Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
2.
Curr Cardiol Rep ; 22(8): 74, 2020 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-32594261

RESUMEN

PURPOSE OF REVIEW: This review article describes the technical features of the novel Edwards PASCAL transcatheter valve repair system as well as the evidence accumulated so far. RECENT FINDINGS: Transcatheter mitral and tricuspid valve leaflet approximation enable treatment of patients with mitral and tricuspid regurgitation who are not eligible for surgery. The PASCAL device offers an alternative that may allow to overcome some of the limitations of previous systems and open the path for an approach adapted to individual patient's anatomy. Early data show similar safety and efficacy compared with the Abbott MitraClip system. The PASCAL system is a valuable addition to the armamentarium of transcatheter mitral and tricuspid valve repair devices. Randomized head-to-head comparisons and long-term data are needed to confirm the promising results observed so far.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Insuficiencia de la Válvula Tricúspide , Cateterismo Cardíaco , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía
3.
Front Cardiovasc Med ; 7: 61, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32500083

RESUMEN

Valvular heart disease is responsible for a high rate of morbidity and mortality, especially in the elderly population. With the emergence of new transcatheter treatment options, the therapeutic spectrum for patients with valvular heart disease has considerably expanded during the past years. Interventional treatment of the mitral and tricuspid valve requires an individualized and versatile approach owing to the different etiologies of valvular dysfunction and the complex anatomy of the atrioventricular valves. This article aims to review recent developments, summarize the evidence, indications and limitations of the available systems, and provide a glimpse into the future of transcatheter interventions for the treatment of mitral and tricuspid valve disease.

4.
Front Cardiovasc Med ; 6: 179, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31921895

RESUMEN

Degenerative heart valve disease is associated with significant morbidity and mortality and healthcare expenditures. Transcatheter heart valve repair and replacement has introduced a fundamental change in the therapeutic management and transcatheter aortic valve replacement (TAVR) has gained substantial popularity. Favorable results from randomized trials and large real world registries lead to TAVR being considered a standard procedure with high rates of procedural success and low rates of peri-procedural complications. This article aims to review the past evolution, summarize the available evidence, discuss current indications and limitations and venture a glimpse into the future of percutaneous interventions for aortic valve disease.

5.
JACC Cardiovasc Interv ; 12(21): 2173-2182, 2019 11 11.
Artículo en Inglés | MEDLINE | ID: mdl-31564593

RESUMEN

OBJECTIVES: This study sought to compare the frequency of prosthesis-patient mismatch (PPM) with self-expandable valves (SEV) to balloon-expandable valves (BEV). BACKGROUND: PPM has been associated with increased mortality after transcatheter aortic valve replacement. Data on the frequency of PPM as a function of supra-annular or intra-annular position of transcatheter heart valves are insufficient. METHODS: A total of 757 patients treated with SEV (CoreValve, Evolut R) and BEV (SAPIEN THV/XT/3) were enrolled in the present analysis between August 2007 and June 2017. PPM was classified based on discharge prosthetic effective orifice area indexed to body surface area (BSA) as severe (<0.65 cm2/m2) or moderate (0.65 to 0.85 cm2/m2) in the general population, and as severe (<0.60 cm2/m2) or moderate (0.60 to 0.90 cm2/m2) in the obese population (body mass index ≥30 kg/m2). RESULTS: Propensity score matching resulted in 224 matched pairs. At discharge, SEV were associated with a lower incidence of PPM compared with BEV (PPM, 33.5% vs. 46.9%; p = 0.004; severe PPM, 6.7% vs. 15.6%; p = 0.003). The lower frequency of severe PPM in SEV was observed even in patients with larger annulus. Although patients with BSA >1.83 m2 had a significantly lower incidence of PPM with SEV compared with BEV, there was no significant difference in patients with BSA ≤1.83 m2. We found no impact of PPM on cardiovascular mortality or New York Heart Association functional class at 1 year. CONCLUSIONS: SEV were associated with a lower frequency of PPM compared with BEV irrespective of annulus area. The difference was mainly driven by larger patients with BSA >1.83 m2.


Asunto(s)
Válvula Aórtica/cirugía , Valvuloplastia con Balón , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Hemodinámica , Humanos , Masculino , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Suiza , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA