Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Clin Chem Lab Med ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38726708

RESUMEN

In recent years, the integration of technological advancements and digitalization into healthcare has brought about a remarkable transformation in care delivery and patient management. Among these advancements, the concept of digital twins (DTs) has recently gained attention as a tool with substantial transformative potential in different clinical contexts. DTs are virtual representations of a physical entity (e.g., a patient or an organ) or systems (e.g., hospital wards, including laboratories), continuously updated with real-time data to mirror its real-world counterpart. DTs can be utilized to monitor and customize health care by simulating an individual's health status based on information from wearables, medical devices, diagnostic tests, and electronic health records. In addition, DTs can be used to define personalized treatment plans. In this study, we focused on some possible applications of DTs in laboratory medicine when used with AI and synthetic data obtained by generative AI. The first point discussed how biological variation (BV) application could be tailored to individuals, considering population-derived BV data on laboratory parameters and circadian or ultradian variations. Another application could be enhancing the interpretation of tumor markers in advanced cancer therapy and treatments. Furthermore, DTs applications might derive personalized reference intervals, also considering BV data or they can be used to improve test results interpretation. DT's widespread adoption in healthcare is not imminent, but it is not far off. This technology will likely offer innovative and definitive solutions for dynamically evaluating treatments and more precise diagnoses for personalized medicine.

2.
Clin Chem Lab Med ; 62(5): 835-843, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38019961

RESUMEN

BACKGROUND: In the rapid evolving landscape of artificial intelligence (AI), scientific publishing is experiencing significant transformations. AI tools, while offering unparalleled efficiencies in paper drafting and peer review, also introduce notable ethical concerns. CONTENT: This study delineates AI's dual role in scientific publishing: as a co-creator in the writing and review of scientific papers and as an ethical challenge. We first explore the potential of AI as an enhancer of efficiency, efficacy, and quality in creating scientific papers. A critical assessment follows, evaluating the risks vs. rewards for researchers, especially those early in their careers, emphasizing the need to maintain a balance between AI's capabilities and fostering independent reasoning and creativity. Subsequently, we delve into the ethical dilemmas of AI's involvement, particularly concerning originality, plagiarism, and preserving the genuine essence of scientific discourse. The evolving dynamics further highlight an overlooked aspect: the inadequate recognition of human reviewers in the academic community. With the increasing volume of scientific literature, tangible metrics and incentives for reviewers are proposed as essential to ensure a balanced academic environment. SUMMARY: AI's incorporation in scientific publishing is promising yet comes with significant ethical and operational challenges. The role of human reviewers is accentuated, ensuring authenticity in an AI-influenced environment. OUTLOOK: As the scientific community treads the path of AI integration, a balanced symbiosis between AI's efficiency and human discernment is pivotal. Emphasizing human expertise, while exploit artificial intelligence responsibly, will determine the trajectory of an ethically sound and efficient AI-augmented future in scientific publishing.


Asunto(s)
Inteligencia Artificial , Edición , Humanos , Benchmarking , Investigadores
3.
Clin Chem Lab Med ; 62(4): 635-645, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37982680

RESUMEN

OBJECTIVES: Patient-based real-time quality control (PBRTQC), a laboratory tool for monitoring the performance of the testing process, has gained increasing attention in recent years. It has been questioned for its generalizability among analytes, instruments, laboratories, and hospitals in real-world settings. Our purpose was to build a machine learning, nonlinear regression-adjusted, patient-based real-time quality control (mNL-PBRTQC) with wide application. METHODS: Using computer simulation, artificial biases were added to patient population data of 10 measurands. An mNL-PBRTQC was created using eight hospital laboratory databases as a training set and validated by three other hospitals' independent patient datasets. Three different Patient-based models were compared on these datasets, the IFCC PBRTQC model, linear regression-adjusted real-time quality control (L-RARTQC), and the mNL-PBRTQC model. RESULTS: Our study showed that in the three independent test data sets, mNL-PBRTQC outperformed the IFCC PBRTQC and L-RARTQC for all measurands and all biases. Using platelets as an example, it was found that for 20 % bias, both positive and negative, the uncertainty of error detection for mNL-PBRTQC was smallest at the median and maximum values. CONCLUSIONS: mNL-PBRTQC is a robust machine learning framework, allowing accurate error detection, especially for analytes that demonstrate instability and for detecting small biases.


Asunto(s)
Aprendizaje Automático , Humanos , Simulación por Computador , Control de Calidad
4.
Clin Chem Lab Med ; 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38721806

RESUMEN

OBJECTIVES: There is a growing interest in the relevance of salivary cortisol and cortisone concentrations in stress-related research. To correctly attribute the magnitude of salivary cortisol and cortisone variation as an effect of a stressful event, a coherent understanding of the day-to-day intra-individual and inter-individual variability across the diurnal cycle of the two steroids is required. However, such information is currently lacking. METHODS: This study aimed to overcome these existing limitations by performing an investigation of the biological variation (BV) of salivary cortisol and cortisone within one day and between five days using an LC-MS/MS method. Saliva samples were collected from 20 healthy volunteers immediately after waking up, at 8:00, 12:00, 15:00, 19:00 and 23:00 on each day over five days. All samples were analyzed in duplicate in one run. Nested ANOVA was used to calculate the sums of squares for analytical and biological components of variation. RESULTS: The within-subject BV of salivary cortisol and cortisone (CVI) ranged from a minimum of 29.3 and 19.0 % to a maximum of 56.5 and 49.1 %, respectively, while the between-subject biological variation (CVG) ranged from 29.7 and 29.0 % to 51.6 and 43.6 %. The reference change values (RCVs) ranged from 96 to 245 % for cortisol and from 55 to 194 % for cortisone. A medium index of individuality was observed for both compounds at all time points. CONCLUSIONS: This study provides updated BV estimates and RCVs for different times of day that can be used to assess the magnitude of change in biomarkers in future stress-related research.

5.
Clin Chem Lab Med ; 62(3): 572-577, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-37787733

RESUMEN

OBJECTIVES: In this study, we describe the analytical and clinical performances of the SNIBE Maglumi SARS-CoV-2 antigen fully-automated chemiluminescent immunoassay (MAG-CLIA) on salivary samples. METHODS: Limit of detection (LOD), linearity and precision were tested for values close to or below the declared LOD. Clinical performance of MAG-CLIA was evaluated on leftover salivary samples from the healthcare workers (HCW) surveillance program, at the University-Hospital of Padova. Salivary samples were analyzed by Lumipulse G SARS-CoV-2 Ag, and in case where the values exceeded 0.41 ng/L, further testing was conducted using TaqPathTM COVID-19 RT-PCR (Applied Biosystems, Thermo Fisher Scientific). RESULTS: The estimated MAG-CLIA LOD was 3 ng/L, with repeatability of 7.5 %. Good linearity was demonstrated by diluting two samples at 52.7 ng/L and 211.4 ng/L. Of the 228 HCW samples, 59/228 (25.9 %) were positive, 169/228 (74.1 %) were negative. MAG-CLIA SARS-CoV-2 sAg median level (and interquartile range [IQR]) was 5.03 ng/L (<0.001-35.8 ng/L) for positive and <0.001 ng/L (<0.001 ng/L) for negative samples. MAG-CLIA AUC was 0.795 (95 % CI: 0.720-0.871). Using the best cut-off, 3.5 ng/L, sensitivity and specificity were 57.1 % (95 % CI: 42.2-71.2 %) and 97.0 % (95 % CI: 93.2-99.0 %), respectively. The agreement with the molecular assay was 88.1 % (Cohen's kappa 0.606 [SE=0.066, p<0.001]). CONCLUSIONS: The analytical performances of MAG-CLIA are satisfactory, also when values below LOD were tested. In saliva samples, although specificity was elevated, clinical performance was not comparable with that on nasopharyngeal swabs (NPS).


Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Pruebas Inmunológicas , Antígenos Virales , Bioensayo , Sensibilidad y Especificidad
6.
Clin Chem Lab Med ; 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38880779

RESUMEN

Point-of-care testing (POCT) is becoming an increasingly popular way to perform laboratory tests closer to the patient. This option has several recognized advantages, such as accessibility, portability, speed, convenience, ease of use, ever-growing test panels, lower cumulative healthcare costs when used within appropriate clinical pathways, better patient empowerment and engagement, and reduction of certain pre-analytical errors, especially those related to specimen transportation. On the other hand, POCT also poses some limitations and risks, namely the risk of lower accuracy and reliability compared to traditional laboratory tests, quality control and connectivity issues, high dependence on operators (with varying levels of expertise or training), challenges related to patient data management, higher costs per individual test, regulatory and compliance issues such as the need for appropriate validation prior to clinical use (especially for rapid diagnostic tests; RDTs), as well as additional preanalytical sources of error that may remain undetected in this type of testing, which is usually based on whole blood samples (i.e., presence of interfering substances, clotting, hemolysis, etc.). There is no doubt that POCT is a breakthrough innovation in laboratory medicine, but the discussion on its appropriate use requires further debate and initiatives. This collective opinion paper, composed of abstracts of the lectures presented at the two-day expert meeting "Point-Of-Care-Testing: State of the Art and Perspective" (Venice, April 4-5, 2024), aims to provide a thoughtful overview of the state-of-the-art in POCT, its current applications, advantages and potential limitations, as well as some interesting reflections on the future perspectives of this particular field of laboratory medicine.

7.
Artículo en Inglés | MEDLINE | ID: mdl-38606530

RESUMEN

OBJECTIVES: Establishing direct reference intervals (RIs) for paediatric patients is a very challenging endeavour. Indirect RIs can address this problem, using existing clinical laboratory databases from real-world data research. Compared to the traditional direct method, the indirect approach is highly practical, widely applicable, and low-cost. Considering the relevance of dyslipidemia in the paediatric age, to provide better laboratory services to the local paediatric population, we established population-specific lipid RIs via data mining. METHODS: Our laboratory information system was searched for cholesterol (TC), triglycerides (TG), low-density lipoprotein (LDL) and high-density lipoprotein (HDL) of patients aged less than 18 years, performed from January 2009 until December 2022. RIs were estimated using RefineR algorithm. RESULTS: Values from 215,594 patients were initially collected. After refining data on the basis of specific exclusion criteria that left 17,933 patients, we determined the RIs for each analyte, including corresponding 95% confidence interval (95% CI). Age and sex partitions were required for proper stratification of the heterogenous subpopulations. Age-related variations in TC and TG values were observed mainly in children until 5 years. RIs were defined for children less than 3 years and for those of 3-18 years. In our population, the obtained RIs were comparable with those of the literature, but the upper TG limit in subjects under the age of 3 (2.03 mmol/L with 95% CI: 1.45-2.86) was lower than that previously reported. CONCLUSIONS: Our RIs, necessary for paediatric lipid monitoring, are tailored to the serviced patient population as should be done whenever possible.

8.
Curr Issues Mol Biol ; 45(7): 5534-5557, 2023 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-37504266

RESUMEN

In this review, the role of innate and adaptive immunity in the pathogenesis of inflammatory bowel diseases (IBD) is reported. In IBD, an altered innate immunity is often found, with increased Th17 and decreased Treg cells infiltrating the intestinal mucosa. An associated increase in inflammatory cytokines, such as IL-1 and TNF-α, and a decrease in anti-inflammatory cytokines, such as IL-10, concur in favoring the persistent inflammation of the gut mucosa. Autoinflammation is highlighted with insights in the role of inflammasomes, which activation by exogenous or endogenous triggers might be favored by mutations of NOD and NLRP proteins. Autoimmunity mechanisms also take place in IBD pathogenesis and in this context of a persistent immune stimulation by bacterial antigens and antigens derived from intestinal cells degradation, the adaptive immune response takes place and results in antibodies and autoantibodies production, a frequent finding in these diseases. Inflammation, autoinflammation and autoimmunity concur in altering the mucus layer and enhancing intestinal permeability, which sustains the vicious cycle of further mucosal inflammation.

9.
Clin Chem Lab Med ; 61(4): 688-695, 2023 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-36660807

RESUMEN

In the last few decades, quality in laboratory medicine has evolved in concert with the transformation and the changes (technological, scientific and organizational) in this sector. Laboratory professionals have faced great challenges, at times being overwhelmed, yet also involved in this progress. Worldwide, laboratory professionals and scientific societies involved in laboratory medicine have raised awareness concerning the need to identify new quality assurance tools that are effective in reducing the error rate and enhancing patient safety, in addition to Internal Quality Control (IQC) procedures and the participation in the External Quality Assessment Schemes (EQAS). The use of Quality Indicators (QIs), specifically designed for laboratory medicine are effective in assessing and monitoring all critical events occurring in the different phases of Total Testing Process (TTP), in particular, in the extra-analytical phases. The Model of Quality Indicators (MQI), proposed by the Working Group "Laboratory Errors and Patient Safety" (WG-LEPS) of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and validated by experts in consensus conferences, is an important window of opportunity for the medical laboratory to demonstrate the use of an effective quality assurance tool fit for this purpose. Aim of this paper is to provide an update of the state-of-the-art concerning the most used QIs data collected in 2021 and the Quality Specifications (QSs) proposed for their evaluation. Moreover, a strategy for the future is proposed in order to improve the MQI and encourage its use in medical laboratories throughout the world.


Asunto(s)
Laboratorios , Indicadores de Calidad de la Atención de Salud , Humanos , Seguridad del Paciente , Control de Calidad , Exactitud de los Datos , Técnicas de Laboratorio Clínico
10.
Clin Chem Lab Med ; 61(9): 1652-1660, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-36957995

RESUMEN

OBJECTIVES: The SARS-CoV-2 immune response is mediated by both humoral and cellular immunity. In this study, SARS-CoV-2 specific cellular immunity was tested by a novel direct real-time PCR (dRT-PCR) assay, targeting mRNA of CXCL10, and compared with respect to an ELISA measuring interferon gamma (IFN-γ) release. METHODS: Whole blood (Li-He) and serum samples were collected from 92 healthcare workers (HCW), with three doses of homologous (Pfizer/BioNTech, n=74) or heterologous (Pfizer/BioNTech and Vaxzevria or Moderna, n=18) vaccinations. Li-He samples were incubated with SCV2 PANEL-1-T-ACTIVATION (Hyris srl, Lodi, Italy), or CoV-2 IGRA TUBE ELISA (Euroimmune, Lubeck, Germany). CXCL10 mRNA expression was analyzed by bCube/bApp (Hyris), while IFN-γ was evaluated by quant-T-Cell SARS-CoV-2 ELISA (Euroimmune). Anti-SARS-CoV-2 S-RBD IgG levels were measured in sera using a CLIA assay (Snibe, Shenzen, China). RESULTS: Imprecision of dRT-PCR assay was found to be satisfactory, and the two methods for measuring T cell immunity to SARS-CoV-2 peptides agreed in 82/87 (94.2%) of results. At qualitative dRT-PCR analyses, 81 subjects (93.2%) resulted as reactive to SARS-CoV-2 peptides, 3 (3.4%) were borderline and 3 were negative (3.4%). At univariate and multivariate analyses of quantitative dRT-PCR mRNA of CXCL10 and IFN-γ release results showed no difference between HCW with previous infection, homologous/heterologous vaccination, or demographical features. Anti-SARS-CoV-2 S-RBD IgG was associated with the previous infection and the time between the last vaccination or positivity. CONCLUSIONS: Direct RT-PCR appeared accurate for determining the presence or absence of immunoreactivity of SARS-CoV-2 specific T cells, especially when rapid analyses are required, such as for organ transplantation.


Asunto(s)
COVID-19 , Linfocitos T , Humanos , Vacunas contra la COVID-19 , Reacción en Cadena en Tiempo Real de la Polimerasa , COVID-19/diagnóstico , COVID-19/prevención & control , SARS-CoV-2 , Vacunación , Litio , Inmunoglobulina G , Anticuerpos Antivirales , Prueba de COVID-19
11.
Clin Chem Lab Med ; 61(2): 311-315, 2023 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-36282964

RESUMEN

OBEJCTIVES: Serosurveys can be used to monitor COVID-19 seroprevalence and conduct surveillance. Dried blood spot (DBS), used increasingly as a valuable sample to assay severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) antibodies (Ab), has several advantages, particularly in infants, due to the limited amount of blood required and its utility in testing a large number of samples in a limited time-frame. We evaluated SARS-CoV-2 IgG Ab prevalence in newborn DBS in the Trentino region of Italy, during the time period January 2020 - December 2021. METHODS: Anti-SARS-CoV-2 IgG levels were determined in DBS by means of Anti-SARS-CoV-2 QuantiVac IgG ELISA assay (Euroimmun, Lubeck, Germany). RESULTS: Analyses included 2,400 DBS from newborns (54% M, 46% F), samples being collected 2-3 days after birth. The first DBS that tested positive for anti-SARS-CoV-2 IgG antibodies was found in March 2020 and, up to May 2020, only 4 positive results were detected overall. Starting from June 2020, the positivity thresholds increased according to the epidemiological waves of the COVID-19 pandemic in Italy, with a robust increment in the winters of 2020 and 2021. The percentage of positive DBS rose from 0 to 6% to 10-47%, in 2020 and 2021, respectively. CONCLUSIONS: This study demonstrates DBS is a suitable tool for both epidemiological purposes and surveillance in the SARS-CoV-2 pandemic, particularly in newborns and pregnant women, saving blood waste and sparing patients any discomfort.


Asunto(s)
COVID-19 , Pandemias , Embarazo , Humanos , Recién Nacido , Femenino , Estudios Seroepidemiológicos , SARS-CoV-2 , COVID-19/diagnóstico , COVID-19/epidemiología , Anticuerpos Antivirales , Inmunoglobulina G
12.
Clin Chem Lab Med ; 61(2): 323-331, 2023 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-36282616

RESUMEN

OBJECTIVES: The rapid, accurate and safe detection of SARS-CoV-2 is the key to improving surveillance and infection containment. The aim of the present study was to ascertain whether, after heat/chemical inactivation, SARS-CoV-2 N antigen chemiluminescence (CLEIA) assay in saliva remains a valid alternative to molecular testing. METHODS: In 2022, 139 COVID-19 inpatients and 467 healthcare workers were enrolled. In 606 self-collected saliva samples (Salivette), SARS-CoV-2 was detected by molecular (TaqPath rRT-PCR) and chemiluminescent Ag assays (Lumipulse G). The effect of sample pre-treatment (extraction solution-ES or heating) on antigen recovery was verified. RESULTS: Salivary SARS-CoV-2 antigen assay was highly accurate (AUC=0.959, 95% CI: 0.943-0.974), with 90% sensitivity and 92% specificity. Of the 254 antigen positive samples, 29 were false positives. We demonstrated that heterophilic antibodies could be a cause of false positive results. A significant antigen concentration decrease was observed after ES treatment (p=0.0026), with misclassification of 43 samples. Heat had a minimal impact, after treatment the correct classification of cases was maintained. CONCLUSIONS: CLEIA SARS-CoV-2 salivary antigen provides accurate, timely and high-throughput results that remain accurate also after heat inactivation, thus ensuring a safer work environment. This supports the use of salivary antigen detection by CLEIA in surveillance programs.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Prueba de COVID-19 , Saliva , Sensibilidad y Especificidad
13.
Clin Chem Lab Med ; 61(10): 1802-1807, 2023 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-37114858

RESUMEN

OBJECTIVES: Antibodies against glutamic acid decarboxylase isoform 65 (GAD-Ab) have been found in different severe neurological conditions associated with altered synthesis of γ-aminobutyric acid (GABA). Serum GAD-Ab can be found in up to 90 % of patients with type 1 diabetes mellitus (T1DM), mostly at relatively low concentrations, while high concentrations of GAD-ab are thought to be more frequently associate to a neurological condition, with levels 100-folds higher than those found in T1DM. Although CSF testing is recommended when suspecting a GAD-associated neurological syndrome, no commercial immunoassay is validated for this use and no cut-off is internationally recognized to support the diagnosis. METHODS: In this study we validated CSF testing of GAD-Ab on an automated chemiluminescence (CLIA) immunoassay that had previously shown good agreement with ELISA on serum. RESULTS: We tested 43 CSF from patients with typical GAD-associated neurological disorders and patients with other neurological conditions, identifying a clinical cut-off of 18 kIU/L that discriminated GAD-disease with an area under the curve (AUC) of 0.921. CLIA showed good analytical performances on repeatability and recovery tests in CSF and confirmed an excellent agreement with ELISA. CONCLUSIONS: GAD-Ab associated neurological disorders are rare but CSF testing for GAD-Ab is a common request for neurologists when suspecting an insidious autoimmune central nervous system disease. CLIA platforms are expected to be increasingly adopted in clinical laboratories due to their flexibility and reliability, therefore studies on decisional levels should be implemented for improving the interpretation and utilization of laboratory data.


Asunto(s)
Diabetes Mellitus Tipo 1 , Enfermedades del Sistema Nervioso , Humanos , Autoanticuerpos , Síndrome , Diabetes Mellitus Tipo 1/diagnóstico , Luminiscencia , Reproducibilidad de los Resultados , Enfermedades del Sistema Nervioso/diagnóstico , Glutamato Descarboxilasa
14.
Clin Chem Lab Med ; 61(7): 1158-1166, 2023 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-37083166

RESUMEN

OBJECTIVES: ChatGPT, a tool based on natural language processing (NLP), is on everyone's mind, and several potential applications in healthcare have been already proposed. However, since the ability of this tool to interpret laboratory test results has not yet been tested, the EFLM Working group on Artificial Intelligence (WG-AI) has set itself the task of closing this gap with a systematic approach. METHODS: WG-AI members generated 10 simulated laboratory reports of common parameters, which were then passed to ChatGPT for interpretation, according to reference intervals (RI) and units, using an optimized prompt. The results were subsequently evaluated independently by all WG-AI members with respect to relevance, correctness, helpfulness and safety. RESULTS: ChatGPT recognized all laboratory tests, it could detect if they deviated from the RI and gave a test-by-test as well as an overall interpretation. The interpretations were rather superficial, not always correct, and, only in some cases, judged coherently. The magnitude of the deviation from the RI seldom plays a role in the interpretation of laboratory tests, and artificial intelligence (AI) did not make any meaningful suggestion regarding follow-up diagnostics or further procedures in general. CONCLUSIONS: ChatGPT in its current form, being not specifically trained on medical data or laboratory data in particular, may only be considered a tool capable of interpreting a laboratory report on a test-by-test basis at best, but not on the interpretation of an overall diagnostic picture. Future generations of similar AIs with medical ground truth training data might surely revolutionize current processes in healthcare, despite this implementation is not ready yet.


Asunto(s)
Inteligencia Artificial , Química Clínica , Humanos , Laboratorios
15.
Int J Mol Sci ; 24(16)2023 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-37628976

RESUMEN

Studies investigating the potential role of circulating bile acids (BAs) as diagnostic biomarkers for cholangiocarcinoma (CCA) are sparse and existing data do not adjust for confounding variables. Furthermore, the mechanism by which BAs affect the expression of the oncogenic mucin 5AC (MUC5AC) has never been investigated. We performed a case-control study to characterise the profile of circulating BAs in patients with CCA (n = 68) and benign biliary disease (BBD, n = 48) with a validated liquid chromatography-tandem mass spectrometry technique. Odd ratios (OR) for CCA associations were calculated with multivariable logistic regression models based on a directed acyclic graph structure learning algorithm. The most promising BAs were then tested in an in vitro study to investigate their interplay in modulating MUC5AC expression. The total concentration of BAs was markedly higher in patients with CCA compared with BBD controls and accompanied by a shift in BAs profile toward a higher proportion of primary conjugated BAs (OR = 1.50, CI: 1.14 to 1.96, p = 0.003), especially taurochenodeoxycholic acid (TCDCA, OR = 42.29, CI: 3.54 to 504.63, p = 0.003) after multiple adjustments. Western blot analysis of secreted MUC5AC in human primary cholangiocytes treated with primary conjugated BAs or with TCDCA alone allowed us to identify a novel 230 kDa isoform, possibly representing a post-translationally modified MUC5AC specie.


Asunto(s)
Neoplasias de los Conductos Biliares , Colangiocarcinoma , Humanos , Ácidos y Sales Biliares , Mucina 5AC , Estudios de Casos y Controles , Conductos Biliares Intrahepáticos
16.
BMC Med ; 20(1): 96, 2022 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-35197073

RESUMEN

BACKGROUND: The active surveillance of students is proposed as an effective strategy to contain SARS-CoV-2 spread and prevent schools' closure. Saliva for molecular testing is as sensitive as naso-pharyngeal swab (NPS), self-collected and well accepted by participants. This prospective study aimed to verify whether the active surveillance of the Padua University employees by molecular testing of self-collected saliva is an effective and affordable strategy for limiting SARS-CoV-2 spread. METHODS: A surveillance program based on self-collection of saliva every 2 weeks (October 2020-June 2021) was conducted. Among 8183 employees of the Padua University, a total of 6284 subjects voluntarily took part in the program. Eight collection points guaranteed the daily distribution and collection of barcoded salivary collection devices, which were delivered to the laboratory by a transport service for molecular testing. Quarantine of positive cases and contact tracing were promptly activated. RESULTS: Among 6284 subjects, 206 individuals were SARS-CoV-2 positive (99 by salivary testing; 107 by NPS performed for contact tracing or symptoms). The cumulative SARS-CoV-2 incidence in this cohort was 3.1%, significantly lower than that of employees not in surveillance (8.0%), in Padua (7.1%) and in the Veneto region (7.2%). Employees with positive saliva results were asymptomatic or had mild symptoms. The levels of serum antibodies after 3 months from the infection were correlated with age and Ct values, being higher in older subjects with greater viral loads. CONCLUSIONS: Salivary-based surveillance with contact tracing effectively allowed to limit SARS-CoV-2 contagion, also in a population with a high incidence.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anciano , Humanos , Pandemias , Estudios Prospectivos , Saliva
17.
Clin Chem Lab Med ; 60(12): 1875-1880, 2022 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-35850928

RESUMEN

During the last few years, clinical laboratories have faced a sea change, from facilities producing a high volume of low-cost test results, toward a more integrated and patient-centered service. Parallel to this paradigm change, the digitalization of healthcare data has made an enormous quantity of patients' data easily accessible, thus opening new scenarios for the utilization of artificial intelligence (AI) tools. Every day, clinical laboratories produce a huge amount of information, of which patients' results are only a part. The laboratory information system (LIS) may include other "relevant" compounding data, such as internal quality control or external quality assessment (EQA) results, as well as, for example, timing of test requests and of blood collection and exams transmission, these data having peculiar characteristics typical of big data, as volume, velocity, variety, and veracity, potentially being used to generate value in patients' care. Despite the increasing interest expressed in AI and big data in laboratory medicine, these topics are approaching the discipline slowly for several reasons, attributable to lack of knowledge and skills but also to poor or absent standardization, harmonization and problematic regulatory and ethical issues. Finally, it is important to bear in mind that the mathematical postulation of algorithms is not sufficient for obtaining useful clinical tools, especially when biological parameters are not evaluated in the appropriate context. It is therefore necessary to enhance cooperation between laboratory and AI experts, and to coordinate and govern processes, thus favoring the development of valuable clinical tools.


Asunto(s)
Inteligencia Artificial , Macrodatos , Humanos , Algoritmos , Atención a la Salud , Conocimiento
18.
Clin Chem Lab Med ; 60(12): 2017-2026, 2022 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-36067004

RESUMEN

OBJECTIVES: The Italian Society of Clinical Biochemistry and Clinical Molecular Biology (SIBioC) Big Data and Artificial Intelligence (BAI) Working Group promoted a survey to frame the knowledge, skills and technological predisposition in clinical laboratories. METHODS: A questionnaire, focussing on digitization, information technology (IT) infrastructures, data accessibility, and BAI projects underway was sent to 1,351 SIBioC participants. The responses were evaluated using SurveyMonkey software and Google Sheets. RESULTS: The 227 respondents (17%) from all over Italy (47% of 484 labs), mainly biologists, laboratory physicians and managers, mostly from laboratories of public hospitals, revealed lack of hardware, software and corporate Wi-Fi, and dearth of PCs. Only 25% work daily on clouds, while 65%-including Laboratory Directors-cannot acquire health data from sources other than laboratories. Only 50% of those with access can review a clinical patient's health record, while the other access only to laboratory information. The integration of laboratory data with other health data is mostly incomplete, which limits BAI-type analysis. Many are unaware of integration platforms. Over 90% report pulling data from the Laboratory Information System, with varying degrees of autonomy. Very few have already undertaken BAI projects, frequently relying on IT partnerships. The majority consider BAI as crucial in helping professional judgements, indicating a growing interest. CONCLUSIONS: The questionnaire received relevant feedback from SIBioC participants. It highlighted the level of expertise and interest in BAI applications. None of the obstacles stands out more than the others, emphasising the need to all-around work: IT infrastructures, data warehouses, BAI analysis software acquisition, data accessibility and training.


Asunto(s)
Macrodatos , Servicios de Laboratorio Clínico , Humanos , Inteligencia Artificial , Laboratorios Clínicos , Encuestas y Cuestionarios , Laboratorios
19.
Clin Chem Lab Med ; 60(5): 766-770, 2022 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-35041302

RESUMEN

OBJECTIVES: The reliable identification of individuals with SARS-CoV-2 infection is the cornerstone for containing viral spread. Rapid molecular point-of-care testing (POCT) of saliva might reduce analysis time, thus increasing the efficacy of contact tracing. In this study, a new POCT RT-PCR assay for the detection of SARS-CoV-2 RNA in saliva was evaluated and compared with an already validated CE-IVD method. METHODS: An evaluation was made of 160 left-over salivary samples (27 frozen, kept at -80 °C and 133 fresh), collected using Salivette (Sarstedt, Germany). Samples were analyzed by TaqPath COVID-19 CE-IVD RT-PCR kit, QuantStudio5 Real-Time (Applied Biosystems, USA) (TaqPath) and bKIT Virus Finder COVID-19 Saliva (Hyris Global Diagnostics, Italy). Performances of three- and fivefold pooling strategies were also evaluated. Blood assay interference in saliva was also tested with Hyris. RESULTS: On using TaqPath, SARS-CoV-2 positivity was detected in 35 samples. Another 10 positive samples were artificially-generated by blind mixing of positive with negative samples. Hyris positive and negative percentages of agreement were 97.6 (95% CI: 87.2-99.9%) and 100 (95% CI: 97.0-100%), respectively. Seventeen positive pools, evaluated for threefold strategy, were all correctly determined by both systems. For the 5-pool strategy, 94.7% (18/19) of samples resulted positive with the Hyris system, and 100% with TaqPath. The presence of 1% of blood (v/v) in saliva did not interfere with the accuracy of Hyris assay. CONCLUSIONS: The sensitivity and specificity of the bKIT Virus Finder COVID-19 Saliva were optimal with respect to TaqPath. In view of the safe and straightforward pre-analytical procedure involved, and the small size of the Hyris bCube, the Hyris system can be used for POCT.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Pruebas en el Punto de Atención , ARN Viral/análisis , ARN Viral/genética , SARS-CoV-2/genética , Saliva/química , Sensibilidad y Especificidad
20.
Clin Chem Lab Med ; 60(7): 1110-1115, 2022 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-35473824

RESUMEN

OBJECTIVES: The waning of humoral immunity after COVID-19 vaccine booster (third dose) has not yet been fully evaluated. This study updates data on anti-SARS-CoV-2 spike protein receptor binding domain (S-RBD) binding antibodies (bAb) and neutralizing antibodies (NAb) levels in individuals with homologous vaccination 3-4 months after receiving the booster dose. METHODS: Fifty-five healthcare workers (HCW) from Padova University-Hospital were asked to collect serum samples for determining antibodies (Ab) at 12 (t12) and 28 (t28) days, at 6 months (t6m) after their first Comirnaty/BNT162b2 inoculation, and 3-4 months after receiving the 3rd homologous booster dose. HCW were monitored weekly for SARS-CoV-2 infection. Ab titers were measured by two chemiluminescent immunoassays, one targeting the S-RBD immunoglobulin G (IgG), and one surrogate viral neutralization test (sVNT), measuring NAb. RESULTS: Twenty of the HCW had natural COVID-19 infection (COVID+) at different times, before either the first or the second vaccination. Median S-RBD IgG and NAb levels and their interquartile ranges 3-4 months after the 3rd dose were 1,076 (529-3,409) kBAU/L and 15.8 (11.3-38.3) mg/L, respectively, for COVID-, and 1,373 (700-1,373) kBAU/L and 21 (12.8-53.9) mg/L, respectively, for COVID+. At multivariate regression analyses, with age and gender included as covariates, S-RBD IgG bAb and sVNT NAb levels were closely associated with the time interval between serological determination and the 3rd vaccine dose (log10 ßcoeff=-0.013, p=0.012 and log10 ßcoeff=-0.010, p=0.025) for COVID+, whereas no such association was found in COVID- individuals. CONCLUSIONS: The third booster dose increases anti-SARS-CoV-2 Ab levels, elevated levels persisting for up to 3-4 months. Waning of Ab levels appears to be less pronounced for COVID+ individuals.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anticuerpos Neutralizantes , Anticuerpos Antivirales , Vacuna BNT162 , Vacunas contra la COVID-19 , Estudios de Cohortes , Personal de Salud , Humanos , Inmunización Secundaria , Inmunoglobulina G
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA