Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 44(46): 4862-4873, 2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-37930776

RESUMEN

BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8 mL, P < .001) and cardiac output (0.6 ± 1.2 L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2 m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Masculino , Insuficiencia de la Válvula Tricúspide/epidemiología , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Índice de Severidad de la Enfermedad
2.
Cardiovasc Ultrasound ; 19(1): 9, 2021 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-33472662

RESUMEN

PURPOSE: This study was a quality-control study of resting and exercise Doppler echocardiography (EDE) variables measured by 19 echocardiography laboratories with proven experience participating in the RIGHT Heart International NETwork. METHODS: All participating investigators reported the requested variables from ten randomly selected exercise stress tests. Intraclass correlation coefficients (ICC) were calculated to evaluate the inter-observer agreement with the core laboratory. Inter-observer variability of resting and peak exercise tricuspid regurgitation velocity (TRV), right ventricular outflow tract acceleration time (RVOT Act), tricuspid annular plane systolic excursion (TAPSE), tissue Doppler tricuspid lateral annular systolic velocity (S'), right ventricular fractional area change (RV FAC), left ventricular outflow tract velocity time integral (LVOT VTI), mitral inflow pulsed wave Doppler velocity (E), diastolic mitral annular velocity by TDI (e') and left ventricular ejection fraction (LVEF) were measured. RESULTS: The accuracy of 19 investigators for all variables ranged from 99.7 to 100%. ICC was > 0.90 for all observers. Inter-observer variability for resting and exercise variables was for TRV = 3.8 to 2.4%, E = 5.7 to 8.3%, e' = 6 to 6.5%, RVOT Act = 9.7 to 12, LVOT VTI = 7.4 to 9.6%, S' = 2.9 to 2.9% and TAPSE = 5.3 to 8%. Moderate inter-observer variability was found for resting and peak exercise RV FAC (15 to 16%). LVEF revealed lower resting and peak exercise variability of 7.6 and 9%. CONCLUSIONS: When performed in expert centers EDE is a reproducible tool for the assessment of the right heart and the pulmonary circulation.


Asunto(s)
Ecocardiografía Doppler/normas , Ventrículos Cardíacos/diagnóstico por imagen , Circulación Pulmonar/fisiología , Volumen Sistólico/fisiología , Disfunción Ventricular Derecha/diagnóstico , Función Ventricular Derecha/fisiología , Anciano , Prueba de Esfuerzo , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Curva ROC , Sístole , Disfunción Ventricular Derecha/fisiopatología , Función Ventricular Izquierda/fisiología
3.
Heart Fail Clin ; 17(3): 447-462, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34051976

RESUMEN

Heart failure with preserved ejection fraction (HFpEF) burden is increasing. Its diagnostic process is challenging and imprecise due to absence of a single diagnostic marker, and the multiparametric echocardiography evaluation needed. Left ventricular (LV) ejection fraction (LVEF) is a limited marker of LV function; thus, allocating HF phenotypes based on LVEF can be misleading. HFpEF encompasses a broad spectrum of causes, and its diagnostic criteria give a central role to echocardiography, a first-line technique with inherent limitations related to ultrasound capabilities. Conversely, cardiac magnetic resonance provides superior anatomic and functional assessment, enabling tissue characterization, offering unprecedented diagnostic precision.


Asunto(s)
Insuficiencia Cardíaca/diagnóstico , Ventrículos Cardíacos/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología , Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos/fisiopatología , Humanos
4.
Circulation ; 137(24): 2557-2567, 2018 06 12.
Artículo en Inglés | MEDLINE | ID: mdl-29530883

RESUMEN

BACKGROUND: Comparative echocardiographic data on transcatheter aortic valve replacement systems from randomized trials are limited. The REPRISE III trial (Repositionable Percutaneous Replacement of Stenotic Aortic Valve through Implantation of Lotus Valve System - Randomized Clinical Evaluation) is a multicenter, randomized comparison of a mechanically expanded (Lotus) versus self-expanding (CoreValve) transcatheter aortic valve replacement device. This analysis rigorously assesses Doppler-derived valve hemodynamics and the impact on outcomes at 1 year in patients with extreme/high surgical risk treated with Lotus and CoreValve from REPRISE III. METHODS: REPRISE III includes patients with extreme- and high-risk aortic stenosis. Patients were enrolled at 55 centers. All transthoracic echocardiograms with Doppler were obtained following a standard protocol up to 12 months postimplant and analyzed by a core laboratory. Valve size, mean gradient, aortic valve area, and Doppler velocity index and their impact on clinical outcomes are reported. Additional parameters including paravalvular leak were evaluated using a multiparametric approach. RESULTS: A total of 912 patients were randomly assigned (2:1 ratio; 607 Lotus:305 CoreValve). Median age was 84 years, 51% of the patients were women, and the Society of Thoracic Surgeons score was 6.8±4.1. CoreValve demonstrated lower gradients and larger aortic valve area and Doppler velocity index than Lotus at discharge; the difference decreased in subsequent follow-up up to a year (all P<0.01). Lotus had lower rates of paravalvular leak that persisted over time (P<0.05). Similar outcomes were seen when comparing each valve type by size group (small, medium, large). The hemodynamic differences between valves did not translate into worse clinical outcomes. All-cause mortality was not different between the 2 groups in any of the 3 valve sizes. When comparing patients with normal valve gradients (<20 mm Hg, n=780) with those with abnormal gradients (>20 mm Hg, n=48) in the entire patient population, all-cause mortality was not different. This was also not significant when evaluating each valve type separately. Similarly, there were no differences for aortic valve area >1.1 cm2 or <1.1 cm2 and for Doppler velocity index >0.35 or <0.35 (all P=not significant). CONCLUSIONS: Lotus had significantly greater freedom from moderate or severe paravalvular leak and smaller valve area and higher gradients than CoreValve. The hemodynamic differences were not associated with any clinical differences in the composite end point of mortality, disabling stroke, and moderate paravalvular leak or with quality of life at 1 year of follow-up. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02202434.


Asunto(s)
Estenosis de la Válvula Aórtica , Ecocardiografía , Hemodinámica , Calidad de Vida , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/terapia , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos
5.
Curr Cardiol Rep ; 21(4): 22, 2019 03 04.
Artículo en Inglés | MEDLINE | ID: mdl-30828743

RESUMEN

PURPOSE OF REVIEW: Pulmonary arterial hypertension (PAH) is a devastating disease which can result in right heart (RH) failure and death. Herein, we discuss the current clinical applications of echocardiography in PAH. RECENT FINDINGS: Advanced echocardiographic techniques (strain, strain rate, 2D-speckle tracking strain, and three-dimensional echocardiography) may reveal in the near future additional important insights into RH structure and function. Although right-heart catheterization is mandatory for a definitive diagnosis, echocardiography (resting and exercise) represents a key noninvasive imaging test on the diagnostic-prognostic-therapeutic PAH algorithm.


Asunto(s)
Ecocardiografía Tridimensional , Ecocardiografía , Hipertensión Arterial Pulmonar , Humanos , Hipertensión Arterial Pulmonar/diagnóstico por imagen , Función Ventricular Derecha
6.
N Engl J Med ; 382(2): 191-193, 2020 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-31733179
7.
Catheter Cardiovasc Interv ; 90(3): 526-529, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28295972

RESUMEN

Transcatheter aortic valve replacement is standard of care for patients with severe aortic stenosis at high risk for surgical aortic valve replacement. Although not intended for treatment of primary aortic insufficiency, several transcatheter aortic valve prostheses have been used to treat patients with severe aortic insufficiency (AI), including patients with left ventricular assist devices (LVAD), in whom significant AI is not uncommon. Similarly, transcatheter valve replacements have been used for valve-in-valve treatment, in the pulmonary, aortic, and mitral positions, either via a retrograde femoral approach or antegrade transseptal approach (mitral valve-in-valve). In this case report, we report an LVAD patient with severe aortic insufficiency and severe bioprosthetic mitral prosthetic stenosis, in whom we successfully performed transfemoral aortic valve replacement and transfemoral mitral valve-in-valve replacement via a transseptal approach. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/instrumentación , Insuficiencia Cardíaca/terapia , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Corazón Auxiliar , Estenosis de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Función Ventricular Izquierda , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/métodos , Ecocardiografía Doppler en Color , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Estenosis de la Válvula Mitral/diagnóstico , Estenosis de la Válvula Mitral/fisiopatología , Diseño de Prótesis , Falla de Prótesis , Recuperación de la Función , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
8.
Echocardiography ; 33(1): 57-65, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26096076

RESUMEN

AIMS: To elucidate right ventricular (RV) function in patients with idiopathic pulmonary fibrosis (IPF) with and without pulmonary hypertension (PH) and its relation to other features of the disease. METHODS AND RESULTS: Clinical evaluation, standard Doppler echo, Doppler myocardial imaging (DMI), and 2D strain echocardiography (STE) of RV septal and lateral walls were performed in 52 IPF patients (66.5 ± 8.5 years; 27 males) and in 45 age- and sex-comparable controls using a commercial US system (MyLab Alpha, Esaote). Pulmonary artery mean pressure (mPAP) was estimated by standard echo Doppler. RV global longitudinal strain (RV GLS) was calculated by averaging RV local strains. The IPF patients were divided into 2 groups by noninvasive assessment of PH: no PH (mPAP<25 mmHg; 36 pts) and PH (mPAP ≥25 mmHg; 16 pts). Left ventricular diameters and ejection fraction were comparable between controls and IPF, while GLS was impaired in IPF (P < 0.01). RV end-diastolic diameters, wall thickness andmPAP were increased in IPF patients with PH. In addition, pulsed DMI detected in PH IPF impaired myocardial RV early diastolic (Em) peak velocity. Also peak systolic RV strain was reduced in basal and middle RV lateral free walls in IPF, as well as RV GLS (P < 0.0001). The impairment in RV wall strain was more evident when comparing controls with the no PH group than comparing the no PH group with the PH group. By multivariate analysis, independent association of RV strain with both six-minute walking test distance (P < 0.001), mPAP (P < 0.0001), as well as with forced vital capacity (FVC) % (P < 0.005) in IPF patients were observed. CONCLUSIONS: Impaired RV diastolic and systolic myocardial function were present even in IPF patients without PH, which indicates an early impact on RV function and structure in patients with IPF.


Asunto(s)
Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Hipertensión Pulmonar/diagnóstico por imagen , Hipertensión Pulmonar/fisiopatología , Fibrosis Pulmonar Idiopática/diagnóstico por imagen , Fibrosis Pulmonar Idiopática/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Ecocardiografía Doppler , Femenino , Humanos , Hipertensión Pulmonar/complicaciones , Fibrosis Pulmonar Idiopática/complicaciones , Masculino , Persona de Mediana Edad
11.
Front Cardiovasc Med ; 11: 1366444, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38601046

RESUMEN

Background: Mitral annular disjunction (MAD) refers to the arrhythmic mitral valve prolapse (MVP) syndrome associated with ventricular arrhythmias and sudden cardiac death. Although the pathophysiology of this disease is still under investigation, specific imaging criteria that establish the diagnosis have been recognized. In this article, we demonstrate most of these criteria using three-dimensional transthoracic echocardiography (3D-TTE) and provide added value in the management of MAD syndrome. Case presentation: A 50-year-old male patient with recent syncope and a history of mitral regurgitation (MR) and MAD was admitted to our clinic for further investigation. According to our protocol, the patient underwent a complete 3D-TTE, laboratory blood exams, and 24 h ambulatory electrocardiogram (ECG). Our investigation confirmed the presence of MAD syndrome with bileaflet prolapse, severe MR, and non-sustained ventricular tachycardia, necessitating an implantable cardioverter defibrillator (ICD) and surgical mitral valve repair. The 3D-TTE analysis of the mitral valve demonstrated mitral annular systolic expansion and systolic flattening of the saddle-shaped annulus and quantified the extent of the disjunction arc. Additionally, four-dimensional (4D) strain analysis of the left ventricle revealed the presence of fibrosis of the posteromedial papillary muscle and basal inferolateral wall, which are variables that are required for the diagnosis and therapeutic management of MAD syndrome. Conclusions: 3D-TTE and 4D strain offer valuable insights for diagnosing and managing patients with MAD syndrome. This method seems to correlate well with the other imaging modalities and could be included in the management protocol of MAD syndrome.

12.
Am J Cardiol ; 213: 99-105, 2024 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-38110022

RESUMEN

The association, if any, between the effective regurgitant orifice area (EROA) to left ventricular end-diastolic volume (LVEDV) ratio and 1-year mortality is controversial in patients who undergo mitral transcatheter edge-to-edge repair (m-TEER) with the MitraClip system (Abbott Vascular, Santa Clara, CA). This study's objective was to determine the association between EROA/LVEDV and 1-year mortality in patients who undergo m-TEER with MitraClip. In patients with severe secondary (functional) mitral regurgitation (MR), we analyzed registry data from 11 centers using generalized linear models with the generalized estimating equations approach. We studied 525 patients with secondary MR who underwent m-TEER. Most patients were male (63%) and were New York Heart Association class III (61%) or IV (21%). Mitral regurgitation was caused by ischemic cardiomyopathy in 51% of patients. EROA/LVEDV values varied widely, with median = 0.19 mm2/ml, interquartile range [0.12,0.28] mm2/ml, and 187 patients (36%) had values <0.15 mm2/ml. Postprocedural mitral regurgitation severity was substantially alleviated, being 1+ or less in 74%, 2+ in 20%, 3+ in 4%, and 4+ in 2%; 1-year mortality was 22%. After adjustment for confounders, the logarithmic transformation (Ln) of EROA/LVEDV was associated with 1-year mortality (odds ratio 0.600, 95% confidence interval 0.386 to 0.933, p = 0.023). A higher Society of Thoracic Surgeons risk score was also associated with increased mortality. In conclusion, lower values of Ln(EROA/LVEDV) were associated with increased 1-year mortality in this multicenter registry. The slope of the association is steep at low values but gradually flattens as Ln(EROA/LVEDV) increases.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Masculino , Femenino , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Resultado del Tratamiento , Sistema de Registros , América del Norte
13.
Artículo en Inglés | MEDLINE | ID: mdl-38970594

RESUMEN

3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.

14.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38099912

RESUMEN

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Valor Predictivo de las Pruebas , Recuperación de la Función , Índice de Severidad de la Enfermedad , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Masculino , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Resultado del Tratamiento , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Anciano , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Factores de Tiempo , Anciano de 80 o más Años , Prótesis Valvulares Cardíacas , Estudios de Factibilidad , Medición de Riesgo , Diseño de Prótesis , Ecocardiografía Tridimensional
15.
JACC Clin Electrophysiol ; 9(1): 111-116, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36697189

RESUMEN

Percutaneous left atrial appendage occlusion (LAAO) is contraindicated in presence of left atrial appendage (LAA) thrombus. It is often difficult to separate LAA sludge from an organized thrombus on transesophageal echocardiography. The inability to differentiate sludge from thrombus leads to patients not receiving LAAO despite contraindication to long-term anticoagulation. Retrospective 6-month follow-up outcomes are reported on patients undergoing LAAO in presence of LAA sludge cleared by isoproterenol. This study showed no increased risk of transient ischemic attack/stroke in the 6 months following LAAO in the presence of LAA sludge, which was cleared with isoproterenol. This study suggests a role for isoproterenol in differentiating sludge from thrombus.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Cardiopatías , Trombosis , Humanos , Isoproterenol/uso terapéutico , Aguas del Alcantarillado , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Estudios Retrospectivos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Trombosis/etiología , Cardiopatías/etiología
16.
Eur Heart J Cardiovasc Imaging ; 24(3): 392-400, 2023 02 17.
Artículo en Inglés | MEDLINE | ID: mdl-35348652

RESUMEN

AIMS: Several changes of the mitral valve (MV) morphology have been previously documented in ischaemic mitral regurgitation (IMR) upon macro and microscopic examination. This study aimed to correlate echocardiographic MV thickening with IMR severity and to delineate the histopathological basis of valve thickening from the explanted leaflets. METHODS AND RESULTS: Two hundred and fifty patients were included in the echo-group; of these, 48 patients (19.2%) underwent surgical mitral valve replacement (MVR), including them in the histology-group. By echocardiography, the thickness of the anterior and posterior leaflet was more extensive in moderate to severe IMR, P < 0.001. Histology-group: patients were divided into two groups based on the median thickness: those with cusp thickness <0.42 cm in Group 1, and ≥0.42 cm in Group 2. The thickness of the base and cusp was more significant in Group 2, P < 0.05 in both. Group 2 biopsies were characterized by involvement of the three leaflet segments, myxoid tissue, and fibrosis deposition. Thicker leaflets were associated with a greater degree of mitral regurgitation (MR), P < 0.0001. In the echo-group, a median leaflet thickness of 3.5 mm of the anterior and posterior MV was independently associated with moderate to severe ischaemic MR [odds ratio (OR) 2.88, P < 0.01] and (OR 10.8, P < 0.001), respectively. CONCLUSION: In ischaemic MR, the thicker the cusps, the worse the MR. Leaflet thickening was due to the myxoid and fibrosis deposition and was detected by echocardiography. Therefore, this method can be helpful in the evaluation of valve remodelling.


Asunto(s)
Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Ecocardiografía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Válvula Mitral/patología , Prolapso de la Válvula Mitral/cirugía , Fibrosis
17.
J Am Coll Cardiol ; 82(8): 721-734, 2023 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-37587584

RESUMEN

Valvular heart disease (VHD) is common and poses important challenges from the standpoints of diagnosis and therapeutic management. Clinical practice guidelines have been developed to help health care professionals to overcome these challenges and provide optimal management to patients with VHD. The American College of Cardiology, in collaboration with the American Heart Association, and the European Society of Cardiology, in collaboration with the European Association for Cardio-Thoracic Surgery, recently updated their guidelines on the management of VHD. Although these 2 sets of guidelines are generally concordant, there are some substantial differences between these guidelines, which may have significant implications for clinical practice. This review prepared on behalf of the EuroValve Consortium describes the consistencies and discrepancies between the guidelines and highlights the gaps in these guidelines and the future research perspectives to fill these gaps.


Asunto(s)
Cardiología , Enfermedades de las Válvulas Cardíacas , Estados Unidos , Humanos , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/terapia , Corazón , American Heart Association , Personal de Salud
18.
Eur Heart J Cardiovasc Imaging ; 24(8): e119-e197, 2023 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-37259019

RESUMEN

Three-dimensional transoesophageal echocardiography (3D TOE) has been rapidly developed in the last 15 years. Currently, 3D TOE is particularly useful as an additional imaging modality for the cardiac echocardiographers in the echo-lab, for cardiac interventionalists as a tool to guide complex catheter-based procedures cardiac, for surgeons to plan surgical strategies, and for cardiac anaesthesiologists and/or cardiologists, to assess intra-operative results. The authors of this document believe that acquiring 3D data set should become a 'standard part' of the TOE examination. This document provides (i) a basic understanding of the physic of 3D TOE technology which enables the echocardiographer to obtain new skills necessary to acquire, manipulate, and interpret 3D data sets, (ii) a description of valvular pathologies, and (iii) a description of non-valvular pathologies in which 3D TOE has shown to be a diagnostic tool particularly valuable. This document has a new format: instead of figures randomly positioned through the text, it has been organized in tables which include figures. We believe that this arrangement makes easier the lecture by clinical cardiologists and practising echocardiographers.


Asunto(s)
Cardiología , Sistema Cardiovascular , Ecocardiografía Tridimensional , Humanos , Ecocardiografía Transesofágica/métodos , Ecocardiografía Tridimensional/métodos , Corazón
19.
J Am Coll Cardiol ; 82(21): 1973-1985, 2023 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-37968015

RESUMEN

BACKGROUND: Exercise echocardiography is used for assessment of pulmonary circulation and right ventricular function, but limits of normal and disease-specific changes remain insufficiently established. OBJECTIVES: The objective of this study was to explore the physiological vs pathologic response of the right ventricle and pulmonary circulation to exercise. METHODS: A total of 2,228 subjects were enrolled: 375 healthy controls, 40 athletes, 516 patients with cardiovascular risk factors, 17 with pulmonary arterial hypertension, 872 with connective tissue diseases without overt pulmonary hypertension, 113 with left-sided heart disease, 30 with lung disease, and 265 with chronic exposure to high altitude. All subjects underwent resting and exercise echocardiography on a semirecumbent cycle ergometer. All-cause mortality was recorded at follow-up. RESULTS: The 5th and 95th percentile of the mean pulmonary artery pressure-cardiac output relationships were 0.2 to 3.5 mm Hg.min/L in healthy subjects without cardiovascular risk factors, and were increased in all patient categories and in high altitude residents. The 5th and 95th percentile of the tricuspid annular plane systolic excursion to systolic pulmonary artery pressure ratio at rest were 0.7 to 2.0 mm/mm Hg at rest and 0.5 to 1.5 mm/mm Hg at peak exercise, and were decreased at rest and exercise in all disease categories and in high-altitude residents. An increased all-cause mortality was predicted by a resting tricuspid annular plane systolic excursion to systolic pulmonary artery pressure <0.7 mm/mm Hg and mean pulmonary artery pressure-cardiac output >5 mm Hg.min/L. CONCLUSIONS: Exercise echocardiography of the pulmonary circulation and the right ventricle discloses prognostically relevant differences between healthy subjects, athletes, high-altitude residents, and patients with various cardio-respiratory conditions. (Right Heart International NETwork During Exercise in Different Clinical Conditions; NCT03041337).


Asunto(s)
Hipertensión Pulmonar , Disfunción Ventricular Derecha , Humanos , Ecocardiografía de Estrés/efectos adversos , Circulación Pulmonar , Prueba de Esfuerzo/efectos adversos , Ventrículos Cardíacos/diagnóstico por imagen , Función Ventricular Derecha/fisiología , Disfunción Ventricular Derecha/diagnóstico por imagen
20.
Circ J ; 76(11): 2640-6, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22878352

RESUMEN

BACKGROUND: The current study was designed to investigate the correlation between the left ventricular (LV) vortex flow pattern and LV apical thrombus formation in patients with acute anterior wall myocardial infarction (MI). METHODS AND RESULTS: Fifty-seven patients with acute anterior wall MI were enrolled in this study. Eighteen patients with apical thrombus (thrombus group) and 39 patients without apical thrombus (non-thrombus group) underwent 2-dimensional contrast echocardiography (CE). Morphology and pulsatility parameters of the LV vortex were measured using Omega flow(®) and compared between the 2 groups. In the thrombus group, the vortex was located more centrally and did not extend to the apex. In the thrombus group, quantitative vortex parameters of vortex depth (0.409±0.101 vs. 0.505±0.092, respectively; P=0.002) and relative strength (1.574±0.310 vs. 1.808±0.376, respectively, P=0.034) were significantly lower than the non-thrombus group. Following multivariate analysis, the vortex depth below 0.45 remained a significant independent parameter for formation of the LV apical thrombus (odds ratio 9.714, 95% confidence interval 1.674-56.381, P=0.011). CONCLUSIONS: These findings suggest that the location and pulsatility power of the LV vortex are strongly associated with the LV thrombus formation in patients with anterior MI. Therefore, LV vortex flow analysis using CE can be clinically useful for characterizing and quantifying the risk of LV apical thrombus in patients with anterior MI.


Asunto(s)
Infarto de la Pared Anterior del Miocardio , Ecocardiografía , Ventrículos Cardíacos , Trombosis , Anciano , Infarto de la Pared Anterior del Miocardio/diagnóstico por imagen , Infarto de la Pared Anterior del Miocardio/fisiopatología , Velocidad del Flujo Sanguíneo , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Flujo Pulsátil , Trombosis/diagnóstico por imagen , Trombosis/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA