RESUMEN
OBJECTIVE: The aim of this study was to verify the association among obstructive sleep apnea, functional capacity, and metabolic control. METHODS: This was a cross-sectional study involving individuals of both sexes with clinical diagnosis of diabetes mellitus type 2 who were above 18 years of age. The assessment consisted of a volunteer identification form, a 2-minute step test, and the Stop-Bang questionnaire. In order to assess metabolic control, HbA1c and fasting glucose data were collected from medical records. RESULTS: A total of 100 individuals with diabetes mellitus type 2, of whom 61% were women, were included in this study. According to the Stop-Bang instrument, 26, 57, and 17% of patients had low, intermediate, and high risk of developing OSA, respectively. There was no association between the 2-minute step test and metabolic variables and diabetes mellitus type 2 chronicity with Stop-Bang. CONCLUSIONS: We concluded that there is no association among obstructive sleep apnea measured by means of Stop-Bang instrument, functional capacity measured by means of 2-minute step test, and metabolic variables in individuals with diabetes mellitus type 2.
Asunto(s)
Diabetes Mellitus Tipo 2 , Apnea Obstructiva del Sueño , Estudios Transversales , Diabetes Mellitus Tipo 2/complicaciones , Femenino , Humanos , Masculino , Polisomnografía , Estudios Prospectivos , Apnea Obstructiva del Sueño/epidemiología , Encuestas y CuestionariosRESUMEN
SUMMARY OBJECTIVE: The aim of this study was to verify the association among obstructive sleep apnea, functional capacity, and metabolic control. METHODS: This was a cross-sectional study involving individuals of both sexes with clinical diagnosis of diabetes mellitus type 2 who were above 18 years of age. The assessment consisted of a volunteer identification form, a 2-minute step test, and the Stop-Bang questionnaire. In order to assess metabolic control, HbA1c and fasting glucose data were collected from medical records. RESULTS: A total of 100 individuals with diabetes mellitus type 2, of whom 61% were women, were included in this study. According to the Stop-Bang instrument, 26, 57, and 17% of patients had low, intermediate, and high risk of developing OSA, respectively. There was no association between the 2-minute step test and metabolic variables and diabetes mellitus type 2 chronicity with Stop-Bang. CONCLUSIONS: We concluded that there is no association among obstructive sleep apnea measured by means of Stop-Bang instrument, functional capacity measured by means of 2-minute step test, and metabolic variables in individuals with diabetes mellitus type 2.