Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Mol Recognit ; 37(4): e3088, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38760976

RESUMEN

Despite the necessity of the study of therapeutic drug monitoring of clonazepam (CLZ), there are only a few fast detection methods available for determining CLZ in biological media. This study aims to develop a cost-effective and ratiometric probe for the quantification of CLZ in plasma samples. Fluorescent polydopamine nanoparticles were produced through a self-polymerization process at a pH of 8.5. Rhodamine B molecules were employed as a fluorescent reference material, emitting stable fluorescence in the visible range. The fabricated probe exhibited a specific detection capability for CLZ. The fluorescence emission of the probe was enhanced in two concentration ranges: from 50 ng/mL to 1.0 µg/mL and from 1.0 to 15.0 µg/mL with a lower limit of quantification of 50 ng/mL, indicating the sensitivity of the probe for detecting CLZ plasma levels. The accuracy of the probe is favorable which could be recommended for CLZ monitoring in the biological media. Furthermore, this probe is highly specific towards CLZ in the presence of various interfering agents which is mainly caused by its ratiometric nature. The developed platform showed high reliability in quantifying CLZ concentrations in patients' plasma samples. Hence, the fabricated probe could be recommended as a reliable method for the routine detection of CLZ in clinical settings.


Asunto(s)
Clonazepam , Colorantes Fluorescentes , Nanopartículas , Espectrometría de Fluorescencia , Clonazepam/sangre , Clonazepam/química , Humanos , Nanopartículas/química , Colorantes Fluorescentes/química , Espectrometría de Fluorescencia/métodos , Polímeros/química , Rodaminas/química , Indoles/química , Indoles/sangre , Límite de Detección , Monitoreo de Drogas/métodos
2.
Phys Chem Chem Phys ; 25(35): 23358-23369, 2023 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-37615695

RESUMEN

Chemiresistive gas sensors are metal oxide-based sensors that have received significant attention in different fields. Ambient gas sensors are especially important in the fabrication of wearable probes for the real-time detection of biomarkers in human body samples. Usually, room temperature sensors are affordable due to their low power consumption, resulting in simple instrumentation and maintenance. To fabricate versatile gas sensors, i.e. sensitive, selective, ambient temperature operating gas sensors, and improve the sensing performance of the traditionally used sensor, new materials play an important role. In other words, new advanced materials are essential for designing and fabricating new gas sensors. Hence, in this review, the application and impact of new advanced materials in the fabrication of reliable gas sensors are discussed in detail. Special emphasis is given to the effect of new materials in the fabrication of room-temperature operating systems. Finally, future research outlook and possible challenges that may be encountered by reliable gas sensors are also explained.

3.
J Sep Sci ; 46(14): e2201028, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37179451

RESUMEN

A graphene oxide-based aerogel was synthesized and applied to the extraction and the determinations with the high-performance liquid chromatography-ultraviolet detector. After the characterization of the produced graphene-aerogel, it was utilized as a dispersive solid-phase extraction sorbent for risperidone extraction from plasma samples. Aerogels are materials with a large surface area-to-mass ratio and plenty of core with functional groups which can easily attach to the analytes to extract them to the second phase. The suggested method determined risperidone in plasma samples in the wide dynamic range from 20 ng/ml to 3 µg/ml. The limits of detection and quantification of the developed method were calculated as 2.4 and 8.2 ng/ml, respectively. As a novel feature, the developed method has no need to precipitate plasma proteins, improving the analytical performance of the analysis. Also, for the first time, the produced materials were utilized for the extraction of risperidone from the plasma samples. The obtained results revealed that the developed approach could be employed as an accurate method for the quantification of risperidone in real plasma samples.


Asunto(s)
Grafito , Grafito/química , Risperidona , Extracción en Fase Sólida/métodos , Cromatografía Líquida de Alta Presión/métodos
4.
Mikrochim Acta ; 191(1): 30, 2023 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-38095752

RESUMEN

A simple and sensitive dual-emission ratiometric fluorescent probe was developed using zeolitic imidazolate framework 8 (ZIF8) and L-ascorbic acid Au-doped dopamine nanoparticles (ZIF8/L-ASC-AuNP/DA NP) for the determination of pioglitazone (Pio), an oral hypoglycemic agent and insulin sensitizer, in real samples. The prepared system was based on the Pio-enhanced dual-emission intensity of ZIF8/L-ASC-AuNP/DA NP. The potential impact of various parameters on the system's emission intensity was tested. According to the findings, there is a strong linear correlation between the system's turn-on fluorescence intensity and Pio concentrations in the range 0.3 nM to 30.0 µM. The obtained value for the limit of detection (LOD) was 0.14 nM. In addition, the intra- and inter-day accuracy of the nanoprobe was studied and the findings revealed satisfactory precision and accuracy of the system. The short-term and freeze-thaw stability of Pio in plasma samples was evaluated and the results indicated the high stability of the developed nanoprobe under the test conditions. Pio was accurately detected in human plasma samples under ideal conditions with analytical recoveries in the range 86.0 - 109.3%. The results showed that the devised probe may be employed as an easy, sensitive, and precise approach for detecting Pio in real samples.


Asunto(s)
Nanopartículas , Zeolitas , Humanos , Pioglitazona , Colorantes Fluorescentes , Fluorescencia
5.
Mikrochim Acta ; 190(7): 266, 2023 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-37338626

RESUMEN

A novel ratiometric fluorescent sensor was fabricated for the fast and facile determination of cyclosporine A (CsA). Due to the narrow therapeutic index of CsA, its desired therapeutic effects are evident within a limited range of blood concentration, indicating the fundamental role of therapeutic drug monitoring in CsA pharmacological response. In this study, a two-photon fluorescence probe based on the zeolitic imidazolate framework (ZIF-8) and norepinephrine-capped silver nanoparticles (AgNPs@NE) was employed for the quantification of the CsA in human plasma samples. In the presence of CsA, the fluorescent emission intensity of ZIF-8-AgNPs@NE was quenched. Under the optimum conditions, the proposed probe determines CsA in plasma samples in two linear ranges of 0.01 to 0.5 µg mL-1 and 0.5 to 10 µg mL-1. The developed probe demonstrates the advantages of a facile and fast platform with limit of detection as low as 0.007 µg mL-1. At last, this method was applied to find CsA concentration in four patients receiving oral CsA regimen which indicates it as a promising method for on-site detection applications.


Asunto(s)
Nanopartículas del Metal , Puntos Cuánticos , Zeolitas , Humanos , Colorantes Fluorescentes , Ciclosporina , Plata
6.
Trends Analyt Chem ; 143: 116342, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34602681

RESUMEN

There have been many efforts to synthesize advanced materials that are capable of real-time specific recognition of a molecular target, and allow the quantification of a variety of biomolecules. Scaffold materials have a porous structure, with a high surface area and their intrinsic nanocavities can accommodate cells and macromolecules. The three-dimensional structure (3D) of scaffolds serves not only as a fibrous structure for cell adhesion and growth in tissue engineering, but can also provide the controlled release of drugs and other molecules for biomedical applications. There has been a limited number of reports on the use of scaffold materials in biomedical sensing applications. This review highlights the potential of scaffold materials in the improvement of sensing platforms and summarizes the progress in the application of novel scaffold-based materials as sensor, and discusses their advantages and limitations. Furthermore, the influence of the scaffold materials on the monitoring of infectious diseases such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and bacterial infections, was reviewed.

7.
J Mol Recognit ; 33(11): e2871, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32677119

RESUMEN

A novel folic acid functionalized terbium-doped dendritic fibrous nanoparticle (Tb@KCC-1-NH2 -FA) with high surface area was synthesized using a novel hydrothermal protocol. In the present work, we report the fluorescent Tb-doted nanomaterial with emission wavelength at 497 nm which confirms the formation of Tb@KCC-1-NH2 -FA. Synthesized nanoparticles were investigated through transmission electron microscope, field emission scanning electron Microscopy, Fourier transform infrared spectra, Brunauer-Emmett-Teller, energy dispersive X-ray, Zeta potential and particle size distribution values and AFM (Atomic force microscopy) techniques. Specially, our desired nanomaterial which has FA moieties on the surface of Tb@KCC-1-NH2-FA where interact with folate receptor (FR) which there is on the surface of the various cancer cells. For this purpose, fluorescence microscopy images were used to prove the uptake of FA based nanomaterial with FR-positive MDA breast cancer and HT 29 colon cancer cells. Also HEK 293 normal cells as FR-negative cells verified the specificity of our desired nanomaterial toward the FR-positive cells. The cytotoxicity survey of Tb@KCC-1-NH2 -FA was examined by MTT assays against MDA breast cancer, HT 29 colon cancer and HEK 293 Normal cell lines which confirmed their biocompatible nature with any significant cytotoxic effects even for concentration higher than 900 µg/mL which could be used as a non-toxic catalyst or carrier in biological ambient. Hence, Tb@KCC-1-NH2 -FA were synthesized using green and hydrothermal method; the process was simple with good productivity and desired nanocomposite was non-toxic.


Asunto(s)
Técnicas Biosensibles , Ácido Fólico/farmacología , Nanopartículas/química , Terbio/farmacología , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Neoplasias de la Mama/tratamiento farmacológico , Proliferación Celular/efectos de los fármacos , Neoplasias del Colon/tratamiento farmacológico , Femenino , Receptor 1 de Folato/genética , Ácido Fólico/química , Células HEK293 , Células HT29 , Humanos , Microscopía Fluorescente , Dióxido de Silicio/química , Dióxido de Silicio/farmacología , Terbio/química
8.
Heliyon ; 10(18): e37914, 2024 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-39323834

RESUMEN

In this work, an innovative ratiometric sensing platform was developed for the determination of methotrexate (MTX), an antifolate drug, a chemotherapy agent, and an immune system suppressant based on blue emission graphene quantum dots/Rhodamine B doped gold nanostars (B-GQDs/Au NSt-RB). The developed sensor was a dual-emission fluorescent probe with two major emission peaks at 440 nm (B-GQDs) and 580 nm (Au NSt-RB) by exciting at 330 nm. Based on the inhibiting effect of MTX on the system's fluorescence density, the stable ratiometric fluorescent probe was used for the rapid determination of MTX in aquatic solutions and spiked human serum samples. The results indicated good linear correlations over the logarithmic concentration range of 0.3 nM-50.0 µM. In addition, B-GQDs/Au NSt-RB can further realize highly sensitive detection of MTX with a low LOD value of 2.28 × 10-10 M. The RSD% values obtained for the intra-day and inter-day precision were 0.63-3.86 %. With recoveries of 98.2-100.1 % and 98.7-100.5 %, respectively. The short-term temperature and freeze-thaw tests confirmed the higher stability of the developed sensor. In addition, the calculated recoveries for MTX recognition in real samples were in the range of 98-102 %. These findings suggested the excellent potential of the ratiometric fluorescence B-GQDs/Au NSt-RB sensor for detecting MTX in real plasma samples.

9.
BMC Chem ; 18(1): 176, 2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39294675

RESUMEN

In this study, a novel fluorescence nanoprobe based on Materials of Institute Lavoisier (MIL-101) metal-organic frameworks embedding into the agarose hydrogel is fabricated using a hydrothermal technique. It uses for sensitive quantification of deferiprone in exhaled breath condensate (EBC) samples. The morphology and characterization of MIL-101/agarose nanocomposite hydrogel is studied by transmission electron microscopy, dynamic light scattering instrument, powder X-ray diffraction analysis, and Fourier transform infrared spectroscopy. The probe shows a reasonable fluorescence intensity quenching in the presence of deferiprone due to the interactions between iron centers in MIL-101 (Fe) and deferiprone, which likely form non-fluorescent complexes. The proposed nanoprobe demonstrates a linear calibration curve from 0.005 to 1.5 µg mL- 1 with a detection limit of 0.003 µg mL- 1. The intra- and inter-day precision of the reported method are 0.3% and 0.4% (n = 5, deferiprone concentration = 1.0 µg mL- 1), respectively. This method demonstrates high sensitivity and specificity towards deferiprone in the EBC samples and also presents a sensing platform with simplicity, convenience, fast implementation, and cost-effective in medical monitoring.

10.
RSC Adv ; 14(35): 25329-25336, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39139239

RESUMEN

Currently, the growth and development of cancer are rising in the world, and as a result, the use of anticancer drugs such as cisplatin has also increased. Considering that the therapeutic index of anticancer drugs is low, it is essential to design and develop an accurate and correct method to analyze and determine the concentration of anticancer drugs in the biological samples. In this study, graphene quantum dots/hydrogel nanocomposite was used to determine cisplatin concentration in urine samples. A three-dimensional network of polyvinyl alcohol hydrogel was composited with graphene quantum dots and used as a probe for the determination of cisplatin. The morphology and characterization of the probe were studied using high-resolution transmission electron microscopy, dynamic light scattering, energy-dispersive X-ray spectroscopy, and Fourier transform infrared spectroscopy. This platform showed a linear calibration curve in the range from 4.3 to 25.0 ng mL-1 with a detection limit of 1.2 ng mL-1. The relative intra- and inter-day standard deviations of the probe for the determination of cisplatin were 1.8% and 3.6% (n = 5), respectively. The validated method was used for determination of cisplatin in urine samples of patients receiving this medication with acceptable results and good recoveries.

11.
Heliyon ; 10(17): e37253, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-39286091

RESUMEN

Vancomycin is employed to treat infections caused by gram-positive bacteria. Ensuring precise vancomycin dosages is essential to avoid the emergence of bacterial resistance. In the current study, a fluorescent nanoprobe was designed for vancomycin determination in exhaled breath condensate samples. The nanoprobe was based on carbon dots (CDs) doped with nitrogen, sulfur, phosphorus, and chlorine (NSPCl-doped CDs). Vancomycin significantly reduced the fluorescence of NSPCl-doped CDs and presented a quenching process in the analytical response of the probe within a concentration range of 0.01-2.0 µg mL-1 due to forming a non-fluorescent complex. The nanoprobe's intra-day and inter-day relative standard deviations were 1.4 % and 3.2 %, respectively. This nanoprobe was successfully used to determine vancomycin in the patients receiving this drug collected from the expiratory circuit of the mechanical ventilator.

12.
Spectrochim Acta A Mol Biomol Spectrosc ; 297: 122714, 2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-37080048

RESUMEN

In the present work, sulfide-doped carbon dots (S-CDs)/cadmium sulfide quantum dots (CdS QDs) ratiometric fluorescent nanosensor has been developed for sensitive and selective determination of glibenclamide (GLC) in biological fluids. The method was based on the quenching effect of GLC on the dual-emission intensity of the S-CDs/CdS QDs system at 420 nm and 650 nm, which are related to S-CDs and CdS QDs, respectively. The fluorimetric data analysis indicated that the fluorescence signals of the system were quenched by adding GLC in a concentration-dependent manner. A good linear relationship was observed between GLC concentration and the quenched fluorescence intensity of the S-CDs/CdS QDs in the range of 0.3 nM-10.0 µM. The limit of detection (LOD) value was estimated to be 0.12 nM. Furthermore, under optimum conditions, GLC was detected in spiked human serum sample (as real media) using the developed ratiometric nanosensor with an accuracy of 99.6%. According to the results, the developed dual-emission system can be used as a reliable method for the quantitative detection of GLC in biological samples.


Asunto(s)
Técnicas Biosensibles , Puntos Cuánticos , Humanos , Gliburida , Carbono , Sulfuros , Colorantes Fluorescentes
13.
Crit Rev Anal Chem ; 53(5): 1116-1131, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-34894901

RESUMEN

Diabetes mellitus (DM) is a global health problem leading to many complications and disabilities in life adjusting activities and even dead. Monitoring glucose levels is a key factor in diagnosis and management of DM. Conventional glucose sensors consisted of immobilized enzymes, are so susceptible to environmental conditions. In this way, nonenzymatic biosensors have attracted extensive attentions in many clinical diagnostics applications. To date, the finger pricking test is a common enzyme-based glucometer that is an invasive and inconvenient and may lead to infections in the injection sites. So, working on the possibility of cutaneous or subcutaneous insertion of devices as a noninvasive or minimally-invasive systems for continuous glucose controlling approaches through human biofluids (blood, perspiration, tears, saliva, etc.) have stimulated growing interest. This review summarizes recent nonenzymatic and noninvasive biofluids glucose monitoring systems which are highly resilience and stretchable to continuously adapt to body movements during common physical activity. Sensors are based on their constituent materials including carbon-based, metal nanoparticles, polymer, and hydrogel systems are classified for electrochemical, and optical glucose detection. Finally, we address the drawbacks and challenges of enzyme-free sensors which are aroused sustaining research passion to be used in point-of-care medical diagnostics applications.


Asunto(s)
Técnicas Biosensibles , Diabetes Mellitus , Dispositivos Electrónicos Vestibles , Humanos , Glucemia , Automonitorización de la Glucosa Sanguínea , Técnicas Electroquímicas , Glucosa
14.
Talanta ; 265: 124846, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37379752

RESUMEN

Doxorubicin (DOX) is a highly effective anticancer drug with a narrow therapeutic window; thus, sensitive and timely detection of DOX is crucial. Using electrodeposition of silver nanoparticles (AgNPs) and electropolymerization of alginate (Alg) layers on the surface of a glassy carbon electrode, a novel electrochemical probe was constructed (GCE). The fabricated AgNPs/poly-Alg-modified GCE probe was utilized for the quantification of DOX in unprocessed human plasma samples. For the electrodeposition of AgNPs and electropolymerization of alginate (Alg) layers on the surface of GCE, cyclic voltammetry (CV) was used in the potential ranges of -2.0 to 2.0 V and -0.6 to 0.2 V, respectively. The electrochemical activity of DOX exhibited two oxidation processes at the optimum pH value of 5.5 on the surface of the modified GCE. The DPV spectra of poly(Alg)/AgNPs modified GCE probe toward consecutive concentrations of DOX in plasma samples demonstrated wide dynamic ranges of 15 ng/mL-0.1 µg/mL and 0.1-5.0 µg/mL, with a low limit of quantification (LLOQ) of 15 ng/mL. The validation results indicated that the fabricated electrochemical probe might serve as a highly sensitive and selective assay for the quantification of DOX in patient samples. As an outstanding feature, the developed probe could detect DOX in unprocessed plasma samples and cell lysates without the requirement for pretreatment.


Asunto(s)
Incrustaciones Biológicas , Nanopartículas del Metal , Humanos , Carbono , Doxorrubicina/análisis , Plata , Incrustaciones Biológicas/prevención & control , Electrodos , Alginatos , Técnicas Electroquímicas/métodos , Límite de Detección
15.
Heliyon ; 9(8): e18404, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37576308

RESUMEN

Tacrolimus (Tac) is a well-documented immunosuppressive agent for the prevention of graft-vs-host diseases in several types of organ transplants. The narrow therapeutic window and the individual-variable pharmacokinetics of Tac demonstrate the importance of regular therapeutic drug monitoring (TDM) as an imperative concept for its oral medication regimens. A simple, one-step, selective, and sensitive colorimetric platform is fabricated for the determination of Tac by surface modification of the silver nanoparticles (AgNPs) via norepinephrine (NE) molecules. The attachment of NE and Tac induces the aggregation of the AgNPs, which is observed by color distinction (yellow to brown) and a noteworthy shifting of the absorption peak in the visible region. The fabricated nanoprobe can detect Tac concentrations in plasma samples in two linear ranges from 2 ng/mL to 70 ng/mL and 70 ng/mL to 1000 ng/mL with R2 > 0.99. The limit of detection (LOD) was calculated as low as 0.1 ng/mL. The developed method was applied for the determination of Tac in patient's plasma samples under Tac medication therapy.

16.
Bioimpacts ; 13(6): 467-474, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38022377

RESUMEN

Introduction: Nisin is a bacteriocin produced by Streptococcus and Lactococcus species and has antimicrobial activity against other bacteria. Nisin omits the need to use chemical preservatives in food due to its biological preserving properties. Methods: In the present in vitro study, we investigated nisin interaction with bovine serum albumin (BSA) using fluorescence spectroscopy and surface plasmon resonance (SPR) analysis to obtain information about the mechanisms of BSA complex formation with nisin. Results: The BSA fluorescence intensity values gradually diminished with rising nisin concentration. The BSA fluorescence quenching analysis indicated that a combined quenching mechanism plays the main role. Finally, the Kb values were reduced with increasing temperature, which is demonstrative of nisin-BSA complex stability decrease at high temperatures. The negative values of ΔH° and ΔS° showed that hydrogen bonds and van der Waals forces are the foremost binding force between BSA and nisin. Meanwhile, the negative values of ΔG° demonstrated the exothermic and random nature of the reaction process. The results of the SPR verified the gained results through the fluorescence spectroscopy investigation, which denoted that the BSA affinity to nisin diminished upon increasing temperature. Conclusion: Overall, fluorescence spectroscopy and SPR results showed that the BSA interaction with nisin decreased with rising temperatures.

17.
RSC Adv ; 13(31): 21432-21440, 2023 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-37465572

RESUMEN

A novel electrochemical probe was established for the quantification of apixaban (APX) in unprocessed plasma samples. Efficiently oxidized graphene oxide aerogels (EEGO-AGs) and nano-sized Bi2Fe4O9 (BFO) particles were electrodeposited on the surface of a glassy carbon electrode (GCE). In this work, a ratiometric electrochemical method was introduced for APX detection to enhance the specificity of the probe in plasma samples. The fabricated ratiometric probe was employed for the indirect detection determination of APX using K3[Fe(CN)6]/K4[Fe(CN)6] as the redox pair. The differential pulse voltammetry technique was used to record the current alteration of the BFO/EEGO-AG-functionalized GCE probe at various APX concentrations. The probe response was proportional to the APX concentrations from 10 ng mL-1 to 10 µg mL-1 with a low limit of quantification (LLOQ) of 10 ng mL-1. After validation, this method was successfully utilized for the determination of APX in patients' plasma samples who have taken APX regularly. The fabricated chemosensor detected APX concentrations in unprocessed plasma samples with high selectivity, resulting from the physical filtering antifouling activity of aerogels.

18.
Iran J Kidney Dis ; 17(3): 126-134, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37337796

RESUMEN

INTRODUCTION: Indoxyl sulfate (IS) and para-cresol (p-cresol) are uremic toxins with high protein bonding index that accumulate in the body with decreasing kidney function. The main purpose of the current investigation was to compare the concentration of p-cresol and IS in serum of the type II diabetic individuals with and without nephropathy. METHODS: Fifty-five patients with type II diabetes mellitus were divided into two groups: case and control. The case group consisted of 26 diabetic patients with nephropathy (proteinuria and serum creatinine below 1.5 mg/dL) without any other kidney diseases. The control group included 29 patients without diabetic nephropathy. Patients with advanced heart disease, cerebrovascular accident and other inflammatory or infectious diseases were excluded. Five mL of venous blood was taken from each patient in the morning fasting state. Then other laboratory tests including serum uric acid and creatinine levels, serum urea nitrogen, lipids and glucose were measured by standard methods. P-Cresol and IS levels were measured by the spectrofluorimetric method after extraction. We also filled out a checklist with information regarding the duration of their disease, medication history (oral or injectable), and other demographic information. There were no significant differences between the two groups regarding the investigated factors Results. There were no significant difference among the investigated factors between the two groups (P > .05) except for the serum creatinine, proteinuria and estimated glomerular filtration rate, where the mean values of cases were considerably higher than those of the controls. Serum IS and p-cresol levels were also significantly higher in the case group (P < .05). CONCLUSION: According to the findings, it seems that IS, and p-cresol may play a role in the development of diabetic nephropathy and other complications of diabetes mellitus.  DOI: 10.52547/ijkd.7266.


Asunto(s)
Diabetes Mellitus Tipo 2 , Nefropatías Diabéticas , Humanos , Nefropatías Diabéticas/diagnóstico , Nefropatías Diabéticas/etiología , Indicán/uso terapéutico , Diabetes Mellitus Tipo 2/complicaciones , Creatinina , Ácido Úrico , Proteinuria
19.
Heliyon ; 9(2): e13207, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36747548

RESUMEN

Early-stage detection is a vital factor in the later treatment and prognosis of cancer. Enhancing the sensitivity and specificity of the cancer detection pathological and experimental approaches can affect the morbidity and mortality of this disease. A folic acid (FA)-functionalized silica quantum dots (SiQDs)/KCC-NH2@SiO2 nanomaterials were synthesized and characterized as a bioimaging agent of the MCF 7 cancer cells. These nanoparticles showed biocompatible nature with specificity towards folate receptor (FR)-overexpressed MCF 7 cancer cells. Viability findings suggested that the SiQDs/KCC-NH2@SiO2/FA nanomaterials have nontoxic nature towards the cells in the concentration of 200 µg/mL. Fluorescence microscopy images were utilized to estimate the cell internalization of the nanoparticles and further verified by the flow cytometry technique. The differentiation ability of the nanoparticles was also approved by incubation with FR-negative HEK 293 normal cells. The SiQDs/KCC-NH2@SiO2/FA nanoparticle exhibited high stability, bright and high quantum yield fluorescence emission, proposing as a high-quality material for in vivo bioimaging of FR-overexpressed circulating tumoral cancer cells (CTCs).

20.
Luminescence ; 27(4): 268-73, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-21853518

RESUMEN

Optimized conditions, validation and practical applications of a new, rapid and specific fluorometric method for the determination of deferiprone (DFP) in urine and serum samples are reported. The proposed method, which is based on the formation of a luminescent complex with Tb(3+) ion, is evaluated in terms of linearity, accuracy, precision, stability, recovery and limits of detection (LOD) and quantification (LOQ). Under optimum conditions (pH 7.5, [Tb(3+)] = 3 × 10(-4) mol/L, temperature 0 °C and excitation wavelength 295 nm), the relative intensities at 545 nm are linear, with the concentration of DFP in the range 0.072-13 mmol/L for urine and serum samples. The LOD and LOQ, respectively, are calculated to be 0.014 and 0.045 mmol/L for urine and 0.022 and 0.072 mmol/L for serum samples. The intra-day and inter-day values for the precision and accuracy of the proposed method are all < 5%, and the recovery of the method is in the range 97.1-103.8%. The method was applied to human urine and serum samples collected from patients receiving DFP. The results indicated that the method can be successfully applied to the determination of DFP in human urine and serum samples collected for clinical or biopharmaceutical investigations in which simple, rapid, cheap and specific determination methods facilitate and speed up the analytical procedure.


Asunto(s)
Fluorometría/métodos , Mediciones Luminiscentes/métodos , Piridonas/sangre , Piridonas/orina , Terbio/química , Deferiprona , Humanos , Límite de Detección
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA