Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 196
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur J Nucl Med Mol Imaging ; 51(5): 1451-1461, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38133687

RESUMEN

PURPOSE: To evaluate if a machine learning prediction model based on clinical and easily assessable imaging features derived from baseline breast [18F]FDG-PET/MRI staging can predict pathologic complete response (pCR) in patients with newly diagnosed breast cancer prior to neoadjuvant system therapy (NAST). METHODS: Altogether 143 women with newly diagnosed breast cancer (54 ± 12 years) were retrospectively enrolled. All women underwent a breast [18F]FDG-PET/MRI, a histopathological workup of their breast cancer lesions and evaluation of clinical data. Fifty-six features derived from positron emission tomography (PET), magnetic resonance imaging (MRI), sociodemographic / anthropometric, histopathologic as well as clinical data were generated and used as input for an extreme Gradient Boosting model (XGBoost) to predict pCR. The model was evaluated in a five-fold nested-cross-validation incorporating independent hyper-parameter tuning within the inner loops to reduce the risk of overoptimistic estimations. Diagnostic model-performance was assessed by determining the area under the curve of the receiver operating characteristics curve (ROC-AUC), sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy. Furthermore, feature importances of the XGBoost model were evaluated to assess which features contributed most to distinguish between pCR and non-pCR. RESULTS: Nested-cross-validation yielded a mean ROC-AUC of 80.4 ± 6.0% for prediction of pCR. Mean sensitivity, specificity, PPV, and NPV of 54.5 ± 21.3%, 83.6 ± 4.2%, 63.6 ± 8.5%, and 77.6 ± 8.1% could be achieved. Histopathological data were the most important features for classification of the XGBoost model followed by PET, MRI, and sociodemographic/anthropometric features. CONCLUSION: The evaluated multi-source XGBoost model shows promising results for reliably predicting pathological complete response in breast cancer patients prior to NAST. However, yielded performance is yet insufficient to be implemented in the clinical decision-making process.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/terapia , Fluorodesoxiglucosa F18 , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones , Aprendizaje Automático
2.
BMC Med Imaging ; 24(1): 4, 2024 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-38166655

RESUMEN

BACKGROUND: Susac syndrome (SuS) is a rare autoimmune disease that leads to hearing impairment, visual field deficits, and encephalopathy due to an occlusion of precapillary arterioles in the brain, retina, and inner ear. Given the potentially disastrous outcome and difficulties in distinguishing SuS from its differential diagnoses, such as multiple sclerosis (MS), our exploratory study aimed at identifying potential new SuS-specific neuroimaging markers. METHODS: Seven patients with a definite diagnosis of SuS underwent magnetic resonance imaging (MRI) at 7 Tesla (7T), including T2* weighted and quantitative susceptibility mapping (QSM) sequences. T2 weighted hyperintense lesions were analyzed with regard to number, volume, localization, central vein sign, T1 hypointensity, and focal iron deposits in the center of SuS lesions ("iron dots"). Seven T MRI datasets from the same institute, comprising 75 patients with, among others, MS, served as controls. RESULTS: The "iron dot" sign was present in 71.4% (5/7) of the SuS patients, compared to 0% in our control cohort. Thus, sensitivity was 71.4% and specificity 100%. A central vein sign was only incidentally detected. CONCLUSION: We are the first to demonstrate this type of "iron dot" lesions on highly resolving 7T T2*w and QSM images in vivo as a promising neuroimaging marker of SuS, corroborating previous histopathological ex vivo findings.


Asunto(s)
Esclerosis Múltiple , Síndrome de Susac , Humanos , Síndrome de Susac/diagnóstico por imagen , Síndrome de Susac/patología , Hierro , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Imagen por Resonancia Magnética/métodos , Esclerosis Múltiple/diagnóstico por imagen
3.
Eur J Nucl Med Mol Imaging ; 50(12): 3513-3537, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37624384

RESUMEN

PREAMBLE: The Society of Nuclear Medicine and Molecular Imaging (SNMMI) is an international scientific and professional organization founded in 1954 to promote the science, technology, and practical application of nuclear medicine. The European Association of Nuclear Medicine (EANM) is a professional non-profit medical association that facilitates communication worldwide between individuals pursuing clinical and research excellence in nuclear medicine. The EANM was founded in 1985. The merged International Society for Magnetic Resonance in Medicine (ISMRM) is an international, nonprofit, scientific association whose purpose is to promote communication, research, development, and applications in the field of magnetic resonance in medicine and biology and other related topics and to develop and provide channels and facilities for continuing education in the field.The ISMRM was founded in 1994 through the merger of the Society of Magnetic Resonance in Medicine and the Society of Magnetic Resonance Imaging. SNMMI, ISMRM, and EANM members are physicians, technologists, and scientists specializing in the research and practice of nuclear medicine and/or magnetic resonance imaging. The SNMMI, ISMRM, and EANM will periodically define new guidelines for nuclear medicine practice to help advance the science of nuclear medicine and/or magnetic resonance imaging and to improve the quality of service to patients throughout the world. Existing practice guidelines will be reviewed for revision or renewal, as appropriate, on their fifth anniversary or sooner, if indicated. Each practice guideline, representing a policy statement by the SNMMI/EANM/ISMRM, has undergone a thorough consensus process in which it has been subjected to extensive review. The SNMMI, ISMRM, and EANM recognize that the safe and effective use of diagnostic nuclear medicine imaging and magnetic resonance imaging requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guideline by those entities not providing these services is not authorized. These guidelines are an educational tool designed to assist practitioners in providing appropriate care for patients. They are not inflexible rules or requirements of practice and are not intended, nor should they be used, to establish a legal standard of care. For these reasons and those set forth below, the SNMMI, the ISMRM, and the EANM caution against the use of these guidelines in litigation in which the clinical decisions of a practitioner are called into question. The ultimate judgment regarding the propriety of any specific procedure or course of action must be made by the physician or medical physicist in light of all the circumstances presented. Thus, there is no implication that an approach differing from the guidelines, standing alone, is below the standard of care. To the contrary, a conscientious practitioner may responsibly adopt a course of action different from that set forth in the guidelines when, in the reasonable judgment of the practitioner, such course of action is indicated by the condition of the patient, limitations of available resources, or advances in knowledge or technology subsequent to publication of the guidelines. The practice of medicine includes both the art and the science of the prevention, diagnosis, alleviation, and treatment of disease. The variety and complexity of human conditions make it impossible to always reach the most appropriate diagnosis or to predict with certainty a particular response to treatment. Therefore, it should be recognized that adherence to these guidelines will not ensure an accurate diagnosis or a successful outcome. All that should be expected is that the practitioner will follow a reasonable course of action based on current knowledge, available resources, and the needs of the patient to deliver effective and safe medical care. The sole purpose of these guidelines is to assist practitioners in achieving this objective.

4.
Eur Radiol ; 33(11): 8366-8375, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37338559

RESUMEN

OBJECTIVES: Evaluate the influence of an MRI contrast agent application on primary and follow-up staging in pediatric patients with newly diagnosed lymphoma using [18F]FDG PET/MRI to avoid adverse effects and save time and costs during examination. METHODS: A total of 105 [18F]FDG PET/MRI datasets were included for data evaluation. Two different reading protocols were analyzed by two experienced readers in consensus, including for PET/MRI-1 reading protocol unenhanced T2w and/or T1w imaging, diffusion-weighted imaging (DWI), and [18F]FDG PET imaging and for PET/MRI-2 reading protocol an additional T1w post contrast imaging. Patient-based and region-based evaluation according to the revised International Pediatric Non-Hodgkin's Lymphoma (NHL) Staging System (IPNHLSS) was performed, and a modified standard of reference was applied comprising histopathology and previous and follow-up cross-sectional imaging. Differences in staging accuracy were assessed using the Wilcoxon and McNemar tests. RESULTS: In patient-based analysis, PET/MRI-1 and PET/MRI-2 both determined a correct IPNHLSS tumor stage in 90/105 (86%) exams. Region-based analysis correctly identified 119/127 (94%) lymphoma-affected regions. Sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy for PET/MRI-1 and PET/MRI-2 were 94%, 97%, 90%, 99%, 97%, respectively. There were no significant differences between PET/MRI-1 and PET/MRI-2. CONCLUSIONS: The use of MRI contrast agents in [18F]FDG PET/MRI examinations has no beneficial effect in primary and follow-up staging of pediatric lymphoma patients. Therefore, switching to a contrast agent-free [18F]FDG PET/MRI protocol should be considered in all pediatric lymphoma patients. CLINICAL RELEVANCE STATEMENT: This study gives a scientific baseline switching to a contrast agent-free [18F]FDG PET/MRI staging in pediatric lymphoma patients. This could avoid side effects of contrast agents and saves time and costs by a faster staging protocol for pediatric patients. KEY POINTS: • No additional diagnostic benefit of MRI contrast agents at [18F]FDG PET/MRI examinations of pediatric lymphoma primary and follow-up staging • Highly accurate primary and follow-up staging of pediatric lymphoma patients at MRI contrast-free [18F]FDG PET/MRI.


Asunto(s)
Fluorodesoxiglucosa F18 , Linfoma , Humanos , Niño , Fluorodesoxiglucosa F18/farmacología , Medios de Contraste/farmacología , Estadificación de Neoplasias , Imagen por Resonancia Magnética/métodos , Linfoma/diagnóstico por imagen , Linfoma/patología , Tomografía de Emisión de Positrones/métodos , Radiofármacos/farmacología , Sensibilidad y Especificidad
5.
Eur Radiol ; 33(9): 6179-6188, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37045980

RESUMEN

OBJECTIVES: To investigate the diagnostic feasibility of a shortened breast PET/MRI protocol in breast cancer patients. METHODS: Altogether 90 women with newly diagnosed T1tumor-staged (T1ts) and T2tumor-staged (T2ts) breast cancer were included in this retrospective study. All underwent a dedicated comprehensive breast [18F]FDG-PET/MRI. List-mode PET data were retrospectively reconstructed with 20, 15, 10, and 5 min for each patient to simulate the effect of reduced PET acquisition times. The SUVmax/mean of all malign breast lesions was measured. Furthermore, breast PET data reconstructions were analyzed regarding image quality, lesion detectability, signal-to-noise ratio (SNR), and image noise (IN). The simultaneously acquired comprehensive MRI protocol was then shortened by retrospectively removing sequences from the protocol. Differences in malignant breast lesion detectability between the original and the fast breast MRI protocol were evaluated lesion-based. The 20-min PET reconstructions and the original MRI protocol served as reference. RESULTS: In all PET reconstructions, 127 congruent breast lesions could be detected. Group comparison and T1ts vs. T2ts subgroup comparison revealed no significant difference of subjective image quality between 20, 15, 10, and 5 min acquisition times. SNR of qualitative image evaluation revealed no significant difference between different PET acquisition times. A slight but significant increase of IN with decreasing PET acquisition times could be detected. Lesion SUVmax group comparison between all PET acquisition times revealed no significant differences. Lesion-based evaluation revealed no significant difference in breast lesion detectability between original and fast breast MRI protocols. CONCLUSIONS: Breast [18F]FDG-PET/MRI protocols can be shortened from 20 to below 10 min without losing essential diagnostic information. KEY POINTS: • A highly accurate breast cancer evaluation is possible by the shortened breast [18F]FDG-PET/MRI examination protocol. • Significant time saving at breast [18F]FDG-PET/MRI protocol could increase patient satisfaction and patient throughput for breast cancer patients at PET/MRI.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Estudios Retrospectivos , Radiofármacos/farmacología , Tomografía de Emisión de Positrones/métodos , Imagen por Resonancia Magnética/métodos
6.
Eur Radiol ; 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38038758

RESUMEN

OBJECTIVES: To investigate the specific strengths of MRI and PET components in 68Ga-PSMA-11 PET/MRI for staging of patients with biochemically recurrent prostate cancer (PCa). METHODS: Patients with biochemical recurrence of PCa and contrast-enhanced whole-body 68Ga-PSMA-11 PET/MRI including a dedicated pelvic multiparametric MRI were included in this retrospective study. Imaging datasets of MRI and PET were evaluated separately regarding local PCa recurrence (Tr), pelvic lymph node metastases (N1), distant lymph node metastases (M1a), bone metastases (M1b), and soft tissue metastases (M1c) according to PROMISE version 1. Data evaluation was performed patient- and region-/lesion-based. Cox regression revealed a PSA of 1.69 ng/mL as a cut-off for subgroup analysis. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were evaluated for each image component. Differences in staging accuracy were assessed using the Wilcoxon and McNemar test. RESULTS: Altogether 102 patients (mean aged 68 ± 8 years, median PSA 1.33 ng/mL) were included. PCa was found in 70/102 (68%) patients. Accuracy of MRI in the detection of Tr, N1, M + , M1a, and M1b was 100%, 79%, 90%, 97%, and 95% for PSA < 1.69 ng/mL and 100%, 87%, 87%, 91%, and 96% for PSA > 1.69 ng/mL. Accuracy of 68Ga-PSMA-11 PET was 93%, 97%, 93%, 98%, and 100% for PSA < 1.69 ng/mL and 87%, 91%, 96%, 100%, and 96% for PSA > 1.69 ng/mL. CONCLUSIONS: Combined assessment of 68Ga-PSMA-11 PET/MRI improves tumor localization in men with biochemical recurrence. The MRI detected local recurrence of PCa more often whereas 68 Ga-PSMA-11 PET detected lymph node metastases more often, especially for PSA < 1.69 ng/mL. CLINICAL RELEVANCE STATEMENT: This study gives a scientific baseline to improve the understanding and reading of 68Ga-PSMA-11 PET/MRI imaging in patients with biochemically recurrent PCa by showing the specific strength of each imaging component. KEY POINTS: • Combining the individual modality strengths of 68Ga-PSMA-11 PET/MRI improves tumor localization in men with biochemical recurrence of prostate cancer. • MRI component of 68 Ga-PSMA-11 PET/MRI shows its strength in detecting local recurrence of prostate cancer, especially at PSA < 1.69 ng/mL. • 68 Ga-PSMA-11 PET component shows its strength in detecting local and distant lymph node metastases, especially at PSA < 1.69 ng/mL.

7.
MAGMA ; 36(5): 725-735, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36933090

RESUMEN

OBJECTIVE: This study presents an extended evaluation of a numerical approach to simulate artifacts of metallic implants in an MR environment. METHODS: The numerical approach is validated by comparing the artifact shape of the simulations and measurements of two metallic orthopedic implants at three different field strengths (1.5 T, 3 T, and 7 T). Furthermore, this study presents three additional use cases of the numerical simulation. The first one shows how numerical simulations can improve the artifact size evaluation according to ASTM F2119. The second use case quantifies the influence of different imaging parameters (TE and bandwidth) on the artifact size. Finally, the third use case shows the potential of performing human model artifact simulations. RESULTS: The numerical simulation approach shows a dice similarity coefficient of 0.74 between simulated and measured artifact sizes of metallic implants. The alternative artifact size calculation method presented in this study shows that the artifact size of the ASTM-based method is up to 50% smaller for complex shaped implants compared to the numerical-based approach. CONCLUSION: In conclusion, the numerical approach could be used in the future to extend MR safety testing according to a revision of the ASTM F2119 standard and for design optimization during the development process of implants.


Asunto(s)
Artefactos , Prótesis e Implantes , Humanos , Simulación por Computador , Imagen por Resonancia Magnética/métodos
8.
MAGMA ; 36(2): 191-210, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37029886

RESUMEN

Multiple sites within Germany operate human MRI systems with magnetic fields either at 7 Tesla or 9.4 Tesla. In 2013, these sites formed a network to facilitate and harmonize the research being conducted at the different sites and make this technology available to a larger community of researchers and clinicians not only within Germany, but also worldwide. The German Ultrahigh Field Imaging (GUFI) network has defined a strategic goal to establish a 14 Tesla whole-body human MRI system as a national research resource in Germany as the next progression in magnetic field strength. This paper summarizes the history of this initiative, the current status, the motivation for pursuing MR imaging and spectroscopy at such a high magnetic field strength, and the technical and funding challenges involved. It focuses on the scientific and science policy process from the perspective in Germany, and is not intended to be a comprehensive systematic review of the benefits and technical challenges of higher field strengths.


Asunto(s)
Imagen por Resonancia Magnética , Imagen de Cuerpo Entero , Humanos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Imagen de Cuerpo Entero/métodos , Alemania , Campos Magnéticos
9.
Neuroimage ; 253: 119080, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35276369

RESUMEN

The cerebellum is involved in the acquisition and consolidation of learned fear responses. Knowledge about its contribution to extinction learning, however, is sparse. Extinction processes likely involve erasure of memories, but there is ample evidence that at least part of the original memory remains. We asked the question whether memory persists within the cerebellum following extinction training. The renewal effect, that is the reoccurrence of the extinguished fear memory during recall in a context different from the extinction context, constitutes one of the phenomena indicating that memory of extinguished learned fear responses is not fully erased during extinction training. We performed a differential AB-A/B fear conditioning paradigm in a 7-Tesla (7T) MRI system in 31 young and healthy men. On day 1, fear acquisition training was performed in context A and extinction training in context B. On day 2, recall was tested in contexts A and B. As expected, participants learned to predict that the CS+ was followed by an aversive electric shock during fear acquisition training. Skin conductance responses (SCRs) were significantly higher to the CS+ compared to the CS- at the end of acquisition. Differences in SCRs vanished in extinction and reoccurred in the acquisition context during recall indicating renewal. Fitting SCR data, a deep neural network model was trained to predict the correct shock value for a given stimulus and context. Event-related fMRI analysis with model-derived prediction values as parametric modulations showed significant effects on activation of the posterolateral cerebellum (lobules VI and Crus I) during recall. Since the prediction values differ based on stimulus (CS+ and CS-) and context during recall, data provide support that the cerebellum is involved in context-related recall of learned fear associations. Likewise, mean ß values were highest in lobules VI and Crus I bilaterally related to the CS+ in the acquisition context during early recall. A similar pattern was seen in the vermis, but only on a trend level. Thus, part of the original memory likely remains within the cerebellum following extinction training. We found cerebellar activations related to the CS+ and CS- during fear acquisition training which likely reflect associative and non-associative aspects of the task. Cerebellar activations, however, were not significantly different for CS+ and CS-. Since the CS- was never followed by an electric shock, the cerebellum may contribute to associative learning related to the CS, for example as a safety cue.


Asunto(s)
Extinción Psicológica , Miedo , Mapeo Encefálico , Cerebelo/diagnóstico por imagen , Cerebelo/fisiología , Extinción Psicológica/fisiología , Miedo/fisiología , Respuesta Galvánica de la Piel , Humanos , Imagen por Resonancia Magnética , Masculino
10.
NMR Biomed ; 35(5): e4656, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34962689

RESUMEN

In this study, the performance of an integrated body-imaging array for 7 T with 32 radiofrequency (RF) channels under consideration of local specific absorption rate (SAR), tissue temperature, and thermal dose limits was evaluated and the imaging performance was compared with a clinical 3 T body coil. Thirty-two transmit elements were placed in three rings between the bore liner and RF shield of the gradient coil. Slice-selective RF pulse optimizations for B1 shimming and spokes were performed for differently oriented slices in the body under consideration of realistic constraints for power and local SAR. To improve the B1+ homogeneity, safety assessments based on temperature and thermal dose were performed to possibly allow for higher input power for the pulse optimization than permissible with SAR limits. The results showed that using two spokes, the 7 T array outperformed the 3 T birdcage in all the considered regions of interest. However, a significantly higher SAR or lower duty cycle at 7 T is necessary in some cases to achieve similar B1+ homogeneity as at 3 T. The homogeneity in up to 50 cm-long coronal slices can particularly benefit from the high RF shim performance provided by the 32 RF channels. The thermal dose approach increases the allowable input power and the corresponding local SAR, in one example up to 100 W/kg, without limiting the exposure time necessary for an MR examination. In conclusion, the integrated antenna array at 7 T enables a clinical workflow for body imaging and comparable imaging performance to a conventional 3 T clinical body coil.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Temperatura
11.
MAGMA ; 35(3): 485-497, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34655346

RESUMEN

OBJECTIVE: This study presents the development and evaluation of a numerical approach to simulate artifacts of metallic implants in an MR environment that can be applied to improve the testing procedure for MR image artifacts in medical implants according to ASTM F2119. METHODS: The numerical approach is validated by comparing simulations and measurements of two metallic test objects made of titanium and stainless steel at three different field strengths (1.5T, 3T and 7T). The difference in artifact size and shape between the simulated and measured artifacts were evaluated. A trend analysis of the artifact sizes in relation to the field strength was performed. RESULTS: The numerical simulation approach shows high similarity (between 75% and 84%) of simulated and measured artifact sizes of metallic implants. Simulated and measured artifact sizes in relation to the field strength resulted in a calculation guideline to determine and predict the artifact size at one field strength (e.g., 3T or 7T) based on a measurement that was obtained at another field strength only (e.g. 1.5T). CONCLUSION: This work presents a novel tool to improve the MR image artifact testing procedure of passive medical implants. With the help of this tool detailed artifact investigations can be performed, which would otherwise only be possible with substantial measurement effort on different MRI systems and field strengths.


Asunto(s)
Artefactos , Prótesis e Implantes , Imagen por Resonancia Magnética/métodos , Titanio
12.
Neuroimage ; 232: 117910, 2021 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-33647497

RESUMEN

OBJECT: This study evaluates inter-site and intra-site reproducibility at ten different 7 T sites for quantitative brain imaging. MATERIAL AND METHODS: Two subjects - termed the "traveling heads" - were imaged at ten different 7 T sites with a harmonized quantitative brain MR imaging protocol. In conjunction with the system calibration, MP2RAGE, QSM, CEST and multi-parametric mapping/relaxometry were examined. RESULTS: Quantitative measurements with MP2RAGE showed very high reproducibility across sites and subjects, and errors were in concordance with previous results and other field strengths. QSM had high inter-site reproducibility for relevant subcortical volumes. CEST imaging revealed systematic differences between the sites, but reproducibility was comparable to results in the literature. Relaxometry had also very high agreement between sites, but due to the high sensitivity, differences caused by different applications of the B1 calibration of the two RF coil types used were observed. CONCLUSION: Our results show that quantitative brain imaging can be performed with high reproducibility at 7 T and with similar reliability as found at 3 T for multicenter studies of the supratentorial brain.


Asunto(s)
Encéfalo/diagnóstico por imagen , Cabeza/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/normas , Imagen por Resonancia Magnética/normas , Adulto , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Masculino , Reproducibilidad de los Resultados
13.
Magn Reson Med ; 86(5): 2853-2861, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34216047

RESUMEN

PURPOSE: Compression of local specific absorption rate (SAR) matrices is essential for enabling SAR monitoring and efficient pulse calculation in parallel transmission. Improvements in compression result in lower error margin and/or lower number of virtual observation points (VOPs). The purpose of this work is to introduce two algorithms for post-processing of already compressed VOP sets. One calculates individual overestimation matrices for the VOPs to reduce overestimation, the other identifies redundant VOPs. METHODS: The first algorithm was evaluated for VOP sets calculated for three different transmit arrays with either 8 or 16 channels. For each array, two different overestimation matrices were used to generate the VOP sets. Each post-processed VOP set was evaluated using one million random excitation vectors and the results compared to the VOP set before post-processing. The second algorithm was evaluated by utilizing the same random excitation vectors and comparing the results after removal of the redundant VOPs with the results before removal to verify that these were identical. RESULTS: The first algorithm reduced the mean overestimation by up to four fifths compared to the original set, while keeping the number of VOPs constant. The second algorithm decreased the number of VOPs generated by a compression with Eichfelder and Gebhardt's algorithm by more than 40% in 40% of the investigated cases and by more than 20% in 73% of the investigated cases. CONCLUSION: Two post-processing algorithms are presented that enhance previously compressed VOP sets by improving the accuracy per number of VOPs.


Asunto(s)
Compresión de Datos , Imagen por Resonancia Magnética , Algoritmos , Fantasmas de Imagen
14.
Magn Reson Med ; 86(1): 561-568, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33634530

RESUMEN

PURPOSE: Local specific absorption rate (SAR) compression algorithms are essential for enabling online SAR monitoring in parallel transmission. A better compression resulting in a lower number of virtual observation points improves speed of SAR calculation for online supervision and pulse design. METHOD: An iterative expansion of an existing algorithm presented by Lee et al is proposed in this work. The original algorithm is used within a loop, making use of the virtual observation points from the previous iteration as the starting subvolume, while decreasing the overestimation with each iteration. This algorithm is evaluated on the SAR matrices of three different simulated arrays. RESULT: The number of virtual observation points is approximately halved with the new algorithm, while at the same time the compression time is reduced with speed-up factors of up to 2.5. CONCLUSION: The new algorithm improves the original algorithm in terms of compression rate and speed.


Asunto(s)
Compresión de Datos , Imagen por Resonancia Magnética , Algoritmos
15.
NMR Biomed ; 34(7): e4515, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33942938

RESUMEN

The aim of the current study was to investigate the performance of integrated RF transmit arrays with high channel count consisting of meander microstrip antennas for body imaging at 7 T and to optimize the position and number of transmit elements. RF simulations using multiring antenna arrays placed behind the bore liner were performed for realistic exposure conditions for body imaging. Simulations were performed for arrays with as few as eight elements and for arrays with high channel counts of up to 48 elements. The B1+ field was evaluated regarding the degrees of freedom for RF shimming in the abdomen. Worst-case specific absorption rate (SARwc ), SAR overestimation in the matrix compression, the number of virtual observation points (VOPs) and SAR efficiency were evaluated. Constrained RF shimming was performed in differently oriented regions of interest in the body, and the deviation from a target B1+ field was evaluated. Results show that integrated multiring arrays are able to generate homogeneous B1+ field distributions for large FOVs, especially for coronal/sagittal slices, and thus enable body imaging at 7 T with a clinical workflow; however, a low duty cycle or a high SAR is required to achieve homogeneous B1+ distributions and to exploit the full potential. In conclusion, integrated arrays allow for high element counts that have high degrees of freedom for the pulse optimization but also produce high SARwc , which reduces the SAR accuracy in the VOP compression for low-SAR protocols, leading to a potential reduction in array performance. Smaller SAR overestimations can increase SAR accuracy, but lead to a high number of VOPs, which increases the computational cost for VOP evaluation and makes online SAR monitoring or pulse optimization challenging. Arrays with interleaved rings showed the best results in the study.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Ondas de Radio , Simulación por Computador , Humanos , Masculino , Modelos Biológicos
16.
MAGMA ; 34(1): 153-163, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32964299

RESUMEN

OBJECTIVE: In local SAR compression algorithms, the overestimation is generally not linearly dependent on actual local SAR. This can lead to large relative overestimation at low actual SAR values, unnecessarily constraining transmit array performance. METHOD: Two strategies are proposed to reduce maximum relative overestimation for a given number of VOPs. The first strategy uses an overestimation matrix that roughly approximates actual local SAR; the second strategy uses a small set of pre-calculated VOPs as the overestimation term for the compression. RESULT: Comparison with a previous method shows that for a given maximum relative overestimation the number of VOPs can be reduced by around 20% at the cost of a higher absolute overestimation at high actual local SAR values. CONCLUSION: The proposed strategies outperform a previously published strategy and can improve the SAR compression where maximum relative overestimation constrains the performance of parallel transmission.


Asunto(s)
Compresión de Datos , Algoritmos , Simulación por Computador , Imagen por Resonancia Magnética , Fantasmas de Imagen
17.
Stroke ; 51(8): 2505-2513, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32646326

RESUMEN

BACKGROUND AND PURPOSE: The pathophysiology of development, growth, and rupture of intracranial aneurysms (IAs) is only partly understood. Cyclooxygenase 2 (COX-2) converts arachidonic acid to prostaglandin H2, which, in turn, is isomerized to prostaglandin E2. In the human body, COX-2 plays an essential role in inflammatory pathways. This explorative study aimed to investigate COX-2 expression in the wall of IAs and its correlation to image features in clinical (1.0T, 1.5T, and 3.0T) magnetic resonance imaging (MRI) and ultra-high-field 7T MRI. METHODS: The study group comprised 40 patients with partly thrombosed saccular IAs. The cohort included 17 ruptured- and 24 unruptured IAs, which had all been treated microsurgically. Formaldehyde-fixed paraffin-embedded samples were immunohistochemically stained with a monoclonal antibody against COX-2 (Dako, Santa Clara, CA; Clone: CX-294). We correlated Perls Prussian blue staining, MRI, and clinical data with immunohistochemistry, analyzed using the Trainable Weka Segmentation algorithm. RESULTS: Aneurysm dome size ranged between 2 and 67 mm. The proportion of COX-2 positive cells ranged between 3.54% to 85.09%. An upregulated COX-2 expression correlated with increasing IA dome size (P=0.047). Furthermore, there was a tendency of higher COX-2 expression in most ruptured IAs (P=0.064). At all field strengths, MRI shows wall hypointensities due to iron deposition correlating with COX-2 expression (P=0.022). CONCLUSIONS: Iron deposition and COX-2 expression in IAs walls correlate with signal hypointensity in MRI, which might, therefore, serve as a biomarker for IA instability. Furthermore, as COX-2 was also expressed in small unruptured IAs, it could be a potential target for specific medical treatment.


Asunto(s)
Ciclooxigenasa 2/biosíntesis , Endotelio Vascular/diagnóstico por imagen , Endotelio Vascular/metabolismo , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/metabolismo , Hierro/metabolismo , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Estudios de Cohortes , Ciclooxigenasa 2/genética , Femenino , Regulación Enzimológica de la Expresión Génica , Humanos , Aneurisma Intracraneal/genética , Masculino , Persona de Mediana Edad
18.
Eur J Nucl Med Mol Imaging ; 47(10): 2269-2279, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32125487

RESUMEN

PURPOSE: This study evaluates the quantitative effect of improved MR-based attenuation correction (AC), including bone segmentation and the HUGE method for truncation correction in PET/MR whole-body hybrid imaging specifically of oncologic patients with bone metastasis and using various radiotracers. METHODS: Twenty-three patients that underwent altogether 28 whole-body PET/MR examinations with findings of bone metastasis were included in this study. Different radiotracers (18F-FDG, 68Ga-PSMA, 68Ga-DOTATOC, 124I-MIBG) were injected according to appropriate clinical indications. Each of the 28 whole-body PET datasets was reconstructed three times using AC with (1) standard four-compartment µ-maps (background air, lung, muscle, and soft tissue), (2) five-compartment µ-maps (adding bone), and (3) six-compartment µ-maps (adding bone and HUGE truncation correction). The SUVmax of each detected bone lesion was measured in each reconstruction to evaluate the quantitative impact of improved MR-based AC. Relative difference images between four- and six-compartment µ-maps were calculated. MR-based HUGE truncation correction was compared with the PET-based MLAA truncation correction method in all patients. RESULTS: Overall, 69 bone lesions were detected and evaluated. The mean increase in relative difference over all 69 lesions in SUVmax was 5.4 ± 6.4% when comparing the improved six-compartment AC with the standard four-compartment AC. Maximal relative difference of 28.4% was measured in one lesion. Truncation correction with HUGE worked robust and resulted in realistic body contouring in all 28 exams and for all 4 different radiotracers. Truncation correction with MLAA revealed overestimations of arm tissue volume in all PET/MR exams with 18F-FDG radiotracer and failed in all other exams with radiotracers 68Ga-PSMA, 68Ga-DOTATOC, and 124I- MIBG due to limitations in body contour detection. CONCLUSION: Improved MR-based AC, including bone segmentation and HUGE truncation correction in whole-body PET/MR on patients with bone lesions and using various radiotracers, is important to ensure best possible diagnostic image quality and accurate PET quantification. The HUGE method for truncation correction based on MR worked robust and results in realistic body contouring, independent of the radiotracers used.


Asunto(s)
Imagen Multimodal , Tomografía de Emisión de Positrones , Fluorodesoxiglucosa F18 , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética
19.
Magn Reson Med ; 82(5): 1859-1875, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31199013

RESUMEN

PURPOSE: To evaluate radiofrequency (RF) induced tissue heating around aneurysm clips during a 7T head MR examination and to determine the decoupling distance between multiple implanted clips. METHODS: A total of 120 RF exposure scenarios of clinical relevance were studied using specific absorption rate and temperature simulations. Variations between scenarios included 2 clips (18.8 and 51.5 mm length), 2 MR-operating modes, 2 head models, and 3 thermoregulation models. Furthermore, a conservative approach was developed to allow for safe scans of patients with aneurysm clips even if detailed information on the implanted clip is unknown. A dedicated simulation-based approach was applied to determine the decoupling distance between multiple implanted clips. RESULTS: For all 60 clinical scenarios with the 18.8-mm-long clip, the absolute tissue temperature remained below regulatory limits. For 15 of 60 scenarios with the 51.5-mm-long clip, limits were slightly exceeded (less than 1°C). The conservative approach led to a maximum time-averaged input power of the RF coil of 3.3W. The corresponding B1+ is 1.32 µT. A decoupling distance of 35 mm allows the aneurysm clips to be treated as uncoupled from one other. CONCLUSION: Safe scanning conditions with respect to RF-induced heating can be applied for single or decoupled aneurysm clips in a 7T ultra-high field MRI setting. Multiple aneurysm clips separated by less than 35 mm need further investigations.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Instrumentos Quirúrgicos/efectos adversos , Seguridad de Equipos , Calor , Humanos , Aneurisma Intracraneal/cirugía , Fantasmas de Imagen , Diseño de Prótesis , Ondas de Radio
20.
Magn Reson Med ; 82(2): 796-810, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30924181

RESUMEN

PURPOSE: A 16-channel receive (16Rx) radiofrequency (RF) array for 7T ultra-high field body MR imaging is presented. The coil is evaluated in conjunction with a 16-channel transmit/receive (16TxRx) coil and additionally with a 32-channel transmit/receive (32TxRx) remote body coil for RF transmit and serving as receive references. METHODS: The 16Rx array consists of 16 octagonal overlapping loops connected to custom-built detuning boards with preamplifiers. Performance metrics like noise correlation, g-factors, and signal-to-noise ratio gain were compared between 4 different RF coil configurations. In vivo body imaging was performed in volunteers using radiofrequency shimming, time interleaved acquisition of modes (TIAMO), and 2D spatially selective excitation using parallel transmit (pTx) in the spine. RESULTS: Lower g-factors were obtained when using the 16Rx coil in addition to the 16TxRx array coil configuration versus the 16TxRx array alone. Distinct signal-to-noise ratio gain using the 16Rx coil could be demonstrated in the spine region both for a comparison with the 16TxRx coil (>50% gain) in vivo and the 32TxRx coil (>240% gain) in a phantom. The 16Rx coil was successfully applied to improve anatomical imaging in the abdomen and 2D spatially selective excitation in the spine of volunteers. CONCLUSION: The novel 16-channel Rx-array as an add-on to multichannel TxRx RF coil configurations provides increased signal-to-noise ratio, lower g-factors, and thus improves 7T ultra-high field body MR imaging.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Columna Vertebral/diagnóstico por imagen , Adulto , Diseño de Equipo , Humanos , Masculino , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA