1.
Eur Radiol ; 2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-38197916

RESUMEN

OBJECTIVES: Epicardial adipose tissue (EAT) remodeling is associated with atrial fibrillation (AF). Left atrial (LA) EAT dispersion on cardiac CT is a non-invasive imaging biomarker reflecting EAT heterogeneity. We aimed to investigate the association of LA EAT dispersion with AF recurrence after pulmonary vein isolation (PVI). METHODS: In a prospective registry of consecutive patients undergoing first PVI, mean EAT attenuation values were measured on contrast-enhanced cardiac CT scans in Hounsfield units (HU) within low (- 195 to - 45 HU) and high (- 44 to - 15 HU) threshold EAT compartments around the left atrium (LA). EAT dispersion was defined as the difference between the mean HU values within the two EAT compartments. Continuous variables were compared between groups using the Mann-Whitney U test and cox proportional hazard models were used to calculate hazard ratios of predictors of 1-year AF recurrence. RESULTS: A total of 208 patients were included, 135 with paroxysmal AF and 73 with persistent AF. LA EAT dispersion was significantly larger in patients with persistent compared to paroxysmal AF (52.6 HU vs. 49.9 HU; p = 0.001). After 1 year of follow-up, LA EAT dispersion above the mean (> 50.8 HU) was associated with a higher risk of AF recurrence (HR 2.3, 95% CI 1.5-3.6; p < 0.001). It retained its predictive value when corrected for age, sex, body mass index, LA volume, and AF type (HR 2.8, 95% CI 1.6-4.6; p < 0.001). CONCLUSION: A larger LA EAT dispersion on contrast-enhanced cardiac CT scans, reflecting EAT heterogeneity, is independently associated with AF recurrence after PVI. CLINICAL RELEVANCE STATEMENT: Based on LA EAT dispersion assessment, a more accurate risk stratification and patient selection may be possible based on a pre-procedural cardiac CT when planning PVI. KEY POINTS: • Epicardial adipose tissue (EAT) remodeling is associated with atrial fibrillation (AF). • A larger left atrial EAT dispersion in a pre-procedural cardiac CT was associated with a higher 1-year AF recurrence risk after pulmonary vein isolation. • A pre-procedural cardiac CT with left atrial EAT dispersion assessment may provide a more accurate risk stratification and patient selection for PVI.

2.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38597211

RESUMEN

AIMS: Pulmonary vein isolation (PVI) is increasingly performed in patients with atrial fibrillation (AF). Both AF phenotype and left atrial (LA) volume have been shown to influence ablation outcome. The inter-relationship of the two is incompletely understood. We aimed to investigate the impact of AF phenotype vs. LA volume on outcome after PVI. METHODS AND RESULTS: In a retrospective analysis of a prospective registry of patients undergoing a first PVI, the association of AF phenotype and LA volume index (LAVI) was assessed as well as their impact on AF recurrence during follow-up. Overall, 476 patients were enrolled (median age 63 years, 29% females, 65.8% paroxysmal AF). Obesity, hypertension, chronic kidney disease, and heart failure were all significantly more frequent in persistent AF. After 1 year, single-procedure, freedom from arrhythmia recurrence was 61.5%. Patients with paroxysmal AF had better outcomes compared with patients with persistent AF (65.6 vs. 52.7%, P = 0.003), as had patients with no/mild vs. moderate/severe LA dilation (LAVI <42 mL/m2 67.1% vs. LAVI ≥42 mL/m2 53%, P < 0.001). The combination of both parameters refined prediction of 1-year recurrence (P < 0.001). After adjustment for additional clinical risk factors in multivariable Cox proportional hazard analysis, both AF phenotype and LAVI ≥42 mL/m2 contributed significantly towards the prediction of 1-year recurrence. CONCLUSION: Atrial fibrillation phenotype and LA volume are independent predictors of outcome after PVI. Persistent AF with no/mild LA dilation has a similar risk of recurrence as paroxysmal AF with a moderate/severe LA dilation and should be given similar priority for ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Femenino , Humanos , Persona de Mediana Edad , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Venas Pulmonares/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Fenotipo , Recurrencia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
3.
Pacing Clin Electrophysiol ; 47(6): 853-861, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38655610

RESUMEN

AIMS: Pacemaker (PM) patients may require a subsequent upgrade to an implantable cardioverter defibrillator (ICD). Limited data exists on this patient population. We sought to characterize this population, to assess predictors for ICD upgrade, and to report the outcome. METHODS: From our prospective PM and ICD implantation registry, all patients who underwent PM and/or ICD implantations at our center were analyzed. Patient characteristics and outcomes of PM patients with subsequent ICD upgrade were compared to age- and sex-matched patients with de novo ICD implantation, and to PM patients without subsequent upgrade. RESULTS: Of 1'301 ICD implantations, 60 (5%) were upgraded from PMs. Median time from PM implantation to ICD upgrade was 2.6 years (IQR 1.3-5.4). Of 2'195 PM patients, 28 patients underwent subsequent ICD upgrades, corresponding to an estimated annual incidence of an ICD upgrade of at least 0.33%. Lower LVEF (p = .05) and male sex (p = .038) were independent predictors for ICD upgrade. Survival without death, transplant and LVAD implantation were worse both for upgraded ICD patients compared to matched patients with de novo ICD implantation (p = .05), as well as for PM patients with subsequent upgrade compared to matched PM patients not requiring an upgrade (p = .036). CONCLUSIONS: One of 20 ICD implantations are upgrade of patients with a PM. At least one of 30 PM patients will require an ICD upgrade in the following 10 years. Predictors for ICD upgrade are male sex and lower LVEF at PM implantation. Upgraded patients have worse outcomes.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Masculino , Femenino , Anciano , Resultado del Tratamiento , Estudios Prospectivos , Sistema de Registros , Persona de Mediana Edad , Factores de Riesgo , Tasa de Supervivencia
4.
J Cardiovasc Electrophysiol ; 34(5): 1183-1191, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37003265

RESUMEN

INTRODUCTION: Anomalous cardiac veins are not rare and pulmonary vein (PV) isolation for atrial fibrillation (AF) treatment should include these veins. Pulsed-field ablation (PFA) is a novel technology for AF ablation with excellent efficacy and safety profile. In this case series, we describe our first experience of isolation of anomalous cardiac veins using PFA in patients with AF. METHODS: We report a series of patients with congenital anomalies of the cardiac veins and AF, treated with PFA. All patients underwent cardiac computed tomography for procedural planning. RESULTS: We included five patients (four males). Anomalous cardiac veins included a connection of a left common ostium to the coronary sinus, a partial and complete drainage of the right superior PV into the superior vena cava (SVC) with and without additional atrial septal defect, a persistent left SVC and an anomalous posterior PV. All anomalous PVs were isolated using PFA. No phrenic nerve palsy or other complications occurred. PFA of an abnormal right superior PV draining into the distal SVC was possible without affecting the sinus node. After a median of 4 months, four patients were free of recurrence. One patient had recurrent AF and perimitral reentry tachycardia, probably facilitated by PFA in the mitral isthmus region during isolation of an anomalous connection of the left common ostium to the coronary sinus. CONCLUSIONS: Using systematic preprocedural imaging and three-dimensional-electroanatomic mapping, the currently available PFA system seems well suited, efficient, and versatile for the treatment of AF in patients with anomalous cardiac veins.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Vena Cava Superior Izquierda Persistente , Venas Pulmonares , Masculino , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/diagnóstico por imagen , Vena Cava Superior/diagnóstico por imagen , Vena Cava Superior/cirugía , Corazón , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Resultado del Tratamiento
5.
Pacing Clin Electrophysiol ; 46(10): 1186-1196, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37616339

RESUMEN

BACKGROUND: Prediction of the chamber of origin in patients with outflow tract ventricular arrhythmias (OTVA) remains challenging. A clinical risk score based on age, sex and presence of hypertension was associated with a left ventricular outflow tract (LVOT) origin. We aimed to validate this clinical score to predict an LVOT origin in patients with OTVA. METHODS: In a two-center observational cohort study, unselected patients undergoing catheter ablation (CA) for OTVA were enrolled. All procedures were performed using an electroanatomical mapping system. Successful ablation was defined as a ≥80% reduction of the initial overall PVC burden after 3 months of follow-up. Patients with unsuccessful ablation were excluded from this analysis. RESULTS: We included 187 consecutive patients with successful CA of idiopathic OTVA. Mean age was 52 ± 15 years, 102 patients (55%) were female, and 74 (40%) suffered from hypertension. A LVOT origin was found in 64 patients (34%). A score incorporating age, sex and presence of hypertension reached 73% sensitivity and 67% specificity for a low (0-1) and high (2-3) score, to predict an LVOT origin. The combination of one ECG algorithm (V2 S/V3 R-index) with the clinical score resulted in a sensitivity and specificity of 81% and 70% for PVCs with R/S transition at V3 . CONCLUSION: The published clinical score yielded a lower sensitivity and specificity in our cohort. However, for PVCs with R/S transition at V3, the combination with an existing ECG algorithm can improve the predictability of LVOT origin.

6.
Pacing Clin Electrophysiol ; 46(5): 365-375, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36912446

RESUMEN

BACKGROUND: The implantation procedure of left ventricular (LV) leads and the management of cardiac resynchronization therapy (CRT) patients can be challenging. The IS-4 standard for CRT offers additional pacing vectors compared to bipolar leads (IS-1). IS-4 leads improve procedural outcome and may also result in lower adverse events during follow-up (FU) and improve clinical outcome in CRT patients. Further long-term FU data comparing the two lead designs are necessary. METHODS: In this retrospective, single-center study we included adult patients implanted with a CRT-Defibrillator (CRT-D) or CRT-Pacemaker (CRT-P) with a quadripolar (IS-4 group) or bipolar (IS-1 group) LV lead and with available ≥3 years clinical FU. The combined primary endpoint was a combination of predefined, lead-related adverse events. Secondary endpoints were all single components of the primary endpoint. RESULTS: Overall, 133 patients (IS-4 n = 66; IS-1 n = 67) with a mean FU of 4.03 ± 1.93 years were included. Lead-related adverse events were less frequent in patients with an IS-4 lead than with an IS-1 lead (n = 8, 12.1% vs. n = 23, 34.3%; p = .002). The secondary outcomes showed a lower rate of LV lead deactivation/explantation and LV lead dislodgement/dysfunction (4.5% vs. 22.4%; p = .003; 4.5% vs. 17.9%; p = .015, respectively) in the IS-4 patient group. Less patients suffered from unresolved phrenic nerve stimulation with an IS-4 lead (3.0% vs. 13.4%; p = .029). LV lead-related re-interventions were fewer in case of an IS-4 lead (6.1% vs. 17.9%; p = .036). CONCLUSION: In this retrospective analysis, the IS-4 LV lead is associated with lower lead-related complication rates than the IS-1 lead at long-term FU.


Asunto(s)
Trastorno Bipolar , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Disfunción Ventricular Izquierda , Adulto , Humanos , Terapia de Resincronización Cardíaca/métodos , Dispositivos de Terapia de Resincronización Cardíaca , Estudios Retrospectivos , Trastorno Bipolar/terapia , Resultado del Tratamiento , Disfunción Ventricular Izquierda/terapia , Sistema de Registros , Electrodos Implantados
7.
Circulation ; 143(7): 739-752, 2021 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-33587657

RESUMEN

Sex-related differences in prevalence, clinical presentation, and outcome of cardiac channelopathies are increasingly recognized, despite their autosomal transmission and hence equal genetic predisposition among sexes. In congenital long-QT syndrome, adult women carry a greater risk for Torsades de pointes and sudden cardiac death than do men. In contrast, Brugada syndrome is observed predominantly in adult men, with a considerably higher risk of arrhythmic sudden cardiac death in adult men than in women. In both conditions, the risk for arrhythmias varies with age. Sex-associated differences appear less evident in other cardiac channelopathies, likely a reflection of their rare(r) occurrence and our limited knowledge. In several cardiac channelopathies, sex-specific predictors of outcome have been identified. Together with genetic and environmental factors, sex hormones contribute to the sex-related disparities in cardiac channelopathies through modulation of the expression and function of cardiac ion channels. Despite these insights, essential knowledge gaps exist in the mechanistic understanding of these differences, warranting further investigation. Precise application of the available knowledge may improve the individualized care of patients with cardiac channelopathies. Promoting the reporting of sex-related phenotype and outcome parameters in clinical and experimental studies and advancing research on cardiac channelopathy animal models should translate into improved patient outcomes. This review provides a critical digest of the current evidence for sex-related differences in cardiac channelopathies and emphasizes their clinical implications and remaining gaps requiring further research.


Asunto(s)
Enfermedades Cardiovasculares/genética , Canalopatías/genética , Femenino , Humanos , Masculino , Factores Sexuales
8.
Radiology ; 305(1): 56-65, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35670718

RESUMEN

Background The association of epicardial adipose tissue (EAT) and its metabolic activity with atrial fibrillation (AF) is an area of active investigation. Left atrial (LA) enhancing EAT (e-EAT) at cardiac CT may be a noninvasive surrogate marker for the metabolic activity of EAT. Purpose To determine the relationship between LA e-EAT and recurrence after AF ablation. Materials and Methods In a secondary analysis of a prospective registry of consecutive patients (from July 2018 to December 2019) undergoing first AF ablation, total and LA EAT were segmented on preprocedural noncontrast- and contrast-enhanced cardiac CT scans. LA e-EAT volume fraction was defined as the LA EAT volume difference between the noncontrast- and contrast-enhanced scan divided by the total LA EAT volume on the noncontrast-enhanced scan (threshold values, -15 HU to -195 HU). Continuous variables were compared between groups by using the Mann-Whitney U test. Cox proportional hazard models were used to calculate hazard ratios of predictors of 1-year AF recurrence. Results A total of 212 patients (mean age, 64 years; 159 men) who underwent a first AF ablation were included (paroxysmal AF, 64%; persistent AF, 36%). The LA EAT volume was higher in patients with persistent versus paroxysmal AF (50 cm3 [IQR, 37-72] vs 37 [IQR, 27-49]; P < .001), but no difference was found for LA e-EAT (P = .09). After 1 year of follow-up, AF recurrence rate was 77 of 212 (36%). LA e-EAT above the mean (>33%) was associated with a higher risk of AF recurrence (hazard ratio [HR], 2.1; 95% CI: 1.3, 3.3; P < .01). In a multivariable Cox regression analysis, LA e-EAT retained its predictive value when corrected for sex, age, AF phenotype, LA volume index, and LA EAT volume (HR, 1.9; 95% CI: 1.1, 3.1; P = .02). Conclusion Left atrial enhancing epicardial adipose tissue was independently associated with recurrence after atrial fibrillation ablation. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Stojanovska in this issue.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Tejido Adiposo/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Atrios Cardíacos , Humanos , Recurrencia , Tomografía Computarizada por Rayos X/métodos
9.
J Cardiovasc Electrophysiol ; 33(7): 1617-1627, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35614867

RESUMEN

INTRODUCTION: Conventional transvenous pacemaker leads may interfere with the tricuspid valve leaflets, tendinous chords, and papillary muscles, resulting in significant tricuspid valve regurgitation (TR). Leadless pacemakers (LLPMs) theoretically cause less mechanical interference with the tricuspid valve apparatus. However, data on TR after LLPM implantation are sparse and conflicting. Our goal was to investigate the prevalence of significant TR before and after LLPM implantation. METHODS: Patients who received a leadless LLPM (Micra™ TPS, Medtronic) between May 2016 and May 2021 at our center were included in this observational study if they had at least a pre- and postinterventional echocardiogram (TTE). The evolution of TR severity was assessed. Following a systematic literature review on TR evolution after implantation of a LLPM, data were pooled in a random-effects meta-analysis. RESULTS: We included 69 patients (median age 78 years [interquartile range (IQR) 72-84 years], 26% women). Follow-up duration between baseline and follow-up TTE was 11.4 months (IQR 3.5-20.1 months). At follow-up, overall TR severity was not different compared to baseline (p = .49). Six patients (9%) had new significant TR during follow-up after LLPM implantation, whereas TR severity improved in seven patients (10%). In the systematic review, we identified seven additional articles that investigated the prevalence of significant TR after LLPM implantation. The meta-analysis based on 297 patients failed to show a difference in significant TR before and after LLPM implantation (risk ratio 1.22, 95% confidence interval 0.97-1.53, p = .11). CONCLUSION: To date, there is no substantial evidence for a significant change in TR after implantation of a LLPM.


Asunto(s)
Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Anciano , Anciano de 80 o más Años , Ecocardiografía , Femenino , Humanos , Masculino , Estudios Observacionales como Asunto , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/epidemiología
10.
Europace ; 24(8): 1248-1255, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35699395

RESUMEN

AIMS: To validate the performance of a multipolar pulsed-field ablation (PFA) catheter compared to a standard pentaspline 3D-mapping catheter for endpoint assessment of pulmonary vein isolation (PVI). PFA for PVI using single-shot devices combines the benefits of high procedural efficacy and safety. A newly available multipolar PFA catheter allows real-time recording of pulmonary vein (PV) signals during PVI. METHODS AND RESULTS: Patients undergoing first PVI using PFA with the standard ablation protocol (eight applications per PV) were studied. Entrance and exit block (10 V/2 ms) were assessed using the PFA catheter. Subsequently, a high-density 3D electroanatomical bipolar voltage map (3D-EAM) was constructed using a standard pentaspline 3D-mapping catheter. Additional PFA applications were delivered only after confirmation of residual PV connection by 3D-EAM. In 56 patients, 213 PVs were targeted for ablation. Acute PVI was achieved in 100% of PVs: in 199/213 (93%) PVs with the standard ablation protocol alone and in the remaining 14 PVs after additional PFA applications. The accuracy of PV assessment with the PFA catheter after the standard ablation protocol was 91% (194/213 veins). In 5/213 (2.3%) PVs, the PFA catheter incorrectly indicated PV-isolation. In 14/213 (6.6%), the PFA catheter incorrectly indicated residual PV-conduction due to high-output pace-capture. Lowering the output to 5 V/1 ms reduced this observation to 0.9% (2/213) and increased the overall accuracy to 97% (206/213). CONCLUSION: A novel multipolar PFA catheter allows reliable endpoint assessment for PVI. Due to its design, far-field sensing and high-output pace-capture can occur. Lowering the pacing output increases the accuracy from 91 to 97%.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Catéteres , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento
11.
Europace ; 24(12): 1926-1932, 2022 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-35727739

RESUMEN

AIMS: The aim of the study was to compare the 1-year efficacy and safety of a novel cryoballoon (NCB) ablation system (POLARx; Boston Scientific) for pulmonary vein isolation (PVI) compared with the standard cryoballoon (SCB) system (Arctic Front, Medtronic). METHODS AND RESULTS: Consecutive patients with atrial fibrillation (AF) undergoing PVI using the NCB and the SCB at two centres were included. We report 1-year efficacy after 12 months, short-term safety and hospitalizations within the blanking period, and predictors for AF recurrence. In case of repeat procedures, pulmonary vein (PV) reconnection patterns were characterized. Eighty patients (age 66 ± 10 years, ejection fraction 57 ± 10%, left atrial volume index 39 ± 13 mL/m2, paroxysmal AF in 64%) were studied. After a single procedure and a follow-up of 12 months, 68% in the NCB group and 70% in the SCB group showed no recurrence of AF/atrial tachycardias (P = 0.422). One patient in the NCB group suffered a periprocedural stroke with full recovery. There were no differences regarding hospitalizations during follow-up between the groups. PV reconnection observed during 12 repeat procedures (4 NCB, 8 SCB) pattern was comparable between the groups with more reconnections in the right-sided compared with the left-sided PVs. CONCLUSION: In this multicentre study comparing two currently available cryoballoon ablation systems for PVI, no differences were observed in the efficacy and safety during a follow-up of 12 months.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Persona de Mediana Edad , Anciano , Criocirugía/efectos adversos , Criocirugía/métodos , Resultado del Tratamiento , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
12.
J Cardiovasc Electrophysiol ; 32(6): 1610-1619, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33928711

RESUMEN

INTRODUCTION: Chemical ablation by retrograde infusion of ethanol into the vein of Marshall (VOM-EI) can facilitate the achievement of mitral isthmus block. This study sought to describe the efficacy and safety of this technique. METHODS AND RESULTS: Twenty-two consecutive patients (14 males, median age 71 years) with attempted VOM-EI for mitral isthmus ablation were included in the study. VOM-EI was successfully performed with a median of 4 ml of 96% ethanol in 19 patients (86%) and the mitral isthmus was successfully blocked in all (100%). Touch up endocardial and/or epicardial ablation after VOM-EI was necessary for 12 patients (63%). Perimitral flutter was present in 12 patients (63%) during VOM-EI and terminated or slowed by VOM-EI in 4 and 3 patients, respectively. The low-voltage area of the mitral isthmus region increased from 3.1 cm2 (interquartile range [IQR] 0-7.9) before to 13.2 cm2 (IQR: 8.2-15.0) after VOM-EI and correlated significantly with the volume of ethanol injected (p = .03). Median high-sensitive cardiac troponin-T increased significantly from 330 ng/L (IQR: 221-516) the evening of the procedure to 598 ng/L (IQR: 382-769; p = .02) the following morning. A small pericardial effusion occurred in three patients (16%), mild pericarditis in one (5%), and uneventful VOM dissection in two (11%). After a median follow-up of 3.5 months (IQR: 3.0-11.0), 10 of 18 patients (56%) with VOM-EI and available follow-up had arrhythmia recurrence. Repeat ablation was performed in five patients (50%) and peri-mitral flutter diagnosed in three (60%). CONCLUSION: VOM-EI is feasible, safe, and effective to achieve acute mitral isthmus block.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Etanol/efectos adversos , Humanos , Masculino , Recurrencia , Venas
13.
Pacing Clin Electrophysiol ; 44(4): 703-710, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33675240

RESUMEN

BACKGROUND: Radiofrequency catheter ablation of idiopathic premature ventricular complexes (PVCs) is an effective method for eliminating symptoms and preventing/reversing arrhythmia-induced cardiomyopathy. One reason for procedural failure is low PVC frequency during the procedure. We aimed to investigate the relation between pre-procedural PVC burden and outcome of idiopathic PVC catheter ablation. METHODS: Patients who underwent idiopathic PVC ablation between 2013 and 2019 at two tertiary referral centers were retrospectively included. All procedures were performed using irrigated-tip ablation catheters and a 3D electro-anatomical mapping system. Sustained ablation success was defined as a ≥80% reduction of pre-procedural PVC burden determined by 24h-Holter at follow-up. RESULTS: Overall, 254 patients (median age 54 years [IQR 42-64]; 47% male) were enrolled. The median pre-ablation PVC-burden was 22% (IQR 11-31%), which was reduced to a post-ablation PVC burden of 0.3% (IQR 0-4%) after a median of 90 days. Sustained ablation success was achieved in 182 patients (72%). Pre-procedural PVC burden did not differ between patients with sustained ablation success and recurrence during follow-up (median 21% vs. 22%, p = .76). When assessed in pre-ablation PVC-burden groups of ≤5%, 6-15%, 16-30%, and ≥31%, sustained ablation success was achieved in 67%, 75%, 71%, and 72%, respectively, with no significant difference (p = .89). Sustained ablation outcome for PVC-burden ≤5% versus >5% showed no difference either (67% vs. 72%, p = .52). CONCLUSIONS: Pre-procedural Holter-determined PVC burden does not predict the outcome of idiopathic PVC ablation. Thus, catheter ablation may be a reasonable first choice also for patients with symptomatic yet rare PVCs.


Asunto(s)
Ablación por Catéter , Complejos Prematuros Ventriculares/fisiopatología , Complejos Prematuros Ventriculares/cirugía , Adulto , Anciano , Electrocardiografía Ambulatoria , Mapeo Epicárdico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Suiza
14.
Europace ; 22(6): 939-946, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-32361742

RESUMEN

AIMS: Leadless cardiac pacemaker (PM) implantation differs from conventional PM implantation. While the procedure has been considered safe, recent real-world data raised concerns about the learning curve of new operators and their implantation quality. The goal of this study was to investigate the influence of the first operator's experience on leadless PM implantation quality and procedural efficiency. METHODS AND RESULTS: We performed a bicentric analysis of all Micra TPS™ implantations in two large tertiary referral hospitals. We assessed both leadless PM implantation quality based on the absence of complications (requiring intervention or prolonged hospitalization), good electrical performance (pacing threshold ≤ 1.5 V/0.24 ms, R-wave amplitude > 5 mV), and acceptable fluoroscopy duration (<10 min) as well as procedural efficiency in relation to the operator's experience. Univariate and multivariate logistic regression analyses were performed to identify predictors for implantation quality and procedural efficiency. Leadless PM implantation was successful in 106/111 cases (95.5%). Three patients (2.7%) experienced acute complications (one cardiac tamponade, one femoral bleeding, one posture-related PM exit block). Multivariate analysis showed that implantation quality of more experienced first operators was higher [odds ratio 1.09 (95% confidence interval 1.00-1.19), P = 0.05]. Procedural efficiency increased with operator experience as evidenced by an inverse correlation of procedure time, time to the first deployment, fluoroscopy time, and the number of procedures performed (all P < 0.05). CONCLUSION: The operator's learning curve is a critical factor for leadless PM implantation quality and procedural efficiency.


Asunto(s)
Marcapaso Artificial , Cateterismo Cardíaco , Estimulación Cardíaca Artificial , Humanos , Oportunidad Relativa , Resultado del Tratamiento
15.
Pacing Clin Electrophysiol ; 43(2): 234-239, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31849077

RESUMEN

INTRODUCTION: Diaphragmatic myopotential oversensing (dMPO) by implantable cardioverter defibrillators (ICDs) is thought to be a rare condition that can be misdiagnosed as lead failure and lead to unnecessary lead replacement. We observed several cases of dMPO in patients with Sorin/LivaNova ICDs (MicroPort Sci.). We sought to systematically assess the incidence of dMPO in patients with Sorin/LivaNova ICDs. METHODS AND RESULTS: A predefined number of 100 consecutive patients with Sorin/LivaNova ICDs were prospectively included in the device clinic of our center. Stored arrhythmia episodes were checked for spontaneous dMPO. In addition, we performed provocation maneuvers by Valsalva. At least one episode of spontaneous or provoked dMPO was seen in 12 (12%) of the 100 patients included in the study (86% males, median age: 66 years). Nine of 89 patients (10%) with true bipolar and 3 of 11 patients (27%) with integrated bipolar sensing configuration were affected. Spontaneous dMPO was observed in 7 of 58 patients (12%) with sensitivity programmed to 0.4 mV and in 2 of 42 patients (5%) with sensitivity programmed to 0.6 mV (not significant). In three patients, dMPO could be provoked with no spontaneous episodes recorded. In two nonpacemaker-dependent patients with a CRT-D, ventricular pacing was temporarily inhibited. No antitachycardia therapy was triggered by dMPO in any patient. CONCLUSIONS: DMPO is frequent in patients with Sorin/LivaNova ICDs, especially with sensitivity programmed to 0.4 mV. It also frequently occurs with true bipolar sensing configuration. DMPO should not be misinterpreted as lead failure to avoid unnecessary lead replacement.


Asunto(s)
Desfibriladores Implantables , Diafragma/inervación , Diafragma/fisiopatología , Potenciales Evocados Motores/fisiología , Anciano , Errores Diagnósticos , Falla de Equipo , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sensibilidad y Especificidad , Maniobra de Valsalva/fisiología
16.
Europace ; 18(7): 994-9, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26462703

RESUMEN

AIMS: Pulmonary vein isolation (PVI) is an effective treatment option for paroxysmal atrial fibrillation (PAF). Reconnection of pulmonary veins (PVs) is the predominant cause for recurrence of PAF. However, treatment of patients with recurrence of PAF despite isolated PV in the absence of extra-PV foci remains challenging. METHODS AND RESULTS: Of 265 patients undergoing repeat catheter ablation (CA) for recurrence of PAF 21 (8%) patients (14 men, age 58 ± 14 years) showed no reconnection of PV. Therefore, inducibility of sustained atrial arrhythmias was tested. If sustained atrial fibrillation (AF) or sustained atrial tachycardia (AT) was induced, patients underwent CA. During follow-up (FU), Holter- and Tele-electrocardiogram were performed. In 19 (91%) of 21 patients, sustained atrial arrhythmias [16 (84%) AF; 3 (15%) patients AT] were induced. One patient showed PAF. Eighteen patients underwent CA aiming for termination of induced arrhythmia. In 14 (77%) patients, termination into sinus rhythm was achieved. Despite extensive CA, three (16%) patients were externally cardioverted. No periprocedural complications occurred. During 21.2 ± 6.8-month FU, 10 (53%) patients were free of any arrhythmia. Paroxysmal atrial fibrillation recurred in 4 (21%) and AT in 5 (26%) patients. One patient showed persistent AF. Repeat CA was scheduled and successfully performed for these patients. CONCLUSION: In patients with recurrence of PAF despite isolated PV, termination of induced atrial arrhythmias can be achieved in most patients by defragmentation and AT ablation. Moreover, this ablation strategy results in favourable mid-term outcome results.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Taquicardia/epidemiología , Adulto , Anciano , Ablación por Catéter/efectos adversos , Cardioversión Eléctrica , Electrocardiografía , Femenino , Alemania , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
17.
Europace ; 18(8): 1245-51, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27247017

RESUMEN

AIMS: Propofol sedation has been shown to be safe for atrial fibrillation ablation and internal cardioverter-defibrillator implantation but its use for catheter ablation (CA) of ventricular tachycardia (VT) has yet to be evaluated. Here, we tested the hypothesis that VT ablation can be performed using propofol sedation administered by trained nurses under a cardiologist's supervision. METHODS AND RESULTS: Data of 205 procedures (157 patients, 1.3 procedures/patient) undergoing CA for sustained VT under propofol sedation were analysed. The primary endpoint was change of sedation and/or discontinuation of propofol sedation due to side effects and/or haemodynamic instability. Propofol cessation was necessary in 24 of 205 procedures. These procedures (Group A; n = 24, 11.7%) were compared with those with continued propofol sedation (Group B; n = 181, 88.3%). Propofol sedation was discontinued due to hypotension (n = 22; 10.7%), insufficient oxygenation (n = 1, 0.5%), or hypersalivation (n = 1, 0.5%). Procedures in Group A were significantly longer (210 [180-260] vs. 180 [125-220] min, P = 0.005), had a lower per hour propofol rate (3.0 ± 1.2 vs. 3.8 ± 1.2 mg/kg of body weight/h, P = 0.004), and higher cumulative dose of fentanyl administered (0.15 [0.13-0.25] vs. 0.1 [0.05-0.13] mg, P < 0.001), compared with patients in Group B. Five (2.4%) adverse events occurred. CONCLUSION: Sedation using propofol can be safely performed for VT ablation under the supervision of cardiologists. Close haemodynamic monitoring is required, especially in elderly patients and during lengthy procedures, which carrying a higher risk for systolic blood pressure decline.


Asunto(s)
Ablación por Catéter/métodos , Hipnóticos y Sedantes/administración & dosificación , Midazolam/uso terapéutico , Propofol/administración & dosificación , Taquicardia Ventricular/terapia , Anciano , Presión Sanguínea/efectos de los fármacos , Cardiólogos , Desfibriladores Implantables , Femenino , Alemania , Humanos , Hipotensión/inducido químicamente , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
18.
Heart Vessels ; 31(10): 1669-75, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26546306

RESUMEN

Catheter ablation of complex fractionated atrial electrograms (CFAE), also known as defragmentation ablation, may be considered for the treatment of persistent atrial fibrillation (AF) beyond pulmonary vein isolation (PVI). Concomitant antiarrhythmic drug (AAD) therapy is common, but the relevance of AAD administration and its optimal timing during ablation remain unclear. Therefore, we investigated the use and timing of AADs during defragmentation ablation and their possible implications for AF termination and ablation success in a large cohort of patients. Retrospectively, we included 200 consecutive patients (age: 61 ± 12 years, LA diameter: 47 ± 8 mm) with persistent AF (episode duration 47 ± 72 weeks) who underwent de novo ablation including CFAE ablation. In all patients, PVI was performed prior to CFAE ablation. The use and timing of AADs were registered. The follow-ups consisted of Holter ECGs and clinical visits. Termination of AF was achieved in 132 patients (66 %). Intraprocedural AADs were administered in 168/200 patients (84 %) 45 ± 27 min after completion of PVI. Amiodarone was used in the majority of the patients (160/168). The timing of AAD administration was predicted by the atrial fibrillation cycle length (AFCL). At follow-up, 88 patients (46 %) were free from atrial arrhythmia. Multivariate logistic regression analysis revealed that administration of AAD early after PVI, LA size, duration of AF history, sex and AFCL were predictors of AF termination. The administration of AAD and its timing were not predictive of outcome, and age was the sole independent predictor of AF recurrence. The administration of AAD during ablation was common in this large cohort of persistent AF patients. The choice to administer AAD therapy and the timing of the administration during ablation were influenced by AFCL, and these factors did not significantly influence the moderate single procedure success rate in this retrospective analysis.


Asunto(s)
Amiodarona/administración & dosificación , Antiarrítmicos/administración & dosificación , Fibrilación Atrial/terapia , Ablación por Catéter , Sistema de Conducción Cardíaco/fisiopatología , Venas Pulmonares/cirugía , Anciano , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Estudios Retrospectivos , Resultado del Tratamiento
20.
Heart Rhythm O2 ; 5(5): 257-265, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38840763

RESUMEN

Background: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology. Its potential value for repeat procedures after unsuccessful thermal ablation for atrial fibrillation has not been assessed. Objective: The purpose of this study was to summarize our initial experience with patients undergoing repeat procedures using PFA. Methods: Consecutive patients with arrhythmia recurrences after a prior thermal ablation undergoing a repeat procedure using a multipolar PFA catheter from May 2021 and December 2022 were included. After 3-dimensional electroanatomic mapping, reconnected pulmonary veins (PVs) were reisolated and veins with only ostial isolation wither ablated to widen antral PV isolation. Posterior wall ablation was performed if all PVs were durably isolated or in case of low-voltage areas on the posterior wall at the discretion of the operator. Patients underwent follow-up with 7-day Holter electrocardiography after 3, 6, and 12 months. Results: A total of 186 patients undergoing a repeat procedure using PFA were included. The median number of previous ablations was 1 (range 1-6). The prior ablation modality was radiofrequency in 129 patients (69.4%), cryoballoon in 51 (27.4%), and epicardial ablation in 6 (3.2%). At the beginning of the procedure, 258 of 744 PVs (35%) showed reconnections. Additional antral ablations were applied in 236 of 486 still isolated veins (49%). Posterior wall ablation was added in 125 patients (67%). Major complications occurred in 1 patient (transient ischemic attack 0.5%). Freedom from arrhythmia recurrence in Kaplan-Meier-analysis was 78% after 6 months and 54% after 12 months. Conclusion: PFA is a versatile and safe option for repeat procedures after failed prior thermal ablation.