TAVR was associated with increased all-cause mortality and heart failure hospitalization.

19.
Am Heart J Plus ; 10: 100047, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38560646

RESUMEN

Background: Although intraplaque hemorrhage (IPH) has been identified as a key feature of rupture-prone plaques, noninvasive imaging-based features for its detection in coronary artery have not been clearly established. The aim of this study was to investigate the relationship of the ratio between the signal intensities of coronary plaque and cardiac muscle (PMR) on non-contrast T1-weighted imaging (T1WI) in magnetic resonance with IPH in the directional coronary atherectomy (DCA) specimens. Methods: Fifteen lesions from 15 patients, who underwent DCA and T1WI, were prospectively enrolled. The snap-frozen samples obtained by DCA were used for immunohistochemical staining against a protein specific to erythrocyte membranes (glycophorin A) and macrophages. The percentage of glycophorin A and macrophages was graded using a scale from 0 to 4, with higher scores indicating higher percentages. Results: PMR showed a strong positive correlation with glycophorin A scores (ρ = 0.772, p < 0.001), whreas, there was a weak correlation between the PMR and macrophage scores (ρ = 0.626, p < 0.05). The receiver-operating characteristic curve analysis showed that the optimal PMR cutoff value for predicting glycophorin A scores ≥grade 2 (glycophorin A-positive area ≥5% of the plaque) was 1.2 (area under the curve; 0.91, 95% confidence interval; 0.73-1.00), and this PMR value had a sensitivity of 8/9 (89%), specificity of 6/6 (100%), positive predictive value of 8/8 (100%), and negative predictive value of 6/7 (86%). Conclusions: In patients with ischemic heart disease, a high PMR on T1WI is a predictor of coronary IPH as assessed by DCA specimens.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA