Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 92(3): 1138-1148, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38730565

RESUMEN

PURPOSE: To develop a highly accelerated multi-echo spin-echo method, TEMPURA, for reducing the acquisition time and/or increasing spatial resolution for kidney T2 mapping. METHODS: TEMPURA merges several adjacent echoes into one k-space by either combining independent echoes or sharing one echo between k-spaces. The combined k-space is reconstructed based on compressed sensing theory. Reduced flip angles are used for the refocusing pulses, and the extended phase graph algorithm is used to correct the effects of indirect echoes. Two sequences were developed: a fast breath-hold sequence; and a high-resolution sequence. The performance was evaluated prospectively on a phantom, 16 healthy subjects, and two patients with different types of renal tumors. RESULTS: The fast TEMPURA method reduced the acquisition time from 3-5 min to one breath-hold (18 s). Phantom measurements showed that fast TEMPURA had a mean absolute percentage error (MAPE) of 8.2%, which was comparable to a standardized respiratory-triggered sequence (7.4%), but much lower than a sequence accelerated by purely k-t undersampling (21.8%). High-resolution TEMPURA reduced the in-plane voxel size from 3 × 3 to 1 × 1 mm2, resulting in improved visualization of the detailed anatomical structure. In vivo T2 measurements demonstrated good agreement (fast: MAPE = 1.3%-2.5%; high-resolution: MAPE = 2.8%-3.3%) and high correlation coefficients (fast: R = 0.85-0.98; high-resolution: 0.82-0.96) with the standardized method, outperforming k-t undersampling alone (MAPE = 3.3-4.5%, R = 0.57-0.59). CONCLUSION: TEMPURA provides fast and high-resolution renal T2 measurements. It has the potential to improve clinical throughput and delineate intratumoral heterogeneity and tissue habitats at unprecedented spatial resolution.


Asunto(s)
Algoritmos , Neoplasias Renales , Riñón , Fantasmas de Imagen , Humanos , Neoplasias Renales/diagnóstico por imagen , Riñón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Femenino , Adulto , Masculino , Interpretación de Imagen Asistida por Computador/métodos , Reproducibilidad de los Resultados , Persona de Mediana Edad , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Contencion de la Respiración
2.
J Magn Reson Imaging ; 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38380700

RESUMEN

BACKGROUND: T2 mapping is valuable to evaluate pathophysiology in kidney disease. However, variations in T2 relaxation time measurements across MR scanners and vendors may occur requiring additional correction. PURPOSE: To harmonize renal T2 measurements between MR vendor platforms, and use an extended-phase-graph-based fitting method ("StimFit") to correct stimulated echoes and reduce between-vendor variations. STUDY TYPE: Prospective. SUBJECTS: 8 healthy "travelling" volunteers (37.5% female, 32 ± 6 years) imaged on four MRI systems across three vendors at four sites, 10 healthy volunteers (50% female, 32 ± 8 years) scanned multiple times on a given MR scanner for repeatability evaluation. ISMRM/NIST system phantom scanned for evaluation of T2 accuracy. FIELD STRENGTH/SEQUENCE: 3T, multiecho spin-echo sequence. ASSESSMENT: T2 images fit using conventional monoexponential fitting and "StimFit." Mean absolute percentage error (MAPE) of phantom measurements with reference T2 values. Average cortex and medulla T2 values compared between MR vendors, with masks obtained from T2 -weighted images and T1 maps. Full-width-at-half-maximum (FWHM) T2 distributions to evaluate local homogeneity of measurements. STATISTICAL TESTS: Coefficient of variation (CV), linear mixed-effects model, analysis of variance, student's t-tests, Bland-Altman plots, P-value <0.05 considered statistically significant. RESULTS: In the ISMRM/NIST phantom, "StimFit" reduced the MAPE from 4.9%, 9.1%, 24.4%, and 18.1% for the four sites (three vendors) to 3.3%, 3.0%, 6.6%, and 4.1%, respectively. In vivo, there was a significant difference in kidney T2 measurements between vendors using a monoexponential fit, but not with "StimFit" (P = 0.86 and 0.92, cortex and medulla, respectively). The intervendor CVs of T2 measures were reduced from 8.0% to 2.6% (cortex) and 7.1% to 2.8% (medulla) with StimFit, resulting in no significant differences for the CVs of intravendor repeat acquisitions (P = 0.13 and 0.05). "StimFit" significantly reduced the FWHM of T2 distributions in the cortex and whole kidney. DATA CONCLUSION: Stimulated-echo correction reduces renal T2 variation across MR vendor platforms. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.

3.
Radiology ; 309(2): e231173, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37987665

RESUMEN

Background Breast screening enables early detection of cancers; however, most women have normal mammograms, resulting in repetitive and resource-intensive reading tasks. Purpose To investigate if deep learning (DL) algorithms can be used to triage mammograms by identifying normal results to reduce workload or flag cancers that may be overlooked. Materials and Methods In this retrospective study, three commercial DL algorithms were investigated using consecutive mammograms from two UK Breast Screening Program sites from January 2015 to December 2017 and January 2017 to December 2018 on devices from two mammography vendors. Normal mammograms with a 3-year follow-up and histopathologically proven cancer detected at screening, the subsequent round, or in the 3-year interval were included. Two algorithm thresholds were set: in scenario A, 99.0% sensitivity for rule-out triage to a lone reader, and in scenario B, approximately 1.0% additional recall providing a rule-in triage for further assessment. Both thresholds were then applied to the screening workflow in scenario C. The sensitivity and specificity were used to assess the overall predictive performance of each DL algorithm. Results The data set comprised 78 849 patients (median age, 59 years [IQR, 53-63 years]) and 887 screening-detected, 439 interval, and 688 subsequent screening round-detected cancers. In scenario A (rule-out triage), models DL-1, DL-2, and DL-3 triaged 35.0% (27 565 of 78 849), 53.2% (41 937 of 78 849), and 55.6% (43 869 of 78 849) of mammograms, respectively, with 0.0% (0 of 887) to 0.1% (one of 887) of screening-detected cancers undetected. In scenario B, DL algorithms triaged in 4.6% (20 of 439) to 8.2% (36 of 439) of interval and 5.2% (36 of 688) to 6.1% (42 of 688) of subsequent-round cancers when applied after the routine double-reading workflow. Combining both approaches in scenario C resulted in an overall noninferior specificity (difference, -0.9%; P < .001) and superior sensitivity (difference, 2.7%; P < .001) for the adaptive workflow compared with routine double reading for all three algorithms. Conclusion Rule-out and rule-in DL-adapted triage workflows can improve the efficiency and efficacy of mammography breast cancer screening. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Nishikawa and Lu in this issue.


Asunto(s)
Neoplasias de la Mama , Aprendizaje Profundo , Humanos , Femenino , Persona de Mediana Edad , Detección Precoz del Cáncer , Neoplasias de la Mama/diagnóstico por imagen , Estudios Retrospectivos , Triaje , Mamografía , Reino Unido
4.
Br J Cancer ; 127(6): 1051-1060, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35739300

RESUMEN

BACKGROUND: Surgery for renal cell carcinoma (RCC) with venous tumour thrombus (VTT) extension into the renal vein (RV) and/or inferior vena cava (IVC) has high peri-surgical morbidity/mortality. NAXIVA assessed the response of VTT to axitinib, a potent tyrosine kinase inhibitor. METHODS: NAXIVA was a single-arm, multi-centre, Phase 2 study. In total, 20 patients with resectable clear cell RCC and VTT received upto 8 weeks of pre-surgical axitinib. The primary endpoint was percentage of evaluable patients with VTT improvement by Mayo level on MRI. Secondary endpoints were percentage change in surgical approach and VTT length, response rate (RECISTv1.1) and surgical morbidity. RESULTS: In all, 35% (7/20) patients with VTT had a reduction in Mayo level with axitinib: 37.5% (6/16) with IVC VTT and 25% (1/4) with RV-only VTT. No patients had an increase in Mayo level. In total, 75% (15/20) of patients had a reduction in VTT length. Overall, 41.2% (7/17) of patients who underwent surgery had less invasive surgery than originally planned. Non-responders exhibited lower baseline microvessel density (CD31), higher Ki67 and exhausted or regulatory T-cell phenotype. CONCLUSIONS: NAXIVA provides the first Level II evidence that axitinib downstages VTT in a significant proportion of patients leading to reduction in the extent of surgery. CLINICAL TRIAL REGISTRATION: NCT03494816.


Asunto(s)
Axitinib , Carcinoma de Células Renales , Neoplasias Renales , Trombosis , Axitinib/uso terapéutico , Carcinoma de Células Renales/tratamiento farmacológico , Carcinoma de Células Renales/cirugía , Humanos , Neoplasias Renales/tratamiento farmacológico , Neoplasias Renales/cirugía , Terapia Neoadyuvante , Nefrectomía , Estudios Retrospectivos , Trombosis/prevención & control
5.
BJU Int ; 130(2): 244-253, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34549873

RESUMEN

OBJECTIVE: To explore translational biological and imaging biomarkers for sunitinib treatment before and after debulking nephrectomy in the NeoSun (European Union Drug Regulating Authorities Clinical Trials Database [EudraCT] number: 2005-004502-82) single-centre, single-arm, single-agent, Phase II trial. PATIENTS AND METHODS: Treatment-naïve patients with metastatic renal cell carcinoma (mRCC) received 50 mg once daily sunitinib for 12 days pre-surgically, then post-surgery on 4 week-on, 2 week-off, repeating 6-week cycles until disease progression in a single arm phase II trial. Structural and dynamic contrast-enhanced magnet resonance imaging (DCE-MRI) and research blood sampling were performed at baseline and after 12 days. Computed tomography imaging was performed at baseline and post-surgery then every two cycles. The primary endpoint was objective response rate (Response Evaluation Criteria In Solid Tumors [RECIST]) excluding the resected kidney. Secondary endpoints included changes in DCE-MRI of the tumour following pre-surgery sunitinib, overall survival (OS), progression-free survival (PFS), response duration, surgical morbidity/mortality, and toxicity. Translational and imaging endpoints were exploratory. RESULTS: A total of 14 patients received pre-surgery sunitinib, 71% (10/14) took the planned 12 doses. All underwent nephrectomy, and 13 recommenced sunitinib postoperatively. In all, 58.3% (seven of 12) of patients achieved partial or complete response (PR or CR) (95% confidence interval 27.7-84.8%). The median OS was 33.7 months and median PFS was 15.7 months. Amongst those achieving a PR or CR, the median response duration was 8.7 months. No unexpected surgical complications, sunitinib-related toxicities, or surgical delays occurred. Within the translational endpoints, pre-surgical sunitinib significantly increased necrosis, and reduced cluster of differentiation-31 (CD31), Ki67, circulating vascular endothelial growth factor-C (VEGF-C), and transfer constant (KTrans , measured using DCE-MRI; all P < 0.05). There was a trend for improved OS in patients with high baseline plasma VEGF-C expression (P = 0.02). Reduction in radiological tumour volume after pre-surgical sunitinib correlated with high percentage of solid tumour components at baseline (Spearman's coefficient ρ = 0.69, P = 0.02). Conversely, the percentage tumour volume reduction correlated with lower baseline percentage necrosis (coefficient = -0.51, P = 0.03). CONCLUSION: Neoadjuvant studies such as the NeoSun can safely and effectively explore translational biological and imaging endpoints.


Asunto(s)
Antineoplásicos , Carcinoma de Células Renales , Neoplasias Renales , Antineoplásicos/uso terapéutico , Biomarcadores , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/tratamiento farmacológico , Carcinoma de Células Renales/cirugía , Humanos , Indoles/uso terapéutico , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/tratamiento farmacológico , Neoplasias Renales/cirugía , Necrosis/tratamiento farmacológico , Pirroles/uso terapéutico , Sunitinib/uso terapéutico , Factor C de Crecimiento Endotelial Vascular/uso terapéutico
6.
Eur Radiol ; 32(12): 8617-8628, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35678860

RESUMEN

OBJECTIVES: In the Cancer Core Europe Consortium (CCE), standardized biomarkers are required for therapy monitoring oncologic multicenter clinical trials. Multiparametric functional MRI and particularly diffusion-weighted MRI offer evident advantages for noninvasive characterization of tumor viability compared to CT and RECIST. A quantification of the inter- and intraindividual variation occurring in this setting using different hardware is missing. In this study, the MRI protocol including DWI was standardized and the residual variability of measurement parameters quantified. METHODS: Phantom and volunteer measurements (single-shot T2w and DW-EPI) were performed at the seven CCE sites using the MR hardware produced by three different vendors. Repeated measurements were performed at the sites and across the sites including a traveling volunteer, comparing qualitative and quantitative ROI-based results including an explorative radiomics analysis. RESULTS: For DWI/ADC phantom measurements using a central post-processing algorithm, the maximum deviation could be decreased to 2%. However, there is no significant difference compared to a decentralized ADC value calculation at the respective MRI devices. In volunteers, the measurement variation in 2 repeated scans did not exceed 11% for ADC and is below 20% for single-shot T2w in systematic liver ROIs. The measurement variation between sites amounted to 20% for ADC and < 25% for single-shot T2w. Explorative radiomics classification experiments yield better results for ADC than for single-shot T2w. CONCLUSION: Harmonization of MR acquisition and post-processing parameters results in acceptable standard deviations for MR/DW imaging. MRI could be the tool in oncologic multicenter trials to overcome the limitations of RECIST-based response evaluation. KEY POINTS: • Harmonizing acquisition parameters and post-processing homogenization, standardized protocols result in acceptable standard deviations for multicenter MR-DWI studies. • Total measurement variation does not to exceed 11% for ADC in repeated measurements in repeated MR acquisitions, and below 20% for an identical volunteer travelling between sites. • Radiomic classification experiments were able to identify stable features allowing for reliable discrimination of different physiological tissue samples, even when using heterogeneous imaging data.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Neoplasias , Humanos , Imagen de Difusión por Resonancia Magnética/métodos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Neoplasias/diagnóstico por imagen , Europa (Continente) , Reproducibilidad de los Resultados
7.
Magn Reson Med ; 86(1): 320-334, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33645815

RESUMEN

PURPOSE: To develop an improved reconstruction method, k-space subtraction with phase and intensity correction (KSPIC), for highly accelerated, subtractive, non-contrast-enhanced MRA. METHODS: The KSPIC method is based on k-space subtraction of complex raw data. It applies a phase-correction procedure to restore the polarity of negative signals caused by subtraction and an intensity-correction procedure to improve background suppression and thereby sparsity. Ten retrospectively undersampled data sets and 10 groups of prospectively undersampled data sets were acquired in 12 healthy volunteers. The performance of KSPIC was compared with another improved reconstruction based on combined magnitude subtraction, as well as with conventional k-space subtraction reconstruction and magnitude subtraction reconstruction, both using quantitative metrics and using subjective quality scoring. RESULTS: In the quantitative evaluation, KSPIC had the best performance in terms of peak SNR, structural similarity index measure, contrast-to-noise ratio of artery-to-background and sharpness, especially at high acceleration factors. The KSPIC method also had the highest subjective scores for all acceleration factors in terms of vessel delineation, image noise and artifact, and background contamination. The acquisition can be accelerated by a factor of 20 without significant decreases of subjective scores. The optimal size of the phase-correction region was found to be 12-20 pixels in this study. CONCLUSION: Compared with combined magnitude subtraction and conventional reconstructions, KSPIC has the best performance in all of the quantitative and qualitative measurements, permitting good image quality to be maintained up to higher accelerations. The KSPIC method has the potential to further reduce the acquisition time of subtractive MRA for clinical examinations.


Asunto(s)
Angiografía por Resonancia Magnética , Técnica de Sustracción , Artefactos , Arteria Femoral/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Estudios Retrospectivos
8.
Magn Reson Med ; 85(2): 694-708, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32754954

RESUMEN

PURPOSE: To correct the intensity difference of static background signal between bright blood images and dark blood images in subtractive non-contrast-enhanced MR angiography using robust regression, thereby improving static background signal suppression on subtracted angiograms. METHODS: Robust regression (RR), using iteratively reweighted least squares, is used to calculate the regression coefficient of background tissues from a scatter plot showing the voxel intensity of bright blood images versus dark blood images. The weighting function is based on either the Euclidean distance from the estimated regression line or the deviation angle. Results from RR using the deviation angle (RRDA), conventional RR using the Euclidean distance, and ordinary leastsquares regression were compared with reference values determined manually by two observers. Performance was evaluated over studies using different sequences, including 36 thoracic flow-sensitive dephasing data sets, 13 iliac flow-sensitive dephasing data sets, and 26 femoral fresh blood imaging data sets. RESULTS: RR deviation angle achieved robust and accurate performance in all types of images, with small bias, small mean absolute error, and high-correlation coefficients with reference values. Background tissues, such as muscle, veins, and bladder, were suppressed while the vascular signal was preserved. Euclidean distance gave good performance for thoracic and iliac flow-sensitive dephasing, but could not suppress background tissues in femoral fresh blood imaging. Ordinary least squares regression was sensitive to outliers and overestimated regression coefficients in thoracic flow-sensitive dephasing. CONCLUSION: Weighted subtraction using RR was able to acquire the regression coefficients of background signal and improve background suppression of subtractive non-contrast-enhanced MR angiography techniques. RR deviation angle has the most robust and accurate overall performance among three regression methods.


Asunto(s)
Medios de Contraste , Angiografía por Resonancia Magnética , Arteria Femoral , Sensibilidad y Especificidad , Técnica de Sustracción
9.
Eur Radiol ; 31(7): 4908-4917, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33398421

RESUMEN

OBJECTIVES: To assess the multiparametric MRI (mpMRI) appearances of normal peripheral zone (PZ) across age groups in a biopsy-naïve population, where prostate cancer (PCa) was subsequently excluded, and propose a scoring system for background PZ changes. METHODS: This retrospective study included 175 consecutive biopsy-naïve patients (40-74 years) referred with a suspicion of PCa, but with subsequent negative investigations. Patients were grouped by age into categories ≤ 54, 55-59, 60-64, and ≥ 65 years. MpMRI sequences (T2-weighted imaging [T2WI], diffusion-weighted imaging [DWI]/apparent diffusion coefficient [ADC], and dynamic contrast-enhanced imaging [DCE]) were independently evaluated by two uro-radiologists on a proposed 4-point grading scale for background change on each sequence, wherein score 1 mirrored PIRADS-1 change and score 4 represented diffuse background change. Peripheral zone T2WI signal intensity and ADC values were also analyzed for trends relating to age. RESULTS: There was a negative correlation between age and assigned background PZ scores for each mpMRI sequence: T2WI: r = - 0.52, DWI: r = - 0.49, DCE: r = - 0.45, p < 0.001. Patients aged ≤ 54 years had mean scores of 3.0 (T2WI), 2.7 (DWI), and 3.1 (DCE), whilst patients ≥ 65 years had significantly lower mean scores of 1.7, 1.4, and 1.9, respectively. There was moderate inter-reader agreement for all scores (range κ = 0.43-0.58). Statistically significant positive correlations were found for age versus normalized T2WI signal intensity (r = 0.2, p = 0.009) and age versus ADC values (r = 0.33, p = 0.001). CONCLUSION: The normal PZ in younger patients (≤ 54 years) demonstrates significantly lower T2WI signal intensity, lower ADC values, and diffuse enhancement on DCE, which may hinder diagnostic interpretation in these patients. The proposed standardized PZ background scoring system may help convey the potential for diagnostic uncertainty to clinicians. KEY POINTS: • Significant, positive correlations were found between increasing age and higher normalized T2-weighted signal intensity and mean ADC values of the prostatic peripheral zone. • Younger men exhibit lower T2-weighted imaging signal intensity, lower ADC values, and diffuse enhancement on dynamic contrast-enhanced imaging, which may hinder MRI interpretation. • A scoring system is proposed which aims towards a standardized assessment of the normal background PZ. This may help convey the potential for diagnostic uncertainty to clinicians.


Asunto(s)
Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata , Anciano , Imagen de Difusión por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Estudios Retrospectivos
10.
Magn Reson Med ; 84(2): 686-697, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31961969

RESUMEN

PURPOSE: Imaging carotid artery plaques to identify features of vulnerability typically requires a multicontrast MRI protocol. The identification of regions of inflammation with ultrasmall superparamagnetic iron oxide (USPIO) nanoparticles requires separate pre- and postcontrast scans. We propose a method of joint water-fat separation and quantitative susceptibility mapping (QSM) to aid classification of atherosclerotic plaques and offer a positive contrast mechanism in USPIO-imaging. METHODS: Ten healthy volunteers (3 women and 7 men; aged, 30.7 ± 10.7 years) were imaged at 1.5T to develop an acquisition and postprocessing protocol. Five patients (1 woman and 4 men; mean age, 71 ± 7.5 years) with moderate to severe luminal stenosis were imaged pre- and postadministration of a USPIO contrast agent. We used a multiecho gradient echo acquisition to perform water/fat separation and subsequently QSM. The results were compared with a conventional multicontrast MRI protocol, CT images, and histopathology data. RESULTS: In the volunteer scans, a multiecho gradient echo acquisition with bipolar readout gradients demonstrated to be a reliable acquisition methodology to produce high-quality susceptibility maps in conjunction with the proposed postprocessing methodology. In the patient study, water/fat separation provided a tool to identify lipid-rich necrotic cores and QSM provided a qualitative and quantitative evaluation of plaque features and positive contrast when evaluating USPIO uptake. Plaque calcification could be identified by strong diamagnetism (-1.27 ± 0.71 ppm), while USPIO uptake demonstrated a strong paramagnetism (1.32 ± 0.61 ppm). CONCLUSION: QSM was able to identify multiple plaque features in a single acquisition, providing positive contrast for plaques demonstrating USPIO uptake and negative contrast for calcification.


Asunto(s)
Estenosis Carotídea , Nanopartículas de Magnetita , Anciano , Estenosis Carotídea/diagnóstico por imagen , Medios de Contraste , Dextranos , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Agua
11.
Magn Reson Med ; 83(6): 2243-2252, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31737935

RESUMEN

PURPOSE: To compare prostate diffusional kurtosis imaging (DKI) metrics generated using phase-corrected real data with those generated using magnitude data with and without noise compensation (NC). METHODS: Diffusion-weighted images were acquired at 3T in 16 prostate cancer patients, measuring 6 b-values (0-1500 s/mm2 ), each acquired with 6 signal averages along 3 diffusion directions, with noise-only images acquired to allow NC. In addition to conventional magnitude averaging, phase-corrected real data were averaged in an attempt to reduce rician noise-bias, with a range of phase-correction low-pass filter (LPF) sizes (8-128 pixels) tested. Each method was also tested using simulations. Pixelwise maps of apparent diffusion (D) and apparent kurtosis (K) were calculated for magnitude data with and without NC and phase-corrected real data. Average values were compared in tumor, normal transition zone (NTZ), and normal peripheral zone (NPZ). RESULTS: Simulations indicated LPF size can strongly affect K metrics, where 64-pixel LPFs produced accurate metrics. Relative to metrics estimated from magnitude data without NC, median NC K were lower (P < 0.0001) by 6/11/8% in tumor/NPZ/NTZ, 64-LPF real-data K were lower (P < 0.0001) by 4/10/7%, respectively. CONCLUSION: Compared with magnitude data with NC, phase-corrected real data can produce similar K, although the choice of phase-correction LPF should be chosen carefully.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Neoplasias de la Próstata , Difusión , Imagen de Difusión Tensora , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen
12.
Radiology ; 293(2): 374-383, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31573402

RESUMEN

Background Treatment of advanced epithelial ovarian cancer results in a relapse rate of 75%. Early markers of response would enable optimization of management and improved outcome in both primary and recurrent disease. Purpose To assess the apparent diffusion coefficient (ADC), derived from diffusion-weighted MRI, as an indicator of response, progression-free survival (PFS), and overall survival. Materials and Methods This prospective multicenter trial (from 2012-2016) recruited participants with stage III or IV ovarian, primary peritoneal, or fallopian tube cancer (newly diagnosed, cohort one; relapsed, cohort two) scheduled for platinum-based chemotherapy, with interval debulking surgery in cohort one. Cohort one underwent two baseline MRI examinations separated by 0-7 days to assess ADC repeatability; an additional MRI was performed after three treatment cycles. Cohort two underwent imaging at baseline and after one and three treatment cycles. ADC changes in responders and nonresponders were compared (Wilcoxon rank sum tests). PFS and overall survival were assessed by using a multivariable Cox model. Results A total of 125 participants (median age, 63.3 years [interquartile range, 57.0-70.7 years]; 125 women; cohort one, n = 47; cohort two, n = 78) were included. Baseline ADC (range, 77-258 × 10-5mm2s-1) was repeatable (upper and lower 95% limits of agreement of 12 × 10-5mm2s-1 [95% confidence interval {CI}: 6 × 10-5mm2s-1 to 18 × 10-5mm2s-1] and -15 × 10-5mm2s-1 [95% CI: -21 × 10-5mm2s-1 to -9 × 10-5mm2s-1]). ADC increased in 47% of cohort two after one treatment cycle, and in 58% and 53% of cohorts one and two, respectively, after three cycles. Percentage change from baseline differed between responders and nonresponders after three cycles (16.6% vs 3.9%; P = .02 [biochemical response definition]; 19.0% vs 6.2%; P = .04 [radiologic definition]). ADC increase after one cycle was associated with longer PFS in cohort two (adjusted hazard ratio, 0.86; 95% CI: 0.75, 0.98; P = .03). ADC change was not indicative of overall survival for either cohort. Conclusion After three cycles of platinum-based chemotherapy, apparent diffusion coefficient (ADC) changes are indicative of response. After one treatment cycle, increased ADC is indicative of improved progression-free survival in relapsed disease. Published under a CC BY 4.0 license. Online supplemental material is available for this article.


Asunto(s)
Carcinoma Epitelial de Ovario/diagnóstico por imagen , Carcinoma Epitelial de Ovario/terapia , Imagen de Difusión por Resonancia Magnética/métodos , Anciano , Biomarcadores de Tumor/análisis , Carcinoma Epitelial de Ovario/patología , Terapia Combinada , Femenino , Humanos , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Estadificación de Neoplasias , Estudios Prospectivos , Tasa de Supervivencia
13.
Magn Reson Med ; 81(3): 1769-1783, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30444041

RESUMEN

PURPOSE: To evaluate the performance of acceleration-dependent vascular anatomy for non-contrast-enhanced MR venography (ADVANCE-MRV) in femoral veins and to investigate whether venous signal uniformity can be improved by applying multiple acquisitions with different flow suppressions or multiple flow suppressions in 1 acquisition. METHODS: The ADVANCE-MRV method uses flow-sensitized modules to acquire a dark-artery image set and a dark-artery vein set, which are subsequently subtracted. Ten healthy volunteers were imaged using the ADVANCE-MRV sequence with improved venous suppression uniformity in the dark-artery vein images achieved by applying multiple flow suppressions in the same acquisition or by combining multiple images acquired with different flow suppressions. The performance of the improved technique was also evaluated in 13 patients with lower-limb deep venous thrombosis. RESULTS: Multiple-preparation and multiple-acquisition approaches all improved venous signal uniformity and reduced the signal void artifacts observed in the original ADVANCE-MRV images. The multiple-acquisition approaches achieved excellent blood signal uniformity and intensity, albeit at the cost of an increase in the total acquisition time. The double-preparation approach demonstrated good performance in all measurements, providing a good compromise between signal uniformity and acquisition time. The blood signal spatial variation and its variation using different gradient amplitudes were reduced by 20% and 29%. All patient images showed uniform and bright venous signal in nonoccluded sections of vein. CONCLUSION: The enhanced ADVANCE-MRV methods substantially improved signal uniformity in healthy volunteers and patients with known deep venous thrombosis. The double-preparation approach gave good-quality femoral vein images, providing improved venous signal uniformity without increasing acquisition time in comparison to the original sequence.


Asunto(s)
Extremidad Inferior/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Algoritmos , Arterias/diagnóstico por imagen , Simulación por Computador , Femenino , Vena Femoral/diagnóstico por imagen , Voluntarios Sanos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Flebografía , Vena Poplítea/diagnóstico por imagen , Reproducibilidad de los Resultados , Venas/diagnóstico por imagen , Trombosis de la Vena/diagnóstico por imagen , Adulto Joven
14.
Eur Radiol ; 29(10): 5559-5566, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30888488

RESUMEN

PURPOSE: This prospective study evaluated the use of vascular, extracellular and restricted diffusion for cytometry in tumours (VERDICT) MRI to investigate the tissue microstructure in glioma. VERDICT-derived parameters were correlated with both histological features and tumour subtype and were also used to explore the peritumoural region. METHODS: Fourteen consecutive treatment-naïve patients (43.5 years ± 15.1 years, six males, eight females) with suspected glioma underwent diffusion-weighted imaging including VERDICT modelling. Tumour cell radius and intracellular and combined extracellular/vascular volumes were estimated using a framework based on linearisation and convex optimisation. An experienced neuroradiologist outlined the peritumoural oedema, enhancing tumour and necrosis on T2-weighted imaging and contrast-enhanced T1-weighted imaging. The same regions of interest were applied to the co-registered VERDICT maps to calculate the microstructure parameters. Pathology sections were analysed with semi-automated software to measure cellularity and cell size. RESULTS: VERDICT parameters were successfully calculated in all patients. The imaging-derived results showed a larger intracellular volume fraction in high-grade glioma compared to low-grade glioma (0.13 ± 0.07 vs. 0.08 ± 0.02, respectively; p = 0.05) and a trend towards a smaller extracellular/vascular volume fraction (0.88 ± 0.07 vs. 0.92 ± 0.04, respectively; p = 0.10). The conventional apparent diffusion coefficient was higher in low-grade gliomas compared to high-grade gliomas, but this difference was not statistically significant (1.22 ± 0.13 × 10-3 mm2/s vs. 0.98 ± 0.38 × 10-3 mm2/s, respectively; p = 0.18). CONCLUSION: This feasibility study demonstrated that VERDICT MRI can be used to explore the tissue microstructure of glioma using an abbreviated protocol. The VERDICT parameters of tissue structure correlated with those derived on histology. The method shows promise as a potential test for diagnostic stratification and treatment response monitoring in the future. KEY POINTS: • VERDICT MRI is an advanced diffusion technique which has been correlated with histopathological findings obtained at surgery from patients with glioma in this study. • The intracellular volume fraction measured with VERDICT was larger in high-grade tumours compared to that in low-grade tumours. • The results were complementary to measurements from conventional diffusion-weighted imaging, and the technique could be performed in a clinically feasible timescale.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Glioma/diagnóstico por imagen , Adulto , Anciano , Neoplasias Encefálicas/patología , Imagen de Difusión por Resonancia Magnética/métodos , Estudios de Factibilidad , Femenino , Glioma/patología , Humanos , Angiografía por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Estudios Prospectivos , Reproducibilidad de los Resultados , Adulto Joven
15.
Eur Radiol ; 28(8): 3141-3150, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29222677

RESUMEN

OBJECTIVE: To evaluate diffusion kurtosis imaging (DKI) and magnetisation transfer imaging (MTI) compared to standard MRI for prostate cancer assessment in a re-biopsy population. METHODS: Thirty-patients were imaged at 3 T including DKI (Kapp and Dapp) with b-values 150/450/800/1150/1500 s/mm2 and MTI performed with and without MT saturation. Patients underwent transperineal biopsy based on prospectively defined MRI targets. Receiver-operating characteristic (ROC) analyses assessed the parameters and Wilcoxon-signed ranked test assessed relationships between metrics. RESULTS: Twenty patients had ≥ 1 core positive for cancer in a total of 26 MRI targets (Gleason 3+3 in 8, 3+4 in 12, ≥ 4+3 in 6): 13 peripheral (PZ) and 13 transition zone (TZ). The apparent diffusion coefficient (ADC) and Dapp were significantly lower and the Kapp and MT ratio (MTR) significantly higher in tumour versus benign tissue (all p ≤ 0.005); ROC values 0.767-1.000. Normal TZ had: lower ADC and Dapp and higher Kapp and MTR compared to normal PZ. MTR showed a moderate correlation to Kapp (r = 0.570) and Dapp (r = -0.537) in normal tissue but a poor correlation in tumours. No parameter separated low-grade (Gleason 3+3) from high-grade (≥ 3+4) disease for either PZ (p = 0.414-0.825) or TZ (p = 0.148-0.825). CONCLUSION: ADC, Dapp, Kapp and MTR all distinguished benign tissue from tumour, but none reliably differentiated low- from high-grade disease. KEY POINTS: • MTR was significantly higher in PZ and TZ tumours versus normal tissue • K app was significantly lower and D app higher for PZ and TZ tumours • There was no incremental value for DKI/MTI over mono-exponential ADC parameters • No parameter could consistently differentiate low-grade (Gleason 3+3) from high-grade (≥ 3+4) disease • Divergent MTR/DKI values in TZ tumours suggests they offer different functional information.


Asunto(s)
Neoplasias de la Próstata/patología , Anciano , Imagen de Difusión por Resonancia Magnética/métodos , Imagen de Difusión Tensora/métodos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Biopsia Guiada por Imagen/métodos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Retratamiento
16.
Eur J Appl Physiol ; 118(7): 1415-1426, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29713818

RESUMEN

BACKGROUND: Right ventricular (RV) dysfunction and heart failure with preserved ejection fraction may contribute to exercise intolerance in obesity. To further define RV exercise responses, we investigated RV-arterial coupling in obesity with and without development of exercise pulmonary venous hypertension (ePVH). METHODS: RV-arterial coupling defined as RV end-systolic elastance/pulmonary artery elastance (Ees/Ea) was calculated from invasive cardiopulmonary exercise test data in 6 controls, 8 obese patients without ePVH (Obese-ePVH) and 8 obese patients with ePVH (Obese+ePVH) within a larger series. ePVH was defined as a resting pulmonary arterial wedge pressure < 15 mmHg but ≥ 20 mmHg on exercise. Exercise haemodynamics were further evaluated in 18 controls, 20 Obese-ePVH and 17 Obese+ePVH patients. RESULTS: Both Obese-ePVH and Obese+ePVH groups developed exercise RV-arterial uncoupling (peak Ees/Ea = 1.45 ± 0.26 vs 0.67 ± 0.18 vs 0.56 ± 0.11, p < 0.001, controls vs Obese-ePVH vs Obese+ePVH respectively) with higher peak afterload (peak Ea = 0.31 ± 0.07 vs 0.75 ± 0.32 vs 0.88 ± 0.62 mL/mmHg, p = 0.043) and similar peak contractility (peak Ees = 0.50 ± 0.16 vs 0.45 ± 0.22 vs 0.48 ± 0.17 mL/mmHg, p = 0.89). RV contractile reserve was highest in controls (ΔEes = 224 ± 80 vs 154 ± 39 vs 141 ± 34% of baseline respectively, p < 0.001). Peak Ees/Ea correlated with peak pulmonary vascular compliance (PVC, r = 0.53, p = 0.02) but not peak pulmonary vascular resistance (PVR, r = - 0.20, p = 0.46). In the larger cohort, Obese+ePVH patients on exercise demonstrated higher right atrial pressure, lower cardiac output and steeper pressure-flow responses. BMI correlated with peak PVC (r = - 0.35, p = 0.04) but not with peak PVR (r = 0.24, p = 0.25). CONCLUSIONS: Exercise RV-arterial uncoupling and reduced RV contractile reserve further characterise obesity-related exercise intolerance. RV dysfunction in obesity may develop independent of exercise LV filling pressures.


Asunto(s)
Función Atrial , Tolerancia al Ejercicio , Hipertensión Pulmonar/fisiopatología , Contracción Miocárdica , Obesidad/fisiopatología , Función Ventricular , Anciano , Circulación Coronaria , Ejercicio Físico , Femenino , Humanos , Hipertensión Pulmonar/etiología , Masculino , Persona de Mediana Edad , Obesidad/complicaciones , Obesidad/diagnóstico por imagen , Circulación Pulmonar
17.
J Magn Reson Imaging ; 45(6): 1846-1853, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-27902859

RESUMEN

PURPOSE: To evaluate the diagnostic performance of velocity- and acceleration-sensitized noncontrast-enhanced magnetic resonance angiography (NCE-MRA) of the infrageniculate arteries using contrast-enhanced MRA (CE-MRA) as a reference standard. MATERIALS AND METHODS: Twenty-four patients with symptoms of peripheral arterial disease were recruited. Each patient's infrageniculate arterial tree was examined using a velocity-dependent flow-sensitized dephasing (VEL-FSD) technique, an acceleration-dependent (ACC-FSD) technique, and our conventional CE-MRA technique performed at 1.5T. The images were independently reviewed by two experienced vascular radiologists, who evaluated each vessel segment to assess visibility, diagnostic confidence, venous contamination, and detection of pathology. RESULTS: In all, 432 segments were evaluated by each of the three techniques by each reader in total. Overall diagnostic confidence was rated as moderate or high in 98.5% of segments with CE-MRA, 92.1% with VEL-FSD, and 79.9% with ACC-FSD. No venous contamination was seen in 96% of segments with CE-MRA, 72.2% with VEL-FSD, and 85.8% with ACC-FSD. Per-segment, per-limb, and per-patient sensitivities for detecting significant stenotic disease were 63.4%, 73%, and 92%, respectively, for ACC-FSD, and 65.3%, 87.2%, and 96% for VEL-FSD, and as such no significant statistical change was detected using McNemar's chi-squared test with P-values of 1.00, 0.13, and 0.77 obtained, respectively. CONCLUSION: Flow-dependent NCE-MRA techniques may have a role to play in evaluation of patients with peripheral vascular disease. Increased sensitivity of a velocity-based technique compared to an acceleration-based technique comes at the expense of greater venous contamination. LEVEL OF EVIDENCE: 2J. Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;45:1846-1853.


Asunto(s)
Aumento de la Imagen/métodos , Pierna/irrigación sanguínea , Pierna/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos , Enfermedad Arterial Periférica/diagnóstico por imagen , Procesamiento de Señales Asistido por Computador , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Pierna/patología , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/patología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
18.
Eur Radiol ; 27(7): 2726-2736, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27798751

RESUMEN

OBJECTIVES: To assess the feasibility of the mono-exponential, bi-exponential and stretched-exponential models in evaluating response of breast tumours to neoadjuvant chemotherapy (NACT) at 3 T. METHODS: Thirty-six female patients (median age 53, range 32-75 years) with invasive breast cancer undergoing NACT were enrolled for diffusion-weighted MRI (DW-MRI) prior to the start of treatment. For assessment of early response, changes in parameters were evaluated on mid-treatment MRI in 22 patients. DW-MRI was performed using eight b values (0, 30, 60, 90, 120, 300, 600, 900 s/mm2). Apparent diffusion coefficient (ADC), tissue diffusion coefficient (D t), vascular fraction (ƒ), distributed diffusion coefficient (DDC) and alpha (α) parameters were derived. Then t tests compared the baseline and changes in parameters between response groups. Repeatability was assessed at inter- and intraobserver levels. RESULTS: All patients underwent baseline MRI whereas 22 lesions were available at mid-treatment. At pretreatment, mean diffusion coefficients demonstrated significant differences between groups (p < 0.05). At mid-treatment, percentage increase in ADC and DDC showed significant differences between responders (49 % and 43 %) and non-responders (21 % and 32 %) (p = 0.03, p = 0.04). Overall, stretched-exponential parameters showed excellent repeatability. CONCLUSION: DW-MRI is sensitive to baseline and early treatment changes in breast cancer using non-mono-exponential models, and the stretched-exponential model can potentially monitor such changes. KEY POINTS: • Baseline diffusion coefficients demonstrated significant differences between complete pathological responders and non-responders. • Increase in ADC and DDC at mid-treatment can discriminate responders and non-responders. • The ƒ fraction at mid-treatment decreased in responders whereas increased in non-responders. • The mono- and stretched-exponential models showed excellent inter- and intrarater repeatability. • Treatment effects can potentially be assessed by non-mono-exponential diffusion models.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Neoplasias de la Mama/tratamiento farmacológico , Quimioterapia Adyuvante , Terapia Neoadyuvante/métodos , Adulto , Anciano , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Ciclofosfamida/administración & dosificación , Imagen de Difusión por Resonancia Magnética , Docetaxel , Epirrubicina/administración & dosificación , Estudios de Factibilidad , Femenino , Fluorouracilo/administración & dosificación , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Reproducibilidad de los Resultados , Taxoides/administración & dosificación
19.
Magn Reson Med ; 75(4): 1708-16, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25995019

RESUMEN

PURPOSE: Ultrasound-guided fine needle aspirate cytology fails to diagnose many malignant thyroid nodules; consequently, patients may undergo diagnostic lobectomy. This study assessed whether textural analysis (TA) could noninvasively stratify thyroid nodules accurately using diffusion-weighted MRI (DW-MRI). METHODS: This multi-institutional study examined 3T DW-MRI images obtained with spin echo echo planar imaging sequences. The training data set included 26 patients from Cambridge, United Kingdom, and the test data set included 18 thyroid cancer patients from Memorial Sloan Kettering Cancer Center (New York, New York, USA). Apparent diffusion coefficients (ADCs) were compared over regions of interest (ROIs) defined on thyroid nodules. TA, linear discriminant analysis (LDA), and feature reduction were performed using the 21 MaZda-generated texture parameters that best distinguished benign and malignant ROIs. RESULTS: Training data set mean ADC values were significantly different for benign and malignant nodules (P = 0.02) with a sensitivity and specificity of 70% and 63%, respectively, and a receiver operator characteristic (ROC) area under the curve (AUC) of 0.73. The LDA model of the top 21 textural features correctly classified 89/94 DW-MRI ROIs with 92% sensitivity, 96% specificity, and an AUC of 0.97. This algorithm correctly classified 16/18 (89%) patients in the independently obtained test set of thyroid DW-MRI scans. CONCLUSION: TA classifies thyroid nodules with high sensitivity and specificity on multi-institutional DW-MRI data sets. This method requires further validation in a larger prospective study. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Glándula Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/diagnóstico por imagen , Adulto , Anciano , Área Bajo la Curva , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
20.
J Magn Reson Imaging ; 44(3): 739-44, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-26892734

RESUMEN

PURPOSE: To evaluate the utility of oxygen challenge and report on temporal changes in blood oxygenation level-dependent (BOLD) contrast in normal liver, hepatocellular carcinoma (HCC) and background fibrosis. MATERIALS AND METHODS: Eleven volunteers (nine male and two female, mean age 33.5, range 27-41 years) and 10 patients (nine male and one female, mean age 68.9, range 56-87 years) with hepatocellular carcinoma on a background of diffuse liver disease were recruited. Imaging was performed on a 3T system using a multiphase, multiecho, fast gradient echo sequence. Oxygen was administered via a Hudson mask after 2 minutes of free-breathing. Paired t-tests were performed to determine if the mean pre- and post-O2 differences were statistically significant. RESULTS: In patients with liver fibrosis (n = 8) the change in T2* following O2 administration was elevated (0.88 ± 0.582 msec, range 0.03-1.69 msec) and the difference was significant (P = 0.004). The magnitude of the BOLD response in patients with HCC (n = 10) was larger, however the response was more variable (1.07 ± 1.458 msec, range -0.93-3.26 msec), and the difference was borderline significant (P = 0.046). The BOLD response in the volunteer cohort was not significant (P = 0.121, 0.59 ± 1.162 msec, range -0.81-2.44 msec). CONCLUSION: This work demonstrates that the BOLD response following oxygen challenge within cirrhotic liver is consistent with a breakdown in vascular autoregulatory mechanisms. Similarly, the elevated BOLD response within HCC is consistent with the abnormal capillary vasculature within tumors and the arterialization of the blood supply. Our results suggest that oxygen challenge may prove a viable BOLD contrast mechanism in the liver. J. Magn. Reson. Imaging 2016;44:739-744.


Asunto(s)
Carcinoma Hepatocelular/metabolismo , Cirrosis Hepática/metabolismo , Imagen por Resonancia Magnética/métodos , Oxígeno/metabolismo , Circulación Renal , Hipoxia Tumoral , Adulto , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Carcinoma Hepatocelular/complicaciones , Carcinoma Hepatocelular/diagnóstico por imagen , Femenino , Humanos , Cirrosis Hepática/diagnóstico por imagen , Masculino , Tasa de Depuración Metabólica , Persona de Mediana Edad , Consumo de Oxígeno , Factores de Tiempo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA