Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Environ Sci Technol ; 58(25): 11084-11095, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38860676

RESUMEN

Ethylene oxide ("EtO") is an industrially made volatile organic compound and a known human carcinogen. There are few reliable reports of ambient EtO concentrations around production and end-use facilities, however, despite major exposure concerns. We present in situ, fast (1 Hz), sensitive EtO measurements made during February 2023 across the southeastern Louisiana industrial corridor. We aggregated mobile data at 500 m spatial resolution and reported average mixing ratios for 75 km of the corridor. Mean and median aggregated values were 31.4 and 23.3 ppt, respectively, and a majority (75%) of 500 m grid cells were above 10.9 ppt, the lifetime exposure concentration corresponding to 100-in-one million excess cancer risk (1 × 10-4). A small subset (3.3%) were above 109 ppt (1000-in-one million cancer risk, 1 × 10-3); these tended to be near EtO-emitting facilities, though we observed plumes over 10 km from the nearest facilities. Many plumes were highly correlated with other measured gases, indicating potential emission sources, and a subset was measured simultaneously with a second commercial analyzer, showing good agreement. We estimated EtO for 13 census tracts, all of which were higher than EPA estimates (median difference of 21.3 ppt). Our findings provide important information about EtO concentrations and potential exposure risks in a key industrial region and advance the application of EtO analytical methods for ambient sampling and mobile monitoring for air toxics.


Asunto(s)
Monitoreo del Ambiente , Óxido de Etileno , Louisiana , Monitoreo del Ambiente/métodos , Humanos , Contaminantes Atmosféricos/análisis
2.
Nicotine Tob Res ; 25(1): 164-169, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36041039

RESUMEN

INTRODUCTION: In July 2018, the U.S. Department of Housing and Urban Development passed a rule requiring public housing authorities to implement smoke-free housing (SFH) policies. We measured secondhand smoke (SHS) exposure immediately before, and repeatedly up to 36 months post-SFH policy implementation in a purposeful sample of 21 New York City (NYC) high-rise buildings (>15 floors): 10 NYC Housing Authority (NYCHA) buildings subject to the policy and 11 privately managed buildings in which most residents received housing vouchers (herein "Section 8"). AIMS AND METHODS: We invited participants from nonsmoking households (NYCHA n = 157, Section-8 n = 118) to enroll in a longitudinal air monitoring study, measuring (1) nicotine concentration with passive, bisulfate-coated filters, and (2) particulate matter (PM2.5) with low-cost particle sensors. We also measured nicotine concentrations and counted cigarette butts in common areas (n = 91 stairwells and hallways). We repeated air monitoring sessions in households and common areas every 6 months, totaling six post-policy sessions. RESULTS: After 3 years, we observed larger declines in nicotine concentration in NYCHA hallways than in Section-8, [difference-in-difference (DID) = -1.92 µg/m3 (95% CI -2.98, -0.87), p = .001]. In stairwells, nicotine concentration declines were larger in NYCHA buildings, but the differences were not statistically significant [DID= -1.10 µg/m3 (95% CI -2.40, 0.18), p = .089]. In households, there was no differential change in nicotine concentration (p = .093) or in PM2.5 levels (p = .385). CONCLUSIONS: Nicotine concentration reductions in NYCHA common areas over 3 years may be attributable to the SFH policy, reflecting its gradual implementation over this time. IMPLICATIONS: Continued air monitoring over multiple years has demonstrated that SHS exposure may be declining more rapidly in NYCHA common areas as a result of SFH policy adherence. This may have positive implications for improved health outcomes among those living in public housing, but additional tracking of air quality and studies of health outcomes are needed. Ongoing efforts by NYCHA to integrate the SFH policy into wider healthier-homes initiatives may increase policy compliance.


Asunto(s)
Contaminación del Aire Interior , Política para Fumadores , Contaminación por Humo de Tabaco , Humanos , Vivienda Popular , Vivienda , Contaminación por Humo de Tabaco/análisis , Ciudad de Nueva York , Nicotina/análisis , Material Particulado/análisis , Contaminación del Aire Interior/análisis
3.
J Asthma ; 60(3): 625-634, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-35657971

RESUMEN

OBJECTIVE: To determine if the addition of home environmental control strategies (ECSs) to controller medication titration reduces asthma controller medication requirements and in-home allergen concentrations among children with persistent asthma in Baltimore City. METHODS: 155 children ages 5-17 with allergen-sensitized asthma were enrolled in a 6-month randomized clinical trial of multifaceted, individually-tailored ECS plus asthma controller medication titration compared to controller medication titration alone. Participants had to meet criteria for persistent asthma and have had an exacerbation in the previous 18 months. Allergen sensitization (mouse, cockroach, cat, dog, dust mite) was assessed at baseline and home dust allergen concentrations were measured at baseline, 3 and 6 months. ECS was delivered 3-4 times over the trial. Asthma controller medication was titrated using a guidelines-based algorithm at baseline, 2, 4, and 6 months. The primary outcome was controller medication treatment step at 6 months (0-6, as-needed albuterol to high-dose ICS + LABA). RESULTS: The population was predominately Black (90%), on public insurance (93%), and male (61%). The mean age was 10.1 years (SD 3.3). More than 70% were sensitized to a rodent, >50% to cockroach, and 70% were polysensitized. At 6 months, there were no differences in either treatment step (3.8 [SD 1.4] vs. 3.7 [SD 1.5]) or allergen concentrations between groups. CONCLUSION: Among this predominantly low-income, Black pediatric asthma population, the addition of ECS to controller medication titration reduced neither indoor allergen concentrations nor controller medication requirements compared to controller medication titration alone.


Asunto(s)
Asma , Cucarachas , Humanos , Masculino , Animales , Ratones , Perros , Asma/tratamiento farmacológico , Asma/epidemiología , Baltimore , Exposición a Riesgos Ambientales/prevención & control , Población Urbana , Alérgenos
4.
Environ Res ; 221: 115234, 2023 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-36634896

RESUMEN

INTRODUCTION: The use of electronic nicotine delivery systems (ENDS), or vaping, is a relatively recent phenomenon, and there are various gaps in our current knowledge regarding the specific effects of e-cigarettes, such as their immunological effects. The importance of this question became even more relevant in light of the COVID-19 pandemic. OBJECTIVE: This literature review examines the relationship between the use of electronic nicotine delivery systems (ENDS) and immunological effects to examine available information and identify gaps in the current knowledge. Our search strategy included studies focusing on the effects of ENDS on the immune response during infectious respiratory diseases such as COVID-19 and pneumonia. METHODS: Peer-reviewed studies presenting quantitative data published from 2007, the year that e-cigarettes were introduced to the US market until 2022 have been included. All studies were indexed in PubMed. We excluded papers on THC and EVALI (E-cigarette, or Vaping Product, Use Associated Lung Injury) as we wanted to focus on the effects of nicotine devices. RESULTS: Among the 21 articles that assessed the relationship between ENDS and immunological health effects, we found eight studies based on cell models, two articles based on both cell and mouse models, five articles based on mouse models, and six studies of human populations. Most of the articles identified in our review demonstrated a potential association between vaping and adverse immunological health effects. DISCUSSION: Overall, the evidence from the cell and animal studies indicates that there is a positive, statistically significant association between vaping and adverse immune response during infectious respiratory diseases. The evidence from human studies is not conclusive.


Asunto(s)
COVID-19 , Sistemas Electrónicos de Liberación de Nicotina , Vapeo , Animales , Ratones , Humanos , Pandemias , Pulmón , Nicotina , Vapeo/efectos adversos
5.
Environ Res ; 231(Pt 1): 116032, 2023 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-37137457

RESUMEN

BACKGROUND: Few studies have evaluated Electronic Nicotine Delivery Systems (ENDS) in longitudinal studies, as a potential source of metals which may have carcinogenic, neurotoxic, and cardiotoxic effects. We evaluated metal body burden by ENDS use status in a longitudinal population-based national survey. METHODS: We used the Population Assessment of Tobacco and Health (PATH) Study wave 1 (2013-2014), wave 2 (2014-2015), and wave 3 (2015-2016) adult data to assess urinary concentrations of seven metals among (1) ENDS only users who never used any nonelectronic tobacco products (n = 50), (2) ENDS only users who were former users of any nonelectronic tobacco products (n = 123) and (3) Never users (n = 1501) of any tobacco product. RESULTS: Among ENDS only users who never used any nonelectronic tobacco products (n = 50), the geometric mean ratios (GMRs) of Cd and Pb were 1.25 (95%CI: 1.09-1.42) and 1.19 (95%CI: 1.05-1.34), respectively, compared to never users after adjustment for PATH Study wave, age, sex, race/ethnicity, education, region, secondhand smoke at home and work, and cannabis and other substance use. After the same adjustment, the corresponding GMRs were 1.48 (95%CI: 1.32-1.67) and 1.43 (95%CI: 1.28-1.60) for ENDS only users who were former users of any nonelectronic tobacco products (n = 123). No difference was observed in urinary concentrations of other metals comparing ENDS users to never users of any tobacco product. DISCUSSION: ENDS users show higher urinary levels of Cd and Pb, including lifetime exclusive ENDS users compared to never users of any tobacco product. These findings are limited by the small sample size and could be related to underreporting of past combustible tobacco use or other factors. Metals typical of ENDS such as nickel and chromium unfortunately are not available in PATH. Studies assessing metal exposure associated with long term lifetime exclusive ENDS use (≥5 years) with larger sample size are needed.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Productos de Tabaco , Cadmio , Plomo , Estudios Longitudinales , Carcinógenos
6.
Atmos Environ (1994) ; 3102023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37901719

RESUMEN

Low-cost air quality monitors are growing in popularity among both researchers and community members to understand variability in pollutant concentrations. Several studies have produced calibration approaches for these sensors for ambient air. These calibrations have been shown to depend primarily on relative humidity, particle size distribution, and particle composition, which may be different in indoor environments. However, despite the fact that most people spend the majority of their time indoors, little is known about the accuracy of commonly used devices indoors. This stems from the fact that calibration data for sensors operating in indoor environments are rare. In this study, we sought to evaluate the accuracy of the raw data from PurpleAir fine particulate matter monitors and for published calibration approaches that vary in complexity, ranging from simply applying linear corrections to those requiring co-locating a filter sample for correction with a gravimetric concentration during a baseline visit. Our data includes PurpleAir devices that were co-located in each home with a gravimetric sample for 1-week periods (265 samples from 151 homes). Weekly-averaged gravimetric concentrations ranged between the limit of detection (3 µg/m3) and 330 µg/m3. We found a strong correlation between the PurpleAir monitor and the gravimetric concentration (R>0.91) using internal calibrations provided by the manufacturer. However, the PurpleAir data substantially overestimated indoor concentrations compared to the gravimetric concentration (mean bias error ≥ 23.6 µg/m3 using internal calibrations provided by the manufacturer). Calibrations based on ambient air data maintained high correlations (R ≥ 0.92) and substantially reduced bias (e.g. mean bias error = 10.1 µg/m3 using a US-wide calibration approach). Using a gravimetric sample from a baseline visit to calibrate data for later visits led to an improvement over the internal calibrations, but performed worse than the simpler calibration approaches based on ambient air pollution data. Furthermore, calibrations based on ambient air pollution data performed best when weekly-averaged concentrations did not exceed 30 µg/m3, likely because the majority of the data used to train these models were below this concentration.

7.
Am J Respir Crit Care Med ; 205(4): 421-430, 2022 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-34449285

RESUMEN

Rationale: Indoor particulate matter is associated with worse chronic obstructive pulmonary disease (COPD) outcomes. It remains unknown whether reductions of indoor pollutants improve respiratory morbidity. Objectives: To determine whether placement of active portable high-efficiency particulate air cleaners can improve respiratory morbidity in former smokers. Methods: Eligible former smokers with moderate-to-severe COPD received active or sham portable high-efficiency particulate absolute air cleaners and were followed for 6 months in this blinded randomized controlled trial. The primary outcome was 6-month change in St. George's Respiratory Questionnaire (SGRQ). Secondary outcomes were exacerbation risk, respiratory symptoms, rescue medication use, and 6-minute-walk distance (6MWD). Intention-to-treat analysis included all subjects, and per-protocol analysis included adherent participants (greater than 80% use of air cleaner). Measurements and Main Results: A total of 116 participants were randomized, of which 84.5% completed the study. There was no statistically significant difference in total SGRQ score, but the active filter group had greater reduction in SGRQ symptom subscale (ß, -7.7 [95% confidence interval (CI), -15.0 to -0.37]) and respiratory symptoms (Breathlessness, Cough, and Sputum Scale, ß, -0.8 [95% CI, -1.5 to -0.1]); and lower rate of moderate exacerbations (incidence rate ratio, 0.32 [95% CI, 0.12-0.91]) and rescue medication use (incidence rate ratio, 0.54 [95% CI, 0.33-0.86]) compared with sham group (all P < 0.05). In per-protocol analysis, there was a statistically significant difference in primary outcome between the active filter versus sham group (SGRQ, ß -4.76 [95% CI, -9.2 to -0.34]) and in moderate exacerbation risk, Breathlessness, Cough, and Sputum Scale, and 6MWD. Participants spending more time indoors were more likely to have treatment benefit. Conclusions: This is the first environmental intervention study conducted among former smokers with COPD showing potential health benefits of portable high-efficiency particulate absolute air cleaners, particularly among those with greater adherence and spending a greater time indoors.


Asunto(s)
Filtros de Aire , Contaminación del Aire Interior/prevención & control , Enfermedad Pulmonar Obstructiva Crónica/rehabilitación , Adulto , Anciano , Anciano de 80 o más Años , Progresión de la Enfermedad , Método Doble Ciego , Femenino , Humanos , Análisis de Intención de Tratar , Masculino , Persona de Mediana Edad , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Resultado del Tratamiento , Prueba de Paso
8.
J Occup Environ Hyg ; 20(11): 536-544, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37578775

RESUMEN

Welding fume is a common exposure in occupational settings. Gravimetric analysis for total particulate matter is common; however, the cost of laboratory analyses limits the availability of quantitative exposure assessment for welding fume metal constituents in occupational settings. We investigated whether a field portable X-ray fluorescence spectrometer (FP-XRF) could provide accurate estimates of personal exposures to metals common in welding fume (chromium, copper, manganese, nickel, vanadium, and zinc). The FP-XRF requires less training and is easier to deploy in many settings than traditional wet laboratory analyses. Filters were analyzed both by FP-XRF and inductively coupled plasma mass spectrometry (ICP-MS). We estimated the FP-XRF limit of detection for each metal and developed a correction factor accounting for the non-uniform deposition pattern on filter samples collected with an Institute of Medicine (IOM) inhalable particulate matter sampler. Strong linear correlation was observed for all metals (0.72

Asunto(s)
Contaminantes Ocupacionales del Aire , Exposición Profesional , Soldadura , Exposición Profesional/análisis , Contaminantes Ocupacionales del Aire/análisis , Acero Inoxidable/análisis , Cobre/análisis , Manganeso/análisis , Níquel/análisis , Rayos X , Vanadio/análisis , Monitoreo del Ambiente/métodos , Cromo/análisis , Zinc/análisis , Espectrometría por Rayos X/métodos , Gases/análisis , Espectrometría de Masas/métodos , Material Particulado/análisis
9.
Environ Res ; 209: 112878, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35131327

RESUMEN

INTRODUCTION: This study investigates the impact of changes in local industry, urban development, and proximity to suspected emission sources on airborne metal concentration in Baltimore, Maryland between 2001 and 2019 with particular focus on the urban industrial community of Curtis Bay in South Baltimore. METHODS: Integrated PM2.5 and PM10 Harvard Impactors were set up at six locations in the Baltimore City metropolitan area in weeklong sampling sessions from January-July 2019 to assess variation in airborne metal concentration by proximity to suspected metal emission sources. PM2.5 and PM10 were collected on Teflo filters and analyzed for a panel of 12 metals and metalloids (As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, and Zn) using inductively coupled plasma mass spectrometry. The findings were compared against airborne metal concentrations reported by the Baltimore Supersite in 2001 and 2003 to assess changes over the 18-year period. RESULTS: PM2.5 concentrations reported from this study ranged from 3.27 µg/m3 to 36.0 µg/m3 and PM10 concentrations ranged from 9.00 µg/m3 to 30.1 µg/m3 across all sampling sites. Metal concentrations ranged from 1.4 times (Cd) to 4.8 times (Cr) higher in PM10 compared to PM2.5. Compared to the study reference site, median PM2.5 concentrations of Co and Fe were roughly 1.8 times and 2.1 times higher, respectively, at near-road sampling sites indicating significant variability in airborne metal concentration by proximity to local traffic emissions. PM2.5 and PM10 Sb concentrations were 3.4 times and 6.7 times higher at a near incinerator site compared to the reference, consistent with existing evidence of Sb sourcing from municipal incinerators in Baltimore City. Decreases in Cr (-40%), Ni (-73%), Pb (-55%), and Zn (-36%) concentrations were observed over the 18-year period while concentrations of Cu, Fe, and Mn were not statistically significantly different. CONCLUSION: Declines in airborne Cr, Ni, Pb, and Zn concentration since 2001 appear to coincide with industrial decline highlighting the success of remediation and redevelopment efforts. Remaining spatial variability is related to vehicular traffic and proximity to a municipal incinerator which should be focal areas for future intervention to reduce metal exposure disparities in Baltimore City.


Asunto(s)
Contaminantes Atmosféricos , Metales Pesados , Contaminantes Atmosféricos/análisis , Baltimore , Monitoreo del Ambiente/métodos , Industrias , Metales Pesados/análisis , Material Particulado/análisis
10.
Environ Res ; 212(Pt A): 113240, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35390303

RESUMEN

The COVID-19 pandemic has resulted in an extraordinary incidence of morbidity and mortality, with almost 6 million deaths worldwide at the time of this writing (https://covid19.who.int/). There has been a pressing need for research that would shed light on factors - especially modifiable factors - that could reduce risks to human health. At least several hundred studies addressing the complex relationships among transmission of SARS-CoV-2, air pollution, and human health have been published. However, these investigations are limited by available and consistent data. The project goal was to seek input into opportunities to improve and fund exposure research on the confluence of air pollution and infectious agents such as SARS-CoV-2. Thirty-two scientists with expertise in exposure science, epidemiology, risk assessment, infectious diseases, and/or air pollution responded to the outreach for information. Most of the respondents expressed value in developing a set of common definitions regarding the extent and type of public health lockdown. Traffic and smoking ranked high as important sources of air pollution warranting source-specific research (in contrast with assessing overall ambient level exposures). Numerous important socioeconomic factors were also identified. Participants offered a wide array of inputs on what they considered to be essential studies to improve our understanding of exposures. These ranged from detailed mechanistic studies to improved air quality monitoring studies and prospective cohort studies. Overall, many respondents indicated that these issues require more research and better study design. As an exercise to solicit opinions, important concepts were brought forth that provide opportunities for scientific collaboration and for consideration for funding prioritization. Further conversations on these concepts are needed to advance our thinking on how to design research that moves us past the documented limitations in the current body of research and prepares us for the next pandemic.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire , COVID-19 , Contaminantes Atmosféricos/análisis , Contaminantes Atmosféricos/toxicidad , Contaminación del Aire/análisis , COVID-19/epidemiología , Control de Enfermedades Transmisibles , Exposición a Riesgos Ambientales/análisis , Humanos , Pandemias , Material Particulado , Estudios Prospectivos , SARS-CoV-2
11.
Environ Res ; 204(Pt C): 112270, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34717948

RESUMEN

Vaping is the action of inhaling and exhaling aerosols from electronic cigarettes. The aerosols contain various amounts of toxic chemicals, including metals. The purpose of this study was to evaluate factors that can influence metal levels, including flavor and nicotine content in the e-liquid, and puff duration. Aerosols were collected from both closed-system (cartridge-based) and open-system e-cigarettes using e-liquids with different flavors (fruit, tobacco, and menthol), nicotine content (0, 6, 24, and 59 mg/mL), and different puff durations (1, 2, and 4 s). The concentrations of 14 metals in the collected aerosols were measured using inductively coupled plasma mass spectroscopy. Aerosol concentrations of As, Fe, and Mn varied significantly among fruit, tobacco, and menthol flavors in both closed-system and open-system devices. Concentrations of Al, Fe, Sn, and U were significantly higher in tobacco or menthol flavored aerosols compared to fruit flavors in closed-system devices. Aerosol W levels were significantly higher in tobacco flavored aerosols compared to fruit flavors in open-system devices. Concentrations of As, Fe, and Mn were higher in tobacco flavored aerosols compared to menthol flavors in both types of devices. The median Pb concentration decreased significantly from 15.8 to 0.88 µg/kg when nicotine content increased from 0 to 59 mg/mL, and median Ni concentration was 9.60 times higher in aerosols with nicotine of 59 mg/mL compared to 24 mg/mL (11.9 vs. 1.24 µg/kg) for closed-system devices. No significant differences were observed in aerosol metal concentrations for different puff durations. Aerosol metal concentrations varied widely between different flavors and nicotine content but not by puff duration. Flavor and nicotine content of the e-liquid could be potential factors in metal emissions. Some elements showed higher concentrations under certain conditions, highlighting the urgent need of developing strict product regulations, especially on e-liquid composition and nicotine content to inform e-cigarette users about metal exposure through vaping.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Productos de Tabaco , Vapeo , Aerosoles , Aromatizantes , Nicotina
12.
Environ Res ; 214(Pt 4): 114125, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35987373

RESUMEN

Salon workers, especially those serving an ethnically and racially diverse clientele (i.e., Black/Latina), may experience disparately high levels of workplace exposures to respiratory irritants, including volatile organic compounds (VOCs). Salon workers are also reported to have a greater risk of developing respiratory conditions compared to the general population. Emerging evidence suggests that occupational chemical exposures may alter the human microbiome and that these alterations may be an important mechanism by which workplace VOC exposures adversely impact respiratory health. This preliminary research investigated the potential effects of 28 VOC urinary biomarkers on the 16S rRNA nasal microbiome in 40 workers from salons primarily serving women of color (Black and Dominican salons) compared to office workers. Our exploratory analysis revealed significant differences in microbial composition by worker group; namely dissimilar levels of Staphylococcus species (S. epidermidis and S. aureus, specifically) in salon workers compared to office workers, and higher alpha diversity levels in workers in Dominican salons compared to workers in Black salons. Within-sample alpha diversity levels tended to be decreased with higher VOC urinary biomarker concentrations, significantly for carbon disulfide, acrolein, acrylonitrile, crotonaldehyde, and vinyl chloride biomarkers. Our research highlights that occupational exposures, particularly to chemicals like VOCs, can impact the respiratory microbiome in the vulnerable salon worker group. Further understanding of the potential effects of chemical mixtures on microbial composition may provide key insights to respiratory health and other adverse health outcomes, as well as direct prevention efforts in this largely historically understudied occupational population.


Asunto(s)
Microbiota , Exposición Profesional , Compuestos Orgánicos Volátiles , Biomarcadores , Femenino , Humanos , Exposición Profesional/efectos adversos , Exposición Profesional/análisis , ARN Ribosómico 16S , Pigmentación de la Piel , Staphylococcus aureus , Compuestos Orgánicos Volátiles/análisis , Compuestos Orgánicos Volátiles/toxicidad
13.
Inhal Toxicol ; 34(3-4): 90-98, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35275758

RESUMEN

While some in vitro and in vivo experiments have studied the toxic effects of e-cigarette (e-cig) components, the typical aerosol properties released from e-cigarettes have not been well characterized. In the present study, we characterized the variability in mass concentration and particle size distribution associated with the aerosol generation of different devices and e-liquid compositions in an experimental setup. The findings of this study indicate a large inter-day variability in the experiments, likely due to poor quality control in some e-cig devices, pointing to the need for a better understanding of all the factors affecting exposures in in vitro and in vivo experiments, and the development of standardized protocols for generation and measurement of e-cig aerosols.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Aerosoles
14.
Bull Environ Contam Toxicol ; 109(6): 1175-1182, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36070093

RESUMEN

This study provides evidence of the seasonal and spatial variation of metal(lloid)s in particulate matter minor to 2.5 microns (PM2.5) in the Toluca Valley Metropolitan Area (TVMA), the fifth largest urban center in Mexico. Four sites were sampled between 2013 and 2014, which included urban and industrial areas, in the dry-cold (November-February) and dry-hot (March-May) seasons; PM2.5 was collected using high- and medium-volume samplers. Metal(lloid) concentrations in PM2.5 were analyzed using inductively coupled plasma‒mass spectrometry (ICP‒MS). The highest 24-hour PM2.5 concentration in the northern area was observed, and the PM2.5 concentrations were independent of the season. Five metal(lloid)s with a recovery percentage above 80% were considered to be reported (Co, Cr, Cu, Mn, and Sb). The maximum concentrations of metal(lloid)s were observed during the dry-cold season, and concentrations were up to one hundred or thousand fold with respect to the dry-hot season. The 24-hour PM2.5 and metal(lloid) concentrations exceeded national and international guidelines to protect population health.


Asunto(s)
Contaminantes Atmosféricos , Estaciones del Año , Contaminantes Atmosféricos/análisis , Monitoreo del Ambiente/métodos , México , Material Particulado/análisis , Metales/análisis
15.
Toxicol Appl Pharmacol ; 410: 115354, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33271249

RESUMEN

Ethyl maltol (EM) is a flavoring agent commonly used in foods that falls under the generally recognized as safe category. It is added to many commercial e-cigarette vaping fluids and has been detected in the aerosols. Considering that EM facilitates heavy metal transport across plasma membranes, and that heavy metals have been detected in aerosols generated from e-cigarettes, this study examines whether EM enhances heavy metal mediated toxicity. A decrease in viability was observed in the Calu-6 and A549 lung epithelial cell lines co-exposed to EM and copper (Cu) but no decrease was observed after co-exposure to EM with iron (Fe). Interestingly, co-exposure to EM and Fe decreased viability of the HEK293 and IMR-90 fibroblast cell lines but co-exposure to EM and Cu did not. Increases in the apoptotic markers Annexin V staining and fragmented nuclei were observed in Calu-6 cells co-exposed to EM and Cu. Co-exposure to EM and Cu in Calu-6 cells resulted in DNA damage as indicated by activation of ATM and expression of γH2A.x foci. Finally, co-exposure to EM and Cu caused oxidative stress as indicated by increases in the generation of reactive oxygen species and the expression of ferritin light chain mRNA and hemeoxygenase-1 mRNA and protein. These data show that co-exposure to EM and Cu, at concentrations that are not toxic for either chemical individually, induce apoptosis and evoke oxidative stress and DNA damage in lung epithelial cells. We suggest that there is a greater risk of lung damage in users of c-cigarette who vape with vaping fluid containing EM.


Asunto(s)
Cobre/toxicidad , Citotoxinas/toxicidad , Pulmón/efectos de los fármacos , Pironas/toxicidad , Mucosa Respiratoria/efectos de los fármacos , Células A549 , Supervivencia Celular/efectos de los fármacos , Supervivencia Celular/fisiología , Relación Dosis-Respuesta a Droga , Sinergismo Farmacológico , Células HEK293 , Humanos , Pulmón/patología , Mucosa Respiratoria/patología
16.
Chem Res Toxicol ; 34(10): 2216-2226, 2021 10 18.
Artículo en Inglés | MEDLINE | ID: mdl-34610237

RESUMEN

The surge in electronic cigarette (e-cig) use in recent years has raised questions on chemical exposures that may result from vaping. Previous studies have focused on measuring known toxicants, particularly those present in traditional cigarettes, while fewer have investigated unknown compounds and transformation products formed during the vaping process in these diverse and constantly evolving products. The primary aim of this work was to apply liquid chromatography-high-resolution mass spectrometry (LC-HRMS) and chemical fingerprinting techniques for the characterization of e-liquids and aerosols from a selection of popular e-cig products. We conducted nontarget and quantitative analyses of tobacco-flavored e-liquids and aerosols generated using four popular e-cig products: one disposable, two pod, and one tank/mod. Aerosols were collected using a condensation device and analyzed in solution alongside e-liquids by LC-HRMS. The number of compounds detected increased from e-liquids to aerosols in three of four commercial products, as did the proportion of condensed-hydrocarbon-like compounds, associated with combustion. Kendrick mass defect analysis suggested that some of the additional compounds detected in aerosols belonged to homologous series resulting from decomposition of high-molecular-weight compounds during vaping. Lipids in inhalable aerosols have been associated with severe respiratory effects, and lipid-like compounds were observed in aerosols as well as e-liquids analyzed. Six potentially hazardous additives and contaminants, including the industrial chemical tributylphosphine oxide and the stimulant caffeine, were identified and quantified in the e-cig liquids and aerosols analyzed. The obtained findings demonstrate the potential of nontarget LC-HRMS to identify previously unknown compounds and compound classes in e-cig liquids and aerosols, which is critical for the assessment of chemical exposures resulting from vaping.


Asunto(s)
Aerosoles/análisis , Sistemas Electrónicos de Liberación de Nicotina , Aromatizantes/análisis , Cromatografía Liquida , Espectrometría de Masas
17.
Environ Sci Technol ; 55(12): 8090-8096, 2021 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-34018733

RESUMEN

Growing demand of Juul and other electronic cigarettes, despite critical knowledge gaps about their chemical composition, has led to concerns regarding their potential health effects. We introduce a novel analytical approach, runtime cavity ringdown spectroscopy (rtCRDS) for rapid detection of oxidative products in e-cigarette aerosols, to facilitate the study of aerosol from a single puff of e-liquid. We report a systematic investigation of three flavors of commercial Juul pods (Virginia tobacco, mango, and menthol) and known commercial e-liquid ingredients (propylene glycol (PG), vegetable glycerin (VG), nicotine, ethyl maltol, benzoic acid, and nicotine benzoate) vaped using Juul devices. Juul e-liquids and neat chemical additives spiked into a 30:70 PG/VG solution were vaped and their aerosols were collected in 1-L Tedlar gas bags and analyzed using rtCRDS. Acetaldehyde, formaldehyde, and acetone were identified as primary oxidative products in aerosolized PG/VG. Ethanol was detected as a major constituent of the three commercial Juul flavors. Spectral intensities of carbonyl compounds increased with the addition of spikes, benzoic acid, ethyl maltol, and nicotine to PG/VG, suggesting that oxidative product generation increases with common additives. The method of direct, rapid analysis of e-cig aerosols introduced here can be used to complement traditional methods in vaping exposures.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Vapeo , Aerosoles , Análisis Espectral , Virginia
18.
Environ Sci Technol ; 55(12): 8128-8138, 2021 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-34078083

RESUMEN

Hairdressers may be differentially exposed to phthalates through hair salon services provided and products used, yet no U.S. studies have investigated these exposures in this population. We characterized concentrations and exposure determinants to nine phthalate metabolites in postshift urine samples among 23 hairdressers from three Black and three Dominican salons, as well as a comparison group of 17 female office workers from the Maryland/Washington D.C. metropolitan area. Overall, hairdressers had higher metabolite concentrations than office workers. The geometric mean (GM) for monoethyl phthalate (MEP) was 10 times higher in hairdressers (161.4 ng/mL) than office workers (15.3 ng/mL). Hairdressers providing select services and using certain products had higher GM MEP concentrations than those who did not: permanent waves/texturizing (200.2 vs 115.4 ng/mL), chemical straightening/relaxing (181.6 vs 92.1 ng/mL), bleaching (182.3 vs 71.6 ng/mL), permanent hair color (171.9 vs 83.2 ng/mL), and Brazilian blowout/keratin treatments (181.4 vs 134.6 ng/mL). Interestingly, hairdressers providing natural services had lower GM MEP concentrations than those who did not: twists (129.1 vs 215.8 ng/mL), sister locs/locs (86.0 vs 241.9 ng/mL), and afros (94.7 vs 203.9 ng/mL). Larger studies are warranted to confirm our findings and identify disparities in occupational phthalate exposures.


Asunto(s)
Exposición Profesional , Ácidos Ftálicos , Negro o Afroamericano , Brasil , Exposición a Riesgos Ambientales , Femenino , Hispánicos o Latinos , Humanos , Maryland , Proyectos Piloto , Washingtón
19.
Indoor Air ; 31(4): 1144-1153, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33682973

RESUMEN

Hairdressers are exposed to particulate matter (PM), a known air pollutant linked to adverse health effects. Still, studies on occupational PM exposures in hair salons are sparse. We characterized indoor air PM concentrations in three salons primarily serving an African/African American (AA) clientele, and three Dominican salons primarily serving a Latino clientele. We also assessed the performance of low-cost sensors (uRAD, Flow, AirVisual) by comparing them to high-end sensors (DustTrak) to conduct air monitoring in each salon over 3 days to quantify work shift concentrations of PM2.5 , respirable PM (RPM), and PM10 . We observed high spatial and temporal variability in 30-min time-weighted average (TWA) RPM concentrations (0.18-5518 µg/m3 ). Readings for the uRAD and AirVisual sensors were highly correlated with the DustTrak (R2  = 0.90-0.99). RPM 8-hour TWAs ranged from 18 to 383 µg/m3 for AA salons, and 9-2115 µg/m3 for Dominican salons. Upper 95th percentiles of daily RPM exposures ranged from 439 to 2669 µg/m3 . The overall range of 30-min TWA PM2.5 and PM10 concentrations was 0.13-5497 and 0.36-,541 µg/m3 , respectively. Findings suggest that hairdressers could be overexposed to RPM during an 8-hour shift. Additional comprehensive monitoring studies are warranted to further characterize temporal and spatial variability of PM exposures in this understudied occupational population.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Exposición Profesional , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente , Maryland , Material Particulado/análisis , Proyectos Piloto
20.
Curr Allergy Asthma Rep ; 19(1): 9, 2019 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-30747291

RESUMEN

PURPOSE OF REVIEW: To review current indoor allergen sampling devices, including devices to measure allergen in reservoir and airborne dust, and personal sampling devices, with attention to sampling rationale and major indoor allergen size and characteristics. RECENT FINDINGS: While reservoir dust vacuuming samples and airborne dust volumetric air sampling remain popular techniques, recent literature describes sampling using furnace filters and ion-charging devices, both which help to eliminate the need for trained staff; however, variable correlation with reservoir dust and volumetric air sampling has been described. Personal sampling devices include intra-nasal samples and personal volumetric air samples. While these devices may offer better estimates of breathable allergens, they are worn for short periods of time and can be cumbersome. Reservoir dust sampling is inexpensive and is possible for families to perform. Airborne dust sampling can be more expensive and may better quantify cat, dog, and mouse allergen exposure. Personal sampling devices may offer a better representation of breathable air.


Asunto(s)
Contaminación del Aire Interior/efectos adversos , Alérgenos/inmunología , Animales , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA