RESUMEN
BACKGROUND: Brugada syndrome poses significant challenges in terms of risk stratification and management, particularly for asymptomatic patients who comprise the majority of individuals exhibiting Brugada ECG pattern (BrECG). The aim of this study was to evaluate the long-term prognosis of a large cohort of asymptomatic patients with BrECG. METHODS: Asymptomatic patients with BrECG (1149) were consecutively collected from 2 Italian centers and followed-up at least annually for 2 to 22 years. For the 539 asymptomatic patients (men, 433 [80%]; mean age, 46±13 years) with spontaneous type 1 documented on baseline ECG (87%) or 12-lead 24-hour Holter monitoring (13%), an electrophysiologic study (EPS) was proposed; for the 610 patients with drug-induced-only type 1 (men, 420 [69%]; mean age, 44±14 years), multiple ECGs and 12-lead Holter were advised in order to detect the occurrence of a spontaneous type-1 BrECG. Arrhythmic events were defined as sudden death or documented ventricular fibrillation or tachycardia. RESULTS: Median follow-up was 6 (4-9) years. Seventeen (1.5%) arrhythmic events occurred in the overall asymptomatic population (corresponding to an event-rate of 0.2% per year), including 16 of 539 (0.4% per year) in patients with spontaneous type-1 BrECG and 1 of 610 in those with drug-induced type-1 BrECG (0.03% per year; P<0.001). EPS was performed in 339 (63%) patients with spontaneous type-1 BrECG. Patients with spontaneous type-1 BrECG and positive EPS had significantly higher event rates than patients with negative EPS (7 of 103 [0.7% per year] versus 4 of 236 [0.2% per year]; P=0.025). Among 200 patients who declined EPS, 5 events (0.4% per year) occurred. There was 1 device-related death. CONCLUSIONS: The entire population of asymptomatic patients with BrECG exhibits a relatively low event rate per year, which is important in view of the long life expectancy of these young patients. The presence of spontaneous type-1 BrECG associated with positive EPS identifies a subgroup at higher risk. Asymptomatic patients with drug-induced-only BrECG have a minimal arrhythmic risk, but ongoing follow-up with 12-lead Holter monitoring is recommended to detect the appearance of spontaneous type-1 BrECG pattern.
Asunto(s)
Síndrome de Brugada , Masculino , Humanos , Adulto , Persona de Mediana Edad , Estudios Prospectivos , Pronóstico , Arritmias Cardíacas/complicaciones , Electrocardiografía , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Medición de RiesgoRESUMEN
Dupilumab is a biologic, acting on IL-4 and IL-13 pathways. Dupilumab has a pediatric indication for treating severe asthma and atopic dermatitis. We report a pediatric case concerning paucisymptomatic, transient, and self-resolving hyperthyroidism. The updated literature includes the case of an adult patient who reported with hyperthyroidism, which was transient and self-resolving. Despite that these cases were transient and self-resolving, we would suggest that thyroid function assessment could be included in the follow-up of patients treated with Dupilumab. Dupilumab discontinuation is not required pending endocrinological assessment, mainly if there is an optimal clinical response to the biologic.
Asunto(s)
Asma , Productos Biológicos , Dermatitis Atópica , Hipersensibilidad , Hipertiroidismo , Adulto , Humanos , Adolescente , Niño , Dermatitis Atópica/tratamiento farmacológico , Anticuerpos Monoclonales/uso terapéutico , Asma/tratamiento farmacológico , Hipersensibilidad/tratamiento farmacológico , Hipertiroidismo/tratamiento farmacológico , Índice de Severidad de la Enfermedad , Productos Biológicos/uso terapéutico , Resultado del TratamientoRESUMEN
Introduction: Gender medicine is an innovative medical approach that studies how some biological variables are influenced by the male or female sex and gender. This issue is under debate because it characterizes the impact of tailored or individual medicine. In this scenario, the aim of this study is to study the correlation between heavy metal exposure and pathologies of neurodevelopment, according to the sex of newborns. In particular, this is an observational study under the name of the Neurosviluppo Project, involving 217 mother-child couples. Material and methods: The correlation with phenotype small for gestational age and congenital malformations were studied, but above all we focused on the pattern of placental permeability to heavy metals. Results: Our results are specifically related to foetal medicine and investigate the impact of foetal sex in transplacental metal exposure. Our results did not show any significant differences related to foetal sex in terms of congenital malformations or the other variables taken into consideration. However, because these conclusions are the first related to the gender medicine in transplacental foetal medicine, they could be a marked background for further studies. Conclusions: Considering the lack of data in literature regarding foetal sexual medicine and transplacental exposure, these study results are pioneering in terms of sexual foetal medicine. Possibly in the future, studies regarding the correlation between foetal sex and obstetrics outcomes will be performed.
RESUMEN
Subfertility and infertility are common problems among couples of reproductive age, and they increasingly require the use of assisted reproductive techniques (ART). Understandably, doubts about the safety of such methods are increasing among future parents. The purpose of this review is to analyse the real impact of ART, such as in vitro fertilisation (IVF) and intracytoplasmic sperm injection (ICSI), on the health of the unborn baby; in particular, this work is focussed on the problems related to the neuro-psycho-motor area. Twenty-four studies were reviewed and outcomes investigated were: risk of the onset of neurodevelopmental diseases, worsening of school cognitive performance and risk of developing infantile cerebral palsy (CP) or neurological sequelae. For the first two outcomes, we did not find a correlation with ART; nevertheless, the results of the included studies about risk of CP are discordant and influenced by various confounding factors, such as pre-term birth and multiple pregnancies.IMPACT STATEMENTWhat is already known on this subject? Assisted reproductive techniques (ART) are the main answer for achieving pregnancy in infertile couples. However, a wide number of studies have tried to focus on possible different outcomes in terms of maternal and foetal/new-born health. Regarding this scenario, a peculiar importance is given to diseases affecting the neuro-psycho-motor area of the new-born. Since this group of detrimental pathologies could heavily affect the new-born's quality of life and require costly social facilities, different studies have tried to focus on possible outcomes after ART.What do the results of this study add? This manuscript provides a review of the literature regarding ART procedures and neuro-psycho-motor implication. A review is strongly required due to the importance of collecting evidence from studies with different methodologies.What are the implications of these findings for clinical practice and/or further research? This manuscript provides evidence about the need for wider and more congruent studies regarding neurodevelopment disorders in new-borns after ART procedures. Data are prone to suggest a slight correlation, but several confounding factors can heavily hamper the possibility to draw a firm conclusion about the topic.
Asunto(s)
Infertilidad , Calidad de Vida , Embarazo , Femenino , Masculino , Humanos , Recién Nacido , Semen , Técnicas Reproductivas Asistidas/efectos adversos , Fertilización In Vitro , Infertilidad/etiología , Infertilidad/terapiaRESUMEN
In recent years, the growing use of ART (assisted reproductive techniques) has led to a progressive improvement of protocols; embryo freezing is certainly one of the most important innovations. This technique is selectively offered as a tailored approach to reduce the incidence of multiple pregnancies and, most importantly, to lower the risk of developing ovarian hyperstimulation syndrome when used in conjunction with an ovulation-triggering GnRH antagonist. The increase in transfer cycles with frozen embryos made it possible to study the effects of the technique in children thus conceived. Particularly noteworthy is the increase in macrosomal and LGA (large for gestational age) newborns, in addition to a decrease in SGA (small for gestational age) and LBW (low birth weight) newborns. The authors aimed to outline a broad-ranging narrative review by summarizing and elaborating on the most important evidence regarding the neonatal outcome of children born from frozen embryos and provide information on the medium and long-term follow- up of these children. However, given the relatively recent large-scale implementation of such techniques, further studies are needed to provide more conclusive evidence on outcomes and implications.
Asunto(s)
Criopreservación , Transferencia de Embrión , Niño , Transferencia de Embrión/efectos adversos , Transferencia de Embrión/métodos , Femenino , Estudios de Seguimiento , Hormona Liberadora de Gonadotropina , Humanos , Recién Nacido , Embarazo , Técnicas Reproductivas AsistidasRESUMEN
INTRODUCTION: Radiofrequency transcatheter ablation (RFCA) for atrial fibrillation (AF) in patients with hypertrophic cardiomyopathy (HCM) has been proven feasible. However, the long-term results of RFCA and its impact on clinical course of HCM are unknown. The aim of this study was to analyse clinical outcomes and long-term efficacy of RFCA in a multicentre cohort of patients with HCM and concomitant AF. METHODS: Patients with HCM and AF consecutively undergoing RFCA were included. Ablation failure was defined as recurrence of AF, atrial tachycardia, or flutter lasting more than 3 min and occurring after the blanking period. RESULTS: Overall, 116 patients with symptomatic AF refractory to antiarrhythmic drugs were included. Over a median follow-up of 6.0 years (interquartile range: 3.0-8.9 years) recurrence rate after a single RFCA was 32.3 per 100 patient/years with 26% of patients free from AF relapses at 6-year follow-up. Among patients experiencing AF recurrence, 51 (66%) underwent at least one redo-procedure. The overall recurrence rate considering redo-procedures was 12.6 per 100 patients/years with 53% of patients free from AF relapses at 6 years. At last follow-up, with an average of 1.6 procedures, 67 (61%) patients were in sinus rhythm (SR). Patients remaining in SR showed better functional status compared with those experiencing arrhythmic recurrences (NYHA Class 1.6 ± 0.1 vs. 2.0 ± 0.1, p = .009). CONCLUSIONS: RFCA of AF in HCM patients is an effective and safe strategy favoring long-term SR maintenance, reduction of atrial arrhythmic events, and improved functional status. However, most patients need repeat procedures and continuation of antiarrhythmic drugs.
Asunto(s)
Fibrilación Atrial , Cardiomiopatía Hipertrófica , Ablación por Catéter , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/cirugía , Ablación por Catéter/efectos adversos , Humanos , Recurrencia , Resultado del TratamientoRESUMEN
BACKGROUND: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have recently emerged as a viable real-time indicator of tissue characteristics and durability of the lesions created. We report the outcomes of acute and long-term clinical evaluation of the new DirectSense algorithm in AF ablation. METHODS: Consecutive patients undergoing AF ablation were included in the CHARISMA registry. RF delivery was guided by the DirectSense algorithm, which records the magnitude and time-course of the impedance drop. The ablation endpoint was pulmonary vein isolation (PVI), as assessed by the entrance and exit block. RESULTS: 3556 point-by-point first-pass RF applications of >10 s duration were analyzed in 153 patients (mean age=59 ± 10 years, 70% men, 61% paroxysmal AF, 39% persistent AF). The mean baseline LI was 105 ± 15 Ω before ablation and 92 ± 12 Ω after ablation (p < .0001). Both absolute drops in LI and the time to LI drop (LI drop/τ) were greater at successful ablation sites (n = 3122, 88%) than at ineffective ablation sites (n = 434, 12%) (14 ± 8 Ω vs 6 ± 4 Ω, p < .0001 for LI; 0.73 [0.41-1.25] Ω/s vs. 0.35[0.22-0.59 Ω/s, p < .0001 for LI drop/τ). No major complications occurred during or after the procedures. All PVs had been successfully isolated. During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/atrial tachycardia recurrence after the 90-day blanking period. CONCLUSION: The magnitude and time-course of the LI drop during RF delivery were associated with effective lesion formation. This ablation strategy for PVI guided by LI technology proved safe and effective and resulted in a very low rate of AF recurrence over 1-year follow-up.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Algoritmos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Impedancia Eléctrica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Recurrencia , Resultado del TratamientoRESUMEN
AIMS: Ablation index (AI) is a marker of lesion quality during catheter ablation that incorporates contact force, time, and power in a weighted formula. This index was originally developed for pulmonary vein isolation as well as other left atrial procedures. The aim of our study is to evaluate the feasibility and efficacy of the AI for the ablation of the cavotricuspid isthmus (CTI) in patients presenting with typical atrial flutter (AFL). METHODS AND RESULTS: This prospective multicentre non-randomized study enrolled 412 consecutive patients with typical AFL undergoing AI-guided cavotricuspid isthmus ablation. The procedure was performed targeting an AI of 500 and an inter-lesion distance measurement of ≤6 mm. The primary endpoints were CTI 'first-pass' block and persistent block after a 20-min waiting time. Secondary endpoints included procedural and radiofrequency duration and fluoroscopic time. A total of 412 consecutive patients were enrolled in 31 centres (mean age 64.9 ± 9.8; 72.1% males and 27.7% with structural heart disease). The CTI bidirectional 'first-pass' block was reached in 355 patients (88.3%), whereas CTI block at the end of the waiting time was achieved in 405 patients (98.3%). Mean procedural, radiofrequency, and fluoroscopic time were 56.5 ± 28.1, 7.8 ± 4.8, and 1.9 ± 4.8 min, respectively. There were no major procedural complications. There was no significant inter-operator variability in the ability to achieve any of the primary endpoints. CONCLUSION: AI-guided ablation with an inter-lesion distance ≤6 mm represents an effective, safe, and highly reproducible strategy to achieve bidirectional block in the treatment of typical AFL.
Asunto(s)
Aleteo Atrial , Ablación por Catéter , Anciano , Aleteo Atrial/diagnóstico , Aleteo Atrial/cirugía , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugíaRESUMEN
BACKGROUND: Ablation index (AI) is a new lesion quality marker that has been demonstrated to allow a high single-procedure arrhythmia-free survival in single-center studies. This prospective, multi-center study was designed to evaluate the reproducibility of pulmonary vein (PV) isolation guided by the AI. METHODS: A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV isolation and were divided in four study groups according to operator's preference in choosing the ablation catheter (a contact force (ST) or contact force surround flow (STSF) catheter) and the AI setting (330-450 or 380-500 at anterior wall or posterior wall, respectively). RESULTS: At 12 months a high rate of freedom from AF recurrences was observed in patients with both paroxysmal and persistent AF (91% vs 83.3%; P = .039). There was no difference in the rate of AF recurrence among the four study groups (4.5% in group ST330-450, 12.2% in group ST 380-500, 14.9% in group STSF330-450, 9.4% in group STSF380-500; P = .083). Recurrence was also similar between patients treated with a ST (8%) or STSF catheter (12.1%; P = .2), and within patients targeting an AI settings of 330 to 450 (10.9%) or 380 to 500 (10.3%; P = .64). In patients with paroxysmal AF, there was no difference (P = .12) in the 1-year freedom from AF recurrence among 14 operators that performed ≥10 ablation procedure. CONCLUSIONS: An ablation protocol respecting strict criteria for contiguity and quality lesion resulted in high rate of 1-year freedom from AF recurrence, irrespective of the ablation catheters, AI settings, and operator.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Estudios Prospectivos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Sistema de Registros , Reproducibilidad de los Resultados , Resultado del TratamientoRESUMEN
BACKGROUND: Atrial fibrillation (AF) ablation outcome is still operator dependent. Ablation Index (AI) is a new lesion quality marker that has been demonstrated to allow acute durable pulmonary vein (PV) isolation followed by a high single-procedure arrhythmia-free survival. This prospective, multicenter study was designed to evaluate the reproducibility of acute PV isolation guided by the AI. METHODS: A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV encircling and were divided in four study groups according to operator preference in choosing the ablation catheter (a contact force [ST] or contact force surround flow [STSF] catheter) and the AI setting (330 at posterior and 450 at anterior wall or 380 at posterior and 500 at anterior wall). Radiofrequency was delivered targeting interlesion distance ≤6 mm. RESULTS: The rate of first-pass PV isolation (ST330 90 ± 16%, ST380 87 ± 19%, STSF330 90 ± 17%, STSF380 91 ± 15%, P = .585) was similar among the four study groups, whereas procedure (ST330 129 ± 44 minutes, ST380 144 ± 44 minutes, STSF330 120 ± 72 minutes, STSF380 125 ± 73 minutes, P < .001) and fluoroscopy time (ST330 542 ± 285 seconds, ST380 540 ± 416 seconds, STSF330 257 ± 356 seconds, STSF380 379 ± 454 seconds, P < 0.001) significantly differed. The difference in the rate of first-pass isolation was not statistical different (P = .06) among the 12 operators that performed at least 15 procedures. CONCLUSIONS: An ablation protocol respecting strict criteria for contiguity and quality lesion results in high and comparable rate of acute PV isolation among operator performing ablation with different catheters, AI settings, procedure, and fluoroscopy times.
Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros , Reproducibilidad de los ResultadosRESUMEN
Aims: Atrial fibrillation (AF) transcatheter ablation is a safe and effective procedure. However, outcome over 10 years of follow-up has never been reported. The aim of this study is to assess outcome, describe predictors of recurrences, and report on quality of life (QoL) the decade after an AF ablation. Methods and results: Patients referred for AF ablation in a single high volume centre from June 2004 to June 2006 were enrolled and followed in a prospective fashion by yearly clinical assessment and Holter monitoring. Among 255 patients (42.7% paroxysmal AF, 77% males, after a follow-up of 125 ± 7 months), 132 (52%) were arrhythmia-free including (58, 32% after a single procedure) while 27 (10%) progressed to permanent AF. At multivariate analysis, a greater left atrium antero-posterior diameter (HR 1.05 95% CI 1.02-1.09, P = 0.02) related to arrhythmic recurrences, while no increase in blood pressure (HR 0.06 95% CI 0.02-0.20, P = 0.01), BMI (HR 0.06 95% CI 0.02-0.09, P < 0.001), and fasting glucose (HR 0.58 95% CI 0.36-0.92, P = 0.02) during follow-up were protective for arrhythmic recurrences. Overall QoL improved significantly, significantly related to the absence of recurrences, arrhythmic burden reduction and blood pressure, and BMI control (P < 0.001). Conclusion: The outcome of AF ablation over more than 10 years is characterized by a low incidence of progression towards permanent AF. Greater LA anteroposterior diameter related to arrhythmic recurrences, while blood pressure, BMI, and fasting blood glucose control emerged as predictors of sinus rhythm maintenance. Eventually, QoL improved significantly over the follow-up.
Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Sistema de Conducción Cardíaco/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Electrocardiografía Ambulatoria , Femenino , Estudios de Seguimiento , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Hospitales de Alto Volumen , Humanos , Masculino , Persona de Mediana Edad , Supervivencia sin Progresión , Calidad de Vida , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del TratamientoRESUMEN
INTRODUCTION: Pulmonary vein (PV) isolation is the cornerstone of catheter ablation in patients with atrial fibrillation (AF). Surround flow and contact force (CF) measurement capabilities might enhance procedure efficacy and safety. We report on the safety and midterm efficacy of a novel ablation catheter for PV isolation in patients with AF. METHODS AND RESULTS: Two hundred thirty-three consecutive patients (57 ± 11 years, 76% males, 51% with structural heart disease), referred for paroxysmal (157) or persistent (76) AF, underwent PV isolation by a surround flow catheter with CF measurement capability in four centers. Ablation was guided by electroanatomic mapping allowing radiofrequency (RF) energy delivery in the antral region aiming at PV isolation. Mean overall procedure time was 100 ± 42 minutes with a mean fluoroscopy time of 6 ± 5 minutes. Mean ablation time was 31±15 minutes; 99% of the targeted veins were isolated. The mean CF value during ablation was 13 ± 4 g. Intraprocedural early (30 minutes) PV reconnection occurred in 12% PVs, and all PVs were effectively reisolated. One pericardial effusion and five groin hematomas were reported. During a mean follow-up of 12 ± 6 months, 30 (12.9%) (10% paroxysmal AF vs. 18% persistent AF, P = 0.07) patients had an atrial arrhythmias recurrence. CONCLUSIONS: In this multicenter registry, RF ablation using a new surround flow catheter, with CF sensor, resulted as feasible, achieving a high rate of isolated PVs. Procedural and fluoroscopy times and success rates were comparable with other techniques with a low complication rate.
Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Sistema de Registros , Adulto , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Ablación por Catéter/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento , Adulto JovenRESUMEN
BACKGROUND: This meta-analysis aims to assess the impact of a voltage-guided substrate modification by targeting low-voltage area (LVA) in addition to pulmonary vein isolation (PVI) in patients undergoing catheter ablation for atrial fibrillation (AF). METHODS: MEDLINE/PubMed, Cochrane Library, and references reporting AF ablation and "voltage* OR substrate* OR fibrosis OR fibrotic area*" were screened and studies included if matching inclusion and exclusion criteria. RESULTS: Six studies were included. Patients enrolled were 885 (517 in the study group and 368 in the control group). Median age was 60 years; 92% had nonparoxysmal AF. At a mean follow-up of 17 months, 70% of patients in the study group vs. 43% in the control group were free from AF/atrial tachycardia (AT) recurrences (odds ratio [OR] = 3.41, 95% confidence interval [CI] 2.22-5.24). LVA ablation in addition to PVI was more effective than PVI alone and PVI + conventional wide empirical ablation (70% vs. 43%, OR = 3.41, 95% CI 2.22-5.24), without increasing the adverse event rate (2.5% vs. 6%, OR = 0.43, 95% CI 0.15-1.26). Compared to PVI + conventional wide empirical ablation, LVA ablation reduced the occurrence of postablation AT (14% vs. 46%, OR = 0.16, 95% CI 0.07-0.37), procedure time (176 min vs. 220 min, OR = 0.36, 95% CI 0.24-0.56), fluoroscopy time (25 min vs. 31 min, OR = 0.22, 95% CI 0.12-0.39), and radiofrequency time (55 min vs. 90 min, OR = 0.49, 95% CI 0.27-0.90). CONCLUSIONS: A voltage-guided substrate modification by targeting LVA in addition to PVI is more effective, safer, and holds a lower proarrhythmic potential than conventional ablation approaches. Further randomized studies are necessary to confirm these findings.
Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/estadística & datos numéricos , Ablación por Catéter/estadística & datos numéricos , Complicaciones Posoperatorias/epidemiología , Cirugía Asistida por Computador/estadística & datos numéricos , Fibrilación Atrial/diagnóstico , Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter/métodos , Femenino , Atrios Cardíacos/cirugía , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias/prevención & control , Prevalencia , Factores de Riesgo , Cirugía Asistida por Computador/métodos , Resultado del TratamientoRESUMEN
AIMS: Aim of this study is to evaluate the impact of antiarrhythmic drugs (AADs) administration for at least one month before ECV on the acute and long term success rate of the procedure. METHODS: 1313 consecutive persistent AF patients were enrolled in 3 different centers (Turin, Asti and Avellino): 692 patients received AADs before and after ECV (group A), 621 patients were treated only after the procedure, at discharge (group B). Primary end point was the restoration and maintenance of sinus rhythm acutely and at a long-term follow up. RESULTS: Acute ECV success was higher in group A compared with group B (99% vs. 88%, p=0.0001) and a fewer number of shock attempts were administered (1.15±0.42 vs. 1.27±0.53 p<0.0001). Moreover group A maintained SR more often than group B at one month (99% vs. 89%, log-rank p<0.0001), at one year (55% vs. 48% log-rank p=0.01) and at the end of follow up (mean 2.7±2.1years, 45% vs. 29%, log-rank p<0.0001). At multivariate analysis AADs premedication was the strongest independent predictor of acute and long-term ECV success (respectively p<0.0001 OR 10.71 CI 5.10-22.50 and p=0.004, OR 1.50 CI 1.14-1.97). At sensitivity analysis no differences were found between ADDs in terms of acute success improvement (p=0.605), number of shock attempts (p=0.853) and long term SR maintenance (log-rank p=0.480). CONCLUSIONS: AADs administration for at least 4weeks before the ECV in persistent AF increases significantly the acute success rate and this result was maintained over a long-term follow-up.
Asunto(s)
Antiarrítmicos/administración & dosificación , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/epidemiología , Electrocardiografía/efectos de los fármacos , Premedicación/métodos , Premedicación/estadística & datos numéricos , Anciano , Fibrilación Atrial/diagnóstico , Enfermedad Crónica , Electrocardiografía/estadística & datos numéricos , Femenino , Humanos , Italia/epidemiología , Estudios Longitudinales , Masculino , Prevalencia , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Sensibilidad y Especificidad , Resultado del TratamientoRESUMEN
BACKGROUND AND PURPOSE: Endovascular procedures, including atrial fibrillation transcatheter ablation, may cause microembolization of brain arteries. Microemboli often cause small sized and clinically silent cerebral ischemias (SCI). These lesions are clearly visible on early postoperative magnetic resonance diffusion-weighted images. We analyzed SCI distribution in a population of patients submitted to atrial fibrillation transcatheter ablation. METHODS: Seventy-eight of 927 consecutive patients submitted to atrial fibrillation transcatheter ablation were found positive for acute SCI on a postoperative magnetic resonance. SCI were identified and marked, and their coordinates were transformed from native space into the International Consortium for Brain Mapping/Montreal Neurological Institute space. We then computed the voxel-wise probability distribution map of the SCI using the activation likelihood estimation approach. RESULTS: SCI were more commonly found in the cortex. In supratentorial regions, SCI selectively involved cortical border zone between anterior, middle, and posterior cerebral arteries; in infratentorial regions, distal territory of posteroinferior cerebellar artery. Possible explanations include selective embolization, linked to the vascular anatomy of pial arteries supplying those territories, reduced clearance of emboli in a relatively hypoperfused zone, or a combination of both. This particular distribution of lesions has been reported in both animal models and in patients with microemboli of different sources. CONCLUSIONS: A selective vulnerability of cortical border zone to microemboli occurring during atrial fibrillation transcatheter ablation was observed. We hypothesize that such selectivity may apply to microemboli of different sources.
Asunto(s)
Corteza Cerebral/patología , Embolización Terapéutica/efectos adversos , Embolia Intracraneal/diagnóstico , Embolia Intracraneal/etiología , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Cateterismo Cardíaco/efectos adversos , Corteza Cerebral/irrigación sanguínea , Infarto Cerebral/diagnóstico , Infarto Cerebral/etiología , Femenino , Humanos , Masculino , Persona de Mediana EdadRESUMEN
Brain magnetic resonance imaging (MRI) has identified a high incidence of cerebral ischemia in asymptomatic patients after atrial fibrillation (AF) ablation (silent). Detection of cerebral ischemic events on MRI is based on acute hyperintense lesions on diffusion-weighted imaging. In the literature, the incidence is related to specifications of MRI and depends on the definition applied. In comparative studies, silent cerebral events (SCE, diffusion-weighted MRI [DWI] positive only) appear to be approximately 3 times more common compared to using a definition of silent cerebral lesions (SCL; without fluid attenuated inverse recovery sequence [FLAIR] positivity). Whereas the FLAIR sequence may turn positive within days after the ischemic event, SCE definition is highly sensitive for early phases of ischemic brain damage. SCE/SCL appear to represent cerebral ischemic infarcts and determine the "embolic fingerprint" of a specific ablation technology and strategy used. The optimum time point for detecting SCE is early after AF ablation (24-72 hours), whereas detection of SCL can only be performed within the first 2-7 days (due to delay of FLAIR positivity). Different technology-, procedure-, and patient-related parameters have been identified to play a role in the multifactorial genesis of SCE/SCL. In recent years, evidence has been gathered that there may be differences of SCE/SCL rates depending upon the ablation technology used, but small patient numbers and a large number of potential confounders hamper all studies. As major findings of recent studies, mode of periprocedural and intraprocedural anticoagulation has been identified as a major predictor for incidences of SCE/SCL. Whereas procedural characteristics related to higher SCE/SCL-rates may be modified, unchangeable patient-related factors should be taken into account for future individualized risk assessment. Novel ablation devices introduced into the market should be tested for their potential embolic fingerprint and refinements of ablation procedures to reduce their embolic potential should be prompted. The knowledge of "best practice" in terms of low SCE/SCL rates has prompted changes in work-flow, which have been implemented into ablation procedures using novel ablation devices. So far, no study has linked SCE/SCL to neuropsychological decline and the low number of AF-ablation-associated events needs to be weighted against the multitude of preexisting asymptomatic MRI-detected brain lesions related to the course of AF itself. Future studies are needed to evaluate if more white matter hyperintensities due to AF may be prevented by AF ablation (producing only a small number of SCE/SCL).
Asunto(s)
Fibrilación Atrial/cirugía , Isquemia Encefálica/etiología , Ablación por Catéter/efectos adversos , Embolia Intracraneal/etiología , Enfermedades Asintomáticas , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Isquemia Encefálica/diagnóstico , Consenso , Imagen de Difusión por Resonancia Magnética , Humanos , Embolia Intracraneal/diagnóstico , Valor Predictivo de las Pruebas , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: Fluoroscopic catheter ablation of cardiac arrhythmias in pediatric patients exposes the patients to the potential risk of radiation considering the sensitivity of this population and its longer life expectancy. We evaluated the feasibility, safety, and efficacy of accessory pathway (AP) ablation guided by CARTO3 electroanatomic mapping (EAM) system with both cryoenergy and radiofrequency (RF) energy in order to avoid x-ray exposure in pediatric patients. METHODS: We included 44 patients (mean age: 13.1 ± 3.3 years); nine of 44 presented concealed AP. An electrophysiological study with a three-dimensional EAM reconstruction was performed in every patient with a venous transfemoral direct right atrium approach or an arterial transfemoral retrograde approach to reach the mitral annulus. In two patients with left-sided AP, the ablation was performed via a patent foramen ovale. RESULTS: A total of 47 APs were present, left sided in 45% (21/47) of cases (15 lateral, one anterior, three posteroseptal, and two posterolateral) and right sided in 55% (26/47; one anterior, three anterolateral, one posterolateral, three lateral, five para-Hisian, 12 posteroseptal, and one anteroseptal). Ablation without the use of fluoroscopy was successfully performed in every patient (33 with RF and in 11 with cryoenergy). No complication occurred. At a mean follow-up of 16.0 ± 11.7 months, we observed seven recurrences, three of them successfully re-ablated without fluoroscopy. In one case cryoablation of a para-Hisian AP was ineffective in the long term. CONCLUSIONS: Three-dimensional EAM allowed a safe and effective fluoroless AP ablation procedure in a pediatric population both with RF and cryoenergy.
Asunto(s)
Fascículo Atrioventricular Accesorio/cirugía , Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/cirugía , Adolescente , Niño , Criocirugía , Estudios de Factibilidad , Femenino , Fluoroscopía , Humanos , Masculino , Seguridad del Paciente , Ondas de Radio , Resultado del TratamientoAsunto(s)
Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Síndrome de Brugada/complicaciones , Síndrome de Brugada/fisiopatología , Cardiología , Niño , Preescolar , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Electrocardiografía , Femenino , Fiebre/etiología , Pruebas Genéticas , Humanos , Lactante , Recién Nacido , Italia , Masculino , Canal de Sodio Activado por Voltaje NAV1.5/genética , Factores de Riesgo , Factores Sexuales , Sociedades Médicas , DeportesRESUMEN
BACKGROUND: Simultaneous multipolar ablation catheters have been proposed to simplify pulmonary vein isolation (PVI) in paroxysmal atrial fibrillation (AF). Recently, a new multipolar irrigated radiofrequency (RF) ablation catheter (nMARQ™, Biosense Webster Inc., Diamond Bar, CA, USA) combining both 3-dimensional electroanatomic mapping and multipolar open-irrigated ablation capability has been developed. Aim of our study was to assess feasibility, acute and short-term success and safety of PVI by the use of this new technology with particular regard to the incidence of postablation silent cerebral ischemia (SCI). METHODS AND RESULTS: Twenty-five patients (76% males; age 57 ± 13 years) with paroxysmal AF underwent PVI using the nMARQ™ catheter. PVI, confirmed by Lasso catheter mapping, was achieved in 100 out of 102 pulmonary veins (98%) identified, and final PVI was obtained in 24 out of 25 (96%) patients. The overall concordance between Lasso and nMARQ™ signals in demonstrating PVI was 78%. No major procedural complications occurred and no patient suffered SCI, on the basis of cerebral magnetic resonance imaging performed before and after the procedure. Following a 6-month follow-up, 17/25 (68%) patients remained free from AF without antiarrhythmic drugs. CONCLUSIONS: In our preliminary experience, PVI with nMARQ™ catheter appears to be feasible and safe, without incidence of SCI. Long-term clinical efficacy has to be evaluated in further studies.