Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Asunto principal
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Inherit Metab Dis ; 42(1): 128-139, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30740731

RESUMEN

PURPOSE: To assess how the current practice of newborn screening (NBS) for homocystinurias compares with published recommendations. METHODS: Twenty-two of 32 NBS programmes from 18 countries screened for at least one form of homocystinuria. Centres provided pseudonymised NBS data from patients with cystathionine beta-synthase deficiency (CBSD, n = 19), methionine adenosyltransferase I/III deficiency (MATI/IIID, n = 28), combined remethylation disorder (cRMD, n = 56) and isolated remethylation disorder (iRMD), including methylenetetrahydrofolate reductase deficiency (MTHFRD) (n = 8). Markers and decision limits were converted to multiples of the median (MoM) to allow comparison between centres. RESULTS: NBS programmes, algorithms and decision limits varied considerably. Only nine centres used the recommended second-tier marker total homocysteine (tHcy). The median decision limits of all centres were ≥ 2.35 for high and ≤ 0.44 MoM for low methionine, ≥ 1.95 for high and ≤ 0.47 MoM for low methionine/phenylalanine, ≥ 2.54 for high propionylcarnitine and ≥ 2.78 MoM for propionylcarnitine/acetylcarnitine. These decision limits alone had a 100%, 100%, 86% and 84% sensitivity for the detection of CBSD, MATI/IIID, iRMD and cRMD, respectively, but failed to detect six individuals with cRMD. To enhance sensitivity and decrease second-tier testing costs, we further adapted these decision limits using the data of 15 000 healthy newborns. CONCLUSIONS: Due to the favorable outcome of early treated patients, NBS for homocystinurias is recommended. To improve NBS, decision limits should be revised considering the population median. Relevant markers should be combined; use of the postanalytical tools offered by the CLIR project (Collaborative Laboratory Integrated Reports, which considers, for example, birth weight and gestational age) is recommended. tHcy and methylmalonic acid should be implemented as second-tier markers.


Asunto(s)
Homocistinuria/diagnóstico , Acetilcarnitina/metabolismo , Errores Innatos del Metabolismo de los Aminoácidos/diagnóstico , Errores Innatos del Metabolismo de los Aminoácidos/metabolismo , Carnitina/análogos & derivados , Carnitina/metabolismo , Femenino , Glicina N-Metiltransferasa/deficiencia , Glicina N-Metiltransferasa/metabolismo , Homocisteína/metabolismo , Homocistinuria/metabolismo , Humanos , Recién Nacido , Masculino , Metionina/metabolismo , Metilenotetrahidrofolato Reductasa (NADPH2)/deficiencia , Metilenotetrahidrofolato Reductasa (NADPH2)/metabolismo , Ácido Metilmalónico/metabolismo , Espasticidad Muscular/diagnóstico , Espasticidad Muscular/metabolismo , Tamizaje Neonatal/métodos , Fenilalanina/metabolismo , Trastornos Psicóticos/diagnóstico , Trastornos Psicóticos/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA