Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(8): 586-597, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-37624856

RESUMEN

BACKGROUND AND AIMS: Benefit of tricuspid regurgitation (TR) correction and timing of intervention are unclear. This study aimed to compare survival rates after surgical or transcatheter intervention to conservative management according to a TR clinical stage as assessed using the TRI-SCORE. METHODS: A total of 2,413 patients with severe isolated functional TR were enrolled in TRIGISTRY (1217 conservatively managed, 551 isolated tricuspid valve surgery, and 645 transcatheter valve repair). The primary endpoint was survival at 2 years. RESULTS: The TRI-SCORE was low (≤3) in 32%, intermediate (4-5) in 33%, and high (≥6) in 35%. A successful correction was achieved in 97% and 65% of patients in the surgical and transcatheter groups, respectively. Survival rates decreased with the TRI-SCORE in the three treatment groups (all P < .0001). In the low TRI-SCORE category, survival rates were higher in the surgical and transcatheter groups than in the conservative management group (93%, 87%, and 79%, respectively, P = .0002). In the intermediate category, no significant difference between groups was observed overall (80%, 71%, and 71%, respectively, P = .13) but benefit of the intervention became significant when the analysis was restricted to patients with successful correction (80%, 81%, and 71%, respectively, P = .009). In the high TRI-SCORE category, survival was not different to conservative management in the surgical and successful repair group (61% and 68% vs 58%, P = .26 and P = .18 respectively). CONCLUSIONS: Survival progressively decreased with the TRI-SCORE irrespective of treatment modality. Compared to conservative management, an early and successful surgical or transcatheter intervention improved 2-year survival in patients at low and, to a lower extent, intermediate TRI-SCORE, while no benefit was observed in the high TRI-SCORE category.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Resultado del Tratamiento , Cateterismo Cardíaco
2.
Catheter Cardiovasc Interv ; 103(7): 1138-1144, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38695165

RESUMEN

Following the introduction in the latest European and American guidelines, transcatheter edge-to-edge repair has become a valid alternative to surgery for ineligible patients. Among the available technologies, MitraClip (Abbott) was the first to be introduced for the percutaneous treatment of mitral regurgitation with the edge-to-edge technique. Although its safety and effectiveness has been widely demonstrated, the optimal procedural results are highly dependent from operators' experience. In this manuscript, we provide a full guide of advanced steering maneuvers of MitraClip in different scenarios of transseptal puncture.


Asunto(s)
Cateterismo Cardíaco , Catéteres Cardíacos , Insuficiencia de la Válvula Mitral , Válvula Mitral , Punciones , Humanos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Diseño de Equipo , Tabiques Cardíacos/cirugía , Tabiques Cardíacos/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Resultado del Tratamiento
3.
Eur Heart J ; 44(10): 822-832, 2023 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-36445158

RESUMEN

AIMS: The impact of sexuality in patients with significant tricuspid regurgitation (TR) undergoing transcatheter tricuspid valve intervention (TTVI) is unknown. The aim of this study was to investigate sex-specific outcomes in patients with significant TR treated with TTVI vs. medical therapy alone. METHODS AND RESULTS: The Transcatheter Tricuspid Valve Therapies (TriValve) registry collected data on patients with significant TR from 24 centres who underwent TTVI from 2016 to 2021. A control cohort was formed by medically managed patients with ≥severe isolated TR diagnosed in 2015-18. The primary endpoint was freedom from all-cause mortality. Secondary endpoints were heart failure (HF) hospitalization, New York Heart Association (NYHA) functional status, and TR severity. One-year outcomes were assessed for the TriValve cohort and compared with the control cohort with the inverse probability of treatment weighting (IPTW). A total of 556 and 2072 patients were included from the TriValve and control groups, respectively. After TTVI, there was no difference between women and men in 1-year freedom from all-cause mortality 80.9% vs. 77.9%, P = 0.56, nor in HF hospitalization (P = 0.36), NYHA Functional Classes III and IV (P = 0.17), and TR severity >2+ at last follow-up (P = 0.42). Multivariable Cox-regression weighted by IPTW showed improved 1-year survival after TTVI compared with medical therapy alone in both women (adjusted hazard ratio 0.45, 95% confidence interval 0.23-0.83, P = 0.01) and men (adjusted hazard ratio 0.42, 95% confidence interval 0.18-0.89, P = 0.03). CONCLUSION: After TTVI in high-risk patients, there were no sex-related differences in terms of survival, HF hospitalization, functional status, and TR reduction up to 1 year. The IPTW analysis shows a survival benefit of TTVI over medical therapy alone in both women and men.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Masculino , Humanos , Femenino , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Sistema de Registros , Insuficiencia Cardíaca/complicaciones
4.
Int J Mol Sci ; 24(13)2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37446157

RESUMEN

Atherosclerotic cardiovascular disease is the most common cause of morbidity and death worldwide. Recent studies have demonstrated that this chronic inflammatory disease of the arterial wall can be controlled through the modulation of immune system activity. Many patients with cardiovascular disease remain at elevated risk of recurrent events despite receiving current, state-of-the-art preventive medical treatment. Much of this residual risk is attributed to inflammation. Therefore, finding new treatment strategies for this category of patients became of common interest. This review will discuss the experimental and clinical data supporting the possibility of developing immune-based therapies for lowering cardiovascular risk, explicitly focusing on vaccination strategies.


Asunto(s)
Aterosclerosis , Inmunomodulación , Humanos , Aterosclerosis/inmunología , Aterosclerosis/prevención & control , Aterosclerosis/terapia , Factores de Riesgo de Enfermedad Cardiaca , Inflamación , Vacunación/tendencias , Inmunidad Innata/inmunología , Inmunidad Adaptativa/inmunología , Inmunidad Humoral/inmunología , Autoantígenos/inmunología , Ensayos Clínicos como Asunto , Vacunas/inmunología , Vacunas/uso terapéutico
5.
Biol Chem ; 403(5-6): 479-494, 2022 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-35312243

RESUMEN

One of the most widely used epitope tags is the myc-tag, recognized by the anti-c-Myc hybridoma antibody Myc1-9E10. Combining error-prone PCR, DNA shuffling and phage display, we generated an anti-c-Myc antibody variant (Hyper-Myc) with monovalent affinity improved to 18 nM and thermal stability increased by 37%. Quantification of capillary immunoblots and by flow cytometry demonstrated improved antigen detection by Hyper-Myc. Further, three different species variants of this antibody were generated to allow the use of either anti-human, anti-mouse or anti-rabbit Fc secondary antibodies for detection. We characterized the specificity of both antibodies in depth: individual amino acid exchange mapping demonstrated that the recognized epitope was not changed by the in vitro evolution process. A laser printed array of 29,127 different epitopes representing all human linear B-cell epitopes of the Immune Epitope Database allowing to chart unwanted reactivities with mimotopes showed these to be very low for both antibodies and not increased for Hyper-Myc despite its improved affinity. The very low background reactivity of Hyper-Myc was confirmed by staining of myc-tag transgenic zebrafish whole mounts. Hyper-Myc retains the very high specificity of Myc1-9E10 while allowing myc-tag detection at lower concentrations and with either anti-mouse, anti-rabbit or anti human secondary antibodies.


Asunto(s)
Anticuerpos Monoclonales , Pez Cebra , Animales , Anticuerpos Monoclonales/química , Mapeo Epitopo , Epítopos , Ratones , Proteínas Proto-Oncogénicas c-myc/genética , Conejos
6.
Biol Chem ; 403(5-6): 455-477, 2022 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-33759431

RESUMEN

Antibody display technologies enable the successful isolation of antigen-specific antibodies with therapeutic potential. The key feature that facilitates the selection of an antibody with prescribed properties is the coupling of the protein variant to its genetic information and is referred to as genotype phenotype coupling. There are several different platform technologies based on prokaryotic organisms as well as strategies employing higher eukaryotes. Among those, phage display is the most established system with more than a dozen of therapeutic antibodies approved for therapy that have been discovered or engineered using this approach. In recent years several other technologies gained a certain level of maturity, most strikingly mammalian display. In this review, we delineate the most important selection systems with respect to antibody generation with an emphasis on recent developments.


Asunto(s)
Anticuerpos , Biblioteca de Péptidos , Animales , Anticuerpos/genética , Anticuerpos/uso terapéutico , Mamíferos/genética
7.
J Card Surg ; 37(7): 2053-2059, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35249238

RESUMEN

INTRODUCTION: The proportion of patients with symptomatic severe aortic stenosis treated by transcatheter aortic valve replacement (TAVR) is increasing, driven by favorable outcomes from randomized trials and current valve guidelines recommendations. Despite device and technique improvements having reduced procedural morbidities, complications during or immediately after TAVR still carries significant mortality risk. METHODS: We propose a check-list of essential items to anticipate potentially life-threatening complications in TAVR. RESULTS: Purpose of this review is to discuss the most common life-threatening complications during TAVR from a troubleshooting perspective, depicting the minimum required equipment needed in emergency situations. CONCLUSIONS: Prevention of complications remains the most important strategy to optimize outcomes in TAVR procedures. Each specialized Center should institute and make easily accessible standardized emergency kits for the most common life-threatening conditions during TAVR that should be readily available in the cath-lab or hybrid operating room.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Humanos , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 98(6): E971-E976, 2021 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-34533899

RESUMEN

Optimal transseptal puncture (TSP) position on the interatrial septum as well as proper catheter direction and maneuverability in the left atrium (LA) are key elements for successful mitral valve (MV) interventions. TSP is usually performed from the right femoral vein being more comfortable for the operator and easier to reach the fossa ovalis. In the cases reported, TSP was performed from left femoral vein (LFV) to improve delivery system maneuverability and trajectory inside the LA in the context of MV repair with MitraClip. According to this early experience, LFV approach might be considered as first choice or as an alternative solution in patients in whom a higher position of the delivery system relative to the mitral annulus is needed.


Asunto(s)
Tabique Interatrial , Válvula Mitral , Tabique Interatrial/diagnóstico por imagen , Tabique Interatrial/cirugía , Cateterismo Cardíaco , Vena Femoral/diagnóstico por imagen , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento
9.
J Enzyme Inhib Med Chem ; 36(1): 785-789, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33733989

RESUMEN

Acute Coronary Syndromes (ACS) with plaque erosion display dysregulated hyaluronan metabolism, with increased hyaluronidase-2 (HYAL2) expression. However, the expression and the role of this enzyme on platelets has never been explored. We evaluated the platelet's HYAL2 (pltHYAL2) levels on I) stable angina (SA) and II) ACS patients, furtherly sub-grouped in Intact-Fibrous-Cap (IFC) and Ruptured-Fibrous-Cap (RFC), according to Optical Coherence Tomography. We assessed the HYAL2 role through an in vitro model setting of co-cultured monocytes and platelets, before and after treatment with low-molecular-weight hyaluronic acid (HA) as pro-inflammatory stimulus and with or without HYAL2-antibody to inhibit HYAL2 activity. ACS patients exhibit higher pltHYAL2 levels comparing to SA, with the higher expression for IFC group. The addition of HYAL2-antibody significantly reduced the percentage of monocyte-platelet binding, suggesting that pltHYAL2 enrichment at the site of the culprit lesion is a key mediator in the systemic thrombo-inflammatory status of ACS presenting with plaque erosion.


Asunto(s)
Síndrome Coronario Agudo/metabolismo , Moléculas de Adhesión Celular/metabolismo , Hialuronoglucosaminidasa/metabolismo , Monocitos/metabolismo , Síndrome Coronario Agudo/tratamiento farmacológico , Síndrome Coronario Agudo/patología , Moléculas de Adhesión Celular/antagonistas & inhibidores , Moléculas de Adhesión Celular/sangre , Técnicas de Cocultivo , Proteínas Ligadas a GPI/antagonistas & inhibidores , Proteínas Ligadas a GPI/sangre , Proteínas Ligadas a GPI/metabolismo , Humanos , Ácido Hialurónico/metabolismo , Ácido Hialurónico/farmacología , Hialuronoglucosaminidasa/antagonistas & inhibidores , Hialuronoglucosaminidasa/sangre , Monocitos/efectos de los fármacos , Agregación Plaquetaria/efectos de los fármacos
10.
J Neurosci ; 39(20): 3948-3969, 2019 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-30862666

RESUMEN

Purkinje cells (PCs) are primarily affected in neurodegenerative spinocerebellar ataxias (SCAs). For generating animal models for SCAs, genetic regulatory elements specifically targeting PCs are required, thereby linking pathological molecular effects with impaired function and organismic behavior. Because cerebellar anatomy and function are evolutionary conserved, zebrafish represent an excellent model to study SCAs in vivo We have isolated a 258 bp cross-species PC-specific enhancer element that can be used in a bidirectional manner for bioimaging of transgene-expressing PCs in zebrafish (both sexes) with variable copy numbers for tuning expression strength. Emerging ectopic expression at high copy numbers can be further eliminated by repurposing microRNA-mediated posttranslational mRNA regulation.Subsequently, we generated a transgenic SCA type 13 (SCA13) model, using a zebrafish-variant mimicking a human pathological SCA13R420H mutation, resulting in cell-autonomous progressive PC degeneration linked to cerebellum-driven eye-movement deficits as observed in SCA patients. This underscores that investigating PC-specific cerebellar neuropathologies in zebrafish allows for interconnecting bioimaging of disease mechanisms with behavioral analysis suitable for therapeutic compound testing.SIGNIFICANCE STATEMENT SCA13 patients carrying a KCNC3R420H allele have been shown to display mid-onset progressive cerebellar atrophy, but genetic modeling of SCA13 by expressing this pathogenic mutant in different animal models has not resulted in neuronal degeneration so far; likely because the transgene was expressed in heterologous cell types. We developed a genetic system for tunable PC-specific coexpression of several transgenes to manipulate and simultaneously monitor cerebellar PCs. We modeled a SCA13 zebrafish accessible for bioimaging to investigate disease progression, revealing robust PC degeneration, resulting in impaired eye movement. Our transgenic zebrafish mimicking both neuropathological and behavioral changes manifested in SCA-affected patients will be suitable for investigating causes of cerebellar diseases in vivo from the molecular to the behavioral level.


Asunto(s)
Cerebelo/metabolismo , Modelos Animales de Enfermedad , Células de Purkinje/metabolismo , Ataxias Espinocerebelosas/congénito , Animales , Animales Modificados Genéticamente , Cerebelo/crecimiento & desarrollo , Cerebelo/fisiopatología , Femenino , Regulación de la Expresión Génica , Masculino , ARN Mensajero/metabolismo , Elementos Reguladores de la Transcripción , Canales de Potasio Shaw/genética , Ataxias Espinocerebelosas/genética , Ataxias Espinocerebelosas/metabolismo , Pez Cebra , Proteínas de Pez Cebra/genética
11.
Catheter Cardiovasc Interv ; 96(2): 459-470, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31925991

RESUMEN

OBJECTIVES: To describe and report the results of an original technique for trans-femoral (TF) transcatheter-aortic-valve-replacement (TAVR). BACKGROUND: TF approach represents the commonest TAVR technique. The best technique for TF-TAVR is not recognized. METHODS: We developed a less-invasive totally-endovascular (LITE) technique for TF-TAVR. The key aspects are: precise TAVR access puncture using angiographic-guidewire-ultrasound guidance radial approach as the "secondary access" (to guide valve positioning, to check femoral-access hemostasis and to manage eventual access-site complications) non-invasive pacing (by retrograde left ventricle stimulation or by definitive pace-maker external programmer) The LITE technique has been systematically adopted at our Institution. Procedure details, complications and clinical events occurring during hospitalization were prospectively recorded. Major vascular complications and life-threatening or major bleedings were the primary study end-points. RESULTS: A total of 153 consecutive patients referred for TF-TAVR were approached using the LITE technique. Mean predicted surgical operative mortality was 4.9% and mean TAVR predicted mortality was 3.9%. In 132 (86.3%) patients, TAVR was completed without the need for additional femoral artery access or transvenous temporary pace-maker implantation. Major vascular complications occurred in 2 (1.3%), life-threatening or major bleedings occurred in 4 (2.6%) patients. All-cause death occurred in 3 patients (2.0%). CONCLUSIONS: TF-TAVR according to LITE technique is feasible and is associated with very low rates of vascular or bleeding complications.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Estimulación Cardíaca Artificial , Cateterismo Periférico , Arteria Femoral , Arteria Radial , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Estimulación Cardíaca Artificial/efectos adversos , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Femenino , Arteria Femoral/diagnóstico por imagen , Humanos , Masculino , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/prevención & control , Estudios Prospectivos , Punciones , Arteria Radial/diagnóstico por imagen , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
12.
Biospektrum (Heidelb) ; 26(4): 416-417, 2020.
Artículo en Alemán | MEDLINE | ID: mdl-32834539

RESUMEN

Today, recombinant antibodies can replace animal-derived primary antibodies in almost all applications. Due to their monoclonal origin and always known sequence, they offer optimal reproducibility. In contrast, almost all secondary antibodies are still made from animal sera. Multiclonal antibodies made by animal-free recombinant methods here offer a higher quality replacement for serum-derived secondary antibodies.

13.
J Interv Cardiol ; 2019: 5243913, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31772533

RESUMEN

OBJECTIVE: To investigate the effect of extent of revascularization in complex high-risk indicated patients (CHIP) undergoing Impella-protected percutaneous coronary intervention (PCI). BACKGROUND: Complete revascularization has been shown to be associated with improved outcomes. However, the impact of more complete revascularization during Impella-protected PCI in CHIP has not been reported. METHODS: A total of 86 CHIP undergoing elective PCI with Impella 2.5 or Impella CP between April 2007 and December 2016 from 2 high volume Italian centers were included. Baseline, procedural, and clinical outcomes data were collected retrospectively. Completeness of coronary revascularization was assessed using the British Cardiovascular Intervention Society myocardial jeopardy score (BCIS-JS) derived revascularization index (RI). The primary end-point was all-cause mortality. A multivariate regression model was used to identify independent predictors of mortality. RESULTS: All patients had multivessel disease and were considered unsuitable for surgery. At baseline, 44% had left main disease, 78% had LVEF ≤ 35%, and mean BCIS-JS score was 10±2. The mean BCIS-JS derived RI was 0.7±0.2 and procedural complications were uncommon. At 14-month follow-up, all-cause mortality was 10.5%. At follow-up, 67.4% of CHIP had LVEF ≥ 35% compared to 22.1% before Impella protected-PCI. Higher BCIS-JS RI was significantly associated with LVEF improvement (p=0.002). BCIS-JS RI of ≤ 0.8 (HR 0.11, 95% CI 0.01- 0.92, and p = 0.042) was an independent predictor of mortality. CONCLUSIONS: These results support the practice of percutaneous Impella use for protected PCI in CHIP. A more complete revascularization was associated with significant LVEF improvement and survival.


Asunto(s)
Enfermedad de la Arteria Coronaria , Corazón Auxiliar , Intervención Coronaria Percutánea , Anciano , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/cirugía , Femenino , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Sistema de Registros/estadística & datos numéricos , Estudios Retrospectivos , Medición de Riesgo/métodos
14.
Dev Biol ; 430(1): 18-31, 2017 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-28802829

RESUMEN

Although having great potential for live cell imaging to address numerous cell biological questions with high spatial and temporal resolution, primary cell cultures of zebrafish embryos are not widely used. We present an easy-to-use protocol for preparing primary cell cultures of 2 dpf zebrafish embryos allowing for live cell imaging of fully differentiated cells such as neurons and myocytes. We demonstrate that different cell types can be identified by morphology and expression of transgenic cell type-specific fluorescent reporters and that fluorescent cells can be sorted by flow cytometry to prepare an enriched culture. To facilitate subcellular imaging in live primary cells, we successfully tested a selection of fluorescent vital dyes. Most importantly, we demonstrate that zebrafish primary cells can be transfected efficiently with expression constructs allowing for visualizing subcellular structures with fluorescent marker proteins for time lapse imaging. We propose zebrafish primary cell culture as a versatile tool to address cell biological questions in combination with a powerful in vivo model.


Asunto(s)
Embrión no Mamífero/citología , Imagenología Tridimensional , Cultivo Primario de Células/métodos , Transfección/métodos , Pez Cebra/embriología , Animales , Forma de la Célula , Células Cultivadas , Electroporación , Embrión no Mamífero/metabolismo , Citometría de Flujo , Macrófagos/citología , Neuronas Motoras/citología , Neuroglía/citología , Células de Purkinje/citología , Coloración y Etiquetado , Fracciones Subcelulares/metabolismo , Transgenes
15.
Cardiology ; 130(4): 201-6, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25790943

RESUMEN

OBJECTIVES: To assess the effects of isosorbide-5-mononitrate (ISMN) in patients with microvascular angina (MVA). METHODS: We randomized 20 MVA patients, treated with a ß-blocker or a calcium antagonist, to 60 mg slow-release ISMN (halved to 30 mg if not tolerated) or placebo once a day for 4 weeks; the patients were then switched to the other treatment for another 4 weeks. Their clinical status was assessed with the Seattle Angina Questionnaire (SAQ) and the EuroQoL score for quality of life. The exercise stress test (EST), coronary blood flow (CBF) response to nitrate and the cold pressor test (CPT), brachial artery flow-mediated dilation (FMD) and nitrate-mediated dilation (NMD) were also assessed. RESULTS: Nine patients (45%) did not complete the ISMN phase due to side effects; 2 patients refused a follow-up. Nine patients completed the study. The SAQ and EuroQoL scores were significantly better with ISMN than with placebo, although the differences were small. No differences were found between the treatments in the EST results, CBF response to nitroglycerin (p = 0.55) and the CPT (p = 0.54), FMD (p = 0.26) and NMD (p = 0.35). CONCLUSIONS: In this study, a high proportion of MVA patients showed an intolerance to ISMN; in those tolerating the drug, significant effects on their angina status were observed, but the benefit appeared to be modest and independent of effects on coronary microvascular function.


Asunto(s)
Dinitrato de Isosorbide/análogos & derivados , Angina Microvascular/tratamiento farmacológico , Vasodilatadores/efectos adversos , Vasodilatadores/uso terapéutico , Antagonistas Adrenérgicos beta/uso terapéutico , Anciano , Arteria Braquial/diagnóstico por imagen , Bloqueadores de los Canales de Calcio/uso terapéutico , Estudios Cruzados , Método Doble Ciego , Ecocardiografía Doppler , Prueba de Esfuerzo , Femenino , Humanos , Dinitrato de Isosorbide/efectos adversos , Dinitrato de Isosorbide/uso terapéutico , Masculino , Persona de Mediana Edad , Calidad de Vida
16.
Cardiology ; 129(1): 20-4, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24968863

RESUMEN

OBJECTIVES: In this study, we assessed whether any abnormalities in coronary microvascular and peripheral vasodilator functions are present in patients with variant angina (VA) caused by epicardial coronary artery spasm (CAS). METHODS: We studied 23 patients with VA (i.e. angina at rest, ST-segment elevation during angina attacks and documented occlusive CAS at angiography) and 18 matched healthy controls. Endothelium-dependent and -independent coronary microvascular function was assessed by measuring coronary blood flow (CBF) response to adenosine and the cold pressor test (CPT) in the left anterior descending artery by transthoracic Doppler echocardiography. Systemic endothelium-dependent and -independent arterial dilator function was assessed by measuring brachial flow-mediated dilation (FMD) and nitrate-mediated dilation (NMD), respectively. RESULTS: In VA patients, CBF responses to both adenosine (1.71 ± 0.25 vs. 2.97 ± 0.80, p < 0.01) and CPT (1.68 ± 0.23 vs. 2.58 ± 0.60, p < 0.01) were reduced compared to controls. Brachial FMD was also lower (3.87 ± 2.06 vs. 8.51 ± 2.95%, p < 0.01), but NMD was higher (16.7 ± 1.8 vs. 11.9 ± 1.4%, p < 0.01) in patients compared to controls. Differences were independent of the presence of coronary atherosclerotic lesions at angiography. CONCLUSIONS: Our data show that patients with VA have a generalized vascular dysfunction that involves both peripheral artery vessels and coronary microcirculation.


Asunto(s)
Angina Pectoris Variable/fisiopatología , Arteria Braquial/fisiopatología , Circulación Coronaria/fisiología , Vasoespasmo Coronario/complicaciones , Microcirculación/fisiología , Flujo Sanguíneo Regional/fisiología , Anciano , Angina Pectoris Variable/etiología , Estudios de Casos y Controles , Vasoespasmo Coronario/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Vasodilatación/fisiología
17.
Minerva Cardiol Angiol ; 72(2): 172-181, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38088090

RESUMEN

BACKGROUND: Paravalvular leakage (PVL) is a common finding after transcatheter aortic valve replacement (TAVR) and affects late clinical outcome. It is more frequent with self-expandable (SE) transcatheter-heart-valve (THV). Few is known about SE-THV expansion after implantation. The purpose is to assess SE-THV frame expansion and its possible influence on PVL. METHODS: We designed a prospective pilot study to assess the time-course of SE-THV frame dimensions and PVL after TAVR. Consecutive patients undergoing TAVR with SE-THV were enrolled. Prosthesis fluoroscopy and echocardiography were prospectively performed immediately after TAVR (T0) and before discharge (T1) to grade PVL. Prosthesis diameters were assessed in 2 fluoroscopic orthogonal views. PVL reduction ≥1+ from T0 to T1 at echocardiography was the primary study endpoint. RESULTS: Twenty-five patients were enrolled. Mean interval between T0 and T1 evaluations was 5 days. Grade 1 or 2 was present in 76% of patients at T0 and in 68% at T1 (P=0.034). A total of 7 patients (28%) improved PVL ≥1 grade from T0 to T1. Differences between T0 and T1 fluoroscopic diameters were not statistically significant. When comparing the diameter changes according to PVL evolution, patients with PVL improvement (as compared with those without) had significantly larger minimum diameter increase at both annulus/inflow (P=0.016) and outflow/distal edge (P=0.027). CONCLUSIONS: PVL may improve in the early days after SE-THV and those patients with PVL improvement may have THV frame expansion. Further studies are needed to confirm such preliminary observations and to establish the clinical relevance of this phenomenon.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estudios Prospectivos , Proyectos Piloto , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Diseño de Prótesis
18.
Int J Cardiol ; 412: 132330, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38964558

RESUMEN

BACKGROUND: Using three-dimensional (3D) modalities for optimal pre-procedure planning in transcatheter aortic valve replacement (TAVR) is critical for procedural success. However, current methods rely on visualizing images on a two-dimensional screen, using shading and colors to create the illusion of 3D, potentially impeding the accurate comprehension of the actual anatomy structures. In contrast, a new Mixed Reality (MxR) based software enables accurate 3D visualization, imaging manipulation, and quantification of measurements. AIMS: The study aims to evaluate the feasibility, reproducibility, and accuracy of dimensions of the aortic valve complex as measured with a new holographic MxR software (ARTICOR®, Artiness srl, Milano, Italy) compared to a widely used software for pre-operative sizing and planning (3mensio Medical Imaging BV, Bilthoven, The Netherlands). METHODS: This retrospective, observational, double-center study enrolled 100 patients with severe aortic stenosis who underwent cardiac computed tomography (CCT) before TAVR. The CCT datasets of volumetric aortic valve images were analyzed using 3Mensio and newly introduced MxR-based software. RESULTS: Ninety-eight percent of the CCT datasets were successfully converted into holographic models. A higher level of agreement between the two software systems was observed for linear metrics (short, long, and average diameter). In comparison, agreement was lower for area, perimeter, and annulus-to-coronary ostia distance measurements. Notably, the annulus area, annular perimeter, left ventricular outflow tract (LVOT) area, and LVOT perimeter were significantly and consistently smaller with the MxR-based software compared to the 3Mensio. Excellent interobserver reliability was demonstrated for most measurements, especially for direct linear measurements. CONCLUSIONS: Linear measurements of the aortic valve complex using MxR-based software are reproducible compared to the standard CCT dataset analyzed with 3Mensio. MxR-based software could represent an accurate tool for the pre-procedural planning of TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Holografía , Reemplazo de la Válvula Aórtica Transcatéter , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Humanos , Estudios Retrospectivos , Holografía/métodos , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Masculino , Anciano de 80 o más Años , Anciano , Imagenología Tridimensional/métodos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Reproducibilidad de los Resultados , Realidad Aumentada , Programas Informáticos
19.
JACC Cardiovasc Interv ; 17(12): 1485-1495, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38752971

RESUMEN

BACKGROUND: The safety profile of transcatheter tricuspid valve (TTV) repair techniques is well established, but residual tricuspid regurgitation (TR) remains a concern. OBJECTIVES: The authors sought to assess the impact of residual TR severity post-TTV repair on survival. METHODS: We evaluated the survival rate at 2 years of 613 patients with severe isolated functional TR who underwent TTV repair in TRIGISTRY according to the severity of residual TR at discharge using a 3-grade (mild, moderate, and severe) or 4-grade scheme (mild, mild to moderate, moderate to severe, and severe). RESULTS: Residual TR was none/mild in 33%, moderate in 52%, and severe in 15%. The 2-year adjusted survival rates significantly differed between the 3 groups (85%, 70%, and 44%, respectively; restricted mean survival time [RMST]: P = 0.0001). When the 319 patients with moderate residual TR were subdivided into mild to moderate (n = 201, 33%) and moderate to severe (n = 118, 19%), the adjusted survival rate was also significantly different between groups (85%, 80%, 55%, and 44%, respectively; RMST: P = 0.001). Survival was significantly lower in patients with moderate to severe residual TR compared to patients with mild to moderate residual TR (P = 0.006). No difference in survival rates was observed between patients with no/mild and mild to moderate residual TR (P = 0.67) or between patients with moderate to severe and severe residual TR (P = 0.96). CONCLUSIONS: The moderate residual TR group was heterogeneous and encompassed patients with markedly different clinical outcomes. Refining TR grade classification with a more granular 4-grade scheme improved outcome prediction. Our results highlight the importance of achieving a mild to moderate or lower residual TR grade during TTV repair, which could define a successful intervention.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Índice de Severidad de la Enfermedad , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/mortalidad , Masculino , Femenino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Válvula Tricúspide/fisiopatología , Anciano , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Cateterismo Cardíaco/instrumentación , Factores de Tiempo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Factores de Riesgo , Anciano de 80 o más Años , Persona de Mediana Edad , Medición de Riesgo , Sistema de Registros
20.
Int J Cardiol ; 405: 131934, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38437953

RESUMEN

AIMS: T-TEER is an effective therapy for the treatment of tricuspid regurgitation (TR). However, the effects of leaflets clipping on tricuspid valve annulus (TA) have not been investigated in detail. The aim of this study is to investigate the effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on TA diameter. METHODS AND RESULTS: The TriValve registry (Transcatheter Tricuspid Valve Therapies, NCT03416166) collected 556 patients from 22 European and North American centres undergoing transcatheter tricuspid valve interventions from 2016 to 2022. Patients undergoing T-TEER with available pre- and post-procedural data on TA diameter measured in the apical 4-chamber view on transthoracic echocardiography were selected for this study. Primary end-point was the reduction of TA diameter after T-TEER. A total of 186 patients were included in the study. In 115 patients (62%) TA diameter was reduced by at least 1 mm as compared to baseline. A significant reduction of TA dimension was observed following T-TEER (mean 2.3 mm [from pre-procedural diameter 46.7 mm to post-procedural diameter 44.4 mm], p < 0.001). In particular, the greatest reduction was observed in those with T-TEER in antero-septal commissure (mean 2.7 mm [from 47.1 mm to 44.4 mm], p < 0.001) as compared to those combining both antero-septal and postero-septal commissures (mean 1.4, from 46.0 mm to 44.6 mm, P = 0.06). A significant reduction of TA dimension was recorded in patients with 1 or 2 clips implanted but not in those patients with ≥3 clips implanted. CONCLUSIONS: In almost two third of patients T-TEER reduces TA diameter in addition to leaflet approximation. CONDENSED ABSTRACT: The effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on tricuspid valve annulus (TA) have not been studied in details. This study investigates TA diameter as measured in apical 4-chamber view on transthoracic echocardiography before and after T-TEER. A total of 186 patients from the TriValve registry were included in the study. The study results show that 62% of patients have a TA reduction after T-TEER, especially in those receiving 1 or 2 clips in the antero-septal commissure. These suggest that T-TEER reduces tricuspid regurgitation not only by approximation of leaflets, but also by TA diameter reduction.


Asunto(s)
Cateterismo Cardíaco , Sistema de Registros , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Masculino , Femenino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Anciano , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Anciano de 80 o más Años , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Persona de Mediana Edad , Ecocardiografía/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA