Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Circ J ; 88(4): 510-516, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37438144

RESUMEN

BACKGROUND: Renal congestion is a potential prognostic factor in patients with heart failure and recently, assessment has become possible with intrarenal Doppler ultrasonography (IRD). The association between renal congestion assessed by IRD and outcomes after mitral transcatheter edge-to-edge repair (TEER) is unknown, so we aimed to clarify renal congestion and its prognostic implications in patients with mitral regurgitation (MR) who underwent TEER using MitraClip system.Methods and Results: Patients with secondary MR who underwent TEER and were assessed for intrarenal venous flow (IRVF) by IRD were classified according to their IRVF pattern as continuous or discontinuous. Of the 105 patients included, 78 patients (74%) formed the continuous group and 27 (26%) were the discontinuous group. Kaplan-Meier analysis revealed significant prognostic power of the IRVF pattern for predicting the composite outcome of all-cause death and heart failure rehospitalization (log-rank P=0.0257). On multivariate Cox regression analysis, the composite endpoint was independently associated with the discontinuous IRVF pattern (hazard ratio, 3.240; 95% confidence interval, 1.300-8.076; P=0.012) adjusted using inverse probability of treatment weighting. CONCLUSIONS: IRVF patterns strongly correlated with clinical outcomes without changes in renal function. Thus, they may be useful for risk stratification after mitral TEER for patients with secondary MR.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Angiografía , Insuficiencia Cardíaca/diagnóstico por imagen , Estimación de Kaplan-Meier , Riñón/diagnóstico por imagen , Resultado del Tratamiento
2.
Circ J ; 88(4): 531-538, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38008428

RESUMEN

BACKGROUND: The MitraClip G4 system is a new iteration of the transcatheter edge-to-edge repair system. We assessed the impact of the G4 system on routine practice and outcomes in secondary mitral regurgitation (2°MR).Methods and Results: Consecutive patients with 2°MR treated with either the MitraClip G2 (n=89) or G4 (n=63) system between 2018 and 2021 were included. Baseline characteristics, procedures, and outcomes were compared. Inverse probability of treatment weighting and Cox regression were used to adjust for baseline differences. Baseline characteristics were similar, except for a lower surgical risk in the G4 group (Society of Thoracic Surgeons Predicted Risk of Mortality ≥8: 38.1% vs. 56.2%; P=0.03). In the G4 group, more patients had short (≤2 mm) coaptation length (83.7% vs. 54.0%; P<0.001) and fewer clips were used (17.5% vs. 36.0%; P=0.02). Acceptable MR reduction was observed in nearly all patients, with no difference between the G4 and G2 groups (100% vs. 97.8%, respectively; P=0.51). The G4 group had fewer patients with high transmitral gradients (>5mmHg; 3.3% vs. 13.6%; P=0.03). At 1 year, there was no significant difference between groups in the composite endpoint (death or heart failure rehospitalization) after baseline adjustment (10.5% vs. 20.2%; hazard ratio 0.39; 95% confidence interval 0.11-1.32; P=0.13). CONCLUSIONS: The G4 system achieved comparable device outcomes to the early-generation G2, despite treating more challenging 2°MR with fewer clips.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Modelos de Riesgos Proporcionales , Cateterismo Cardíaco
3.
Eur Heart J ; 44(15): 1331-1339, 2023 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-36883599

RESUMEN

AIMS: Paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI) is associated with increased morbidity and mortality. The effect of transcatheter interventions to treat PVR after the index TAVI was investigated. METHODS AND RESULTS: A registry of consecutive patients who underwent transcatheter intervention for ≥ moderate PVR after the index TAVI at 22 centers. The principal outcomes were residual aortic regurgitation (AR) and mortality at 1 year after PVR treatment. A total of 201 patients were identified: 87 (43%) underwent redo-TAVI, 79 (39%) plug closure, and 35 (18%) balloon valvuloplasty. Median TAVI-to-re-intervention time was 207 (35; 765) days. The failed valve was self-expanding in 129 (63.9%) patients. The most frequent devices utilized were a Sapien 3 valve for redo-TAVI (55, 64%), an AVP II as plug (33, 42%), and a True balloon for valvuloplasty (20, 56%). At 30 days, AR ≥ moderate persisted in 33 (17.4%) patients: 8 (9.9%) after redo-TAVI, 18 (25.9%) after plug, and 7 (21.9%) after valvuloplasty (P = 0.036). Overall mortality was 10 (5.0%) at 30 days and 29 (14.4%) at 1 year: 0, 8 (10.1%), and 2 (5.7%) at 30 days (P = 0.010) and 11 (12.6%), 14 (17.7%), and 4 (11.4%) at 1 year (P = 0.418), after redo-TAVI, plug, and valvuloplasty, respectively. Regardless of treatment strategy, patients in whom AR was reduced to ≤ mild had lower mortality at 1 year compared with those with AR persisting ≥ moderate [11 (8.0%) vs. 6 (21.4%); P = 0.007]. CONCLUSION: This study describes the efficacy of transcatheter treatments for PVR after TAVI. Patients in whom PVR was successfully reduced had better prognosis. The selection of patients and the optimal PVR treatment modality require further investigation.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Pronóstico , Resultado del Tratamiento , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía
4.
Am Heart J ; 261: 51-54, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37011854

RESUMEN

The aim of this retrospective analysis was to investigate the prevalence and prognostic importance of incidental malignancy detected during pre-TAVI computed tomography. Among 579 patients, CT-work-up for TAVI exposed previously undetected malignancy in 4.5% of patients. TAVI patients with a new malignancy had a 2.9-fold increased risk of death at 1 year, and a 16 month shorter mean survival time compared to patients with no malignancy.


Asunto(s)
Estenosis de la Válvula Aórtica , Neoplasias , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Estudios Longitudinales , Estenosis de la Válvula Aórtica/cirugía , Estudios de Cohortes
5.
Catheter Cardiovasc Interv ; 101(1): 199-208, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36453455

RESUMEN

BACKGROUND: Elliptical shape of the aortic annulus has been associated with an increased risk of device failure after transcatheter aortic valve implantation (TAVI) compared with a circular annular shape. AIMS: To assess the impact of annulus ellipticity on procedural outcomes and device performance in patients undergoing TAVI. METHODS: In a prospective TAVI registry, aortic annulus ellipticity was assessed by preprocedural multidetector computed tomography. The annulus ratios, defined by the ratio of minimum and maximum annulus diameters measured in a transverse double oblique plane, were split into tertiles for comparisons between groups. RESULTS: A total of 1732 patients undergoing TAVI between August 2007 and June 2020 were included in the present analysis. Patients in the tertile with the most elliptical shape of the annulus were more likely to be female (59.7% vs. 47.9%; p < 0.001) and had a higher Society of Thoracic Surgeons Predicted Risk of Mortality (5.4 ± 3.8 vs. 4.8 ± 3.5; p = 0.002). There were no significant differences in the rate of technical success (95.3% vs. 96.5%; p = 0.235), device success (83.6% vs. 86.5%; p = 0.118) and intended valve performance (90.7% vs. 91.7; p = 0.503) between patients in the most elliptical tertile and the rest. However, valve dislocation/embolization occurred more frequently in patients with elliptical as compared to circular annular shape (2.6% vs. 1.2%; p = 0.046). CONCLUSIONS: Ellipticity of the aortic annulus does not affect procedural and device outcomes in patients undergoing TAVI irrespective of transcatheter heart valve design and generation. https:www.//clinicaltrials.gov. NCT01368250.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada Multidetector/métodos , Estudios Prospectivos , Resultado del Tratamiento
6.
Eur Heart J ; 43(29): 2729-2750, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35466382

RESUMEN

Transcatheter aortic valve implantation (TAVI) has matured into a standard treatment option for patients with severe symptomatic aortic valve stenosis (AS) across the whole spectrum of risk. The advances in the interventional treatment of AS raise the question of which patients with severe AS should be referred to surgery. The myriad of clinical permutations does not allow providing a single, uniform treatment strategy. Rather, the advent of TAVI along with established surgical aortic valve replacement (SAVR) fundamentally enforces the role of the multidisciplinary heart team for decision-making recommending the best individual choice of the two options based on a thorough review of clinical and anatomical factors as well as lifetime management considerations. Involvement of the informed patient expressing treatment preferences is a key for a shared decision-making process. Herein, we provide an in-depth review of evidence informing the decision-making process between TAVI and SAVR and key elements for treatment selection. Special attention is given to the populations that have been excluded from randomized clinical trials, and also lifetime management strategies of patients with severe AS are proposed.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
7.
Am Heart J ; 244: 94-106, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34788603

RESUMEN

BACKGROUND: Ascending aortic root anatomy is routinely evaluated on pre-procedural multi-detector computed tomography (MDCT). However, its clinical significance has not been adequately studied. We aimed to investigate the impact of the sinus of Valsalva (SOV) dimension on clinical outcomes in patients undergoing transcatheter aortic valve implantation (TAVI). METHODS: In a prospective TAVI registry, we retrospectively assessed SOV dimensions by pre-procedural MDCT. Patients were stratified according to tertiles of SOV diameter indexed to body surface area (SOVi). The primary endpoint was all-cause mortality at 1 year. RESULTS: Among 2066 consecutive patients undergoing TAVI between August 2007 and June 2018, 1554 patients were eligible for the present analysis. Patients in the large SOVi group were older (83 ± 6 vs 82 ± 6 vs 81 ± 6; P < .001) and had a higher Society of Thoracic Surgeons Predicted Risk of Mortality (6.3 ± 3.8 vs 5.1 ± 3.1 vs 4.9 ± 3.5; P < .001) than those in the other groups. Patients in the large SOVi group had a higher incidence of moderate or severe paravalvular regurgitation (11.9% vs 4.5% vs 3.5%; P < .001). At 1 year, a large SOVi was independently associated with an increased risk of mortality (HR: 1.62; 95% CI: 1.19-2.21; P = .002) and major or life-threatening bleeding (HR: 1.30; 95% CI: 1.02-1.65; P = .035). CONCLUSIONS: Dilatation of the aortic root at the SOV was associated with adverse outcomes after TAVI. The assessment of the aortic root should be integrated into the risk stratification system in patients undergoing TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Seno Aórtico , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Estudios Prospectivos , Estudios Retrospectivos , Seno Aórtico/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 99(6): 1908-1917, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35170846

RESUMEN

BACKGROUND: Increased left ventricular afterload resulting from severe aortic stenosis (AS) leads to progressive cardiac remodeling. Left atrial enlargement (LAE) is an early manifestation in a series of maladaptive changes and may affect clinical outcomes after valvular replacement therapy. The aim of this study is to determine the impact of LAE on clinical outcomes in symptomatic patients with severe AS undergoing transcatheter aortic valve implantation (TAVI). METHODS: In a prospective single-center TAVI registry, we analyzed LA dimensions measured by echocardiography before intervention. Patients with atrial fibrillation or concomitant mitral valve disease were excluded. LAE was defined as indexed LA volume >34 ml/m2 . The primary endpoint was cardiovascular death (CVD) at 1 year. RESULTS: Among 1663 patients undergoing TAVI between August 2007 and December 2016, 768 (46.2%) were eligible for the present analysis and 486 patients had LAE. The prevalence of LAE was higher in males (68.3%) as compared to females (58.8%). Patients with LAE were older (82.3 ± 6.7 years vs. 80.0 ± 6.4 years) and had a higher STS-PROM score (6.1 ± 4.7% vs. 4.7 ± 2.9%). After adjustment, patients with LAE had an increased risk of CVD at 1-year compared to patients with normal LA dimensions (49 [10.4%] vs. 8 [2.9%]; HRadj , 3.52; 95% CI, 1.66-7.44)]. In multivariable analysis, LAE was independently associated with an increased risk of CVD at 1-year (HRadj , 3.52; 95% CI, 1.66-7.44). CONCLUSIONS: LAE secondary to AS was documented in a significant proportion of patients undergoing TAVI and was associated with a more than threefold increased risk of CVD at 1-year.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía/métodos , Femenino , Humanos , Masculino , Estudios Prospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
9.
Catheter Cardiovasc Interv ; 100(4): 636-645, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36040717

RESUMEN

BACKGROUND: Midterm data comparing clinical outcomes after successful implantation of self-expanding and balloon-expandable transcatheter heart valves (THV) are limited. We aimed to compare 2-year outcomes after successful transcatheter aortic valve implantation (TAVI) with the Edwards balloon-expandable or the Medtronic self-expanding THV. METHODS: Two-year outcomes were analyzed according to the implanted THV in the GALILEO trial. Major adverse cardiac and cerebrovascular events (MACCE) was a composite of all-cause death or thromboembolic events including stroke, myocardial infarction, symptomatic valve thrombosis, systemic embolism, deep-vein thrombosis, or pulmonary embolism. RESULTS: Among 1644 patients recruited in 136 centers across 16 countries between 2015 and 2018, 499 received a self-expanding and 757 patients received a balloon-expandable THV. Patients treated with a self-expanding THV were more likely to be female, and had higher surgical risk, lower hemoglobin levels, and more frequent valve-in-valve procedures than those with a balloon-expandable THV. After multivariable adjustment, there were no significant differences in major clinical outcomes between self-expanding versus balloon-expandable THV: MACCE (17.0% vs. 13.4%, adjusted-hazard ratios [HR] 1.18, 95% confidence intervals [CI]: 0.82-1.69); all-cause death (11.4% vs. 9.3%, adjusted-HR 1.26; 95% CI: 0.78-2.05); cardiovascular death (8.5% vs. 4.0%, adjusted-HR 1.53; 95% CI: 0.82-2.86), any stroke (5.1% vs. 3.7%, adjusted-HR 0.86; 95% CI: 0.43-1.73); major or life-threatening bleeding (5.9% vs. 6.8%, adjusted-HR 0.93; 95% CI: 0.53-1.63). CLINICAL TRIAL REGISTRATION: https://www. CLINICALTRIALS: gov. NCT02556203. CONCLUSIONS: Two-year follow-up data from the GALILEO trial indicate that successful TAVI either with self-expanding or balloon-expandable THVs according to physician discretion did not show difference in rates of MACCE.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Femenino , Hemoglobinas , Humanos , Masculino , Diseño de Prótesis , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
10.
BMC Cardiovasc Disord ; 22(1): 178, 2022 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-35436856

RESUMEN

BACKGROUND: Computed tomography angiography (CTA) is a cornerstone in the pre- transcatheter aortic valve replacement (TAVI) assessment. We evaluated the diagnostic performance of CTA and coronary artery calcium score (CACS) for CAD evaluation compared to invasive coronary angiography in a cohort of TAVI patients. METHODS: In consecutive TAVI patients without prior coronary revascularization and device implants, CAD was assessment by quantitative analysis in CTA. (a) Patients with non-evaluable segments were classified as obstructive CAD. (b) In patients with non-evaluable segments a CACS cut-off of 100 was applied for obstructive CAD. The reference standard was quantitative invasive coronary angiography (QCA, i.e. ≥ 50% stenosis). RESULTS: 100 consecutive patients were retrospectively included, age was 82.3 ± 6.5 years and 30% of patients had CAD. In 16% of the patients, adequate visualization of the entire coronary tree (all 16 segments) was possible with CTA, while 84% had at least one segment which was not evaluable for CAD analysis due to impaired image quality. On a per-patient analysis, where patients with low image quality were classified as CAD, CTA showed a sensitivity of 100% (95% CI 88.4-100.0), specificity of 11.4% (95% CI 5.1-21.3), PPV of 32.6% (95% CI 30.8-34.5), NPV of 100% and diagnostic accuracy of 38% (95% CI 28.5-48.3) for obstructive CAD. When applying a combined approach of CTA (in patients with good image quality) and CACS (in patients with low image quality), the sensitivity and NPV remained at 100% and obstructive CAD could be ruled out in 20% of the TAVI patients, versus 8% using CTA alone. CONCLUSION: In routinely acquired pre-TAVI CTA, the image quality was insufficient in a high proportion of patients for the assessment of the entire coronary artery tree. However, when adding CACS in patients with low image quality to quantitative CTA assessment in patients with good image quality, obstructive CAD could be ruled-out in 1/5 of the patients and may therefore constitute a strategy to streamline pre-procedural workup, and reduce risk, radiation and costs in selected TAVI patients without prior coronary revascularization or device implants.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
11.
Catheter Cardiovasc Interv ; 98(5): E768-E779, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-33857355

RESUMEN

OBJECTIVES: To investigate the impact of transcatheter heart valve (THV) sizing on procedural results and clinical outcomes following transcatheter aortic valve implantation (TAVI). BACKGROUND: The impact of individual THV sizing for patients with borderline aortic annulus anatomy remains unclear. METHODS: In the prospective BernTAVI registry, THV sizing conditions were retrospectively evaluated, and patients were categorized into three groups based on the recommendations and the sizing chart of the manufacturers: optimal sizing, borderline sizing (THV size located within 5% to each border of the optimal sizing recommendation), and suboptimal sizing (THV size outside the recommended range). The latter two groups were further subcategorized into THV-oversizing and THV-undersizing. The primary endpoint was a composite of all-cause death and unplanned repeat intervention at 1 year. RESULTS: Out of a total of 1,638 patients who underwent TAVI, 9.5 and 15.6% of patients were categorized into the borderline and suboptimal sizing group, respectively. Device success was achieved in 87.4, 88.9, and 83.6% of patients with optimal, borderline, and suboptimal sizing, respectively. The primary endpoint occurred in 12.3% of patients with optimal sizing, 14.9% of patients with borderline sizing (HRadj 1.35, 95%CI 0.87-2.09), and in 17.4% of patients with suboptimal sizing (HRadj 1.42, 95%CI 1.01-1.99). Within the suboptimal sizing cohort, unfavorable outcomes were mainly associated with THV undersizing (device success: 76.4%, primary endpoint: 23.9%, HRadj 1.98, 95%CI 1.36-2.87). CONCLUSION: Suboptimal TAVI prosthesis sizing is associated with an increased risk of all-cause death and unplanned repeat intervention within 1 year largely attributable to undersized THV prostheses.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Tomografía Computarizada Multidetector , Estudios Prospectivos , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
12.
Catheter Cardiovasc Interv ; 98(7): 1404-1412, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34406713

RESUMEN

OBJECTIVES: To investigate whether the integrative echocardiographic criteria used in the cardiovascular outcomes assessment of the mitraclip percutaneous therapy (COAPT) for heart failure patients with functional mitral regurgitation study predict outcomes after edge-to-edge trancatheter mitral valve repair (TMVr) for the treatment of secondary mitral regurgitation (SMR). BACKGROUND: Two randomized controlled trials comparing TMVr to medical treatment reported conflicting findings. Differences in patient selection criteria may have contributed to these diverging results. METHODS: Patients undergoing TMVr were stratified following the integrative COAPT echocardiographic criteria in noneligible and eligible patients who were further classified into three tiers according to effective regurgitant orifice (EROA) (Tier 1: EROA ≥ 0.3cm2 ; Tier 2: EROA 0.2cm2 and 0.29cm2 ; Tier 3: EROA<0.2cm2 ) combined with several other severity criteria. We assessed between group differences in all-cause mortality, successful SMR reduction, and symptom relief from baseline to 2-year follow-up. RESULTS: Between March 2011 and March 2018, 138 patients (mean age 75 years) satisfying the inclusion criteria underwent TMVr for treatment of symptomatic SMR. The mean EROA area was 0.35 ± 0.17 mm2 . Ten patients (7%) died within 30 days, 29 (21%) within 12 months, and 41 (30%) within 2 years. After stratification according to the COAPT echocardiographic criteria that were fulfilled in 72% of the studied population, Tier 2 patients (45%), as well as noneligible patients (38%) had a higher mortality rate compared to those in Tier 1 (19%). CONCLUSIONS: SMR patients stratified into tiers according to the COAPT integrative echocardiographic criteria have diverging prognostic and symptomatic benefit after edge-to-edge TMVr.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Cateterismo Cardíaco/efectos adversos , Ecocardiografía , Insuficiencia Cardíaca/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
13.
Curr Cardiol Rep ; 22(10): 107, 2020 08 08.
Artículo en Inglés | MEDLINE | ID: mdl-32770431

RESUMEN

PURPOSE OF REVIEW: Critical appraisal of the available evidence on the self-expanding ACURATE neo transcatheter heart valve (THV) for the treatment of aortic valve disease. RECENT FINDINGS: In an investigator-initiated, multicenter, randomized non-inferiority trial with broad inclusion criteria, ACURATE neo failed to meet non-inferiority compared with SAPIEN 3 with regard to a primary composite safety and efficacy endpoint at 30 days. The difference was driven by higher rates of moderate or severe paravalvular regurgitation and higher rates of acute kidney injury. In turn, registry data suggest that the safety and efficacy profile of the ACURATE neo is comparable to that of other commercially available devices. Randomized evidence indicated favorable hemodynamic results with large effective orifice areas and low residual gradients. The self-expanding ACURATE neo THV is associated with higher rates of residual aortic regurgitation compared to the balloon-expandable SAPIEN 3 THV. The supra-annular design with low residual gradients may be advantageous in patients with small anatomy and mild degree of calcification.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Estudios Multicéntricos como Asunto , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Resultado del Tratamiento
15.
Circ J ; 83(5): 1054-1063, 2019 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-30930346

RESUMEN

BACKGROUND: Beta-blockers are standard therapy for acute myocardial infarction (AMI). However, despite current advances in the management of AMI, it remains unclear whether all AMI patients benefit from ß-blockers. We investigated whether admission heart rate (HR) is a determinant of the effectiveness of ß-blockers for AMI patients. Methods and Results: We enrolled 3,283 consecutive AMI patients who were admitted to 28 participating institutions in the Japanese Registry of Acute Myocardial Infarction Diagnosed by Universal Definition (J-MINUET) study. According to admission HR, we divided patients into 3 groups: bradycardia (HR <60 beats/min, n=444), normocardia (HR 60 to ≤100 beats/min, n=2,013), and tachycardia (HR >100 beats/min, n=342). The primary endpoint was major adverse cardiac events (MACE), including all-cause death, non-fatal MI, non-fatal stroke, heart failure (HF), and urgent revascularization for unstable angina, at 3-year follow-up. Beta-blocker at discharge was significantly associated with a lower risk of MACE in the tachycardia group (23.6% vs. 33.0%; P=0.033), but it did not affect rates of MACE in the normocardia group (17.8% vs. 18.4%; P=0.681). In the bradycardia group, ß-blocker use at discharge was significantly associated with a higher risk of MACE (21.6% vs. 12.7%; P=0.026). Results were consistent for multivariable regression and stepwise multivariable regression. CONCLUSIONS: Admission HR might determine the efficacy of ß-blockers for current AMI patients.


Asunto(s)
Antagonistas Adrenérgicos beta/administración & dosificación , Frecuencia Cardíaca , Infarto del Miocardio/tratamiento farmacológico , Infarto del Miocardio/mortalidad , Admisión del Paciente , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad
16.
Heart Vessels ; 34(12): 1899-1908, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31129873

RESUMEN

It is known that incidence and short-term mortality rate of acute myocardial infarction (AMI) tend to be higher in the cold season. The aim of our study was to investigate the association of onset-season with patient characteristics and long-term prognosis of AMI. This was a prospective, multicenter, Japanese investigation of 3,283 patients with AMI who were hospitalized within 48 h of symptom onset between July 2012 and March 2014. Patients were divided into 3 seasonal groups according to admission date: cold season group (December-March), hot season group (June-September), and moderate season group (April, May, October, and November). We identified 1356 patients (41.3%) admitted during the cold season, 901 (27.4%) during the hot season, and 1026 (31.3%) during the moderate season. We investigated the seasonal effect on patient characteristics and clinical outcomes. Baseline characteristics of each seasonal group were comparable, with the exception of age, Killip class, and conduction disturbances. The rates of higher Killip class and complete atrioventricular block were significantly higher in the cold season group. The 3-year cumulative survival free from major adverse cardiac events (MACE) rate was the lowest in the cold season (67.1%), showing a significant difference, followed by the moderate (70.0%) and hot seasons (72.9%) (p < 0.01). Initial severity and long-term prognoses were worse in patients admitted during the cold season. Our findings highlight the importance of optimal prevention and follow-up of AMI patients with cold season onset.


Asunto(s)
Infarto del Miocardio/epidemiología , Sistema de Registros , Medición de Riesgo/métodos , Estaciones del Año , Anciano , Femenino , Estudios de Seguimiento , Mortalidad Hospitalaria/tendencias , Humanos , Incidencia , Japón/epidemiología , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Pronóstico , Estudios Prospectivos , Factores de Riesgo , Factores de Tiempo
17.
Circ J ; 82(12): 3082-3089, 2018 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-30298852

RESUMEN

BACKGROUND: Obesity has previously been identified as an indicator of good prognosis in patients undergoing transcatheter aortic valve implantation (TAVI), an association known as the "obesity paradox". We investigated whether abdominal total fat area (TFA), visceral fat area (VFA), or subcutaneous fat area (SFA) are prognostic indicators of long-term clinical outcome in patients undergoing TAVI. Methods and Results: We retrospectively analyzed 100 consecutive patients who underwent TAVI between December 2013 and April 2017. TFA, VFA, and SFA were measured from routine pre-procedural computed tomography (CT). Patients were divided into 2 groups according to median TFA, VFA, or SFA, and we investigated the association of abdominal fat area with adverse clinical events, including all-cause death and re-hospitalization due to worsening heart failure. At a median follow-up of 665 days, patients with higher SFA had significantly lower incidence of the composite outcome and all-cause death compared with patients with lower SFA (15.0% vs. 37.7%, P=0.025; and 8.9% vs. 23.7%, P=0.047, respectively). In contrast, patients with higher TFA or VFA did not show significant reduction in the incidences of the composite outcome or all-cause mortality. CONCLUSIONS: CT-derived SFA had prognostic value in patients undergoing TAVI.


Asunto(s)
Grasa Abdominal/diagnóstico por imagen , Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Estudios Retrospectivos , Tasa de Supervivencia
19.
Cardiovasc Revasc Med ; 58: 68-76, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37500393

RESUMEN

BACKGROUND: Aortic stenosis (AS) and chronic kidney disease (CKD) can coexist. Repeat exposure to contrast media in patients undergoing transcatheter aortic valve implantation (TAVI) has latent mortality risks and increased risk for acute kidney injury. We aimed to assess our "zero-contrast TAVI" protocol for patients with advanced CKD. METHODS: Consecutive patients with severe AS who underwent TAVI at a single center registry were enrolled. Zero-contrast TAVI group included patients who underwent TAVI without contrast and who had an estimated glomerular filtration rate <30 mL/min/1.73 m2. Conventional TAVI group included patients who underwent the regular TAVI procedure. Patients using balloon-expandable valves via transfemoral approach were analyzed. Baseline clinical and procedural characteristics and clinical outcomes were compared between two groups. The primary outcome was early safety as defined by Valve Academic Research Consortium Criteria. Secondary outcomes included the presence of severe prosthesis-patient mismatch, moderate or greater perivalvular leakage, and requirement for new dialysis (within 3 months). RESULTS: A total of 520 patients were analyzed. Among these, 32 (6 %) underwent zero-contrast TAVI and 488 (94 %) conventional TAVI. In the zero-contrast TAVI group, 12 patients (37.5 %) had to use 20.7 (11.0-31.2) mL of contrast media. There were no significant differences in the primary and secondary outcomes between zero-contrast TAVI and conventional TAVI groups (78.1 % vs. 86.8 %, P = 0.184 and 9.4 % vs. 8.1 %, P = 0.738 for the primary and secondary outcomes, respectively). CONCLUSIONS: Zero-contrast TAVI is feasible, safe, and effective in patients with AS and stage 4 CKD.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estudios de Factibilidad , Medios de Contraste/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/terapia , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento
20.
Cardiovasc Interv Ther ; 39(1): 74-82, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37938532

RESUMEN

The safety and feasibility are still not well known for exercise-induced mitral regurgitation (MR). This study is aimed to assess and compare the hemodynamic and symptomatic changes in patients with significant secondary MR during exercise stress echocardiography (ESE) before and after transcatheter edge-to-edge repair (TEER). The study included a total of 15 patients with secondary MR who underwent ESE before and after TEER using the MitraClip system (Abbott, Abbott Park, IL, USA). Echocardiographic data of ESE were collected both before the procedure and during the follow-up visit at 3 months. During the one-year postoperative observation period, the rate of readmission due to heart failure was 13% (n = 2), with no recorded fatalities. Although no significant differences of ESE data were observed in exercise-induced pulmonary hypertension or cardiac output before and after the repair, the severity of MR was significantly improved after the procedure, both at rest (2 [2-3] vs. 1 [1-2], p = 0.0125) and during ESE (3 [3-3] vs. 1 [1-1], p < 0.0001). Furthermore, the New York Heart Association Functional Classification was improved (3 [3-3] vs. 1 [1-1], p < 0.0001) after treatment. For a supplemental analysis, MR during ESE was significantly improved not only in cases with atrial secondary MR but also in ventricular secondary MR. Transcatheter edge-to-edge repair for exercise-induced MR resulted in a significant improvement in postoperative MR severity and subjective symptoms. These results are novel, as they have not been extensively reported previously, particularly among Japanese patients.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Ecocardiografía de Estrés , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/cirugía , Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA