Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 489
Filtrar
Más filtros

Intervalo de año de publicación
1.
Lancet ; 403(10445): 2695-2708, 2024 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-38795719

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
2.
Eur Heart J ; 45(28): 2478-2492, 2024 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-38888906

RESUMEN

Ventricular septal defects are a rare complication after acute myocardial infarction with a mortality close to 100% if left untreated. However, even surgical or interventional closure is associated with a very high mortality and currently no randomized controlled trials are available addressing the optimal treatment strategy of this disease. This state-of-the-art review and clinical consensus statement will outline the diagnosis, hemodynamic consequences and treatment strategies of ventricular septal defects complicating acute myocardial infarction with a focus on current available evidence and a focus on major research questions to fill the gap in evidence.


Asunto(s)
Defectos del Tabique Interventricular , Infarto del Miocardio , Humanos , Consenso , Defectos del Tabique Interventricular/cirugía , Defectos del Tabique Interventricular/complicaciones , Defectos del Tabique Interventricular/terapia , Defectos del Tabique Interventricular/diagnóstico , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/métodos
3.
Am Heart J ; 275: 128-137, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38838970

RESUMEN

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, P = .33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 P = .46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, P = .04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, P = .02), reduced SVi (34.2 vs 38 mL/m2, P < .01) and transaortic flow rate (190.6 vs 211 mL/s, P < .01). At predischarge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, P < .01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, P = .03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs 44 IQR 35-59 in those without, P = .02)). No evidence of a significant impact of PPM on overall (P = .71) and CV (P = .70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, P = .03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, P < .001) and LVOT diameter (OR 0.79, 0.65-0.95, P = .01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.


Asunto(s)
Estenosis de la Válvula Aórtica , Ecocardiografía , Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Anciano de 80 o más Años , Prótesis Valvulares Cardíacas/efectos adversos , Ecocardiografía/métodos , Estenosis de la Válvula Aórtica/cirugía , Anciano , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Ajuste de Prótesis
4.
Catheter Cardiovasc Interv ; 104(2): 181-190, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38988147

RESUMEN

BACKGROUND: In the elderly people with unprotected left main distal bifurcation lesions (ULMD), percutaneous coronary intervention (PCI) is often selected as first choice treatment strategy because of perioperative high risk of coronary artery bypass graft surgery due to their large number of comorbidities. Also, some recent papers reported that geriatric nutritional risk index (GNRI) is also strongly associated with clinical outcomes after interventional procedures in elderly patients. OBJECTIVES: We assessed clinical outcomes after PCI for ULMD and the impact of GNRI in elderly patients. METHODS: We identified 669 non dialysis patients treated with current generation drug-eluting stent for ULMD from MITO registry. We divided the patients to the following 2 groups; elderly group (n = 240, age ≥75) and young group (n = 429, age <75). Additionally, we could calculate GNRI and divided elderly group into 2 group based on the median value of the GNRI. The primary endpoint was all-cause mortality. RESULTS: All-cause mortality was significantly higher in elderly group [adjusted hazard ratio (HR) 2.37; 95% confidence interval (CI), 1.40-4.02; p = 0.001]. All-cause mortality was significantly higher in low GNRI elderly group compared to other 2 groups (Adjusted HR of elderly with low GNRI: 3.56, 95%CI (1.77-7.14), p < 0.001). Cardiovascular mortality was comparable between two groups. TLR rate was significantly lower in elderly group (adjusted HR 0.57; 95% CI, 0.34-0.97; p = 0.035). CONCLUSIONS: The elderly had higher all-cause mortality after PCI for ULMD compared to young people. Especially, the elderly with low GNRI were extremely associated with poorer outcomes.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Evaluación Geriátrica , Intervención Coronaria Percutánea , Sistema de Registros , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Intervención Coronaria Percutánea/instrumentación , Anciano , Masculino , Femenino , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Factores de Riesgo , Resultado del Tratamiento , Medición de Riesgo , Factores de Edad , Factores de Tiempo , Anciano de 80 o más Años , Persona de Mediana Edad , Estado Nutricional , Estudios Retrospectivos , Japón
5.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37957842

RESUMEN

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Dilatación , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Diseño de Prótesis
6.
J Cardiothorac Vasc Anesth ; 38(4): 911-917, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38281824

RESUMEN

OBJECTIVES: Caval valve implantation (CAVI) represents a minimally invasive strategy for managing severe tricuspid regurgitation in high-risk patients unsuitable for surgical or transcatheter tricuspid valve implantation. This case series aimed to assess the anesthesia management challenges and outcomes associated with this procedure, seeking to generate insights that can inform and refine anesthesia protocols. DESIGN: A case series. SETTING: At a cardiac catheterization laboratory of a teaching hospital. PARTICIPANTS: Eight patients undergoing CAVI with the Tricvalve system INTERVENTIONS: The anesthetic protocol included preprocedural planning, fast-track general anesthesia, and postprocedural debriefing. Intraoperative management involved anesthesia depth monitoring, real-time guidance via transesophageal echocardiography, and hemodynamic stability maintenance. Postoperative analgesia involved preemptive intravenous paracetamol and morphine as needed. MEASUREMENTS AND MAIN RESULTS: No anesthesia-related or implantation-related complications were observed, with a mean procedure duration of 112 ± 44 minutes. The median hospital stay was 4 days, and only 1 patient required brief intensive care unit monitoring. Postoperative right shoulder pain was reported by half of the patients, and was managed with morphine bolus administration (average dose 4.75 ± 3.6 mg). All patients had the device correctly positioned, as confirmed by postoperative transthoracic echocardiograms. None of the patients required outpatient analgesic therapy upon discharge. CONCLUSIONS: The authors' study demonstrated the potential of TricValve implantation in effectively managing severe tricuspid regurgitation with no procedure-related complications and a 100% survival rate. A collaborative, interdisciplinary approach and targeted anesthesia management proved crucial for this success. Postoperative shoulder pain emerged as a frequent complication, whose pathogenesis is still not clear, and successfully was managed using targeted analgesic therapy.


Asunto(s)
Anestésicos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Tricúspide/cirugía , Dolor de Hombro , Anestesia General/métodos , Analgésicos , Derivados de la Morfina , Resultado del Tratamiento , Cateterismo Cardíaco/métodos
7.
Eur Heart J ; 44(15): 1331-1339, 2023 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-36883599

RESUMEN

AIMS: Paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI) is associated with increased morbidity and mortality. The effect of transcatheter interventions to treat PVR after the index TAVI was investigated. METHODS AND RESULTS: A registry of consecutive patients who underwent transcatheter intervention for ≥ moderate PVR after the index TAVI at 22 centers. The principal outcomes were residual aortic regurgitation (AR) and mortality at 1 year after PVR treatment. A total of 201 patients were identified: 87 (43%) underwent redo-TAVI, 79 (39%) plug closure, and 35 (18%) balloon valvuloplasty. Median TAVI-to-re-intervention time was 207 (35; 765) days. The failed valve was self-expanding in 129 (63.9%) patients. The most frequent devices utilized were a Sapien 3 valve for redo-TAVI (55, 64%), an AVP II as plug (33, 42%), and a True balloon for valvuloplasty (20, 56%). At 30 days, AR ≥ moderate persisted in 33 (17.4%) patients: 8 (9.9%) after redo-TAVI, 18 (25.9%) after plug, and 7 (21.9%) after valvuloplasty (P = 0.036). Overall mortality was 10 (5.0%) at 30 days and 29 (14.4%) at 1 year: 0, 8 (10.1%), and 2 (5.7%) at 30 days (P = 0.010) and 11 (12.6%), 14 (17.7%), and 4 (11.4%) at 1 year (P = 0.418), after redo-TAVI, plug, and valvuloplasty, respectively. Regardless of treatment strategy, patients in whom AR was reduced to ≤ mild had lower mortality at 1 year compared with those with AR persisting ≥ moderate [11 (8.0%) vs. 6 (21.4%); P = 0.007]. CONCLUSION: This study describes the efficacy of transcatheter treatments for PVR after TAVI. Patients in whom PVR was successfully reduced had better prognosis. The selection of patients and the optimal PVR treatment modality require further investigation.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Pronóstico , Resultado del Tratamiento , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía
8.
Am Heart J ; 255: 94-105, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36272451

RESUMEN

BACKGROUND: Several electrocardiogram (ECG) criteria have been proposed to predict the location of the culprit occlusion in specific subsets of patients presenting with ST-segment elevation myocardial infarction (STEMI). The aim of this study was to develop, through an independent validation of currently available criteria, a comprehensive and easy-to-use ECG algorithm, and to test its diagnostic performance in real-world clinical practice. METHODS: We analyzed ECG and angiographic data from 419 consecutive STEMI patients submitted to primary percutaneous coronary intervention over a one-year period, dividing the overall population into derivation (314 patients) and validation (105 patients) cohorts. In the derivation cohort, we tested >60 previously published ECG criteria, using the decision-tree analysis to develop the algorithm that would best predict the infarct-related artery (IRA) and its occlusion level. We further assessed the new algorithm diagnostic performance in the validation cohort. RESULTS: In the derivation cohort, the algorithm correctly predicted the IRA in 88% of cases and both the IRA and its occlusion level (proximal vs mid-distal) in 71% of cases. When applied to the validation cohort, the algorithm resulted in 88% and 67% diagnostic accuracies, respectively. In a real-world comparative test, the algorithm performed significantly better than expert physicians in identifying the site of the culprit occlusion (P = .026 vs best cardiologist and P < .001 vs best emergency medicine doctor). CONCLUSIONS: Derived from an extensive literature review, this comprehensive and easy-to-use ECG algorithm can accurately predict the IRA and its occlusion level in all-comers STEMI patients.


Asunto(s)
Oclusión Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Oclusión Coronaria/complicaciones , Oclusión Coronaria/diagnóstico , Angiografía Coronaria , Infarto del Miocardio/diagnóstico , Electrocardiografía/métodos , Infarto del Miocardio con Elevación del ST/diagnóstico
9.
Rev Cardiovasc Med ; 24(8): 221, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39076703

RESUMEN

Background: The DynamX Novolimus-Eluting Coronary Bioadaptor System ( DynamX ® Bioadaptor) has uncaging elements that disengage after the resorption of the polymer coating, aiming to restore vessel function in the treated segment and to avoid long-term adverse outcomes associated with the permanent caging of the coronary artery seen with conventional stenting. Methods: This prospective, multicenter, single-arm first-in-human study enrolled 50 patients in Belgium and Italy who were treated with the DynamX Bioadaptor. Eligible patients had de novo lesions in coronary arteries measuring between 2.5 and 3.5 mm in diameter and ≤ 24 mm in length. Clinical follow-up was performed up to 36 months. This analysis includes the intention-to-treat population and is based on data available. The preclinical studies include optical coherence tomography (OCT) analyses of 5 DynamX Bioadaptors implanted in 3 mini Yucatan pigs (at 3, 12 and 24 months), and assessment of smooth muscle cell gene expression profile in 8 pigs of which each was implanted with the DynamX Bioadaptor and the Xience drug-eluting stent. To assess the gene expression profile by quantitative real-time polymerase chain reaction, animals were sacrificed at 3, 6, 9 and 12 months. Results: Target lesion failure at 36 months was 8.7% (4/46), consisting of one clinically-driven target lesion revascularization and 3 cardiac deaths (all site-reported to be unrelated to the device or procedure). There were no additional target vessel revascularization and no definite or probable scaffold thrombosis. Preclinical data confirmed late lumen enlargement (from 7.02 ± 1.31 mm 2 at baseline to 8.46 ± 1.31 mm 2 at 24 months) and identified an increased expression of contractile genes around 9 months compared to a conventional drug-eluting stent. Conclusions: The DynamX Bioadaptor demonstrated very good 36-month clinical outcomes, highlighted by the absence of target-vessel myocardial infarction and definite or probable device thrombosis, and only one target lesion revascularization up to 36 months. These data are supported by preclinical studies that showed late lumen enlargement by OCT and an increased expression of contractile genes around 9 months compared to conventional drug-eluting stents, indicating faster vessel healing. Larger clinical studies are necessary to compare outcomes against contemporary drug-eluting stents. Clinical Trial Registration: https://clinicaltrials.gov/: NCT03429894.

10.
Catheter Cardiovasc Interv ; 102(3): 486-488, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37454283

RESUMEN

Intracoronary calcium embolization during percutaneous procedure is a very rare and unpredictable event, that  can lead to serious complications and even expert operators could face some technical issues to solve it. This case report presents a technique called "block and crack" used to manage iatrogenic intracoronary calcium embolization of left anterior descending coronary artery. The technique involves implanting a drug eluting stent (DES) to block the embolus against the vessel wall, followed by the use of lithotripsy balloon inflated inside the DES to crack the calcium and achieve a better stent expansion. This technique allowed to avoid further distal calcium embolization as well as to minimize residual stenosis degree after stent implantation.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Litotricia , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/terapia , Calcio , Angiografía Coronaria/métodos , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Litotricia/efectos adversos , Enfermedad Iatrogénica , Ultrasonografía Intervencional
11.
Catheter Cardiovasc Interv ; 102(6): 1132-1139, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37668083

RESUMEN

BACKGROUND: Limited data are available on transcatheter heart valves (THVs) durability in bicuspid aortic valve (BAV) stenosis. AIMS: To evaluate evaluating 4-year clinical and echocardiographic outcomes of patients with BAV undergoing transcatheter aortic valve implantation (TAVI). METHODS: The bicuSpid TAvi duraBILITY (STABILITY) registry is an Italian multicentre registry including all consecutive patients with BAV and severe aortic stenosis (AS), treated by means of TAVI between January 2011 and December 2017. Outcomes of interest were all-cause death at 4-year, over time changes in echocardiographic measurements, and THV durability according to the valve aortic research consortium (VARC)-3 update definitions. RESULTS: Study population included 109 patients (50% females; mean age 78 ± 7.5 years) with a mean Society of Thoracic Surgeons Predicted Risk of Mortality score of 5.1 ± 4.3%. Median follow-up (FU) duration was 4.1 years [interquartile range: 2.8-5.1]. The overall cumulative incidence of all-cause death by Kaplan-Meier estimates at 4 years was 32%. Compared to baseline, a significant decrease in transprosthetic mean gradient was obtained after TAVI (54 ± 16 vs. 10 ± 5 mmHg; p < 0.001), whereas a significant increase was observed at 4-year (13 ± 6.4 mmHg, p = 0.03). Cumulative incidence of hemodynamic valve dysfunction (HVD) was 4%. Six patients met HVD criteria: three moderate and three severe HVD. All three cases of severe HVD were clinically relevant (bioprosthetic valve failure [BVF]) with two patients receiving a reintervention (TAVI in TAVI), and one patient experiencing a valve-related death due to endocarditis. CONCLUSIONS: The STABILITY registry suggests that in patients with severe AS and BAV undergoing TAVI, postprocedural clinical benefits might last, over time, up to 4-year FU. The low rates of severe HVD and BVF may support the hypothesis of good THV durability also in BAV recipient.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Estenosis de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Anciano , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Constricción Patológica , Resultado del Tratamiento , Enfermedades de las Válvulas Cardíacas/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Sistema de Registros
12.
Catheter Cardiovasc Interv ; 102(6): 1020-1033, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37855169

RESUMEN

BACKGROUND: Diabetic patients are at higher risk of recurrent adverse events following percutaneous coronary intervention (PCI) than the nondiabetics. Despite the introduction of new generation drug-eluting stents, their efficacy in the diabetics is still limited. AIMS: To evaluate the efficacy of the Abluminus DES+ biodegradable polymer sirolimus-eluting stent in reducing neointimal hyperplasia in diabetic patients, compared to a durable polymer everolimus-eluting stent (DP-EES). METHODS: A total of 131 patients with diabetes and coronary artery disease were enrolled in six Italian centers and randomized in a 2:1 fashion to PCI with Abluminus DES+ or DP-EES: 85 were assigned to Abluminus DES+ and 46 to DP-EES. The primary endpoint was optimal coherence tomography (OCT)-derived neointimal volume at 9-12 months. Secondary endpoints included OCT-derived neointimal area, neointimal volume obstruction and adverse clinical events. RESULTS: The primary endpoint, neointimal volume, did not differ between Abluminus DES+ and DP-EES (29.11 ± 18.90 mm3 vs. 25.48 ± 17.04 mm3 , p = 0.40) at 9-12-month follow-up. This finding remained consistent after weighing for the sum of stents lengths (1.14 ± 0.68 mm3 vs. 0.99 ± 0.74 mm3 for Abluminus DES+ and DP-EES, respectively, p = 0.38). Similarly, other OCT-derived and clinical secondary endpoints did not significantly differ between the two groups. Rate of target lesion failure was high in both groups (21.2% for Abluminus DES+ and 19.6% for DP-EES). CONCLUSIONS: This preliminary study failed to demonstrate the superiority of the Abluminus DES+ over the DP-EES in diabetic patients in terms of neointimal proliferation.


Asunto(s)
Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Implantes Absorbibles , Everolimus/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Sirolimus/efectos adversos , Tomografía de Coherencia Óptica , Resultado del Tratamiento
13.
Catheter Cardiovasc Interv ; 102(2): 310-317, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37232290

RESUMEN

BACKGROUND: The relationship between high postprocedural mean gradient (ppMG) and clinical events following mitral valve transcatheter edge-to-edge repair (MV-TEER) in patients with degenerative mitral regurgitation (DMR) is still debated. AIM: The purpose of this study was to evaluate the effect of elevated ppMG after MV-TEER on clinical events in patients with DMR at 1-year follow-up. METHODS: The study included 371 patients with DMR treated with MV-TEER enrolled in the "Multi-center Italian Society of Interventional Cardiology (GISE) registry of trans-catheter treatment of mitral valve regurgitation" (GIOTTO) registry. Patients were stratified in tertiles according to ppMG. Primary endpoint was a composite of all-cause death and hospitalization due to heart failure at 1-year follow-up. RESULTS: Patients were stratified as follows: 187 with a ppMG ≤ 3 mmHg, 77 with a ppMG > 3/=4 mmHg, and 107 with a ppMG > 4 mmHg. Clinical follow-up was available in all subjects. At multivariate analysis, neither a ppMG > 4 mmHg nor a ppMG ≥ 5 mmHg were independently associated with the outcome. Notably, the risk of elevated residual MR (rMR > 2+) was significantly higher in patients belonging to the highest tertile of ppMG (p = 0.009). The association of ppMG > 4 mmHg and rMR ≥ 2+ was strongly and independently associated with adverse events (hazard ratio: 1.98; 95% confidence interval: [1.10-3.58]). CONCLUSIONS: In a real-world cohort of patients suffering DMR and treated with MV-TEER, isolated ppMG was not associated with the outcome at 1-year follow-up. A high proportion of patients showed both elevated ppMG and rMR and their combination appeared to be a strong predictor of adverse events.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
14.
Catheter Cardiovasc Interv ; 102(1): 145-154, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37178388

RESUMEN

BACKGROUND: Mitral valve transcatheter edge-to-edge repair (M-TEER) is an effective option for treatment of mitral regurgitation (MR). We previously reported favorable 2-year outcomes for the PASCAL transcatheter valve repair system. OBJECTIVES: We report 3-year outcomes from the multinational, prospective, single-arm CLASP study with analysis by functional MR (FMR) and degenerative MR (DMR). METHODS: Patients with core-lab determined MR ≥ 3+ were deemed candidates for M-TEER by the local heart team. Major adverse events were assessed by an independent clinical events committee to 1 year and by sites thereafter. Echocardiographic outcomes were evaluated by the core laboratory to 3 years. RESULTS: The study enrolled 124 patients, 69% FMR; 31% DMR (60% NYHA class III-IVa, 100% MR ≥ 3+). The 3-year Kaplan-Meier estimate for survival was 75% (66% FMR; 92% DMR) and freedom from heart failure hospitalization (HFH) was 73% (64% FMR; 91% DMR), with 85% reduction in annualized HFH rate (81% FMR; 96% DMR) (p < 0.001). MR ≤ 2+ was achieved and maintained in 93% of patients (93% FMR; 94% DMR) and MR ≤ 1+ in 70% of patients (71% FMR; 67% DMR) (p < 0.001). The mean left ventricular end-diastolic volume (181 mL at baseline) decreased progressively by 28 mL [p < 0.001]. NYHA class I/II was achieved in 89% of patients (p < 0.001). CONCLUSIONS: The 3-year results from the CLASP study demonstrated favorable and durable outcomes with the PASCAL transcatheter valve repair system in patients with clinically significant MR. These results add to the growing body of evidence establishing the PASCAL system as a valuable therapy for patients with significant symptomatic MR.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estudios Prospectivos , Resultado del Tratamiento
15.
J Clin Ultrasound ; 51(4): 613-621, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36544331

RESUMEN

INTRODUCTION: Cardiac injury is commonly reported in COVID-19 patients, resulting associated to pre-existing cardiovascular disease, disease severity, and unfavorable outcome. Aim is to report cardiac magnetic resonance (CMR) findings in patients with myocarditis-like syndrome during the acute phase of SARS-CoV-2 infection (AMCovS) and post-acute phase (cPACS). METHODS: Between September 2020 and January 2022, 39 consecutive patients (24 males, 58%) were referred to our department to perform a CMR for the suspicion of myocarditis related to AMCovS (n = 17) and cPACS (n = 22) at multimodality evaluation (clinical, laboratory, ECG, and echocardiography). CMR was performed for the assessment of volume, function, edema and fibrosis with standard sequences and mapping techniques. CMR diagnosis and the extension and amount of CMR alterations were recorded. RESULTS: Patients with suspected myocarditis in acute and post-COVID settings were mainly men (10 (59%) and 12 (54.5%), respectively) with older age in AMCovS (58 [48-64]) compared to cPACS (38 [26-53]). Myocarditis was confirmed by CMR in most of cases: 53% of AMCovS and 50% of cPACS with negligible LGE burden (3 [IQR, 1-5] % and 2 [IQR, 1-4] %, respectively). Myocardial infarction was identified in 4/17 (24%) patients with AMCovS. Cardiomyopathies were identified in 12% (3/17) and 27% (6/22) of patients with AMCovS and cPACS, including DCM, HCM and mitral valve prolapse. CONCLUSIONS: In patients with acute and post-acute COVID-19 related suspected myocarditis, CMR improves diagnostic accuracy characterizing ischemic and non-ischemic injury and unraveling subclinical cardiomyopathies.


Asunto(s)
COVID-19 , Cardiomiopatías , Miocarditis , Masculino , Humanos , Femenino , Miocarditis/complicaciones , Miocarditis/diagnóstico por imagen , COVID-19/complicaciones , Valor Predictivo de las Pruebas , SARS-CoV-2 , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Medios de Contraste
16.
Circulation ; 143(2): 104-116, 2021 01 12.
Artículo en Inglés | MEDLINE | ID: mdl-32975133

RESUMEN

BACKGROUND: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. METHODS: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. RESULTS: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76-996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510-1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR (P<0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients (P=0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P<0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P=0.02). The rates of Mitral Valve Academic Research Consortium-defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P=0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74-12.56; P=0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88-21.53; P<0.001) were both independently associated with repeat mitral valve replacement. CONCLUSIONS: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas/normas , Válvula Mitral/cirugía , Sistema de Registros , Reoperación/normas , Reemplazo de la Válvula Aórtica Transcatéter/normas , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Prótesis Valvulares Cardíacas/tendencias , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Humanos , Internacionalidad , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Reoperación/tendencias , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/tendencias
17.
Radiology ; 302(3): 545-553, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34874200

RESUMEN

Background Acute chest pain with mild troponin rise and inconclusive diagnosis after clinical evaluation represents a diagnostic challenge. Triple-rule-out (TRO) CT may exclude coronary artery disease (CAD), as well as acute aortic syndrome and pulmonary embolism, but cannot help identify other causes of myocardial injury. Purpose To investigate the diagnostic value of a comprehensive CT protocol including both an angiographic and a late contrast enhancement (LCE) scan in participants with troponin-positive acute chest pain. Materials and Methods In this prospective study, consecutive patients with troponin-positive acute chest pain or anginal equivalent and inconclusive diagnosis after clinical evaluation (symptoms, markers, electrocardiography, and echocardiography) who underwent TRO CT between June 2018 and September 2020 were enrolled. TRO CT was performed to evaluate the presence of obstructive CAD (stenosis ≥50%), acute aortic syndrome, and pulmonary embolism. If the findings on the TRO CT scan were negative, an LCE CT scan was acquired after 10 minutes to assess the presence and pattern of scar and quantify the myocardial extracellular volume fraction. CT-based diagnoses were compared with diagnoses obtained with reference standard methods, including invasive coronary angiography, cardiac MRI, and endomyocardial biopsy. Results Eighty-four patients (median age, 69 years [interquartile range, 50-77 years]; 45 men) were enrolled. TRO CT helped identify obstructive CAD in 35 participants (42%), acute aortic syndrome in one (1.2%), and pulmonary embolism in six (7.1%). LCE CT scans were acquired in the remaining 42 participants. The following diagnoses were reached with use of LCE CT: myocarditis (22 of 42 participants [52%]), takotsubo cardiomyopathy (four of 42 [10%]), amyloidosis (three of 42 [7.1%]), myocardial infarction with nonobstructed coronary arteries (three of 42 [7.1%]), dilated cardiomyopathy (two of 42 [4.8%]), and negative or inconclusive findings (eight of 42 [19%]). The addition of LCE CT improved the diagnostic rate of TRO CT from 42 of 84 participants (50% [95% CI: 38.9, 61.1]) to 76 of 84 (90% [95% CI: 82.1, 95.8]) (P < .001). Conclusion A CT protocol including triple-rule-out and late contrast enhancement CT scans improved diagnostic rate in participants presenting with acute chest pain syndrome. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Nagpal and Bluemke in this issue.


Asunto(s)
Dolor en el Pecho/diagnóstico por imagen , Dolor en el Pecho/etiología , Tomografía Computarizada por Rayos X/métodos , Troponina/sangre , Enfermedad Aguda , Anciano , Biomarcadores/sangre , Medios de Contraste , Angiografía Coronaria , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Síndrome
18.
J Vasc Surg ; 75(3): 868-876.e3, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34600031

RESUMEN

BACKGROUND: The aim of the study was to demonstrate the safety and effectiveness of a suture-mediated vascular closure device to perform hemostasis after an axillary artery access during endovascular procedures on the aortic valve, the aorta and its side branches. METHODS: A physician-initiated, international, multicenter, retrospective registry was designed to evaluate the success rate (VARC-2 reporting standards) of percutaneous transaxillary access closure with a suture-mediated closure device. Secondary end points were minor access vascular complications, transient peripheral nerve injury, stroke, and influence on periprocedural outcomes of puncture technique. RESULTS: Three hundred thirty-one patients (median age, 76 years; 69.2% males) in 11 centers received a percutaneous transaxillary access during endovascular cardiac (n = 166) or vascular (n = 165) procedures. The closure success rate was 84.6%, with 5 open conversions (1.5%), 45 adjunctive endovascular procedures (13.6%), and 1 nerve injury (0.3%). Secondary closure success was obtained in 325 patients (98%) after 7 bare stenting, 37 covered stenting, and 1 thrombin injection. Introducer sheaths 16F or larger (odds ratio, 3.70; 95% confidence interval, 1.22-11.42) and balloon-assisted hemostasis (odds ratio, 4.45; 95% confidence interval, 1.27-15.68) were associated with closure failure. A threshold of five percutaneous axillary accesses was associated with decreased rates of open conversion, but not with increased primary closure success. Primary closure success was 90.3% in the 175 patients with sheaths smaller than 16F, performed after the first 5 procedures in each center. Temporary nerve injury and stroke were observed in 2% and 4% of patients, respectively. CONCLUSIONS: Percutaneous transaxillary aortic procedures, in selected patients, can be performed with low rates of open conversion. The need for additional endovascular bailout procedures is not negligible when introducers sheaths 16F or larger are required.


Asunto(s)
Aorta Torácica/cirugía , Enfermedades de la Aorta/cirugía , Válvula Aórtica/cirugía , Arteria Axilar , Implantación de Prótesis Vascular , Cateterismo Periférico , Procedimientos Endovasculares , Enfermedades de las Válvulas Cardíacas/cirugía , Anciano , Anciano de 80 o más Años , Aorta Torácica/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Cateterismo Periférico/efectos adversos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Europa (Continente) , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Punciones , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
19.
Eur J Clin Invest ; 52(1): e13658, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34310688

RESUMEN

BACKGROUND: Limited clinical data exist describing the use of direct oral anticoagulants (DOACs) in patient with extreme body weight. Thus, the International Society of Thrombosis and Haemostasis (ISTH) recommends avoiding DOACs in patients with weight >120 Kg, and on the contrary, no restrictions exist for underweight patients. OBJECTIVE: To evaluate the effects of extreme body weight on DOAC activity and to compare the clinical outcomes of patients with an extreme body weight versus patients with a normal weight (61-119 Kg) treated with DOACs. METHODS: Single tertiary care Italian centre multidisciplinary registry including nonvalvular atrial fibrillation (NVAF) patients treated with DOACs. Based on weight, three subcohorts were defined: (i) underweight patients (≤60 Kg); (ii) patients with a normal weight (61-119 Kg, as control group); and (iii) overweight patients (≥120 Kg). Primary efficacy endpoint was 2-year rate of thromboembolic events. Primary safety endpoint was 2-year rate of major bleeding. Event-free survival curves among groups were compared using Cox-Mantel test. RESULTS: 812 NVAF patients were included, 108 patients weighed ≤60 Kg (13%, underweight), 688 weighed between 61 and 119 Kg (85%, normal weight), and 16 weighed ≥120 Kg (2%, overweight). In particular, among underweight patients, dabigatran was prescribed in 26% patients, apixaban in 27%, rivaroxaban in 28% and edoxaban in 22% ones. Instead, among overweight patients, 44% were treated with dabigatran, 25% with apixaban, 25% with rivaroxaban and 4% with edoxaban. Underweight patients were older, more frequently women, with lower creatinine clearance and a history of previous strokes, resulting in higher CHA2DS2-VASc score than in both remaining groups. Up to 2 years, no statistically significant difference was observed between the three groups of weight for thromboembolic events (P = .765) and for overall bleeding (P = .125), but a trend towards decreased overall bleeding rates was noticed as weight increased (24.1% vs 16.7% vs 12.5%, respectively). CONCLUSION: In this tertiary care centre registry, 15% of patients treated with DOACs presented an extreme weight. Compared to patients with a normal weight, no significant rates of thromboembolic events were observed for underweight or overweight patients. A trend towards decreased overall bleeding frequency as weight increased was highlighted up to 2 years. The present results should be considered as preliminary and hypothesis generating.


Asunto(s)
Anticoagulantes/administración & dosificación , Peso Corporal , Tromboembolia/prevención & control , Administración Oral , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tromboembolia/etiología
20.
Catheter Cardiovasc Interv ; 100(2): 190-198, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35686523

RESUMEN

AIM: The impact of Grade III coronary perforations (G3-CP) in the setting of CTO-PCI is not well assessed. METHODS AND RESULTS: We reviewed 7773 CTO-PCI and 98,819 non CTO-PCI performed in 10 European centers: G3 perforation occurred in 87 patients (1.1%) during CTO PCI and 224 patients (0.22%) during non CTO-PCI (p < 0.001). G3-CP involved the CTO segment in 68% of patients and the retrograde channels in 14% of cases. In the CTO PCI group, wire induced G3-CP (50.5% vs. 32.5%, p = 0.02) occurred predominantly when dedicated CTO tapered and highly penetrative wires were used. Intra-procedural and in-hospital death rates were 4.6% vs. 5.8% and 3.6% vs. 7.5% respectively for CTO PCI and non-CTO PCI groups (p = NS). At a median follow up of 24 months, the overall mortality and MAE were respectively 7.8% and MAE 19% without difference among groups. CONCLUSIONS: We showed similar in-hospital and long-term outcomes when G3 perforations occurred during CTO PCI and non CTO-PCI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Oclusión Coronaria , Lesiones Cardíacas , Intervención Coronaria Percutánea , Lesiones del Sistema Vascular , Enfermedad Crónica , Angiografía Coronaria , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Mortalidad Hospitalaria , Humanos , Sistema de Registros , Factores de Riesgo , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA