Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Medicina (Kaunas) ; 59(6)2023 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-37374220

RESUMEN

Sex-related disparities have been recognized in incidence, pathological findings, pathophysiological mechanisms, and diagnostic pathways of non-rheumatic mitral regurgitation. Furthermore, access to treatments and outcomes for surgical and interventional therapies among women and men appears to be different. Despite this, current European and US guidelines have identified common diagnostic and therapeutic pathways that do not consider patient sex in decision-making. The aim of this review is to summarize the current evidence on sex-related differences in non-rheumatic mitral regurgitation, particularly regarding incidence, imaging modalities, surgical-derived evidence, and outcomes of transcatheter edge-to-edge repair, with the goal of informing clinicians about sex-specific challenges to consider when making treatment decisions for patients with mitral regurgitation.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Masculino , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/terapia , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Caracteres Sexuales , Cateterismo Cardíaco/métodos , Resultado del Tratamiento
2.
J Cardiovasc Electrophysiol ; 32(9): 2528-2535, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34252991

RESUMEN

INTRODUCTION: Factors influencing malignant arrhythmia onset are not fully understood. We explored the circadian periodicity of ventricular arrhythmias (VAs) in patients with implantable cardioverter and cardiac resynchronization defibrillators (ICD/CRT-D). METHODS: Time, morphology (monomorphic/polymorphic), and mode of termination (anti-tachycardia pacing [ATP] or shock) of VAs stored in a database of remote monitoring data were adjudicated. Episodes were grouped in six 4-h timeslots from 00:00 to 24:00. Circadian distributions and adjusted marginal odds ratios (ORs), with 95% confidence interval (CI), were analyzed using mixed-effect models and logit generalized estimating equations, respectively, to account for within-subject correlation of multiple episodes. RESULTS: Among 1303 VA episodes from 446 patients (63% ICD and 37% CRT-D), 120 (9%) self-extinguished, and 842 (65%) were terminated by ATP, 343 (26%) by shock. VAs clustered from 08:00 to 16:00 with 44% of episodes, as compared with 22% from 00:00 to 08:00 (p < .001) and 34% from 16:00 to 24:00 (p = .005). Episodes were more likely to be polymorphic at night with an adjusted marginal OR of 1.66 (CI, 1.15-2.40; p = .007) at 00:00-04:00 versus other timeslots. Episodes were less likely to be terminated by ATP in the 00:00-04:00 (success-to-failure ratio, 0.67; CI, 0.46-0.98; p = .039) and 08:00-12:00 (0.70; CI, 0.51-0.96; p = .02) timeslots, and most likely to be terminated by ATP between 12:00 and 16:00 (success-to-failure ratio 1.42; CI, 1.06-1.91; p = .02). CONCLUSION: VAs did not distribute uniformly over the 24 h, with a majority of episodes occurring from 08:00 to 16:00. Nocturnal episodes were more likely to be polymorphic. The efficacy of ATP depended on the time of delivery.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 96(3): E248-E256, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32012453

RESUMEN

BACKGROUND: A large trial established the favorable profile of a new polymer-free biolimus A9-eluting stent (PF-BES) with a 1-month dual antiplatelet therapy (DAPT) in high bleeding risk (HBR) patients. This is the first study comparing outcomes for a 1-month versus longer DAPT strategies following PF-BES-percutaneous coronary intervention (PCI). METHODS: All patients undergoing PF-BES-PCI (January 2016 to July 2018) were included in the multicenter CHANCE registry. Patients were stratified according to DAPT strategy at discharge (planned 1-month vs. planned >1-month). Primary outcomes were the 390-day estimates of a patient-oriented and of a device-oriented composite endpoints (POCE: death, myocardial infarction [MI] or target vessel revascularization; DOCE: cardiac death, target vessel-MI or ischemia-driven target lesion revascularization). Landmark analyses from 1-month post-PCI were carried. RESULTS: Following PF-BES-PCI, 328(40.3%) and 485(59.6%) patients were discharged with 1-month and longer DAPT (12 months [6-12]), respectively. Patients with a previous or index MI were less likely to be discharged on 1-month DAPT. Patients prescribed with 1-month DAPT were more likely to be at HBR than those with longer DAPT (90.2% vs. 69.9%, p = .001). No between-groups differences in the primary outcomes (planned 1-month vs. planned >1-month DAPT: POCE 11.9% vs. 13.2%, p = .747; DOCE: 4.8% vs. 8.1%, p = .500) were observed, also after adjusting for confoundings (POCE: adjusted-hazard ratio [adj-HR] 1.26, 95%CI 0.74-2.13; DOCE: adj-HR 1.00, 95%CI 0.49-1.99). Landmark analyses showed similar results. CONCLUSIONS: In a large all-comers registry of PF-BES PCI, no interaction of planned DAPT strategy (1-month vs. >1-month) with outcomes was found. This observation warrants investigation in adequately powered randomized studies (ClinicalTrials.gov NCT03622203).


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Terapia Antiplaquetaria Doble , Intervención Coronaria Percutánea/instrumentación , Inhibidores de Agregación Plaquetaria/administración & dosificación , Sirolimus/análogos & derivados , Anciano , Anciano de 80 o más Años , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Esquema de Medicación , Terapia Antiplaquetaria Doble/efectos adversos , Terapia Antiplaquetaria Doble/mortalidad , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Inhibidores de Agregación Plaquetaria/efectos adversos , Diseño de Prótesis , Sistema de Registros , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
4.
Europace ; 22(2): 225-231, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31665276

RESUMEN

AIMS: Clinical practice guidelines do not recommend discontinuation of long-term oral anticoagulation in patients with a high stroke risk after catheter ablation for atrial fibrillation (AF). Left atrial appendage closure (LAAC) with Watchman has emerged as an alternative to long-term anticoagulation for patients accepting of the procedural risks. We report on the long-term outcomes of combining catheter ablation procedures for AF and LAAC from multicentre registries. METHODS AND RESULTS: Data were pooled from two prospective, real-world Watchman LAAC registries running in parallel in Europe/Middle-East/Russia (EWOLUTION) and Asia/Australia (WASP) between 2013 and 2015. Of the 1140 patients, 142 subjects at 11 centres underwent a concomitant AF ablation and LAAC procedure. The mean CHA2DS2-VASc score was 3.4 ± 1.4 and HAS-BLED score 1.5 ± 0.9. Successful LAAC was achieved in 99.3% of patients. The 30-day device and/or procedure-related serious adverse event rate was 2.1%. After a mean follow-up time of 726 ± 91 days, 92% of patients remained off oral anticoagulation. The rates of the composite endpoint of ischaemic stroke/transient ischaemic attack/systemic thromboembolism were 1.09 per 100 patient-years (100-PY); and for non-procedural major bleeding were 1.09 per 100-PY. These represent relative reductions of 84% and 70% vs. expected rates per risk scores. CONCLUSION: The long-term outcomes from these international, multicentre registries show efficacy for all-cause stroke prevention and a significant reduction in late bleeding events in a population of high stroke risk post-ablation patients who have been withdrawn from oral anticoagulation.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Isquemia Encefálica , Ablación por Catéter , Accidente Cerebrovascular , Anticoagulantes , Asia/epidemiología , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Australia , Europa (Continente) , Humanos , Medio Oriente , Estudios Prospectivos , Sistema de Registros , Federación de Rusia , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
5.
Heart Lung Circ ; 29(7): 1078-1086, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31594723

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) is the most widely adopted strategy for paroxysmal atrial fibrillation (PAF) ablation. Limited evidence on acute results and late outcomes of cryoballoon (CB)-PVI in patients with structural heart disease (SHD) exist. The aim of this analysis was to compare acute procedural results and the 1-year recurrence rate of a single CB-PVI procedure in a PAF population with and without SHD. METHOD: From April 2012 to May 2017, a total of 2,031 patients with AF underwent CB-PVI and were followed prospectively in the framework of the One Shot TO Pulmonary vein isolation (1STOP) ClinicalService project, involving 36 Italian cardiology centres. We identified patients with SHD according to criteria proposed by current ESC guidelines: left ventricular (LV) systolic or diastolic dysfunction, long-standing hypertension with LV hypertrophy, and/or other structural heart disease. Data on procedural outcomes and long-term freedom from AF recurrence were evaluated. RESULTS: Our population consisted of 1,452 patients, of whom 282 (19.4%) were classified as having SHD. Compared to non-SHD patients, the SHD cohort was older (mean ± standard deviation, 62.9 ± 9.0 vs 58.2 ± 11.4 years; p < 0.001), was more frequently male (79.1% vs 69.8%; p < 0.002), had a higher thrombo-embolic risk (CHA2DS2VASc ≥2: 63.4% vs 40.2%; p < 0.001), had a higher body mass index (27.7 ± 3.9 vs 26.4 ± 3.9 kg/m2; p < 0.001), had a larger atrial diameter (43.8 ± 7.0 vs 40.2 ± 5.8 mm; p < 0.001), and had a lower LV ejection fraction (57.2 ± 7.7% vs 60.7 ± 6.0%; p < 0.001). At the time of ablation, 73% of patients were on class Ic or III anti-arrhythmic drugs. Procedure time (106.9 ± 41.5 vs 112.1 ± 46.8 min; p = 0.248), fluoroscopic time (28.7 ± 14.7 vs 28.6 ± 15.2 min; p = 0.819), and complication rate (3.9% vs 4.8%; p = 0.525) were not different between the SHD and non-SHD cohorts. However, the acute success rate (98.9% vs 97.7%; p = 0.016) was higher in patients with SHD. After a follow-up of 13.4 ± 12.8 months, freedom from symptomatic recurrence was 78.0% for SHD and 78.4% for non-SHD (p = 0.895). Recurrence rate was not related to either left atrial size or LVEF. In the SHD cohort, Class Ic or III anti-arrhythmic drugs treatment decreased from 70.7% of patients before ablation to 28.7% of patients after CB-PVI (p = 0.001). CONCLUSIONS: CB-PVI was extensively applied to treat patients with PAF. Unlike previous PVI experiences, the acute success and recurrence rate after a single procedure was not related to the presence of SHD or to the degree of cardiac remodelling. Further studies are required to define whether CB-PVI has a useful role in patients with a significantly reduced ejection fraction as those patients were under-represented in the current population.


Asunto(s)
Técnicas de Ablación/métodos , Fibrilación Atrial/cirugía , Criocirugía/métodos , Sistema de Conducción Cardíaco/fisiopatología , Taquicardia Paroxística/cirugía , Función Ventricular Izquierda/fisiología , Fibrilación Atrial/fisiopatología , Femenino , Estudios de Seguimiento , Sistema de Conducción Cardíaco/cirugía , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recurrencia , Taquicardia Paroxística/fisiopatología , Resultado del Tratamiento
6.
J Cardiovasc Electrophysiol ; 30(9): 1626-1635, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31165517

RESUMEN

INTRODUCTION: Clinical trials did not provide conclusive evidence concerning the benefit of prophylactic implantable cardioverter-defibrillators (ICDs) in patients with severe nonischemic cardiomyopathy (NICM). We aimed to compare incidence of appropriate sustained ventricular arrhythmia (SVA) and device therapy in ischemic cardiomyopathy (ICM) vs NICM ICD and/or cardiac resynchronization therapy (CRT-D) patients. METHODS AND RESULTS: We analyzed remote-monitoring data from devices of the Home Monitoring Expert Alliance network. SVA recordings were adjudicated by three independent electrophysiologists. Our cohort included 1,946 patients who received either an ICD (55%) or a CRT-D (45%) for primary prevention of sudden cardiac death. Median (interquartile range) age was 70 (62-77) years, 81% were male, and 52% were in the ICM group. Patients were remotely monitored for a maximum follow-up of 5 years. The 5-year product-limit estimate of SVA incidence in patients with an ICD was 47.3% (95% confidence interval [CI], 41.0%-53.9%) in the ICM group and 44.7% (36.9%-53.3%) in the NICM group. In patients with a CRT-D, SVA incidence was 45.7% (37.3%-55.0%) in ICM patients and 49.2% (40.4%-58.7%) in NICM patients. The adjusted hazard ratio for SVA in the ICM vs NICM group was 0.96 (95% CI: 0.70-1.30, P = .77) in ICD patients and 0.85 (95% CI: 0.61-1.18, P = .34) in CRT-D patients. SVAs triggered appropriate device therapies with similar incidence in all groups. CONCLUSION: In a large cohort of remotely monitored ICD and CRT-D recipients, SVA incidence did not significantly differ in ICM and NICM patients.


Asunto(s)
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Cardiomiopatías/fisiopatología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Prevención Primaria/instrumentación , Tecnología de Sensores Remotos , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Cardiomiopatías/diagnóstico , Cardiomiopatías/mortalidad , Causas de Muerte , Bases de Datos Factuales , Muerte Súbita Cardíaca/epidemiología , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Humanos , Incidencia , Italia/epidemiología , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidad , Isquemia Miocárdica/fisiopatología , Valor Predictivo de las Pruebas , Falla de Prótesis , Factores de Riesgo , Procesamiento de Señales Asistido por Computador , Factores de Tiempo , Resultado del Tratamiento
7.
Europace ; 21(3): 502-510, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30508076

RESUMEN

AIMS: Anatomical placement of the coronary sinus (CS) lead in basal or mid-ventricular positions of the posterior and lateral walls is associated with a better clinical outcome of cardiac resynchronization therapy (CRT). We hypothesized that optimization of CS lead placement targeted the right-to-left electrical delay (RLD) predicts an additional clinical benefit. METHODS AND RESULTS: The CS lead was placed according to current standards in 90 patients (Conventional group) and at the site of the longest RLD in 121 patients (RLD group). Non-responders were defined as those who died or underwent hospitalization for heart failure or did not improve in their Clinical Composite Score within 6 months. There were 67 (32%) non-responders. Compared with Conventional group, the final CS pacing site was more frequently in the basal segments in the RLD group (40% vs. 23%, P = 0.007); moreover, the RLD ratio (%RLD) of the total QRS width was longer (77 ± 13 vs. 73 ± 15, P = 0.05) and biventricular QRS shortened more from the baseline (-31 ± 21 ms vs. -21 ± 26 ms, P = 0.004). Nevertheless, the rate of non-responders was similar in the RLD and Conventional groups (35% vs. 28%, P = 0.30), as was %RLD (76 ± 16 vs. 75 ± 13, P = 0.66). QRS width during right ventricular (RV) pacing was an independent predictors of adverse outcome, with a 2% increase in the risk of failure for each 1 ms increase in QRS (P = 0.006). CONCLUSION: Optimization of CS lead placement targeted to latest electrical activation does not provide additional clinical benefit to anatomical placement in basal or mid-ventricular positions of the posterior and lateral walls. QRS width during RV pacing was a strong predictor of CRT failure. CLINICAL TRIAL REGISTRATION: http://www.clinicaltrials.gov. Unique identifier: NCT03204864.


Asunto(s)
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Seno Coronario/fisiopatología , Insuficiencia Cardíaca/terapia , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Progresión de la Enfermedad , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Italia , Masculino , Persona de Mediana Edad , Admisión del Paciente , Estudios Prospectivos , Recuperación de la Función , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
8.
N Engl J Med ; 383(1): 88-89, 2020 07 02.
Artículo en Inglés | MEDLINE | ID: mdl-32343497
9.
Europace ; 20(6): 949-955, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-29106523

RESUMEN

Aims: Long-term results from catheter ablation therapy for atrial fibrillation (AF) remain uncertain and clinical practice guidelines recommend continuation of long-term oral anticoagulation in patients with a high stroke risk. Left atrial appendage closure (LAAC) with Watchman has emerged as an alternative to long-term anticoagulation for patients accepting of the procedural risks. We report on the initial results of combining catheter ablation procedures for AF and LAAC in a multicentre registry. Methods and results: Data were pooled from two prospective, real-world Watchman LAAC registries running in parallel in Europe/Middle-East/Russia (EWOLUTION) and Asia/Australia (WASP) between 2013 and 2015. Of the 1140 patients, 139 subjects at 10 centres underwent a concomitant AF ablation and LAAC procedure. The mean CHA2DS2-VASc score was 3.4 ± 1.4 and HAS-BLED score 1.5 ± 0.9. Successful Watchman implantation was achieved in 100% of patients. The overall 30-day serious adverse event (SAE) rate was 8.7%, with the device and/or procedure-related SAE rate of 1.4%. One pericardial effusion required percutaneous drainage, but there were no strokes, device embolization, or deaths at 30 days. The 30-day bleeding SAE rate was 2.9% with 55% of patients prescribed NOAC and 38% taking warfarin post-procedure. Conclusion: The outcomes from these international, multicentre registries support the feasibility and safety of performing combined procedures of ablation and Watchman LAAC for patients with non-valvular AF and high stroke risk. Further data are needed on long-term outcomes for the hybrid technique on all-cause stroke and mortality.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Ablación por Catéter , Derrame Pericárdico , Complicaciones Posoperatorias/diagnóstico , Hemorragia Posoperatoria/diagnóstico , Implantación de Prótesis , Dispositivo Oclusor Septal , Anciano , Asia/epidemiología , Fibrilación Atrial/epidemiología , Australia/epidemiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Europa (Continente)/epidemiología , Estudios de Factibilidad , Femenino , Humanos , Masculino , Medio Oriente/epidemiología , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/etiología , Estudios Prospectivos , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/métodos , Sistema de Registros/estadística & datos numéricos , Federación de Rusia/epidemiología
10.
Europace ; 20(6): 1001-1009, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-29016759

RESUMEN

Aims: The Really ProMRI study evaluates magnetic resonance imaging (MRI) access for patients with cardiac implantable electronic devices (CIEDs) as well as the performance of magnetic resonance (MR)-conditional leads when undergoing MRI. Methods and results: Patients either with an MR-conditional pacemaker or implantable defibrillator (ICD) system or with at least a component (device or one or more leads) from an MR-conditional system, were asked to fill in a questionnaire when they were referred to a MR scan. The rate of prescription, denial, or execution of MR examinations was evaluated in a 1-year follow-up visit. In total, 555 patients [median age (interquartile range) 72.2 (62.2-78.6); 72% male] were enrolled, 49% (270) with a pacemaker, 51% (285) with an ICD system. Five-hundred and ten patients completed the follow-up period. A total of 37 MRI referrals were reported in 35 patients, with a consequent event rate of 7.0/100 patient-years (CI, 4.9-9.7). Fourteen were denied, while 23 [66%; (CI, 48-81%)] were performed. The number of patients with MR referrals was not statistically different between pacemaker and ICD groups (21 vs. 14; P = 0.178). The rate of scans performed was higher in the pacemaker subjects (19/23 vs. 4/14, P = 0.003), while it was similar between patients with or without a complete MR-conditional system (19/30 vs. 4/7, P = 0.606). Conclusion: In this study, we reported a 7.0/100 patient-year's event rate of MR prescriptions in CIED patients. Many examinations were denied, despite MR-conditional systems, especially in ICD patients. Regulatory and cultural changes are needed to allow wider access to MR imaging in CIED patients with MR-conditional systems.


Asunto(s)
Desfibriladores Implantables/estadística & datos numéricos , Imagen por Resonancia Magnética , Marcapaso Artificial/estadística & datos numéricos , Utilización de Procedimientos y Técnicas/estadística & datos numéricos , Anciano , Seguridad de Equipos/métodos , Seguridad de Equipos/normas , Femenino , Conocimientos, Actitudes y Práctica en Salud , Accesibilidad a los Servicios de Salud , Mal Uso de los Servicios de Salud/estadística & datos numéricos , Cardiopatías/terapia , Humanos , Italia , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Sistema de Registros/estadística & datos numéricos
11.
Pacing Clin Electrophysiol ; 40(1): 46-56, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27862043

RESUMEN

BACKGROUND: Catheter ablation (CA) is recommended for patients with drug refractory symptomatic atrial fibrillation (AF). "One Shot" catheters have been introduced to simplify CA and cryoballoon ablation (CBA) is spreading rapidly. Few real-world data are available on standard clinical practice, mainly from single-center experience. We aimed to evaluate clinical settings, demographics, and acute procedural outcomes in a large cohort of patients treated with CBA. METHODS: A total of 903 patients (73% male, mean age 59 ± 11) underwent pulmonary vein CBA. Correlations between the patient's inclusion time and clinical characteristics, procedure duration, acute success rate, and intraprocedural complications were evaluated. RESULTS: Seventy-seven percent of patients were affected by paroxysmal AF and 23% by persistent AF. Overall, acute success rate was 97.9% and periprocedural complications were observed in 35 (3.9%) patients, 13 (1.4%) of which were classified as major complications. With respect to the patient's inclusion time analysis, an increase in treatment of persistent AF was observed, a significant decrease in CBA times (procedure, ablation, and fluoroscopy: 136.0 ± 46.5 minutes, 28.8 ± 19.6 minutes, and 34.3 ± 15.4 minutes, respectively) was observed, with comparable acute success rate and intraprocedural complications over time. The rate of major complications was extremely low (1.4%); no death, atrioesophageal fistula, stroke, or other major periinterventional or late complications occurred. CONCLUSION: This series represents the largest experience of CBA in the treatment of AF that also describes the adoption curve of this relatively recent technology. CBA showed an excellent safety profile when performed in a large real-world clinical setting, with satisfactory acute success rate and, on average, short procedural times. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov (NCT01007474).


Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/estadística & datos numéricos , Crioterapia/estadística & datos numéricos , Complicaciones Posoperatorias/epidemiología , Venas Pulmonares/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Causalidad , Estudios de Cohortes , Comorbilidad , Estudios de Factibilidad , Femenino , Sistema de Conducción Cardíaco/cirugía , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/prevención & control , Prevalencia , Resultado del Tratamiento , Procedimientos Quirúrgicos Vasculares/estadística & datos numéricos , Adulto Joven
12.
Pacing Clin Electrophysiol ; 40(12): 1350-1357, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29023821

RESUMEN

AIMS: Left ventricular (LV) lead positioning at the site of delayed electrical activation is associated with better response to cardiac resynchronization therapy (CRT). We hypothesized that a long electrical conduction delay between right ventricular (RV) and coronary sinus (CS) leads during RV pacing (RLD index) is correlated with a better clinical outcome METHODS AND RESULTS: RLD is measured intraprocedurally, during RV pacing, as the time interval between the intracardiac electrograms of RV and CS leads. Initially, we did a prove-of-concept, feasibility, acute study in 97 patients who underwent CRT implantation. The CS lead position was assessed in the 40° right anterior oblique and 40° left anterior oblique views and assigned to one of 11 prespecified segments of a schematic eyeball depiction of the LV walls. Acute outcomes were QRS width during biventricular (BIV) pacing. The longest RLD were found in the basal and mid lateral segments; these accounted for 82% and 78%, respectively, of the total QRS width (%RLD). %RLD was inversely correlated with BIV-paced QRS (P  =  0.0001). A similar slope was present either in the 78 patients with preserved atrioventricular (AV) conduction and in the 19 without AV conduction (- 0.34 vs - 0.27, P  =  0.7). CONCLUSION: We showed that RLD can be used to guide lead placement at the time of CRT implantation and that it is correlated with BIV-QRS width, an indirect predictor of clinical outcome. Based on these findings we started the prospective, multicenter Optimal Pacing SITE 2 (OPSITE 2) trial with the objective to demonstrate a relationship between RLD and clinical outcomes assessed as death, hospitalization for heart failure, New York Heart Association class, and clinical composite score. The protocol is provided.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Seno Coronario , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Anciano , Terapia de Resincronización Cardíaca/normas , Protocolos Clínicos , Femenino , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Estudios Prospectivos , Factores de Tiempo
13.
Indian Pacing Electrophysiol J ; 16(2): 59-65, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27676162

RESUMEN

BACKGROUND: AtrioVentricular (AV) and InterVentricular (VV) delay optimization can improve ventricular function in Cardiac Resynchronization Therapy (CRT) and is usually performed by means of echocardiography. St Jude Medical has developed an automated algorhythm which calculates the optimal AV and VV delays (QuickOpt™) based on Intracardiac ElectroGrams, (IEGM), within 2 min. So far, the efficacy of the algorhythm has been tested acutely with standard lead position at right ventricular (RV) apex. Aim of this project is to evaluate the algorhythm performance in the mid- and long-term with RV lead located in mid-septum. METHODS: AV and VV delays optimization data were collected in 13 centers using both echocardiographic and QuickOpt™ guidance in CRTD implanted patients provided with this algorhythm. Measurements of the aortic Velocity Time Integral (aVTI) were performed with both methods in a random order at pre-discharge, 6-month and 12-month follow-up. RESULTS: Fifty-three patients were studied (46 males; age 68 ± 10y; EF 28 ± 7%). Maximum aVTI obtained by echocardiography at different AV delays, were compared with aVTI acquired at AV delays suggested by QuickOpt. The AV Pearson correlations were 0.96 at pre-discharge, 0.95 and 0,98 at 6- and 12- month follow-up respectively. After programming optimal AV, the same approach was used to compare echocardiographic aVTI with aVTI corresponding to the VV values provided by QuickOpt. The VV Pearson Correlation were 0,92 at pre-discharge, 0,88 and 0.90 at 6-month and 12- month follow-up respectively. CONCLUSIONS: IEGM-based optimization provides comparable results with echocardiographic method (maximum aVTI) used as reference with mid-septum RV lead location.

14.
Pacing Clin Electrophysiol ; 37(6): 697-702, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24665920

RESUMEN

BACKGROUND: Atrial fibrillation (AF) relapses, following transcatheter AF ablation, are frequently reported based on patients' symptoms, scheduled electrocardiograms (ECGs), or 24-hour Holter recordings. The aim of this study is to determine the incidence of asymptomatic and symptomatic AF recurrences, using continuous subcutaneous ECG monitoring, in the long-term follow-up of patients with paroxysmal or persistent AF undergoing transcatheter ablation. METHODS AND RESULTS: In total 113 consecutive patients symptomatic for paroxysmal or persistent AF were enrolled. All patients underwent pulmonary vein isolation plus left linear lesions. The insertable cardiac monitor (ICM), subcutaneously implanted during the ablation procedure, recorded the amount of AF per day (daily burden) and per last follow-up period (total AF burden). Based on symptoms and on scheduled 12-lead ECG performed during follow-up, 40 patients (35.4%) suffered AF recurrences. By means of ICM data, however, arrhythmia relapses were recorded within 75 patients (66.3%), of whom 35 (46.7%) were asymptomatic. Patients suffering symptomatic AF recurrences resulted, at univariate analysis, older (66.6 ± 8.4 years vs 61.6 ± 10.7 years) and suffering greater AF burden (88.8 ± 26.9% vs 8.0 ± 8.0%). CONCLUSIONS: AF ablation outcome based on patients' symptoms and/or scheduled ECGs underestimated relapses, as up to half of the patients, during a long-term follow-up, suffer asymptomatic recurrences.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/estadística & datos numéricos , Electrocardiografía Ambulatoria/estadística & datos numéricos , Fibrilación Atrial/epidemiología , Femenino , Humanos , Incidencia , Italia/epidemiología , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Recurrencia , Medición de Riesgo , Evaluación de Síntomas , Insuficiencia del Tratamiento , Resultado del Tratamiento
15.
Heart Rhythm ; 21(9): 1630-1639, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38493989

RESUMEN

BACKGROUND: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE. OBJECTIVE: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence. METHODS: Remote monitoring data from 2579 patients with no history of atrial fibrillation (23% pacemakers and 77% implantable cardioverter-defibrillators, of which 40% provided cardiac resynchronization therapy) were used to calculate the mean P-wave amplitude during 1 month after implantation. The association with AHRE incidence according to 4 strata of daily burden duration (≥15 minutes, ≥6 hours, ≥24 hours, ≥7 days) was investigated by adjusting the hazard ratio with the CHA2DS2-VASc score. RESULTS: The adjusted hazard ratio for 1-mV lower mean P-wave amplitude during the first month increased from 1.10 (95% confidence interval [CI], 1.05-1.15; P < .001) to 1.18 (CI, 1.09-1.28; P < .001) with AHRE duration strata from ≥15 minutes to ≥7 days independent of the CHA2DS2-VASc score. Of 871 patients with AHREs, those with 1-month P-wave amplitude <2.45 mV had an adjusted hazard ratio of 1.51 (CI, 1.19-1.91; P = .001) for progression of AHREs from ≥15 minutes to ≥7 days compared with those with 1-month P-wave amplitude ≥2.45 mV. Device-detected P-wave amplitudes decreased linearly during the 1 year before the first AHRE by 7.3% (CI, 5.1%-9.5%; P < .001 vs patients without AHRE). CONCLUSION: Device-detected P-wave amplitudes <2.45 mV were associated with an increased risk of AHRE onset and progression to persistent forms of AHRE independent of the patient's risk profile.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Humanos , Femenino , Masculino , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Anciano , Incidencia , Progresión de la Enfermedad , Medición de Riesgo/métodos , Atrios Cardíacos/fisiopatología , Marcapaso Artificial , Frecuencia Cardíaca/fisiología , Factores de Riesgo , Persona de Mediana Edad , Tecnología de Sensores Remotos/instrumentación , Estudios de Seguimiento
16.
J Cardiovasc Electrophysiol ; 24(1): 24-32, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23140485

RESUMEN

INTRODUCTION: Long-term outcome of AF ablation in patients with impaired LVEF is unknown. The aim of this study is to evaluate sinus rhythm (SR) maintenance, clinical status, and echocardiographic parameters over a long-term period following atrial fibrillation (AF) transcatheter ablation in patients with left ventricular ejection fraction (LVEF) <50%. METHODS AND RESULTS: A total of 196 patients (87.2% males, age 60.5 ± 10.2 years) with LVEF <50% underwent radiofrequency transcatheter ablation for paroxysmal (22.4%) or persistent (77.6%) AF. Patients were followed up for 46.2 (16.4-63.5) months regarding AF recurrences, functional class, and echocardiographic parameters. All patients underwent pulmonary vein isolation, while 167 (85.2%) required additional atrial lesions. Eleven (5.6%) patients suffered procedural complications. During follow-up, 58 (29.6%) patients required repeated ablations. At the follow-up end, 15 (7.7%) patients died, while 74 (37.8%) documented at least one episode of AF, atrial flutter, or atrial ectopic tachycardia. Eighty-three (47.2%) patients maintained antiarrhythmic drugs. During follow-up, NYHA class improved by at least one class more frequently among patients maintaining SR compared to those experiencing relapses (70.6% vs 47.9%, P = 0.003). LVEF showed a broader relative increase in patients maintaining SR (32.7% vs 21.4%; P = 0.047) and mitral regurgitation grading significantly decreased (P <0.001) only within these patients. At multivariable analysis SR maintenance emerged as an independent predictor (odds ratio 4.26, 95% CI 1.69-10.74, P = 0.002) of long-term clinical improvement (reduction in NYHA class ≥ 1 and relative increase in LVEF ≥ 10%). CONCLUSIONS: Although not substantially worse than in patients with preserved LVEF, AF ablation in patients with impaired LVEF is affected by high long-term recurrence rate. Among these patients SR maintenance is associated with greater clinical improvement.


Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/estadística & datos numéricos , Ablación por Catéter/estadística & datos numéricos , Disfunción Ventricular Izquierda/epidemiología , Disfunción Ventricular Izquierda/cirugía , Comorbilidad , Femenino , Humanos , Incidencia , Italia/epidemiología , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Resultado del Tratamiento
17.
Int J Cardiol ; 369: 48-53, 2022 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-35944772

RESUMEN

BACKGROUND: Myocardial injury (MINJ) is a well-recognized prognostic marker in different acute cardio-respiratory illnesses, nonetheless, its relevance in Influenza remains poorly defined. Our aim was to assess incidence, correlates, short and mid-term prognostic role of MINJ in Influenza. METHODS: Hospitalized patients (pts) with laboratory confirmed Influenza A or B underwent highly sensitive cardiac T Troponin (hs-cTnT) measurement at admission in four regional Swiss hospitals during the 2018-2019 epidemic. MINJ was defined as hs-cTnT >14 ng/L. Clinical, laboratory and outcome data were prospectively collected. The primary endpoint was mortality at 28 days while the composite of mortality, admission to intensive care unit (ICU) or need for mechanical ventilation at 28-days and mortality at 30-months were set as secondary endpoints. RESULTS: The presence of MINJ was assessed within 48 h from admission in 145 consecutive hospitalized pts, being evident in 94 (65.5%) pts and associated with older age, higher C-reactive protein levels, renal impairment or chronic obstructive pulmonary disease. At a 28-days follow-up, 7 deaths (4.8%) occurred, all in patients with MINJ at admission (log-rank p = 0.048). MINJ was strongly associated with occurrence of death, ICU admission or mechanical ventilation (OR 5.74, 95% CI 1.28-53.29; p = 0.015). After a median follow-up of 32.7 months (IQR 32.2-33.4), 15 (10.3%) deaths occurred, all among pts with MINJ at index hospitalization leading to a higher mortality at follow-up among patients with MINJ (log-rank p = 0.003). CONCLUSIONS: MINJ is common in patients hospitalized for Influenza and is able to stratify the risk of short-term adverse events and mid-term mortality.


Asunto(s)
Gripe Humana , Biomarcadores , Proteína C-Reactiva , Humanos , Gripe Humana/diagnóstico , Pronóstico , Estudios Prospectivos , Troponina T
18.
J Interv Card Electrophysiol ; 64(3): 607-619, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34709504

RESUMEN

PURPOSE: The purpose of this study was to assess the available mortality risk stratification models for implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRT-D) patients. METHODS: We conducted a review of mortality risk stratification models and tested their ability to improve prediction of 1-year survival after implant in a database of patients who received a remotely controlled ICD/CRT-D device during routine care and included in the independent Home Monitoring Expert Alliance registry. RESULTS: We identified ten predicting models published in peer-reviewed journals between 2000 and 2021 (Parkash, PACE, MADIT, aCCI, CHA2DS2-VASc quartiles, CIDS, FADES, Sjoblom, AAACC, and MADIT-ICD non-arrhythmic mortality score) that could be tested in our database as based on common demographic, clinical, echocardiographic, electrocardiographic, and laboratory variables. Our cohort included 1,911 patients with left ventricular dysfunction (median age 71, 18.3% female) from sites not using any risk stratification score for systematic patient screening. Patients received an ICD (53.8%) or CRT-D (46.2%) between 2011 and 2017, after standard physician evaluation. There were 56 deaths within 1-year post-implant, with an all-cause mortality rate of 2.9% (95% confidence interval [CI], 2.3-3.8%). Four predicting models (Parkash, MADIT, AAACC, and MADIT-ICD non-arrhythmic mortality score) were significantly associated with increased risk of 1-year mortality with hazard ratios ranging from 3.75 (CI, 1.31-10.7) to 6.53 (CI 1.52-28.0, p ≤ 0.014 for all four). Positive predictive values of 1-year mortality were below 25% for all models. CONCLUSION: In our analysis, the models we tested conferred modest incremental predicting power to ordinary screening methods.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Terapia de Resincronización Cardíaca/métodos , Dispositivos de Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables/efectos adversos , Femenino , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
19.
JACC Clin Electrophysiol ; 8(12): 1553-1562, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36543505

RESUMEN

BACKGROUND: Causes of sex differences in incidence of sustained ventricular arrhythmias (SVAs) are poorly understood. OBJECTIVES: This study aims to investigate sex-specific risk of SVAs and device therapies by balancing sex groups in relation to several baseline characteristics with the propensity score (PS). METHODS: We used a large remote monitoring dataset from implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds). Study endpoints were time to the first appropriate SVA, time to the first device therapy for SVA, and time to the first ICD shock. Results were compared between females and a PS-matched male subgroup. RESULTS: In a cohort of 2,532 patients with an ICD or CRT-D (median age, 70 years), 488 patients (19.3%) were women. After selecting 488 men PS-matched for 19 variables relative to baseline demographics, implant indications, principal comorbidities, and concomitant therapy, yet the SVA rate at the 2.1-year median follow-up was significantly lower in women than in man (adjusted HR: 0.65; 95% CI: 0.51-0.81; P < 0.001). Women also showed a reduced risk of any device therapy (HR: 0.59; 95% CI: 0.45-0.76; P < 0.001) and shocks (HR: 0.66; 95% CI: 0.47-0.94; P = 0.021). Differences in sex-specific SVA risk profile were not confirmed in CRT-D patients (HR: 0.78; 95% CI: 0.55-1.09; P = 0.14) nor in those with an ejection fraction <30% (HR: 0.80; 95% CI: 0.52-1.23; P = 0.31). CONCLUSIONS: After matching demographics, indications, principal comorbidities, and concomitant therapy, women still exhibited a lower SVA risk profile than men, except in the subgroups of CRT-D or/and ejection fraction <30%.


Asunto(s)
Desfibriladores Implantables , Humanos , Masculino , Femenino , Anciano , Desfibriladores Implantables/efectos adversos , Puntaje de Propensión , Resultado del Tratamiento , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Cardioversión Eléctrica
20.
Pacing Clin Electrophysiol ; 34(3): 339-47, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21070258

RESUMEN

INTRODUCTION: In the right ventricle, selective site pacing (SSP) has been shown to avoid detrimental hemodynamic effects induced by right ventricular apical pacing and, in the right atrium, to prevent the onset of atrial fibrillation and to slow down disease progression. The purpose of our multicenter observational study was to describe the use of a transvenous 4-French catheter-delivered lead for SSP in the clinical practice of a large number of centers. METHODS: We enrolled 574 patients in whom an implantable device was indicated. In all patients, SSP was achieved by using the Select Secure System™ (Medtronic Inc., Minneapolis, MN, USA). RESULTS: In 570 patients, the lead was successfully implanted. In 125 patients, atrial SSP was performed: in 75 (60%) the lead was placed in the interatrial septum, in 31 (25%) in the coronary sinus ostium, and in 19 (15%) in the Bachman bundle. Ventricular SSP was undertaken in 138 patients: in 105 (76%) the high septal right ventricular outflow tract (RVOT) position was paced, in seven (5%) the high free-wall RVOT, in 25 (18%) the low septal RVOT, and in one (1%) the low free-wall RVOT. In the remaining 307 patients, the His zone was paced: in 87 (28%) patients, direct His-bundle pacing and in 220 (72%) patients para-hisian pacing was achieved. Adequate pacing parameters and a lead-related complication rate of 2.6% were recorded during a follow-up of 20 ± 10 months. CONCLUSIONS: Our results demonstrated that many sites, in the right atrium, in the right ventricle, and in His-bundle region, can be paced using the Select Secure System™.


Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/prevención & control , Marcapaso Artificial/estadística & datos numéricos , Anciano , Falla de Equipo , Europa (Continente)/epidemiología , Femenino , Humanos , Masculino , Prevalencia , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA