Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 274
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Lancet ; 403(10436): 1576-1589, 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38554728

RESUMEN

Valvular heart disease is common and its prevalence is rapidly increasing worldwide. Effective medical therapies are insufficient and treatment was historically limited to the surgical techniques of valve repair or replacement, resulting in systematic underprovision of care to older patients and those with substantial comorbidities, frailty, or left ventricular dysfunction. Advances in imaging and surgical techniques over the past 20 years have transformed the management of valvular heart disease. Better understanding of the mechanisms and causes of disease and an increasingly extensive and robust evidence base provide a platform for the delivery of individualised treatment by multidisciplinary heart teams working within networks of diagnostic facilities and specialist heart valve centres. In this Series paper, we aim to provide an overview of the current and future management of valvular heart disease and propose treatment approaches based on an understanding of the underlying pathophysiology and the application of multidisciplinary treatment strategies to individual patients.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Disfunción Ventricular Izquierda , Humanos , Enfermedades de las Válvulas Cardíacas/cirugía
2.
Eur Heart J ; 45(11): 876-894, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38426859

RESUMEN

Transcatheter tricuspid valve interventions (TTVI) are emerging as alternatives to surgery in high-risk patients with isolated or concomitant tricuspid regurgitation. The development of new minimally invasive solutions potentially more adapted to this largely undertreated population of patients, has fuelled the interest for the tricuspid valve. Growing evidence and new concepts have contributed to revise obsolete and misleading perceptions around the right side of the heart. New definitions, classifications, and a better understanding of the disease pathophysiology and phenotypes, as well as their associated patient journeys have profoundly and durably changed the landscape of tricuspid disease. A number of registries and a recent randomized controlled pivotal trial provide preliminary guidance for decision-making. TTVI seem to be very safe and effective in selected patients, although clinical benefits beyond improved quality of life remain to be demonstrated. Even if more efforts are needed, increased disease awareness is gaining momentum in the community and supports the establishment of dedicated expert valve centres. This review is summarizing the achievements in the field and provides perspectives for a less invasive management of a no-more-forgotten disease.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Calidad de Vida , Cateterismo Cardíaco/efectos adversos , Insuficiencia de la Válvula Tricúspide/etiología , Resultado del Tratamiento
3.
Eur Heart J ; 45(3): 161-177, 2024 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-37638967

RESUMEN

BACKGROUND AND AIMS: The European Union Medical Device Regulation 2017/745 challenges key stakeholders to follow transparent and rigorous approaches to the clinical evaluation of medical devices. The purpose of this study is a systematic evaluation of published clinical evidence underlying selected high-risk cardiovascular medical devices before and after market access in the European Union (CE-marking) between 2000 and 2021. METHODS: Pre-specified strategies were applied to identify published studies of prospective design evaluating 71 high-risk cardiovascular devices in seven different classes (bioresorbable coronary scaffolds, left atrial appendage occlusion devices, transcatheter aortic valve implantation systems, transcatheter mitral valve repair/replacement systems, surgical aortic and mitral heart valves, leadless pacemakers, subcutaneous implantable cardioverter-defibrillator). The search time span covered 20 years (2000-21). Details of study design, patient population, intervention(s), and primary outcome(s) were summarized and assessed with respect to timing of the corresponding CE-mark approval. RESULTS: At least one prospective clinical trial was identified for 70% (50/71) of the pre-specified devices. Overall, 473 reports of 308 prospectively designed studies (enrolling 97 886 individuals) were deemed eligible, including 81% (251/308) prospective non-randomized clinical trials (66 186 individuals) and 19% (57/308) randomized clinical trials (31 700 individuals). Pre-registration of the study protocol was available in 49% (150/308) studies, and 16% (48/308) had a peer-reviewed publicly available protocol. Device-related adverse events were evaluated in 82% (253/308) of studies. An outcome adjudication process was reported in 39% (120/308) of the studies. Sample size was larger for randomized in comparison to non-randomized trials (median of 304 vs. 100 individuals, P < .001). No randomized clinical trial published before CE-mark approval for any of the devices was identified. Non-randomized clinical trials were predominantly published after the corresponding CE-mark approval of the device under evaluation (89%, 224/251). Sample sizes were smaller for studies published before (median of 31 individuals) than after (median of 135 individuals) CE-mark approval (P < .001). Clinical trials with larger sample sizes (>50 individuals) and those with longer recruitment periods were more likely to be published after CE-mark approval, and were more frequent during the period 2016-21. CONCLUSIONS: The quantity and quality of publicly available data from prospective clinical investigations across selected categories of cardiovascular devices, before and after CE approval during the period 2000-21, were deemed insufficient. The majority of studies was non-randomized, with increased risk of bias, and performed in small populations without provision of power calculations, and none of the reviewed devices had randomized trial results published prior to CE-mark certification.


Asunto(s)
Sistema Cardiovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Corazón , Prótesis e Implantes , Unión Europea
4.
Eur Heart J ; 45(11): 895-911, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38441886

RESUMEN

Atrial secondary tricuspid regurgitation (A-STR) is a distinct phenotype of secondary tricuspid regurgitation with predominant dilation of the right atrium and normal right and left ventricular function. Atrial secondary tricuspid regurgitation occurs most commonly in elderly women with atrial fibrillation and in heart failure with preserved ejection fraction in sinus rhythm. In A-STR, the main mechanism of leaflet malcoaptation is related to the presence of a significant dilation of the tricuspid annulus secondary to right atrial enlargement. In addition, there is an insufficient adaptive growth of tricuspid valve leaflets that become unable to cover the enlarged annular area. As opposed to the ventricular phenotype, in A-STR, the tricuspid valve leaflet tethering is typically trivial. The A-STR phenotype accounts for 10%-15% of clinically relevant tricuspid regurgitation and has better outcomes compared with the more prevalent ventricular phenotype. Recent data suggest that patients with A-STR may benefit from more aggressive rhythm control and timely valve interventions. However, little is mentioned in current guidelines on how to identify, evaluate, and manage these patients due to the lack of consistent evidence and variable definitions of this entity in recent investigations. This interdisciplinary expert opinion document focusing on A-STR is intended to help physicians understand this complex and rapidly evolving topic by reviewing its distinct pathophysiology, diagnosis, and multi-modality imaging characteristics. It first defines A-STR by proposing specific quantitative criteria for defining the atrial phenotype and for discriminating it from the ventricular phenotype, in order to facilitate standardization and consistency in research.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/complicaciones , Atrios Cardíacos/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/terapia
5.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38096587

RESUMEN

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Cardiopatía Reumática , Insuficiencia de la Válvula Tricúspide , Humanos , Marcapaso Artificial/efectos adversos , Desfibriladores Implantables/efectos adversos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Cardiopatía Reumática/complicaciones , Estudios Retrospectivos
6.
Eur Heart J ; 45(8): 586-597, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-37624856

RESUMEN

BACKGROUND AND AIMS: Benefit of tricuspid regurgitation (TR) correction and timing of intervention are unclear. This study aimed to compare survival rates after surgical or transcatheter intervention to conservative management according to a TR clinical stage as assessed using the TRI-SCORE. METHODS: A total of 2,413 patients with severe isolated functional TR were enrolled in TRIGISTRY (1217 conservatively managed, 551 isolated tricuspid valve surgery, and 645 transcatheter valve repair). The primary endpoint was survival at 2 years. RESULTS: The TRI-SCORE was low (≤3) in 32%, intermediate (4-5) in 33%, and high (≥6) in 35%. A successful correction was achieved in 97% and 65% of patients in the surgical and transcatheter groups, respectively. Survival rates decreased with the TRI-SCORE in the three treatment groups (all P < .0001). In the low TRI-SCORE category, survival rates were higher in the surgical and transcatheter groups than in the conservative management group (93%, 87%, and 79%, respectively, P = .0002). In the intermediate category, no significant difference between groups was observed overall (80%, 71%, and 71%, respectively, P = .13) but benefit of the intervention became significant when the analysis was restricted to patients with successful correction (80%, 81%, and 71%, respectively, P = .009). In the high TRI-SCORE category, survival was not different to conservative management in the surgical and successful repair group (61% and 68% vs 58%, P = .26 and P = .18 respectively). CONCLUSIONS: Survival progressively decreased with the TRI-SCORE irrespective of treatment modality. Compared to conservative management, an early and successful surgical or transcatheter intervention improved 2-year survival in patients at low and, to a lower extent, intermediate TRI-SCORE, while no benefit was observed in the high TRI-SCORE category.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Resultado del Tratamiento , Cateterismo Cardíaco
7.
Eur Heart J ; 44(10): 822-832, 2023 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-36445158

RESUMEN

AIMS: The impact of sexuality in patients with significant tricuspid regurgitation (TR) undergoing transcatheter tricuspid valve intervention (TTVI) is unknown. The aim of this study was to investigate sex-specific outcomes in patients with significant TR treated with TTVI vs. medical therapy alone. METHODS AND RESULTS: The Transcatheter Tricuspid Valve Therapies (TriValve) registry collected data on patients with significant TR from 24 centres who underwent TTVI from 2016 to 2021. A control cohort was formed by medically managed patients with ≥severe isolated TR diagnosed in 2015-18. The primary endpoint was freedom from all-cause mortality. Secondary endpoints were heart failure (HF) hospitalization, New York Heart Association (NYHA) functional status, and TR severity. One-year outcomes were assessed for the TriValve cohort and compared with the control cohort with the inverse probability of treatment weighting (IPTW). A total of 556 and 2072 patients were included from the TriValve and control groups, respectively. After TTVI, there was no difference between women and men in 1-year freedom from all-cause mortality 80.9% vs. 77.9%, P = 0.56, nor in HF hospitalization (P = 0.36), NYHA Functional Classes III and IV (P = 0.17), and TR severity >2+ at last follow-up (P = 0.42). Multivariable Cox-regression weighted by IPTW showed improved 1-year survival after TTVI compared with medical therapy alone in both women (adjusted hazard ratio 0.45, 95% confidence interval 0.23-0.83, P = 0.01) and men (adjusted hazard ratio 0.42, 95% confidence interval 0.18-0.89, P = 0.03). CONCLUSION: After TTVI in high-risk patients, there were no sex-related differences in terms of survival, HF hospitalization, functional status, and TR reduction up to 1 year. The IPTW analysis shows a survival benefit of TTVI over medical therapy alone in both women and men.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Masculino , Humanos , Femenino , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Sistema de Registros , Insuficiencia Cardíaca/complicaciones
8.
Am Heart J ; 256: 104-116, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36400186

RESUMEN

BACKGROUND: Coronary computed tomography angiography (CCTA) is widely adopted to detect obstructive coronary artery disease (CAD) in patients with chronic coronary syndromes (CCS). However, it is unknown to which extent study-specific characteristics yield different conclusions. METHODS: We summarized non-randomized and randomized studies comparing CCTA and noninvasive functional testing for CCS with information on the outcome of myocardial infarction (MI). We evaluated the differential effect according to study characteristics using random-effect meta-analysis with Hartung-Knapp-Sidik-Jonkman adjustments. RESULTS: Fifteen studies (8 non-randomized, 7 randomized) were included. CCTA was associated with decrease in relative (odds ratio (OR) 0.54, 95%CI 0.47 to 0.62, P < .001) and absolute MI risk (risk difference (RD) -0.4%, 95%CI -0.6 to -0.1, P = .005). The results remained consistent among the non-randomized (RD -0.4%, 95%CI -0.7 to -0.1, P=.029), but not among the randomized trials where there was no difference in the observed risk (RD 0.2%, 95%CI -0.6 to 0.1, P = .158). CCTA was not associated with MI reduction in studies with clinical outcome definition (OR 0.77, 95%CI 0.41 to 1.44, P = .212), research driven follow-up (OR 0.54, 95%CI 0.24 to 1.21, P = .090), central event assessment (OR 0.63, 95%CI 0.21 to 1.86, P = .207), outcome adjudication (OR 0.74, 95%CI 0.24 to 2.23, P = .178), or at low-risk of bias (OR 0.74, 95%CI 0.24 to 2.23, P = .178). CONCLUSIONS: Among studies of any design, CCTA was associated with lower risk of MI in CCS compared to noninvasive functional testing. This benefit was diminished among studies with clinical outcome definition, central outcome assessment/adjudication or at low-risk of bias.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Humanos , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/complicaciones , Infarto del Miocardio/complicaciones , Tomografía Computarizada por Rayos X/métodos , Ensayos Clínicos Controlados no Aleatorios como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto
9.
Artículo en Inglés | MEDLINE | ID: mdl-37327913

RESUMEN

BACKGROUND: The aim of this study was to report outcomes of all patients undergoing transcatheter mitral valve implantation with the Tendyne Mitral Valve System (Tendyne) in Switzerland. METHODS: We retrospectively analyzed preoperative echocardiographic and computed tomography (CT) data, procedural findings, and 30-day and 1-year follow-up echocardiographic and clinical data of patients who underwent transcatheter mitral valve implantation with Tendyne in Switzerland. RESULTS: A total of 24 patients (age, 74.8 ± 7.8 years; 67% male) underwent transapical transcatheter mitral valve implantation with Tendyne between June 2020 and October 2022. Technical success rate was 96%. In five patients, concomitant interventions in the form of transcatheter aortic valve implantation (one patient), minimally invasive direct coronary artery bypass (one patient), and transcatheter edge-to-edge repair (three patients) were performed prior to or after the index procedure. There was one device embolization, and two patients required valve retrieval. In-hospital outcomes included one stroke and three major bleeding events. None of the patients died within 30 days. Two patients were rehospitalized for decompensated heart failure. At 1-year follow-up, there were three noncardiovascular-related deaths. CONCLUSION: Transcatheter mitral valve implantation with Tendyne is feasible to treat polymorbid patients suffering from complex mitral valve disease as well as patients with previous mitral interventions. Perioperative risk was acceptable and procedural success high.

10.
Curr Cardiol Rep ; 25(10): 1361-1371, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37698820

RESUMEN

PURPOSE OF REVIEW: Mitral and tricuspid regurgitation represents a clinical challenge. They are associated with a poor prognosis, and many patients are not eligible for conventional surgery. Transcatheter therapies have been the focus of numerous studies and devices over the past decade. Here, we provide a summary of current options for transcatheter treatment of these 2 entities. RECENT FINDINGS: Recent studies have demonstrated the benefits of edge-to-edge repair for increasing numbers of patients. Encouraging early results with transcatheter valve replacement are also becoming available. To date, transcatheter edge-to-edge repair is currently the first-line transcatheter treatment for both mitral and tricuspid regurgitation for many patients who are not candidates for surgery. A number of transcatheter replacement devices are under development and clinical investigation but, for the most part, their current use is limited to compassionate cases or clinical trials.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/cirugía
11.
Eur Heart J ; 43(7): 641-650, 2022 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-34463727

RESUMEN

AIMS: Severe mitral regurgitation (MR) following acute myocardial infarction (MI) is associated with high mortality rates and has inconclusive recommendations in clinical guidelines. We aimed to report the international experience of patients with secondary MR following acute MI and compare the outcomes of those treated conservatively, surgically, and percutaneously. METHODS AND RESULTS: Retrospective international registry of consecutive patients with at least moderate-to-severe MR following MI treated in 21 centres in North America, Europe, and the Middle East. The registry included patients treated conservatively and those having surgical mitral valve repair or replacement (SMVR) or percutaneous mitral valve repair (PMVR) using edge-to-edge repair. The primary endpoint was in-hospital mortality. A total of 471 patients were included (43% female, age 73 ± 11 years): 205 underwent interventions, of whom 106 were SMVR and 99 PMVR. Patients who underwent mitral valve intervention were in a worse clinical state (Killip class ≥3 in 60% vs. 43%, P < 0.01), but yet had lower in-hospital and 1-year mortality compared with those treated conservatively [11% vs. 27%, P < 0.01 and 16% vs. 35%, P < 0.01; adjusted hazard ratio (HR) 0.28, 95% confidence interval (CI) 0.18-0.46, P < 0.01]. Surgical mitral valve repair or replacement was performed earlier than PMVR [median of 12 days from MI date (interquartile range 5-19) vs. 19 days (10-40), P < 0.01]. The immediate procedural success did not differ between SMVR and PMVR (92% vs. 93%, P = 0.53). However, in-hospital and 1-year mortality rates were significantly higher in SMVR than in PMVR (16% vs. 6%, P = 0.03 and 31% vs. 17%, P = 0.04; adjusted HR 3.75, 95% CI 1.55-9.07, P < 0.01). CONCLUSIONS: Early intervention may mitigate the poor prognosis associated with conservative therapy in patients with post-MI MR. Percutaneous mitral valve repair can serve as an alternative for surgery in reducing MR for high-risk patients.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Infarto del Miocardio , Anciano , Anciano de 80 o más Años , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Infarto del Miocardio/complicaciones , Infarto del Miocardio/terapia , Estudios Retrospectivos , Resultado del Tratamiento
12.
Rev Med Suisse ; 19(817): 477-485, 2023 Mar 08.
Artículo en Francés | MEDLINE | ID: mdl-36883709

RESUMEN

The negative impact of tricuspid regurgitation on prognosis in now well established. It also appears clear that surgical and possibly percutaneous treatment should be performed before reaching a point of no return with advanced heart failure and deterioration of right ventricle function. Percutaneous treatment has been divided into coaptation restoration devices, annuloplasty devices, and ortho- or heterotopic valve replacement. The present article offers a brief review of diagnostic modalities beyond echocardiography, surgical treatment as well as of the multiple recent development in the percutaneous treatment of this frequent condition.


L'impact pronostique défavorable de l'insuffisance tricuspide (IT) est maintenant bien établi, ainsi que la nécessité d'intervenir chirurgicalement ou de manière percutanée lorsque le traitement médicamenteux est insuffisant. Des données récentes suggèrent par ailleurs qu'il est probablement judicieux d'intervenir avant qu'un stade trop avancé d'insuffisance cardiaque et d'atteinte du ventricule droit ne soit atteint. Le traitement percutané est divisé en dispositifs de restauration de la coaptation valvulaire, d'annuloplastie et de remplacement de valve ortho ou hétérotopique. Cet article propose une brève revue des modalités diagnostiques au-delà de l'échocardiographie, du traitement chirurgical ainsi que des multiples développements récents dans le traitement percutané de cette pathologie fréquente.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Humanos , Ecocardiografía , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Trastornos de la Memoria , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/cirugía
13.
Am Heart J ; 244: 94-106, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34788603

RESUMEN

BACKGROUND: Ascending aortic root anatomy is routinely evaluated on pre-procedural multi-detector computed tomography (MDCT). However, its clinical significance has not been adequately studied. We aimed to investigate the impact of the sinus of Valsalva (SOV) dimension on clinical outcomes in patients undergoing transcatheter aortic valve implantation (TAVI). METHODS: In a prospective TAVI registry, we retrospectively assessed SOV dimensions by pre-procedural MDCT. Patients were stratified according to tertiles of SOV diameter indexed to body surface area (SOVi). The primary endpoint was all-cause mortality at 1 year. RESULTS: Among 2066 consecutive patients undergoing TAVI between August 2007 and June 2018, 1554 patients were eligible for the present analysis. Patients in the large SOVi group were older (83 ± 6 vs 82 ± 6 vs 81 ± 6; P < .001) and had a higher Society of Thoracic Surgeons Predicted Risk of Mortality (6.3 ± 3.8 vs 5.1 ± 3.1 vs 4.9 ± 3.5; P < .001) than those in the other groups. Patients in the large SOVi group had a higher incidence of moderate or severe paravalvular regurgitation (11.9% vs 4.5% vs 3.5%; P < .001). At 1 year, a large SOVi was independently associated with an increased risk of mortality (HR: 1.62; 95% CI: 1.19-2.21; P = .002) and major or life-threatening bleeding (HR: 1.30; 95% CI: 1.02-1.65; P = .035). CONCLUSIONS: Dilatation of the aortic root at the SOV was associated with adverse outcomes after TAVI. The assessment of the aortic root should be integrated into the risk stratification system in patients undergoing TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Seno Aórtico , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Estudios Prospectivos , Estudios Retrospectivos , Seno Aórtico/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
14.
Rev Cardiovasc Med ; 23(7): 220, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39076922

RESUMEN

Tricuspid regurgitation (TR) negatively affects patient outcomes. Surgical tricuspid valve repair/replacement carries a high operative risk and is not a viable option for many high-risk patients. Percutaneous approaches provide an attractive alternative solution for such patients since they represent a valid alternative to open heart surgery without the significant risks carried by surgery. A number of percutaneous devices are currently under clinical development. This review will discuss about the latest development in the field of percutaneous tricuspid valve repair with possible future developments.

15.
Catheter Cardiovasc Interv ; 99(6): 1908-1917, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35170846

RESUMEN

BACKGROUND: Increased left ventricular afterload resulting from severe aortic stenosis (AS) leads to progressive cardiac remodeling. Left atrial enlargement (LAE) is an early manifestation in a series of maladaptive changes and may affect clinical outcomes after valvular replacement therapy. The aim of this study is to determine the impact of LAE on clinical outcomes in symptomatic patients with severe AS undergoing transcatheter aortic valve implantation (TAVI). METHODS: In a prospective single-center TAVI registry, we analyzed LA dimensions measured by echocardiography before intervention. Patients with atrial fibrillation or concomitant mitral valve disease were excluded. LAE was defined as indexed LA volume >34 ml/m2 . The primary endpoint was cardiovascular death (CVD) at 1 year. RESULTS: Among 1663 patients undergoing TAVI between August 2007 and December 2016, 768 (46.2%) were eligible for the present analysis and 486 patients had LAE. The prevalence of LAE was higher in males (68.3%) as compared to females (58.8%). Patients with LAE were older (82.3 ± 6.7 years vs. 80.0 ± 6.4 years) and had a higher STS-PROM score (6.1 ± 4.7% vs. 4.7 ± 2.9%). After adjustment, patients with LAE had an increased risk of CVD at 1-year compared to patients with normal LA dimensions (49 [10.4%] vs. 8 [2.9%]; HRadj , 3.52; 95% CI, 1.66-7.44)]. In multivariable analysis, LAE was independently associated with an increased risk of CVD at 1-year (HRadj , 3.52; 95% CI, 1.66-7.44). CONCLUSIONS: LAE secondary to AS was documented in a significant proportion of patients undergoing TAVI and was associated with a more than threefold increased risk of CVD at 1-year.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía/métodos , Femenino , Humanos , Masculino , Estudios Prospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
16.
BMC Cardiovasc Disord ; 22(1): 178, 2022 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-35436856

RESUMEN

BACKGROUND: Computed tomography angiography (CTA) is a cornerstone in the pre- transcatheter aortic valve replacement (TAVI) assessment. We evaluated the diagnostic performance of CTA and coronary artery calcium score (CACS) for CAD evaluation compared to invasive coronary angiography in a cohort of TAVI patients. METHODS: In consecutive TAVI patients without prior coronary revascularization and device implants, CAD was assessment by quantitative analysis in CTA. (a) Patients with non-evaluable segments were classified as obstructive CAD. (b) In patients with non-evaluable segments a CACS cut-off of 100 was applied for obstructive CAD. The reference standard was quantitative invasive coronary angiography (QCA, i.e. ≥ 50% stenosis). RESULTS: 100 consecutive patients were retrospectively included, age was 82.3 ± 6.5 years and 30% of patients had CAD. In 16% of the patients, adequate visualization of the entire coronary tree (all 16 segments) was possible with CTA, while 84% had at least one segment which was not evaluable for CAD analysis due to impaired image quality. On a per-patient analysis, where patients with low image quality were classified as CAD, CTA showed a sensitivity of 100% (95% CI 88.4-100.0), specificity of 11.4% (95% CI 5.1-21.3), PPV of 32.6% (95% CI 30.8-34.5), NPV of 100% and diagnostic accuracy of 38% (95% CI 28.5-48.3) for obstructive CAD. When applying a combined approach of CTA (in patients with good image quality) and CACS (in patients with low image quality), the sensitivity and NPV remained at 100% and obstructive CAD could be ruled out in 20% of the TAVI patients, versus 8% using CTA alone. CONCLUSION: In routinely acquired pre-TAVI CTA, the image quality was insufficient in a high proportion of patients for the assessment of the entire coronary artery tree. However, when adding CACS in patients with low image quality to quantitative CTA assessment in patients with good image quality, obstructive CAD could be ruled-out in 1/5 of the patients and may therefore constitute a strategy to streamline pre-procedural workup, and reduce risk, radiation and costs in selected TAVI patients without prior coronary revascularization or device implants.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
17.
Eur Heart J ; 42(13): 1254-1269, 2021 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-33734354

RESUMEN

Secondary (or functional) mitral regurgitation (SMR) occurs frequently in chronic heart failure (HF) with reduced left ventricular (LV) ejection fraction, resulting from LV remodelling that prevents coaptation of the valve leaflets. Secondary mitral regurgitation contributes to progression of the symptoms and signs of HF and confers worse prognosis. The management of HF patients with SMR is complex and requires timely referral to a multidisciplinary Heart Team. Optimization of pharmacological and device therapy according to guideline recommendations is crucial. Further management requires careful clinical and imaging assessment, addressing the anatomical and functional features of the mitral valve and left ventricle, overall HF status, and relevant comorbidities. Evidence concerning surgical correction of SMR is sparse and it is doubtful whether this approach improves prognosis. Transcatheter repair has emerged as a promising alternative, but the conflicting results of current randomized trials require careful interpretation. This collaborative position statement, developed by four key associations of the European Society of Cardiology-the Heart Failure Association (HFA), European Association of Percutaneous Cardiovascular Interventions (EAPCI), European Association of Cardiovascular Imaging (EACVI), and European Heart Rhythm Association (EHRA)-presents an updated practical approach to the evaluation and management of patients with HF and SMR based upon a Heart Team approach.

18.
Heart Lung Circ ; 31(9): 1203-1218, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35680498

RESUMEN

BACKGROUND: To tailor cardiovascular interventions, the use of three-dimensional (3D), patient-specific phantoms (3DPSP) encompasses patient education, training, simulation, procedure planning, and outcome-prediction. AIM: This systematic review and meta-analysis aims to investigate the current and future perspective of 3D printing for cardiovascular interventions. METHODS: We systematically screened articles on Medline and EMBASE reporting the prospective use of 3DPSP in cardiovascular interventions by using combined search terms. Studies that compared intervention time depending on 3DPSP utilisation were included into a meta-analysis. RESULTS: We identified 107 studies that prospectively investigated a total of 814 3DPSP in cardiovascular interventions. Most common settings were congenital heart disease (CHD) (38 articles, 6 comparative studies), left atrial appendage (LAA) occlusion (11 articles, 5 comparative, 1 randomised controlled trial [RCT]), and aortic disease (10 articles). All authors described 3DPSP as helpful in assessing complex anatomic conditions, whereas poor tissue mimicry and the non-consideration of physiological properties were cited as limitations. Compared to controls, meta-analysis of six studies showed a significant reduction of intervention time in LAA occlusion (n=3 studies), and surgery due to CHD (n=3) if 3DPSPs were used (Cohen's d=0.54; 95% confidence interval 0.13 to 0.95; p=0.001), however heterogeneity across studies should be taken into account. CONCLUSIONS: 3DPSP are helpful to plan, train, and guide interventions in patients with complex cardiovascular anatomy. Benefits for patients include reduced intervention time with the potential for lower radiation exposure and shorter mechanical ventilation times. More evidence and RCTs including clinical endpoints are needed to warrant adoption of 3DPSP into routine clinical practice.


Asunto(s)
Cardiopatías Congénitas , Impresión Tridimensional , Diagnóstico por Imagen , Humanos , Pronóstico
19.
Catheter Cardiovasc Interv ; 98(5): E768-E779, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-33857355

RESUMEN

OBJECTIVES: To investigate the impact of transcatheter heart valve (THV) sizing on procedural results and clinical outcomes following transcatheter aortic valve implantation (TAVI). BACKGROUND: The impact of individual THV sizing for patients with borderline aortic annulus anatomy remains unclear. METHODS: In the prospective BernTAVI registry, THV sizing conditions were retrospectively evaluated, and patients were categorized into three groups based on the recommendations and the sizing chart of the manufacturers: optimal sizing, borderline sizing (THV size located within 5% to each border of the optimal sizing recommendation), and suboptimal sizing (THV size outside the recommended range). The latter two groups were further subcategorized into THV-oversizing and THV-undersizing. The primary endpoint was a composite of all-cause death and unplanned repeat intervention at 1 year. RESULTS: Out of a total of 1,638 patients who underwent TAVI, 9.5 and 15.6% of patients were categorized into the borderline and suboptimal sizing group, respectively. Device success was achieved in 87.4, 88.9, and 83.6% of patients with optimal, borderline, and suboptimal sizing, respectively. The primary endpoint occurred in 12.3% of patients with optimal sizing, 14.9% of patients with borderline sizing (HRadj 1.35, 95%CI 0.87-2.09), and in 17.4% of patients with suboptimal sizing (HRadj 1.42, 95%CI 1.01-1.99). Within the suboptimal sizing cohort, unfavorable outcomes were mainly associated with THV undersizing (device success: 76.4%, primary endpoint: 23.9%, HRadj 1.98, 95%CI 1.36-2.87). CONCLUSION: Suboptimal TAVI prosthesis sizing is associated with an increased risk of all-cause death and unplanned repeat intervention within 1 year largely attributable to undersized THV prostheses.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Tomografía Computarizada Multidetector , Estudios Prospectivos , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
20.
Catheter Cardiovasc Interv ; 98(7): 1404-1412, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34406713

RESUMEN

OBJECTIVES: To investigate whether the integrative echocardiographic criteria used in the cardiovascular outcomes assessment of the mitraclip percutaneous therapy (COAPT) for heart failure patients with functional mitral regurgitation study predict outcomes after edge-to-edge trancatheter mitral valve repair (TMVr) for the treatment of secondary mitral regurgitation (SMR). BACKGROUND: Two randomized controlled trials comparing TMVr to medical treatment reported conflicting findings. Differences in patient selection criteria may have contributed to these diverging results. METHODS: Patients undergoing TMVr were stratified following the integrative COAPT echocardiographic criteria in noneligible and eligible patients who were further classified into three tiers according to effective regurgitant orifice (EROA) (Tier 1: EROA ≥ 0.3cm2 ; Tier 2: EROA 0.2cm2 and 0.29cm2 ; Tier 3: EROA<0.2cm2 ) combined with several other severity criteria. We assessed between group differences in all-cause mortality, successful SMR reduction, and symptom relief from baseline to 2-year follow-up. RESULTS: Between March 2011 and March 2018, 138 patients (mean age 75 years) satisfying the inclusion criteria underwent TMVr for treatment of symptomatic SMR. The mean EROA area was 0.35 ± 0.17 mm2 . Ten patients (7%) died within 30 days, 29 (21%) within 12 months, and 41 (30%) within 2 years. After stratification according to the COAPT echocardiographic criteria that were fulfilled in 72% of the studied population, Tier 2 patients (45%), as well as noneligible patients (38%) had a higher mortality rate compared to those in Tier 1 (19%). CONCLUSIONS: SMR patients stratified into tiers according to the COAPT integrative echocardiographic criteria have diverging prognostic and symptomatic benefit after edge-to-edge TMVr.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Cateterismo Cardíaco/efectos adversos , Ecocardiografía , Insuficiencia Cardíaca/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA