Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 103(4): 523-531, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38440914

RESUMEN

BACKGROUND: Percutaneous coronary intervention (PCI) is considered less safe in patients with reduced ejection fraction (EF), an impression based on older data. Whether the safety and durability of contemporary PCI are different in patients with reduced EF compared with normal EF patients is unknown. METHODS: Patients from the BIOFLOW II, IV and V clinical trials were grouped as normal EF (≥50%) and reduced EF (30%-50%). Using multivariable logistic regression and cox proportional hazards regression, we determined relations of EF category with procedural safety (a composite of cardiac death, myocardial infarction, stroke and urgent coronary artery bypass grafting within 30 days of PCI) and target lesion failure (TLF; comprising cardiac death, target vessel myocardial infarction, target vessel revascularization within 1 year of PCI) respectively. In sensitivity analyses, we regrouped patients into EF < 45% and ≥55% and repeated the aforementioned analyses. RESULTS: In 1685 patients with normal EF (mean age 65 years; 27% women; mean EF 61%) and 259 with low EF (mean age 64 years; 17% women; mean EF 41%), 101 safety and 148 TLF events occurred. Compared with patients in the normal EF group, those with reduced EF had neither a statistically significant higher proportion of safety events, nor a higher multivariable-adjusted risk for such events. Similarly, patients with reduced EF and normal EF did not differ in terms of TLF event proportions or multivariable-adjusted risk for TLF. The results were similar in sensitivity analyses with EF groups redefined to create a 10% between-group EF separation. CONCLUSION: PCI safety and durability outcomes are similar in patients with mild-moderately reduced EF and normal EF.


Asunto(s)
Infarto del Miocardio , Intervención Coronaria Percutánea , Disfunción Ventricular Izquierda , Humanos , Femenino , Anciano , Persona de Mediana Edad , Masculino , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento , Infarto del Miocardio/etiología , Puente de Arteria Coronaria/efectos adversos , Disfunción Ventricular Izquierda/etiología , Muerte
2.
Neth Heart J ; 31(12): 489-499, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37910336

RESUMEN

OBJECTIVE: The importance of revascularisation of significant coronary artery disease (CAD) in patients undergoing transcatheter aortic valve implantation (TAVI) is unclear. Despite the lack of randomised controlled trials comparing different revascularisation strategies, guidelines currently recommend percutaneous coronary intervention (PCI) in patients with significant proximal CAD undergoing TAVI. METHODS: In this systematic review and meta-analysis, a systematic search was conducted to identify studies comparing TAVI with and without PCI in patients with significant CAD on pre-TAVI coronary angiography. Endpoints were all-cause mortality, cardiac death, stroke, myocardial infarction and major bleeding. RESULTS: In total, 14 studies were included, involving 3838 patients, of whom 1806 (47%) underwent PCI before TAVI. All-cause mortality did not differ significantly between TAVI with and without preceding PCI at 30 days, 1 year and > 1 year. There were no significant differences in risk of cardiac death, stroke or myocardial infarction between the groups. However, TAVI performed with PCI resulted in a higher risk of major bleeding within 30 days after TAVI (odds ratio: 0.66; 95% confidence interval: 0.46-0.94). CONCLUSION: This systematic review and meta-analysis showed no significant differences in clinical outcomes between patients with concomitant significant CAD who were treated with TAVI with and without preceding PCI at both short- and long-term follow-up. However, there was a higher risk of major bleeding at 30 days in patients undergoing TAVI with preceding PCI. In the context of serious risk of bias in the included studies, results of randomised controlled trials are warranted.

3.
Am Heart J ; 235: 140-148, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33609498

RESUMEN

BACKGROUND: Newest generation drug-eluting stents combine biodegradable polymers with ultrathin stent platforms in order to minimize vessel injury and inflammatory response. Evidence from randomized controlled trials suggested that differences in stent design translate into differences in clinical outcome. The aim of the present study was to evaluate the safety and efficacy of ultrathin strut, biodegradable polymer sirolimus eluting stents (BP SES) compared with thin strut, durable polymer everolimus-eluting stents (DP EES) among patients undergoing percutaneous coronary intervention (PCI). METHODS: We pooled individual participant data from 5 randomized trials (NCT01356888, NCT01939249, NCT02389946, NCT01443104, NCT02579031) including a total of 5,780 patients, and performed a one-stage meta-analysis using a mixed effects Cox regression model. RESULTS: At a median duration of follow-up of 739 days (interquartile range 365-1,806 days), target-lesion failure occurred in 337 (10.3%) and 304 (12.2%) patients treated with BP SES and DP EES (HR 0.86, 95%CI 0.71-1.06, P = .16). There were no significant differences between BP SES and DP EES with regards to cardiac death (111 (3.4%) vs 102 (4.1%); HR 1.05, 95%CI 0.80-1.37, P = .73), target-vessel myocardial infarction (136 (4.1%) vs 126 (5.0%), HR 0.79, 95%CI 0.62-1.01, P = .061), and clinically-driven target-lesion revascularization (163 (5.0%) vs 147 (5.9%); HR 0.94, 95%CI 0.75-1.18, P = .61). The effect was consistent across major subgroups. In a landmark analysis, there was no significant interaction between treatment effect and timing of events. CONCLUSIONS: In this patient-level meta-analysis of 5 randomized controlled trials, BP SES were associated with a similar risk of target-lesion failure compared with DP EES among patients undergoing PCI. STUDY REGISTRATION: PROSPERO registry (CRD42018109098).


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Everolimus/farmacología , Intervención Coronaria Percutánea/métodos , Polímeros , Sirolimus/farmacología , Stents Liberadores de Fármacos , Humanos , Diseño de Prótesis , Factores de Riesgo , Resultado del Tratamiento
4.
Am Heart J ; 234: 42-50, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33422517

RESUMEN

BACKGROUND: In intermediate- and high-risk non-ST elevated acute coronary syndrome (NSTE-ACS) patients, a routine invasive approach is recommended. The timing of coronary angiography remains controversial. To assess whether an immediate (<3 hours) invasive treatment strategy would reduce infarct size and is safe, compared with an early strategy (12-24 hours), for patients admitted with NSTE-ACS while preferably treated with ticagrelor. METHODS: In this single-center, prospective, randomized trial an immediate or early invasive strategy was randomly assigned to patients with NSTE-ACS. At admission, the patients were preferably treated with a combination of aspirin, ticagrelor and fondaparinux. The primary endpoint was the infarct size as measured by area under the curve (AUC) of CK-MB in 48 hours. Secondary endpoints were bleeding outcomes and major adverse cardiac events (MACE): composite of all-cause death, MI and unplanned revascularization. Interim analysis showed futility regarding the primary endpoint and trial inclusion was terminated. RESULTS: In total 249 patients (71% of planned) were included. The primary endpoint of in-hospital infarct size was a median AUC of CK-MB 186.2 ng/mL in the immediate group (IQR 112-618) and 201.3 ng/mL in the early group (IQR 119-479). Clinical follow-up was 1-year. The MACE-rate was 10% in the immediate and 10% in the early group (hazard ratio [HR] 1.13, 95% CI: 0.52-2.49). CONCLUSIONS: In NSTE-ACS patients randomized to either an immediate or an early-invasive strategy the observed median difference in the primary endpoint was about half the magnitude of the expected difference. The trial was terminated early for futility after 71% of the projected enrollment had been randomized into the trial.


Asunto(s)
Angiografía Coronaria , Infarto del Miocardio sin Elevación del ST/diagnóstico por imagen , Infarto del Miocardio sin Elevación del ST/terapia , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Anciano , Área Bajo la Curva , Aspirina/efectos adversos , Aspirina/uso terapéutico , Causas de Muerte , Terapia Combinada/métodos , Forma MB de la Creatina-Quinasa/sangre , Terminación Anticipada de los Ensayos Clínicos , Inhibidores del Factor Xa/efectos adversos , Inhibidores del Factor Xa/uso terapéutico , Femenino , Fondaparinux/efectos adversos , Fondaparinux/uso terapéutico , Humanos , Masculino , Inutilidad Médica , Infarto del Miocardio sin Elevación del ST/mortalidad , Infarto del Miocardio sin Elevación del ST/patología , Inhibidores de Agregación Plaquetaria/efectos adversos , Estudios Prospectivos , Ticagrelor/efectos adversos , Ticagrelor/uso terapéutico , Factores de Tiempo
5.
Catheter Cardiovasc Interv ; 98(5): 848-856, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-32890442

RESUMEN

OBJECTIVES: This analysis of pooled individual patient data (IPD) aimed to evaluate the safety and efficacy of a bioresorbable polymer sirolimus eluting stent system (BP-SES; Orsiro) compared to a durable polymer everolimus eluting stent system (DP-EES; Xience) in the pooled population as well as in subgroups. METHODS: IPD with up to 12 months follow-up of the randomized controlled trials BIOFLOW-II (NCT01356888), -IV (NCT01939249), and -V (NCT02389946) as well as the all comers registry BIOFLOW-III (NCT01553526) were pooled. A total of 3,717 subjects (2,923 in BP-SES and 794 in DP-EES) with 5,328 lesions (4,225 lesions in BP-SES and 1,103 in DP-EES) were included in the IPD. The primary endpoint was target lesion failure (TLF) at 12 months follow-up. Subgroups analyzed included diabetes, age (≥65 years), gender, complex lesions (B2/C), small vessels (reference vessel diameter ≤2.75 mm), multivessel treatment, renal disease, and patients with acute coronary syndrome. RESULTS: Overall, TLF at 12 months was significantly lower with 5.2%in the BP-SES group versus 7.6% in the DP-EES group (p = .0098). Similarly, target vessel myocardial infarction (TV-MI) was 3.1 versus 5.7% (p = .0005). The rate of stent thrombosis was similar in both groups (0.004%). By regression analysis, an independent stent effect in favor of BP-SES was observed for TLF (p = .0043) and TV-MI (p = .0364) in small vessels. CONCLUSION: Results of this IPD analysis suggest that the BP-SES with ultrathin struts is as safe as and more efficacious than DP-EES in the overall cohort and especially in small vessels.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Everolimus , Sirolimus , Implantes Absorbibles , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Análisis de Datos , Stents Liberadores de Fármacos/efectos adversos , Everolimus/efectos adversos , Humanos , Polímeros , Diseño de Prótesis , Sirolimus/efectos adversos , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 98(5): E661-E667, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34263520

RESUMEN

OBJECTIVES: We aimed to explore the impact of time to percutaneous coronary intervention (PCI) (T2P) on 1-year mortality in non-ST-elevation myocardial infarction (NSTEMI) patients. BACKGROUND: The current guidelines recommend an early invasive strategy for NSTEMI patients. However, impact of an early invasive strategy on mortality is a matter of debate. For that reason, real world data are of great value to determine the optimal treatment window. METHODS: This retrospective single center cohort study was performed in a high-volume PCI center in Amsterdam, The Netherlands. Intermediate- and high-risk NSTEMI patients undergoing PCI were included. The main discriminant was timing of PCI after admission (T2P), stratified according to different time windows (<24 h, 24-72 h, 72 h-7 days or >7 days). We analyzed 1-year mortality and the time distribution of overall survival. RESULTS: In total, 848 patients treated between January 1, 2016 and January 1, 2018 were included in the analysis. T2P was <24 h in 145 patients, 24-72 h in 192 patients, 72 h-7 days in 275 patients, and >7 days in 236 patients. The mean GRACE-risk score was 127.1 (SD 28.7), 130.0 (33.1), 133.8 (32.1), and 148.7 (34.6) respectively, p = <0.001. After adjusting for confounders, 1-year mortality in patients with T2P <24 h did not significantly differ when compared with T2P 24-72 h (OR = 1.08; 95% CI = 0.33-3.51) and T2P 72 h-7 days (OR 1.72; 95% CI = 0.57-5.21) but was significantly higher in T2P >7 days (OR = 3.20; 95% CI = 1.06-9.68). CONCLUSIONS: In an unselected cohort of patients with NSTEMI, treatment by PCI <24 h did not lead to improved survival as compared to aT2P <7 days strategy. Delay in PCI >7 days after admission resulted in worse outcome.


Asunto(s)
Infarto del Miocardio sin Elevación del ST , Intervención Coronaria Percutánea , Estudios de Cohortes , Humanos , Infarto del Miocardio sin Elevación del ST/diagnóstico por imagen , Infarto del Miocardio sin Elevación del ST/terapia , Estudios Retrospectivos , Resultado del Tratamiento
7.
Catheter Cardiovasc Interv ; 97(6): 1270-1278, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33347739

RESUMEN

OBJECTIVES: To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers. BACKGROUND: The MANTA is a novel plug-based device for large bore arteriotomy closure. METHODS: We included all eligible patients who underwent transfemoral large bore percutaneous procedures. Exclusion criteria were per operator's discretion and included severe calcification or marked tortuosity of the access vessel, presence of marked obesity/cachexia or a systolic blood pressure above 180 mmHg. The primary performance endpoint was time to hemostasis. Primary and secondary safety endpoints were major and minor access site related vascular complications up to 30 days, respectively. Vascular complications were adjudicated by an independent clinical event committee according to VARC-2 criteria. We performed multivariable logistic regression to estimate the effect of baseline and procedural characteristics on any and major vascular complications. RESULTS: Between February 2018 and July 2019 500 patients were enrolled undergoing Transcatheter aortic valve replacement (TAVR, N = 496), Balloon aortic valvuloplasty (BAV, N = 2), Mechanical circulatory support (MCS, N = 1) or Endovascular aneurysm repair (EVAR, N = 1). Mean age was 80.8 ± 6.6 years with a median STS-score of 2.7 [IQR 2.0-4.3] %. MANTA access site complications were major in 20 (4%) and minor in 28 patients (5.6%). Median time to hemostasis was 50 [IQR 20-120] sec. Severe femoral artery calcification, scar presence in groin, longer procedure duration, female gender and history of hypertension were independent predictors for vascular complications. CONCLUSION: In this study, MANTA appeared to be a safe and effective device for large bore access closure under real-world conditions.


Asunto(s)
Aneurisma de la Aorta Abdominal , Estenosis de la Válvula Aórtica , Implantación de Prótesis Vascular , Cateterismo Periférico , Procedimientos Endovasculares , Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos de Cierre Vascular , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Periférico/efectos adversos , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Hemorragia/etiología , Técnicas Hemostáticas/efectos adversos , Humanos , Sistema de Registros , Resultado del Tratamiento
8.
Cardiovasc Diabetol ; 19(1): 179, 2020 10 16.
Artículo en Inglés | MEDLINE | ID: mdl-33066794

RESUMEN

BACKGROUND: Patients with both diabetes mellitus (DM) and chronic kidney disease (CKD) are a subpopulation characterized by ultrahigh ischemic and bleeding risk after percutaneous coronary intervention. There are limited data on the impact of ticagrelor monotherapy among these patients. METHODS: In this post hoc analysis of the GLOBAL-LEADERS trial, the treatment effects of the experimental (one-month dual-antiplatelet therapy [DAPT] followed by 23-month ticagrelor monotherapy) versus the reference regimen (12-month DAPT followed by 12-month aspirin alone) were analyzed according to DM/CKD status. The primary endpoint was a composite endpoint of all-cause death or new Q-wave myocardial infarction at 2-years. The patient-oriented composite endpoint (POCE) was defined as the composite of all-cause death, any stroke, site-reported MI and any revascularization, whereas net adverse clinical events (NACE) combined POCE with BARC type 3 or 5 bleeding events. RESULTS: At 2 years, the DM + /CKD + patients had significantly higher incidences of the primary endpoint (9.5% versus 3.1%, adjusted HR 2.16; 95% CI [1.66-2.80], p < 0.001), BARC type 3 or 5 bleeding events, stroke, site-reported myocardial infraction, all revascularization, POCE, and NACE, compared with the DM-/CKD- patients. Among the DM + /CKD + patients, after adjustment, there were no significant differences in the primary endpoints between the experimental and reference regimen; however, the experimental regimen was associated with lower rates of POCE (20.6% versus 25.9%, HR 0.74; 95% CI [0.55-0.99], p = 0.043, pinteraction = 0.155) and NACE (22.7% versus 28.3%, HR 0.75; 95% CI [0.56-0.99], p = 0.044, pinteraction = 0.310), which was mainly driven by a lower rate of all revascularization, as compared with the reference regimen. The landmark analysis showed that while the experimental and reference regimen had similar rates of all the clinical endpoints during the first year, the experimental regimen was associated with significantly lower rates of POCE (5.8% versus 11.0%, HR 0.49; 95% CI [0.29-0.82], p = 0.007, pinteraction = 0.040) and NACE (5.8% versus 11.2%, HR 0.48; 95% CI [0.29-0.82], p = 0.007, pinteraction = 0.013) in the second year. CONCLUSION: Among patients with both DM and CKD, ticagrelor monotherapy was not associated with lower rates of all-cause death or new Q-wave, or major bleeding complications; however, it was associated with lower rates of POCE and NACE. These findings should be interpreted as hypothesis-generating. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov (NCT01813435).


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Diabetes Mellitus , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/uso terapéutico , Insuficiencia Renal Crónica , Ticagrelor/uso terapéutico , Anciano , Anciano de 80 o más Años , Asia , Australia , Brasil , Canadá , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidad , Stents Liberadores de Fármacos , Europa (Continente) , Femenino , Hemorragia/inducido químicamente , Hemorragia/mortalidad , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/mortalidad , Inhibidores de Agregación Plaquetaria/efectos adversos , Prevalencia , Ensayos Clínicos Controlados Aleatorios como Asunto , Recurrencia , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/mortalidad , Medición de Riesgo , Factores de Riesgo , Prevención Secundaria , Accidente Cerebrovascular/mortalidad , Accidente Cerebrovascular/prevención & control , Ticagrelor/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
9.
Lancet ; 392(10153): 1117-1126, 2018 09 29.
Artículo en Inglés | MEDLINE | ID: mdl-30190206

RESUMEN

BACKGROUND: The FIREHAWK is a drug-eluting stent with a fully biodegradable sirolimus-containing polymer coating localised to recessed abluminal grooves on the stent surface. We investigated clinical outcomes with this targeted, low-dose, biodegradable polymer, sirolimus-eluting stent compared with XIENCE durable polymer, everolimus-eluting stents in an all-comers population. METHODS: The TARGET All Comers study was a prospective, multicentre, open-label randomised non-inferiority trial done at 21 centres in ten European countries. Patients with symptomatic or asymptomatic coronary artery disease and objective evidence of myocardial ischaemia who qualified for percutaneous coronary intervention were randomised 1:1 to undergo implantation of a FIREHAWK or XIENCE. Randomisation was web-based, with random block allocation and stratification by centre and ST elevation myocardial infarction. Outcome assessors were masked to treatment allocation, but treating physicians and patients were not. The primary endpoint was target lesion failure at 12 months, a composite of cardiac death, target vessel myocardial infarction, or ischaemia-driven target lesion revascularisation. The control event rate for XIENCE was assumed to be 7%, the non-inferiority margin was 3.5%, and the primary analysis was in the intention-to-treat population, censoring patients who did not have either an event before 365 days or contact beyond 365 days. Late lumen loss was the primary endpoint of an angiographic substudy designed to investigate the non-inferiority of the FIREHAWK compared with the XIENCE stent. This trial is registered with ClinicalTrials.gov, number NCT02520180. FINDINGS: From Dec 17, 2015, to Oct 14, 2016, 1653 patients were randomly assigned to implantation of the FIREHAWK (n=823) or XIENCE (n=830). 65 patients in the FIREHAWK group and 66 in the XIENCE group had insufficient follow-up data and were excluded from the analyses. At 12 months, target lesion failure occurred in 46 (6·1%) of 758 patients in the FIREHAWK group and in 45 (5·9%) of 764 patients in the XIENCE group (difference 0·2%, 90% CI -1·9 to 2·2, pnon-inferiority=0·004, 95% CI -2·2 to 2·6, psuperiority=0·88). There were no differences in ischaemia-driven revascularisation or stent thrombosis rates at 12 months. 176 patients were included in the angiographic substudy, in which in-stent late lumen loss was 0·17 mm (SD 0·48) in the FIREHAWK group and 0·11 mm (0·52) in the XIENCE group (p=0·48), with an absolute difference of 0·05 mm (95% CI -0·09 to 0·18, pnon-inferiority=0·024). INTERPRETATION: In a broad all-comers population of patients requiring stent implantation for myocardial ischaemia, the FIREHAWK was non-inferior to the XIENCE as assessed with the primary endpoint of target lesion failure at 12 months and in-stent late lumen loss at 13 months. The FIREHAWK is a safe and effective alternative stent to treat patients with ischaemic coronary artery disease in clinical practice. FUNDING: Shanghai Microport Medical.


Asunto(s)
Implantes Absorbibles , Stents Liberadores de Fármacos , Inmunosupresores/administración & dosificación , Isquemia Miocárdica/cirugía , Sirolimus/administración & dosificación , Anciano , Estudios de Equivalencia como Asunto , Everolimus/administración & dosificación , Femenino , Humanos , Análisis de Intención de Tratar , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento
10.
Lancet ; 392(10151): 940-949, 2018 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-30166073

RESUMEN

BACKGROUND: We hypothesised that ticagrelor, in combination with aspirin for 1 month, followed by ticagrelor alone, improves outcomes after percutaneous coronary intervention compared with standard antiplatelet regimens. METHODS: GLOBAL LEADERS was a randomised, open-label superiority trial at 130 sites in 18 countries. Patients undergoing percutaneous coronary intervention with a biolimus A9-eluting stent for stable coronary artery disease or acute coronary syndromes were randomly assigned (1:1) to 75-100 mg aspirin daily plus 90 mg ticagrelor twice daily for 1 month, followed by 23 months of ticagrelor monotherapy, or standard dual antiplatelet therapy with 75-100 mg aspirin daily plus either 75 mg clopidogrel daily (for patients with stable coronary artery disease) or 90 mg ticagrelor twice daily (for patients with acute coronary syndromes) for 12 months, followed by aspirin monotherapy for 12 months. Randomisation was concealed, stratified by centre and clinical presentation (stable coronary artery disease vs acute coronary syndrome), and blocked, with randomly varied block sizes of two and four. The primary endpoint at 2 years was a composite of all-cause mortality or non-fatal centrally adjudicated new Q-wave myocardial infarction as assessed by a core lab in a blinded manner. The key secondary safety endpoint was site-reported bleeding assessed according to the Bleeding Academic Research Consortium criteria (grade 3 or 5). Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT01813435, and is closed to new participants, with follow-up completed. FINDINGS: Between July 1, 2013, and Nov 9, 2015, 15 968 participants were randomly assigned, 7980 to the experimental group and 7988 to the control group. At 2 years, 304 (3·81%) participants in the experimental group had died or had a non-fatal centrally adjudicated new Q-wave myocardial infarction, compared with 349 (4·37%) participants in the control group (rate ratio 0·87 [95% CI 0·75-1·01]; p=0·073]). There was no evidence for a difference in treatment effects for the primary endpoint across prespecified subgroups of acute coronary syndromes and stable coronary artery disease (p=0·93). Grade 3 or 5 bleeding occurred in 163 participants in the experimental group and 169 in the control group (2·04% vs 2·12%; rate ratio 0·97 [95% CI 0·78-1·20]; p=0·77). INTERPRETATION: Ticagrelor in combination with aspirin for 1 month followed by ticagrelor alone for 23 months was not superior to 12 months of standard dual antiplatelet therapy followed by 12 months of aspirin alone in the prevention of all-cause mortality or new Q-wave myocardial infarction 2 years after percutaneous coronary intervention. FUNDING: AstraZeneca, Biosensors, and The Medicines Company.


Asunto(s)
Adenosina/análogos & derivados , Aspirina/administración & dosificación , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio/mortalidad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Antagonistas del Receptor Purinérgico P2Y/administración & dosificación , Adenosina/administración & dosificación , Anciano , Clopidogrel , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/mortalidad , Quimioterapia Combinada , Stents Liberadores de Fármacos/efectos adversos , Femenino , Humanos , Análisis de Intención de Tratar , Masculino , Persona de Mediana Edad , Infarto del Miocardio/prevención & control , Intervención Coronaria Percutánea , Ticagrelor , Ticlopidina/administración & dosificación , Ticlopidina/análogos & derivados
11.
Catheter Cardiovasc Interv ; 93(7): 1255-1261, 2019 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-30489011

RESUMEN

OBJECTIVES: We aimed to evaluate the safety and efficacy of the dedicated Tryton side branch (SB) stent for the treatment of true bifurcations involving large SBs. BACKGROUND: Bifurcation lesions are associated with lower procedural success and a higher risk of adverse cardiac events. Provisional stenting (PS) is currently the default approach for the treatment of bifurcation lesions. The Tryton stent is a dedicated bifurcation stent system for the treatment of true bifurcation lesions. METHODS: We performed an individual-patient-data pooled post-hoc analysis of the Tryton Pivotal randomized controlled trial and post-approval Confirmatory Study. Only patients with true bifurcations involving a SB ≥ 2.25 mm in diameter were included. The primary endpoint was non-inferiority of Tryton compared with PS for target vessel failure (TVF) at 1 year. RESULTS: Of the 411 patients meeting the criteria for enrolment, 287 patients were treated with the Tryton stent and 124 with PS. Procedural success was higher in the Tryton group (95.4 versus 82.3%, P < 0.0001). TVF at 1 year was 8.1% in the Tryton group and 9.7% in the PS group, meeting the pre-specified criteria for non-inferiority established for the randomized controlled trail (pnon-inferiority = 0.02). At 9-month angiographic follow-up, SB diameter stenosis was significantly lower in the Tryton group (29.3 ± 21.9 versus 41.1 ± 17.5, P = 0.0008) and in-segment binary restenosis (diameter stenosis ≥ 50%) was higher in the PS group (19.0 versus 34.2%, respectively, P = 0.052). CONCLUSIONS: In patients with true bifurcations involving a large SB, treatment with the Tryton SD Stent was clinically non-inferior to PS and showed favorable angiographic outcomes.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea/instrumentación , Stents , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/etiología , Estudios de Equivalencia como Asunto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
Catheter Cardiovasc Interv ; 87(7): 1213-21, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26370515

RESUMEN

AIM: In primary percutaneous coronary intervention (PPCI) for ST-elevation myocardial infarction (STEMI), stenting has proved to reduce the need for repeat revascularization compared with balloon angioplasty alone. The incidence of cardiac death or recurrent myocardial infarction, though, is not reduced by stenting. This is in part attributable to stent-related complications like stent thrombosis which may occur even years after implantation. A strategy of drug coated balloon (DCB) angioplasty without stenting would abolish the potential disadvantages of stent implantation while reducing the probability of restenosis observed in plain old balloon angioplasty. Our aim is to evaluate the efficacy and safety of a DCB only strategy versus drug-eluting stents (DES) in PPCI for STEMI. STUDY DESIGN: The REVELATION trial is a prospective, single center, randomized study, in which 120 patients presenting with STEMI will be allocated to treatment with a DCB versus DES. Appertaining to the established prognostic value of fractional flow reserve (FFR) rather than angiographic lesion severity, the functional assessment of the infarct-related lesion by FFR at 9 months after initial treatment is the primary end point. Assuming an FFR value of 0.90 after stenting and an increased risk of adverse events if post-PCI FFR <0.85, we decided to accept an FFR value of ≥0.85 after DCB only at follow-up as noninferiority margin. Secondary end points include major adverse cardiac events up to 5-year follow-up. CONCLUSION: Our trial will address the efficacy and safety of DCB angioplasty versus DES in the setting of PPCI for STEMI. The REVELATION trial will introduce the recognized prognostic significance of physiologic assessment of the infarct-related lesion by FFR at 9 months follow-up as primary end point. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Infarto del Miocardio con Elevación del ST/terapia , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Cateterismo Cardíaco , Fármacos Cardiovasculares/efectos adversos , Protocolos Clínicos , Angiografía Coronaria , Reestenosis Coronaria/etiología , Ecocardiografía , Reserva del Flujo Fraccional Miocárdico , Humanos , Países Bajos , Paclitaxel/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , Recurrencia , Proyectos de Investigación , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/mortalidad , Infarto del Miocardio con Elevación del ST/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
13.
Catheter Cardiovasc Interv ; 87(7): 1231-41, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26397982

RESUMEN

OBJECTIVES: To examine the benefit of the Tryton dedicated side branch (SB) stent compared with provisional stenting in the treatment of complex bifurcation lesions involving large SBs. BACKGROUND: The TRYTON Trial was designed to evaluate the utility of a dedicated SB stent to treat true bifurcation lesions involving large (≥2.5 mm by visual estimation) SBs. Patient enrolled in the trial had smaller SB diameters than intended (59% SB ≤2.25 mm by Core Lab QCA). The TRYTON Trial did not meet its primary endpoint due to an increased rate of peri-procedural myocardial infarctions (MIs). METHODS: The TRYTON Trial randomized 704 patients to the Tryton SB stent with main vessel DES versus provisional SB treatment with main vessel DES. The rates of the primary end point of target vessel failure and the secondary powered end point of angiographic percent diameter stenosis in the SB at 9 months were assessed and compared between the two treatment strategies among patients with a SB ≥2.25 mm diameter at baseline determined by Core Lab QCA. RESULTS: Among the 704 patients enrolled in the TRYTON Trial, 289 patients (143 provisional and 146 Tryton stent; 41% of entire cohort) had a SB ≥2.25 mm. The primary end point of TVF was numerically lower in the Tryton group compared with the provisional group (11.3% vs. 15.6%, P = 0.38), and was within the non-inferiority margin. No difference among the rates of clinically driven target vessel revascularization (3.5% vs. 4.3% P = 0.77) or cardiac death (0% both groups) were seen. In-segment percent diameter stenosis of the SB was significantly lower in the Tryton group compared with the provisional group (30.4% vs. 40.6%, P = 0.004). CONCLUSIONS: Analysis of the TRYTON Trial cohort of SB ≥2.25 mm supports the safety and efficacy of the Tryton SB stent compared with a provisional stenting strategy in the treatment of bifurcation lesions involving large SBs. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Stents , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Trombosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento
14.
Catheter Cardiovasc Interv ; 86 Suppl 1: S28-33, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25754236

RESUMEN

AIMS: We sought to evaluate the procedural and clinical performances of the MGuard Prime Embolic Protection Stent (EPS) in a "real-world" population with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PPCI). METHODS AND RESULTS: Consecutive STEMI patients meeting the inclusion criteria and undergoing PPCI were enrolled. The primary endpoint was major adverse cardiac events (MACE) at 30 days, defined as the composite of cardiac death, myocardial infarction (Q wave and non-Q wave) or target lesion revascularization (PCI or coronary artery bypass graft). Secondary endpoints included device success, lesion success, and postprocedural reperfusion outcomes: thrombolysis in myocardial infarction (TIMI) flow and ST-segment elevation resolution (STR). A total of 97 patients (62 years, 77% men) were included. Symptom to cathlab time was 238 min. Device and lesion success were 100%. Final TIMI-3 flow was achieved in 91.8%, and STR > 50% in 87% of the patients. MACE at 30 days was 2.2%, which consisted of one case each of target vessel (TV)-myocardial infarction (MI), and non-TV-MI. CONCLUSIONS: The use of the MGuard Prime EPS stent is feasible and safe and could be also effective in achieving myocardial reperfusion in STEMI patients undergoing PPCI.


Asunto(s)
Electrocardiografía , Dispositivos de Protección Embólica , Embolia/prevención & control , Infarto del Miocardio/cirugía , Intervención Coronaria Percutánea/métodos , Vigilancia de Productos Comercializados/métodos , Stents , Angiografía Coronaria , Estudios de Seguimiento , Humanos , Infarto del Miocardio/diagnóstico por imagen , Complicaciones Posoperatorias/prevención & control , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento
15.
J Interv Cardiol ; 28(6): 523-30, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26643000

RESUMEN

OBJECTIVES: Our aim was to investigate the risk of events related to non-culprit lesions after primary percutaneous coronary intervention (PCI) in patients with multivessel coronary disease (MVD). BACKGROUND: In patients undergoing primary PCI for ST-elevation myocardial infarction (STEMI) who are diagnosed with MVD, the optimal treatment strategy is currently under debate. Although observational data exposed an increased risk of multivessel PCI in the acute phase of STEMI, 2 recently published randomized controlled trials showed a reduction of death or recurrent myocardial infarction (MI) after preventive PCI of non-culprit lesions when compared with culprit-lesion PCI only. METHODS: We performed a post-hoc analysis of 279 patients with MVD included in the Paclitaxel-Eluting Stent versus Conventional Stent in Myocardial Infarction with ST-Segment Elevation (PASSION) trial. We analyzed the incidence and cause of recurrent MI. Recurrent MI due to stent failure was assumed in the event of definite or probable stent thrombosis. RESULTS: After 5 years, 14 patients (5.7%) with MVD had a recurrent MI versus 17 (5.4%) patients with 1-vessel disease (HR 1.06, 95%CI 0.52-2.15, P = 0.87). The majority of events was attributable to stent failure, while of the remaining 6 events, only 1 was proven to originate from a lesion that was judged significant at enrolment. CONCLUSIONS: In this post-hoc analysis of the PASSION trial, recurrent MI in patients with MVD was mainly related to stent failure rather than a new event originating from a significant stenosis in a non-culprit coronary artery.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Falla de Equipo , Infarto del Miocardio/epidemiología , Intervención Coronaria Percutánea , Anciano , Enfermedad de la Arteria Coronaria/complicaciones , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/terapia , Paclitaxel , Recurrencia
16.
Lancet ; 381(9867): 651-60, 2013 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-23374650

RESUMEN

BACKGROUND: Drug-eluting stents with durable biocompatible or biodegradable polymers have been developed to address the risk of thrombosis associated with first-generation drug-eluting stents. We aimed to compare the safety and efficacy of a biodegradable polymer-coated biolimus-eluting stent with a thin-strut everolimus-eluting stent coated with a durable biocompatible polymer. METHODS: This open-label, prospective, randomised, controlled, non-inferiority trial was undertaken at 12 sites across Europe. We used limited exclusion criteria (age >18 years, life expectancy >5 years, reference vessel diameter 2·0-4·0 mm) to enrol patients eligible for percutaneous coronary intervention. Patients were randomly allocated (2:1) by computer-generated random numbers to receive either a biodegradable polymer biolimus-eluting stent (Nobori, Terumo, Tokyo, Japan) or a durable fluoropolymer-based everolimus-eluting stent (Xience V or Prime, Abbott Vascular, Santa Clara, CA, USA, or Promus, Boston Scientific, Natick, MA, USA). The primary endpoint was a composite of safety (cardiac death and non-fatal myocardial infarction) and efficacy (clinically indicated target vessel revascularisation) at 12 months, analysed by intention to treat. Patients received dual antiplatelet therapy for 12 months after discharge. The trial is registered with ClinicalTrials.gov, number NCT01233453. FINDINGS: From Jan 12, 2009, to Feb 7, 2011, we enrolled 2707 patients (4025 lesions), 1795 of whom were assigned to receive the biolimus-eluting stent (2638 lesions) and 912 to an everolimus-eluting stent (1387 lesions). 2688 (99·3%) patients completed 12 months' follow-up. Significantly more patients in the biolimus-eluting stent group received a non-assigned stent than did those in the everolimus-eluting stent group (105 [5·9%] vs 19 [2·1%]; p<0·0001). The primary endpoint occurred in 93 (5·2%) patients in the biolimus-eluting stent group and 44 (4·8%) patients in the everolimus-eluting stent group at 12 months (relative risk 1·07 [95% CI 0·75-1·52]; p(non-inferiority)<0·0001). Analysis per protocol did not change the outcome of this trial (p(non-inferiority)<0·0001). INTERPRETATION: Biodegradable polymer biolimus-eluting stents are as safe and efficacious as the current standard of a thin-strut everolimus-eluting stent with a durable biocompatible polymer. We need to follow-up patients for longer to show whether the biolimus-eluting stent reduces the risk of stent thrombosis after 1 year when compared with the everolimus-eluting stent. FUNDING: Terumo Europe (Leuven, Belgium) and the Research Foundation of the Cardiology Department, Maasstad Hospital (Rotterdam, Netherlands).


Asunto(s)
Implantes Absorbibles , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Trombosis Coronaria/epidemiología , Stents Liberadores de Fármacos , Aspirina/uso terapéutico , Enfermedad de la Arteria Coronaria/mortalidad , Stents Liberadores de Fármacos/efectos adversos , Everolimus , Femenino , Humanos , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/uso terapéutico , Polímeros , Estudios Prospectivos , Sirolimus/análogos & derivados , Sirolimus/uso terapéutico
17.
Int J Cardiol ; 386: 24-29, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37178801

RESUMEN

BACKGROUND: Coronary artery calcification is a strong predictor for procedural failure and is independently associated with adverse events after percutaneous coronary intervention (PCI). An important contributor to the impaired outcome is the inability to achieve optimal results due to stent underexpansion or stent deformation/fracture. Intravascular lithotripsy (IVL) has emerged as an alternative technique to change the integrity of calcified plaques. AIMS: Our aim was to investigate if pre-treatment with IVL in severely calcified lesions increases stent expansion, assessed by optical coherence tomography (OCT), when compared to predilatation with conventional and/or specialty balloon strategy. METHODS: EXIT-CALC was a prospective, single-centre, randomised controlled study. Patients with an indication for PCI and severe calcification of the target lesion were allocated to predilatation with conventional angioplasty balloons or pre-treatment with IVL, followed by drug-eluting stenting and mandatory postdilatation. Primary endpoint was stent expansion assessed by OCT. Secondary endpoints were the occurrence of peri-procedural events and major adverse cardiac events (MACE) in hospital and during follow-up. RESULTS: A total of 40 patients were included. The minimal stent expansion in the IVL-group (n = 19) was 83.9 ± 10.3% and 82.2 ± 11.5% in the conventional group (n = 21) (p = 0.630). Minimal stent area was 6.6 ± 1.5 mm2 and 6.2 ± 1.8 mm2, respectively (p = 0.406). No peri-procedural, in-hospital and 30-day follow-up MACE were reported. CONCLUSIONS: In severely calcified coronary lesions we found no significant difference in stent expansion measured by OCT when comparing IVL, as plaque modification, with conventional and/or specialty angioplasty balloons.


Asunto(s)
Enfermedad de la Arteria Coronaria , Litotricia , Intervención Coronaria Percutánea , Calcificación Vascular , Humanos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Vasos Coronarios/patología , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/cirugía , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Stents , Litotricia/efectos adversos , Litotricia/métodos
18.
EuroIntervention ; 19(10): e844-e855, 2023 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-37860860

RESUMEN

BACKGROUND: In the prospective, multicentre, randomised TARGET All Comers study, percutaneous coronary intervention (PCI) with the FIREHAWK biodegradable-polymer sirolimus-eluting stent (BP-SES) was non-inferior to the durable-polymer everolimus-eluting stent (DP-EES) for the primary endpoint of target lesion failure (TLF) at 12 months. AIMS: We aimed to report the final study outcomes at 5 years. METHODS: Patients referred for PCI were randomised to receive either a BP-SES or DP-EES in a 1:1 ratio in 10 European countries. Randomisation was stratified by centre and ST-elevation myocardial infarction (STEMI) presentation, and clinical follow-up extended to 5 years. The primary endpoint was TLF (composite of cardiac death, target vessel myocardial infarction [MI], or ischaemia-driven target lesion revascularisation). Secondary endpoints included patient-oriented composite events (POCE; composite of all-cause death, all MI, or any revascularisation and its components). RESULTS: From December 2015 to October 2016, 1,653 patients were randomly assigned to the BP-SES or DP-EES groups, of which 93.8% completed 5-year clinical follow-up or were deceased. At 5 years, TLF occurred in 17.1% of the BP-SES group and in 16.3% of the DP-EES group (p=0.68). POCE occurred in 34.0% of the BP-SES group and 32.7% of the DP-EES group (p=0.58). Revascularisation was the most common POCE, occurring in 19.3% of patients receiving BP-SES and 19.2% receiving DP-EES, of which less than one-third was ischaemia-driven target lesion-related. In the landmark analysis, there were no differences in the rates of TLF and POCE between groups from 1 to 5 years, and these results were consistent across all subgroups. CONCLUSIONS: In an all-comers population requiring stent implantation for myocardial ischaemia, the BP-SES was non-inferior to the DP-EES for the primary endpoint of TLF at 12 months, and results were sustained at 5 years, confirming the long-term safety and efficacy of the FIREHAWK BP-SES.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Sirolimus , Stents Liberadores de Fármacos/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Implantes Absorbibles , Everolimus , Infarto del Miocardio/etiología , Polímeros
19.
Catheter Cardiovasc Interv ; 79(6): 870-7, 2012 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-21735533

RESUMEN

BACKGROUND: Although current clinical guidelines recommend the use of thrombus aspiration (TA) during primary percutaneous coronary intervention (PPCI), previous studies evaluating TA demonstrated contradictory results. The aim of this study was to evaluate long-term clinical outcome after TA in adjunct to PPCI for acute ST-segment myocardial infarction (STEMI), as compared with conventional treatment, with the use of paclitaxel-eluting stents or bare-metal stents. METHODS: We analyzed data of the PASSION trial, in which 619 patients with STEMI were randomly assigned to a paclitaxel-eluting stent or a bare-metal stent. TA was performed in 311 patients (50.2%). Clinical endpoints at 2 years were compared between patients who received TA during PPCI with patients who underwent conventional PPCI. The primary outcome of interest was a composite of cardiac death, recurrent myocardial infarction (MI), or target-lesion revascularization (TLR). A propensity score model was made to account for baseline differences that could have affected the probability of performing TA. RESULTS: Complete follow-up was available for 598 patients (96.6%). The cumulative incidence of the combined outcome measure of cardiac death, recurrent MI, or TLR was 40 (13.0%) in the TA group and 41 (13.5%) in the conventional PPCI group (HR 0.96; 95% CI 0.62-1.47; P = 0.84). Also after adjusting for propensity score, no significant difference in event rate was observed between both treatment groups. CONCLUSIONS: In this post-hoc analysis of the PASSION trial, TA in adjunct to PPCI did not affect rates of major adverse cardiac events at 2 years follow-up, as compared with conventional PPCI.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Stents Liberadores de Fármacos , Metales , Infarto del Miocardio/terapia , Paclitaxel/administración & dosificación , Stents , Trombectomía/métodos , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Distribución de Chi-Cuadrado , Angiografía Coronaria , Femenino , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/mortalidad , Países Bajos , Oportunidad Relativa , Puntaje de Propensión , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Succión , Trombectomía/efectos adversos , Trombectomía/mortalidad , Factores de Tiempo , Resultado del Tratamiento
20.
Eur Heart J ; 32(12): 1472-8, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20051425

RESUMEN

Aims Comparison of magnetic guidewire navigation in percutaneous coronary intervention (MPCI) vs. conventional percutaneous coronary intervention (CPCI) for the treatment of acute myocardial infarction. Methods and results We compared 65 sequential patients (mean age 61 ± 15 years) undergoing primary MPCI with those of 405 patients undergoing CPCI (mean age 61 ± 13 years). The major endpoint was contrast media use. Technical success and procedural outcomes were evaluated. Clinical demographics and angiographic characteristics of the two groups were similar, except for fewer patients with previous coronary artery bypass grafting (CABG) and hypertension in the CPCI group and fewer patients with diabetes in the MPCI group. The technical success rate was high in both the MPCI and CPCI groups (95.4 vs. 98%). There was significantly less contrast media usage in the MPCI compared with the CPCI group, median reduction of contrast media of 30 mL with an OR = 0.41 (0.21-0.81). Fluoroscopy times were significantly reduced for MPCI compared with CPCI, median reduction of 7.2 min with an OR = 0.42 (0.20-0.79). Conclusion This comparison indicates the feasibility and non-inferiority of magnetic navigation in performing primary PCI and suggests the possibility of reductions in contrast media use and fluoroscopy time compared with CPCI.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Magnetismo/métodos , Infarto del Miocardio/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/instrumentación , Estudios de Casos y Controles , Medios de Contraste , Diseño de Equipo , Estudios de Factibilidad , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA