RESUMEN
BACKGROUND AND AIMS: Data from randomized trials investigating different access closure strategies after transfemoral transcatheter aortic valve implantation (TF-TAVI) remain scarce. In this study, two vascular closure device (VCD) strategies to achieve hemostasis after TF-TAVI were compared. METHODS: The ACCESS-TAVI (Comparison of Strategies for Vascular ACCESS Closure after Transcatheter Aortic Valve Implantation) is a prospective, multicenter trial in which patients undergoing TF-TAVI were randomly assigned to a strategy with a combined suture-/plug-based VCD strategy (suture/plug group) using one ProGlideTM/ProStyleTM (Abbott Vascular) and one Angio-Seal® (Terumo) versus a suture-based VCD strategy (suture-only group) using two ProGlidesTM/ProStylesTM. The primary endpoint was a composite of major or minor access site-related vascular complications during index hospitalization according to Valve Academic Research Consortium (VARC)-3 criteria. Key secondary endpoints included time to hemostasis, VARC-3 bleeding type ≥2 and all-cause mortality over 30 days. RESULTS: Between September 2022 and April 2024, 454 patients were randomized. The primary endpoint occurred in 27% (62/230) in the suture/plug group and 54% (121/224) in the suture-only group (relative risk [RR] 0.55 [95% confidence interval: 0.44;0.68]; p<0.001). Time to hemostasis was significantly shorter in the suture/plug group compared to the suture-only group (108±208 s vs. 206±171 s; p <0.001). At 30 days, bleeding type ≥2 occurred less often in the suture/plug group compared to the sutureonly group (6.2% vs. 12.1%, RR 0.66 [0.43;1.02]; p=0.032), with no significant difference in mortality. CONCLUSIONS: With regard to the composite of major or minor access-related vascular complications, a combined suture-/plug-based VCD strategy was superior to a suturebased VCD strategy for vascular access closure in patients undergoing TF-TAVI.
RESUMEN
BACKGROUND: We previously showed non-inferiority of a low-dose paclitaxel-coated balloon (PCB) with citrate excipient (Agent PCB) as compared to normal-dose iopromide excipient (SeQuent Please PCB) in terms of angiographic and clinical endpoints at 12 months. The long-term clinical efficacy and safety of Agent PCB is not defined. METHODS: 262 patients (323 DES-ISR lesions) were enrolled in this study and treated with either Agent PCB (125 patients, 151 lesions) in the ISAR-DESIRE 3a trial or with SeQuent Please PCB (137 patients, 172 lesions) in the setting of the randomized ISAR-DESIRE 3 trial with similar in- and exclusion criteria serving as historical control arm. The follow-up period was extended to 7 years. The efficacy and safety endpoints of this analysis were target-lesion revascularization (TLR), death, myocardial infarction (MI) and target lesion thrombosis (TLT) at 7 years. RESULTS: At 7 years, 206 patients (78.6%) were alive. The risks of TLR (hazard ratio [HR]: 1.29, 95% confidence interval [CI]: 0.87-1.90; p = 0.205), death (HR: 1.38, 95% CI: 0.82-2.35; p = 0.227), MI (HR: 1.10, 95% CI: 0.39-3.15; p = 0.852) and TLT (HR: 2.18, 95% CI: 0.20-24.10; p = 0.523) were comparable between Agent PCB and SeQuent PCB. Multivariate analysis showed comparable risks of TLR, death and MI between both PCB devices. CONCLUSIONS: In patients treated for DES-ISR by angioplasty with Agent PCB and SeQuent Please PCB, there was no statistically significant difference in TLR at 7 years. Randomized trials with standardized lesion preparation and long-term follow-up are warranted to further evaluate comparative efficacy of both devices. (ClinicalTrials. gov Identifier: NCT02367495).
Asunto(s)
Angioplastia Coronaria con Balón , Catéteres Cardíacos , Fármacos Cardiovasculares , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Stents Liberadores de Fármacos , Paclitaxel , Intervención Coronaria Percutánea , Humanos , Masculino , Femenino , Paclitaxel/administración & dosificación , Paclitaxel/efectos adversos , Persona de Mediana Edad , Anciano , Factores de Tiempo , Resultado del Tratamiento , Reestenosis Coronaria/etiología , Reestenosis Coronaria/diagnóstico por imagen , Fármacos Cardiovasculares/administración & dosificación , Fármacos Cardiovasculares/efectos adversos , Angioplastia Coronaria con Balón/instrumentación , Angioplastia Coronaria con Balón/efectos adversos , Factores de Riesgo , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/efectos adversos , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Diseño de Prótesis , Infarto del Miocardio/etiología , Yohexol/efectos adversos , Yohexol/análogos & derivados , Yohexol/administración & dosificación , Ácido Cítrico/administración & dosificación , Ácido Cítrico/efectos adversos , Trombosis Coronaria/etiología , Estudios Prospectivos , Medios de Contraste/efectos adversos , Medios de Contraste/administración & dosificaciónRESUMEN
AIMS: We aimed to evaluate transcatheter mitral valve implantation (TMVI) using predominantly balloon-expandable transcatheter heart valves (THV) in patients with a landing zone for a percutaneously delivered prosthesis. BACKGROUND: Patients with a degenerated mitral valve bioprosthesis, annuloplasty ring, and mitral annulus calcification (MAC) considered at high surgical risk currently represent a treatment challenge. TMVI is an alternative treatment option. METHODS: Retrospective analysis of patients with symptomatic degenerated mitral valve bioprosthesis, or annuloplasty ring, and MAC treated with TMVI between November 2011 and April 2021. Endpoints were defined according to Mitral Valve Academic Research Consortium (MVARC) criteria and included device and procedure success at 30 days as well as mortality at 30 days and 1 year after the procedure. RESULTS: A total of 77 patients underwent TMVI (valve in valve [ViV = 56], valve in ring [ViR = 11], and valve in MAC [ViMAC = 10]). There was a trend toward higher technical success (all = 93.5%, ViV = 96.4%, ViR = 90.9%, ViMAC = 80%, p = 0.06) and lower 30-day (all = 11.7%, ViV = 10.7%, ViR = 9.1%, ViMAC = 20%, p = 0.49) and 1-year mortality (all = 26%, ViV = 23.2%, ViR = 27.3%, ViMAC= 40%, p = 0.36) after ViV and ViR compared to ViMAC. CONCLUSION: TMVI represents a reasonable treatment option in selected patients with MAC or who are poor candidates for redo mitral valve surgery. Technical success and survival up to 1 year were not significantly dependent on the subgroup in which TMVI was performed.
Asunto(s)
Bioprótesis , Calcinosis , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral , Válvula Mitral , Diseño de Prótesis , Humanos , Masculino , Estudios Retrospectivos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Femenino , Anciano , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Resultado del Tratamiento , Calcinosis/diagnóstico por imagen , Calcinosis/mortalidad , Calcinosis/cirugía , Calcinosis/fisiopatología , Factores de Tiempo , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Factores de Riesgo , Anciano de 80 o más Años , Anuloplastia de la Válvula Mitral/efectos adversos , Anuloplastia de la Válvula Mitral/instrumentación , Anuloplastia de la Válvula Mitral/mortalidad , Recuperación de la Función , Falla de Prótesis , Persona de Mediana Edad , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/mortalidad , Enfermedades de las Válvulas Cardíacas/fisiopatología , Medición de RiesgoRESUMEN
Aortic valve stenosis is one of the most frequent valvular heart diseases requiring treatment in industrialized countries. The symptom onset is associated with a significantly increased mortality, so that there is a clear indication for treatment in patients with severe, symptomatic aortic valve stenosis; however, data on the optimal treatment of patients with asymptomatic aortic valve stenosis are scarce. Smaller studies in the field of cardiac surgery suggest that early surgical valve replacement is superior to a conservative approach. For this reason, the results of additional adequately powered randomized trials are awaited with great interest. In this year numerous long-term results from randomized comparisons of the two available treatment options (surgical versus transcatheter aortic valve replacement) were published, which will further guide the heart team to find the best treatment approach for each individual.
Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de RiesgoRESUMEN
BACKGROUND: Transcatheter aortic valve implantation (TAVI) was established as a standard treatment for high-operative risk patients with severe aortic stenosis (AS). Although coronary artery disease (CAD) often coexists with AS, clinical and angiographic evaluations of stenosis severity are unreliable in this specific setting. To provide precise risk stratification of coronary lesions, combined near-infrared spectroscopy and intravascular ultrasound (NIRS-IVUS) was developed to integrate morphological and molecular information on plaque composition. However, there is a lack of evidence on the association between NIRS-IVUS derived findings such as maximum 4mm lipid core burden index (maxLCBI4mm) and clinical outcomes in AS patients undergoing TAVI. This registry aims to assess feasibility and safety of NIRS-IVUS imaging in the setting of routine pre-TAVI coronary angiography to improve assessment of CAD severity. METHODS: The registry is designed as a non-randomized, prospective, observational, multicenter cohort registry. Patients referred for TAVI with angiographic evidence of CAD receive NIRS-IVUS imaging and are followed up to 24 months. Enrolled patients are classified as NIRS-IVUS positive and NIRS-IVUS negative, respectively, based on their maxLCBI4mm to compare their clinical outcomes. The primary endpoint of the registry is major adverse cardiovascular events over a 24-month follow-up period. CONCLUSIONS: Identification of patients likely or unlikely to benefit from revascularization prior to TAVI represents an important unmet clinical need. This registry is designed to investigate whether NIRS-IVUS-derived atherosclerotic plaque characteristics can identify patients and lesions at risk for future adverse cardiovascular events after TAVI, in order to refine interventional decision-making in this challenging patient population.
Asunto(s)
Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Espectroscopía Infrarroja Corta/métodos , Estudios Prospectivos , Ultrasonografía Intervencional/métodos , Angiografía Coronaria , Sistema de RegistrosRESUMEN
BACKGROUND: Permanent pacemaker implantation (PPI) remains a relevant complication after transcatheter aortic valve implantation (TAVI) and its impact on outcome remains controversial. AIMS: This study aimed to analyze the effects of implantation depth on PPI at 30 days and assess its impact on outcome with the balloon-expandable Sapien 3 (S3) prosthesis. METHODS: Between 2014 and 2018, 849 patients without previous pacemaker undergoing transfemoral TAVI with the S3 were included. Prosthesis implantation depth was measured and divided into Quintiles. An ordinal logistic regression was used to assess its association with PPI, while a multivariate logistic regression was performed to identify predictors of PPI. Survival analyses were performed with the Kaplan-Meier method and a multivariable Cox regression was performed to ascertain the impact of PPI on mortality. RESULTS: Overall, incidence of PPI at 30 days was 9.7%. Implantation depth decreased consistently from a median of 6.7 mm [5.55-8.00] in 2014 to 2.7 mm [2.30-3.50] in 2018 (p < 0.001). When considering Quintiles of implantation depth, incidence of PPI was significantly higher in upper Quintiles and risk for PPI was significantly lower for the 1. Quintile compared to the 5. Quintile (OR: 0.34, 95% CI: [0.16-0.73]; p = 0.003). In the adjusted multivariable logistic regression implantation depth persisted ad independent predictor of PPI at 30 days. Patients requiring PPI at 30 days displayed significantly higher mortality at 4 years compared to patients without PPI (49.5% vs. 40.0%; log-rank = 0.022). In a multivariate analysis, increased logistic EuroScore, diabetes mellitus, and history of atrial fibrillation, were independent predictors of all-cause mortality at 2 years. CONCLUSIONS: Higher prosthesis implantation relative to the virtual aortic annulus was significantly associated with reduced risk for PPI at 30 days. Patients with PPI at 30 days exhibited higher mortality during follow-up, however, only logistic EuroScore, diabetes mellitus, and history of atrial fibrillation were identified as independent predictors of mortality at 2 years.
Asunto(s)
Estenosis de la Válvula Aórtica , Fibrilación Atrial , Diabetes Mellitus , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Fibrilación Atrial/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de RiesgoRESUMEN
OBJECTIVES: To investigate the feasibility and safety of percutaneous transluminal angioplasty (PTA) of the iliofemoral arteries (IFA) before transfemoral transcatheter aortic valve implantation (Tf-TAVI) in patients with advanced peripheral artery disease (PAD). BACKGROUND: Although Tf-TAVI represents the access of choice, alternative vascular access routes are preferred for patients displaying advanced PAD. PTA of the IFA represents a less invasive option, broadening the spectrum of patients eligible for Tf-TAVI. METHODS: All patients requiring PTA of the IFA before Tf-TAVI, between 2012 and 2021, were included. Primary efficacy endpoint was the rate of successful transcatheter heart valve (THV) delivery and implantation. Primary safety endpoint was the rate of PTA and access-site-related vascular complications, procedural- and in-hospital complications. RESULTS: Among 2726 Tf-TAVI procedures, 59 patients required IFA predilation. Successful THV delivery and implantation was achieved in 57 (96.6%) patients, respectively. Sheath placement was achieved in 59 (100%) patients with only one minor dissection and no major vascular complications following iliofemoral PTA. Regarding access site complications, two (3.4%) vessel perforations and one (1.7%) vessel rupture were observed, with eight (13.5%) patients requiring unplanned endovascular interventions. There was one intraprocedural death due to THV-induced vessel laceration, while in-hospital all-cause mortality was 8.5% in the present high-risk patient cohort. CONCLUSIONS: Predilation of IFA is safe and effective in patients with advanced PAD. Careful preprocedural planning is paramount in improving procedural safety and efficacy. This strategy has the potential to broaden the spectrum of patients eligible for Tf-TAVI.
Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad Arterial Periférica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Resultado del Tratamiento , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Enfermedad Arterial Periférica/complicacionesRESUMEN
OBJECTIVES: To evaluate the safety and efficacy of lesion preparation using rotational atherectomy (RA) with consecutive cutting balloon angioplasty (Rota-Cut). BACKGROUND: Whether the Rota-Cut combination improves stent performance in severely calcified coronary lesions is unknown. METHODS: PREPARE-CALC-COMBO is a single-arm prospective trial in which 110 patients were treated with a Rota-Cut strategy before implantation of sirolimus-eluting stents and compared with patients treated with modified balloon (MB, scoring or cutting) or RA from a historical cohort (the randomized PREPARE-CALC trial). The study had two primary endpoints: in-stent acute lumen gain (ALG) by quantitative angiographic analysis and stent expansion (SE) on optical coherence tomography. RESULTS: In-stent ALG was significantly higher with Rota-Cut compared to RA or MB alone (1.92 ± 0.45 mm vs. 1.74 ± 0.45 mm with MB vs. 1.70 ± 0.42 mm with RA; p = 0.001 and p < 0.001, respectively). SE was comparable between groups (75.1 ± 13.8% vs. 73.5 ± 13.3 with MB vs. 73.1 ± 12.2 with RA; p = 0.19 and p = 0.39, respectively). The Rota-Cut combination resulted in higher minimal stent area (MSA) (7.1 ± 2.2mm2 vs. 6.1 ± 1.7mm2 with MB vs. 6.2 ± 1.9mm2 with RA; p = 0.003 and p = 0.004, respectively). In-hospital death occurred in one patient. Target vessel failure at 9 months was low and comparable between groups (8.2% vs. 8% with MB vs. 6% with RA; p = 1 and p = 0.79, respectively). CONCLUSION: Rota-Cut combination resulted in higher ALG and larger MSA compared with historical control of RA or MB alone, but was not associated with higher SE. Despite extensive lesion preparation, this strategy is safe, feasible, and associated with favorable clinical outcome at 9 months.
Asunto(s)
Angioplastia Coronaria con Balón , Aterectomía Coronaria , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Calcificación Vascular , Humanos , Aterectomía Coronaria/efectos adversos , Aterectomía Coronaria/métodos , Estudios Prospectivos , Mortalidad Hospitalaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Angiografía Coronaria , Resultado del Tratamiento , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/métodos , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/terapia , Calcificación Vascular/etiologíaRESUMEN
OBJECTIVES: The present study aims to analyze the angiographic anti-restenotic performance of durable polymer everolimus-eluting stents (EES) for the treatment of in-stent restenosis (ISR) in daily practice. BACKGROUND: Randomized data is available supporting the use of drug-coated balloons and drug-eluting stents for the treatment of ISR; however, additional real-world data including angiographic follow-up is needed. METHODS: Patients who underwent EES-implantation for the treatment of drug-eluting stent ISR and attended for a 6-8 months angiographic surveillance were analyzed. Off-line assessment of the angiograms was conducted at a central quantitative coronary angiographic core laboratory. RESULTS: A total of 426 patients with ISR were treated with EES and had undergone angiographic follow-up. The mean age was 66.8 ± 9.9 years and 27.5% suffered from diabetes. A total of 459 lesions were treated. The diameter stenosis decreased from 64.3 ± 19.1% (preprocedural) to 12.0 ± 6.4% (postprocedural). At 6-8 months angiographic follow-up, the in-segment diameter stenosis was 38.3 ± 21.7% and the in-stent late luminal loss was 0.54 ± 0.74 mm in the treated area analysis. The rate of recurrent binary restenosis was 25.7%. CONCLUSIONS: In the setting of ISR, the angiographic anti-restenotic efficacy of stenting with EES is comparable to that observed in randomized clinical trials and less favorable than its performance in patients undergoing stenting for de novo disease.
Asunto(s)
Angioplastia Coronaria con Balón , Reestenosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Anciano , Constricción Patológica , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Everolimus , Humanos , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , Stents , Resultado del TratamientoRESUMEN
AIM: Psoas muscle cross-sectional area (CSA) is a proposed marker of frailty associated with mortality after transcatheter aortic valve implantation (TAVI). We assessed the impact of psoas CSA on medium-term mortality over 5 years in a large cohort, adjusted for pre-procedural variables. METHOD: This single-centre registry-derived analysis assessed 1,731 consecutive TAVI patients between 2007 and 31 April 2015 with available abdominal computed tomography scans. Sex-stratified, height-adjusted psoas CSA was measured mid-body of the fourth lumbar vertebra. Kaplan-Meier survival distributions across psoas CSA quartiles were compared. Cox and logistic regression models were used to assess baseline variables associated with the primary outcome, which was mortality within 5 years. RESULTS: Median age was 81 years (interquartile range, 77 - 85); 52.5% were women. The primary endpoint occurred in 555 patients over a mean follow-up of 775 days. Lower psoas CSA quartile patients were older, had a lower body mass index, lower creatinine clearance, and lower rates of previous cardiac surgery, with higher rates of diabetes, coronary artery disease, pacemaker, anaemia, hypoalbuminaemia, and higher European System for Cardiac Operative Risk Evaluation (EuroSCORE). Unadjusted survival by psoas CSA quartile was significantly different in men (log rank p=0.041) but not women (p=0.099). In Bonferroni-adjusted multivariate analysis, psoas CSA quartiles were not significantly associated with mortality. Hypoalbuminaemia (hazard ratio [HR], 2.10; 95% confidence interval [CI], 1.53 - 2.87 [p<0.001]) and increasing age (HR, 1.03 per year; 95% CI, 1.01 - 1.05 [p=0.002]) were associated with increased risk; female sex (HR, 0.63; 95% CI 0.51 - 0.78 [p<0.001]), and hypercholesterolaemia (HR, 0.67; 95%, CI 0.54 0.83 [p<0.001]) with reduced risk. CONCLUSIONS: Psoas CSA was not significantly associated with mortality after adjusting for pre-procedural variables. Hypoalbuminaemia, sex, hypercholesterolaemia, and age were significantly associated with mortality after TAVI.
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Músculos Psoas/diagnóstico por imagen , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Humanos , Masculino , Músculos Psoas/cirugía , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Factores de Tiempo , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del TratamientoRESUMEN
OBJECTIVES: To evaluate 1-year outcome using the ACURATE neo (Symetis S.A., a Boston Scientific Company, Ecublens, Switzerland) according to the updated Valve Academic Research Consortium (VARC-2) with emphasis on the composite endpoints "clinical efficacy after 30 days" and "time-related valve safety". BACKGROUND: Initial reports on the clinical performance of patients treated with the ACURATE neo are promising; however, information regarding one-year outcome is scarce, especially with regard to the composite endpoints proposed by the VARC-2. METHODS: One hundred and fifty one consecutive patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) with the ACURATE neo for severe aortic valve stenosis were enrolled. Data were prospectively collected and event rates during follow-up were calculated as the Kaplan-Meier estimates. RESULTS: Mean age was 81.1 ± 5.9 years and 49.7% (75/151) were female with a median logistic EuroScore of 13.8% [8.2-20.5]. Device success was achieved in 88.1% (133/151) and procedure related mortality was 0.7% (1/151). At one-year, all-cause mortality was 3.3% (5/151), while permanent pacemaker implantation occurred in 12.7% (19/151) of patients. The "clinical efficacy after 30 days" was observed in 24.8% (37/151), where the main contributor was symptom worsening in 14.8% (22/151) of cases. "Time-related valve safety" occurred in 22.0% (33/151) with structural valve deterioration as main contributor in 10.7% (16/151) of cases. CONCLUSIONS: Using the ACURATE neo, we found a favorable safety profile with low all-cause mortality at 1 year. The reported VARC-2 defined composite endpoints at 1 year reveal low rates of "clinical efficacy after 30 days" and "time-related valve safety".
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Hemodinámica , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del TratamientoRESUMEN
BACKGROUND: Although the incidence of periprocedural complications has decreased in transcatheter aortic valve implantation (TAVI), life-threatening complications occur and emergency veno-arterial extracorporeal membrane oxygenation (vaECMO) can provide immediate circulatory stabilization. We report our two-center experience of vaECMO during life-threatening complications in TAVI. METHODS: From January 2010 to December 2015, 1,810 consecutive patients underwent TAVI at two centers. Clinical characteristics, type of complication, outcome and temporal trends in the requirement of emergency vaECMO were evaluated. RESULTS: Life-threatening complications requiring vaECMO occurred in 1.8% of cases (33 patients; 22 transfemoral, 11 transapical). Indications for vaECMO were ventricular rupture (30%, 10/33), low output (15%, 5/33), bleeding (12%, 4/33), coronary artery impairment (9%, 3/33), ventricular arrhythmias (6%, 2/33), severe aortic regurgitation (6%, 2/33), aortic annular rupture (6%, 2/33), and aortic dissection (3%, 1/33). In 4 cases, no definite cause for hemodynamic instability was identified. Conversion to open heart surgery was necessary in 42% of patients (14/33). Percutaneous coronary intervention was performed in all cases with coronary artery impairment (9%, 3/33). Patients with severe aortic regurgitation (6%, 2/33) underwent emergency valve-in-valve implantation. Other patients received, in addition to vaECMO support conservative treatment (42%, 14/33). In-hospital mortality and 30-day mortality were 46% (15/33). Of patients discharged, 67% (12/18) had no neurological impairment, whereas mild and severe neurological impairment was found in 11% (2/18) and 22% (4/18), respectively. From 2010 to 2015, with increasing procedures (from n = 43 to n = 553) requirement of vaECMO decreased from 9.3% to 0.9% (P for the trend <0.001). CONCLUSION: Over a 6-year period, need for emergency vaECMO during TAVI significantly decreased over time. Despite high in-hospital mortality, vaECMO represents a feasible strategy for hemodynamic support in case of life-threatening complications.
Asunto(s)
Válvula Aórtica/cirugía , Oxigenación por Membrana Extracorpórea , Enfermedades de las Válvulas Cardíacas/cirugía , Complicaciones Posoperatorias/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Urgencias Médicas , Oxigenación por Membrana Extracorpórea/efectos adversos , Oxigenación por Membrana Extracorpórea/mortalidad , Femenino , Alemania , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/mortalidad , Enfermedades de las Válvulas Cardíacas/fisiopatología , Mortalidad Hospitalaria , Humanos , Incidencia , Masculino , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/mortalidad , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del TratamientoRESUMEN
PURPOSE: Elevated carbohydrate antigen 125 (CA125) predicts adverse outcome after transcatheter aortic valve implantation (TAVI). While known underlying pathophysiological mechanisms of elevated CA125 include serosal effusions and inflammatory stimuli, clinical determinants associated with elevated CA125 in patients referred for TAVI remain unknown. Therefore, we investigated clinical, laboratory and echocardiographic determinants of elevated CA125 in patients with severe aortic valve stenosis referred for TAVI. METHODS: This study includes 650 patients with severe aortic stenosis referred for TAVI. Baseline CA125 was determined by an immunoassay and dichotomized (elevated versus normal) based on the manufacturer cutoff value (>35 U/mL). RESULTS: CA125 elevation was present in 28% (181/650). Patients with elevated CA125 had an overall worse clinical profile and were more symptomatic with a higher rate of NYHA class III/IV (80% versus 58%; p < 0.001). In a multivariate analysis, independent predictors of elevated CA125 were New York Heart Association (NYHA) class, baseline hemoglobin, C-reactive protein (CRP), left ventricular ejection fraction and severe tricuspid regurgitation. CONCLUSION: Elevated CA125 levels in patients referred for TAVI summarize a subset of patients with an overall worse clinical profile who are more symptomatic.
Asunto(s)
Estenosis de la Válvula Aórtica/sangre , Antígeno Ca-125/sangre , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Proteína C-Reactiva , Hemoglobinas , Humanos , Medición de Riesgo , Factores de Riesgo , Insuficiencia de la Válvula Tricúspide , Función Ventricular IzquierdaRESUMEN
The treatment of in-stent restenosis after drug-eluting stent (DES) implantation remains a major clinical challenge. Optical coherence tomography (OCT) imaging at the time of presentation can provide important information on mechanical factors contributing to stent failure as well as on tissue characteristics of the in-stent neointimal tissue. We report a case of markedly different tissue types-characterized by heterogeneous and homogeneous signal intensity-observed in a patient with multiple lesion DES in-stent restenosis. Although both lesions were initially successfully treated with drug-coated balloon angioplasty, the patient presented with recurrent in-stent restenosis in the lesion with homogeneous tissue characteristics. Future studies should evaluate whether OCT tissue characterization can guide optimal treatment strategy in patients with DES restenosis. © 2016 Wiley Periodicals, Inc.
Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Tomografía de Coherencia Óptica , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Recurrencia , Resultado del TratamientoRESUMEN
BACKGROUND: Improved outcomes in patients with diabetes mellitus undergoing percutaneous coronary intervention remain an unmet clinical need. We assessed the long-term efficacy and safety of novel polymer-free sirolimus- and probucol-eluting stent in diabetic patients enrolled in intracoronary stenting and angiographic results: test efficacy of sirolimus- and probucol-eluting versus zotarolimus-eluting stents 5 trial. METHODS: In a pre-specified subgroup analysis, outcomes of diabetic patients treated with a sirolimus- and probucol-eluting stent or a second-generation zotarolimus-eluting stent were compared. The primary endpoint was a device-oriented composite outcome comprising cardiac death, target vessel-related myocardial infarction (MI), or target lesion revascularization (TLR) at 5-year follow-up. Event-free survival was assessed using the Kaplan-Meier method. Hazard ratios (HR) and 95 % confidence intervals (CI) were estimated from univariate Cox proportional hazards models. RESULTS: A total of 870 patients with diabetes mellitus were treated with either a sirolimus- and probucol-eluting stent (n = 575) or a second-generation zotarolimus-eluting stent (n = 295). At 5 years, the rate of device-oriented composite endpoint was comparable between the sirolimus- and probucol-eluting stent and the second-generation zotarolimus-eluting stent (32.9 versus 33.4 %, HR 0.88, 95 % CI 0.76-1.26). No significant differences were observed between the sirolimus- and probucol-eluting stent and the second-generation zotarolimus-eluting stent groups in the incidence of cardiac death (15.6 versus 16.7 % HR 0.92, 95 % CI 0.63-1.32), target-vessel MI (4.6 versus 6.6 %, HR 0.73, 95 % CI 0.40-1.34), and TLR (18.6 versus 18.8 %, HR 1.00, 95 % CI, 0.72-1.41). The rate of definite or probable stent thrombosis was low and similar in both groups (2.5 versus 2.6 %, HR 1.02, 95 % CI, 0.41-2.52). CONCLUSIONS: In patients with diabetes the long-term efficacy and safety of a polymer-free sirolimus- and probucol-eluting stent were comparable to a second-generation durable polymer zotarolimus-eluting stent. Trial registration ClinicalTrials.gov NCT00598533. Registered 10 January 2008.
Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedades Cardiovasculares/terapia , Angiopatías Diabéticas/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Probucol/administración & dosificación , Sirolimus/análogos & derivados , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedades Cardiovasculares/diagnóstico por imagen , Enfermedades Cardiovasculares/mortalidad , Angiografía Coronaria , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Trombosis Coronaria/etiología , Trombosis Coronaria/terapia , Angiopatías Diabéticas/diagnóstico por imagen , Angiopatías Diabéticas/mortalidad , Supervivencia sin Enfermedad , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Inhibidores de Agregación Plaquetaria/uso terapéutico , Probucol/efectos adversos , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Retratamiento , Factores de Riesgo , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: Lesion preparation with a cutting (CB) or scoring balloon (SB) is often used in patients with in-stent restenosis (ISR). However, there are no comparative studies. METHODS: We analyzed 81 patients (CB group: n = 38; SB group: n = 43) who had a calcified ISR from November 2019 to September 2021. The primary endpoint was strategy success (less than 20% residual stenosis); the secondary endpoints were major adverse cardiovascular events during the 1-year follow-up. Quantitative coronary angiography was performed to evaluate the strategy success. RESULTS: The patients in the CB group were more likely to have a severe calcified ISR (P = .001) and multiple stent layers (P = .001). A total of 4 patients (79.0%) reached the primary endpoint. Residual stenosis greater than 20% was more common in the CB group (39.5% vs 4.7%; P = .001). In the multivariate analysis, an effect of the intervention group on the achievement of the primary endpoint could be excluded (estimate 1.06; standard error 1.07; P = .322). The time interval of stent implantation prior to CB/SB (P = .007) and severe calcified ISR (P = .009) had a negative impact on reaching the primary endpoint. During the follow-up, there were no differences in rates of cardiac death (CB 2.5% vs. SB 1.2%; P = .598), acute myocardial infarction (CB 0% vs. SB 4.9%; P = .119), and target lesion failure (CB 3.7% vs SB 12.3%; P = .074). CONCLUSIONS: In our cohort, multivariate analysis showed that lesion preparation with CB or SB must be considered equivalent in terms of angiographic results. Factors like severe calcified ISR and the time interval of prior stent implantation negatively influenced the angiographic outcome.
Asunto(s)
Angioplastia Coronaria con Balón , Angiografía Coronaria , Reestenosis Coronaria , Humanos , Masculino , Femenino , Angiografía Coronaria/métodos , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/etiología , Anciano , Angioplastia Coronaria con Balón/métodos , Angioplastia Coronaria con Balón/efectos adversos , Estudios Retrospectivos , Estudios de Seguimiento , Persona de Mediana Edad , Stents/efectos adversos , Resultado del Tratamiento , Factores de Tiempo , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugíaRESUMEN
BACKGROUND: Modified balloon angioplasty (MB) using a cutting-/scoring balloon or intravascular lithotripsy (IVL) is used in patients with in-stent restenosis (ISR). However, IVL is an off-label use in this setting. The aim of this subgroup analysis of an all-comers registry was to compare IVL to MB angioplasty in patients with ISR. METHODS: The subgroup (n = 117) included all patients with an ISR treated by MB or IVL between 2019 and 2021. Primary endpoint was strategy success (< 20% residual stenosis). The secondary endpoint was cardiac death, acute myocardial infarction (AMI) and target lesion failure/revascularization (TVR). Quantitative coronary angiography was performed in all patients. RESULTS: A total of n = 36 patients were treated by IVL and n = 81 patients by MB. No significant differences in baseline characteristics were observed between the groups. The primary endpoint was reached in 99 patients (84.6%). Patients in the IVL group had less residual stenosis (2.8% vs. 21.0%; p = 0.012). Multivariate regression analysis revealed that IVL had a significant positive effect on reaching the primary end point (Estimate 2.857; standard error (SE) 1.166; p = 0.014). During the follow-up period (450 days) there were no significant differences in rates of cardiac death (IVL n = 2 (1.7%) vs. MB n = 3 (2.6%); p = 0.643), AMI (IVL n = 2 (1.7%) vs. MB n = 4 (3.4%); p = 0.999) and TVR (IVL n = 5 (4.3%) vs. MB n = 14 (12%); p = 0.851). CONCLUSION: IVL results in a significantly lower rate of residual stenosis than MB in patients with ISR. During the long-term follow-up, no differences in rates of cardiac death, AMI or TVR were observed.
Asunto(s)
Angioplastia Coronaria con Balón , Reestenosis Coronaria , Litotricia , Sistema de Registros , Humanos , Masculino , Femenino , Anciano , Reestenosis Coronaria/etiología , Angioplastia Coronaria con Balón/métodos , Resultado del Tratamiento , Persona de Mediana Edad , Litotricia/métodos , Stents , Angiografía Coronaria , Estudios de Seguimiento , Factores de Tiempo , Estudios RetrospectivosRESUMEN
BACKGROUND: In the PREPARE-CALC trial, severely calcified lesion preparation with rotational atherectomy (RA) before biodegradable polymer sirolimus-eluting stent (SES) implantation demonstrated higher procedural success and comparable rates of acute lumen gain and late lumen loss compared to modified balloons (MB) (scoring/cutting). We aimed to analyze the 5-year outcomes of both lesion preparation strategies. METHODS: PREPARE-CALC randomly assigned 200 patients 1:1 to MB or RA, followed by SES implantation. The principal endpoint of the current analysis was target vessel failure (TVF) at 5 years. RESULTS: At 5 years, MB had comparable rates of TVF to RA (19% vs. 21%, HR 1.14, 95% CI 0.60-2.16, p = 0.687). Subgroup analysis showed a lesion length treatment interaction, favoring MB for short lesions and RA for long ones (p for interaction = 0.042). Target lesion revascularization (TLR) was significantly less common with RA (12 vs. 3%, HR 0.28, 95% CI 0.08-0.98, p = 0.048). In a multivariate analysis, RA was independently protective against TLR (adj. HR 0.17, 95% CI 0.04-0.78, p = 0.022), while ostial lesions were associated with higher TLR independent of treatment strategy (adj. HR 11.3, 95% CI 2.98-42.6, p < 0.001). CONCLUSION: In patients with severely calcified coronary lesions, using MB or RA for lesion preparation followed by biodegradable polymer SES implantation was associated with comparable rates of TVF at 5 years. However, a significant reduction of TLR was observed after RA. PREPARE-CALC is the first randomized trial showing potential clinical advantages of RA over MB during long-term follow-up. CLINICAL TRIAL REGISTRATION: URL: https://www. CLINICALTRIALS: gov . Unique identifier: NCT02502851.
Asunto(s)
Angioplastia Coronaria con Balón , Aterectomía Coronaria , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Calcificación Vascular , Humanos , Aterectomía Coronaria/métodos , Masculino , Femenino , Anciano , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Resultado del Tratamiento , Calcificación Vascular/terapia , Calcificación Vascular/diagnóstico , Calcificación Vascular/cirugía , Angioplastia Coronaria con Balón/métodos , Angioplastia Coronaria con Balón/instrumentación , Factores de Tiempo , Angiografía Coronaria , Estudios de Seguimiento , Persona de Mediana Edad , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Implantes AbsorbiblesRESUMEN
OBJECTIVES: Systemic inflammatory response syndrome (SIRS) is a common finding after cardiovascular interventions. Data on the incidence of SIRS and its impact on outcome in patients undergoing transcatheter edge-to-edge mitral valve repair (MV-TEER) for mitral regurgitation (MR) is lacking. METHODS: From January 2013 to December 2020, 373 patients with moderate or severe MR undergoing MV-TEER were included. SIRS was defined as at least two of the following criteria within 48 h after the procedure: leucocyte count > 12.0 or < 4.0 × 109/l, respiratory rate > 20 breaths per minute or PaCO2 ≤ 4.3 kPa/32 mmHg, heart rate > 90 bpm and temperature > 38.0 °C or < 36.0 °C. The primary endpoint was 3-years all-cause mortality. RESULTS: SIRS was observed in 49.6% (185/373) of patients. Patients who developed SIRS presented more frequently with NYHA III/IV at baseline [SIRS: 82.4% (149/185) vs. no SIRS: 79.0% (147/188); p = 0.029]. Patients who developed SIRS spent more days on ICU (p < 0.001) and overall length of stay was longer (p < 0.001). Relevant residual MR, defined as MR ≥ III in-hospital, was present more often in patients who developed SIRS [SIRS: 11.3% (20/177) vs. no SIRS: 3.93% (7/178), p = 0.036]. At 3 years, all-cause mortality in the entire population was 33.5% (125/373) with an increased all-cause mortality in patients with SIRS compared to patients without SIRS (HR 1.49, [CI 95% 1.04, 2.13]; p = 0.0264). In the multivariate analysis development of SIRS (HR 1.479 [CI 95% 1.016, 2.154]; p = 0.041) was identified as predictor for 3-years all-cause mortality. CONCLUSIONS: SIRS is a common finding after MV-TEER occurring in approximately half of patients. SIRS after MV-TEER was associated with a longer in-hospital stay. In addition, we observed an increased 3-years all-cause mortality in patients with SIRS.
Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Incidencia , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Síndrome de Respuesta Inflamatoria Sistémica/diagnóstico , Síndrome de Respuesta Inflamatoria Sistémica/epidemiología , Síndrome de Respuesta Inflamatoria Sistémica/etiología , Frecuencia Cardíaca , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversosRESUMEN
BACKGROUND: Treatment of patients with recurrence of in-stent restenosis (ISR) remains particularly challenging, with data and guideline recommendations for repeat percutaneous coronary intervention being scant. OBJECTIVES: The aim of this study was to investigate the long-term incidence of recurrent revascularization events after percutaneous treatment of drug-eluting stent (DES) ISR. METHODS: In this post hoc analysis, 402 patients (500 lesions) assigned to plain balloon (PB), drug-coated balloon (DCB), or DES treatment in the randomized ISAR-DESIRE 3 (Efficacy Study of Paclitaxel-Eluting Balloon, -Stent vs. Plain Angioplasty for Drug-Eluting Stent Restenosis) trial were followed up over a median of 10.3 years. The primary endpoint was total repeat target lesion revascularization (R-TLR) including all, first and recurrent, events. RESULTS: At the end of follow-up, first R-TLR was required in 204 lesions, 82 in the PB group, 70 in the DCB group, and 52 in the DES group. The total number of R-TLRs was 373: 162 in the PB group, 124 in the DCB group, and 87 in the DES group. During the first year of follow-up, the risk for total R-TLR was reduced by DCB (HR: 0.36; 95% CI: 0.24-0.54) and DES (HR: 0.23; 95% CI: 0.14-0.38) treatment compared with PB treatment. After 1 year, the risk for total R-TLR was nonsignificantly reduced by DCB treatment (HR: 0.77; 95% CI: 0.51-1.16) and significantly reduced by DES treatment (HR: 0.61; 95% CI: 0.39-0.95) compared with PB treatment. Risk in the DCB and DES groups was similar during (HR: 1.54; 95% CI: 0.89-2.69) and after (HR: 1.26; 95% CI: 0.82-1.92) 1 year. CONCLUSIONS: The total number of R-TLRs over 10 years after treatment of patients with DES ISR was high. DCBs and particularly DES were able to reduce the need for both first and recurrent revascularization compared with PB treatment.