Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Vasc Interv Radiol ; 34(7): 1157-1165.e8, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36972846

RESUMEN

PURPOSE: To investigate the real-world safety of paclitaxel (PTX)-coated devices for treating lower extremity peripheral artery disease using a commercial claims database. MATERIALS AND METHODS: Data from FAIR Health, the largest commercial claims data warehouse in the United States, were used for this study. The study consisted of patients who underwent femoropopliteal revascularization procedures between January 1, 2015, and December 31, 2019, with PTX and non-PTX devices. The primary outcome was 4-year survival following treatment. The secondary outcomes included 2-year survival, 2- and 4-year freedom from amputation, and repeat revascularization. Propensity score matching was used to minimize confounding, and the Kaplan-Meier methods were used to estimate survival. RESULTS: A total of 10,832 procedures were included in the analysis, including 4,962 involving PTX devices and 5,870 involving non-PTX devices. PTX devices were associated with a reduced hazard of death following treatment at 2 and 4 years (hazard ratio [HR], 0.74 [95% confidence interval {CI}, 0.69-0.79]; P <.05, and HR, 0.89 [95% CI, 0.77-1.02]; log-rank P =.018, respectively). The risk of amputation was also lower following treatment with PTX devices than with non-PTX devices at 2 and 4 years (HR, 0.82 [95% CI, 0.76-0.87]; P =.02, and HR, 0.77 [95% CI, 0.67-0.89]; log-rank P =.01, respectively). In addition, the odds of repeat revascularization were similar with PTX and non-PTX devices at 2 and 4 years. CONCLUSIONS: In the real-world commercial claims database, no short- or long-term signal for increased mortality or amputations was observed following treatment with PTX devices.


Asunto(s)
Fármacos Cardiovasculares , Stents Liberadores de Fármacos , Procedimientos Endovasculares , Enfermedad Arterial Periférica , Humanos , Paclitaxel/efectos adversos , Arteria Poplítea , Resultado del Tratamiento , Fármacos Cardiovasculares/efectos adversos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Arteria Femoral , Grado de Desobstrucción Vascular
2.
N Engl J Med ; 376(6): 526-535, 2017 02 09.
Artículo en Inglés | MEDLINE | ID: mdl-28121489

RESUMEN

BACKGROUND: The process of assuring the safety of medical devices is constrained by reliance on voluntary reporting of adverse events. We evaluated a strategy of prospective, active surveillance of a national clinical registry to monitor the safety of an implantable vascular-closure device that had a suspected association with increased adverse events after percutaneous coronary intervention (PCI). METHODS: We used an integrated clinical-data surveillance system to conduct a prospective, propensity-matched analysis of the safety of the Mynx vascular-closure device, as compared with alternative approved vascular-closure devices, with data from the CathPCI Registry of the National Cardiovascular Data Registry. The primary outcome was any vascular complication, which was a composite of access-site bleeding, access-site hematoma, retroperitoneal bleeding, or any vascular complication requiring intervention. Secondary safety end points were access-site bleeding requiring treatment and postprocedural blood transfusion. RESULTS: We analyzed data from 73,124 patients who had received Mynx devices after PCI procedures with femoral access from January 1, 2011, to September 30, 2013. The Mynx device was associated with a significantly greater risk of any vascular complication than were alternative vascular-closure devices (absolute risk, 1.2% vs. 0.8%; relative risk, 1.59; 95% confidence interval [CI], 1.42 to 1.78; P<0.001); there was also a significantly greater risk of access-site bleeding (absolute risk, 0.4% vs. 0.3%; relative risk, 1.34; 95% CI, 1.10 to 1.62; P=0.001) and transfusion (absolute risk, 1.8% vs. 1.5%; relative risk, 1.23; 95% CI, 1.13 to 1.34; P<0.001). The initial alerts occurred within the first 12 months of monitoring. Relative risks were greater in three prespecified high-risk subgroups: patients with diabetes, those 70 years of age or older, and women. All safety alerts were confirmed in an independent sample of 48,992 patients from April 1, 2014, to September 30, 2015. CONCLUSIONS: A strategy of prospective, active surveillance of a clinical registry rapidly identified potential safety signals among recipients of an implantable vascular-closure device, with initial alerts occurring within the first 12 months of monitoring. (Funded by the Food and Drug Administration and others.).


Asunto(s)
Seguridad de Equipos , Intervención Coronaria Percutánea/instrumentación , Dispositivos de Cierre Vascular/efectos adversos , Anciano , Diseño de Equipo , Seguridad de Equipos/estadística & datos numéricos , Femenino , Hemorragia/epidemiología , Hemorragia/etiología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Vigilancia de la Población , Estudios Prospectivos , Sistema de Registros , Riesgo , Medición de Riesgo/métodos
3.
J Health Care Finance ; 2016(Spec Features)2016.
Artículo en Inglés | MEDLINE | ID: mdl-28280294

RESUMEN

Approved medical devices frequently undergo FDA mandated post-approval studies (PAS). However, there is uncertainty as to the value of PAS in assessing the safety of medical devices and the cost of these studies to the healthcare system is unknown. Since PAS costs are funded through device manufacturers who do not share the costs with regulators, we sought to estimate the total PAS costs through interviews with a panel of experts in medical device clinical trial design in order to design a general cost model for PAS which was then applied to the FDA PAS. A total of 277 PAS were initiated between 3/1/05 through 6/30/13 and demonstrated a median cost of $2.16 million per study and an overall cost of $1.22 billion over the 8.25 years of study. While these costs are funded through manufacturers, the ultimate cost is borne by the healthcare system through the medical device costs. Given concerns regarding the informational value of PAS, the resources used to support mandated PAS may be better allocated to other approaches to assure safety.


Asunto(s)
Costos y Análisis de Costo , Aprobación de Recursos , United States Food and Drug Administration , Diseño de Equipo , Humanos , Seguridad , Estados Unidos
4.
Med Devices (Auckl) ; 17: 97-105, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38434149

RESUMEN

Objective: To demonstrate the use of the Data Extraction and Longitudinal Trend Analysis (DELTA) system in the National Evaluation System for health Technology's (NEST) medical device surveillance cloud environment by analyzing coronary stent safety using real world clinical data and comparing results to clinical trial findings. Design and Setting: Electronic health record (EHR) data from two health systems, the Social Security Death Master File, and device databases were ingested into the NEST cloud, and safety analyses of two stents were performed using DELTA. Participants and Interventions: This is an observational study of patients receiving zotarolimus drug-eluting coronary stents (ZES) or everolimus eluting coronary stents (EES) between July 1, 2015 and December 31, 2017. Results: After exclusions, 3334 patients receiving EES and 1002 receiving ZES were available for study. Analysis using inverse probability weighting showed no significant difference in one-year mortality or major adverse cardiac events (MACE) for EES compared to ZES [Mortality Odds Ratio 0.94 (95% CI 0.81-1.175); p = 0.780] [MACE Odds Ratio 1.04 (95% CI 0.92-1.16; p = 0.551]). Analysis using propensity matching showed no significant difference in EES one-year mortality (547 of 992 alive and available after censoring) compared to ZES (546 of 992) [Log-Rank statistic 0.3348 (p = 0.563)]. Conclusion: Automated cloud-based medical device safety surveillance using EHR data is feasible and was efficiently performed using DELTA. No statistically significant differences in 1-year safety outcomes between ZES and EES were identified using two statistical approaches, consistent with randomized trial findings.

5.
Proc Natl Acad Sci U S A ; 106(40): 17111-6, 2009 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-19805189

RESUMEN

The CHEK2 kinase (Chk2 in mouse) is a member of a DNA damage response pathway that regulates cell cycle arrest at cell cycle checkpoints and facilitates the repair of dsDNA breaks by a recombination-mediated mechanism. There are numerous variants of the CHEK2 gene, at least one of which, CHEK2*1100delC (SNP), associates with breast cancer. A mouse model in which the wild-type Chk2 has been replaced by a Chk2*1100delC allele was tested for elevated risk of spontaneous cancer and increased sensitivity to challenge by a carcinogenic compound. Mice homozygous for Chk2*1100delC produced more tumors than wild-type mice, whereas heterozygous mice were not statistically different. When fractionated by gender, however, homozygous and heterozygous mice developed spontaneous tumors more rapidly and to a far greater extent than wild-type mice, indicative of a marked gender bias in mice harboring the variant allele. Consistent with our previous data showing elevated genomic instability in mouse embryonic fibroblasts (MEFs) derived from mice homozygous for Chk2*1100delC, the level of Cdc25A was elevated in heterozygous and homozygous MEFs and tumors. When challenged with the carcinogen 7,12-dimethylbenz[a]anthracene, all mice, regardless of genotype, had a reduced lifespan. Latency for mammary tumorigenesis was reduced significantly in mice homozygous for Chk2*1100delC but unexpectedly increased for the development of lymphomas. An implication from this study is that individuals who harbor the variant CHEK2*1100delC allele not only are at an elevated risk for the development of cancer but also that this risk can be further increased as a result of environmental exposure.


Asunto(s)
Predisposición Genética a la Enfermedad/genética , Neoplasias/genética , Polimorfismo de Nucleótido Simple , Proteínas Serina-Treonina Quinasas/genética , 9,10-Dimetil-1,2-benzantraceno , Animales , Western Blotting , Quinasa de Punto de Control 2 , Femenino , Fibroblastos/metabolismo , Eliminación de Gen , Genotipo , Inmunohistoquímica , Masculino , Ratones , Neoplasias/inducido químicamente , Neoplasias/patología , Fosforilación , Factores de Riesgo , Factores Sexuales , Factores de Tiempo , Fosfatasas cdc25/genética , Fosfatasas cdc25/metabolismo
6.
BMJ Surg Interv Health Technol ; 4(1): e000125, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35909993

RESUMEN

Objectives: To assess the feasibility of using electronic health record (EHR) derived clinical data within an active surveillance setting to evaluate the safety of a novel intervertebral body implant (IVBI) stabilization device. Design: Retrospective, longitudinal observational cohort study comparing clinical outcomes for patients seen through 1 year following spinal fusion surgery. Setting: Lahey Health network, which includes academic tertiary hospitals, outpatient clinics, and independent provider offices in the New England region of the USA. Participants: All spine surgery patients aged 18 or older who underwent thoracic or lumbar spinal arthrodesis surgeries were included. Main outcome measures: The clinical outcomes of patients treated with the CONCORDE Bullet (CB) interbody spine system (DePuy) between April 2015 and December 2018 were compared with those patients receiving alternative spine stabilization interbody device implants. The primary endpoint was reoperation rate at 1 year, with secondary endpoints including the requirement for blood transfusion during index hospitalization, 1 year rate of any cause hospitalization, 1 year rate of surgical site infection, and mortality at 1 year. Results: Among the 606 patients undergoing thoracic or lumbar spinal fusion surgery during the study period, 136 received only the CB. In comparison with patients who did not receive the CB, no significant differences were found in the rate of reoperation at 1 year or the rates of secondary safety outcomes. Conclusions: Data derived from the EHR can be successfully leveraged to assess the safety of IVBI devices, in this case demonstrating no significant differences in the rates of risk-adjusted safety endpoints between patients undergoing spinal surgery with the CB as compared with alternative spinal implants.

7.
Mutat Res ; 714(1-2): 1-10, 2011 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-21376736

RESUMEN

The polo-like kinases (Plks1-5) are emerging as an important class of proteins involved in many facets of cell cycle regulation and response to DNA damage and stress. Here we show that Plk3 phosphorylates the key cell cycle protein phosphatase Cdc25A on two serine residues in its cyclinB/cdk1 docking domain and regulates its stability in response to DNA damage. We generated a Plk3 knock-out mouse and show that Cdc25A protein from Plk3-deficient cells is less susceptible to DNA damage-mediated degradation than cells with functional Plk3. We also show that absence of Plk3 correlates with loss of the G1/S cell cycle checkpoint. However, neither this compromised DNA damage checkpoint nor reduced susceptibility to proteasome-mediated degradation after DNA damage translated into a significant increase in tumor incidence in the Plk3-deficient mice.


Asunto(s)
Daño del ADN , Neoplasias/genética , Proteínas Serina-Treonina Quinasas/genética , Fosfatasas cdc25/metabolismo , Animales , Ciclo Celular , Línea Celular , Ratones , Ratones Noqueados , Fosforilación , Ubiquitinación , Fosfatasas cdc25/química
8.
JACC Cardiovasc Interv ; 14(23): 2598-2609, 2021 12 13.
Artículo en Inglés | MEDLINE | ID: mdl-34887051

RESUMEN

OBJECTIVES: This study sought to determine the safety and efficacy of paclitaxel (PTX) devices in the treatment of peripheral artery disease involving the femoropopliteal artery. BACKGROUND: A meta-analysis of PTX devices for the treatment of femoropopliteal artery disease reported a mortality signal. METHODS: This was a multicenter cohort study using an integrated clinical data surveillance system to conduct a prospective, propensity score-matched survival analysis of 2,456 patients in the Society for Vascular Surgery Vascular Quality Initiative from January 2017 to May 2020. The study compared PTX drug-coated balloon angioplasty versus percutaneous transluminal balloon angioplasty, PTX drug-eluting stents versus bare-metal stents, and any PTX device versus any non-PTX device. The primary outcome was 2-year survival. Secondary endpoints were successful ambulation and interventional success. RESULTS: Treatment with any PTX device versus any non-PTX device was associated with increased 2-year survival (89.5% vs 86.7%; HR: 0.79; 95% CI: 0.72-0.87; P = 0.004), improved interventional success (81.6% vs 77.6%; HR: 0.82; 95% CI: 0.74-0.91; P < 0.001), and higher rates of independent ambulation at 1 year (86.0% vs 83.4%; HR: 0.85; 95% CI: 0.79-0.91; P = 0.008). Treatment with PTX drug-coated balloon angioplasty was associated with improved survival at 2 years (88.9% vs 85.7%; HR: 0.77; 95% CI: 0.70-0.86; P = 0.005), while PTX drug-eluting stent therapy was associated with similar survival compared with bare-metal stent therapy (91.3% vs 89.6%; HR: 0.84; 95% CI: 0.70-1.01; P = 0.36). CONCLUSIONS: In this prospective, active surveillance of a national clinical registry, PTX-containing devices were associated with increased survival at 2 years and improved clinical outcomes at 1 year. (VQI DELTA Paclitaxel Device Safety Analysis [VQI-PTX]; NCT04110288).


Asunto(s)
Angioplastia de Balón , Fármacos Cardiovasculares , Stents Liberadores de Fármacos , Enfermedad Arterial Periférica , Estudios de Cohortes , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Humanos , Estudios Multicéntricos como Asunto , Paclitaxel , Enfermedad Arterial Periférica/tratamiento farmacológico , Enfermedad Arterial Periférica/terapia , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Grado de Desobstrucción Vascular
9.
Circ Cardiovasc Qual Outcomes ; 13(4): e006105, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32283971

RESUMEN

BACKGROUND: Several defibrillator leads have been recalled due to early lead failure leading to significant patient harm. Confirming the safety of contemporary defibrillator leads is essential to optimizing treatment for patients receiving implantable cardioverter-defibrillators (ICDs). We therefore sought to assess the comparative long-term safety of the 4 most commonly implanted ICD leads within the National Cardiovascular Data Registry ICD Registry. METHODS AND RESULTS: A propensity-matched survival analysis of the ICD Registry was performed evaluating 4 contemporary ICD leads in patients receiving an ICD system for the first time. All patients in the ICD Registry aged ≥18 years who underwent an implant of an ICD between April 1, 2011 and March 31, 2016 were included. Monitoring of safety began with ICD implant and continued up to 5 years. A meaningful difference in ICD failure rate was defined as twice (or more) the lead failure rate observed in the propensity-matched comparator patients. Among the 374 132 patients who received a new ICD implant, no safety alerts were triggered for the primary safety end point of lead failure for any of the high energy leads studied. Estimated rates of freedom from lead failure at 5 years ranged from 97.7% to 98.9% for the 4 high-energy leads of interest. CONCLUSIONS: Though limited by incomplete long-term outcomes ascertainment, active surveillance of the ICD Registry suggests that there were no meaningful differences in the rate of ICD high-energy lead survival for the 4 most commonly used high-energy ICD leads.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Falla de Prótesis , Anciano , Cardioversión Eléctrica/efectos adversos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Vigilancia de Productos Comercializados , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
10.
BMJ Surg Interv Health Technol ; 2(1): e000047, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-35047794

RESUMEN

OBJECTIVES: The CathPCI Data Extraction and Longitudinal Trend Analysis study was designed to determine the feasibility of conducting prospective surveillance of a large national registry to perform comparative safety analyses of medical devices. We sought to determine whether the complementary use of retrospective case data could improve safety signal detection time. DESIGN: We performed a simulated surveillance study of the comparative safety of the Mynx vascular closure device (VCD) with propensity score matched alternate VCD recipients, using both retrospective and prospective cohort data. SETTING: Centers within the USA using the National Cardiovascular Data Registry (NCDR) CathPCI Registry. PARTICIPANTS: Percutaneous coronary intervention cases captured within the NCDR CathPCI Registry from July 1, 2009 to September 30, 2013 were included in the analysis. INTERVENTIONS: None. MAIN OUTCOME MEASURES: Absolute and relative risk (RR) of any vascular complication (a composite of bleeding at access site, hematoma at access site, retroperitoneal bleeding, and other vascular complications requiring treatment); time to signal detection. RESULTS: A safety alert was detected for the primary outcome of "any vascular complication" after 15 months of surveillance and was sustained for the study duration (absolute risk of any vascular complication, 1.20% vs 0.73%, RR, 1.63; 95% CI 1.50 to 1.79; p<0.001). The safety signal was identified 12 months earlier with the use of retrospective case data than during the initial study. CONCLUSIONS: Prospective, active surveillance of cardiovascular registries is feasible to perform comparative analyses of medical devices. Retrospective data may complement prospective surveillance to improve time to signal detection, indicating the need for earlier prospective application of safety surveillance for devices new to the market.

11.
Circ Cardiovasc Qual Outcomes ; 12(2): e004666, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30764652

RESUMEN

Background Current strategies for ensuring the postmarket safety of medical devices are limited by small sample size and reliance on voluntary reporting of adverse events. Prospective, active surveillance of clinical registries may provide early warnings in the postmarket evaluation of medical device safety but has not been demonstrated in national clinical data registries. Methods and Results The CathPCI DELTA (Data Extraction and Longitudinal Trend Analysis) study was designed to assess the feasibility of prospective, active safety surveillance of medical devices within a national cardiovascular registry. We sought to assess the ability of our surveillance strategy to avoid false safety alerts by conducting an active safety surveillance study of aspiration thrombectomy catheters using data within the National Cardiovascular Data Registry CathPCI registry, where no difference in safety outcomes were anticipated for the primary in-hospital safety outcome of death and major adverse cardiovascular events (MACE). We performed a propensity-matched analysis of 5 aspiration thrombectomy catheter devices used during percutaneous coronary intervention among 95 925 patients presenting with ST-segment-elevation myocardial infarction between January 1, 2011 and September 30, 2013. After 33 months of surveillance, no safety alerts were triggered for the primary safety endpoints of death or MACE, with no between-catheter differences observed. The absolute risk of death during acute hospitalization ranged from 5.11% to 5.32% among the most commonly used aspiration thrombectomy catheter devices, with relative risks for death ranging from 0.96 to 1.03. The absolute risk of MACE ranged from 9.78% to 10.18%, with relative risks for MACE ranging from 0.99 to 1.02. There were no statistically significant differences in the rates of death or MACE between any of the aspiration thrombectomy catheter devices analyzed. Conclusions The CathPCI DELTA study demonstrates that prospective, active safety surveillance of national clinical registries is feasible to provide near-real-time safety assessments of new medical devices.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Intervención Coronaria Percutánea/instrumentación , Vigilancia de Productos Comercializados , Trombectomía/instrumentación , Anciano , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Diseño de Equipo , Falla de Equipo , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Sistema de Registros , Medición de Riesgo , Trombectomía/efectos adversos , Trombectomía/mortalidad , Resultado del Tratamiento
12.
Arch Pediatr Adolesc Med ; 161(1): 17-20, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17199062

RESUMEN

OBJECTIVES: To estimate the prevalence and incidence of overweight among low-income, inner-city children aged 3 to 7 years and to determine predictors of changes in body mass index (BMI) (calculated as weight in kilograms divided by height in meters squared) percentile. DESIGN: Retrospective cohort study using administrative and medical records. SETTING: The Philadelphia Health Care Centers, 1996 through 2003. PARTICIPANTS: Three hundred eighty-six patients who had at least 2 well-child visits between the ages of 3 and 7 years, had at least 1 visit between September 2001 and 2003, and were between the ages of 5 and 7 years at the most recent visit. Mean follow-up time was 2.4 years. MAIN EXPOSURES: Age, sex, race/ethnicity, and BMI percentile at baseline. MAIN OUTCOME MEASURES: Prevalence and incidence of overweight and at risk of overweight and change in BMI percentile. RESULTS: Prevalence of overweight at the initial visit was 18%, with 16% at risk of overweight. At the last visit, the prevalence of overweight was 19%, with 15% at risk of overweight. Based on maximum BMI percentile, 29% were overweight at some point and an additional 19% were at risk of overweight at least once. Annualized incidence of overweight among those not overweight at baseline was 5% per year: 2% per year for normal-weight children and 14% per year for children in the at-risk category. The outcomes were not associated with sex, race/ethnicity, or age at first or last visit. Incident overweight was positively associated with BMI percentile at baseline. CONCLUSION: The early onset and frequent persistence of overweight demonstrated herein underline the need to prevent overweight among very young children.


Asunto(s)
Centros Comunitarios de Salud/estadística & datos numéricos , Obesidad/epidemiología , Sobrepeso , Índice de Masa Corporal , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Philadelphia/epidemiología , Prevalencia , Estudios Retrospectivos , Población Urbana
13.
Mutat Res ; 616(1-2): 201-9, 2007 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-17174984

RESUMEN

Allelic variants of CHEK2 contribute to an elevated risk for human breast cancer and possibly other cancer types. In particular, the CHEK2*1100delC polymorphic variant has been identified as a low-penetrance breast cancer susceptibility allele in breast cancer families with wild type BRCA1 and BRCA2. To better understand the molecular basis by which this allele increases risk for disease, we have generated a mouse in which the wild type CHEK2 (Chk2 in mouse) allele has been replaced with the 1100delC variant. Mouse embryo fibroblasts (MEFs) derived from these mice have an altered cell cycle profile in which a far greater proportion of cells are in S-phase and in G2 (4N) compared with wild type cells. The mutant cells show signs of spontaneous genomic instability as indicated by polyploidy and an increase in DNA double strand breaks.


Asunto(s)
Predisposición Genética a la Enfermedad , Inestabilidad Genómica , Neoplasias Mamarias Experimentales/genética , Proteínas Serina-Treonina Quinasas/genética , Alelos , Animales , Ciclo Celular , Células Cultivadas , Quinasa de Punto de Control 2 , Daño del ADN , Femenino , Homocigoto , Ratones , Ratones Transgénicos , Polimorfismo Genético , Proteínas Serina-Treonina Quinasas/metabolismo , Estabilidad del ARN , ARN Mensajero/metabolismo
14.
Environ Mol Mutagen ; 47(5): 334-44, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16649189

RESUMEN

Exposure to inorganic arsenic in drinking water is linked to cancer in humans, but the mechanism of arsenic-induced cancer is not clear. Arsenic is not a powerful point mutagen, but can cause chromosome malsegregation and mitotic recombination, two events that can cause loss of tumor suppressor alleles and thereby contribute to the evolution of cancerous cells. To determine whether arsenic increases the frequency of allele loss due to either malsegregation or mitotic recombination in vivo, Aprt(+/-) hybrid mice were exposed to sodium arsenite (10 mg/L) in their drinking water for 10 weeks. To determine whether arsenic enhances the action of a known mutagen, half of the arsenic-treated mice were exposed to benzo[a]pyrene (BaP) for 8 weeks by skin painting (500 nmoles/week). Cells were taken from painted dorsal skin and cultured in the presence of 2,6-diaminopurine (DAP), to select colonies lacking adenosine phosphoribosyl transferase (Aprt) activity. The frequency of DAP-resistant (DAP(r)) colonies varied substantially within the treatment groups, but there was no significant difference between the groups. Analysis of DNA from DAP(r) colonies suggested that mitotic recombination contributed to the loss of wild-type Aprt allele. Whether arsenic or BaP enhanced or diminished the frequency of this process could not be deduced from these data.


Asunto(s)
Adenina Fosforribosiltransferasa/metabolismo , Arsénico/toxicidad , Benzo(a)pireno/toxicidad , Pérdida de Heterocigocidad/efectos de los fármacos , 2-Aminopurina/análogos & derivados , 2-Aminopurina/farmacología , Adenina Fosforribosiltransferasa/genética , Animales , Células Cultivadas , Femenino , Masculino , Ratones , Ratones Transgénicos , Mutágenos/toxicidad , Piel/efectos de los fármacos , Piel/metabolismo
15.
Mutat Res ; 588(1): 35-46, 2005 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-16242380

RESUMEN

Exposure to inorganic arsenic in drinking water is linked to skin, lung and bladder cancer in humans. The mechanism of arsenic-induced cancer is not clear, but exposure to arsenic and polycyclic arylhydrocarbons (PAH) is more carcinogenic than exposure to either type of carcinogen alone. Arsenic can also generate reactive oxygen species, suggesting that oxidation of DNA may play a role in carcinogenesis. Oxidization of guanosines in polyG tracts is known to cause frameshift mutations, and such events can be detected in situ using the G11 placental alkaline phosphatase (PLAP) transgenic mouse model, which reports frameshift mutations in a run of 11 G:C basepairs by generating cells containing heat-resistant alkaline phosphatase activity. PAH can also induce frameshift mutations. In the study described here, FVB/N mice carrying the G11 PLAP transgene were crossed to C57Bl/6 mice. Half of the hybrid mice were given drinking water with sodium arsenite (10 mg/L) for 10 weeks. Half of the arsenic treated mice were also exposed to benzo[a]pyrene (BaP) by skin painting (500 nmol/week) for 8 weeks. Another group of mice was exposed to BaP but not arsenic. The effect on frameshift mutation was assessed by staining sections of skin tissue to detect cells with PLAP activity. Arsenic alone had no significant effect. On average, mice given BaP alone had approximately three times more PLAP-positive (PLAP+) cells. By contrast, mice exposed to both arsenic and BaP exhibited 10-fold more PLAP+ cells in the skin, and these cells were often arranged in large clusters, suggesting derivation from stem cells. Whereas combined treatment produced more PLAP+ cells, stable BaP adduct levels and arsenic burdens were not higher in mice exposed to both agents compared to mice exposed to either one agent or the other.


Asunto(s)
Arsénico , Arsenitos/toxicidad , Benzo(a)pireno/toxicidad , Mutágenos/toxicidad , Piel/metabolismo , Compuestos de Sodio/toxicidad , Fosfatasa Alcalina/metabolismo , Animales , Aductos de ADN , Sinergismo Farmacológico , Ratones , Ratones Endogámicos C57BL , Ratones Transgénicos , Piel/efectos de los fármacos , Piel/patología
16.
Circ Cardiovasc Qual Outcomes ; 8(1): 38-46, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25491915

RESUMEN

BACKGROUND: Current approaches for postmarket medical device safety surveillance are limited in their ability to produce timely and accurate assessments of adverse event rates. METHODS AND RESULTS: The Data Extraction and Longitudinal Trend Analysis (DELTA) network study was a multicenter prospective observational study designed to evaluate the safety of devices used during percutaneous coronary interventions. All adult patients undergoing percutaneous coronary intervention from January 2008 to December 2012 at 5 participating Massachusetts sites were included. A safety alert was triggered if the cumulative observed adverse event rates for the study device exceeded the upper 95% confidence interval of the event rates of propensity-matched control cohort. Prespecified sensitivity analyses were developed to validate any identified safety signal. A total of 23,805 consecutive percutaneous coronary intervention procedures were evaluated. Two of 24 safety analyses triggered safety alerts. Patients receiving Perclose vascular closure device experienced an increased risk of minor vascular complications (relative risk, 4.14; P<0.01) and any vascular complication (relative risk, 2.06; P=0.01) when compared with propensity-matched patients receiving alternative vascular closure device, a result primarily driven by relatively high event rates at 1 participating center. Sensitivity analyses based on alternative risk adjustment methods confirmed a pattern of increased rate of complications at 1 of the 5 participating sites in their use of Perclose vascular closure device. CONCLUSIONS: The DELTA network study demonstrates that distributed automated prospective safety surveillance has the potential of providing near real-time assessment of safety risks of newly approved medical devices.


Asunto(s)
Seguridad del Paciente , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/tendencias , Vigilancia de Productos Comercializados/tendencias , Dispositivos de Cierre Vascular/tendencias , Stents Liberadores de Fármacos/efectos adversos , Stents Liberadores de Fármacos/tendencias , Dispositivos de Protección Embólica/efectos adversos , Dispositivos de Protección Embólica/tendencias , Diseño de Equipo , Seguridad de Equipos , Humanos , Modelos Logísticos , Estudios Longitudinales , Massachusetts , Análisis Multivariante , Intervención Coronaria Percutánea/efectos adversos , Puntaje de Propensión , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Dispositivos de Cierre Vascular/efectos adversos
17.
Fam Med ; 35(8): 585-90, 2003 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12947522

RESUMEN

BACKGROUND AND OBJECTIVES: The association between functional illiteracy and poor health has led to pediatric literacy promotion programs in the primary care setting. These interventions do not address linked parental literacy needs. An obstacle to referring adults to literacy services is the lack of an instrument that can efficiently identify individuals who could benefit from such programs. We sought to identify screening items sufficiently simple to use in clinical practice. METHODS: This cross-sectional study examined 98 adult primary caregivers of preschool children seen in an inner-city primary care setting. Literacy level and 17 variables predicted to be associated with low literacy were assessed. RESULTS: Three items were independently associated with a 6th grade reading level: (1) less than 12th grade completion, (2) not living with the child's other parent, and (3) not reading for pleasure. Receiver operating characteristic (ROC) curve analysis indicates that, used together, these variables have discriminant capacity, with an area under the ROC curve of.76. CONCLUSIONS: Three items for use in a simple screening instrument for parental low literacy were identified. Used together, they had favorable characteristics but must be further tested for generalizability.


Asunto(s)
Cuidadores/estadística & datos numéricos , Cuidado del Niño/estadística & datos numéricos , Escolaridad , Adulto , Distribución de Chi-Cuadrado , Cuidado del Niño/normas , Preescolar , Intervalos de Confianza , Estudios Transversales , Humanos , Análisis Multivariante , Oportunidad Relativa , Atención Primaria de Salud , Sensibilidad y Especificidad , Encuestas y Cuestionarios , Estados Unidos
18.
Clin Pediatr (Phila) ; 53(7): 666-71, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24634432

RESUMEN

OBJECTIVES: To examine the prevalence and correlates of overweight and obesity among patients aged 0 to 2 years, and to compare 3 measures of early childhood weight status, weight-for-age, weight-for-length, and body mass index-for-age. SETTING: Well-child visits in the Philadelphia Health Centers, public community health centers providing primary health care to predominantly low-income residents. STUDY DESIGN: Cross-sectional. RESULTS: Using the 3 measures, 13% to 16% of boys and 10% to 13% of girls seen during 2010 were classified as high in weight. No consistent associations with feeding method were identified. "Other/unknown" race was consistently associated with higher rates of overweight than the African American reference group. Hispanic girls had higher rates of high weight-for-age and weight-for-length than African American girls. CONCLUSION: Elevated weight status emerges in a significant proportion of very young children, by all of the commonly used weight measures. There is an urgent need for appropriate clinical strategies to prevent and respond to overweight in this age group.


Asunto(s)
Obesidad/epidemiología , Sobrepeso/epidemiología , Áreas de Pobreza , Factores de Edad , Estatura , Índice de Masa Corporal , Femenino , Humanos , Lactante , Masculino , Philadelphia/epidemiología , Prevalencia , Atención Primaria de Salud , Población Urbana
19.
J Prim Care Community Health ; 5(2): 152-5, 2014 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-24327594

RESUMEN

BACKGROUND: Child obesity is a major health problem particularly affecting disadvantaged population groups. Severe obesity carries additional health risks for children. In the context of the childhood obesity epidemic, high blood pressure among children is of increasing concern. METHODS: Chart reviews were carried out to examine the prevalence of severe obesity and its association with high blood pressure measurements among randomly selected patients aged 3 to 17 years who had well-child care visits at 8 public community health centers during 2010. RESULTS: A majority of the 691 patients reviewed were African American (58%); an additional 16% were Hispanic. The prevalence of severe obesity was 7.7% (95% confidence interval = 5.8% to 9.9%) and the prevalence of high blood pressure measurements was 17.5% (95% confidence interval = 14.8% to 20.6%). Patients who were severely obese were more than twice as likely as other children to have high blood pressure values. CONCLUSIONS: Severe obesity is associated with substantially increased frequency of high blood pressure measurements in children, and should be investigated further as a potential marker for hypertension in children. Primary care providers should be prepared to diagnose and treat hypertension in severely obese children.


Asunto(s)
Hipertensión/epidemiología , Obesidad/epidemiología , Adolescente , Análisis de Varianza , Niño , Preescolar , Femenino , Humanos , Hipertensión/etiología , Masculino , Obesidad/complicaciones , Philadelphia/epidemiología , Prevalencia
20.
J Am Heart Assoc ; 2(3): e000174, 2013 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-23709565

RESUMEN

BACKGROUND: Access site complications contribute to morbidity and mortality during percutaneous coronary intervention (PCI). Transradial arterial access significantly lowers the risk of access site complications compared to transfemoral arteriotomy. We sought to develop a prediction model for access site complications in patients undergoing PCI with femoral arteriotomy, and assess whether transradial access was selectively used in patients at high risk for complications. METHODS AND RESULTS: We analyzed 17 509 patients who underwent PCI without circulatory support from 2008 to 2011 at 5 institutions. Transradial arterial access was used in 17.8% of patients. In those who underwent transfemoral access, 177 (1.2%) patients had access site complications. Using preprocedural clinical and demographic data, a prediction model for femoral arteriotomy complications was generated. The variables retained in the model included: elevated age (P<0.001), female gender (P<0.001), elevated troponin (P<0.001), decreased renal function or dialysis (P=0.002), emergent PCI (P=0.01), prior PCI (P=0.005), diabetes (P=0.008), and peripheral artery disease (P=0.003). The model showed moderate discrimination (optimism-adjusted c-statistic=0.72) and was internally validated via bootstrap resampling. Patients with higher predicted risk of complications via transfemoral access were less likely to receive transradial access (P<0.001). Similar results were seen in patients presenting with and without ST-segment myocardial infarction and when adjusting for individual physician operator. CONCLUSIONS: We generated and validated a model for transfemoral access site complications during PCI. Paradoxically, patients most likely to develop access site complications from transfemoral access, and therefore benefit from transradial access, were the least likely to receive transradial access.


Asunto(s)
Intervención Coronaria Percutánea/métodos , Arteria Radial , Anciano , Femenino , Arteria Femoral , Humanos , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Pronóstico , Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA