Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38837058

RESUMEN

PURPOSE: We conducted a cost-effectiveness analysis in which we compared a preoperative [18F]Fluorocholine PET/CT-based one-stop-shop imaging strategy with current best practice in which [18F]Fluorocholine PET/CT is only recommended after negative or inconclusive [99mTc]Tc-methoxy isobutyl isonitrile SPECT/CT for patients suffering from primary hyperparathyroidism. We investigated whether the one-stop-shop strategy performs as well as current best practice but at lower costs. METHODS: We developed a cohort-level state transition model to evaluate both imaging strategies respecting an intraoperative parathyroid hormone monitored treatment setting as well as a traditional treatment setting. The model reflects patients' hospital journeys after biochemically diagnosed primary hyperparathyroidism. A cycle length of twelve months and a lifetime horizon were used. We conducted probabilistic analyses simulating 50,000 cohorts to assess joint parameter uncertainty. The incremental net monetary benefit and cost for each quality-adjusted life year were estimated. Furthermore, threshold analyses regarding the tariff of [18F]Fluorocholine PET/CT and the sensitivity of [99mTc]Tc-methoxy isobutyl isonitrile SPECT/CT were performed. RESULTS: The simulated long-term health effects and costs were similar for both imaging strategies. Accordingly, there was no incremental net monetary benefit and the one-stop-shop strategy did not result in lower costs. These results applied to both treatment settings. The threshold analysis indicated that a tariff of €885 for [18F]Fluorocholine PET/CT was required to be cost-effective compared to current best practice. CONCLUSION: Both preoperative imaging strategies can be used interchangeably. Daily clinical practice grounds such as available local resources and patient preferences should inform policy-making on whether a hospital should implement the one-stop-shop imaging strategy.

2.
Q J Nucl Med Mol Imaging ; 67(2): 122-129, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36756935

RESUMEN

INTRODUCTION: Primary hyperparathyroidism (pHPT) is a common endocrine disorder caused by an autonomous overproduction of parathyroid hormone (PTH) by a parathyroid gland. Over the last decade, 18F-choline (FCH) PET has emerged as a highly performant imaging technique for guiding parathyroidectomy. As cure is the goal of surgery, the main aims of this study were to summarize patient-based sensitivity, positive predictive value (PPV), and cure rate of FCH PET guided surgery in the surgical management of pHPT. EVIDENCE ACQUISITION: We conducted a systematic review and metaanalysis according to the PRISMA Guidelines. A literature search was performed in the PubMed, Web of Science and Cochrane databases, last updated November 2022. Original articles on choline PET in patients with pHPT mentioning patient-based sensitivity, PPV and cure rate were retained. Quality of included studies was assessed using the QUADAS-2 Tool. Patient-based sensitivity, PPV and cure rate were pooled by using a random-effects model. EVIDENCE SYNTHESIS: Twenty-three studies including 1716 patients were included for quantitative assessment. FCH PET showed a pooled patient-based sensitivity of 93.8% (95% CI: 89.8-96.3) and PPV of 97% (95% CI: 92.8-98.8) in patients with pHPT. Parathyroid surgery was performed in 1129 patients. The pooled cure rate of PET-guided surgery was 92.8% (95% CI: 87.4-96.0). Heterogeneity was shown to be moderate for all effect sizes. CONCLUSIONS: FCH PET showed a high patient-based sensitivity, PPV and cure rate of PET guided surgery in patients with pHPT.


Asunto(s)
Hiperparatiroidismo Primario , Humanos , Hiperparatiroidismo Primario/diagnóstico por imagen , Hiperparatiroidismo Primario/cirugía , Glándulas Paratiroides/cirugía , Colina , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos
3.
Eur J Nucl Med Mol Imaging ; 49(11): 3750-3760, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35593925

RESUMEN

PURPOSE: We investigated whether artificial intelligence (AI)-based denoising halves PET acquisition time in digital PET/CT. METHODS: One hundred ninety-five patients referred for [18F]FDG PET/CT were prospectively included. Body PET acquisitions were performed in list mode. Original "PET90" (90 s/bed position) was compared to reconstructed ½-duration PET (45 s/bed position) with and without AI-denoising, "PET45AI and PET45". Denoising was performed by SubtlePET™ using deep convolutional neural networks. Visual global image quality (IQ) 3-point scores and lesion detectability were evaluated. Lesion maximal and peak standardized uptake values using lean body mass (SULmax and SULpeak), metabolic volumes (MV), and liver SULmean were measured, including both standard and EARL1 (European Association of Nuclear Medicine Research Ltd) compliant SUL. Lesion-to-liver SUL ratios (LLR) and liver coefficients of variation (CVliv) were calculated. RESULTS: PET45 showed mediocre IQ (scored poor in 8% and moderate in 68%) and lesion concordance rate with PET90 (88.7%). In PET45AI, IQ scores were similar to PET90 (P = 0.80), good in 92% and moderate in 8% for both. The lesion concordance rate between PET90 and PET45AI was 836/856 (97.7%), with 7 lesions (0.8%) only detected in PET90 and 13 (1.5%) exclusively in PET45AI. Lesion EARL1 SULpeak was not significantly different between both PET (P = 0.09). Lesion standard SULpeak, standard and EARL1 SULmax, LLR and CVliv were lower in PET45AI than in PET90 (P < 0.0001), while lesion MV and liver SULmean were higher (P < 0.0001). Good to excellent intraclass correlation coefficients (ICC) between PET90 and PET45AI were observed for lesion SUL and MV (ICC ≥ 0.97) and for liver SULmean (ICC ≥ 0.87). CONCLUSION: AI allows [18F]FDG PET duration in digital PET/CT to be halved, while restoring degraded ½-duration PET image quality. Future multicentric studies, including other PET radiopharmaceuticals, are warranted.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Inteligencia Artificial , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones , Radiofármacos
4.
Radiology ; 300(1): E301-E307, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33724061

RESUMEN

Background Early reports show the unequal effect the COVID-19 pandemic might have on men versus women engaged in medical research. Purpose To investigate whether the COVID-19 pandemic has had an impact on scientific publishing by female physicians in medical imaging. Materials and Methods The authors conducted a descriptive bibliometric analysis of the gender of the first and last authors of manuscripts submitted to the top 50 medical imaging journals from March to May 2020 (n = 2480) compared with the same period of the year in 2018 (n = 2238) and 2019 (n = 2355). Manuscript title, date of submission, first and last names of the first and last authors, journal impact factor, and author country of provenance were recorded. The Gender-API software was used to determine author gender. Statistical analysis comprised χ2 tests and multivariable logistic regression. Results Percentages of women listed as first and last authors were 31.6% (1172 of 3711 articles) and 19.3% (717 of 3711 articles), respectively, in 2018-2019 versus 32.3% (725 of 2248 articles) and 20.7% (465 of 2248 articles) in 2020 (P = .61 and P = .21, respectively). For COVID-19-related articles, 35.2% (89 of 253 articles) of first authors and 20.6% (52 of 253 articles) of last authors were women. No associations were found between first- and last-author gender, year of publication, and region of provenance. First and last authorship of high-ranking articles was not in favor of North American women whatever the year (odds ratio [OR], 0.79 [P = .05] and 0.72 [P = .02], respectively). Higher rates of female last authorship of high-ranking articles were observed in Europe (P = .003) and of female first authorship of low-ranking publications in Asia in 2020 (OR, 1.38; 95% CI: 0.98, 1.92; P = .06). Female first and last authorship of COVID-19-related articles was overrepresented for lowest-rank publications (P = .02 and P = .01, respectively). Conclusion One in three first authors and one in five last authors were women in 2018-2019 and 2020, respectively. Although the first 2020 lockdown did not diminish the quantity of women-authored publications, the impact on the quality was variable. ©RSNA, 2021 See also the editorial by Robbins and Khosa in this issue.


Asunto(s)
Autoria , Bibliometría , Investigación Biomédica/estadística & datos numéricos , COVID-19 , Publicaciones Periódicas como Asunto/estadística & datos numéricos , Sexismo/estadística & datos numéricos , Femenino , Humanos , Masculino , Pandemias , Cuarentena , SARS-CoV-2
5.
BMC Endocr Disord ; 21(1): 3, 2021 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-33413316

RESUMEN

BACKGROUND: The common endocrine disorder primary hyperparathyroidism (PHPT) can be cured by surgery. Preoperative localization of parathyroid adenoma (PTA) by imaging is a prerequisite for outpatient minimally invasive parathyroidectomy (MIP). Compared to inpatient bilateral cervical exploration (BCE) which is performed if imaging is inconclusive, MIP is superior in terms of cure and complication rates and less costly. The imaging procedure F18-choline (FCH) PET/CT outperforms Tc99m-sestaMIBI (MIBI) SPECT/CT for PTA localization, but it is much costlier. The aim of this study is to identify the most efficient first-line imaging modality for optimal patient care in PHPT without added cost to society. METHODS: We will conduct a multicenter open diagnostic intervention randomized phase III trial comparing two diagnostic strategies in patients with PHPT: upfront FCH PET/CT versus MIBI SPECT/CT. The primary endpoint is the proportion of patients in whom the first-line imaging method results in successful MIP and cure. Follow-up including biological tests will be performed 1 and 6 months after surgery. The main secondary endpoint is the social cost of both strategies. Other secondary endpoints are as follows: FCH PET/CT and MIBI SPECT/CT diagnostic performance, performance of surgical procedure and complication rate, FCH PET/CT inter- and intra-observer variability and optimization of FCH PET/CT procedure. Fifty-eight patients will be enrolled and randomized 1:1. DISCUSSION: FCH PET/CT is a highly efficient but expensive imaging test for preoperative PTA localization and costs three to four times more than MIBI SPECT/CT. Whether FCH PET/CT improves patient outcomes compared to the reference standard MIBI SPECT/CT is unknown. To justify its added cost, FCH PET/CT-guided parathyroid surgery should lead to improved patient management, resulting in higher cure rates and fewer BCEs and surgical complications. In the previous phase II APACH1 study, we showed that second-line FCH PET/CT led to a cure in 88% of patients with negative or inconclusive MIBI SPECT/CT. BCE could be avoided in 75% of patients and surgical complication rates were low. We therefore hypothesize that upfront FCH PET/CT would improve patient care in PHPT and that the reduction in clinical costs would offset the increase in imaging costs. TRIAL REGISTRATION: NCT04040946 , registered August 1, 2019.  Protocol version Version 2.1 dated from 2020/04/23.


Asunto(s)
Radioisótopos de Flúor/metabolismo , Hiperparatiroidismo Primario/cirugía , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Cirugía Asistida por Computador/métodos , Tecnecio Tc 99m Sestamibi/metabolismo , Tomografía Computarizada de Emisión de Fotón Único/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Ensayos Clínicos Fase III como Asunto , Femenino , Estudios de Seguimiento , Humanos , Hiperparatiroidismo Primario/diagnóstico por imagen , Hiperparatiroidismo Primario/metabolismo , Hiperparatiroidismo Primario/patología , Masculino , Persona de Mediana Edad , Estudios Multicéntricos como Asunto , Pronóstico , Radiofármacos/metabolismo , Ensayos Clínicos Controlados Aleatorios como Asunto , Adulto Joven
6.
Eur J Nucl Med Mol Imaging ; 45(4): 658-666, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29270788

RESUMEN

PURPOSE: To evaluate the sensitivity of F18-choline (FCH) PET/CT for parathyroid adenoma detection prior to surgery in patients with primary hyperparathyroidism and negative or inconclusive cervical ultrasound and Tc99m-sestaMIBI SPECT/CT. METHODS: We conducted a prospective bicentric study (NCT02432599). All patients underwent FCH PET/CT. The result was scored positive, inconclusive or negative. The number of uptakes and their sites were recorded. The FCH PET/CT result guided the surgical procedure (minimally invasive parathyroidectomy, bilateral cervical exploration, or other in case of multiple or ectopic foci). FCH PET/CT results were compared to the surgical and pathological findings and the follow-up. RESULTS: Twenty-five patients were included. Mean calcium and PTH levels prior to surgery were 2.76 ± 0.17 mmol/l and 94.8 ± 37.4 ng/l. Nineteen (76%) FCH PET/CTs were scored positive, 3 (12%) inconclusive and 3 (12%) negative, showing 21 cases of uniglandular disease, including 1 ectopic localization and 1 case of multiglandular (3 foci) disease. Mean lesion size was 13.1 ± 8.6 mm. Twenty-four patients underwent surgery. FCH PET/CT guided surgery in 22 (88%) patients, allowing for 17 minimally invasive parathyroidectomies, 1 bilateral cervical exploration for multifocality and 4 other surgical procedures. Two patients with negative FCH-PET/CT underwent bilateral cervical exploration. When dichotomizing the FCH PET/CT results, thereby classifying the inconclusive FCH PET/CT results as positive, the per lesion and per patient sensitivities were 91.3% (95%CI: 72.0-98.9) and 90.5% (95%CI: 69.6-98.8) and the corresponding positive predictive values were 87.5% (95%CI: 67.6-97.3) and 86.4% (95%CI: 65.1-97.1), respectively. Twenty-one (88%) patients were considered cured after surgery. Their mean calcium level after surgery was 2.36 ± 0.17 mmol/l. CONCLUSIONS: Preoperative FCH PET/CT has a high sensitivity and positive predictive value for parathyroid adenoma detection in patients with primary hyperparathyroidism and negative or inconclusive conventional imaging results. Bilateral cervical exploration could be avoided in the majority (75%) of patients.


Asunto(s)
Hiperparatiroidismo Primario/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Adenoma , Anciano , Colina , Femenino , Radioisótopos de Flúor , Humanos , Hiperparatiroidismo Primario/cirugía , Masculino , Persona de Mediana Edad , Neoplasias de las Paratiroides , Estudios Prospectivos , Radiofármacos , Tecnecio Tc 99m Sestamibi
8.
Eur J Nucl Med Mol Imaging ; 42(13): 2072-82, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26219870

RESUMEN

PURPOSE: Point-spread function (PSF) or PSF + time-of-flight (TOF) reconstruction may improve lesion detection in oncologic PET, but can alter quantitation resulting in variable standardized uptake values (SUVs) between different PET systems. This study aims to validate a proprietary software tool (EQ.PET) to harmonize SUVs across different PET systems independent of the reconstruction algorithm used. METHODS: NEMA NU2 phantom data were used to calculate the appropriate filter for each PSF or PSF+TOF reconstruction from three different PET systems, in order to obtain EANM compliant recovery coefficients. PET data from 517 oncology patients were reconstructed with a PSF or PSF+TOF reconstruction for optimal tumour detection and an ordered subset expectation maximization (OSEM3D) reconstruction known to fulfil EANM guidelines. Post-reconstruction, the proprietary filter was applied to the PSF or PSF+TOF data (PSFEQ or PSF+TOFEQ). SUVs for PSF or PSF+TOF and PSFEQ or PSF+TOFEQ were compared to SUVs for the OSEM3D reconstruction. The impact of potential confounders on the EQ.PET methodology including lesion and patient characteristics was studied, as was the adherence to imaging guidelines. RESULTS: For the 1380 tumour lesions studied, Bland-Altman analysis showed a mean ratio between PSF or PSF+TOF and OSEM3D of 1.46 (95%CI: 0.86-2.06) and 1.23 (95%CI: 0.95-1.51) for SUVmax and SUVpeak, respectively. Application of the proprietary filter improved these ratios to 1.02 (95%CI: 0.88-1.16) and 1.04 (95%CI: 0.92-1.17) for SUVmax and SUVpeak, respectively. The influence of the different confounding factors studied (lesion size, location, radial offset and patient's BMI) was less than 5%. Adherence to the European Association of Nuclear Medicine (EANM) guidelines for tumour imaging was good. CONCLUSION: These data indicate that it is not necessary to sacrifice the superior lesion detection and image quality achieved by newer reconstruction techniques in the quest for harmonizing quantitative comparability between PET systems.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Linfoma no Hodgkin/diagnóstico por imagen , Melanoma/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Anciano , Femenino , Fluorodesoxiglucosa F18 , Humanos , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones/normas , Radiofármacos
9.
Artículo en Inglés | MEDLINE | ID: mdl-38900416

RESUMEN

Importance: Whether F18-choline (FCH) positron emission tomographic (PET)/computed tomographic (CT) scan can replace Tc99m-sestaMIBI (MIBI) single-photon emission (SPE)CT/CT as a first-line imaging technique for preoperative localization of parathyroid adenomas (PTA) in patients with primary hyperparathyroidism (PHPT) is unclear. Objective: To compare first-line FCH PET/CT vs MIBI SPECT/CT for optimal care in patients with PHPT needing parathyroidectomy and to compare the proportions of patients in whom the first-line imaging method resulted in successful minimally invasive parathyroidectomy (MIP) and normalization of calcemia 1 month after surgery. Design, Setting, and Participants: A French multicenter randomized open diagnostic intervention phase 3 trial was conducted. Patients were enrolled from November 2019 to May 2022 and participated up to 6 months after surgery. The study included adults with PHPT and an indication for surgical treatment. Patients with previous parathyroid surgery or multiple endocrine neoplasia type 1 (MEN1) were ineligible. Interventions: Patients were assigned in a 1:1 ratio to receive first-line FCH PET/CT (FCH1) or MIBI SPECT/CT (MIBI1). In the event of negative or inconclusive first-line imaging, they received second-line FCH PET/CT (FCH2) after MIBI1 or MIBI SPECT/CT (MIBI2) after FCH1. All patients underwent surgery under general anesthesia within 12 weeks following the last imaging. Clinical and biologic (serum calcemia and parathyroid hormone levels) assessments were performed 1 and 6 months after surgery. Main Outcomes and Measures: The primary outcome was a true-positive first-line imaging-guided MIP combined with uncorrected serum calcium levels of 2.55 mmol/l or less 1 month after surgery, corresponding to the local upper limit of normality. Results: Overall, 57 patients received FCH1 (n = 29) or MIBI1 (n = 28). The mean (SD) age of patients was 62.8 (12.5) years with 15 male (26%) and 42 female (74%) patients. Baseline patient characteristics were similar between groups. Normocalcemia at 1 month after positive first-line imaging-guided MIP was observed in 23 of 27 patients (85%) in the FCH1 group and 14 of 25 patients (56%) in the MIBI1 group. Sensitivity was 82% (95% CI, 62%-93%) and 63% (95% CI, 42%-80%) for FCH1 and MIBI1, respectively. Follow-up at 6 months with biochemical measures was available in 43 patients, confirming that all patients with normocalcemia at 1 month after surgery still had it at 6 months. No adverse events related to imaging and 4 adverse events related to surgery were reported. Conclusions: This randomized clinical trial found that first-line FCH PET/CT is a suitable and safe replacement for MIBI SPECT/CT. FCH PET/CT leads more patients with PHPT to correct imaging-guided MIP and normocalcemia than MIBI SPECT/CT thanks to its superior sensitivity. Trial Registration: ClinicalTrials.gov Identifier: NCT04040946.

10.
Eur J Nucl Med Mol Imaging ; 40(7): 985-96, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23564036

RESUMEN

PURPOSE: We prospectively evaluated whether a strategy using point spread function (PSF) reconstruction for both diagnostic and quantitative analysis in non-small cell lung cancer (NSCLC) patients meets the European Association of Nuclear Medicine (EANM) guidelines for harmonization of quantitative values. METHODS: The NEMA NU-2 phantom was used to determine the optimal filter to apply to PSF-reconstructed images in order to obtain recovery coefficients (RCs) fulfilling the EANM guidelines for tumour positron emission tomography (PET) imaging (PSF(EANM)). PET data of 52 consecutive NSCLC patients were reconstructed with unfiltered PSF reconstruction (PSF(allpass)), PSF(EANM) and with a conventional ordered subset expectation maximization (OSEM) algorithm known to meet EANM guidelines. To mimic a situation in which a patient would undergo pre- and post-therapy PET scans on different generation PET systems, standardized uptake values (SUVs) for OSEM reconstruction were compared to SUVs for PSF(EANM) and PSF(allpass) reconstruction. RESULTS: Overall, in 195 lesions, Bland-Altman analysis demonstrated that the mean ratio between PSF(EANM) and OSEM data was 1.03 [95% confidence interval (CI) 0.94-1.12] and 1.02 (95% CI 0.90-1.14) for SUV(max) and SUV(mean), respectively. No difference was noticed when analysing lesions based on their size and location or on patient body habitus and image noise. Ten patients (84 lesions) underwent two PET scans for response monitoring. Using the European Organization for Research and Treatment of Cancer (EORTC) criteria, there was an almost perfect agreement between OSEM(PET1)/OSEM(PET2) (current standard) and OSEM(PET1)/PSF(EANM-PET2) or PSF(EANM-PET1)/OSEM(PET2) with kappa values of 0.95 (95% CI 0.91-1.00) and 0.99 (95% CI 0.96-1.00), respectively. The use of PSF(allpass) either for pre- or post-treatment (i.e. OSEM(PET1)/PSF(allpass-PET2) or PSF(allpass-PET1)/OSEM(PET2)) showed considerably less agreement with kappa values of 0.75 (95% CI 0.67-0.83) and 0.86 (95% CI 0.78-0.94), respectively. CONCLUSION: Protocol-optimized images and compliance with EANM guidelines allowed for a reliable pre- and post-therapy evaluation when using different generation PET systems. These data obtained in NSCLC patients could be extrapolated to other solid tumours.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/metabolismo , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/metabolismo , Tomografía de Emisión de Positrones/normas , Anciano , Anciano de 80 o más Años , Transporte Biológico , Carcinoma de Pulmón de Células no Pequeñas/terapia , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Neoplasias Pulmonares/terapia , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Estudios Prospectivos , Estándares de Referencia , Reproducibilidad de los Resultados , Resultado del Tratamiento
11.
Front Med (Lausanne) ; 10: 1137514, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36993807

RESUMEN

Introduction: The yield per elution of a 68Ge/68Ga generator decreases during its lifespan. This affects the number of patients injected per elution or the injected dose per patient, thereby negatively affecting the cost of examinations and the quality of PET images due to increased image noise. We aimed to investigate whether AI-based PET denoising can offset this decrease in image quality parameters. Methods: All patients addressed to our PET unit for a 68Ga-DOTATOC PET/CT from April 2020 to February 2021 were enrolled. Forty-four patients underwent their PET scans according to Protocol_FixedDose (150 MBq) and 32 according to Protocol_WeightDose (1.5 MBq/kg). Protocol_WeightDose examinations were processed using the Subtle PET software (Protocol_WeightDoseAI). Liver and vascular SUV mean were recorded as well as SUVmax, SUVmean and metabolic tumour volume (MTV) of the most intense tumoural lesion and its background SUVmean. Liver and vascular coefficients of variation (CV), tumour-to-background and tumour-to-liver ratios were calculated. Results: The mean injected dose of 2.1 (0.4) MBq/kg per patient was significantly higher in the Protocol_FixedDose group as compared to 1.5 (0.1) MBq/kg for the Protocol_WeightDose group. Protocol_WeightDose led to noisier images than Protocol_FixedDose with higher CVs for liver (15.57% ± 4.32 vs. 13.04% ± 3.51, p = 0.018) and blood-pool (28.67% ± 8.65 vs. 22.25% ± 10.37, p = 0.0003). Protocol_WeightDoseAI led to less noisy images than Protocol_WeightDose with lower liver CVs (11.42% ± 3.05 vs. 15.57% ± 4.32, p < 0.0001) and vascular CVs (16.62% ± 6.40 vs. 28.67% ± 8.65, p < 0.0001). Tumour-to-background and tumour-to-liver ratios were lower for protocol_WeightDoseAI: 6.78 ± 3.49 vs. 7.57 ± 4.73 (p = 0.01) and 5.96 ± 5.43 vs. 6.77 ± 6.19 (p < 0.0001), respectively. MTVs were higher after denoising whereas tumour SUVmax were lower: the mean% differences in MTV and SUVmax were + 11.14% (95% CI = 4.84-17.43) and -3.92% (95% CI = -6.25 to -1.59). Conclusion: The degradation of PET image quality due to a reduction in injected dose at the end of the 68Ge/68Ga generator lifespan can be effectively counterbalanced by using AI-based PET denoising.

12.
Diagnostics (Basel) ; 13(9)2023 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-37175017

RESUMEN

Given the constant pressure to increase patient throughput while respecting radiation protection, global body PET image quality (IQ) is not satisfactory in all patients. We first studied the association between IQ and other variables, in particular body habitus, on a digital PET/CT. Second, to improve and homogenize IQ, we evaluated a deep learning PET denoising solution (Subtle PETTM) using convolutional neural networks. We analysed retrospectively in 113 patients visual IQ (by a 5-point Likert score in two readers) and semi-quantitative IQ (by the coefficient of variation in the liver, CVliv) as well as lesion detection and quantification in native and denoised PET. In native PET, visual and semi-quantitative IQ were lower in patients with larger body habitus (p < 0.0001 for both) and in men vs. women (p ≤ 0.03 for CVliv). After PET denoising, visual IQ scores increased and became more homogeneous between patients (4.8 ± 0.3 in denoised vs. 3.6 ± 0.6 in native PET; p < 0.0001). CVliv were lower in denoised PET than in native PET, 6.9 ± 0.9% vs. 12.2 ± 1.6%; p < 0.0001. The slope calculated by linear regression of CVliv according to weight was significantly lower in denoised than in native PET (p = 0.0002), demonstrating more uniform CVliv. Lesion concordance rate between both PET series was 369/371 (99.5%), with two lesions exclusively detected in native PET. SUVmax and SUVpeak of up to the five most intense native PET lesions per patient were lower in denoised PET (p < 0.001), with an average relative bias of -7.7% and -2.8%, respectively. DL-based PET denoising by Subtle PETTM allowed [18F]FDG PET global image quality to be improved and homogenized, while maintaining satisfactory lesion detection and quantification. DL-based denoising may render body habitus adaptive PET protocols unnecessary, and pave the way for the improvement and homogenization of PET modalities.

13.
Clin Nucl Med ; 47(3): 275-276, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-34661560

RESUMEN

ABSTRACT: Since worldwide COVID-19 vaccination, 18F-FDG uptake in reactive axillary lymph nodes has been frequently observed in PET/CT studies. We describe a patient with breast cancer who underwent 18F-FDG PET/CT 7 days after receiving COVID-19 vaccination in the right thigh. 18F-FDG uptake was observed in nonenlarged right-sided inguinal, iliac, and para-aortic lymph nodes. As the thigh can be used as an alternate site for COVID-19 vaccine injection in case of lymphedema in both arms or for adequate axillary staging in patients with breast cancer, physicians should be aware of such 18F-FDG uptake pattern.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Fluorodesoxiglucosa F18 , Humanos , Ganglios Linfáticos/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , SARS-CoV-2 , Muslo/diagnóstico por imagen , Vacunación
14.
J Nucl Med ; 63(7): 995-1000, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34675110

RESUMEN

Despite the feminization of the medical workforce, women do not have the same career perspectives as men. In nuclear medicine, little information is available on the sex gap regarding prominent author positions in scientific articles. Therefore, the purpose of this study was to evaluate recent trends in the sex distribution of first and last authorship of articles published in nuclear medicine journals. Methods: We conducted a bibliometric analysis of first and last author sex of articles published from 2014 to 2020 in 15 nuclear medicine journals. Manuscript title, article type, journal impact factor, date of publication, and first and last name and country of provenance of first and last authors were noted. The Gender API software was used to determine author sex. All statistics were descriptive. Results: Women represented 32.8% of first authors and 19.6% of last authors. Female authorship increased from 28.2% (428 of 1,518 articles) in 2014 to 35.5% (735 of 2,069 articles; relative increase, 72%) in 2020 (P < 0.001) for first authors and from 15.6% (237 of 1,518 articles) in 2014 to 20.5% (424 of 2,069 articles; relative increase, 79%) in 2020 (P < 0.001) for last authors. Parity was forecast for 2035 for first authors and 2052 for last authors. Female authorship increased in Europe for first authors (P = 0.014) and last authors (P < 0.001), in high-ranking journals for first authors (P = 0.004) and last authors (P < 0.001), and in other journal ranks for last authors (P = 0.01). Female first and last authorship rose for original articles (P = 0.02 and P = 0.01, respectively) and case reports (P < 0.001 and P = 0.002, respectively). Regarding collaborations, the proportion of articles produced by male first and last authors decreased from 62.2% in 2014 to 52.9% in 2020 in favor of female first and last authors (odds ratio, 1.07; P < 0.001), male first and female last authors (odds ratio, 1.05; P < 0.001), and female first and male last authors (odds ratio, 1.03; P < 0.001). Conclusion: Female first and last authorship in nuclear medicine journals increased substantially from 2014 to 2020, in particular in high-ranking journals, in Europe, and for original articles and case reports. Male-to-male collaborations decreased by 10% in favor of all other collaborations. Parity can be foreseen in a few decades.


Asunto(s)
Medicina Nuclear , Publicaciones Periódicas como Asunto , Autoria , Femenino , Humanos , Factor de Impacto de la Revista , Masculino , Edición
15.
Medicine (Baltimore) ; 100(40): e27455, 2021 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-34622868

RESUMEN

RATIONALE: Peptide receptor radionuclide therapy with 177Lu-Dotatate represents a major breakthrough in the treatment of metastatic well differentiated neuroendocrine tumors. This treatment is generally well tolerated. Reported severe long-term hematological side effects are rare and include hematopoietic neoplasms and bone marrow failure. PATIENTS CONCERNS: We describe the case of a patient presenting spontaneous bleeding and bruising occurring 6 weeks after the first administration of 177Lu-Dotatate. Blood tests showed anemia, thrombocytopenia, prolonged clotting times, profound fibrinolysis and low levels of coagulation factors II and V. There were no signs of tumor lysis syndrome. DIAGNOSES: We made the diagnosis of acute disseminated intravascular coagulation. INTERVENTION: Treatment consisted of multiple transfusions of fresh frozen plasma, fibrinogen and platelets, and corticosteroids. Acute disseminated intravascular coagulation (DIC) persisted for 10 days and then resolved. OUTCOMES: Metabolic imaging 5 months after the 177Lu-Dotatate administration showed disease progression. Treatment with 177Lu-Dotatate was not rechallenged due to the occurrence of DIC. LESSONS: Our case suggests that acute hemorrhagic disseminated intravascular coagulation can be a rare and life-threatening subacute side effect of 177Lu-Dotatate peptide receptor radionuclide therapy.


Asunto(s)
Coagulación Intravascular Diseminada/inducido químicamente , Octreótido/análogos & derivados , Compuestos Organometálicos/efectos adversos , Femenino , Hemorragia/inducido químicamente , Humanos , Neoplasias del Íleon/tratamiento farmacológico , Persona de Mediana Edad , Tumores Neuroendocrinos/tratamiento farmacológico , Octreótido/efectos adversos , Octreótido/uso terapéutico , Compuestos Organometálicos/uso terapéutico
18.
EJNMMI Phys ; 4(1): 17, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28560574

RESUMEN

BACKGROUND: This study evaluates the consistency of PET evaluation response criteria in solid tumours (PERCIST) and European Organisation for Research and Treatment of Cancer (EORTC) classification across different reconstruction algorithms and whether aligning standardized uptake values (SUVs) to the European Association of Nuclear Medicine acquisition (EANM)/EARL standards provides more consistent response classification. MATERIALS AND METHODS: Baseline (PET1) and response assessment (PET2) scans in 61 patients with non-small cell lung cancer were acquired in protocols compliant with the EANM guidelines and were reconstructed with point-spread function (PSF) or PSF + time-of-flight (TOF) reconstruction for optimal tumour detection and with a standardized ordered subset expectation maximization (OSEM) reconstruction known to fulfil EANM harmonizing standards. Patients were recruited in three centres. Following reconstruction, EQ.PET, a proprietary software solution was applied to the PSF ± TOF data (PSF ± TOF.EQ) to harmonize SUVs to the EANM standards. The impact of differing reconstructions on PERCIST and EORTC classification was evaluated using standardized uptake values corrected for lean body mass (SUL). RESULTS: Using OSEMPET1/OSEMPET2 (standard scenario), responders displayed a reduction of -57.5% ± 23.4 and -63.9% ± 22.4 for SULmax and SULpeak, respectively, while progressing tumours had an increase of +63.4% ± 26.5 and +60.7% ± 19.6 for SULmax and SULpeak respectively. The use of PSF ± TOF reconstruction impacted the classification of tumour response. For example, taking the OSEMPET1/PSF ± TOFPET2 scenario reduced the apparent reduction in SUL in responding tumours (-39.7% ± 31.3 and -55.5% ± 26.3 for SULmax and SULpeak, respectively) but increased the apparent increase in SUL in progressing tumours (+130.0% ± 50.7 and +91.1% ± 39.6 for SULmax and SULpeak, respectively). Consequently, variation in reconstruction methodology (PSF ± TOFPET1/OSEMPET2 or OSEM PET1/PSF ± TOFPET2) led, respectively, to 11/61 (18.0%) and 10/61 (16.4%) PERCIST classification discordances and to 17/61 (28.9%) and 19/61 (31.1%) EORTC classification discordances. An agreement was better for these scenarios with application of the propriety filter, with kappa values of 1.00 and 0.95 compared to 0.75 and 0.77 for PERCIST and kappa values of 0.93 and 0.95 compared to 0.61 and 0.55 for EORTC, respectively. CONCLUSION: PERCIST classification is less sensitive to reconstruction algorithm-dependent variability than EORTC classification but harmonizing SULs within the EARL program is equally effective with either.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA