Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Biomech Eng ; 143(4)2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33332544

RESUMEN

A validation comparing five human body model (HBM) lumbar spines is carried out across two load cases, with the objective to use and apply HBMs in high strain rate applications such as car occupant simulation. The first load case consists of an individual intervertebral disc (IVD) loaded in compression at a strain rate of 1/s by a material testing machine. The second load case is a lumbar functional spine unit (FSU) loaded in compression using a drop tower setup, producing strain rates of up to 48/s. The IVD simulations were found to have a better agreement with the experiments than the FSU simulations, and the ranking of which HBMs matched best to the experiment differed by load case. These observations suggest the need for more hierarchical validations of the lumbar spine for increasing the utility of HBMs in high strain rate loading scenarios.


Asunto(s)
Disco Intervertebral
2.
Surg Radiol Anat ; 39(3): 281-291, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27272933

RESUMEN

PURPOSE: Cadaveric studies have previously documented a typical pattern of venous drainage within vertebral bodies (VBs), comprised primarily of the basivertebral vein. These studies, however, are limited by the number of samples available. MRI is able to provide 3D images of soft tissue structures in the spine, including the basivertebral vein without the use of contrast in both healthy controls and subjects with abnormal anatomy such as adolescent idiopathic scoliosis (AIS). This study aimed to quantify the venous networks within VBs of 15 healthy adolescent controls and 15 AIS patients. METHODS: Five transverse slices through the VBs were examined simultaneously and the observable vascular network traced. The length of the network on the left and right sides of the VB was calculated, and the spatial patterning assessed level-by-level within each subject. RESULTS: Significant differences were seen in the left/right distribution of vessels in both the control and AIS subjects, with both groups having greater length on the right side of all of their VBs. No difference was seen between AIS and control subjects in any region. Large individual variations in patterns were seen in both groups; however, the control group showed more consistent spatial patterning of the vascular networks across levels in comparison to the AIS group. CONCLUSION: The length of the basivertebral vein was seen to have a significant bias to the right hand side of the VB in both healthy and AIS adolescents. The spatial pattern of this vein showed large variations in branching both within and across individuals. No significant differences were seen between AIS and control subjects, suggesting both that this network is preserved in deformed AIS vertebrae, and that the vertebral venous system does not play a role in the etiology of AIS.


Asunto(s)
Variación Anatómica , Vértebras Lumbares/irrigación sanguínea , Escoliosis/diagnóstico por imagen , Vértebras Torácicas/irrigación sanguínea , Venas/anatomía & histología , Adolescente , Niño , Humanos , Imagenología Tridimensional , Vértebras Lumbares/diagnóstico por imagen , Imagen por Resonancia Magnética , Vértebras Torácicas/diagnóstico por imagen , Venas/diagnóstico por imagen
3.
JOR Spine ; 7(2): e1332, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38655007

RESUMEN

Background: Nucleus replacement devices (NRDs) are not routinely used in clinic, predominantly due to the risk of device expulsion. Rigorous in vitro testing may enable failure mechanisms to be identified prior to clinical trials; however, current testing standards do not specify a particular expulsion test. Multiple methods have therefore been developed, complicating comparisons between NRD designs. Thus, this study assessed the effectiveness of four previously reported expulsion testing protocols; hula-hoop (Protocol 1), adapted hula-hoop (Protocol 2), eccentric cycling (Protocol 3), and ramp to failure (Protocol 4), applied to two NRDs, one preformed and one in situ curing. Methods: Nucleus material was removed from 40 bovine tail intervertebral disks. A NRD was inserted posteriorly into each cavity and the disks were subjected to one of four expulsion protocols. Results: NRD response was dependent on both the NRD design and the loading protocol. Protocol 1 resulted in higher migration and earlier failure rates compared to Protocol 2 in both NRDs. The preformed NRD was more likely to migrate when protocols incorporated rotation. The NRDs had equal migration (60%) and expulsion (60%) rates when using unilateral bending and ramp testing. Combining the results of multiple tests revealed complimentary information regarding the NRD response. Conclusions: Adapted hula-hoop (Protocol 2) and ramp to failure (Protocol 4), combined with fluoroscopic analysis, revealed complimentary insights regarding migration and failure risk. Therefore, when adopting the surgical approach and animal model used in this study, it is recommended that NRD performance be assessed using both a cyclic and ramp loading protocol.

4.
Biomech Model Mechanobiol ; 22(1): 123-132, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36121529

RESUMEN

Spinal fixation and fusion are surgical procedures undertaken to restore stability in the spine and restrict painful or degenerative motion. Malpositioning of pedicle screws during these procedures can result in major neurological and vascular damage. Patient-specific surgical guides offer clear benefits, reducing malposition rates by up to 25%. However, they suffer from long lead times and the manufacturing process is dependent on third-party specialists. The development of a standard set of surgical guides may eliminate the issues with the manufacturing process. To evaluate the feasibility of this option, a statistical shape model (SSM) was created and used to analyse the morphological variations of the T4-T6 vertebrae in a population of 90 specimens from the Visible Korean Human dataset (50 females and 40 males). The first three principal components, representing 39.7% of the variance within the population, were analysed. The model showed high variability in the transverse process (~ 4 mm) and spinous process (~ 4 mm) and relatively low variation (< 1 mm) in the vertebral lamina. For a Korean population, a standardised set of surgical guides would likely need to align with the lamina where the variance in the population is lower. It is recommended that this standard set of surgical guides should accommodate pedicle screw diameters of 3.5-6 mm and transverse pedicle screw angles of 3.5°-12.4°.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Masculino , Femenino , Humanos , Vértebras Torácicas/anatomía & histología , Vértebras Torácicas/cirugía , Fusión Vertebral/métodos
5.
Clin Biomech (Bristol, Avon) ; 107: 106032, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37348206

RESUMEN

BACKGROUND: In vivo evaluation of ankle joint biomechanics is key to investigating the effect of injuries on the mechanics of the joint and evaluating the effectiveness of treatments. The objectives of this study were to 1) investigate the kinematics and contact strains of the ankle joint and 2) to investigate the correlation between the tibiotalar joint contact strains and the prevalence of osteochondral lesions of the talus distribution. METHODS: Eight healthy human ankle joints were subjected to compressive load and 3 T MRIs were obtained before and after applying load. The MR images in combination with digital volume correlation enabled non-invasive measurement of ankle joint kinematics and tibiotalar joint contact strains in three dimensions. FINDINGS: The total translation of the calcaneus was smaller (0.48 ± 0.15 mm, p < 0.05) than the distal tibia (0.93 ± 0.16 mm) and the talus (1.03 ± 0.26 mm). These movements can produce compressive and shear joint contact strains (approaching 9%), which can cause development of lesions on joints. 87.5% of peak tensile, compressive, and shear strains in the tibiotalar joint took place in the medial and lateral zones. INTERPRETATION: The findings suggested that ankle bones translate independently from each other, and in some cases in opposite directions. These findings help explain the distribution of osteochondral lesions of the talus which have previously been observed to be in medial and lateral regions of the talar dome in 90% of cases. They also provide a reason for the central region of talar dome being less susceptible to developing osteochondral lesions.


Asunto(s)
Articulación del Tobillo , Astrágalo , Humanos , Articulación del Tobillo/diagnóstico por imagen , Tobillo , Fenómenos Biomecánicos , Astrágalo/diagnóstico por imagen , Imagen por Resonancia Magnética
6.
JOR Spine ; 6(2): e1232, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37361334

RESUMEN

Background: Nuclectomy, also known as nucleotomy, is a percutaneous surgical procedure performed to remove nucleus material from the center of the disc. Multiple techniques have been considered to perform a nuclectomy, however, the advantages and disadvantages of each are not well understood. Aims: This in vitro biomechanical investigation on human cadaveric specimens aimed to quantitatively compare three nuclectomy techniques performed using an automated shaver, rongeurs, and laser. Material & Methods: Comparisons were made in terms of mass, volume and location of material removal, changes in disc height, and stiffness. Fifteen vertebra-disc-vertebra lumbar specimens were acquired from six donors (40 ± 13 years) and split into three groups. Before and after nucleotomy axial mechanical tests were performed and T2-weighted 9.4T MRIs were acquired for each specimen. Results: When using the automated shaver and rongeurs similar volumes of disc material were removed (2.51 ± 1.10% and 2.76 ± 1.39% of the total disc volume, respectively), while considerably less material was removed using the laser (0.12 ± 0.07%). Nuclectomy using the automated shaver and rongeurs significantly reduced the toe-region stiffness (p = 0.036), while the reduction in the linear region stiffness was significant only for the rongeurs group (p = 0.011). Post-nuclectomy, 60% of the rongeurs group specimens showed changes in the endplate profile while 40% from the laser group showed subchondral marrow changes. Discussion: From the MRIs, homogeneous cavities were seen in the center of the disc when using the automated shaver. When using rongeurs, material was removed non-homogeneously both from the nucleus and annulus regions. Laser ablation formed small and localized cavities suggesting that the technique is not suitable to remove large volumes of material unless it is developed and optimized for this application. Conclusion: The results demonstrate that both rongeurs and automated shavers can be used to remove large volumes of NP material but the reduced risk of collateral damage to surrounding tissues suggests that the automated shaver may be more suitable.

7.
Front Bioeng Biotechnol ; 11: 1229388, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37849982

RESUMEN

Introduction: Nucleus replacement has been proposed as a treatment to restore biomechanics and relieve pain in degenerate intervertebral discs (IVDs). Multiple nucleus replacement devices (NRDs) have been developed, however, none are currently used routinely in clinic. A better understanding of the interactions between NRDs and surrounding tissues may provide insight into the causes of implant failure and provide target properties for future NRD designs. The aim of this study was to non-invasively quantify 3D strains within the IVD through three stages of nucleus replacement surgery: intact, post-nuclectomy, and post-treatment. Methods: Digital volume correlation (DVC) combined with 9.4T MRI was used to measure strains in seven human cadaveric specimens (42 ± 18 years) when axially compressed to 1 kN. Nucleus material was removed from each specimen creating a cavity that was filled with a hydrogel-based NRD. Results: Nucleus removal led to loss of disc height (12.6 ± 4.4%, p = 0.004) which was restored post-treatment (within 5.3 ± 3.1% of the intact state, p > 0.05). Nuclectomy led to increased circumferential strains in the lateral annulus region compared to the intact state (-4.0 ± 3.4% vs. 1.7 ± 6.0%, p = 0.013), and increased maximum shear strains in the posterior annulus region (14.6 ± 1.7% vs. 19.4 ± 2.6%, p = 0.021). In both cases, the NRD was able to restore these strain values to their intact levels (p ≥ 0.192). Discussion: The ability of the NRD to restore IVD biomechanics and some strain types to intact state levels supports nucleus replacement surgery as a viable treatment option. The DVC-MRI method used in the present study could serve as a useful tool to assess future NRD designs to help improve performance in future clinical trials.

8.
Inj Prev ; 18(2): 109-12, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21768614

RESUMEN

BACKGROUND: Improvised explosive devices have become the characteristic weapon of conflicts in Iraq and Afghanistan. While little can be done to mitigate against the effects of blast in free-field explosions, scaled blast simulations have shown that the combat boot can attenuate the effects on the vehicle occupants of anti-vehicular mine blasts. Although the combat boot offers some protection to the lower limb, its behaviour at the energies seen in anti-vehicular mine blast has not been documented previously. METHODS: The sole of eight same-size combat boots from two brands currently used by UK troops deployed to Iraq and Afghanistan were impacted at energies of up to 518 J, using a spring-assisted drop rig. RESULTS: The results showed that the Meindl Desert Fox combat boot consistently experienced a lower peak force at lower impact energies and a longer time-to-peak force at higher impact energies when compared with the Lowa Desert Fox combat boot. DISCUSSION: This reduction in the peak force and extended rise time, resulting in a lower energy transfer rate, is a potentially positive mitigating effect in terms of the trauma experienced by the lower limb. CONCLUSION: Currently, combat boots are tested under impact at the energies seen during heel strike in running. Through the identification of significantly different behaviours at high loading, this study has shown that there is rationale in adding the performance of combat boots under impact at energies above those set out in international standards to the list of criteria for the selection of a combat boot.


Asunto(s)
Traumatismos por Explosión/prevención & control , Personal Militar , Ropa de Protección/normas , Carrera , Zapatos/normas , Caminata , Diseño de Equipo , Traumatismos de la Pierna/prevención & control , Ensayo de Materiales , Estrés Mecánico
9.
J Mech Behav Biomed Mater ; 129: 105150, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35272150

RESUMEN

Intervertebral disc (IVD) degeneration has been linked to Low Back Pain (LBP) which affects over 80% of the population ranking first in terms of disability worldwide. Degeneration progresses with age and is often accompanied by annulus fibrosus (AF) tearing and nucleus pulposus (NP) herniation. Existing therapies fail to restore IVD function and may worsen AF defects, increasing the risk of reherniation in nearly 30% of patients. Current AF closure options are ineffective, presenting biological or mechanical limitations. Bioadhesives have potential use in this area, however methods to assess performance are limited. Herein, we propose a biomechanical testing method to assess bioadhesives' capacity to seal AF tears. Two candidate bioadhesives to seal AF tears were evaluated; a tough hydrogel adhesive, and a cyanoacrylate-based glue. The adhesion energy at the interface between bovine discs and the tough hydrogel adhesive was quantified using a peel test (n=4). An experimental method to measure the burst pressure of IVDs was then developed. This method was used to quantify the burst pressure of intact (n=7), injured (AF punctured with a 21G needle; n=7), and sealed IVDs (after applying either the tough hydrogel adhesive patch as a sealant; n=5, or the cyanoacrylate-based glue over the AF tear; n=6). The tough adhesive yielded a strong adhesion energy of 239 ± 49 J/m2 during the peel tests. A maximum pressure of 13.2 ± 3.8 MPa was observed for intact discs in the burst pressure tests, which reduced by 61.4% to 5.1 ± 1.5 MPa in the injured IVDs (p < 0.01)). Application of a cyanoacrylate-based glue to injured IVDs did not recover the burst pressure with statistical significance, however, application of the tough adhesive to injured IVDs, restored burst pressure to 12.3 ± 4.5 MPa, which was not significantly different to the intact burst pressures. In this study, a simple biomechanical method to assess the performance of bioadhesives to seal AF tears based upon burst pressure has been established. Using this method it was found that a tough hydrogel adhesive was able to seal an AF injury, such that the IVD burst pressures were similar to those measured in intact specimens. This method can be used to provide a biomechanical assessment of bioadhesives under high magnitude loading and can complement existing cyclic testing methods that are currently used to assess AF closure devices, improving their assessment before clinical use.


Asunto(s)
Anillo Fibroso , Degeneración del Disco Intervertebral , Disco Intervertebral , Adhesivos Tisulares , Adhesivos , Animales , Bovinos , Cianoacrilatos , Humanos , Hidrogeles/uso terapéutico
10.
Prosthet Orthot Int ; 46(4): e374-e382, 2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-35324549

RESUMEN

OBJECTIVE: Obtaining patient geometry is crucial in scoliosis brace design for patients with adolescent idiopathic scoliosis. Advances in 3D scanning technologies provide the opportunity to obtain patient geometries quickly with fewer resources during the design process compared with the plaster-cast method. This study assesses the accuracy and repeatability of such technologies for this application. METHODS: The accuracy and repeatability of three different handheld scanners and phone-photogrammetry was assessed using different mesh generation software. Twenty-four scans of a single subject's torso were analyzed for accuracy and repeatability based on anatomical landmark distances and surface deviation maps. RESULTS: Mark II and Structure ST01 scanners showed maximum mean surface deviations of 1.74 ± 3.63 mm and 1.64 ± 3.06 mm, respectively. Deviations were lower for the Peel 1 scanner (maximum of -0.35 ± 2.8 mm) but higher with the use of phone-photogrammetry (maximum of -5.1 ± 4.8 mm). The mean absolute errors of anatomical landmark distance measurements from torso meshes obtained with the Peel 1, Mark II, and ST01 scanners were all within 9.3 mm (3.6%), whereas phone-photogrammetry errors were as high as 18 mm (7%). CONCLUSIONS: Low-cost Mark II and ST01 scanners are recommended for obtaining torso geometries because of their accuracy and repeatability. Subject's breathing/movement affects the resultant geometry around the abdominal and anterolateral regions.


Asunto(s)
Tirantes , Escoliosis , Adolescente , Humanos , Imagenología Tridimensional/métodos , Fotogrametría , Escoliosis/diagnóstico por imagen , Torso
11.
Front Bioeng Biotechnol ; 9: 660013, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34222211

RESUMEN

Finite element models are useful for investigating internal intervertebral disc (IVD) behaviours without using disruptive experimental techniques. Simplified geometries are commonly used to reduce computational time or because internal geometries cannot be acquired from CT scans. This study aimed to (1) investigate the effect of altered geometries both at endplates and the nucleus-anulus boundary on model response, and (2) to investigate model sensitivity to material and geometric inputs, and different modelling approaches (graduated or consistent fibre bundle angles and glued or cohesive inter-lamellar contact). Six models were developed from 9.4 T MRIs of bovine IVDs. Models had two variations of endplate geometry (a simple curved profile from the centre of the disc to the periphery, and precise geometry segmented from MRIs), and three variations of NP-AF boundary (linear, curved, and segmented). Models were subjected to axial compressive loading (to 0.86 mm at a strain rate of 0.1/s) and the effect on stiffness and strain distributions, and the sensitivity to modelling approaches was investigated. The model with the most complex geometry (segmented endplates, curved NP-AF boundary) was 3.1 times stiffer than the model with the simplest geometry (curved endplates, linear NP-AF boundary), although this difference may be exaggerated since segmenting the endplates in the complex geometry models resulted in a shorter average disc height. Peak strains were close to the endplates at locations of high curvature in the segmented endplate models which were not captured in the curved endplate models. Differences were also seen in sensitivity to material properties, graduated fibre angles, cohesive rather than glued inter-lamellar contact, and NP:AF ratios. These results show that FE modellers must take care to ensure geometries are realistic so that load is distributed and passes through IVDs accurately.

12.
Materials (Basel) ; 13(23)2020 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-33255848

RESUMEN

Strains within bone play an important role in the remodelling process and the mechanisms of fracture. The ability to assess these strains in vivo can provide clinically relevant information regarding bone health, injury risk, and can also be used to optimise treatments. In vivo bone strains have been investigated using multiple experimental techniques, but none have quantified 3D strains using non-invasive techniques. Digital volume correlation based on clinical MRI (DVC-MRI) is a non-invasive technique that has the potential to achieve this. However, before it can be implemented, uncertainties associated with the measurements must be quantified. Here, DVC-MRI was evaluated to assess its potential to measure in vivo strains in the talus. A zero-strain test (two repeated unloaded scans) was conducted using three MRI sequences, and three DVC approaches to quantify errors and to establish optimal settings. With optimal settings, strains could be measured with a precision of 200 µÎµ and accuracy of 480 µÎµ for a spatial resolution of 7.5 mm, and a precision of 133 µÎµ and accuracy of 251 µÎµ for a spatial resolution of 10 mm. These results demonstrate that this technique has the potential to measure relevant levels of in vivo bone strain and to be used for a range of clinical applications.

13.
JOR Spine ; 3(3): e21110, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33015585

RESUMEN

In vitro mechanical testing of intervertebral discs is crucial for basic science and pre-clinical testing. Generally, these tests aim to replicate in vivo conditions, but simplifications are necessary in specimen preparation and mechanical testing due to complexities in both structure and the loading conditions required to replicate in vivo conditions. There has been a growing interest in developing a consensus of testing protocols within the spine community to improve comparison of results between studies. The objective of this study was to perform axial compression experiments on bovine bone-disc-bone specimens at three institutions. No differences were observed between testing environment being air, with PBS soaked gauze, or a PBS bath (P > .206). A 100-fold increase in loading rate resulted in a small (2%) but significant increase in compressive mechanics (P < .017). A 7% difference in compressive stiffness between Labs B and C was eliminated when values were adjusted for test system compliance. Specimens tested at Lab A, however, were found to be stiffer than specimens from Lab B and C. Even after normalizing for disc geometry and adjusting for system compliance, an ∼35% difference was observed between UK based labs (B and C) and the USA based lab (A). Large differences in specimen stiffness may be due to genetic differences between breeds or in agricultural feed and use of growth hormones; highlighting significant challenges in comparing mechanics data across studies. This research provides a standardized test protocol for the comparison of spinal specimens and provides steps towards understanding how location and test set-up may affect biomechanical results.

14.
Front Bioeng Biotechnol ; 8: 610907, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33553116

RESUMEN

The intervertebral disc (IVD) plays a main role in absorbing and transmitting loads within the spinal column. Degeneration alters the structural integrity of the IVDs and causes pain, especially in the lumbar region. The objective of this study was to investigate non-invasively the effect of degeneration on human 3D lumbar IVD strains (n = 8) and the mechanism of spinal failure (n = 10) under pure axial compression using digital volume correlation (DVC) and 9.4 Tesla magnetic resonance imaging (MRI). Degenerate IVDs had higher (p < 0.05) axial strains (58% higher), maximum 3D compressive strains (43% higher), and maximum 3D shear strains (41% higher), in comparison to the non-degenerate IVDs, particularly in the lateral and posterior annulus. In both degenerate and non-degenerate IVDs, peak tensile and shear strains were observed close to the endplates. Inward bulging of the inner annulus was observed in all degenerate IVDs causing an increase in the AF compressive, tensile, and shear strains at the site of inward bulge, which may predispose it to circumferential tears (delamination). The endplate is the spine's "weak link" in pure axial compression, and the mechanism of human vertebral fracture is associated with disc degeneration. In non-degenerate IVDs the locations of failure were close to the endplate centroid, whereas in degenerate IVDs they were in peripheral regions. These findings advance the state of knowledge on mechanical changes during degeneration of the IVD, which help reduce the risk of injury, optimize treatments, and improve spinal implant designs. Additionally, these new data can be used to validate computational models.

15.
Spine J ; 19(12): 2013-2024, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31326631

RESUMEN

BACKGROUND CONTEXT: The use of finite element (FE) methods to study the biomechanics of the intervertebral disc (IVD) has increased over recent decades due to their ability to quantify internal stresses and strains throughout the tissue. Their accuracy is dependent upon realistic, strain-rate dependent material properties, which are challenging to acquire. PURPOSE: The aim of this study was to use the inverse FE technique to characterize the material properties of human lumbar IVDs across strain rates. STUDY DESIGN: A human cadaveric experimental study coupled with an inverse finite element study. METHODS: To predict the structural response of the IVD accurately, the material response of the constituent structures was required. Therefore, compressive experiments were conducted on 16 lumbar IVDs (39±19 years) to obtain the structural response. An FE model of each of these experiments was developed and then run through an inverse FE algorithm to obtain subject-specific constituent material properties, such that the structural response was accurate. RESULTS: Experimentally, a log-linear relationship between IVD stiffness and strain rate was observed. The material properties obtained through the subject-specific inverse FE optimization of the annulus fibrosus (AF) fiber and AF fiber ground matrix allowed a good match between the experimental and FE response. This resulted in a Young modulus of AF fibers (-MPa) to strain rate (ε˙, /s) relationship of YMAF=31.5ln(ε˙)+435.5, and the C10 parameter of the Neo-Hookean material model of the AF ground matrix was found to be strain-rate independent with an average value of 0.68 MPa. CONCLUSIONS: These material properties can be used to improve the accuracy, and therefore predictive ability of FE models of the spine that are used in a wide range of research areas and clinical applications. CLINICAL SIGNIFICANCE: Finite element models can be used for many applications including investigating low back pain, spinal deformities, injury biomechanics, implant design, design of protective systems, and degenerative disc disease. The accurate material properties obtained in this study will improve the predictive ability, and therefore clinical significance of these models.


Asunto(s)
Anillo Fibroso/fisiología , Módulo de Elasticidad , Vértebras Lumbares/fisiología , Fenómenos Biomecánicos , Análisis de Elementos Finitos , Humanos , Estrés Mecánico
16.
Spine (Phila Pa 1976) ; 44(15): 1035-1041, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-31095121

RESUMEN

STUDY DESIGN: Bovine motion segments were used to investigate the high-rate compression response of intervertebral discs (IVD) before and after depressurising the nucleus pulposus (NP) by drilling a hole through the cranial endplate into it. OBJECTIVE: To investigate the effect of depressurising the NP on the force-displacement response, and the energy absorption in IVDs when compressed at high strain rates. SUMMARY OF BACKGROUND DATA: The mechanical function of the gelatinous NP located in the center of the IVDs of the spine is unclear. Removal of the NP has been shown to affect the direction of bulge of the inner anulus fibrosus (AF), but at low loading rates removal of the NP pressure does not affect the IVD's stiffness. During sports or injurious events, IVDs are commonly exposed to high loading rates, however, no studies have investigated the mechanical function of the NP at these rates. METHODS: Eight bovine motion segments were used to quantify the change in pressure caused by a hole drilled through the cranial endplate into the NP, and eight segments were used to investigate the high-rate response before and after a hole was drilled into the NP. RESULTS: The hole caused a 28.5% drop in the NP pressure. No statistically significant difference was seen in peak force, peak displacement, or energy-absorption of the intact, and depressurized NP groups under impact loading. The IVDs absorbed 72% of the input energy, and there was no rate dependency in the percentage energy absorbed. CONCLUSION: These results demonstrate that the NP pressure does not affect the transfer of load through, or energy absorbed by, the IVD at high loading rates and the AF, rather than the NP, may play the most important role in transferring load, and absorbing energy at these rates. This should be considered when attempting surgically to restore IVD function. LEVEL OF EVIDENCE: N/A.


Asunto(s)
Disco Intervertebral/fisiología , Núcleo Pulposo/fisiología , Animales , Anillo Fibroso/fisiología , Bovinos , Degeneración del Disco Intervertebral
17.
Ann Biomed Eng ; 47(1): 306-316, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30276492

RESUMEN

Over 80% of wounded Service Members sustain at least one extremity injury. The 'deck-slap' foot, a product of the vehicle's floor rising rapidly when attacked by a mine to injure the limb, has been a signature injury in recent conflicts. Given the frequency and severity of these combat-related extremity injuries, they require the greatest utilisation of resources for treatment, and have caused the greatest number of disabled soldiers during recent conflicts. Most research efforts focus on occupants seated with both tibia-to-femur and tibia-to-foot angles set at 90°; it is unknown whether results obtained from these tests are applicable when alternative seated postures are adopted. To investigate this, lower limbs from anthropometric testing devices (ATDs) and post mortem human subjects (PMHSs) were loaded in three different seated postures using an under-body blast injury simulator. Using metrics that are commonly used for assessing injury, such as the axial force and the revised tibia index, the lower limb of ATDs were found to be insensitive to posture variations while the injuries sustained by the PMHS lower limbs differed in type and severity between postures. This suggests that the mechanism of injury depends on the posture and that this cannot be captured by the current injury criteria. Therefore, great care should be taken when interpreting and extrapolating results, especially in vehicle qualification tests, when postures other than the 90°-90° are of interest.


Asunto(s)
Traumatismos por Explosión , Fémur , Pie , Modelos Biológicos , Equilibrio Postural , Tibia , Traumatismos por Explosión/patología , Traumatismos por Explosión/fisiopatología , Femenino , Fémur/patología , Fémur/fisiopatología , Pie/patología , Pie/fisiopatología , Humanos , Masculino , Tibia/patología , Tibia/fisiopatología
18.
J Trauma Acute Care Surg ; 85(1S Suppl 2): S129-S133, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29370057

RESUMEN

BACKGROUND: Personnel have sustained a range of devastating blast injuries during recent conflicts. Previous studies have focused on severe injuries, including to the spine; however, no study has specifically focused on the most common spinal injury-transverse process (TP) fractures. Although their treatment usually requires limited intervention, analysis of TP fractures may help determine injury mechanisms. METHODS: Data were collected from victims with spinal fractures who were injured in improvised explosive device attacks, from the UK's Joint Theatre Trauma Registry. The level and side of each TP fracture were recorded, as well as associated injuries, whether they were mounted or dismounted, and outcome (survivor or fatality). RESULTS: Most (80%) of the TP fractures were lumbar. More bilateral (both left and right fractures at the same level), and L5 TP fractures, were seen in fatalities than survivors. In the mounted group, lumbar TP fractures were statistically significantly associated with fatality, head injury, noncompressible torso hemorrhage, pelvic injury, and other spinal injuries. In the dismounted group, thoracic TP fractures were associated with head, chest wall, and other spinal injuries; and lumbar TP fractures were associated with pelvic and other spinal injuries. CONCLUSIONS: Different injury mechanisms of the TP in the mounted and dismounted groups are likely. Inertial forces acting within the torso due to rapid loading being transferred through the seat, or high intra-abdominal pressures causing the tensile forces acting through the lumbar fascia to avulse the TPs are likely mechanisms in the mounted group. Blunt trauma, violent lateral flexion-extension forces, or rapid flail of the lower extremities causing tension of the psoas muscle, avulsing the TP, are likely causes in the dismounted group. Isolated lumbar TP fractures can be used as markers for more severe injuries, and fatality, in mounted blast casualties. LEVEL OF EVIDENCE: Prognostic and epidemiological, level III.


Asunto(s)
Traumatismos por Explosión/complicaciones , Fracturas de la Columna Vertebral/complicaciones , Heridas Relacionadas con la Guerra/complicaciones , Campaña Afgana 2001- , Traumatismos por Explosión/mortalidad , Vértebras Cervicales/lesiones , Humanos , Guerra de Irak 2003-2011 , Vértebras Lumbares/lesiones , Sistema de Registros , Estudios Retrospectivos , Fracturas de la Columna Vertebral/mortalidad , Vértebras Torácicas/lesiones , Reino Unido
19.
J Mech Behav Biomed Mater ; 65: 824-830, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27810728

RESUMEN

The intervertebral disc (IVD) is a complex structure responsible for distributing compressive loading to adjacent vertebrae and allowing the vertebral column to bend and twist. To study the mechanical behaviour of individual components of the IVD, it is common for specimens to be dissected away from their surrounding tissues for mechanical testing. However, disrupting the continuity of the IVD to obtain material properties of each component separately may result in erroneous values. In this study, an inverse finite element (FE) modelling optimisation algorithm has been used to obtain material properties of the IVD across strain rates, therefore bypassing the need to harvest individual samples of each component. Uniaxial compression was applied to ten fresh-frozen bovine intervertebral discs at strain rates of 10-3-1/s. The experimental data were fed into the inverse FE optimisation algorithm and each experiment was simulated using the subject specific FE model of the respective specimen. A sensitivity analysis revealed that the IVD's response was most dependent upon the Young's modulus (YM) of the fibre bundles and therefore this was chosen to be the parameter to optimise. Based on the obtained YM values for each test corresponding to a different strain rate (ε̇), the following relationship was derived:YM=35.5lnε̇+527.5. These properties can be used in finite element models of the IVD that aim to simulate spinal biomechanics across loading rates.


Asunto(s)
Disco Intervertebral/fisiología , Vértebras Lumbares/fisiología , Algoritmos , Animales , Fenómenos Biomecánicos , Bovinos , Módulo de Elasticidad , Análisis de Elementos Finitos , Estrés Mecánico
20.
Med Biol Eng Comput ; 55(4): 561-572, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27364618

RESUMEN

Adolescent idiopathic scoliosis (AIS) is a three-dimensional (3D) spinal deformity of unknown aetiology. Increased growth of the anterior part of the vertebrae known as anterior overgrowth has been proposed as a potential driver for AIS initiation and progression. To date, there has been no objective evaluation of the 3D measurement techniques used to identify this phenomenon and the majority of previous studies use 2D planar assessments which contain inherent projection errors due to the vertebral rotation which is part of the AIS deformity. In this study, vertebral body (VB) heights and wedge angles were measured in a test group of AIS patients and healthy controls using four different image analysis and measurement techniques. Significant differences were seen between the techniques in terms of VB heights and VB wedge angles. The low variability, and the fact that the rotation and tilt of the deformed VBs are taken into account, suggests that the proposed technique using the full 3D orientation of the vertebrae is the most reliable method to measure anterior and posterior VB heights and sagittal plane wedge angles in 3D image data sets. These results have relevance for future investigations that aim to quantify anterior overgrowth in AIS patients for comparison with healthy controls.


Asunto(s)
Estatura , Procesamiento de Imagen Asistido por Computador/métodos , Escoliosis/diagnóstico por imagen , Escoliosis/fisiopatología , Estudios de Casos y Controles , Niño , Femenino , Humanos , Imagen por Resonancia Magnética , Columna Vertebral/diagnóstico por imagen , Columna Vertebral/crecimiento & desarrollo , Columna Vertebral/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA