Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Ig Sanita Pubbl ; 76(4): 241-255, 2020.
Artículo en Italiano | MEDLINE | ID: mdl-33161421

RESUMEN

The last few weeks of pregnancy are critical to a baby's health because important organs, including the brain and lungs, are not completely developed until the end of pregnancy. The adverse events during labor and childbirth can have very serious physical, psychological and financial consequences for the child, the family, health professionals and the whole community. These events can be reduced through interventions aimed at improving the safety and quality of care, based on evidence-based knowledge, guidelines and practices that must be widely and effectively applied. This work reports the experience of the Lombardy Region on improvement actions in the obstetric and gynecological procedures for the reduction of adverse events and sentinel events through the monitoring and management of the RCGS trigger tool.


Asunto(s)
Procedimientos Quirúrgicos Ginecológicos/normas , Seguridad del Paciente , Garantía de la Calidad de Atención de Salud/normas , Mejoramiento de la Calidad , Calidad de la Atención de Salud , Niño , Parto Obstétrico , Femenino , Humanos , Ciencia de la Implementación , Lactante , Guías de Práctica Clínica como Asunto , Embarazo
2.
Rev Sci Instrum ; 95(8)2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39158393

RESUMEN

Following successful campaigns on the compact high field spherical tokamak ST40, resistive gold foil bolometers have now been installed to measure the radiated power profile. Positioned on the midplane, two bolometer cameras offer perspectives of the horizontal and vertical planes, while the third camera, situated above the midplane, provides a vertical view of the top divertor plates, including the X-point and the strike points. These cameras use a commercial off-the-shelf data acquisition platform with modules specifically designed for bolometers in a Wheatstone bridge configuration, providing both phase sensitive detection and in situ calibration. This paper presents an overview of the design and functionality of all three cameras and the commissioning of the horizontal plane camera. The commissioning of the horizontal camera shows data from a range of plasma pulses, presenting a positive correlation between the relative profiles measured from the bolometer camera and an absolute extreme ultraviolet diode camera viewing along similar lines of sight.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA