Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Rev Cardiovasc Med ; 24(2): 62, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-39077421

RESUMEN

Background: Recently, questions around the efficacy and effectiveness of Fractional Flow Reserve (FFR) have arisen in various clinical settings. Methods: The Clinical Outcome of FFR-guided Revascularization Strategy of Coronary Lesions (HALE-BOPP) study is an investigator-initiated, multicentre, international prospective study enrolling patients who underwent FFR measurement on at least one vessel. In accordance with the decision-making workflow and treatment, the vessels were classified in three subgroups: (i) angio-revascularized, (ii) FFR-revascularized, (iii) FFR-deferred. The primary endpoint was the occurrence of target vessel failure (TVF, cardiac death, target vessel myocardial infarction and ischemia-driven target vessel revascularization). The analysis was carried out at vessel- and patient-level. Results: 1305 patients with 2422 diseased vessels fulfilled the criteria for the present analysis. Wire-related pitfalls and transient adenosine-related side effects occurred in 0.8% (95% CI: 0.4%-1.4%) and 3.3% (95% CI: 2.5%-4.3%) of cases, respectively. In FFR-deferred vessels, the overall incidence rate of TVF was 0.024 (95% CI: 0.019-0.031) lesion/year. After a median follow-up of 3.6 years, the occurrence of TVF was 6%, 7% and 11.7% in FFR-deferred, FFR-revascularized and angio-revascularized vessels, respectively. Compared to angio-revascularized vessels, FFR-guided vessels (both FFR-revascularized and FFR-deferred vessels) showed a lower TVF incidence rate lesion/year (0.029, 95% CI: 0.024-0.034 vs. 0.049, 95% CI: 0.040-0.061 respectively, p = 0.0001). The result was consistent after correction for confounding factors and across subgroups of clinical interest. The patient-level analysis confirmed the lower occurrence of TVF in negative-FFR vs. positive-FFR subgroups. Conclusions: In a large prospective observational study, an FFR-based strategy for the deferral of coronary lesions is a reliable and safe tool, associated with good outcomes. Clinical Trial Registration: NCT03079739.

2.
J Endovasc Ther ; : 15266028231217657, 2023 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-38084379

RESUMEN

PURPOSE: The aim of this study was to assess the efficacy and safety of the novel SLR (SELUTION sustained-limus-release) drug-coated balloon (DCB) in the treatment of the femoropopliteal steno-occlusive disease. MATERIALS AND METHODS: From February 2021 to March 2022, 80 consecutive patients (age: 69.5±8.23 years; total number of lesions: 80) with a steno-occlusive lesion of superficial femoral artery were enrolled at our center. A total of 60 patients (75%) had claudication, whereas 20 (25%) had chronic limb-threatening ischemia (CLTI). The mean lesion length was 171±82.22 mm. The primary efficacy outcome was primary patency at 12 months, defined as freedom from restenosis determined by a duplex ultrasound peak systolic velocity ratio ≤2.4. The secondary efficacy outcome was freedom from clinically-driven target lesion revascularization (CD-TLR) at 12 months. The primary safety outcome was a composite of freedom from device- and procedure-related mortality, major target limb amputation, and clinically-driven target lesion urgent revascularization (endovascular or bypass graft) at 30 days and 12 months. RESULTS: Device success was achieved in all 80 patients. One death on day 7 from cardiovascular complications was ruled procedure-related because it occurred within the first 30 days from the discharge. Two patients with CLTI experienced planned minor amputations of target limb, and one patient underwent urgent bypass graft of the target vessel for early occlusion at 60 days from the index procedure. The primary safety outcome was 98.7% and 97.5% at 30 days and 12 months, respectively. At 1 year, primary patency was 86.3%, and freedom from CD-TLR was 96.2%. CONCLUSION: These findings suggest that using a novel sirolimus-coated balloon is a safe and effective treatment option for femoropopliteal steno-occlusive lesions in a variety of clinical and anatomical settings. These results will need to be confirmed by long-term follow-up and randomized controlled trials. CLINICAL IMPACT: In femoropopliteal steno-occlusive lesions paclitaxel drug-coated devices have been proved to be able to achieve a better vessel patency during follow-up compared with uncoated balloon, but according to a recent meta-analysis they may carry an elevated risk of late mortality. Sirolimus results in a wider therapeutic range with a 3-fold higher margin of safety. Sirolimus coated devices have recently been proposed as an alternative. This study suggests that using a novel sirolimus-coated balloon is a safe and effective treatment option for femoropopliteal steno-occlusive lesions.

3.
Echocardiography ; 40(8): 768-774, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37342979

RESUMEN

BACKGROUND: Aortic valve stenosis (AS) is the most common valvular heart disease worldwide. When timely intervention is performed, aortic valve replacement can improve patients' quality and duration of life. Load-independent left ventricular (LV) functional assessments, such as myocardial work indices (MWIs) and LV diastolic function parameters, could help clinicians decide on the optimal timing of intervention. AIMS: To evaluate the reliability of MWI in AS patients and the changes in MWI and LV diastolic function after transcatheter aortic valve replacement (TAVR). METHODS: We enrolled 53 consecutive patients with severe AS undergoing TAVR admitted between March 2021 and November 2021. MWIs and LV diastolic function were assessed before and after TAVR for each patient. RESULTS: All MWIs and LV diastolic function indices improved after TAVR. The degree of MWIs improvement was higher in patients with lower prior-TAVR MWI values, while the more severe the impairment of diastolic function, the greater the post-TAVR benefit. CONCLUSION: The introduction of myocardial work parameters into the routine assessment of patients with AS could improve our understanding of cardiac performance and aid in identifying the optimal timing for surgical or percutaneous treatment.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reproducibilidad de los Resultados , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Función Ventricular Izquierda , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad , Estudios Retrospectivos
4.
Catheter Cardiovasc Interv ; 99(4): 1310-1316, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34779119

RESUMEN

BACKGROUND: Endarterectomy is considered the gold standard therapy for common femoral artery (CFA) steno-occlusive lesions, but a significant risk of perioperative mortality and complications has been reported. OBJECTIVE: Aim of this study is to evaluate the efficacy at a long-term follow-up of patients with CFA steno-occlusive lesions treated with directional atherectomy and drug coated balloon (DCB). MATERIAL AND METHODS: In this single-center registry, 78 patients (male: 80.7%; age: 71 ± 15 years; occlusions: 25%) with 80 CFA lesions were included, with 39.7% of them undergoing directional atherectomy and drug coated balloon due to critical limb ischemia and 60.3% due to lower-limb intermittent claudication. The long-term follow-up was completed by 75 patients (3 years). The 31 patients with critical ischemia (39.7%) were further subdivided into 20 (25.6%) patients with pain at rest and 11 (14.1%) with trophic changes, ulcers and/or tissue loss. We considered the primary and the secondary outcome, referring, respectively to peak systolic velocity ratio (PSVR) ≥ 2.4 on duplex or > 50% stenosis on digital subtraction angiography at 36 months and to clinically driven target lesion revascularization at 36 months. RESULTS: The primary and secondary outcome was obtained in 84% and 86.7% of patients, at 36 months of follow up. Bailout stenting was necessary in 6/80 cases (7.5%) for suboptimal result. Freedom from MALE was obtained in 98.6% of patients. CONCLUSIONS: These results confirm that directional atherectomy and drug coated balloon strategy for the treatment of CFA lesions is effective at a long-term follow-up and could be considered as a good alternative to surgery.


Asunto(s)
Angioplastia de Balón , Enfermedad Arterial Periférica , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/efectos adversos , Aterectomía/efectos adversos , Materiales Biocompatibles Revestidos , Arteria Femoral , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Arteria Poplítea , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
5.
Europace ; 20(1): 116-123, 2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-28339584

RESUMEN

Aims: Preliminary data on Sapien 3 valve (S3-THV) use for transcatheter aortic valve implantation have shown an increased permanent pacemaker implantation (PPMI) rate with respect to Sapien XT valve. Aim of this study was to investigate the role of S3-THV position in the left ventricular outflow tract (LVOT) on electrocardiographic changes suggestive of atrioventricular (ΔPR) and/or intraventricular (ΔQRS) conduction abnormalities and 30 days PPMI rate. Methods and results: Eighty-six consecutive patients treated with S3-THV were included in the study. All patients underwent clinical and electrocardiogram evaluation. Left ventricular outflow tract prosthesis depth was assessed by fluoroscopy and expressed quantitatively (mm) and as aorto-ventricular ratio (AVR). Eight patients (9.3%) needed PPMI at 30 days. A low AVR (≤60/40) predicted PPMI (OR = 6.09, 95% CI 1.19-31.01, P = 0.030) and resulted into higher PPMI rate, compared with higher AVR (30.0 vs. 6.6%, P = 0.017). For each millimetre increase in the LVOT prosthesis depth PPMI risk increased by 1.41 times (95% CI 1.06-1.87, P = 0.017). In patients with low AVR, ΔPR was higher than in those with higher AVR (33.4 ± 56.7 vs. 12.1 ± 19.4 ms, P = 0.021) and ΔPR was associated to LVOT prosthesis depth (ß = 0.286, P = 0.009). Furthermore, ΔPR was associated with risk of PPMI (OR = 1.03, 95% CI 1.01-1.06, P = 0.024). Conclusions: A low AVR is associated to higher ΔPR and PPMI rates. The correlation between LVOT prosthesis depth with ΔPR and higher PPMI rate suggests the need of a careful S3-THV implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/trasplante , Arritmias Cardíacas/etiología , Valvuloplastia con Balón/efectos adversos , Frecuencia Cardíaca , Prótesis Valvulares Cardíacas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial , Distribución de Chi-Cuadrado , Electrocardiografía , Femenino , Humanos , Italia , Modelos Lineales , Modelos Logísticos , Masculino , Análisis Multivariante , Oportunidad Relativa , Marcapaso Artificial , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento
6.
G Ital Cardiol (Rome) ; 25(6): 16-22, 2024 Jun.
Artículo en Italiano | MEDLINE | ID: mdl-38912743

RESUMEN

Over the last few decades, endovascular revascularization techniques have revolutionized the treatment of peripheral artery disease, offering a less invasive alternative to surgery. However, the successful treatment of heavily calcified lesions is often compromised by various vascular complications, including recoils, dissections, and the need for target vessel reinterventions. This has prompted the development of several tools for lesion preparation, with the aim of achieving better procedural outcomes. This review aims to summarize the main characteristics and current evidence related to the available devices for preparing severely calcified peripheral lesions.


Asunto(s)
Procedimientos Endovasculares , Enfermedad Arterial Periférica , Calcificación Vascular , Humanos , Procedimientos Endovasculares/métodos , Enfermedad Arterial Periférica/terapia , Enfermedad Arterial Periférica/cirugía , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/terapia , Índice de Severidad de la Enfermedad
7.
Diagnostics (Basel) ; 13(7)2023 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-37046483

RESUMEN

Carotid artery stenting (CAS) is usually performed through a femoral vascular access using 6-9 Fr guiding catheters. We investigated whether a systematic distal radial approach using 5 Fr guiding sheaths was a safe and effective alternative to transfemoral approach for CAS. From July 2020 to October 2022, two operators at our center systematically performed CAS using a 5 Fr distal radial approach in consecutive patients. The main endpoints of the study were procedural success via distal radial and via proximal or distal radial access. The learning curve was evaluated by comparing the first half of patients versus the second half of patients enrolled. Procedural data and 30-day clinical outcomes were collected. Fifty-one patients were prospectively enrolled. CAS was effectively performed via distal radial access in 45 patients (88%). Overall radial artery success was 92%. Distal radial CAS was successfully performed in 20 out of the first 25 patients enrolled (80%), and in 25 of the last 26 patients enrolled (96%; p = 0.07). Significantly less contrast was administered in the last 26 patients compared to the first 25 enrolled (110 (70, 140) mL vs. 120 (107, 150) mL; p = 0.045). Radial artery occlusion was reported in 1 patient (2%). Only 1 minor stroke (2%) was reported in-hospital and at 30-day follow-up. In conclusion, distal radial CAS using 5 Fr catheters was a safe procedure with a high success rate. The procedure had a relatively short learning curve in operators familiar with transfemoral CAS.

8.
Minerva Cardiol Angiol ; 71(5): 599-605, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36475548

RESUMEN

BACKGROUND: The primary patency rate of superficial femoral artery (SFA) after percutaneous transluminal angioplasty (PTA) has improved with the use of self-expanding stents. However, occurrence of in-stent restenosis (ISR) still represents a frequent problem. Despite different studies have assessed the role of atherectomy and drug coated balloons (DCBs), no long-term data exist about combined use. The aim of this study was to evaluate safety and efficacy of combined treatment with Jetstream (Boston Scientific Corp., Marlborough, MA, USA) atherectomy and DCB for SFA intrastent restenosis (ISR) at 2-year follow-up. METHODS: 30 patients treated with PTA from November 2018 to September 2019 at Montevergine Clinic (Mercogliano, Avellino, Italy) were included in this analysis. All patients underwent PTA of SFA-ISR with Jetstream Atherectomy System followed by paclitaxel eluting balloon treatment. Patients were evaluated at 30 days, and every 3 months up to 24. RESULTS: Technical and procedural success was achieved in every patient. No in-hospital major adverse cardiac and cerebrovascular events occurred. No acute and sub-acute(in-hospital) procedure related complications occurred. During follow-up, 1 patient died due to stroke. Primary patency rate at 12 months was 93.4%. Primary patency rate at 24 months was 83.4%. Secondary patency rate at 24 months was 96.7%. One minor amputation, planned before treatment, was performed in the first 30 days. CONCLUSIONS: Our data suggest that combined therapy with Rotational Atherectomy and DCBs for SFA-ISR represents a safe and effective procedure with a high rate of primary patency at 2-year follow-up.


Asunto(s)
Angioplastia de Balón , Aterectomía Coronaria , Reestenosis Coronaria , Enfermedad Arterial Periférica , Humanos , Arteria Femoral/cirugía , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/métodos , Reestenosis Coronaria/etiología , Resultado del Tratamiento , Enfermedad Arterial Periférica/terapia
11.
J Cardiovasc Med (Hagerstown) ; 7(8): 608-13, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16858240

RESUMEN

OBJECTIVE: Our knowledge about the natural history of peripheral arterial disease (PAD) is derived from studies carried out almost exclusively in northern European and northern American populations. This study was aimed at defining mortality and cardiovascular morbidity of PAD patients in Italy. METHODS: From the lists of seven general practitioners, we identified all subjects aged 40-80 years (n = 4352). Of those reporting leg symptoms while walking at the Rose Questionnaire (n = 760), 60 (1.6% of the general population) had PAD, as evidenced by an ankle-brachial index of < 0.90 or reduced Doppler flow velocity. For each PAD patient, three sex and age-matched controls negative to the Rose Questionnaire were randomly selected from the general practice lists. RESULTS: After 24 months of follow-up, 15% of PAD patients died, 8% from cardiovascular disease, and 25% developed a non-fatal cardiovascular event. At Cox analysis, the presence of PAD was associated with an increased risk of all-cause mortality (relative risk 4.03; 95% confidence interval 1.50-10.84; P = 0.006), cardiovascular mortality (relative risk 7.77; 95% confidence interval 1.51-40.16; P = 0.014), and non-fatal cardiovascular events (relative risk 3.11; 95% confidence interval 1.41-6.80; P = 0.005). CONCLUSIONS: This Italian study shows that, in general practice, symptomatic PAD is associated with a four-fold increased risk of mortality and a nearly eight-fold increased risk of cardiovascular mortality. These figures are quite similar to those reported in northern European and northern American populations. General practitioners, who are the clinicians primarily and largely responsible for the care of these patients, should be alerted to the consequences of PAD.


Asunto(s)
Enfermedades Cardiovasculares/etiología , Enfermedades Vasculares Periféricas/complicaciones , Adulto , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Enfermedades Cardiovasculares/mortalidad , Causas de Muerte , Femenino , Estudios de Seguimiento , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Enfermedades Vasculares Periféricas/diagnóstico por imagen , Enfermedades Vasculares Periféricas/epidemiología , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Factores de Riesgo , Encuestas y Cuestionarios , Ultrasonografía Doppler
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA