Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Int J Mol Sci ; 24(15)2023 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-37569531

RESUMEN

Radiotherapy is a cornerstone of cancer treatment, but tumor hypoxia and resistance to radiation remain significant challenges. Vascular normalization has emerged as a strategy to improve oxygenation and enhance therapeutic outcomes. In this study, we examine the radiosensitization potential of vascular normalization using metformin, a widely used anti-diabetic drug, and oxygen microbubbles (OMBs). We investigated the synergistic action of metformin and OMBs and the impact of this therapeutic combination on the vasculature, oxygenation, invasiveness, and radiosensitivity of murine 4T1 breast cancer. We employed in vivo Doppler ultrasonographic imaging for vasculature analysis, electron paramagnetic resonance oximetry, and immunohistochemical assessment of microvessels, perfusion, and invasiveness markers. Our findings demonstrate that both two-week metformin therapy and oxygen microbubble treatment normalize abnormal cancer vasculature. The combination of metformin and OMB yielded more pronounced and sustained effects than either treatment alone. The investigated therapy protocols led to nearly twice the radiosensitivity of 4T1 tumors; however, no significant differences in radiosensitivity were observed between the various treatment groups. Despite these improvements, resistance to treatment inevitably emerged, leading to the recurrence of hypoxia and an increased incidence of metastasis.


Asunto(s)
Neoplasias de la Mama , Metformina , Ratones , Humanos , Animales , Femenino , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/radioterapia , Microburbujas , Oxígeno , Metformina/farmacología , Metformina/uso terapéutico , Hipoxia Tumoral
2.
Exp Astron (Dordr) ; 56(2-3): 355-370, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38145002

RESUMEN

POLAR-2, a plastic scintillator based Compton polarimeter, is currently under development and planned for a launch to the China Space Station in 2025. It is intended to shed a new light on our understanding of Gamma-Ray Bursts by performing high precision polarization measurements of their prompt emission. The instrument will be orbiting at an average altitude of 383 km with an inclination of 42° and will be subject to background radiation from cosmic rays and solar events. In this work, we tested the performance of plastic scintillation bars, EJ-200 and EJ-248M from Eljen Technology, under space-like conditions, that were chosen as possible candidates for POLAR-2. Both scintillator types were irradiated with 58 MeV protons at several doses from 1.89 Gy(corresponding to about 13 years in space for POLAR-2) up to 18.7 Gy, that goes far beyond the expected POLAR-2 life time. Their respective properties, expressed in terms of light yield, emission and absorption spectra, and activation analysis due to proton irradiation are discussed. Scintillators activation analyses showed a dominant contribution of ß + decay with a typical for this process gamma-ray energy line of 511 keV.

3.
Exp Astron (Dordr) ; 55(2): 343-371, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37063519

RESUMEN

POLAR-2 is a space-borne polarimeter, built to investigate the polarization of Gamma-Ray Bursts and help elucidate their mechanisms. The instrument is targeted for launch in 2024 or 2025 aboard the China Space Station and is being developed by a collaboration between institutes from Switzerland, Germany, Poland and China. The instrument will orbit at altitudes between 340km and 450km with an inclination of 42 ∘ and will be subjected to background radiation from cosmic rays and solar events. It is therefore pertinent to better understand the performance of sensitive devices under space-like conditions. In this paper we focus on the radiation damage of the silicon photomultiplier arrays S13361-6075NE-04 and S14161-6050HS-04 from Hamamatsu. The S13361 are irradiated with 58MeV protons at several doses up to 4.96Gy, whereas the newer series S14161 are irradiated at doses of 0.254Gy and 2.31Gy. Their respective performance degradation due to radiation damage are discussed. The equivalent exposure time in space for silicon photomultipliers inside POLAR-2 with a dose of 4.96Gy is 62.9years (or 1.78years when disregarding the shielding from the instrument). Primary characteristics of the I-V curves are an increase in the dark current and dark counts, mostly through cross-talk events. Annealing processes at 25 ∘ C were observed but not studied in further detail. Biasing channels while being irradiated have not resulted in any significant impact. Activation analyses showed a dominant contribution of ß + particles around 511 keV. These resulted primarily from copper and carbon, mostly with decay times shorter than the orbital period.

4.
Sensors (Basel) ; 21(18)2021 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-34577220

RESUMEN

A direct verification of the three-dimensional (3D) proton clinical treatment plan prepared for tumor in the eyeball, using the Eclipse Ocular Proton Planning system (by Varian Medical Systems), has been presented. To achieve this, a prototype of the innovative two-dimensional (2D) circular silicone foils, made of a polymer with the embedded optically stimulated luminescence (OSL) material in powder form (LiMgPO4), and a self-developed optical imaging system, consisting of an illuminating light source and a high-sensitive CCD camera has been applied. A specially designed lifelike eyeball phantom has been used, constructed from 40 flat sheet LMP-based silicone foils stacked and placed together behind a spherical phantom made by polystyrene, all to reflect the curvature of the real eyeball. Two-dimensional OSL signals were captured and further analyzed from each single silicone foil after irradiation using a dedicated patient collimator and a 58.8 MeV modulated proton beam. The reconstructed 3D proton depth dose distribution matches very well with the clinical treatment plan, allowing for the consideration of the new OSL system for further 3D dosimetry applications within the proton radiotherapy area.


Asunto(s)
Neoplasias , Protones , Humanos , Luminiscencia , Fantasmas de Imagen , Radiometría , Dosificación Radioterapéutica , Siliconas
5.
Int J Mol Sci ; 19(8)2018 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-30065179

RESUMEN

Proton beam irradiation promises therapeutic utility in the management of uveal melanoma. Calcitriol (1,25(OH)2D3)-the biologically active metabolite of vitamin D3-and its precursor, calcidiol (25(OH)D3), exert pleiotropic effects on melanoma cells. The aim of the study was to evaluate the effect of both calcitriol and calcidiol on melanoma cell proliferation and their response to proton beam irradiation. Three melanoma cell lines (human SKMEL-188 and hamster BHM Ma and BHM Ab), pre-treated with 1,25(OH)2D3 or 25(OH)D3 at graded concentrations (0, 10, 100 nM), were irradiated with 0⁻5 Gy and then cultured in vitro. Growth curves were determined by counting the cell number every 24 h up to 120 h, which was used to calculate surviving fractions. The obtained survival curves were analysed using two standard models: linear-quadratic and multi-target single hit. Calcitriol inhibited human melanoma proliferation at 10 nM, while only calcidiol inhibited proliferation of hamster lines at 10 and 100 nM doses. Treatment with either 1,25(OH)2D3 or 25(OH)D3 radio sensitized melanoma cells to low doses of proton beam radiation. The strength of the effect increased with the concentration of vitamin D3. Our data suggest that vitamin D3 may be an adjuvant that modifies proton beam efficiency during melanoma therapy.


Asunto(s)
Calcifediol/farmacología , Calcitriol/farmacología , Melanoma/metabolismo , Animales , Línea Celular Tumoral , Proliferación Celular/efectos de los fármacos , Proliferación Celular/efectos de la radiación , Colecalciferol/farmacología , Cricetinae , Humanos , Terapia de Protones
6.
Acta Oncol ; 56(11): 1406-1412, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28885067

RESUMEN

INTRODUCTION: Proton beam therapy delivers a more conformal dose distribution than conventional radiotherapy, thus improving normal tissue sparring. Increasing linear energy transfer (LET) along the proton track increases the relative biological effectiveness (RBE) near the distal edge of the Spread-out Bragg peak (SOBP). The severity of normal tissue side effects following photon beam radiotherapy vary considerably between patients. AIM: The dual study aim was to identify gene expression patterns specific to radiation type and proton beam position, and to assess whether individual radiation sensitivity influences gene expression levels in fibroblast cultures irradiated in vitro. METHODS: The study includes 30 primary fibroblast cell cultures from patients previously classified as either radiosensitive or radioresistant. Cells were irradiated at three different positions in the proton beam profile: entrance, mid-SOBP and at the SOBP distal edge. Dose was delivered in three fractions × 3.5 Gy(RBE) (RBE 1.1). Cobalt-60 (Co-60) irradiation was used as reference. Real-time qPCR was performed to determine gene expression levels for 17 genes associated with inflammation response, fibrosis and angiogenesis. RESULTS: Differences in median gene expression levels were observed for multiple genes such as IL6, IL8 and CXCL12. Median IL6 expression was 30%, 24% and 47% lower in entrance, mid-SOBP and SOBP distal edge groups than in Co-60 irradiated cells. No genes were found to be oppositely regulated by different radiation qualities. Radiosensitive patient samples had the strongest regulation of gene expression; irrespective of radiation type. CONCLUSIONS: Our findings indicate that the increased LET at the SOBP distal edge position did not generally lead to increased transcriptive response in primary fibroblast cultures. Inflammatory factors were generally less extensively upregulated by proton irradiation compared with Co-60 photon irradiation. These effects may possibly influence the development of normal tissue damage in patients treated with proton beam therapy.


Asunto(s)
Radioisótopos de Cobalto/farmacología , Fibroblastos/metabolismo , Fibrosis/genética , Perfilación de la Expresión Génica/métodos , Regulación de la Expresión Génica/efectos de la radiación , Protones , Células Cultivadas , Relación Dosis-Respuesta en la Radiación , Fibroblastos/citología , Fibroblastos/efectos de la radiación , Fibrosis/diagnóstico , Fibrosis/etiología , Humanos , Transferencia Lineal de Energía
7.
Acta Oncol ; 56(11): 1387-1391, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28830292

RESUMEN

INTRODUCTION: The aim of the present study was to examine the RBE for early damage in an in vivo mouse model, and the effect of the increased linear energy transfer (LET) towards the distal edge of the spread-out Bragg peak (SOBP). METHOD: The lower part of the right hind limb of CDF1 mice was irradiated with single fractions of either 6 MV photons, 240 kV photons or scanning beam protons and graded doses were applied. For the proton irradiation, the leg was either placed in the middle of a 30-mm SOBP, or to assess the effect in different positions, irradiated in 4 mm intervals from the middle of the SOBP to behind the distal dose fall-off. Irradiations were performed with the same dose plan at all positions, corresponding to a dose of 31.25 Gy in the middle of the SOBP. Endpoint of the study was early skin damage of the foot, assessed by a mouse foot skin scoring system. RESULTS: The MDD50 values with 95% confidence intervals were 36.1 (34.2-38.1) Gy for protons in the middle of the SOBP for score 3.5. For 6 MV photons, it was 35.9 (34.5-37.5) Gy and 32.6 (30.7-34.7) Gy for 240 kV photons for score 3.5. The corresponding RBE was 1.00 (0.94-1.05), relative to 6 MV photons and 0.9 (0.85-0.97) relative to 240 kV photons. In the mice group positioned at the SOBP distal dose fall-off, 25% of the mice developed early skin damage compared with 0-8% in other groups. LETd,z = 1 was 8.4 keV/µm at the distal dose fall-off and the physical dose delivered was 7% lower than in the central SOBP position, where LETd,z =1 was 3.3 keV/µm. CONCLUSIONS: Although there is a need to expand the current study to be able to calculate an exact enhancement ratio, an enhanced biological effect in vivo for early skin damage in the distal edge was demonstrated.


Asunto(s)
Protones/efectos adversos , Efectividad Biológica Relativa , Piel/patología , Animales , Relación Dosis-Respuesta en la Radiación , Femenino , Transferencia Lineal de Energía , Ratones , Piel/efectos de la radiación
8.
Radiat Environ Biophys ; 53(4): 745-54, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25037857

RESUMEN

The aim of the study was to determine the relative biological effectiveness (RBE) of a 60-MeV proton radiotherapy beam at the Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN) in Kraków, the first one to operate in Poland. RBE was assessed at the surviving fractions (SFs) of 0.01, 0.1, and 0.37, for normal human fibroblasts from three cancer patients. The cells were irradiated near the Bragg peak of the pristine beam and at three depths within a 28.4-mm spread-out Bragg peak (SOBP). Reference radiation was provided by 6-MV X-rays. The mean RBE value at SF = 0.01 for fibroblasts irradiated near the Bragg peak of pristine beam ranged between 1.06 and 1.15. The mean RBE values at SF = 0.01 for these cells exposed at depths of 2, 15, and 27 mm of the SOBP ranged between 0.95-1.00, 0.97-1.02, and 1.05-1.11, respectively. A trend was observed for RBE values to increase with survival level and with depth in the SOBP: at SF = 0.37 and at the depth of 27 mm, RBE values attained their maximum (1.19-1.24). The RBE values estimated at SF = 0.01 using normal human fibroblasts for the 60-MeV proton radiotherapy beam at the IFJ PAN in Kraków are close to values of 1.0 and 1.1, used in clinical practice.


Asunto(s)
Física Nuclear , Terapia de Protones , Supervivencia Celular/efectos de la radiación , Femenino , Fibroblastos/patología , Fibroblastos/efectos de la radiación , Humanos , Polonia , Efectividad Biológica Relativa , Neoplasias del Cuello Uterino/radioterapia
9.
Radiat Environ Biophys ; 53(1): 203-10, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24213588

RESUMEN

The aim of this work was to determine the concentrations and properties of free radicals in piperacillin, ampicillin, and crystalline penicillin after gamma irradiation. The radicals were studied by electron paramagnetic resonance (EPR) spectroscopy using an X-band spectrometer (9.3 GHz). Gamma irradiation was performed at a dose of 25 kGy. One- and two-exponential functions were fitted to the experimental data, in order to assess the influence of the antibiotics' storage time on the measured EPR lines. After gamma irradiation, complex EPR lines were recorded confirming the presence of a large number of free radicals formed during the irradiation. For all tested antibiotics, concentrations of free radicals and parameters of EPR spectra changed with storage time. The results obtained demonstrate that concentration of free radicals and other spectroscopic parameters can be used to select the optimal parameters of radiation sterilization of ß-lactam antibiotics. The most important parameters are the constants τ (τ (1(A),(I)) and τ (2(A),(I))) and K (K (0(A),(I)), K (1(A),(I)), K (2(A),(I))) of the exponential functions that describe free radicals decay during samples storage.


Asunto(s)
Antibacterianos/química , Radicales Libres/análisis , Rayos gamma , Ampicilina/química , Energía Filtrada en la Transmisión por Microscopía Electrónica , Penicilinas/química , Piperacilina/química , Esterilización
10.
Free Radic Biol Med ; 199: 166-176, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36858326

RESUMEN

The inadequate level of oxygenation in tumors has been shown to correlate not only with greater invasiveness of cancer cells, but also with a reduction in their sensitivity to anticancer therapies. Over the years, many attempts have been made to increase the oxygenation level of cancer, but most of them have been ineffective. We investigated the heterogeneous response of tumor tissue to phospholipid-coated oxygen microbubbles (OMB) in murine tumors in vivo using oxygen and hemoglobin saturation mapping and the influence of OMB treatment on microvasculature, perfusion, and radiotherapy effectiveness. Intravenous administration of OMB followed by ultrasound pulse leads to increased oxygenation of a tumor, found mainly in the vicinity of tumor vessels, while intratumoral delivery resulted in areas of increased pO2 more evenly distributed within the tumor. Furthermore, hemoglobin contributes little to the increase in tumor oxygenation caused by oxygen microbubbles. Extensive vasculature disruption was observed in the groups treated with both oxygen/nitrogen microbubbles and ultrasound pulse. This therapy also led to a reduction in the coverage of the vessels by pericytes, while the density of the microvessels was unchanged. Radiotherapy with a single dose of 12Gy reduced tumor growth by 50% in all treated groups. Unfortunately, at the same time, the number of macroscopic metastases in the lungs increased significantly after intravenous administration of oxygen/nitrogen microbubbles and the application of an ultrasound pulse. In conclusion, ultrasound-sensitive oxygen microbubbles are effective in delivering oxygen to tumor tissue, thus increasing the effectiveness of radiotherapy. However, cavitation effects and destruction of the integrity of tumor vessels result in greater spread of cancer cells in the host organism.


Asunto(s)
Neoplasias de la Mama , Ratones , Humanos , Animales , Femenino , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/tratamiento farmacológico , Microburbujas , Oxígeno , Ultrasonografía , Oximetría
11.
Materials (Basel) ; 16(5)2023 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-36903093

RESUMEN

Modern radiotherapy (RT) techniques, such as proton therapy, require more and more sophisticated dosimetry methods and materials. One of the newly developed technologies is based on flexible sheets made of a polymer, with the embedded optically stimulated luminescence (OSL) material in the form of powder (LiMgPO4, LMP) and a self-developed optical imaging setup. The detector properties were evaluated to study its potential application in the proton treatment plan verification for eyeball cancer. The data showed a well-known effect of lower luminescent efficiency of the LMP material response to proton energy. The efficiency parameter depends on a given material and radiation quality parameters. Therefore, the detailed knowledge of material efficiency is crucial in establishing a calibration method for detectors exposed to mixed radiation fields. Thus, in the present study, the prototype of the LMP-based silicone foil material was tested with monoenergetic uniform proton beams of various initial kinetic energies constituting the so-called spread-out Bragg peak (SOBP). The irradiation geometry was also modelled using the Monte Carlo particle transport codes. Several beam quality parameters, including dose and the kinetic energy spectrum, were scored. Finally, the obtained results were used to correct the relative luminescence efficiency response of the LMP foils for monoenergetic and spread-out proton beams.

12.
Radiat Prot Dosimetry ; 199(15-16): 1937-1940, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37819291

RESUMEN

The radioluminescence (RL) emitted by LiMgPO4 detector under proton beam irradiation was investigated in real time at the radiotherapy facility in the Institute of Nuclear Physics Polish Academy of Sciences in Krakow. The facility uses protons accelerated by the AIC-144 isochronous cyclotron up to the energy of 60 MeV. The measurements of RL were carried out using a remote optical fiber device with a luminophore detector and photomultiplier located at opposite ends of the optical fiber. A thin slice of LiMgPO4 doped with Tm (1.2 mol%) crystal was exposed to the proton beam. The tested detector allowed for the measurement of proton beam current, flux fluence and determination of proton beam time structure parameters. The investigation of LiMgPO4 crystal showed its high sensitivity, fast reaction time to irradiation and possibility of application as the detector for control of proton beam parameters.


Asunto(s)
Ciclotrones , Terapia de Protones , Control de Calidad , Dosificación Radioterapéutica , Radioterapia , Ciclotrones/instrumentación , Ciclotrones/normas , Luminiscencia , Polonia , Terapia de Protones/instrumentación , Terapia de Protones/normas , Protones , Radiactividad , Radioterapia/normas , Dosificación Radioterapéutica/normas , Metales Ligeros
13.
Radiat Prot Dosimetry ; 199(14): 1616-1619, 2023 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-37721070

RESUMEN

Quality control of therapeutic photon beams in the form of postal dose audits based on passive dosemeters is widely used in photon radiotherapy. On the other hand, no standardised dosimetry audit programme for proton centres has been established in Europe so far. We evaluated alanine/EPR dosimetry systems developed at the Istituto Superiore di Sanità (Italy), the Hasselt Universiteit (Belgium) and the Henryk Niewodniczanski Institute of Nuclear Physics Polish Academy of Sciences (Poland) for their applicability as a potential tool for routine mailed dose audits of passively scattered therapeutic proton beams. The evaluation was carried out in the form of an intercomparison. Dosemeters were irradiated in the 70 MeV proton beam at ocular proton therapy facility in the Cyclotron Centre Bronowice at the Henryk Niewodniczanski Institute of Nuclear Physics Polish Academy of Sciences in Krakow. A very good agreement was found between the dose measured by three laboratories and the delivered dose determined with an ionisation chamber. This, together with the inherent properties of alanine, such as non-destructive readout, tissue equivalence, weak energy dependence, dose rate independence and insignificant fading, makes alanine a good candidate for a dosemeter used in postal auditing in proton ocular radiotherapy.


Asunto(s)
Terapia de Protones , Protones , Ojo , Radiometría , Alanina
14.
Klin Oczna ; 114(3): 173-9, 2012.
Artículo en Polaco | MEDLINE | ID: mdl-23373396

RESUMEN

PURPOSE: Presentation of the proton beam radiotherapy (PBR) as a method of treatment of the uveal melanoma patients in the Department of Ophthalmology and Ocular Oncology and Nuclear Physics Institute in Cracow, Poland and their preliminary results. MATERIAL AND METHODS: Nine patients with only choroidal melanoma were treated using PBR between January and April 2011. There were 4 women (44%) and 5 men (56%), a mean age 56 years (38-72). The mean tumor thickness using ultrasounds was 4.14 mm (1.4-9.6 mm). RESULTS: The mean follow-up was 6 months (5-7). The mean tumor thickness after PBR was 2.47 mm (0-9.3 mm). In 2 patients endoresection of irradiated tumor mass was performed with final flat scar. After exclusion of these patients from analysis, the mean thickness was 3.17 mm (1.5-9.3 mm). In 6 patients the visual function was stable. CONCLUSIONS: The preliminary results show that PBR is highly precise method of uveal melanoma treatment achieving high rates of local control. This method necessitates a close co-operation between ophthalmologist, oncologist, radiotherapists, and medical physicist as well as an elaboration of own procedures of planning and treatment. uveal melanoma, radiotherapy, proton-beam radiotherapy.


Asunto(s)
Melanoma/radioterapia , Radioterapia de Alta Energía/métodos , Neoplasias de la Úvea/radioterapia , Adulto , Anciano , Terapia Combinada , Supervivencia sin Enfermedad , Enucleación del Ojo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Melanoma/cirugía , Persona de Mediana Edad , Terapia de Protones , Resultado del Tratamiento , Neoplasias de la Úvea/cirugía , Agudeza Visual
15.
Phys Med Biol ; 67(1)2022 01 17.
Artículo en Inglés | MEDLINE | ID: mdl-34933289

RESUMEN

Objective. Treatment planning based on computer simulations wasproposed to account for the increased relative biological effectiveness (RBE) of proton radiotherapy beams near to the edges of the irradiated volume. Since silicon detectors could be used to validate the results of these simulations, it is important to explore the limitations of this comparison.Approach. Microdosimetric measurements with a MicroPlus Bridge V2 silicon detector (thickness = 10µm) were performed along the Bragg peak of a clinical proton beam. The lineal energy distributions, the dose-mean values, and the RBE calculated with a biological weighting function were compared with PHITS simulations (microdosimetric target = 1µm water sphere), and published clonogenic survivalin vitroRBE data for the V79 cell line. The effect of the silicon-to-water conversion was also investigated by comparing three different methodologies (conversion based on a single value, novel bin-to-bin conversions based on SRIM and PSTAR).Main results. Mainly due to differences in the microdosimetric targets, the experimental dose-mean lineal energy and RBE values at the distal edge were respectively up to 53% and 28% lower than the simulated ones. Furthermore, the methodology chosen for the silicon-to-water conversion was proven to affect the dose-mean lineal energy and the RBE10up to 32% and 11% respectively. The best methodology to compensate for this underestimation was the bin-to-bin silicon-to-water conversion based on PSTAR.Significance. This work represents the first comparison between PHITS-simulated lineal energy distributions in water targets and corresponding experimental spectra measured with silicon detectors. Furthermore, the effect of the silicon-to-water conversion on the RBE was explored for the first time. The proposed methodology based on the PSTAR bin-to-bin conversion appears to provide superior results with respect to commonly used single scaling factors and is recommended for future studies.


Asunto(s)
Terapia de Protones , Método de Montecarlo , Terapia de Protones/métodos , Protones , Silicio , Agua
16.
Phys Med Biol ; 2022 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-35259730

RESUMEN

Objective Proton therapy is gaining popularity because of the improved dose delivery over conventional radiation therapy. The secondary dose to healthy tissues is dominated by secondary neutrons. Commercial rem-counters are valuable instruments for the on-line assessment of neutron ambient dose equivalent (H*(10)). In general, however, a priori knowledge of the type of facility and of the radiation field is required for the proper choice of any survey meter. The novel Mevion S250i Hyperscan synchrocyclotron mounts the accelerator directly on the gantry. It provides a scanned 227 MeV proton beam, delivered in pulses with a pulse width of 10 µs at 750 Hz frequency, which is afterwards degraded in energy by a range shifter modulator system. This environment is particularly challenging for commercial rem-counters; therefore, we tested the reliability of some of the most widespread rem-counters to understand their limits in the Mevion S250i stray neutron field. Approach This work, promoted by the European Radiation Dosimetry Group (EURADOS), describes a rem-counter intercomparison at the Maastro Proton Therapy centre in the Netherlands, which houses the novel Mevion S250i Hyperscan system. Several rem-counters were employed in the intercomparison (LUPIN, LINUS, WENDI-II, LB6411, NM2B-458, NM2B-495Pb), which included simulation of a patient treatment protocol employing a water tank phantom. The outcomes of the experiment were compared with models and data from the literature. Main results We found that only the LUPIN allowed for a correct assessment of H*(10) within a 20% uncertainty. All other rem-counters underestimated the reference H*(10) by factors from 2 to more than 10, depending on the detector model and on the neutron dose per pulse. In pulsed fields, the neutron dose per pulse is a fundamental parameter, while the average neutron dose rate is a secondary quantity. An average 150-200 µSv/GyRBE neutron H*(10) at various positions around the phantom and at distances between 186 cm and 300 cm from it was measured per unit therapeutic dose delivered to the target. Significance Our results are partially in line with results obtained at similar Mevion facilities employing passive energy modulation. Comparisons with facilities employing active energy modulation confirmed that the neutron H*(10) can increase up to more than a factor of 10 when passive energy modulation is employed. The challenging environment of the Mevion stray neutron field requires the use of specific rem-counters sensitive to high-energy neutrons (up to a few hundred MeV) and specifically designed to withstand pulsed neutron fields.

17.
Radiat Prot Dosimetry ; 198(19): 1471-1475, 2022 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-36138419

RESUMEN

The Maastro Proton Therapy Centre is the first European facility housing the Mevion S250i Hyperscan synchrocyclotron. The proximity of the accelerator to the patient, the presence of an active pencil beam delivery system downstream of a passive energy degrader and the pulsed structure of the beam make the Mevion stray neutron field unique amongst proton therapy facilities. This paper reviews the results of a rem-counter intercomparison experiment promoted by the European Radiation Dosimetry Group at Maastro and compares them with those at other proton therapy facilities. The Maastro neutron H*(10) in the room (100-200 µSv/Gy at about 2 m from the isocentre) is in line with accelerators using purely passive or wobbling beam delivery modalities, even though Maastro shows a dose gradient peaked near the accelerator. Unlike synchrotron- and cyclotron-based facilities, the pulsed beam at Maastro requires the employment of rem-counters specifically designed to withstand pulsed neutron fields.


Asunto(s)
Terapia de Protones , Humanos , Terapia de Protones/métodos , Dosis de Radiación , Neutrones , Radiometría/métodos , Ciclotrones , Dosificación Radioterapéutica
18.
Int J Radiat Biol ; 96(10): 1238-1244, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32780616

RESUMEN

PURPOSE: Conventional X-ray radiotherapy induces a pro-inflammatory response mediated by altered expression of inflammation-regulating cytokines. Proton scanning and X-ray irradiation produce distinct changes to cytokine gene expression in vitro suggesting that proton beam therapy may induce an inflammatory response dissimilar to that of X-ray radiation. The purpose of the present study was to determine whether proton scanning beam radiation and conventional X-ray photon radiation would induce differential regulation of circulating cytokines in vivo. MATERIALS AND METHODS: Female CDF1 mice were irradiated locally at the right hind leg using proton pencil beam scanning or X-ray photons. Blood samples were obtained from two separate mice groups. Samples from one group were drawn by retro-orbital puncture 16 months post irradiation, while samples from the other group were drawn 5 and 30 days post irradiation. Concentration of the cytokines IL-6, IL-1ß, IL-10, IL-17A, IFN-γ, and TNFα was measured in plasma using bead-based immunoassays. RESULTS: The cytokines IL-6, IL-1ß, IL-10, IFN-γ, and TNFα were expressed at lower levels in plasma samples from proton-irradiated mice compared with X-ray-irradiated mice 16 months post irradiation. The same cytokines were downregulated in proton-irradiated mice 5 days post irradiation when compared to controls, while at day 30 expression had increased to the same level or higher. X-ray radiation did not markedly change expression levels at days 5 and 30. CONCLUSIONS: The inflammatory response to proton and X-ray irradiation seem to be distinct as the principal pro-inflammatory cytokines are differentially regulated short- and long-term following irradiation. Both the development of normal tissue damage and efficacy of immunotherapy could be influenced by an altered inflammatory response to irradiation.


Asunto(s)
Citocinas/metabolismo , Protones , Animales , Femenino , Inflamación/metabolismo , Ratones , Piel/metabolismo , Piel/efectos de la radiación , Factores de Tiempo , Rayos X
19.
Phys Med Biol ; 65(1): 015008, 2020 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-31569080

RESUMEN

Changes in the relative biological effectiveness (RBE) of the radiation-induced cell killing of human salivary glands (HSG) were assessed along the Bragg peak of a 60 MeV clinical proton beam by means of coupling biophysical models with the results of Monte Carlo radiation transport simulations and experimental measurements with luminescent detectors. The fluence- and dose-mean unrestricted proton LET were determined along the Bragg peak using a recently developed methodology based on the combination of the response of 7LiF:Mg,Ti (MTS-7) and 7LiF:Mg,Cu,P (MCP-7) thermoluminescent detectors. The experimentally assessed LET values were compared with the results of radiation transport simulations using the Monte Carlo code PHITS, showing a good agreement. The cell survival probabilities and RBE were then calculated using the linear-quadratic model with the linear term derived using a phenomenological LET-based model (Carabe A et al 2012 Phys. Med. Biol. 57 1159) in combination with the experimentally-assessed or PHITS-simulated dose mean proton LET values. To the same aim, PHITS simulated microdosimetric spectra were used as input to the modified microdosimetric kinetic model (modified MKM, (Kase et al 2006 Radiat. Res. 166 629-38)). The RBE values calculated with the three aforementioned approaches were compared and found to be in very good agreement between each other, proving that by using dedicated pairs of thermoluminescent detectors it is possible to determine ionization density quantities of therapeutic proton beams which can be applied to predict the local value of the RBE.


Asunto(s)
Muerte Celular , Simulación por Computador , Modelos Estadísticos , Protones , Glándulas Salivales/patología , Dosimetría Termoluminiscente/instrumentación , Células Cultivadas , Relación Dosis-Respuesta en la Radiación , Humanos , Cinética , Método de Montecarlo , Efectividad Biológica Relativa , Glándulas Salivales/efectos de la radiación
20.
Sci Rep ; 9(1): 7008, 2019 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-31065009

RESUMEN

Cellular response to non-lethal radiation stress include perturbations in DNA repair, angiogenesis, migration, and adhesion, among others. Low-LET proton beam radiation has been shown to induce somewhat different biological response than photon radiation. For example, we have shown that non-lethal doses of proton beam radiation inhibited migration of cells and that this effect persisted long-term. Here, we have examined cellular elasticity and actin cytoskeleton organization in BLM cutaneous melanoma and Mel270 uveal melanoma cells. Proton beam radiation increased cellular elasticity to a greater extent than X-rays and both types of radiation induced changes in actin cytoskeleton organization. Vimentin level increased in BLM cells after both types of radiation. Our data show that cell elasticity increased substantially after low-LET proton beam and persisted long after radiation. This may have significant consequences for the migratory properties of melanoma cells, as well as for the cell susceptibility to therapy.


Asunto(s)
Citoesqueleto de Actina/efectos de la radiación , Melanoma/metabolismo , Terapia de Protones/métodos , Neoplasias Cutáneas/metabolismo , Neoplasias de la Úvea/metabolismo , Vimentina/metabolismo , Citoesqueleto de Actina/metabolismo , Línea Celular Tumoral , Movimiento Celular/efectos de la radiación , Proliferación Celular/efectos de la radiación , Supervivencia Celular/efectos de la radiación , Elasticidad/efectos de la radiación , Regulación Neoplásica de la Expresión Génica/efectos de la radiación , Humanos , Melanoma/radioterapia , Neoplasias Cutáneas/radioterapia , Regulación hacia Arriba , Neoplasias de la Úvea/radioterapia , Melanoma Cutáneo Maligno
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA