Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Eur J Cardiothorac Surg ; 54(4): 752-761, 2018 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-29617804

RESUMEN

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) in patients with low coronary heights is generally denied but is not impossible. Information about these high-risk procedures is sparse. METHODS: Since May 2008, data of more than 3000 patients who had TAVI were prospectively collected in the institutional TAVI Karlsruhe registry. Characteristics, peri- and postoperative outcome of patients with low coronary heights of ≤7 mm were analysed according to the Valve Academic Research Consortium-2. RESULTS: Eighty-six patients with an average coronary height of 6.4 ± 1.1 mm (mean age 81.0 ± 5.3 years, logistic EuroSCORE I 19.6 ± 13.3%) were treated. TAVI was performed in 72 transfemoral (83.7%) and 14 transapical (16.3%) cases using 44 CoreValve/Evolut R (51.2%), 21 Sapien XT/S3 (24.4%), 14 ACURATE (16.3%), 5 Lotus (5.8%) and 2 Portico (2.3%) prostheses. Ten procedures were valve-in-valve (VinV) TAVI (VinV, 11.6%). The 72-h, 30-day, 1-year and follow-up (3.0 ± 1.6 years) mortality rates were 2.3%, 8.0%, 10.5% and 26.7%, respectively. Within 30 days, 4 cardiac deaths and 3 non-cardiac deaths occurred (4.7% and 3.5%). Three coronary obstructions (3.5%) occurred-2 during VinV TAVI. One patient was connected to extracorporeal circulation that could not be weaned later due to an unsuccessful percutaneous coronary intervention. Another patient, the only conversion (1.2%), required delayed surgical valve replacement. The third patient died of right heart failure after aortic dissection. The procedural success rate was 95.3%. VinV procedures were associated with increased follow-up deaths (P < 0.001; hazard ratio 7.96). CONCLUSIONS: Coronary-related complications in TAVI procedures in patients with coronary heights ≤7 mm occurred less frequently, but once they occurred, they were serious. These TAVI procedures are feasible, with a high procedural success rate, but meticulous preoperative planning should be mandatory. In VinV procedures, the follow-up mortality rate is increased; therefore, we do not recommend these procedures.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Oclusión Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Bioprótesis , Angiografía Coronaria , Oclusión Coronaria/etiología , Estudios de Factibilidad , Femenino , Fluoroscopía , Estudios de Seguimiento , Alemania/epidemiología , Humanos , Incidencia , Masculino , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Tasa de Supervivencia/tendencias , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA