1.
Materials (Basel) ; 16(18)2023 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-37763418

RESUMEN

Due to the expansion of the use of powder bed fusion metal additive technologies in the medical field, especially for the realization of dental prostheses, in this paper, the authors propose a comparative experimental study of the mechanical characteristics and the state of their microscale surfaces. The comparison was made from material considerations starting from two dental alloys commonly used to realize dental prostheses: Ni-Cr and Co-Cr, but also technologies for obtaining selective laser melting (SLM) and conventional casting. In addition, to compare the performances with the classical casting technology, for the dental prostheses obtained through SLM, the post-processing stage in which they are in a preliminary finishing and polished state was considered. Therefore, for the determination of important mechanical characteristics and the comparative study of dental prostheses, the indentation test was used, after which the hardness, penetration depths (maximum, permanent, and contact depth), contact stiffness, and contact surface were established, and for the determination of the microtopography of the surfaces, atomic force microscopy (AFM) was used, obtaining the local areal roughness parameters at the miniaturized scale-surface average roughness, root-mean-square roughness (RMS), and peak-to-peak values. Following the research carried out, several interesting conclusions were drawn, and the superiority of the SLM technology over the classic casting method for the production of dental prostheses in terms of some mechanical properties was highlighted. At the same time, the degree of finishing of dental prostheses made by SLM has a significant impact on the mechanical characteristics and especially the local roughness parameters on a miniaturized scale, and if we consider the same degree of finishing, no major differences are observed in the roughness parameters of the surfaces of the prostheses produced by different technologies.

2.
Children (Basel) ; 9(1)2022 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-35053732

RESUMEN

BACKGROUND: The arches used in orthodontic therapy are subject to increasing physical and chemical stresses. PURPOSE OF THE STUDY: This in vitro experimental study aims to highlight and compare the main mechanical properties of orthodontic arches. MATERIALS AND METHODS: We used 40 springs, 2 materials, 20 of Ni-Cr and 20 of Co-Cr, of different diameters, 0.7 mm 0.8 mm and 1.2 mm, subjected to the environment of artificial saliva and artificial saliva with cola for one month and two months, respectively. Five springs of each material were tested at different times: T0, before application in the oral cavity, then at time T1, T2, T3, T4. Three lengths of the lever arm were considered for bending forces acting on the springs (dental wires). These lengths were 15, 10 and 5 mm. The wires were tested under the action of bending forces on a Hans Schmidt HV 500N stand, obtaining the characteristics of the wires: deformation-force-time. RESULTS: Graphical determinations show that the degree of deformation of the wires is influenced by the applied force, diameter and obviously by the immersion time, respectively by the type of solution in which the springs were immersed. CONCLUSIONS: The final degree of bending is higher for Co-Cr arcs than for Ni-Cr at all three dimensions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA