Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 104(1): 115-124, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38764320

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat severe aortic stenosis in younger patients. Accordingly, lifetime management regarding future reintervention and coronary access is a concern. AIMS: To assess the impact of commissural alignment on ACURATE neo2 transcatheter aortic valve (TAV) performance. METHODS: COMALIGN-neo2 was an observational, retrospective study enrolling consecutive TAVR patients treated with the ACURATE neo2 (October 2021 to October 2022). The degree of commissural (mis)-alignment (CMA) with the native aortic valve commissures was determined and transvalvular gradient, effective orifice area, patient-prosthesis mismatch (PPM), and aortic regurgitation (AR) were assessed. RESULTS: Among 825 patients, the mean age was 80.7 years and 42% were female. Commissural alignment was achieved in 60% of cases; mild (26%), moderate (9%), and severe misalignment (5%) were found less often. Severe PPM occurred more frequently in patients with severe CMA (14.7%) compared to aligned valves (p = 0.034). By multivariate analysis, severe CMA (odds ratio [OR]: 3.12, 95% confidence interval [CI] [1.09-8.90]; p = 0.033) and lack of postdilatation (OR: 3.85, [1.33-11.1]; p = 0.012) were associated with severe PPM. Higher rates of ≥mild AR (51.4%) were found in TAVs implanted with severe CMA compared to aligned (34.3%), mildly (38.1%) or moderately (36.0%) misaligned TAVs (p = 0.030). Multivariate analysis identified severe CMA (OR: 2.05, [1.05-4.02]; p = 0.037) to be an independent predictor of ≥mild AR. CONCLUSIONS: COMALIGN-neo2 is the largest study to date assessing the impact of commissural alignment on acute TAV performance. Severe CMA with the ACURATE neo2 platform was associated with worse valve hemodynamics and increased risk for mild AR.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Hemodinámica , Diseño de Prótesis , Recuperación de la Función , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Masculino , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Anciano de 80 o más Años , Anciano , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Resultado del Tratamiento , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo
2.
Catheter Cardiovasc Interv ; 99(3): 723-729, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34156742

RESUMEN

OBJECTIVES: To investigate the outcomes of deferred coronary revascularization in patients with non-significant in-stent restenosis (ISR) by physiological assessment. BACKGROUND: The pathophysiology and natural history of ISR is markedly different from de-novo stenoses. There is a paucity of data on the safety of deferral of revascularization of ISR using physiological assessment. METHODS: In this single centre study, using a propensity-score matched analysis, we compared the long-term clinical outcomes of patients with ISR and de-novo disease deferred based on intracoronary physiology. Matching was on a 1:2 basis of ISR to de-novo stenosis. The primary end point was major adverse cardiovascular events (MACE) a composite of all-cause mortality, target lesion revascularization or target vessel myocardial infarction at 36 months. RESULTS: Matched cohorts of 56 ISR and 112 de-novo stenoses were analyzed. The median percentage stenosis was 50% in both groups (p = 0.403). Deferral was based on fractional flow reserve (FFR). The mean FFR was 0.86 across both groups (p = 0.942). At 36-months, freedom from MACE was similar between groups; 86.2% versus 92.8% log rank p=0.180 for ISR and de-novo lesions, respectively. Neither were there differences in the individual components of MACE. CONCLUSIONS: Deferral of coronary revascularization in patients with ISR based on its functional impact is associated to similar long-term safety as in de-novo coronary stenosis.


Asunto(s)
Reestenosis Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Constricción Patológica/complicaciones , Angiografía Coronaria/efectos adversos , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Estenosis Coronaria/complicaciones , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/terapia , Reserva del Flujo Fraccional Miocárdico/fisiología , Humanos , Revascularización Miocárdica/efectos adversos , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 98(4): E617-E625, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33856097

RESUMEN

BACKGROUND: Very few data exist on percutaneous mitral valve repair (PMVr) in unstable patients with concomitant moderate-severe mitral regurgitation (MR). The purpose of this systematic review was to evaluate baseline characteristics, management and clinical outcomes of critically ill patients undergoing PMVr with MitraClip. METHODS: We conducted a systematic review of the published data on MitraClip from its first use in 2003 to December 2020. Studies referring to critically ill patients in cardiogenic shock or acute refractory pulmonary edema were included. A total of 40 publications including 254 patients with significant MR (Grade 4 in 91%) were included. RESULTS: Mean age was 70 ± 12 years with mean Euroscore II and STS of 21 ± 13 and 20.5 ± 16, respectively. Clinical presentation was with cardiogenic shock and acute myocardial infarction in 72.8 and 60.0% of patients, respectively. Device success was achieved in 238 (93.7%) patients with a significant reduction in MR (Grade ≤ 2 in 91.8%, p < .001). The median weaning time from the procedure, to discontinuation of mechanical circulatory or respiratory support, was 2 days (IQR 1-4), with an in-hospital mortality and non-fatal complication rate of 12.6 and 9.1%, respectively. Kaplan-Meier curves estimated an overall mortality rate of 39.1% at 12-month follow-up, with persistent reduction in MR severity for survivors (Grade ≤ 2 in 81.3%) and one case of mitral valve reintervention. CONCLUSIONS: Percutaneous mitral valve repair with MitraClip device is a technically feasible and potentially viable management option in high-risk patients with cardiogenic shock or refractory pulmonary edema and concomitant moderate-severe MR. Prospective trials are required to confirm these findings, and definitively determine the value of MitraClip in hemodynamically unstable patients.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
4.
J Card Surg ; 36(1): 31-39, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33085128

RESUMEN

OBJECTIVE: The heart team (HT) approach plays a key role in selecting the optimal treatment strategy for patients with aortic stenosis (AS). However, little is known about the HT decision process and its impact on outcomes. The aim of this study was to identify the factors associated with the HT decision and evaluate clinical outcomes according to the treatment choice. METHODS: The study included a total of 286 consecutive patients with AS referred for discussion in the weekly HT meeting in a cardiovascular institute over 2 years. Patients were stratified according to the selected therapeutic approach: medical treatment (MT), surgical (SAVR), or transcatheter (TAVR) aortic valve replacement. Baseline characteristics involved in making a therapeutic choice were identified and a decision-making tree was built using classification and regression tree methodology. RESULTS: Based on HT discussion, 53 patients were assigned to SAVR, 210 to TAVR, and 23 to MT. Older patients (≥88 years old) were mainly assigned to TAVR or MT according to the logistic EuroSCORE (

Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Factores de Riesgo , Resultado del Tratamiento
5.
Int Heart J ; 62(2): 274-281, 2021 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-33731529

RESUMEN

The COVID-19 pandemic severely disrupted cardiovascular care during the spring of 2020 in Europe. Our study analyzed the clinical profile, COVID-19 impact, and 30-day prognosis of invasively managed patients with acute coronary syndrome (ACS) compared to a historical cohort.All invasively managed ACS patients from March 1st to April 30th, 2020 were compared to a cohort from the same timeframe of 2019 (n = 316). COVID-19 confirmed cases were defined by a positive SARS-CoV-2 polymerase chain reaction (PCR) test (CoV+). The primary outcome was all-cause 30-day mortality and multivariable predictors of this outcome.A 40.4% reduction in ACS patients was noted (198 cases in 2019 to 118 in 2020), and 11% of 2020 ACS patients were CoV+. Baseline characteristics were similar between groups. There were significantly more in-hospital patients with ACS (15.3% versus 6.1%, P = 0.007), and fewer patients were found to have a culprit lesion (58.5% versus 74.2%, P = 0.004) in 2020 compared to 2019. Thirty-day mortality in 2020 (7%) was not different from that in 2019 (4.2%), P = 0.294, but it was significantly higher in CoV+ patients (23.1%) compared to that in negative SARS-CoV-2 PCR test (CoV-) patients (5%), P = 0.047, in the 2020 group. In the multivariate analysis, CoV+ was an independent mortality predictor (OR = 9.8, 95% CI = 1.48-64.78), along with the left ventricular ejection fraction (LVEF) (OR = 0.91, 95% CI = 0.86-0.97), P = 0.0006.This study found increased 30-day mortality of invasively managed CoV+ ACS patients compared to that of CoV- patients during the 2020 COVID-19 spring outbreak. In the multivariable analysis, a SARS-CoV-2 positive test was independently associated with 30-day mortality. Further investigations of the underlying physiopathological relations between COVID-19 and ACS are warranted.


Asunto(s)
Síndrome Coronario Agudo/mortalidad , Síndrome Coronario Agudo/terapia , COVID-19/epidemiología , Brotes de Enfermedades , Síndrome Coronario Agudo/diagnóstico , Anciano , COVID-19/diagnóstico , COVID-19/terapia , Estudios de Cohortes , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Revascularización Miocárdica , Intervención Coronaria Percutánea , Pronóstico , España , Volumen Sistólico , Tasa de Supervivencia
6.
Circulation ; 139(23): 2685-2702, 2019 06 04.
Artículo en Inglés | MEDLINE | ID: mdl-31157994

RESUMEN

The presence of a small aortic annulus poses a considerable challenge in the management of patients with severe aortic stenosis, especially in elderly women, where it is a very frequent finding. The optimal approach for treating these patients remains controversial, and several surgical strategies such as aortic root enlargement, supra-annular stented prosthetic valves, stentless bioprosthesis, and sutureless bioprostheses have been proposed to improve valve hemodynamics and clinical outcomes. More recently, transcatheter aortic valve replacement has emerged as a valid alternative for the treatment of aortic stenosis and excellent valve hemodynamic results have been observed among patients with a small aortic annulus. The purpose of this review is to provide an overview of the current definition, prevalence, and clinical impact of small aortic annulus in patients with aortic stenosis, and evaluate the different therapeutic strategies currently available to improve valve hemodynamics and outcomes in this population.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Procedimientos Quirúrgicos sin Sutura , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Bioprótesis , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Recuperación de la Función , Factores de Riesgo , Procedimientos Quirúrgicos sin Sutura/efectos adversos , Procedimientos Quirúrgicos sin Sutura/instrumentación , Procedimientos Quirúrgicos sin Sutura/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
7.
Int Heart J ; 61(4): 843-847, 2020 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-32684589

RESUMEN

Paravalvular leak (PVL) is a serious complication of surgical valve replacement, often affecting elderly, multimorbid, high-risk patients. The risk of surgical intervention is often prohibitive in these cases, and so percutaneous PVL closure emerged as a feasible and effective management strategy, with a low complication rate. Specific devices for closure of PVL's are currently not widely available, and so PVLs are closed using generic vascular closure devices, which may result in residual paravalvular regurgitation or even closure device displacement. Although rare, late displacement of the closure device with prosthetic impingement can be life threatening, requiring urgent intervention.We present a case of a seventy-year-old gentleman with rheumatic heart disease and multiple previous mechanical aortic and mitral valve replacements. After repeated admissions for decompensated heart failure, secondary to paravalvular mitral regurgitation, a percutaneous paravalvular leak closure was performed with successful reduction of the leak. He represented 30 days later with cardiogenic shock and multiorgan failure secondary to torrential central mitral regurgitation caused by late displacement of the closure device with mitral prosthesis impingement. Due to an excessively high surgical risk, his case was successfully managed percutaneously with retrieval of the displaced device and closure of the PVL using two Amplatzer Vascular Plug III devices. At the six-month review, he remains asymptomatic.Percutaneous PVL closure is an effective strategy for patients with prohibitive surgical risk. Late closure device displacement can be a life-threatening complication. Our case demonstrates that percutaneous management of this complication is feasible even in patients presenting in extremis.


Asunto(s)
Procedimientos Endovasculares , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Complicaciones Posoperatorias/cirugía , Falla de Prótesis , Anciano , Humanos , Masculino , Insuficiencia de la Válvula Mitral/etiología , Complicaciones Posoperatorias/etiología
8.
EuroIntervention ; 20(10): e656-e668, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38776142

RESUMEN

BACKGROUND: Coronary calcification negatively impacts optimal stenting. Intravascular lithotripsy (IVL) is a new calcium modification technique. AIMS: We aimed to assess the impact of different calcium morphologies on IVL efficacy. METHODS: This was a prospective, multicentre study (13 tertiary referral centres). Optical coherence tomography (OCT) was performed before and after IVL, and after stenting. OCT-defined calcium morphologies were concentric (mean calcium arc >180°) and eccentric (mean calcium arc ≤180°). The primary outcomes were angiographic success (residual stenosis <20%) and the presence of fracture by OCT in concentric versus eccentric lesions. RESULTS: Ninety patients were included with a total of 95 lesions: 47 concentric and 48 eccentric. The median number of pulses was 60 (p=1.00). Following IVL, the presence of fracture was not statistically different between groups (79.0% vs 66.0% for concentric vs eccentric; p=0.165). The number of fractures/lesion (4.2±4.4 vs 2.3±2.8; p=0.018) and ≥3 fractures/lesion (57.1% vs 34.0%; p=0.029) were more common in concentric lesions. Angiographic success was numerically but not statistically higher in the concentric group (87.0% vs 76.6%; p=0.196). By OCT, no differences were noted in final minimum lumen area (5.9±2.2 mm2 vs 6.2±2.1 mm2; p=0.570), minimum stent area (5.9±2.2 mm² vs 6.25±2.4 mm2; p=0.483), minimum stent expansion (80.9±16.7% vs 78.2±19.8%), or stent expansion at the maximum calcium site (100.6±24.2% vs 95.8±27.3%) (p>0.05 for all comparisons of concentric vs eccentric, respectively). Calcified nodules were found in 29.5% of lesions; these were predominantly non-eruptive (57%). At the nodule site, dissection was more common than fracture with stent expansion of 103.6±27.2%. CONCLUSIONS: In this prospective, multicentre study, the effectiveness of IVL followed by stenting was not significantly affected by coronary calcium morphology.


Asunto(s)
Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Litotricia , Tomografía de Coherencia Óptica , Calcificación Vascular , Humanos , Litotricia/métodos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/terapia , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Stents , Intervención Coronaria Percutánea/métodos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Calcio
9.
Front Cardiovasc Med ; 10: 1195397, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37229228

RESUMEN

Encouraged by randomized controlled trials demonstrating non-inferiority of transfemoral transcatheter aortic valve implantation (TAVI) compared to surgical aortic valve replacement (SAVR) across all surgical risk categories, there has been a dramatic increase in the use of TAVI in a younger patient cohort with severe aortic stenosis, endorsed by both European and American Cardiac Societies. However, the standard use of TAVI in younger, less co-morbid patients with a longer life expectancy can only be supported if there is sound data demonstrating long-term durability of transcatheter aortic valves (TAVs). In this article, we have reviewed available randomized and observational registry clinical data pertaining to TAV long-term durability, placing emphasis on trials and registries using the new standardized definitions of bioprosthetic valve dysfunction (BVD) and bioprosthetic valve failure (BVF). Despite inherent difficulties in interpreting the available data, the determination reached is that the risk of structural valve deterioration (SVD) is potentially lower after TAVI than SAVR at 5 to 10 years, and that the two treatment modalities have a similar risk of BVF. This supports the adoption of TAVI in younger patients evident in current practice. However, the routine use of TAVI in younger patients with bicuspid aortic valve stenosis should be cautioned due to insufficient long-term TAV durability data in this particular patient population. Finally, we highlight the importance of future research into the unique potential mechanisms that can potentially contribute to TAV degeneration.

10.
Rev Esp Cardiol (Engl Ed) ; 76(10): 767-773, 2023 Oct.
Artículo en Inglés, Español | MEDLINE | ID: mdl-36804557

RESUMEN

INTRODUCTION AND OBJECTIVES: The cusp overlap technique (COT) has been proposed to reduce conduction disturbances (CD) after transcatheter aortic valve implantation (TAVI) with self-expanding supra-annular devices, but there are scarce data on COT with intra-annular valves. The aim of this study was to determine whether the use of the COT during Portico implantation results in higher valve implantation and lower rates of CD. METHODS: We included 85 patients undergoing TAVI with the Portico FlexNav system: 43 retrospective patients using the standard 3-cusp view and 42 prospective patients with the COT. Primary endpoints were implantation depth and new-onset CD (composite outcome of new-onset left bundle branch block and new permanent pacemaker implantation). RESULTS: COT resulted in a higher implantation depth (noncoronary cusp: 4.9±3.9 vs 7.4±3.0; P=.005) and lower new-onset CD (31.0% vs 58.1%; P=.012), with a tendency toward a lower need for permanent pacemaker implantation (14.3% vs 30.2%, P=.078; 7.7% vs 31.0%; P=.011 in patients without pre-existing right bundle branch block). Transvalvular aortic gradients were slightly lower with COT (8.7±3.7 vs 11.0±6.1; P=.044). There were no differences in technical success or major procedure-related complications. On multivariate analysis, COT use was associated with a lower risk of new-onset CD. CONCLUSIONS: Use of the COT during Portico implantation is feasible and facilitates a higher valve implant, which in turn may help to reduce rates of new-onset CD.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Estudios Prospectivos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Trastorno del Sistema de Conducción Cardíaco , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
11.
Rev Esp Cardiol (Engl Ed) ; 76(8): 600-608, 2023 Aug.
Artículo en Inglés, Español | MEDLINE | ID: mdl-36669732

RESUMEN

INTRODUCTION AND OBJECTIVES: Concomitant coronary artery disease (CAD) is prevalent among aortic stenosis patients; however the optimal therapeutic strategy remains debated. We investigated periprocedural outcomes among patients undergoing transcatheter aortic valve implantation with percutaneous coronary intervention (TAVI/PCI) vs surgical aortic valve replacement with coronary artery bypass grafting (SAVR/CABG) for aortic stenosis with CAD. METHODS: Using discharge data from the Spanish National Health System, we identified 6194 patients (5217 SAVR/CABG and 977 TAVI/PCI) between 2016 and 2019. Propensity score matching was adjusted for baseline characteristics. The primary outcome was in-hospital all-cause mortality. Secondary outcomes were in-hospital complications and 30-day cardiovascular readmission. RESULTS: Matching resulted in 774 pairs. In-hospital all-cause mortality was more common in the SAVR/CABG group (3.4% vs 9.4%, P <.001) as was periprocedural stroke (0.9% vs 2.2%; P=.004), acute kidney injury (4.3% vs 16.0%, P <.001), blood transfusion (9.6% vs 21.1%, P <.001), and hospital-acquired pneumonia (0.1% vs 1.7%, P=.001). Permanent pacemaker implantation was higher for matched TAVI/PCI (12.0% vs 5.7%, P <.001). Lower volume centers (< 130 procedures/y) had higher in-hospital all-cause mortality for both procedures: TAVI/PCI (3.6% vs 2.9%, P <.001) and SAVR/CABG (8.3 vs 6.8%, P <.001). Thirty-day cardiovascular readmission did not differ between groups. CONCLUSIONS: In this large contemporary nationwide study, percutaneous management of aortic stenosis and CAD with TAVI/PCI had lower in-hospital mortality and morbidity than surgical intervention. Higher volume centers had less in-hospital mortality in both groups. Dedicated national high-volume heart centers warrant further investigation.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Implantación de Prótesis de Válvulas Cardíacas , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Factores de Riesgo
12.
Cardiovasc Revasc Med ; 52: 59-66, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36878760

RESUMEN

BACKGROUND: Intracoronary lithotripsy (IVL) is a safe and effective treatment for coronary calcification. Angiographic and intracoronary imaging follow-up have not yet been described. We aimed to describe the mid-term angiographic outcomes following IVL. METHODS: Patients successfully treated with IVL in two tertiary referral hospitals were included. Repeat angiography and intracoronary imaging was performed. Quantitative coronary angiography (QCA) and optical coherence tomography (OCT) analyses were performed using dedicated workstations. RESULTS: Twenty patients were included; mean age 67.1 years, left anterior descending artery 55 %. Median IVL balloon size was 3.0 mm and a median of 60 pulses were delivered per vessel. Percentage stenosis by QCA was 60 % [IQR 51-70] reducing to 20 % post stenting (p < 0.001). On OCT, 88.9 % had circumferential calcium. IVL resulted in fractures in 88.9 %. Resulting minimum stent expansion was 91.75 % [IQR 81.5-108]. Follow-up was at a median of 22.7 months [IQR16.4-25.5]. Percentage stenosis by QCA was 22.5 % [IQR 14-30] and not significantly different from the index procedure (p > 0.05). Minimum stent expansion by OCT was 85 % [IQR 72-97]. Late luminal loss was 0.15 mm [IQR -0.25 to 0.69]. Binary angiographic instent restenosis (ISR) was 10 % (2 of 20 patients). OCT demonstrated a predominantly homogenous neointimal pattern with high backscatter. CONCLUSION: Following successful IVL treatment, repeat angiography demonstrated preserved stent parameters in the majority of patients with favorable vascular healing properties by OCT. A binary restenosis rate of 10 % was observed. These results suggest durable results following IVL treatment of severe coronary calcification however larger studies are warranted.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Litotricia , Calcificación Vascular , Humanos , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Centros de Atención Terciaria , Angioplastia Coronaria con Balón/efectos adversos , Constricción Patológica , Angiografía Coronaria/métodos , Resultado del Tratamiento , Stents , Litotricia/efectos adversos , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/terapia , Calcificación Vascular/etiología
13.
Eur Heart J Qual Care Clin Outcomes ; 9(8): 768-777, 2023 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-36637410

RESUMEN

AIMS: Prediction of adverse events in mid-term follow-up after transcatheter aortic valve implantation (TAVI) is challenging. We sought to develop and validate a machine learning model for prediction of 1-year all-cause mortality in patients who underwent TAVI and were discharged following the index procedure. METHODS AND RESULTS: The model was developed on data of patients who underwent TAVI at a high-volume centre between January 2013 and March 2019. Machine learning by extreme gradient boosting was trained and tested with repeated 10-fold hold-out testing using 34 pre- and 25 peri-procedural clinical variables. External validation was performed on unseen data from two other independent high-volume TAVI centres. Six hundred four patients (43% men, 81 ± 5 years old, EuroSCORE II 4.8 [3.0-6.3]%) in the derivation and 823 patients (46% men, 82 ± 5 years old, EuroSCORE II 4.7 [2.9-6.0]%) in the validation cohort underwent TAVI and were discharged home following the index procedure. Over the 12 months of follow-up, 68 (11%) and 95 (12%) subjects died in the derivation and validation cohorts, respectively. In external validation, the machine learning model had an area under the receiver-operator curve of 0.82 (0.78-0.87) for prediction of 1-year all-cause mortality following hospital discharge after TAVI, which was superior to pre- and peri-procedural clinical variables including age 0.52 (0.46-0.59) and the EuroSCORE II 0.57 (0.51-0.64), P < 0.001 for a difference. CONCLUSION: Machine learning based on readily available clinical data allows accurate prediction of 1-year all-cause mortality following a successful TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Lactante , Anciano , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía
14.
Diabetes Ther ; 14(11): 1853-1865, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37665429

RESUMEN

INTRODUCTION: Sodium-glucose type 2 cotransporter inhibitors (SGLT2-I) have shown solid benefits in reducing cardiovascular mortality and admissions for heart failure in patients with type 2 diabetes mellitus (T2DM) and cardiovascular disease. However, no specific studies exist in patients with high-risk coronary artery disease (CAD). METHODS: Single-center, retrospective, observational study including patients with T2DM and a new diagnosis of extensive CAD (defined as left main disease or three main coronary vessel disease). Patients were recruited from 2015 until 2020, with a follow-up of at least 12 months. The primary outcome was to compare all-cause mortality in patients treated with or without SGLT2-I at discharge and adjusted by inverse probability of treatment weighting (IPTW) propensity score. RESULTS: A total of 420 patients were included: 104 (24.7%) were treated with SGLT2-I and 316 (75.3%) were not (non-SGLT2-I group). The presentation was acute coronary syndrome in 44.3%. The mean age was 71.2 ± 10.5 years. The mean left ventricular ejection fraction was 51.5 ± 12.5%, and the mean estimated glomerular filtration rate was 73.9 ± 22 ml/min. After a mean follow-up of 3 ± 1.6 years, all-cause mortality was 16.4%, and cardiovascular mortality was 9.5%. After IPTW, the risk of all-cause death was lower in the SGLT2-I group with a hazard ratio of 0.32 (95% confidence interval 0.12-0.81), p = 0.016. With regard to secondary outcomes, patients in the SGLT2-I group were associated with less renal function deterioration but an increase in unplanned revascularizations. CONCLUSIONS: In patients with T2DM and extensive CAD, treatment with SGLT2-I after discharge was associated with a reduced risk of all-cause death.

15.
J Clin Med ; 12(24)2023 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-38137816

RESUMEN

This review article describes in depth the current usefulness of transesophageal echocardiography in patients who undergo transcatheter aortic valve replacement. Pre-intervention, 3D-transesophageal echocardiography allows us to accurately evaluate the aortic valve morphology and to measure the valve annulus, helping us to choose the appropriate size of the prosthesis, especially useful in cases where the computed tomography is not of adequate quality. Although it is not currently used routinely during the intervention, it remains essential in those cases of greater complexity, such as for patients with greater calcification and bicuspid valve, mechanical mitral prosthesis, and "valve in valve" procedures. Three-dimensional transesophageal echocardiography is the best technique to detect and quantify paravalvular regurgitation, a fundamental aspect to decide whether immediate valve postdilation is needed. It also allows to detect early any immediate complications such as cardiac tamponade, aortic hematoma or dissection, migration of the prosthesis, malfunction of the prosthetic leaflets, or the appearance of segmental contractility disorders due to compromise of the coronary arteries ostium. Transesophageal echocardiography is also very useful in follow-up, to check the proper functioning of the prosthesis and to rule out complications such as thrombosis of the leaflets, endocarditis, or prosthetic degeneration.

16.
Rev Esp Cardiol (Engl Ed) ; 76(3): 165-172, 2023 Mar.
Artículo en Inglés, Español | MEDLINE | ID: mdl-35850485

RESUMEN

INTRODUCTION AND OBJECTIVES: Changes in sex hormone levels are a known triggering factor for spontaneous coronary artery dissection (SCAD) in women. However, it is unknown whether exposure to exogenous hormone therapy (HT) at the time of SCAD presentation modifies the clinical course of this condition. We investigated the association between HT in female patients presenting with SCAD and short-term clinical outcomes. METHODS: We enrolled consecutive patients presenting with SCAD from the DISCO-IT/SPA (dissezioni spontanee coronariche Italian-Spanish) registry. Women on HT (estrogens, progestagens, or gonadotropins) at the time of presentation were identified, and their clinical characteristics and short-term outcomes were compared with those not receiving active HT. The outcome measure was nonfatal myocardial infarction and/or unplanned percutaneous coronary intervention during the first 28 days after the index catheterization. RESULTS: Of 224 women presenting with SCAD (mean age 52.0±10.0 years), 39 (17.4%) were currently using HT while 185 (82.6%) were not. No significant differences were noted in the baseline demographics, clinical presentation, angiographic features, or initial treatment received between the 2 groups. All patients on systemic HT (n=36, 92%) discontinued it at the time of diagnosis. The composite outcome occurred in 7 (17.9%) patients with prior HT compared with 14 (7.6%) without (P=.039). After multivariable adjustment, HT remained associated with the composite outcome recorded in the first 28 days of follow-up (HR, 3.53; 95%CI, 1.30-9.61; P=.013). CONCLUSIONS: In women with SCAD, exposure to HT at the time of clinical presentation was associated with short-term recurrent cardiovascular events such as nonfatal myocardial infarction and/or unplanned percutaneous revascularization.


Asunto(s)
Anomalías de los Vasos Coronarios , Infarto del Miocardio , Intervención Coronaria Percutánea , Enfermedades Vasculares , Humanos , Femenino , Adulto , Persona de Mediana Edad , Vasos Coronarios , Enfermedades Vasculares/diagnóstico , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Anomalías de los Vasos Coronarios/diagnóstico , Hormonas , Angiografía Coronaria , Factores de Riesgo
17.
Rev Esp Cardiol (Engl Ed) ; 76(7): 503-510, 2023 Jul.
Artículo en Inglés, Español | MEDLINE | ID: mdl-35934294

RESUMEN

INTRODUCTION AND OBJECTIVES: Transthyretin cardiac amyloidosis (ATTR-CA) patients often have atrial fibrillation and increased bleeding/thrombogenic risks. We aimed to evaluate outcomes of left atrial appendage closure (LAAC) compared with patients without a known diagnosis of CA. METHODS: Comparison at long-term of patients diagnosed with ATTR-CA who underwent LAAC between 2009 and 2020 and those without a known diagnosis of CA. RESULTS: We studied a total of 1159 patients. Forty patients (3.5%) were diagnosed with ATTR-CA; these patients were older and had more comorbidities, higher HAS-BLED and CHA2DS2-VASc scores, and lower left ventricular function. Successful LAAC was achieved in 1137 patients (98.1%) with no differences between groups. Regarding in-hospital and follow-up complications, there were no differences between the groups in ischemic stroke (5% vs 2.5% in those without a known diagnosis of CA; P=.283), hemorrhagic stroke (2.5% and 0.8% in the control group; P=.284), major or minor bleeding. At the 2-year follow-up, there were no significant differences in mortality (ATTR-CA: 20% vs those without known CA: 13.6%, 0.248); however, the at 5-year follow-up, ATTR-CA patients had higher mortality (40% vs 19.2%; P <.001) but this difference was unrelated to hemorrhagic complications or ischemic stroke. CONCLUSIONS: LAAC could reduce the risk of bleeding complications and ischemic cerebrovascular events without increasing the rate of early or mid-term complications. Although long-term survival was impaired in ATTR-CA patients, it was comparable to that of patients without a known diagnosis of CA at the 2-year follow-up, suggesting that LAAC for patients with ATTR-CA might not be futile.


Asunto(s)
Amiloidosis , Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Hemorragia/complicaciones , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Amiloidosis/complicaciones , Amiloidosis/diagnóstico , Resultado del Tratamiento
18.
Heart ; 109(18): 1401-1406, 2023 08 24.
Artículo en Inglés | MEDLINE | ID: mdl-37217297

RESUMEN

INTRODUCTION: Estimation of peri-procedural risk in patients with tricuspid regurgitation (TR) undergoing isolated tricuspid valve surgery (ITVS) is of paramount importance. The TRI-SCORE is a new surgical risk scale specifically developed for this purpose, which ranged from 0 to 12 points and included eight parameters: right-sided heart failure signs, daily dose of furosemide ≥125 mg, glomerular filtration rate <30 mL/min, elevated bilirubin (with a value of 2 points), age ≥70 years, New York Heart Association Class III-IV, left ventricular ejection fraction <60% and moderate/severe right ventricular dysfunction (with a value of 1 point). The objective of the study was to evaluate the performance of the TRI-SCORE in an independent cohort of patients undergoing ITVS. METHODS: A retrospective observational study was performed in four centres, including consecutive adult patients undergoing ITVS for TR between 2005 and 2022. The TRI-SCORE and the traditional risk scores used in cardiac surgery (Logistic EuroScore (Log-ES) and EuroScore-II (ES-II)) were applied for each patient, and discrimination and calibration of the three scores were evaluated in the entire cohort. RESULTS: A total of 252 patients were included. The mean age was 61.5±11.2 years, 164 (65.1%) patients were female, and TR mechanism was functional in 160 (63.5%) patients. The observed in-hospital mortality was 10.3%. The estimated mortality by the Log-ES, ES-II and TRI-SCORE was 8.7±7.3%, 4.7±5.3% and 11.0±16.6%, respectively. Patients with a TRI-SCORE ≤4 and >4 had an in-hospital mortality of 1.3% and 25.0%, p=0.001, respectively. The discriminatory capacity of the TRI-SCORE had a C-statistic of 0.87 (0.81-0.92), which was significantly higher than both the Log-ES (0.65 (0.54-0.75)) and ES-II (0.67 (0.58-0.79)), p=0.001 (for both comparisons). CONCLUSION: This external validation of the TRI-SCORE demonstrated good performance to predict in-hospital mortality in patients undergoing ITVS, which was significantly better than the Log-ES and ES-II, which underestimated the observed mortality. These results support the widespread use of this score as a clinical tool.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Adulto , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Volumen Sistólico , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento , Función Ventricular Izquierda , Factores de Riesgo , Estudios Retrospectivos
19.
J Clin Med ; 12(23)2023 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-38068420

RESUMEN

In current clinical practice, commissural alignment of the transcatheter heart valve (THV) during transcatheter aortic valve implantation (TAVI) is seldom achieved. Orientation of the THV within the aortic root and the subsequent influence upon leaflet haemodynamic function, coronary blood flow, and ease of access to the coronary ostia are gaining significant interest. Herein, we review the incidence and clinical implications of commissural misalignment in TAVI and offer thorough descriptions of how optimal alignment can be achieved with several different contemporary THV devices.

20.
JACC Cardiovasc Interv ; 16(17): 2153-2164, 2023 09 11.
Artículo en Inglés | MEDLINE | ID: mdl-37704301

RESUMEN

BACKGROUND: In patients undergoing percutaneous coronary intervention (PCI) in the work-up pre-transcatheter aortic valve replacement (TAVR), the incidence and clinical impact of late bleeding events (LBEs) remain largely unknown. OBJECTIVES: This study sought to determine the incidence, clinical characteristics, associated factors, and outcomes of LBEs in patients undergoing PCI in the work-up pre-TAVR. METHODS: This was a multicenter study including 1,457 consecutive patients (mean age 81 ± 7 years; 41.5% women) who underwent TAVR and survived beyond 30 days. LBEs (>30 days post-TAVR) were defined according to the Valve Academic Research Consortium-2 criteria. RESULTS: LBEs occurred in 116 (7.9%) patients after a median follow-up of 23 (IQR: 12-40) months. Late bleeding was minor, major, and life-threatening or disabling in 21 (18.1%), 63 (54.3%), and 32 (27.6%) patients, respectively. Periprocedural (<30 days post-TAVR) major bleeding and the combination of antiplatelet and anticoagulation therapy at discharge were independent factors associated with LBEs (P ≤ 0.02 for all). LBEs conveyed an increased mortality risk at 4-year follow-up compared with no bleeding (43.9% vs 36.0; P = 0.034). Also, LBE was identified as an independent predictor of all-cause mortality after TAVR (HR: 1.39; 95% CI: 1.05-1.83; P = 0.020). CONCLUSIONS: In TAVR candidates with concomitant significant coronary artery disease requiring percutaneous treatment, LBEs after TAVR were frequent and associated with increased mortality. Combining antiplatelet and anticoagulation regimens and the occurrence of periprocedural bleeding determined an increased risk of LBEs. Preventive strategies should be pursued for preventing late bleeding after TAVR, and further studies are needed to provide more solid evidence on the most safe and effective antithrombotic regimen post-TAVR in this challenging group of patients.


Asunto(s)
Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Intervención Coronaria Percutánea/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Hemorragia/inducido químicamente , Catéteres
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA