Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Vet Radiol Ultrasound ; 58(5): 598-606, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28444825

RESUMEN

Understanding the normal course and optimizing visualization of the canine peripheral nerves of the lumbar plexus, in particular the sciatic and the femoral nerves, is essential when interpreting images of patients with suspected peripheral neuropathies such as inflammatory or neoplastic conditions. The purpose of this prospective, anatomic study was to describe the magnetic resonance imaging (MRI) anatomy of the normal canine femoral and sciatic nerves and to define the sequences in which the nerves are best depicted. A preliminary postmortem cadaver study was performed to determine optimal sequences and imaging protocol. In a second step the optimized technique was implemented on 10 healthy Beagle dogs, included in the study. The applied protocol included the following sequences: T1-weighted, T2-weighted, T2-Spectral Attenuated Inversion Recovery, T1-weighted postcontrast and T1-Spectral Presaturated Inversion Recovery postcontrast. All sequences had satisfactory signal-to-noise ratio and contrast resolution in all patients. The sciatic and femoral nerves were seen in all images. They were symmetric and of homogeneous signal intensity, being iso- to mildly hyperintense to muscle on T2-weighted, mildly hyperintense in T2-Spectral Attenuated Inversion Recovery, and iso- to mildly hypointense in T1-weighted images. No evidence of contrast enhancement in T1-weighted and T1-Spectral Presaturated Inversion Recovery postcontrast sequences was observed. The anatomic landmarks helpful to identify the course of the femoral and sciatic nerves are described in detail. This study may be used as an anatomical reference, depicting the normal canine femoral and sciatic nerves at 3 Tesla MRI.


Asunto(s)
Nervio Femoral/diagnóstico por imagen , Imagen por Resonancia Magnética/veterinaria , Nervio Ciático/diagnóstico por imagen , Animales , Cadáver , Perros , Femenino , Imagen por Resonancia Magnética/métodos , Masculino , Estudios Prospectivos , Valores de Referencia , Relación Señal-Ruido
2.
Vet Radiol Ultrasound ; 58(1): 53-61, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27714889

RESUMEN

In vivo diagnosis of tick-borne encephalitis is difficult due to high seroprevalence and rapid viral clearance, limiting detection of antibodies in blood and cerebrospinal fluid. Magnetic resonance imaging (MRI) characteristics of tick-borne encephalitis have been reported, however MRI studies can also be negative despite the presence of neurologic signs. Magnetic resonance spectroscopy (1 H MRS) is an imaging method that provides additional information about the metabolic characteristics of brain tissues. The purpose of this retrospective cross-sectional study was to describe brain metabolites using short echo time single-voxel 1 H MRS in dogs with confirmed tick-borne encephalitis and compare them with healthy dogs. Inclusion criteria for the affected dogs were neurological symptoms suggestive of tick-borne encephalitis, previous endemic stay and tick-bite, diagnostic quality brain MRI and 1 H MRS studies, and positive antibody titers or confirmation of tick-borne encephalitis with necropsy. Control dogs were 10, clinically normal beagles that had been used in a previous study. A total of six affected dogs met inclusion criteria. All dogs affected with tick-borne encephalitis had 1 H MRS metabolite concentration alterations versus control dogs. These changes included mild to moderate decreases in N-acetyl aspartate and creatine peaks, and mild increases in glutamate/glutamine peaks. No lactate or lipid signal was detected in any dog. Myoinositol and choline signals did not differ between affected and control dogs. In conclusion, findings supported the use of 1 H MRS as an adjunctive imaging method for dogs with suspected tick-borne encephalitis and inconclusive conventional MRI findings.


Asunto(s)
Encéfalo/parasitología , Enfermedades de los Perros/diagnóstico por imagen , Encefalitis Transmitida por Garrapatas/veterinaria , Espectroscopía de Protones por Resonancia Magnética , Animales , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Estudios Transversales , Enfermedades de los Perros/parasitología , Perros , Encefalitis Transmitida por Garrapatas/diagnóstico por imagen , Encefalitis Transmitida por Garrapatas/parasitología , Femenino , Masculino , Valores de Referencia , Estudios Retrospectivos
3.
BMC Musculoskelet Disord ; 13: 32, 2012 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-22400715

RESUMEN

BACKGROUND: In the present study, 4 different metallic implant materials, either partly coated or polished, were tested for their osseointegration and biocompatibility in a pelvic implantation model in sheep. METHODS: Materials to be evaluated were: Cobalt-Chrome (CC), Cobalt-Chrome/Titanium coating (CCTC), Cobalt-Chrome/Zirconium/Titanium coating (CCZTC), Pure Titanium Standard (PTST), Steel, TAN Standard (TANST) and TAN new finish (TANNEW). Surgery was performed on 7 sheep, with 18 implants per sheep, for a total of 63 implants. After 8 weeks, the specimens were harvested and evaluated macroscopically, radiologically, biomechanically (removal torque), histomorphometrically and histologically. RESULTS: Cobalt-Chrome screws showed significantly (p = 0.031) lower removal torque values than pure titanium screws and also a tendency towards lower values compared to the other materials, except for steel. Steel screws showed no significant differences, in comparison to cobalt-chrome and TANST, however also a trend towards lower torque values than the remaining materials. The results of the fluorescence sections agreed with those of the biomechanical test. Histomorphometrically, there were no significant differences of bone area between the groups. The BIC (bone-to-implant-contact), used for the assessment of the osseointegration, was significantly lower for cobalt-chrome, compared to steel (p = 0.001). Steel again showed a lower ratio (p = 0.0001) compared to the other materials. CONCLUSION: This study demonstrated that cobalt-chrome and steel show less osseointegration than the other metals and metal-alloys. However, osseointegration of cobalt-chrome was improved by zirconium and/or titanium based coatings (CCTC, TANST, TAN, TANNEW) being similar as pure titanium in their osseointegrative behavior.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Tornillos Óseos/normas , Ensayo de Materiales/métodos , Metales/farmacología , Oseointegración/fisiología , Implantación de Prótesis/métodos , Animales , Artroplastia de Reemplazo de Cadera/métodos , Materiales Biocompatibles Revestidos/farmacología , Materiales Biocompatibles Revestidos/uso terapéutico , Femenino , Metales/uso terapéutico , Modelos Animales , Oveja Doméstica
4.
J Feline Med Surg ; 17(8): 733-6, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25228168

RESUMEN

A 5-year-old cat developed a recurrent haematoma in the right hindlimb after receiving an intramuscular injection. Cold packs and a compressive bandage were applied without success. The haematoma resolved initially but recurred twice within a week after conservative treatment. Contrast computed tomography was performed after the second recurrence. A large cavernous lesion was found craniolateral to the right stifle. The lesion was removed surgically. No recurrence occurred during a 5 month follow-up. On histopathology the lesion was characterised as a chronic expansive haematoma. To our knowledge, this type of lesion has not previously been described in a small animal.


Asunto(s)
Enfermedades de los Gatos/diagnóstico por imagen , Enfermedades de los Gatos/cirugía , Hematoma/veterinaria , Rodilla de Cuadrúpedos/cirugía , Animales , Gatos , Enfermedad Crónica , Hematoma/diagnóstico por imagen , Hematoma/cirugía , Tomografía Computarizada por Rayos X/veterinaria , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA