Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Neuromodulation ; 25(2): 232-244, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35125142

RESUMEN

INTRODUCTION: The hippocampus is thought to be involved in movement, but its precise role in movement execution and inhibition has not been well studied. Previous work with direct neural recordings has found beta-band (13-30 Hz) modulation in both movement execution and inhibition throughout the motor system, but the role of beta-band modulation in the hippocampus during movement inhibition is not well understood. Here, we perform a Go/No-Go reaching task in ten patients with medically refractory epilepsy to study human hippocampal beta-power changes during movement. MATERIALS AND METHODS: Ten epilepsy patients (5 female; ages 21-46) were implanted with intracranial depth electrodes for seizure monitoring and localization. Local field potentials were sampled at 2000 Hz during a Go/No-Go movement task. Comparison of beta-band power between Go and No-Go conditions was conducted using Wilcoxon signed-rank hypothesis testing for each patient. Sub-analyses were conducted to assess differences in the anterior vs posterior contacts, ipsilateral vs contralateral contacts, and male vs female beta-power values. RESULTS: Eight out of ten patients showed significant beta-power decreases during the Go movement response (p < 0.05) compared to baseline. Eight out of ten patients also showed significant beta-power increases in the No-Go condition, occurring in the absence of movement. No significant differences were noted between ipsilateral vs contralateral contacts nor in anterior vs posterior hippocampal contacts. Female participants had a higher task success rate than males and had significantly greater beta-power increases in the No-Go condition (p < 0.001). CONCLUSION: These findings indicate that increases in hippocampal beta power are associated with movement inhibition. To the best of our knowledge, this study is the first to report this phenomenon in the human hippocampus. The beta band may represent a state-change signal involved in motor processing. Future focus on the beta band in understanding human motor and impulse control will be vital.


Asunto(s)
Electroencefalografía , Epilepsia , Adulto , Epilepsia/terapia , Femenino , Hipocampo , Humanos , Masculino , Persona de Mediana Edad , Movimiento , Adulto Joven
2.
Neurosurg Focus ; 48(2): E2, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-32006952

RESUMEN

OBJECTIVE: Stimulation of the primary somatosensory cortex (S1) has been successful in evoking artificial somatosensation in both humans and animals, but much is unknown about the optimal stimulation parameters needed to generate robust percepts of somatosensation. In this study, the authors investigated frequency as an adjustable stimulation parameter for artificial somatosensation in a closed-loop brain-computer interface (BCI) system. METHODS: Three epilepsy patients with subdural mini-electrocorticography grids over the hand area of S1 were asked to compare the percepts elicited with different stimulation frequencies. Amplitude, pulse width, and duration were held constant across all trials. In each trial, subjects experienced 2 stimuli and reported which they thought was given at a higher stimulation frequency. Two paradigms were used: first, 50 versus 100 Hz to establish the utility of comparing frequencies, and then 2, 5, 10, 20, 50, or 100 Hz were pseudorandomly compared. RESULTS: As the magnitude of the stimulation frequency was increased, subjects described percepts that were "more intense" or "faster." Cumulatively, the participants achieved 98.0% accuracy when comparing stimulation at 50 and 100 Hz. In the second paradigm, the corresponding overall accuracy was 73.3%. If both tested frequencies were less than or equal to 10 Hz, accuracy was 41.7% and increased to 79.4% when one frequency was greater than 10 Hz (p = 0.01). When both stimulation frequencies were 20 Hz or less, accuracy was 40.7% compared with 91.7% when one frequency was greater than 20 Hz (p < 0.001). Accuracy was 85% in trials in which 50 Hz was the higher stimulation frequency. Therefore, the lower limit of detection occurred at 20 Hz, and accuracy decreased significantly when lower frequencies were tested. In trials testing 10 Hz versus 20 Hz, accuracy was 16.7% compared with 85.7% in trials testing 20 Hz versus 50 Hz (p < 0.05). Accuracy was greater than chance at frequency differences greater than or equal to 30 Hz. CONCLUSIONS: Frequencies greater than 20 Hz may be used as an adjustable parameter to elicit distinguishable percepts. These findings may be useful in informing the settings and the degrees of freedom achievable in future BCI systems.


Asunto(s)
Interfaces Cerebro-Computador/normas , Epilepsia Refractaria/fisiopatología , Electrocorticografía/métodos , Electrodos Implantados/normas , Desempeño Psicomotor/fisiología , Corteza Somatosensorial/fisiología , Epilepsia Refractaria/diagnóstico por imagen , Estimulación Eléctrica/métodos , Electrocorticografía/instrumentación , Humanos , Imagen por Resonancia Magnética/métodos , Distribución Aleatoria , Tomografía Computarizada por Rayos X/métodos
3.
Neurosurg Focus ; 49(1): E4, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32610288

RESUMEN

OBJECTIVE: Motor brain-computer interface (BCI) represents a new frontier in neurological surgery that could provide significant benefits for patients living with motor deficits. Both the primary motor cortex and posterior parietal cortex have successfully been used as a neural source for human motor BCI, leading to interest in exploring other brain areas involved in motor control. The amygdala is one area that has been shown to have functional connectivity to the motor system; however, its role in movement execution is not well studied. Gamma oscillations (30-200 Hz) are known to be prokinetic in the human cortex, but their role is poorly understood in subcortical structures. Here, the authors use direct electrophysiological recordings and the classic "center-out" direct-reach experiment to study amygdaloid gamma-band modulation in 8 patients with medically refractory epilepsy. METHODS: The study population consisted of 8 epilepsy patients (2 men; age range 21-62 years) who underwent implantation of micro-macro depth electrodes for seizure localization and EEG monitoring. Data from the macro contacts sampled at 2000 Hz were used for analysis. The classic center-out direct-reach experiment was used, which consists of an intertrial interval phase, a fixation phase, and a response phase. The authors assessed the statistical significance of neural modulation by inspecting for nonoverlapping areas in the 95% confidence intervals of spectral power for the response and fixation phases. RESULTS: In 5 of the 8 patients, power spectral analysis showed a statistically significant increase in power within regions of the gamma band during the response phase compared with the fixation phase. In these 5 patients, the 95% bootstrapped confidence intervals of trial-averaged power in contiguous frequencies of the gamma band during the response phase were above, and did not overlap with, the confidence intervals of trial-averaged power during the fixation phase. CONCLUSIONS: To the authors' knowledge, this is the first time that direct neural recordings have been used to show gamma-band modulation in the human amygdala during the execution of voluntary movement. This work indicates that gamma-band modulation in the amygdala could be a contributing source of neural signals for use in a motor BCI system.


Asunto(s)
Amígdala del Cerebelo/fisiología , Epilepsia/fisiopatología , Movimiento/fisiología , Red Nerviosa/fisiología , Encéfalo/fisiología , Electroencefalografía/métodos , Humanos , Corteza Motora/fisiología , Lóbulo Parietal/fisiología
4.
Exp Brain Res ; 237(5): 1155-1167, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30796470

RESUMEN

OBJECTIVE: Restoration of somatosensory deficits in humans requires a clear understanding of the neural representations of percepts. To characterize the cortical response to naturalistic somatosensation, we examined field potentials in the primary somatosensory cortex of humans. METHODS: Four patients with intractable epilepsy were implanted with subdural electrocorticography (ECoG) electrodes over the hand area of S1. Three types of stimuli were applied, soft-repetitive touch, light touch, and deep touch. Power in the alpha (8-15 Hz), beta (15-30 Hz), low-gamma (30-50 Hz), and high-gamma (50-125 Hz) frequency bands were evaluated for significance. RESULTS: Seventy-seven percent of electrodes over the hand area of somatosensory cortex exhibited changes in these bands. High-gamma band power increased for all stimuli, with concurrent alpha and beta band power decreases. Earlier activity was seen in these bands in deep touch and light touch compared to soft touch. CONCLUSIONS: These findings are consistent with prior literature and suggest a widespread response to focal touch, and a different encoding of deeper pressure touch than soft touch.


Asunto(s)
Ondas Encefálicas/fisiología , Electrocorticografía/métodos , Mano/fisiología , Corteza Somatosensorial/fisiología , Adulto , Estimulación Eléctrica , Electrodos Implantados , Epilepsia/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
5.
Epilepsy Behav ; 42: 140-6, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25450530

RESUMEN

OBJECTIVE: The impact of epilepsy is manifest by effects related to seizures and side effects of therapy and comorbidities such as depression. This report describes the development of a brief patient-reported outcome (PRO) instrument, the Personal Impact of Epilepsy Scale (PIES), to measure the influence of epilepsy overall and in each of these domains. METHODS: Instrument development followed standard procedures and an FDA Guidance. People with epilepsy were surveyed with open-ended questions to derive major themes of their concerns, resulting in 4 key areas: seizures, side effects, comorbidities, and overall quality of life (QOL). A preliminary set of 152 questions was based on these themes and completed by 50 patients, age 42.7 (range: 21-71) years, concurrent with comparator instruments, including the NH Seizure Severity Scale (NHSSS), the Liverpool Adverse Events Profile (LAEP), the Quality of Life in Epilepsy (QOLIE-31) scale, the Beck Depression Inventory, and the Epilepsy Foundation Depression: A Checklist. A multiple regression model indicated which PIES measures were associated with scores from the comparator instruments. Questions in each of the domains were selected for correlations and nonduplication. Test-retest consistency at a 3-day interval was completed by 38 subjects and a final set of questions constructed. RESULTS: The final question set comprised 25 items: 9 about characteristics of seizures, 7 about medication side effects, 8 about comorbidities, and 1 about overall quality of life. All items had 5 response choices (0-4), with higher scores reflecting more negative status. A total of 46 subjects completed the 25 questions. Cronbach's alpha was 0.87, indicating good internal consistency. Each of the three domains correlated well with the overall QOL item. The questions pertaining to seizures correlated with the NHSSS, the side effect questions with the LAEP, and the comorbidity questions with the QOLIE-31. CONCLUSION: The PIES provides a simple, brief PRO measure as a profile of overall impact of seizures, medication side effects, comorbidities, and overall QOL for people with epilepsy. Further study will explore sensitivity to change quantification of the minimal clinically significant change.


Asunto(s)
Epilepsia/psicología , Escalas de Valoración Psiquiátrica/normas , Psicometría/instrumentación , Calidad de Vida , Adulto , Anciano , Anticonvulsivantes/efectos adversos , Comorbilidad , Depresión/epidemiología , Epilepsia/tratamiento farmacológico , Epilepsia/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Convulsiones/tratamiento farmacológico , Convulsiones/epidemiología , Convulsiones/psicología , Adulto Joven
6.
Front Comput Neurosci ; 18: 1263311, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38390007

RESUMEN

Objective: Here, we demonstrate the first successful use of static neural stimulation patterns for specific information content. These static patterns were derived by a model that was applied to a subject's own hippocampal spatiotemporal neural codes for memory. Approach: We constructed a new model of processes by which the hippocampus encodes specific memory items via spatiotemporal firing of neural ensembles that underlie the successful encoding of targeted content into short-term memory. A memory decoding model (MDM) of hippocampal CA3 and CA1 neural firing was computed which derives a stimulation pattern for CA1 and CA3 neurons to be applied during the encoding (sample) phase of a delayed match-to-sample (DMS) human short-term memory task. Main results: MDM electrical stimulation delivered to the CA1 and CA3 locations in the hippocampus during the sample phase of DMS trials facilitated memory of images from the DMS task during a delayed recognition (DR) task that also included control images that were not from the DMS task. Across all subjects, the stimulated trials exhibited significant changes in performance in 22.4% of patient and category combinations. Changes in performance were a combination of both increased memory performance and decreased memory performance, with increases in performance occurring at almost 2 to 1 relative to decreases in performance. Across patients with impaired memory that received bilateral stimulation, significant changes in over 37.9% of patient and category combinations was seen with the changes in memory performance show a ratio of increased to decreased performance of over 4 to 1. Modification of memory performance was dependent on whether memory function was intact or impaired, and if stimulation was applied bilaterally or unilaterally, with nearly all increase in performance seen in subjects with impaired memory receiving bilateral stimulation. Significance: These results demonstrate that memory encoding in patients with impaired memory function can be facilitated for specific memory content, which offers a stimulation method for a future implantable neural prosthetic to improve human memory.

7.
Clin Neurophysiol ; 152: 93-111, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37208270

RESUMEN

Neurostimulation has diverse clinical applications and potential as a treatment for medically refractory movement disorders, epilepsy, and other neurological disorders. However, the parameters used to program electrodes-polarity, pulse width, amplitude, and frequency-and how they are adjusted have remained largely untouched since the 1970 s. This review summarizes the state-of-the-art in Deep Brain Stimulation (DBS) and highlights the need for further research to uncover the physiological mechanisms of neurostimulation. We focus on studies that reveal the potential for clinicians to use waveform parameters to selectively stimulate neural tissue for therapeutic benefit, while avoiding activating tissue associated with adverse effects. DBS uses cathodic monophasic rectangular pulses with passive recharging in clinical practice to treat neurological conditions such as Parkinson's Disease. However, research has shown that stimulation efficiency can be improved, and side effects reduced, through modulating parameters and adding novel waveform properties. These developments can prolong implantable pulse generator lifespan, reducing costs and surgery-associated risks. Waveform parameters can stimulate neurons based on axon orientation and intrinsic structural properties, providing clinicians with more precise targeting of neural pathways. These findings could expand the spectrum of diseases treatable with neuromodulation and improve patient outcomes.


Asunto(s)
Estimulación Encefálica Profunda , Enfermedades del Sistema Nervioso , Enfermedad de Parkinson , Humanos , Estimulación Encefálica Profunda/efectos adversos , Electrodos , Neurofisiología
8.
Front Cell Dev Biol ; 10: 969364, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36172274

RESUMEN

Acute brain insults trigger diverse cellular and signaling responses and often precipitate epilepsy. The cellular, molecular and signaling events relevant to the emergence of the epileptic brain, however, remain poorly understood. These multiplex structural and functional alterations tend also to be opposing - some homeostatic and reparative while others disruptive; some associated with growth and proliferation while others, with cell death. To differentiate pathological from protective consequences, we compared seizure-induced changes in gene expression hours and days following kainic acid (KA)-induced status epilepticus (SE) in postnatal day (P) 30 and P15 rats by capitalizing on age-dependent differential physiologic responses to KA-SE; only mature rats, not immature rats, have been shown to develop spontaneous recurrent seizures after KA-SE. To correlate gene expression profiles in epileptic rats with epilepsy patients and demonstrate the clinical relevance of our findings, we performed gene analysis on four patient samples obtained from temporal lobectomy and compared to four control brains from NICHD Brain Bank. Pro-inflammatory gene expressions were at higher magnitudes and more sustained in P30. The inflammatory response was driven by the cytokines IL-1ß, IL-6, and IL-18 in the acute period up to 72 h and by IL-18 in the subacute period through the 10-day time point. In addition, a panoply of other immune system genes was upregulated, including chemokines, glia markers and adhesion molecules. Genes associated with the mitogen activated protein kinase (MAPK) pathways comprised the largest functional group identified. Through the integration of multiple ontological databases, we analyzed genes belonging to 13 separate pathways linked to Classical MAPK ERK, as well as stress activated protein kinases (SAPKs) p38 and JNK. Interestingly, genes belonging to the Classical MAPK pathways were mostly transiently activated within the first 24 h, while genes in the SAPK pathways had divergent time courses of expression, showing sustained activation only in P30. Genes in P30 also had different regulatory functions than in P15: P30 animals showed marked increases in positive regulators of transcription, of signaling pathways as well as of MAPKKK cascades. Many of the same inflammation-related genes as in epileptic rats were significantly upregulated in human hippocampus, higher than in lateral temporal neocortex. They included glia-associated genes, cytokines, chemokines and adhesion molecules and MAPK pathway genes. Uniquely expressed in human hippocampus were adaptive immune system genes including immune receptors CDs and MHC II HLAs. In the brain, many immune molecules have additional roles in synaptic plasticity and the promotion of neurite outgrowth. We propose that persistent changes in inflammatory gene expression after SE leads not only to structural damage but also to aberrant synaptogenesis that may lead to epileptogenesis. Furthermore, the sustained pattern of inflammatory genes upregulated in the epileptic mature brain was distinct from that of the immature brain that show transient changes and are resistant to cell death and neuropathologic changes. Our data suggest that the epileptogenic process may be a result of failed cellular signaling mechanisms, where insults overwhelm the system beyond a homeostatic threshold.

9.
J Neural Eng ; 19(1)2022 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-35086075

RESUMEN

Objective. The human orbitofrontal cortex (OFC) is involved in automatic response inhibition and conflict processing, but the mechanism of frequency-specific power changes that control these functions is unknown. Theta and gamma activity have been independently observed in the OFC during conflict processing, while theta-gamma interactions in other brain areas have been noted primarily in studies of memory. Within the OFC, it is possible that theta-gamma phase amplitude coupling (PAC) drives conflict processing. This study aims to characterize the coupled relationship between theta and gamma frequency bands in the OFC during conflict processing using a modified Stroop task.Approach. Eight epilepsy patients implanted with OFC stereotactic electroencephalography electrodes participated in a color-word modified Stroop task. PAC between theta phase and gamma amplitude was assessed to determine the timing and magnitude of neural oscillatory changes. Group analysis was conducted using a non-parametric cluster-permutationt-test on coherence values.Main results.Theta-low gamma (LG) PAC significantly increased in five out of eight patients during successful trials of the incongruent condition compared with the congruent condition. Significant increases in theta-LG PAC were most prominent during cue processing 200-800 ms after cue presentation. On group analysis, trial-averaged mean theta-LG PAC was statistically significantly greater in the incongruent condition compared to the congruent condition (p< 0.001, Cohen'sd= 0.51).Significance.For the first time, we report that OFC theta phase and LG amplitude coupling increases during conflict resolution. Given the delayed onset after cue presentation, OFC theta-LG PAC may contribute to conflict processing after conflict detection and before motor response. This explanation follows the hypothesis that global theta waves modulate local gamma signals. Understanding this relationship within the OFC will help further elucidate the neural mechanisms of human conflict resolution.


Asunto(s)
Conflicto Psicológico , Corteza Prefrontal , Electroencefalografía , Epilepsia , Humanos , Corteza Prefrontal/fisiología , Test de Stroop
10.
J Neural Eng ; 19(4)2022 07 22.
Artículo en Inglés | MEDLINE | ID: mdl-35803209

RESUMEN

Objective.This study aimed to characterize hippocampal neural signatures of uncertainty by measuring beta band power in the period prior to movement cue.Approach. Participants with epilepsy were implanted with hippocampal depth electrodes for stereo electroencephalographic (SEEG) monitoring. Hippocampal beta (13-30 Hz) power changes have been observed during motor tasks such as the direct reach (DR) and Go/No-Go (GNG) tasks. The primary difference between the tasks is the presence of uncertainty about whether movement should be executed. Previous research on cortical responses to uncertainty has found that baseline beta power changes with uncertainty. SEEG data were sampled throughout phases of the DR and GNG tasks. Beta-band power during the fixation phase was compared between the DR and GNG task using a Wilcoxon rank sum test. This unpaired test was also used to analyze response times from cue to task completion between tasks.Main results.Eight patients who performed both reaching tasks were analyzed in this study. Movement response times in the GNG task were on average 210 milliseconds slower than in the DR task. All patients exhibited a significantly increased response latency in the GNG task compared to the DR task (Wilcoxon rank-sum p-value < 0.001). Six out of eight patients demonstrated statistically significant differences in beta power in single hippocampal contacts between the fixation phases of the GNG and DR tasks. At the group level, baseline beta power was significantly lower in the GNG task than in the DR task (Wilcoxon rank-sum p-value < 0.001).Significance. This novel study found that, in the presence of task uncertainty, baseline beta power in the hippocampus is lower than in its absence. This finding implicates movement uncertainty as an important factor in baseline hippocampal beta power during movement preparation.


Asunto(s)
Electroencefalografía , Movimiento , Hipocampo , Humanos , Movimiento/fisiología , Tiempo de Reacción/fisiología , Incertidumbre
11.
Front Hum Neurosci ; 16: 933401, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35959242

RESUMEN

RATIONALE: Deep brain stimulation (DBS) of the hippocampus is proposed for enhancement of memory impaired by injury or disease. Many pre-clinical DBS paradigms can be addressed in epilepsy patients undergoing intracranial monitoring for seizure localization, since they already have electrodes implanted in brain areas of interest. Even though epilepsy is usually not a memory disorder targeted by DBS, the studies can nevertheless model other memory-impacting disorders, such as Traumatic Brain Injury (TBI). METHODS: Human patients undergoing Phase II invasive monitoring for intractable epilepsy were implanted with depth electrodes capable of recording neurophysiological signals. Subjects performed a delayed-match-to-sample (DMS) memory task while hippocampal ensembles from CA1 and CA3 cell layers were recorded to estimate a multi-input, multi-output (MIMO) model of CA3-to-CA1 neural encoding and a memory decoding model (MDM) to decode memory information from CA3 and CA1 neuronal signals. After model estimation, subjects again performed the DMS task while either MIMO-based or MDM-based patterned stimulation was delivered to CA1 electrode sites during the encoding phase of the DMS trials. Each subject was sorted (post hoc) by prior experience of repeated and/or mild-to-moderate brain injury (RMBI), TBI, or no history (control) and scored for percentage successful delayed recognition (DR) recall on stimulated vs. non-stimulated DMS trials. The subject's medical history was unknown to the experimenters until after individual subject memory retention results were scored. RESULTS: When examined compared to control subjects, both TBI and RMBI subjects showed increased memory retention in response to both MIMO and MDM-based hippocampal stimulation. Furthermore, effects of stimulation were also greater in subjects who were evaluated as having pre-existing mild-to-moderate memory impairment. CONCLUSION: These results show that hippocampal stimulation for memory facilitation was more beneficial for subjects who had previously suffered a brain injury (other than epilepsy), compared to control (epilepsy) subjects who had not suffered a brain injury. This study demonstrates that the epilepsy/intracranial recording model can be extended to test the ability of DBS to restore memory function in subjects who previously suffered a brain injury other than epilepsy, and support further investigation into the beneficial effect of DBS in TBI patients.

13.
Nat Neurosci ; 25(4): 493-503, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35383330

RESUMEN

The hippocampus is the most common seizure focus in people. In the hippocampus, aberrant neurogenesis plays a critical role in the initiation and progression of epilepsy in rodent models, but it is unknown whether this also holds true in humans. To address this question, we used immunofluorescence on control healthy hippocampus and surgical resections from mesial temporal lobe epilepsy (MTLE), plus neural stem-cell cultures and multi-electrode recordings of ex vivo hippocampal slices. We found that a longer duration of epilepsy is associated with a sharp decline in neuronal production and persistent numbers in astrogenesis. Further, immature neurons in MTLE are mostly inactive, and are not observed in cases with local epileptiform-like activity. However, immature astroglia are present in every MTLE case and their location and activity are dependent on epileptiform-like activity. Immature astroglia, rather than newborn neurons, therefore represent a potential target to continually modulate adult human neuronal hyperactivity.


Asunto(s)
Epilepsia del Lóbulo Temporal , Epilepsia , Hipocampo , Humanos , Imagen por Resonancia Magnética , Neurogénesis , Convulsiones
14.
Epilepsia ; 52(11): e176-80, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21973215

RESUMEN

Dual-sided subdural electrodes are used in the localization and lateralization of seizure-onset zones when the area of interest is within the interhemispheric fissure. We designed the current study to test the validity of the assumption that each side of the dual-sided electrodes records from the hemisphere it faces. We recorded with dual-sided strip and grid electrodes implanted in the occipital interhemispheric space in two patients with nonoccipital epilepsy during two visual stimulation tasks in which subjects were presented with visual stimuli in the ipsilateral or contralateral visual hemifields. Our findings show substantial contamination of recordings from the opposite hemisphere. Although, as expected, electrodes recording through the falx record faintly from the contralateral cortical surface, they unexpectedly pick up strong signals from the cortex behind them. Therefore, we conclude that these electrodes should not be used for lateralization of the origin of epileptic activity or evoked responses.


Asunto(s)
Electrodos Implantados , Epilepsia/fisiopatología , Adulto , Electroencefalografía , Epilepsia/diagnóstico , Humanos , Estimulación Luminosa , Espacio Subdural , Corteza Visual/fisiopatología
15.
World Neurosurg ; 152: e32-e44, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33872837

RESUMEN

OBJECTIVE: Coherence between the hippocampus and other brain structures has been shown with the theta frequency (3-8 Hz). Cortical decreases in theta coherence are believed to reflect response accuracy efficiency. However, the role of theta coherence during conflict resolution is poorly understood in noncortical areas. In this study, coherence between the hippocampus and orbitofrontal cortex (OFC) was measured during a conflict resolution task. Although both brain areas have been previously implicated in the Stroop task, their interactions are not well understood. METHODS: Nine patients were implanted with stereotactic electroencephalography contacts in the hippocampus and OFC. Local field potential data were sampled throughout discrete phases of a Stroop task. Coherence was calculated for hippocampal and OFC contact pairs, and coherence spectrograms were constructed for congruent and incongruent conditions. Coherence changes during cue processing were identified using a nonparametric cluster-permutation t test. Group analysis was conducted to compare overall theta coherence changes among conditions. RESULTS: In 6 of 9 patients, decreased theta coherence was observed only during the incongruent condition (P < 0.05). Congruent theta coherence did not change from baseline. Group analysis showed lower theta coherence for the incongruent condition compared with the congruent condition (P < 0.05). CONCLUSIONS: Theta coherence between the hippocampus and OFC decreased during conflict. This finding supports existing theories that theta coherence desynchronization contributes to improved response accuracy and processing efficiency during conflict resolution. The underlying theta coherence observed between the hippocampus and OFC during conflict may be distinct from its previously observed role in memory.


Asunto(s)
Conflicto Psicológico , Hipocampo/fisiología , Negociación/psicología , Corteza Prefrontal/fisiología , Ritmo Teta/fisiología , Adulto , Epilepsia Refractaria/diagnóstico por imagen , Epilepsia Refractaria/psicología , Epilepsia Refractaria/cirugía , Electrodos Implantados , Electroencefalografía/métodos , Electroencefalografía/tendencias , Femenino , Hipocampo/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Corteza Prefrontal/diagnóstico por imagen , Adulto Joven
16.
J Clin Neurosci ; 91: 183-192, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34373025

RESUMEN

The amygdala is a medial temporal lobe structure known to be involved in processing emotional conflict. However, its role in processing non-emotional conflict is not well understood. Previous studies have utilized the Stroop Task to examine brain modulation of humans under the color-word conflict scenario, which is non-emotional conflict processing, and found hippocampal theta-band (4-7 Hz) modulation. This study aims to survey amygdaloid theta power changes during non-emotional conflict processing using intracranial depth electrodes in nine epileptic patients (3 female; age 20-62). All patients were asked to perform a modified Stroop task. During task performance, local field potential (LFP) data was recorded from macro contacts sampled at 2 K Hz and used for analysis. Mean theta power change from baseline was compared between the incongruent and congruent task condition groups using a paired sample t-test. Seven patients were available for analysis after artifact exclusion. In five out of seven patients, statistically significant increases in theta-band power from baseline were noted during the incongruent task condition (paired sample t-test p < 0.001), including one patient exhibiting theta power increases in both task conditions. Average response time was 1.07 s (failure trials) and 1.04 s (success trials). No speed-accuracy tradeoff was noted in this analysis. These findings indicate that human amygdaloid theta-band modulation may play a role in processing non-emotional conflict. It builds directly upon work suggesting that the amygdala processes emotional conflict and provides a neurophysiological mechanism for non-emotional conflict processing as well.


Asunto(s)
Conflicto Psicológico , Adulto , Electroencefalografía , Emociones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tiempo de Reacción , Test de Stroop , Adulto Joven
17.
J Neural Eng ; 17(6)2020 11 11.
Artículo en Inglés | MEDLINE | ID: mdl-33059331

RESUMEN

Objective. Identify the role of beta-band (13-30 Hz) power modulation in the human hippocampus during conflict processing.Approach. We investigated changes in the spectral power of the beta band (13-30 Hz) as measured by depth electrode leads in the hippocampus during a modified Stroop task in six patients with medically refractory epilepsy. Previous work done with direct electrophysiological recordings in humans has shown hippocampal theta-band (3-8 Hz) modulation during conflict processing. Local field potentials sampled at 2 k Hz were used for analysis and a non-parametric cluster-permutationt-test was used to identify the time period and frequency ranges of significant power change during cue processing (i.e. post-stimulus, pre-response).Main results. In five of the six patients, we observe a statistically significant increase in hippocampal beta-band power during successful conflict processing in the incongruent trial condition (cluster-based correction for multiple comparisons,p< 0.05). There was no significant beta-band power change observed during the cue-processing period of the congruent condition in the hippocampus of these patients.Significance. The beta-power changes during conflict processing represented here are consistent with previous studies suggesting that the hippocampus plays a role in conflict processing, but it is the first time that the beta band has been shown to be involved in humans with direct electrophysiological evidence. We propose that beta-band modulation plays a role in successful conflict detection and automatic response inhibition in the human hippocampus as studied during a conflict response task.


Asunto(s)
Epilepsia Refractaria , Electroencefalografía , Electroencefalografía/métodos , Hipocampo/fisiología , Humanos , Test de Stroop
18.
Mol Cell Neurosci ; 38(3): 431-43, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18511296

RESUMEN

BDNF signaling through its TrkB receptor plays a pivotal role in activity-dependent refinement of synaptic connectivity of retinal ganglion cells. Additionally, studies using TrkB knockout mice have suggested that BDNF/TrkB signaling is essential for the development of photoreceptors and for synaptic communication between photoreceptors and second order retinal neurons. Thus the action of BDNF on refinement of synaptic connectivity of retinal ganglion cells could be a direct effect in the inner retina, or it could be secondary to its proposed role in rod maturation and in the formation of rod to bipolar cell synaptic transmission. To address this matter we have conditionally eliminated TrkB within the retina. We find that rod function and synaptic transmission to bipolar cells is not compromised in these conditional knockout mice. Consistent with previous work, we find that inner retina neural development is regulated by retinal BDNF/TrkB signaling. Specifically we show here also that the complexity of neuronal processes of dopaminergic cells is reduced in conditional TrkB knockout mice. We conclude that retinal BDNF/TrkB signaling has its primary role in the development of inner retinal neuronal circuits, and that this action is not a secondary effect due to the loss of visual signaling in the outer retina.


Asunto(s)
Receptor trkB/fisiología , Retina/crecimiento & desarrollo , Retina/metabolismo , Animales , Factor Neurotrófico Derivado del Encéfalo/deficiencia , Factor Neurotrófico Derivado del Encéfalo/genética , Factor Neurotrófico Derivado del Encéfalo/fisiología , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Ratones Transgénicos , Red Nerviosa/crecimiento & desarrollo , Red Nerviosa/metabolismo , Receptor trkB/deficiencia , Receptor trkB/genética , Segmento Externo de la Célula en Bastón/metabolismo , Segmento Externo de la Célula en Bastón/fisiología , Transducción de Señal/genética , Transducción de Señal/fisiología
19.
J Clin Neurosci ; 63: 116-121, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30711286

RESUMEN

Somatosensory feedback is the next step in brain computer interface (BCI). Here, we compare three cortical stimulating array modalities for generating somatosensory percepts in BCI. We compared human subjects with either a 64-channel "mini"-electrocorticography grid (mECoG; 1.2-mm diameter exposed contacts with 3-mm spacing, N = 1) over the hand area of primary somatosensory cortex (S1), or a standard grid (sECoG; 1.5-mm diameter exposed contacts with 1-cm spacing, N = 1), to generate artificial somatosensation through direct electrical cortical stimulation. Finally, we reference data in the literature from a patient implanted with microelectrode arrays (MEA) placed in the S1 hand area. We compare stimulation results to assess coverage and specificity of the artificial percepts in the hand. Using the mECoG array, hand mapping revealed coverage of 41.7% of the hand area versus 100% for the sECoG array, and 18.8% for the MEA. On average, stimulation of a single electrode corresponded to sensation reported in 4.42 boxes (range 1-11 boxes) for the mECoG array, 19.11 boxes (range 4-48 boxes) for the sECoG grid, and 2.3 boxes (range 1-5 boxes) for the MEA. Sensation in any box, on average, corresponded to stimulation from 2.65 electrodes (range 1-5 electrodes) for the mECoG grid, 3.58 electrodes for the sECoG grid (range 2-4 electrodes), and 11.22 electrodes (range 2-17 electrodes) for the MEA. Based on these findings, we conclude that mECoG grids provide an excellent balance between spatial cortical coverage of the hand area of S1 and high-density resolution.


Asunto(s)
Interfaces Cerebro-Computador , Estimulación Eléctrica/métodos , Corteza Somatosensorial/fisiología , Mapeo Encefálico/métodos , Electrocorticografía/métodos , Electrodos Implantados , Mano/inervación , Humanos , Microelectrodos , Sensación
20.
J Clin Neurosci ; 64: 214-219, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31023574

RESUMEN

Previous work in directional tuning for brain machine interfaces has primarily relied on algorithm sorted neuronal action potentials in primary motor cortex. However, local field potential has been utilized to show directional tuning in macaque studies, and inferior parietal cortex has shown increased neuronal activity in reaching tasks that relied on MRI imaging. In this study we utilized local field potential recordings from a human subject performing a delayed reach task and show that high frequency band (76-100 Hz) spectral power is directionally tuned to different reaching target locations during an active reach. We also show that during the delay phase of the task, directional tuning is present in areas of the inferior parietal cortex, in particular, the supramarginal gyrus.


Asunto(s)
Potenciales de Acción/fisiología , Lóbulo Parietal/fisiología , Desempeño Psicomotor/fisiología , Adulto , Humanos , Masculino , Corteza Motora/fisiología , Neuronas/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA