Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Endoscopy ; 44(1): 27-31, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22125197

RESUMEN

BACKGROUND: Cold polypectomy techniques (without electrocautery) by means of biopsy forceps or snare are widely adopted for the removal of subcentimetric polyps. However, few data are available on the safety of this approach. The aim of this study was to assess the safety of cold polypectomy for subcentimetric polyps, as well as the rate of advanced neoplasia in these lesions. PATIENTS AND METHODS: In a prospective multicenter trial, consecutive patients with at least one < 10-mm polyp at colonoscopy were prospectively included. All of the < 10-mm polyps detected within the study period were removed by cold polypectomy. The rates of immediate or delayed bleeding and other complications were assessed at 7 and 30 days after cold polypectomy by telephone calls. The rate of advanced histology was also assessed. Predictive variables of postpolypectomy bleeding or advanced neoplasia were identified by multivariate analysis. RESULTS: A total of 1015 < 10-mm polyps in 823 patients (15.5 % on antiplatelet agents) were removed. Of these, 822 (81 %) were ≤ 5 mm and 193 (19 %) were 6 - 9 mm. Immediate postpolypectomy bleeding occurred in 18 patients, corresponding to a per-patient and per-polyp bleeding rate of 2.2 % (95 % confidence interval [CI] 1.2 % - 3.2 %) and 1.8 % (95 %CI 1 % - 2.6 %), respectively. Therapy with antiplatelet agents (odds ratio [OR] 4; 95 %CI 1.5 - 10.6) and larger polyp size (OR 2; 95 %CI 1.1 - 6.9) were independent predictors of bleeding. Bleeding was successfully treated by endoscopic hemostasis in all cases and required no further medical intervention. Advanced neoplasia prevalence in polyps ≤ 5 mm was as high as 8.7 %. CONCLUSIONS: The results from this study showed the high safety of a cold polypectomy approach for subcentimetric polyps. This was due to the low rate of postpolypectomy bleeding and to the high efficacy of endoscopic hemostasis in its treatment. The high rate of advanced neoplasia in polyps ≤ 5 mm should prompt some caution on the management of these lesions following detection at computed tomography colonography or colon capsule endoscopy.


Asunto(s)
Neoplasias del Colon/diagnóstico , Pólipos del Colon/cirugía , Hemorragia Gastrointestinal/etiología , Hemorragia Posoperatoria/etiología , Anciano , Pérdida de Sangre Quirúrgica , Neoplasias del Colon/patología , Pólipos del Colon/patología , Colonoscopía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/efectos adversos , Factores de Riesgo
2.
Clin Ter ; 170(1): e1-e3, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30789190

RESUMEN

Radium 223 dichloride (Ra223) is the only targeted alpha therapy able to extend survival in patients with bone metastases from prostate cancer. Mechanism of action and data currently available focused mainly on osteoblastic metastases from prostate cancer. Phase 1 and 2 trials documented a clinical efficacy also in breast cancer patients with predominately bone disease, highlighting a reduction in alkaline phosphatase and other bone biomarkers. In our institution, a patient with breast cancer affected by osteolytic metastases was treated with off-label use of Ra223. Our patient had a good treatment compliance and up to now she has not been revealed the presence of SSE or hematological complications. Our preliminary experience shows that Ra223 may play a critical role to bone metastates in patients with breast cancer.


Asunto(s)
Antineoplásicos/uso terapéutico , Neoplasias Óseas/tratamiento farmacológico , Neoplasias Óseas/secundario , Neoplasias de la Mama/patología , Radio (Elemento)/uso terapéutico , Femenino , Humanos , Radioisótopos/uso terapéutico
3.
Aliment Pharmacol Ther ; 33(6): 697-706, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21255060

RESUMEN

BACKGROUND: Accuracy of intraepithelial lymphocytes counts for diagnosing mild enteropathy coeliac disease in absence of villous atrophy can be limited by inappropriate controls included in the studies. AIM: To determine the diagnostic accuracy of intraepithelial lymphocytes counts utilising controls lacking HLA coeliac disease-associated alleles. METHODS: Intraepithelial lymphocytes counting at villus tip and per 100 enterocytes was performed at haematoxylin and eosin (H&E) and CD3-stainings in: 29 cases (21 with potential coeliac disease and 8 affected by latent coeliac disease) representing the patient population and 14 noncoeliac controls lacking HLA-DQ2/DQ8 alleles. RESULTS: Threshold (mean+2 s.d.) of duodenal intraepithelial lymphocytes at villus tip and per 100 enterocytes in noncoeliac controls was respectively: 3.5 and 18 at H&E, 3.2 and 17 following CD3-staining. Considering the whole patient population, the sensitivity of tip intraepithelial lymphocytes in detecting mild enteropathy coeliac disease was 90% (95% CI=72.6-97.8) both at H&E and CD3-stainings. The sensitivity of intraepithelial lymphocytes per 100 enterocytes was 93% (95% CI=77.2-99.2) both at H&E and CD3-staining. Specificity of both intraepithelial lymphocytes counts was 100% (95% CI=76.8-100). Using a threshold of 25 intraepithelial lymphocytes per 100 enterocytes could miss 59% of cases at H&E and 48% following CD3-staining. CONCLUSIONS: Intraepithelial lymphocytes counts are diagnostic feasible tools to detect mild enteropathy coeliac disease. Threshold of duodenal intraepithelial lymphocytes may be lower than currently accepted.


Asunto(s)
Enfermedad Celíaca/diagnóstico , Duodeno/patología , Mucosa Intestinal/patología , Adolescente , Adulto , Anciano , Biopsia , Enfermedad Celíaca/patología , Niño , Preescolar , Enterocitos/patología , Femenino , Prueba de Histocompatibilidad , Humanos , Recuento de Linfocitos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA