RESUMEN
BACKGROUND: Most patients undergoing Transcatheter aortic valve implantation (TAVR) are elderly with significant co-morbidities and there is limited information available regarding factors that influence length of stay (LOS) post-procedure. The aim of this study was to identify the patient, and procedural factors that affect post-TAVR LOS using a contemporary multinational registry. METHODS: We conducted a retrospective cohort study, with patients recruited from three high volume tertiary institutions. The primary outcome was the LOS post-TAVR procedure. We examined patient and procedural factors in a cause-specific Cox multivariable regression model to elucidate their effect on LOS, accounting for the competing risk of post-procedural death. Hazard ratios (HR) greater than 1 indicate a shorter LOS, while HRs less than 1 indicate a longer LOS. RESULTS: The cohort consisted of 809 patients. Patient factors associated with longer LOS were older age, prior atrial fibrillation, and greater patient urgency. Patient factors associated with shorter LOS were lower NYHA class, higher ejection fraction and higher mean aortic valve gradients. Procedural characteristics associated with shorter LOS were conscious sedation (HR = 1.19, 95% CI 1.06-1.35, p = 0.004). Transapical access was associated with prolonged LOS (HR = 0.49, 95% CI 0.41-0.58, p < 0.001). CONCLUSION: This multicenter study identified potentially modifiable patient and procedural factors associated with a prolonged LOS. Future research is needed to determine if interventions focused on these factors will translate to a shorter LOS.
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Tiempo de Internación , Reemplazo de la Válvula Aórtica Transcatéter , Anestesia General , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Distribución de Chi-Cuadrado , Comorbilidad , Sedación Consciente , Hemodinámica , Mortalidad Hospitalaria , Hospitales de Alto Volumen , Humanos , Israel , Análisis Multivariante , Oportunidad Relativa , Ontario , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Factores de Riesgo , Centros de Atención Terciaria , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del TratamientoRESUMEN
INTRODUCTION AND OBJECTIVES: There are scarce data on the factors associated with impaired functional status after transcatheter aortic valve replacement (TAVR) and its clinical impact. This study aimed to determine the incidence, predictors, and prognostic implications of impaired functional class (NYHA class III-IV) following TAVR. METHODS: This multicenter study included 3462 transarterial TAVR patients receiving newer generation devices. The patients were compared according to their NYHA class at 1 month of follow-up (NYHA I-II vs NYHA III-IV). A multivariate logistic regression was performed to identify the predictors of 30-day NYHA class III-IV. Patient survival was compared with the Kaplan-Meier method and factors associated with decreased survival were identified with Cox regression analysis. RESULTS: The mean age of the study population was 80.3±7.3 years, with 47% of women, and a median Society of Thoracic Surgeons score of 3.8% [IQR, 2.5-5.8]. A total of 208 patients (6%) were in NYHA class III-IV 1 month after TAVR. Predictors of 30-day NYHA class III-IV were baseline NYHA class III-IV (OR, 1.76; 95%CI, 1.08-2.89; P=.02), chronic pulmonary obstructive disease (OR, 1.80; 95%CI, 1.13-2.83; P=.01), and post-TAVR severe mitral regurgitation (OR, 2.00; 95%CI, 1.21-3.31; P<.01). Patients in NYHA class III-IV 1 month after TAVR were at higher risk of death (HR, 3.68; 95%CI, 2.39-5.70; P<.01) and heart failure-related hospitalization (HR, 6.00; 95%CI, 3.76-9.60; P<.01) at 1-year follow-up. CONCLUSIONS: Up to 6% of contemporary TAVR patients exhibited an impaired functional status following TAVR. Worse baseline NYHA class, chronic pulmonary obstructive disease, and severe mitral regurgitation predicted 30-day NYHA class III/IV, and this determined a higher risk of mortality and heart failure hospitalization at 1-year follow-up. Further studies on the prevention and treatment optimization of patients with impaired functional status after TAVR are needed.
RESUMEN
BACKGROUND: The burden of cardiac death after transcatheter aortic valve replacement (TAVR), particularly from advanced heart failure (HF) and sudden cardiac death (SCD), remains largely unknown. OBJECTIVES: This study sought to evaluate the incidence and predictors of SCD and HF-related death in TAVR recipients treated with newer-generation devices. METHODS: This study included a total of 5,421 consecutive patients who underwent TAVR with newer-generation devices using balloon (75.7%) or self-expandable (24.3%) valves. RESULTS: After a median follow-up of 2 (IQR: 1-3) years, 976 (18.0%) patients had died, 50.8% from cardiovascular causes. Advanced HF and SCD accounted for 11.6% and 7.5% of deaths, respectively. Independent predictors of HF-related death were atrial fibrillation (HR: 2.17; 95% CI: 1.47-3.22; P < 0.001), prior pacemaker (HR: 1.79; 95% CI: 1.10-2.92; P = 0.01), reduced left ventricular ejection fraction (HR: 1.08 per 5% decrease; 95% CI: 1.01-1.14; P = 0.02), transthoracic approach (HR: 2.50; 95% CI: 1.37-4.55; P = 0.003), and new-onset persistent left bundle branch block (HR: 1.85; 95% CI: 1.14-3.02; P = 0.01). Two baseline characteristics (diabetes, HR: 1.81; 95% CI: 1.13-2.89; P = 0.01; and chronic kidney disease, HR: 1.72; 95% CI: 1.02-2.90; P = 0.04) and 3 procedural findings (valve in valve, HR: 2.17; 95% CI: 1.01-4.64; P = 0.04; transarterial nontransfemoral approach, HR: 2.23; 95% CI: 1.23-4.48; P = 0.01; and periprocedural ventricular arrhythmia, HR: 7.19; 95% CI: 2.61-19.76; P < 0.001) were associated with an increased risk of SCD after TAVR. CONCLUSIONS: Advanced HF and SCD accounted for a fifth of deaths after TAVR in contemporary practice. Potentially treatable factors leading to increased risk of HF deaths and SCD were identified, such as arrhythmia/dyssynchrony factors for HF and valve-in-valve TAVR or periprocedural ventricular arrhythmias for SCD.
Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Volumen Sistólico , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo , Función Ventricular Izquierda , Resultado del Tratamiento , Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugíaRESUMEN
BACKGROUND: The potential benefit of using larger or smaller transcatheter heart valves (THV) in patients with borderline aortic annulus measurement (BAM) remains uncertain. The objective of this study was to evaluate the clinical outcomes associated with the selection of larger or smaller THV in the context of BAM. METHODS: This was a multicenter observational study including patients who underwent transcatheter aortic valve replacement with the SAPIEN 3 or SAPIEN 3 Ultra-valve systems (Edwards Lifesciences, Irvine, CA) from April 2014 to June 2021. BAM was defined according to the manufacturer sizing chart and included the following annulus areas: 314 to 346, 400 to 430, 500 to 546 mm2. A 1:1 propensity score matching was used to compare outcomes of patients with larger or smaller THV. RESULTS: From a total of 2467 patients, BAM was identified in 852 patients (34.5%). A larger and smaller THV was selected in 338 (39.7%) and 514 patients (60.3%) patients, respectively. The choice of a larger THV was associated (before and after propensity matching) with a higher risk of new-onset left bundle branch block (HR, 2.25 [95% CI, 1.39-3.65; P=0.001) and permanent pacemaker implantation (HR, 1.86 [95% CI, 1.11-3.09]; P=0.016) without any impact on gradients or the risk of moderate or severe paravalvular regurgitation at discharge (HR, 0.78 [95% CI, 0.41-1.45]; P=0.427). The risk of periprocedural complications such as aortic rupture and tamponade was low (<1%) and similar between groups. CONCLUSIONS: In patient with BAM, selecting a larger SAPIEN 3/Ultra THV increased the risk of conduction disturbances without any benefit on valve hemodynamics and clinical outcomes.
Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Diseño de PrótesisRESUMEN
OBJECTIVES: The role of atrial myocytes and extracellular matrix (ECM) changes in atrial chamber remodeling was studied in a canine model of heart failure (HF). BACKGROUND: Cardiac remodeling is a key process mediating the progression of HF. Studies of the structural mechanisms of cardiac remodeling have been limited to the left ventricle. The structural alterations associated with atrial chamber remodeling in evolving HF have not been studied. METHODS: Age- and weight-matched dogs were subjected to right ventricular pacing (240 beats/min) for one and three weeks to produce early and severe HF, respectively. Atrial tissues were assessed for myocyte and ECM changes. RESULTS: Right atrial and left atrial (LA) pressures were significantly increased in early and severe HF. The LA wall tension index was significantly increased at both HF stages by 116% and 443%, respectively. Atrial collagen synthesis and degradation were significantly increased in severe HF. Gelatinase activity was significantly increased at both early and severe stages of HF. Gelatin zymography showed increased matrix metalloproteinases (MMP)-9 with early HF and increased MMP-2 with severe HF. The LA wall tension index was significantly correlated with gelatinase activity and collagen synthesis. Although total atrial collagen content was not changed, disarray of collagen fibers was observed. Atrial myocyte hypertrophy without evidence of apoptosis was also present in severe HF. CONCLUSIONS: There is marked atrial chamber remodeling in canine pacing-induced HF, which is characterized by myocyte hypertrophy and dynamic collagen turnover. Atrial remodeling may contribute to the development of atrial arrhythmias and pulmonary hypertension and could offer a novel therapeutic target.
Asunto(s)
Colágeno/metabolismo , Atrios Cardíacos/metabolismo , Atrios Cardíacos/fisiopatología , Insuficiencia Cardíaca/metabolismo , Insuficiencia Cardíaca/fisiopatología , Animales , Perros , Atrios Cardíacos/patología , Insuficiencia Cardíaca/diagnóstico por imagen , Hemodinámica , Masculino , UltrasonografíaRESUMEN
The role of the angiopoietin-1 (Ang1)-Tie2 pathway in the pathogenesis of pulmonary arterial hypertension (PAH) is controversial. Although Ang1 is well known to prevent endothelial activation and injury in systemic vascular beds, this pathway has been suggested to mediate pulmonary vascular remodeling in PAH. Therefore, we used transgenic models to determine the effect of increased or decreased Tie2 activity on the development of PAH. We now report modest spontaneous elevation in right ventricular systolic pressure in Tie2-deficient mice (Tie2(+/-)) compared with wild-type (WT) littermate controls, which was exacerbated upon chronic exposure to the clinically relevant PAH triggers, serotonin (5-HT) or interleukin-6 (IL-6). Moreover, overexpression of Ang1 in transgenic mice had no deleterious effect on pulmonary hemodynamics and, if anything, blunted the response to 5-HT. Exposure to 5-HT or IL-6 also decreased lung Ang1 expression, further reducing Tie2 activity and inducing pulmonary apoptosis in the Tie2(+/-) group only. Similarly, cultured pulmonary artery endothelial cells subjected to Tie2 silencing demonstrated increased susceptibility to apoptosis after 5-HT treatment. Finally, treatment of Tie2-deficient mice with Z-VAD, a pan-caspase inhibitor, prevented the pulmonary hypertensive response to 5-HT. Thus, these findings firmly establish that endothelial survival signaling via the Ang1-Tie2 pathway is protective in PAH.