Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 34(5): 1141-1151, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36808788

RESUMEN

INTRODUCTION: Preliminary data suggest that high power short duration (HPSD) ablation for pulmonary vein isolation (PVI) are safe. Limited data are available on its effectiveness. Aim was to evaluate HPSD ablation in atrial fibrillation ablation using a novel Qdot Micro catheter. METHODS AND RESULTS: Prospective multicenter study evaluating safety and efficacy of PVI with HPSD ablation. First pass isolation (FPI) and sustained PVI was assessed. If FPI was not achieved additional ablation index (AI)-guided ablation with 45 W was performed and metrics predictive of this were determined. Sixty-five patients and 260 veins were treated. Procedural and LA dwell time was 93.9 ± 30.4 and 60.5 ± 23.1 min, respectively. FPI was achieved in 47 (72.3%) patients and 231 veins (88.8%) with an ablation duration of 4.6 ± 1.0 min. Twenty-nine veins required additional AI-guided ablation to achieve initial PVI with 24 anatomical sites ablated with the right posterior carina being the most common site (37.5%). A contact force of ≥8 g (area under the curve [AUC]: 0.81; p < 0.001) and catheter position variation of ≤1.2 mm (AUC: 0.79; p < 0.001) with HPSD were strongly predictive of not requiring additional AI-guided ablation. Out of the 260 veins, only 5 (1.9%) veins showed acute reconnection. HPSD ablation was associated with shorter procedure times (93.9 vs. 159.4 min; p < 0.001), ablation times (6.1 vs. 27.7 min; p < 0.001), and lower rates of PV reconnection (9.2% vs. 30.8%; p = 0.004) compared to moderate power cohort. CONCLUSIONS: HPSD ablation is an effective ablation modality which results in effective PVI whilst maintaining a safety profile. Its superiority needs to be evaluated in randomized controlled trials.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Frecuencia Cardíaca , Venas Pulmonares/cirugía , Estudios Prospectivos , Catéteres , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento , Recurrencia
2.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37936325

RESUMEN

AIMS: Transvenous lead extraction (TLE) is important in the management of cardiac implantable electronic devices but carries risk. It is most commonly completed from the superior access, often with 'bail-out' support via the femoral approach. Superior and inferior access may be used in tandem, which has been proposed as an advance in safety and efficacy. The aim of this study is to evaluate the safety and efficacy of the Tandem approach. METHOD: The 'Tandem' procedure entailed grasping of the targeted lead in the right atrium to provide countertraction as a rotational dissecting sheath was advanced over the lead from the subclavian access. Consecutive 'Tandem' procedures performed by a single operator between December 2020 and March 2023 in a single large-volume TLE centre were included and compared with the conventional superior approach (control) using 1:1 propensity score matching; patients were statistically matched for demographics. RESULTS: The Tandem in comparison with the conventional approach extracted leads of much greater dwell time (148.9 ± 79 vs. 108.6 ± 77 months, P < 0.01) in a shorter procedure duration (96 ± 36 vs. 127 ± 67 min, P < 0.01) but requiring more fluoroscopy (16.4 ± 10.9 vs. 10.8 ± 14.9 min, P < 0.01). The Tandem and control groups had similar clinical (100% vs. 94.7%, P = 0.07) and complete (94.8% vs. 92.8%, P = 0.42) success, with comparable minor (4% vs. 6.7%, P = 0.72) and major (0% vs. 4%, P = 0.25) complications; procedural (0% vs. 1.3%, P = 1) and 30-day (1.3% vs. 4%, P = 0.62) mortality were also similar. CONCLUSION: The Tandem procedure is as safe and effective as the conventional TLE. It can be applied to leads of a long dwell time with a potentially shorter procedure duration.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/métodos , Factores de Tiempo , Fluoroscopía , Resultado del Tratamiento , Estudios Retrospectivos
3.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37882609

RESUMEN

AIMS: Transvenous lead extraction (TLE) is performed using non-laser and laser techniques with overall high efficacy and safety. Variation in outcomes between the two approaches does exist with limited comparative evidence in the literature. We sought to compare non-laser and laser TLE in a meta-analysis. METHODS AND RESULTS: We searched Medline, Embase, Scopus, ClinicalTrials.gov, and CENTRAL databases for TLE studies published between 1991 and 2021. From the included 68 studies, safety and efficacy data were carefully evaluated and extracted. Aggregated cases of outcomes were used to calculate odds ratio (OR), and pooled rates were synthesized from eligible studies to compare non-laser and laser techniques. Subgroup comparison of rotational tool and laser extraction was also performed. Non-laser in comparison with laser had lower procedural mortality (pooled rate 0% vs. 0.1%, P < 0.01), major complications (pooled rate 0.7% vs. 1.7%, P < 0.01), and superior vena cava (SVC) injury (pooled rate 0% vs. 0.5%, P < 0.001), with higher complete success (pooled rate 96.5% vs. 93.8%, P < 0.01). Non-laser comparatively to laser was more likely to achieve clinical [OR 2.16 (1.77-2.63), P < 0.01] and complete [OR 1.87 (1.69-2.08), P < 0.01] success, with a lower procedural mortality risk [OR 1.6 (1.02-2.5), P < 0.05]. In the subgroup analysis, rotational tool compared with laser achieved greater complete success (pooled rate 97.4% vs. 95%, P < 0.01) with lower SVC injury (pooled rate 0% vs. 0.7%, P < 0.01). CONCLUSION: Non-laser TLE is associated with a better safety and efficacy profile when compared with laser methods. There is a greater risk of SVC injury associated with laser sheath extraction.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Desfibriladores Implantables/efectos adversos , Vena Cava Superior/cirugía , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/métodos , Rayos Láser , Cateterismo Cardíaco , Marcapaso Artificial/efectos adversos , Resultado del Tratamiento , Estudios Retrospectivos
4.
J Cardiovasc Electrophysiol ; 33(6): 1262-1271, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35524414

RESUMEN

AIMS: To investigate the abnormalities of the coronary venous system in candidates for cardiac resynchronization therapy (CRT) and describe methods for circumventing the resulting difficulties. METHODS: From four implanting institutes, data of all CRT implants between October 2008 and October 2020 were screened for abnormal cardiac venous anatomy, defined as an anatomical variation not conforming to the accepted 'normal' anatomy. Patient demographics, procedural detail, and subsequent left ventricle (LV) lead pacing indices were collected. RESULTS: From a total of 3548 CRT implants, 15 (0.42%) patients (80% male) of 72.2 ± 10.6 years in age with an LV ejection fraction of 34 ± 10.3% were identified to have had an abnormal cardiac venous anatomy over the study period. There were 13 cases of persistent left side superior vena cava (pLSVC), five of which had coronary sinus ostium atresia (CSOA) including two with an "unroofed" coronary sinus (CS); one patient had a unique anomalous origin of the CS and one patient had an isolated CSOA. In total 14 patients (60% repeat attempt) had successful percutaneous implant under general anesthesia (46.7%) via the cephalic vein (59.1%), using the femoral approach (53.3%) for levophase venography and/or pull-through, including one case of endocardial LV implant. Pacing follow-up over 37.64 ± 37.6 months demonstrated LV lead threshold between 0.62 and 2.9 volts (pulsewidth 0.4-1.5 ms) in all cases; five patients died within 2.92 ± 1.6 years of a successful implant. CONCLUSION: CRT devices can be implanted percutaneously even in the presence of substantial abnormalities of coronary venous anatomy. Alternative routes of venous access may be required.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Vena Cava Superior Izquierda Persistente , Malformaciones Vasculares , Terapia de Resincronización Cardíaca/métodos , Dispositivos de Terapia de Resincronización Cardíaca , Drenaje , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Vena Cava Superior/anomalías , Vena Cava Superior/diagnóstico por imagen
5.
J Cardiovasc Electrophysiol ; 33(1): 102-108, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34783107

RESUMEN

BACKGROUND: Transvenous lead extraction (TLE) is rising in parallel to cardiac implantable electronic device implantations. Persistent left side superior vena cava (PLSVC) is a relatively common anatomical variant in the healthy population; TLE in patients with a PLSVC is rare. METHOD: Data were collated from 6 European TLE institutes of 10 patients who had undergone lead extraction with a PLSVC. Patient demographics, procedural challenges and outcomes were reported. RESULTS: Ten patients aged 73.4 ± 7.8 years (60% male) underwent TLE of 20 leads (3 left ventricle, 10 right ventricle, 7 right atrium) with dwell time of 82.95 ± 39.1 months. Of the 10 cases, 4 had an infection indication and 5 were biventricular system extractions; 25% of the extracted leads were defibrillator leads. The majority of the procedures were completed in the cardiac catheterization suite (80%) under general anaesthesia (60%) by cardiologists (80%) using a rotational powered sheath (65%). The Tandem approach was used successfully in 3 cases. Complete procedural success was obtained in 100% of cases in the absence of complications within 127.4 ± 74.7 min. There was no 30-day mortality. CONCLUSION: TLE in PLSVC is feasible albeit rare. Standard extraction techniques in experienced hands are associated with favorable outcomes; the Tandem procedure may be an additional technique to improve the safety and efficacy of TLE in PLSVC.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Vena Cava Superior Izquierda Persistente , Anciano , Anciano de 80 o más Años , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/métodos , Femenino , Humanos , Masculino , Marcapaso Artificial/efectos adversos , Resultado del Tratamiento , Vena Cava Superior/diagnóstico por imagen , Vena Cava Superior/cirugía
6.
J Cardiovasc Electrophysiol ; 33(12): 2546-2557, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36284450

RESUMEN

INTRODUCTION: The IMPACT study established the role of controlled esophageal cooling in preventing esophageal thermal injury during radiofrequency (RF) ablation for atrial fibrillation (AF). The effect of esophageal cooling on ablation lesion delivery and procedural and patient outcomes had not been previously studied. The objective was to determine the effect of esophageal cooling on the formation of RF lesions, the ability to achieve procedural endpoints, and clinical outcomes. METHODS: Participants in the IMPACT trial underwent AF ablation guided by Ablation Index (30 W at 350-400 AI posteriorly, 40 W at ≥450 AI anteriorly). A blinded 1:1 randomization assigned patients to the use of the ensoETM® device to keep esophageal temperature at 4°C during ablation or standard practice using a single-sensor temperature probe. Ablation parameters and clinical outcomes were analyzed. RESULTS: Procedural data from 188 patients were analyzed. Procedure and fluoroscopy times were similar, and all pulmonary veins were isolated. First-pass pulmonary vein isolation and reconnection at the end of the waiting period were similar in both randomized groups (51/64 vs. 51/68; p = 0.54 and 5/64 vs. 7/68; p = 0.76, respectively). Posterior wall isolation was also similar: 24/33 versus 27/38; p = 0.88. Ablation effect on tissue, measured in impedance drop, was no different between the two randomized groups: 8.6Ω (IQR: 6-11.8) versus 8.76Ω (IQR: 6-12.2; p = 0.25). Arrhythmia recurrence was similar after 12 months (21.1% vs. 24.1%; 95% CI: 0.38-1.84; HR: 0.83; p = 0.66). CONCLUSIONS: Esophageal cooling has been shown to be effective in reducing ablation-related thermal injury during RF ablation. This protection does not compromise standard procedural endpoints or clinical success at 12 months.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Resultado del Tratamiento , Atrios Cardíacos/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Recurrencia
7.
J Cardiovasc Electrophysiol ; 33(1): 7-16, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34797600

RESUMEN

INTRODUCTION: Before ablation, predicting the site of origin (SOO) of outflow tract ventricular arrhythmia (OTVA), can inform patient consent and facilitate appropriate procedural planning. We set out to determine if OTVA variability can accurately predict SOO. METHODS: Consecutive patients with a clear SOO identified at OTVA ablation had their prior 24-h ambulatory ECGs retrospectively analysed (derivation cohort). Percentage ventricular ectopic (VE) burden, hourly VE values, episodes of trigeminy/bigeminy, and the variability in these parameters were evaluated for their ability to distinguish right from left-sided SOO. Effective parameters were then prospectively tested on a validation cohort of consecutive patients undergoing their first OTVA ablation. RESULTS: High VE variability (coefficient of variation ≥0.7) and the presence of any hour with <50 VE, were found to accurately predict RVOT SOO in a derivation cohort of 40 patients. In a validation cohort of 29 patients, the correct SOO was prospectively identified in 23/29 patients (79.3%) using CoV, and 26/29 patients (89.7%) using VE < 50. Including current ECG algorithms, VE < 50 had the highest Youden Index (78), the highest positive predictive value (95.0%) and the highest negative predictive value (77.8%). CONCLUSION: VE variability and the presence of a single hour where VE < 50 can be used to accurately predict SOO in patients with OTVA. Accuracy of these parameters compares favorably to existing ECG algorithms.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Electrocardiografía , Ventrículos Cardíacos/cirugía , Humanos , Estudios Retrospectivos , Taquicardia Ventricular/cirugía
8.
Pacing Clin Electrophysiol ; 45(11): 1295-1298, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35687737

RESUMEN

A 39-years old ventricular lead of a right-sided single-chamber pacemaker required extraction for infection. Angulation at the right subclavian-superior vena cava junction coupled with calcified fibrotic encapsulating tissue prevented advancement of a rotational dissecting sheath. To straighten the lead, it was pulled from the subclavian and out of the right internal jugular vein, whilst the Needle's-Eye Snare via the femoral access provided counter-traction. A 13-french rotational dissecting sheath was successfully advanced over the lead via the jugular access to complete the lead extraction without any complication.


Asunto(s)
Marcapaso Artificial , Vena Cava Superior , Humanos , Adulto , Remoción de Dispositivos , Venas Yugulares/cirugía , Arteria Femoral
9.
Pacing Clin Electrophysiol ; 45(5): 658-665, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35417049

RESUMEN

BACKGROUND: With an increasing number of cardiac implantable electronic devices (CIEDs), there has been a paralleled increase in demand for transvenous lead extraction (TLE). Cardiac surgeons (CS) and cardiologists perform TLE; however, data comparing the two groups of operators is scarce. OBJECTIVE: We compared the outcomes of TLE performed by cardiologists and CS from six European lead extraction units. METHOD: Data was collected retrospectively of 2205 patients who had 3849 leads extracted (PROMET) between 2005 and 2018. Patient demographics and procedural outcomes were compared between the CS and cardiologist groups, using propensity score matching. A multivariate regression analysis was also performed for variables associated with 30-day mortality. RESULTS: CS performed the majority of extractions (59.8%), of leads with longer dwell times (90 [57-129 interquartile range (IQR)] vs. 62 [31-102 IQR] months, CS vs. cardiologists, p < .001) and with pre-dominantly non-infectious indications (57.4% vs. 50.2%, CS vs. cardiologists, p < .001). CS achieved a higher complete success per lead than the cardiologists (98.1% vs. 95.7%, respectively, p < .01), with a higher number of minor complications (5.51% vs. 2.1%, p < .01) and similar number of major complications (0.47% vs. 1.3%, p = .12). Thirty-day mortality was similarly low in the CS and cardiologist groups (1.76% vs. 0.94%, p = .21). Unmatched data multivariate analysis revealed infection indication (OR 6.12 [1.9-20.3], p < .01), procedure duration (OR 1.01 [1.01-1.02], p < .01) and CS operator (OR 2.67, [1.12-6.37], p = .027) were associated with 30-day mortality. CONCLUSION: TLE by CS was performed with similar safety and higher efficacy compared to cardiologists in high and medium-volume lead extraction centers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Remoción de Dispositivos/métodos , Humanos , Prometazina , Estudios Retrospectivos , Resultado del Tratamiento
10.
J Cardiovasc Electrophysiol ; 32(4): 1131-1139, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33565195

RESUMEN

BACKGROUND: Cardiac resynchronization therapy-defibrillator (CRT-D) implantation via the cephalic vein is feasible and safe. Recent evidence has suggested a higher implantable cardioverter-defibrillator (ICD) lead failure in multi-lead defibrillator therapy via the cephalic route. We evaluated the relationship between CRT-D implantation via the cephalic and ICD lead failure. METHODS: Data was collected from three CRT-D implanting centers between October 2008 and September 2017. In total 633 patients were included. Patient and lead characteristics with ICD lead failure were recorded. Comparison of "cephalic" (ICD lead via cephalic) versus "non-cephalic" (ICD lead via non-cephalic route) cohorts was performed. Kaplan-Meier survival and a Cox-regression analysis were applied to assess variables associated with lead failure. RESULTS: The cephalic and non-cephalic cohorts were equally male (81.9% vs. 78%; p = .26), similar in age (69.7 ± 11.5 vs. 68.7 ± 11.9; p = .33) and body mass index (BMI) (27.7 ± 5.1 vs. 27.1 ± 5.7; p = .33). Most ICD leads were implanted via the cephalic vein (73.5%) and patients had a mean of 2.9 ± 0.28 leads implanted via this route. The rate of ICD lead failure was low and statistically similar between both groups (0.36%/year vs. 0.13%/year; p = .12). Female gender was more common in the lead failure cohort than non-failure (55.6% vs. 17.9%, respectively; p = .004) as was hypertension (88.9% vs. 54.2%, respectively, p = .038). On multivariate Cox-regression, female sex (p = .008; HR, 7.12 [1.7-30.2]), and BMI (p = .047; HR, 1.12 [1.001-1.24]) were significantly associated with ICD lead failure. CONCLUSION: CRT-D implantation via the cephalic route is not significantly associated with premature ICD lead failure. Female gender and BMI are predictors of lead failure.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Hipertensión , Dispositivos de Terapia de Resincronización Cardíaca , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Resultado del Tratamiento
11.
Europace ; 23(2): 205-215, 2021 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-33205201

RESUMEN

AIMS: Thermal injury to the oesophagus is an important cause of life-threatening complication after ablation for atrial fibrillation (AF). Thermal protection of the oesophageal lumen by infusing cold liquid reduces thermal injury to a limited extent. We tested the ability of a more powerful method of oesophageal temperature control to reduce the incidence of thermal injury. METHODS AND RESULTS: A single-centre, prospective, double-blinded randomized trial was used to investigate the ability of the ensoETM device to protect the oesophagus from thermal injury. This device was compared in a 1:1 randomization with a control group of standard practice utilizing a single-point temperature probe. In the protected group, the device maintained the luminal temperature at 4°C during radiofrequency (RF) ablation for AF under general anaesthesia. Endoscopic examination was performed at 7 days post-ablation and oesophageal injury was scored. The patient and the endoscopist were blinded to the randomization. We recruited 188 patients, of whom 120 underwent endoscopy. Thermal injury to the mucosa was significantly more common in the control group than in those receiving oesophageal protection (12/60 vs. 2/60; P = 0.008), with a trend toward reduction in gastroparesis (6/60 vs. 2/60, P = 0.27). There was no difference between groups in the duration of RF or in the force applied (P value range= 0.2-0.9). Procedure duration and fluoroscopy duration were similar (P = 0.97, P = 0.91, respectively). CONCLUSION: Thermal protection of the oesophagus significantly reduces ablation-related thermal injury compared with standard care. This method of oesophageal protection is safe and does not compromise the efficacy or efficiency of the ablation procedure.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Esófago/cirugía , Humanos , Estudios Prospectivos , Temperatura , Resultado del Tratamiento
12.
Pacing Clin Electrophysiol ; 44(8): 1340-1346, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34240439

RESUMEN

BACKGROUND: The Sars-Cov-2 infection is a multisystem illness that can affect the cardiovascular system. Tachyarrhythmias have been reported but the prevalence of bradyarrhythmia is unclear. Cases have been described of transient high-degree atrioventricular (AV) block in COVID-19 that were managed conservatively. METHOD: A database of all patients requiring temporary or permanent pacing in two linked cardiac centers was used to compare the number of procedures required during the first year of the pandemic compared to the corresponding period a year earlier. The database was cross-referenced with a database of all patients testing positive for Sars-Cov-2 infection in both institutions to identify patients who required temporary or permanent pacing during COVID-19. RESULTS: The number of novel pacemaker implants was lower during the COVID-19 pandemic than the same period the previous year (540 vs. 629, respectively), with a similar proportion of high-degree AV block (38.3% vs. 33.2%, respectively, p = .069). Four patients with the Sars-Cov-2 infection had a pacemaker implanted for high-degree AV block, two for sinus node dysfunction. Of this cohort of six patients, two succumbed to the COVID-19 illness and one from non-COVID sepsis. Device interrogation demonstrated a sustained pacing requirement in all cases. CONCLUSION: High-degree AV block remained unaltered in prevalence during the COVID-19 pandemic. There was no evidence of transient high-degree AV block in patients with the Sars-Cov-2 infection. Our experience suggests that all clinically significant bradyarrhythmia should be treated by pacing according to usual protocols regardless of the COVID status.


Asunto(s)
Bradicardia/epidemiología , Bradicardia/terapia , COVID-19/complicaciones , Estimulación Cardíaca Artificial , Anciano , Anciano de 80 o más Años , Bradicardia/etiología , Humanos , Masculino , Prevalencia
13.
Pacing Clin Electrophysiol ; 44(4): 614-624, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33624296

RESUMEN

BACKGROUND: Cardiac implantable electronic device (CIED)-related perforation is uncommon but potentially lethal. Management typically includes the use of computed tomography (CT) scanning and often involves cardiac surgery. METHODS: Patients presenting to a single referral centre with CIED-related cardiac perforation between 2013 and 2019 were identified. Demographics, diagnostic modalities, the method of lead revision, and 30-day complications were examined. RESULTS: A total of 46 cases were identified; median time from implantation to diagnosis was 14 days (interquartile range = 4-50). Most were females (29/46, 63%), 9/46 (20%) had cancer, 18 patients (39%) used oral anticoagulants, and no patients had prior cardiac surgery. Active fixation was involved in 98% of cases; 9% involved an implantable cardioverter defibrillator lead. Thirty-seven leads perforated the right ventricle (apex: 24) and 9 punctured the right atrium (lateral wall: 5). Abnormal electrical parameters were noted in 95% of interrogated cases. Perforation was visualized in 41% and 6% of cases with chest X-ray (CXR) and transthoracic echocardiography, respectively. CXR revealed a perforation, gross lead displacement, or left-sided pleural effusion in 74% of cases. Pericardial effusion occurred in 26 patients (57%) of whom 11 (24%) developed tamponade, successfully drained percutaneously. Pre-extraction CT scan was performed in 19 patients but was essential in four cases. Transvenous lead revision (TLR) was successfully performed in all cases with original leads repositioned in six patients, without recourse to surgery. Thirty-day mortality and complications were low (0% and 26%, respectively). CONCLUSION: CT scanning provides incremental diagnostic value in a minority of CIED-related perforations. TLR is a safe and effective strategy.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/cirugía , Tomografía Computarizada por Rayos X , Anciano , Remoción de Dispositivos , Ecocardiografía , Femenino , Lesiones Cardíacas/etiología , Humanos , Masculino , Estudios Prospectivos , Reoperación , Factores de Riesgo
14.
Pacing Clin Electrophysiol ; 44(9): 1540-1548, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34235772

RESUMEN

BACKGROUND: Cardiac implantable electronic device (CIED) therapy contributes to an improvement in morbidity and mortality across all patient demographics. Patient age is a recognized risk factor for unfavorable outcomes in invasive procedures. This is the largest series of non-laser transvenous lead extraction (TLE) evaluating the association between patient age and procedure outcomes. METHODS: Data of 2205 (3849 leads) patients was collected retrospectively from six European TLE centers between January 2005-December 2018 in the PROMET study. Of these, 153 patients with 319 leads were excluded for incomplete data. A comparison of outcomes was performed between the age groups young [< 50 years], young intermediate [50-69 years], older intermediate [70-79 years], and octogenarian [≥80 years]. RESULTS: Infection was most common indication for TLE in the octogenarian cohort, less common in the younger population (60.1% vs. 33.2%, respectively, p < .01). High-voltage leads were extracted most frequently from young patients, less frequently from octogenarians (31.6% vs. 10%, p < .001), while the opposite was evident for pacemaker leads (p < .001). Rotational sheath use was equally prevalent across all patient groups (p = .79). Minor and major complications across all the age groups were statistically similar, as was procedural success; the 30-day mortality was most significant in the octogenarian and least in the young patients (4.9% vs. 0.4%, p = .005). Propensity matching multivariate analysis found systemic infection, lead dwell time, and patient age (p = .013, OR 1.064 [1.013-1.116]) increased risk of 30-day mortality. CONCLUSION: TLE is safe and effective across all age groups. 30-day mortality risk is significantly higher in the older patients.


Asunto(s)
Remoción de Dispositivos/métodos , Electrodos Implantados , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
15.
Europace ; 22(7): 1103-1110, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32447388

RESUMEN

AIMS: Several large studies have documented the outcome of transvenous lead extraction (TLE), focusing on laser and mechanical methods. To date there has been no large series addressing the results obtained with rotational lead extraction tools. This retrospective multicentre study was designed to investigate the outcomes of mechanical and rotational techniques. METHODS AND RESULTS: Data were collected on a total of 2205 patients (age 66.0 ± 15.7 years) with 3849 leads targeted for extraction in six European lead extraction centres. The commonest indication was infection (46%). The targeted leads included 2879 pacemaker leads (74.8%), 949 implantable cardioverter-defibrillator leads (24.6%), and 21 leads for which details were unknown; 46.6% of leads were passive fixation leads. The median lead dwell time was 74 months [interquartile range (IQR) 41-112]. Clinical success was obtained in 97.0% of procedures, and complete extraction was achieved for 96.5% of leads. Major complications occurred in 22/2205 procedures (1%), with a peri-operative or procedure-related mortality rate of 4/2205 (0.18%). Minor complications occurred in 3.1% of procedures. A total of 1552 leads (in 992 patients) with a median dwell time of 106 months (IQR 66-145) were extracted using the Evolution rotational TLE tool. In this subgroup, complete success was obtained for 95.2% of leads with a procedural mortality rate of 0.4%. CONCLUSION: Patient outcomes in the PROMET study compare favourably with other large TLE trials, underlining the capability of rotational TLE tools and techniques to match laser methods in efficacy and surpass them in safety.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
16.
Pacing Clin Electrophysiol ; 43(1): 68-77, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31808165

RESUMEN

BACKGROUND: The outcomes of pulmonary vein isolation (PVI) for persistent atrial fibrillation (AF) are suboptimal. The entire pulmonary venous component (PV-Comp), consisting of the pulmonary veins, their antra, and the area between the antra, provides triggers and substrate for AF. PV-Comp isolation is an alternative strategy for persistent AF ablation. METHODS: Among 328 patients with persistent AF who underwent a first radiofrequency ablation procedure, 200 patients (PVI, n = 100; PV-Comp isolation, n = 100) were selected by propensity score matching. Both groups were followed up for 1 year. RESULTS: At 6- and 12-month follow-up, atrial tachyarrhythmia (AF/atrial tachycardia) recurred in 41 and 61 patients in PVI group and 22 (P = .006) and 33 patients (P < .001) in PV-Comp isolation group, respectively. PV-Comp isolation was associated with longer mean time to recurrence (PVI: 8 months, PV-Comp isolation: 10 months, log-rank P < .001) and a lower probability of recurrence (odds ratio [OR] = 0.32; 95% confidence of interval [CI] = 0.18-0.56, P < .001), with no increase in procedural complications (PVI: 5 of 100, PV-Comp isolation: 6 of 100, P = .76). Procedure duration was longer in PV-Comp isolation group (PVI: 186 ± 42 min, PV-Comp isolation: 238 ± 44 min, P < .001), as well as fluoroscopy time (PVI: 22 ± 16 min, PV-Comp isolation: 31 ± 21 min, P = .001). CONCLUSION: PV-Comp isolation for persistent AF reduced atrial tachyarrhythmia recurrence up to 1 year compared with PVI alone. While procedure and fluoroscopy time increased, there was no difference in procedural complications.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Anciano , Egipto , Electrocardiografía , Mapeo Epicárdico , Femenino , Fluoroscopía , Humanos , Londres , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Recurrencia
17.
Pacing Clin Electrophysiol ; 43(12): 1515-1520, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32860243

RESUMEN

BACKGROUND: Small series has shown that cardiac resynchronisation therapy (CRT) can be achieved in a majority of patients using exclusively cephalic venous access. We sought to determine whether this method is suitable for widespread use. METHODS: A group of 19 operators including 11 trainees in three pacing centres attempted to use cephalic access alone for all CRT device implants over a period of 8 years. The access route for each lead, the procedure outcome, duration, and complications were collected prospectively. Data were also collected for 105 consecutive CRT device implants performed by experienced operators not using the exclusively cephalic method. RESULTS: A new implantation of a CRT device using exclusively cephalic venous access was attempted in 1091 patients (73.6% male, aged 73 ± 12 years). Implantation was achieved using cephalic venous access alone in 801 cases (73.4%) and using a combination of cephalic and other access in a further 180 (16.5%). Cephalic access was used for 2468 of 3132 leads implanted (78.8%). Compared to a non-cephalic reference group, complications occurred less frequently (69/1091 vs 12/105; P = .0468), and there were no pneumothoraces with cephalic implants. Procedure and fluoroscopy duration were shorter (procedure duration 118 ± 45 vs 144 ± 39 minutes, P < .0001; fluoroscopy duration 15.7 ± 12.9 vs 22.8 ± 12.2 minutes, P < .0001). CONCLUSIONS: CRT devices can be implanted using cephalic access alone in a substantial majority of cases. This approach is safe and efficient.


Asunto(s)
Vena Axilar , Dispositivos de Terapia de Resincronización Cardíaca , Cateterismo Periférico/métodos , Competencia Clínica , Anciano , Terapia de Resincronización Cardíaca/métodos , Femenino , Humanos , Masculino , Estudios Prospectivos
18.
J Cardiovasc Electrophysiol ; 30(3): 357-365, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30556609

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) using high power delivered by SmartTouch Surround Flow (STSF) catheters guided by ablation index (AI) was evaluated in a multicenter registry. METHODS: Patients with paroxysmal AF underwent PVI with STSF catheters using 30 W on the posterior wall and 40 W elsewhere. AI targets were 350 posterior walls and 450 elsewhere. Procedures were compared with controls using conventionally irrigated contact force-sensing catheters using conventional powers (25 W posterior wall and 30 W elsewhere) guided by force-time integral (no agreed targets). The waiting period of 30 minutes was observed before adenosine administration to assess acute pulmonary vein (PV) reconnection. RESULTS: One hundred patients from four centers were included: 50 patients in the high power ablation index (HPAI) group and 50 controls. Procedure time was 22% shorter in the HPAI group (156 [133.8-179] vs 199 [178.5-227] minutes; P < 0.001). Duration of the radiofrequency application was 37% shorter in the HPAI group (27.2 [21.5-35.8] vs 43.2 [35.1-52.1] minutes; P < 0.001). Acute PV reconnection was reduced (28 of 200 [14%] vs 48 of 200 [24%] veins; P = 0.015). Reconnection was predicted by a largest interlesion distance greater than 6 mm, a lesion with impedance drop less than 2.5 Ω, contact force less than 6 g, or less than 68% of the regional AI target (all P < 0.001). Freedom from atrial arrhythmia at 1 year off antiarrhythmic drugs after a single procedure was 78% in the HPAI group vs 64% in the control group ( P = 0.186). CONCLUSION: High-powered ablation guided by AI was safe and led to shorter procedure times with reduced acute PV reconnection compared with conventional ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Potenciales de Acción , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Estudios de Casos y Controles , Ablación por Catéter/efectos adversos , Inglaterra , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Tempo Operativo , Venas Pulmonares/fisiopatología , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
19.
Europace ; 21(12): 1890-1899, 2019 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-31665280

RESUMEN

AIMS: Female sex is considered an independent risk factor of transvenous leads extraction (TLE) procedure. The aim of the study was to evaluate the effectiveness of TLE in women compared with men. METHODS AND RESULTS: A post hoc analysis of risk factors and effectiveness of TLE in women and men included in the ESC-EHRA EORP ELECTRa registry was conducted. The rate of major complications was 1.96% in women vs. 0.71% in men; P = 0.0025. The number of leads was higher in men (mean 1.89 vs. 1.71; P < 0.0001) with higher number of abandoned leads in women (46.04% vs. 34.82%; P < 0.0001). Risk factors of TLE differed between the sexes, of which the major were: signs and symptoms of venous occlusion [odds ratio (OR) 3.730, confidence interval (CI) 1.401-9.934; P = 0.0084], cumulative leads dwell time (OR 1.044, CI 1.024-1.065; P < 0.001), number of generator replacements (OR 1.029, CI 1.005-1.054; P = 0.0184) in females and the number of leads (OR 6.053, CI 2.422-15.129; P = 0.0001), use of powered sheaths (OR 2.742, CI 1.404-5.355; P = 0.0031), and white blood cell count (OR 1.138, CI 1.069-1.212; P < 0.001) in males. Individual radiological and clinical success of TLE was 96.29% and 98.14% in women compared with 98.03% and 99.21% in men (P = 0.0046 and 0.0098). CONCLUSION: The efficacy of TLE was lower in females than males, with a higher rate of periprocedural major complications. The reasons for this difference are probably related to disparities in risk factors in women, including more pronounced leads adherence to the walls of the veins and myocardium. Lead management may be key to the effectiveness of TLE in females.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Remoción de Dispositivos , Complicaciones Intraoperatorias/epidemiología , Complicaciones Posoperatorias/epidemiología , Infecciones Relacionadas con Prótesis/terapia , Anciano , Anciano de 80 o más Años , Suministros de Energía Eléctrica , Europa (Continente) , Femenino , Humanos , Recuento de Leucocitos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Marcapaso Artificial , Sistema de Registros , Factores Sexuales , Factores de Tiempo , Insuficiencia de la Válvula Tricúspide/epidemiología , Trombosis de la Vena/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA