Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Breast Cancer Res Treat ; 189(2): 387-398, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34216316

RESUMEN

PURPOSE: To evaluate and compare health-related quality of life (HRQL) of women with early-stage breast cancer (BC) treated with different radiotherapy (RT) regimens. METHODS: Data were collected from five prospective cohorts of BC patients treated with breast-conserving surgery and different RT regimens: intraoperative RT (IORT, 1 × 23.3 Gy; n = 267), external beam accelerated partial breast irradiation (EB-APBI, 10 × 3.85 Gy; n = 206), hypofractionated whole breast irradiation(hypo-WBI, 16 × 2.67 Gy; n = 375), hypo-WBI + boost(hypo-WBI-B, 21-26 × 2.67 Gy; n = 189), and simultaneous WBI + boost(WBI-B, 28 × 2.3 Gy; n = 475). Women ≥ 60 years with invasive/in situ carcinoma ≤ 30 mm, cN0 and pN0-1a were included. Validated EORTC QLQ-C30/BR23 questionnaires were used to asses HRQL. Multivariable linear regression models adjusted for confounding (age, comorbidity, pT, locoregional treatment, systemic therapy) were used to compare the impact of the RT regimens on HRQL at 12 and 24 months. Differences in HRQL over time (3-24 months) were evaluated using linear mixed models. RESULTS: There were no significant differences in HRQL at 12 months between groups except for breast symptoms which were better after IORT and EB-APBI compared to hypo-WBI at 12 months (p < 0.001). Over time, breast symptoms, fatigue, global health status and role functioning were significantly better after IORT and EB-APBI than hypo-WBI. At 24 months, HRQL was comparable in all groups. CONCLUSION: In women with early-stage breast cancer, the radiotherapy regimen did not substantially influence long-term HRQL with the exception of breast symptoms. Breast symptoms are more common after WBI than after IORT or EB-APBI and improve slowly until no significant difference remains at 2 years posttreatment.


Asunto(s)
Neoplasias de la Mama , Mama , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Preescolar , Femenino , Humanos , Lactante , Mastectomía Segmentaria , Estudios Prospectivos , Calidad de Vida
2.
Strahlenther Onkol ; 192(10): 705-13, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27538776

RESUMEN

BACKGROUND: Scarce data are available about the cosmetic result of single dose intraoperative electron radiotherapy (IOERT) in breast-conserving radiotherapy. METHODS AND MATERIALS: We included 71 breast cancer patients. Breast-conserving surgery and sentinel node procedure had started almost 3 years earlier. Subsequently, 26 patients were treated with IOERT and 45 patients received postoperative whole breast irradiation (WBI). For both groups we determined seven dimensionless asymmetry features. We compared the subjectively and the objectively derived cosmetic scores with each other. RESULTS: For four asymmetry features we noted significantly smaller differences for patients treated with IOERT when compared to those treated with WBI: relative breast contour difference, relative breast area difference and relative breast overlap difference. After correcting for excision volume a significant difference was noticed also for relative lower breast contour. For the IOERT group the cosmetic scores "excellent or good" as determined by each patient and one physician were 88 and 96 %, respectively. When the overall cosmetic scores for patients treated with IOERT and WBI were compared to those of the objectively derived scores, there was a fair level of agreement. CONCLUSION: For patients treated with IOERT we noted less asymmetry and high rates of "good or excellent" subjectively derived cosmetic scores. The level of agreement between the subjectively and the objectively derived cosmetic scores was limited. Due to the small sample size and the design of the study no definitive conclusions can be drawn.


Asunto(s)
Neoplasias de la Mama/patología , Neoplasias de la Mama/terapia , Técnicas Cosméticas , Fraccionamiento de la Dosis de Radiación , Electrones/uso terapéutico , Mastectomía Segmentaria/métodos , Anciano , Femenino , Humanos , Cuidados Intraoperatorios/métodos , Mastectomía/métodos , Persona de Mediana Edad , Tratamientos Conservadores del Órgano/métodos , Dosificación Radioterapéutica , Radioterapia Adyuvante/métodos , Resultado del Tratamiento
3.
Radiother Oncol ; 192: 110105, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38244780

RESUMEN

BACKGROUND AND PURPOSE: Previous research among Dutch radiotherapy centres (RTCs) showed that 69% of innovations was simultaneously implemented in 7/19 centres, with a success rate of 51%. However, no structure to share lessons learned about the implementation process existed. Therefore, a national Taskforce Implementation (TTI) was raised to stimulate efficient implementation of innovations. The aim of the current study was to develop and pilot-evaluate a website for facilitating mutual learning on implementation issues. MATERIAL AND METHODS: First, we made an inventory in all Dutch RTCs on their 10 most valuable innovations between 2019 and 2022. In-depth interviews, structured according to the Consolidated Framework for Implementation Research, were performed on the four most mentioned topics. A website was built, and pilot evaluated 1 year after the launch, using a qualitative survey amongst the TTI members. RESULTS: In 13/18 centres, 19 interviews were conducted on 1) automation, 2) patient participation, 3) adaptive radiotherapy 4) surface guided radiotherapy and tracking. Most innovations (13/16) were implemented with a delay, with many comparable challenges: e.g. shortage of personnel (7/16) and prioritization of projects (9/16). The website allows users to upload and search for projects, including implementation experiences. After 1 year, 14 projects were uploaded. The qualitative evaluation was largely positive with room for improvement, i.e.75 % would recommend the website to others. CONCLUSION: This study showed that RTCs experience comparable challenges when implementing innovations, thereby underlining the need for a platform to share implementation-lessons learned. The first concept of this platform was evaluated positively.

4.
Int J Radiat Oncol Biol Phys ; 113(3): 570-581, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35301990

RESUMEN

PURPOSE: To evaluate the ipsilateral breast tumor recurrence (IBTR) after 2 accelerated partial breast irradiation (APBI) techniques (intraoperative electron radiation therapy [IOERT] and external beam APBI [EB-APBI]) in patients with early-stage breast cancer. METHODS AND MATERIALS: Between 2011 and 2016, women ≥60 years of age with breast carcinoma or Ductal Carcinoma In Situ (DCIS) of ≤30 mm and cN0 undergoing breast-conserving therapy were included in a 2-armed prospective multicenter cohort study. IOERT (1 × 23.3 Gy prescribed at the 100% isodose line) was applied in 1 hospital and EB-APBI (10 × 3.85 Gy daily) in 2 other hospitals. The primary endpoint was IBTR (all recurrences in the ipsilateral breast irrespective of localization) at 5 years after lumpectomy. A competing risk model was used to estimate the cumulative incidences of IBTR, which were compared using Fine and Gray's test. Secondary endpoints were locoregional recurrence rate, distant recurrence, disease-specific survival and overall survival. Univariate Cox regression models were estimated to identify risk factors for IBTR. Analyses were performed of the intention to treat (ITT) population (IOERT n = 305; EB-APBI n = 295), and sensitivity analyses were done of the per-protocol population (IOERT n = 270; EB-APBI n = 207). RESULTS: The median follow-up was 5.2 years (IOERT) and 5 years (EB-APBI). Cumulative incidence of IBTR in the ITT population at 5 years after lumpectomy was 10.6% (95% confidence interval, 7.0%-14.2%) after IOERT and 3.7% (95% confidence interval, 1.2%-5.9%) after EB-APBI (P = .002). The locoregional recurrence rate was significantly higher after IOERT than EB-APBI (12.1% vs 4.5%, P = .001). There were no differences between groups in other endpoints. Sensitivity analysis showed similar results. For both groups, no significant risk factors for IBTR were identified in the ITT population. In the per-protocol population, surgical margin status of the DCIS was the only significant risk factor for developing IBTR in both treatment groups. CONCLUSIONS: Ipsilateral breast tumor recurrences and locoregional recurrence rates were unexpectedly high in patients treated with IOERT, and acceptable in patients treated with EB-APBI.


Asunto(s)
Braquiterapia , Neoplasias de la Mama , Carcinoma Intraductal no Infiltrante , Braquiterapia/métodos , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Carcinoma Intraductal no Infiltrante/radioterapia , Carcinoma Intraductal no Infiltrante/cirugía , Estudios de Cohortes , Electrones , Femenino , Humanos , Mastectomía Segmentaria/métodos , Recurrencia Local de Neoplasia , Estudios Prospectivos
5.
Transplantation ; 78(10): 1523-31, 2004 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-15599318

RESUMEN

BACKGROUND: After heart transplantation, the donor heart is extrinsically denervated. No input of sympathetic or vagal nerves can influence the heart rate, resulting in a flat power spectrum of the beat-to-beat variability. The occurrence and the significance of reinnervation remain controversial. METHODS AND RESULTS: We monitored the evolution of heart rate variability (HRV) after heart transplantation, starting from a few weeks postoperatively up to 10 years after surgery. Twenty-four-hour Holter recordings of 216 heart-transplant patients were analyzed using time and frequency domain analysis of HRV. Analysis of all data revealed an increase in 24-hour and night-time total power starting from 2 years after transplantation. Low-frequency oscillations calculated over the total 24 hours, day- and nighttime increased significantly starting from year 4 and onward (year 4-8: P < 0.005). No evolution was found in high-frequency power. Subgroup analysis revealed a group with a clear spectral component (n = 16), a group with a small component (n = 124), and a group with a flat spectrum (n = 76). Only the first group revealed an evolution in both high- and low-frequency power. CONCLUSION: These results indicate three different types of evolution in HRV, with reinnervating patterns present in only a minority of the patients. The vast majority of the patients show no signs of reinnervation.


Asunto(s)
Frecuencia Cardíaca/fisiología , Trasplante de Corazón/fisiología , Presión Sanguínea/fisiología , Ritmo Circadiano , Electrocardiografía Ambulatoria/métodos , Estudios de Seguimiento , Sistema de Conducción Cardíaco/fisiología , Humanos , Estudios Retrospectivos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA