Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Ecol Appl ; 32(4): e2577, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35191120

RESUMEN

Risk assessments are fundamental to invasive species management and are underpinned by comprehensive characterization of invasive species impacts. Our understanding of the impacts of invasive species is growing constantly, and several recently developed frameworks offer the opportunity to systematically categorize environmental and socioeconomic impacts of invasive species. Invasive ants are among the most widespread and damaging invaders. Although a handful of species receives most of the policy attention, nearly 200 species have established outside their native range. Here, we provide a global, comprehensive assessment of the impacts of ants and propose a priority list of risk species. We used the Socioeconomic Impact Classification for Alien Taxa (SEICAT), Environmental Impact Classification for Alien Taxa (EICAT) and Generic Impact Scoring System (GISS) to analyze 642 unique sources for 100 named species. Different methodologies provided generally consistent results. The most frequently identified socioeconomic impacts were to human health. Environmental impacts were primarily on animal and plant populations, with the most common mechanisms being predation and competition. Species recognized as harmful nearly 20 years ago featured prominently, including Wasmannia auropunctata (little fire ant, electric ant), Solenopsis invicta (red imported fire ant), Anoplolepis gracilipes (yellow crazy ant), and Pheidole megacephala (African big-headed ant). All these species except W. auropunctata have been implicated in local extinctions of native species. Although our assessments affirmed that the most serious impacts have been driven by a small number of species, our results also highlighted a substantial number of less well publicized species that have had major environmental impacts and may currently be overlooked when prioritizing prevention efforts. Several of these species were ranked as high or higher than some of the previously recognized "usual suspects," most notably Nylanderia fulva (tawny crazy ant). We compared and combined our assessments with trait-based profiles and other lists to propose a consensus set of 31 priority species. Ever-increasing global trade contributes to growing rates of species introductions. The integrated approaches we used can contribute to robust, holistic risk assessments for many taxa entrained in these pathways.


Asunto(s)
Hormigas , Animales , Especies Introducidas , Medición de Riesgo , Factores Socioeconómicos
2.
NMR Biomed ; 28(1): 54-62, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25328128

RESUMEN

Skin sodium (Na(+) ) storage, as a physiologically important regulatory mechanism for blood pressure, volume regulation and, indeed, survival, has recently been rediscovered. This has prompted the development of MRI methods to assess Na(+) storage in humans ((23) Na MRI) at 3.0 T. This work examines the feasibility of high in-plane spatial resolution (23) Na MRI in skin at 7.0 T. A two-channel transceiver radiofrequency (RF) coil array tailored for skin MRI at 7.0 T (f = 78.5 MHz) is proposed. Specific absorption rate (SAR) simulations and a thorough assessment of RF power deposition were performed to meet the safety requirements. Human skin was examined in an in vivo feasibility study using two-dimensional gradient echo imaging. Normal male adult volunteers (n = 17; mean ± standard deviation, 46 ± 18 years; range, 20-79 years) were investigated. Transverse slices of the calf were imaged with (23) Na MRI using a high in-plane resolution of 0.9 × 0.9 mm(2) . Skin Na(+) content was determined using external agarose standards covering a physiological range of Na(+) concentrations. To assess the intra-subject reproducibility, each volunteer was examined three to five times with each session including a 5-min walk and repositioning/preparation of the subject. The age dependence of skin Na(+) content was investigated. The (23) Na RF coil provides improved sensitivity within a range of 1 cm from its surface versus a volume RF coil which facilitates high in-plane spatial resolution imaging of human skin. Intra-subject variability of human skin Na(+) content in the volunteer population was <10.3%. An age-dependent increase in skin Na(+) content was observed (r = 0.78). The assignment of Na(+) stores with (23) Na MRI techniques could be improved at 7.0 T compared with current 3.0 T technology. The benefits of such improvements may have the potential to aid basic research and clinical applications designed to unlock questions regarding the Na(+) balance and Na(+) storage function of skin.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Piel/metabolismo , Sodio/metabolismo , Adulto , Anciano , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Protones , Ondas de Radio , Reproducibilidad de los Resultados , Relación Señal-Ruido , Adulto Joven
3.
Magn Reson Med ; 72(1): 276-90, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23904404

RESUMEN

PURPOSE: To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T. METHODS: The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1 (+) field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study. RESULTS: Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm(3) for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly. CONCLUSION: The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T.


Asunto(s)
Corazón , Imagen por Resonancia Cinemagnética/instrumentación , Adulto , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Voluntarios Sanos , Humanos , Aumento de la Imagen/instrumentación , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Ondas de Radio , Transductores
4.
Magn Reson Med ; 65(4): 1166-72, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21413081

RESUMEN

A novel method is presented for the three-dimensional mapping of the B(1) -field of a transmit radio-frequency MR coil. The method is based on the acquisition of phase images, where the effective flip angle is encoded in the phase of the nonselective hard pulse excitation. The method involves the application of a rectangular composite pulse as excitation in a three-dimensional gradient recall echo to produce measurable phase angle variation. However, such a pulse may significantly increase the radio-frequency power deposition in excess of the standard acceptable SAR limits, imposing extremely long TRs (>100 msec), which would result in acquisition times significantly greater than a single breath-hold. In this study, the phases of the radio-frequency excitation are modified, resulting in a different pulse sequence scheme. It is shown that the new method increases sensitivity with respect to radio-frequency inhomogeneities by up to 10 times, and reduces the total duration of the pulse so that three-dimensional B(1) mapping is possible with (3) He in lungs within a single breath-hold. Computer simulations demonstrate the increase in sensitivity. Phantom results with (1) H MRI are used for validation. In vivo results are presented with hyperpolarized (3) He in human lungs at 1.5T.


Asunto(s)
Algoritmos , Helio , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Pulmón/anatomía & histología , Imagen por Resonancia Magnética/métodos , Medios de Contraste , Humanos , Isótopos , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
J Anim Ecol ; 80(6): 1123-33, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21644980

RESUMEN

1. Individual foraging behaviour defines the use of resources by a given population and its variation in different ways such as, for example, unpredictable interactions between taxon-biased and size-biased selection. Here we investigated how the environmental availability of prey and individual specialization, for both prey taxa and prey size, shape niche variation across generations in the grasshopper-hunting digger wasp Stizus continuus. 2. The population of S. continuus expressed selective predation, females mainly hunting species encountered on large bushes; diet changed across generations, due more to size increase in potential prey than to changes in the orthopteran community. 3. Individual females of both generations weakly overlapped the size and taxa of prey, and the niche width of the second generation increased for both prey size and taxa. 4. The greater variance in prey size in the environment accounted for the enlarged prey size niche of the second generation, but the load-lifting constraints of the wasps maintained individual prey size specialization constant. In contrast, the enlarged prey taxon niche paralleled a smaller overlap of diets between wasps in the second generation. 5. Increased niche width in the S. continuus population was thus achieved in two ways. Regarding prey size, all individuals shifted towards the use of the full set of available resources (parallel release). For prey taxa, according to the classical niche variation hypothesis, individuals diverged to minimize resource use overlap and perhaps intraspecific competition. These two mechanisms were observed for the first time simultaneously in a single predator population.


Asunto(s)
Saltamontes/anatomía & histología , Conducta Predatoria , Avispas/fisiología , Animales , Tamaño Corporal , Ambiente , Femenino , Masculino , Comportamiento de Nidificación , Estaciones del Año , España , Especificidad de la Especie , Avispas/anatomía & histología
6.
Theriogenology ; 167: 120-125, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33813052

RESUMEN

Identification of factors associated with the quality and quantity of colostrum production has always been a major challenge in cattle industry. In purebred double-muscled Belgian Blue (BB) cows, parturition is mainly performed by elective caesarean section (CS; >90%). However, the CS itself may influence colostrum production characteristics. The present study aimed to evaluate the impact of maternal and newborn calf factors and the duration of the procedure of CS on the quality and quantity of colostrum production in BB cows. The dataset includes 551 records of cow-calf pairs that were presented for an elective CS at the Ghent University veterinary clinic between 2017 and 2019. The quality (measured via a colostrum densimeter) and the quantity (measured via a standard volume scale) of colostrum were measured within 30 min after the end of the CS. Fixed effects were fitted in mixed linear regression models to test for their potential association with colostrum quality (specific gravity; SG) and quantity (liters), and generalized mixed-effects models were constructed to test the associations of fixed effects with the optimal colostrum production index (yes vs no) based on an adequate supply of both colostrum quality and quantity. The fixed effects tested were parity, the gender of the calf, birth weight, duration of CS (min), and season of birth. Our results show that parity (primiparity), duration of CS (longer CS), and calving season (summer) had a significantly negative impact on colostrum production. Concluding, both colostrum quality and quantity can be influenced by intrinsic and extrinsic factors (including duration of CS), which should be considered while feeding newborn calves delivered via CS.


Asunto(s)
Cesárea , Calostro , Animales , Bélgica , Bovinos , Cesárea/veterinaria , Femenino , Paridad , Parto , Embarazo
7.
Anim Reprod Sci ; 221: 106572, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32861122

RESUMEN

The increased exportation of semen and embryos of double-muscled beef breeds to tropical and developing countries makes it important to investigate the reproductive capacity of these breeds in adapting to tropical conditions. The aim of this study was to evaluate the quality of Belgian Blue semen collected after there is heat-stress (HS; as a mimic of tropical condition) compared with non-heat stressed (NHS; as their comfort zone), using practical spermatozoa staining methods such that prevail in developing countries. There was screening of semen kinetics using CASA and evaluation of their DNA-, acrosome, plasma membrane-integrity, and mitochondrial activity. For each staining technique, there was evaluation of 12 frozen-thawed semen samples from six Belgian Blue bulls collected after there were HS and NHS conditions in Belgium. Mixed linear regression models were used to assess the effects of HS for each CASA variable and staining method outcome using the replicate nested with bull as a random effect. There were differences (P < 0.05) in values when there were semen collections following HS and NHS conditions for several post-thawing kinetic variables. Furthermore, the mean percentages of DNA-, acrosome-, and plasma membrane-integrity, as well as mitochondrial activity were greater (P < 0.05) when semen was collected following NHS compared with HS conditions. Conclusively, results indicated that when there was collection of semen following HS conditions, there were detrimental effects on the viability and quality of Belgian Blue semen which is an important consideration for the semen collection, processing, and evaluation in tropical countries.


Asunto(s)
Bovinos/fisiología , Criopreservación/veterinaria , Calor , Análisis de Semen/veterinaria , Preservación de Semen/veterinaria , Animales , Masculino
8.
Sci Rep ; 9(1): 5366, 2019 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-30926867

RESUMEN

A widely held assumption in ecology is that specialists are more efficient than generalists. However, empirical evidence for this fundamental assumption is surprisingly scarce and often contradictory. Theoretically, the evolution of alternative life history strategies is underpinned by a trade-off between activity levels and survival. We investigated the consequences of specialization in a foraging context, by comparing the performance and longevity of closely related individuals in a social insect, the common wasp (Vespula vulgaris). Using radio-frequency identification technology, we monitored the lifetime foraging activity of individual wasps from three colonies kept under natural foraging conditions. Returning foragers were video-recorded as they passed the nest entrance so that their foraging load could be assessed. There were substantial differences in foraging activity and survival within and between colonies. At the colony level, foraging specialization was weak. Yet, workers within each nest demonstrated a remarkable range of foraging specialization levels (defined as the degree of overlap between individual and colony-level task allocation) and efficiencies (defined by the number of successful trips and trip duration). We found that specialist foragers were less efficient than generalist siblings within the same colony. Behavioural specialists accomplished fewer successful trips per foraging day, and their trips were typically relatively longer. Specialized foragers also showed reduced life expectancy. The mortality risk was higher for individuals spending relatively more time in the field, yet we found no link between the level of specialization and relative field exposure. Our extensive dataset of unprecedented detail provides strong empirical evidence that behavioural specialization is not associated with a better lifetime performance, on the contrary, the opposite appears true for the common wasp. We also show that the survival of genetically similar individuals can be linked to life-long differences in behaviour according to classical life-history theory predictions.


Asunto(s)
Conducta Alimentaria , Avispas/fisiología , Animales , Longevidad , Dispositivo de Identificación por Radiofrecuencia
9.
PLoS One ; 9(3): e91318, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24621588

RESUMEN

INTRODUCTION: Visual but subjective reading of longitudinal relaxation time (T1) weighted magnetic resonance images is commonly used for the detection of brain pathologies. For this non-quantitative measure, diagnostic quality depends on hardware configuration, imaging parameters, radio frequency transmission field (B1+) uniformity, as well as observer experience. Parametric quantification of the tissue T1 relaxation parameter offsets the propensity for these effects, but is typically time consuming. For this reason, this study examines the feasibility of rapid 2D T1 quantification using a variable flip angles (VFA) approach at magnetic field strengths of 1.5 Tesla, 3 Tesla, and 7 Tesla. These efforts include validation in phantom experiments and application for brain T1 mapping. METHODS: T1 quantification included simulations of the Bloch equations to correct for slice profile imperfections, and a correction for B1+. Fast gradient echo acquisitions were conducted using three adjusted flip angles for the proposed T1 quantification approach that was benchmarked against slice profile uncorrected 2D VFA and an inversion-recovery spin-echo based reference method. Brain T1 mapping was performed in six healthy subjects, one multiple sclerosis patient, and one stroke patient. RESULTS: Phantom experiments showed a mean T1 estimation error of (-63±1.5)% for slice profile uncorrected 2D VFA and (0.2±1.4)% for the proposed approach compared to the reference method. Scan time for single slice T1 mapping including B1+ mapping could be reduced to 5 seconds using an in-plane resolution of (2×2) mm2, which equals a scan time reduction of more than 99% compared to the reference method. CONCLUSION: Our results demonstrate that rapid 2D T1 quantification using a variable flip angle approach is feasible at 1.5T/3T/7T. It represents a valuable alternative for rapid T1 mapping due to the gain in speed versus conventional approaches. This progress may serve to enhance the capabilities of parametric MR based lesion detection and brain tissue characterization.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Encéfalo/citología , Encéfalo/patología , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Método de Montecarlo , Esclerosis Múltiple/diagnóstico , Esclerosis Múltiple/patología , Fantasmas de Imagen , Factores de Tiempo
10.
Invest Radiol ; 49(5): 260-70, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24651662

RESUMEN

OBJECTIVES: This study was designed to examine the feasibility of ophthalmic magnetic resonance imaging (MRI) at 7 T using a local 6-channel transmit/receive radiofrequency (RF) coil array in healthy volunteers and patients with intraocular masses. MATERIALS AND METHODS: A novel 6-element transceiver RF coil array that makes uses of loop elements and that is customized for eye imaging at 7 T is proposed. Considerations influencing the RF coil design and the characteristics of the proposed RF coil array are presented. Numerical electromagnetic field simulations were conducted to enhance the RF coil characteristics. Specific absorption rate simulations and a thorough assessment of RF power deposition were performed to meet the safety requirements. Phantom experiments were carried out to validate the electromagnetic field simulations and to assess the real performance of the proposed transceiver array. Certified approval for clinical studies was provided by a local notified body before the in vivo studies. The suitability of the RF coil to image the human eye, optical nerve, and orbit was examined in an in vivo feasibility study including (a) 3-dimensional (3D) gradient echo (GRE) imaging, (b) inversion recovery 3D GRE imaging, and (c) 2D T2-weighted fast spin-echo imaging. For this purpose, healthy adult volunteers (n = 17; mean age, 34 ± 11 years) and patients with intraocular masses (uveal melanoma, n = 5; mean age, 57 ± 6 years) were investigated. RESULTS: All subjects tolerated all examinations well with no relevant adverse events. The 6-channel coil array supports high-resolution 3D GRE imaging with a spatial resolution as good as 0.2 × 0.2 × 1.0 mm, which facilitates the depiction of anatomical details of the eye. Rather, uniform signal intensity across the eye was found. A mean signal-to-noise ratio of approximately 35 was found for the lens, whereas the vitreous humor showed a signal-to-noise ratio of approximately 30. The lens-vitreous humor contrast-to-noise ratio was 8, which allows good differentiation between the lens and the vitreous compartment. Inversion recovery prepared 3D GRE imaging using a spatial resolution of 0.4 × 0.4 × 1.0 mm was found to be feasible. T2-weighted 2D fast spin-echo imaging with the proposed RF coil afforded a spatial resolution of 0.25 × 0.25 × 0.7 mm. CONCLUSIONS: This work provides valuable information on the feasibility of ophthalmic MRI at 7 T using a dedicated 6-channel transceiver coil array that supports the acquisition of high-contrast, high-spatial resolution images in healthy volunteers and patients with intraocular masses. The results underscore the challenges of ocular imaging at 7 T and demonstrate that these issues can be offset by using tailored RF coil hardware. The benefits of such improvements would be in positive alignment with explorations that are designed to examine the potential of MRI for the assessment of spatial arrangements of the eye segments and their masses with the ultimate goal to provide imaging means for guiding treatment decisions in ophthalmological diseases.


Asunto(s)
Neoplasias del Ojo/diagnóstico , Ojo/patología , Imagen por Resonancia Magnética/instrumentación , Adulto , Anciano , Diseño de Equipo , Ojo/anatomía & histología , Estudios de Factibilidad , Femenino , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Valores de Referencia , Relación Señal-Ruido , Adulto Joven
11.
PLoS One ; 8(3): e57982, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23472127

RESUMEN

Knowledge of the transmission field (B1(+)) of radio-frequency coils is crucial for high field (B0  = 3.0 T) and ultrahigh field (B0 ≥7.0 T) magnetic resonance applications to overcome constraints dictated by electrodynamics in the short wavelength regime with the ultimate goal to improve the image quality. For this purpose B1(+) mapping methods are used, which are commonly magnitude-based. In this study an analysis of five phase-based methods for three-dimensional mapping of the B1(+) field is presented. The five methods are implemented in a 3D gradient-echo technique. Each method makes use of different RF-pulses (composite or off-resonance pulses) to encode the effective intensity of the B1(+) field into the phase of the magnetization. The different RF-pulses result in different trajectories of the magnetization, different use of the transverse magnetization and different sensitivities to B1(+) inhomogeneities and frequency offsets, as demonstrated by numerical simulations. The characterization of the five methods also includes phantom experiments and in vivo studies of the human brain at 3.0 T and at 7.0 T. It is shown how the characteristics of each method affect the quality of the B1(+) maps. Implications for in vivo B1(+) mapping at 3.0 T and 7.0 T are discussed.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Algoritmos , Encéfalo/patología , Mapeo Encefálico/métodos , Simulación por Computador , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Modelos Teóricos , Fantasmas de Imagen
12.
PLoS One ; 8(4): e61661, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23613896

RESUMEN

This work demonstrates the feasibility of a hybrid radiofrequency (RF) applicator that supports magnetic resonance (MR) imaging and MR controlled targeted RF heating at ultrahigh magnetic fields (B0≥7.0T). For this purpose a virtual and an experimental configuration of an 8-channel transmit/receive (TX/RX) hybrid RF applicator was designed. For TX/RX bow tie antenna electric dipoles were employed. Electromagnetic field simulations (EMF) were performed to study RF heating versus RF wavelength (frequency range: 64 MHz (1.5T) to 600 MHz (14.0T)). The experimental version of the applicator was implemented at B0 = 7.0T. The applicators feasibility for targeted RF heating was evaluated in EMF simulations and in phantom studies. Temperature co-simulations were conducted in phantoms and in a human voxel model. Our results demonstrate that higher frequencies afford a reduction in the size of specific absorption rate (SAR) hotspots. At 7T (298 MHz) the hybrid applicator yielded a 50% iso-contour SAR (iso-SAR-50%) hotspot with a diameter of 43 mm. At 600 MHz an iso-SAR-50% hotspot of 26 mm in diameter was observed. RF power deposition per RF input power was found to increase with B0 which makes targeted RF heating more efficient at higher frequencies. The applicator was capable of generating deep-seated temperature hotspots in phantoms. The feasibility of 2D steering of a SAR/temperature hotspot to a target location was demonstrated by the induction of a focal temperature increase (ΔT = 8.1 K) in an off-center region of the phantom. Temperature simulations in the human brain performed at 298 MHz showed a maximum temperature increase to 48.6C for a deep-seated hotspot in the brain with a size of (19×23×32)mm(3) iso-temperature-90%. The hybrid applicator provided imaging capabilities that facilitate high spatial resolution brain MRI. To conclude, this study outlines the technical underpinnings and demonstrates the basic feasibility of an 8-channel hybrid TX/RX applicator that supports MR imaging, MR thermometry and targeted RF heating in one device.


Asunto(s)
Campos Electromagnéticos , Hipertermia Inducida/instrumentación , Imagen por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Ondas de Radio , Diseño de Equipo , Estudios de Factibilidad , Humanos
13.
J Magn Reson ; 229: 208-22, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23290625

RESUMEN

A growing number of reports eloquently speak about explorations into cardiac magnetic resonance (CMR) at ultrahigh magnetic fields (B0≥7.0 T). Realizing the progress, promises and challenges of ultrahigh field (UHF) CMR this perspective outlines current trends in enabling MR technology tailored for cardiac MR in the short wavelength regime. For this purpose many channel radiofrequency (RF) technology concepts are outlined. Basic principles of mapping and shimming of transmission fields including RF power deposition considerations are presented. Explorations motivated by the safe operation of UHF-CMR even in the presence of conductive implants are described together with the physics, numerical simulations and experiments, all of which detailing antenna effects and RF heating induced by intracoronary stents at 7.0 T. Early applications of CMR at 7.0 T and their clinical implications for explorations into cardiovascular diseases are explored including assessment of cardiac function, myocardial tissue characterization, MR angiography of large and small vessels as well as heteronuclear MR of the heart and the skin. A concluding section ventures a glance beyond the horizon and explores future directions. The goal here is not to be comprehensive but to inspire the biomedical and diagnostic imaging communities to throw further weight behind the solution of the many remaining unsolved problems and technical obstacles of UHF-CMR with the goal to transfer MR physics driven methodological advancements into extra clinical value.


Asunto(s)
Campos Electromagnéticos , Corazón/anatomía & histología , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Miocardio/patología , Algoritmos , Animales , Vasos Coronarios/patología , Corazón/fisiología , Humanos , Imagen por Resonancia Magnética/tendencias , Física , Ondas de Radio , Stents
14.
PLoS One ; 7(11): e49963, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23185498

RESUMEN

The sensitivity gain of ultrahigh field Magnetic Resonance (UHF-MR) holds the promise to enhance spatial and temporal resolution. Such improvements could be beneficial for cardiovascular MR. However, intracoronary stents used for treatment of coronary artery disease are currently considered to be contra-indications for UHF-MR. The antenna effect induced by a stent together with RF wavelength shortening could increase local radiofrequency (RF) power deposition at 7.0 T and bears the potential to induce local heating, which might cause tissue damage. Realizing these constraints, this work examines RF heating effects of stents using electro-magnetic field (EMF) simulations and phantoms with properties that mimic myocardium. For this purpose, RF power deposition that exceeds the clinical limits was induced by a dedicated birdcage coil. Fiber optic probes and MR thermometry were applied for temperature monitoring using agarose phantoms containing copper tubes or coronary stents. The results demonstrate an agreement between RF heating induced temperature changes derived from EMF simulations versus MR thermometry. The birdcage coil tailored for RF heating was capable of irradiating power exceeding the specific-absorption rate (SAR) limits defined by the IEC guidelines by a factor of three. This setup afforded RF induced temperature changes up to +27 K in a reference phantom. The maximum extra temperature increase, induced by a copper tube or a coronary stent was less than 3 K. The coronary stents examined showed an RF heating behavior similar to a copper tube. Our results suggest that, if IEC guidelines for local/global SAR are followed, the extra RF heating induced in myocardial tissue by stents may not be significant versus the baseline heating induced by the energy deposited by a tailored cardiac transmit RF coil at 7.0 T, and may be smaller if not insignificant than the extra RF heating observed under the circumstances used in this study.


Asunto(s)
Espectroscopía de Resonancia Magnética , Ondas de Radio , Stents , Enfermedad Coronaria/terapia , Campos Electromagnéticos , Tecnología de Fibra Óptica , Calefacción , Humanos , Dispositivo de Identificación por Radiofrecuencia , Temperatura
15.
Hypertension ; 59(1): 167-72, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22146510

RESUMEN

Hypertension is linked to disturbed total-body sodium (Na(+)) regulation; however, measuring Na(+) disposition in the body is difficult. We implemented (23)Na magnetic resonance spectroscopy ((23)Na-MR) and imaging technique ((23)Na-MRI) at 9.4T for animals and 3T for humans to quantify Na(+) content in skeletal muscle and skin. We compared (23)Na-MRI data with actual tissue Na(+) content measured by chemical analysis in animal and human tissue. We then quantified tissue Na(+) content in normal humans and in patients with primary aldosteronism. We found a 29% increase in muscle Na(+) content in patients with aldosteronism compared with normal women and men. This tissue Na(+) was mobilized after successful treatment without accompanying weight loss. We suggest that, after further refinements, this tool could facilitate understanding the relationships between Na(+) accumulation and hypertension. Furthermore, with additional technical advances, a future clinical use may be possible.


Asunto(s)
Hiperaldosteronismo/diagnóstico , Hiperaldosteronismo/metabolismo , Hipertensión/diagnóstico , Hipertensión/metabolismo , Espectroscopía de Resonancia Magnética/métodos , Sodio/metabolismo , Animales , Femenino , Humanos , Masculino , Ratones , Músculo Esquelético/metabolismo , Ratas Sprague-Dawley , Piel/metabolismo , Isótopos de Sodio , Equilibrio Hidroelectrolítico/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA