Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38849662

RESUMEN

Ovarian masses encompass various conditions, from benign to highly malignant, and imaging plays a vital role in their diagnosis and management. Ultrasound, particularly transvaginal ultrasound, is the foremost diagnostic method for adnexal masses. Magnetic Resonance Imaging (MRI) is advised for more precise characterisation if ultrasound results are inconclusive. The ovarian-adnexal reporting and data system (O-RADS) MRI lexicon and scoring system provides a standardised method for describing, assessing, and categorising the risk of each ovarian mass. Determining a histological differential diagnosis of the mass may influence treatment decision-making and treatment planning. When ultrasound or MRI suggests the possibility of cancer, computed tomography (CT) is the preferred imaging technique for staging. It is essential to outline the extent of the malignancy, guide treatment decisions, and evaluate the feasibility of cytoreductive surgery. This article provides a comprehensive overview of the key imaging processes in evaluating and managing ovarian masses, from initial diagnosis to initial treatment. It also includes pertinent recommendations for properly performing and interpreting various imaging modalities. KEY POINTS: MRI is the modality of choice for indeterminate ovarian masses at ultrasound, and the O-RADS MRI lexicon and score enable unequivocal communication with clinicians. CT is the recommended modality for suspected ovarian masses to tailor treatment and surgery. Multidisciplinary meetings integrate information and help decide the most appropriate treatment for each patient.

2.
Eur Radiol ; 2024 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-38206405

RESUMEN

OBJECTIVES: To assess radiologists' current use of, and opinions on, structured reporting (SR) in oncologic imaging, and to provide recommendations for a structured report template. MATERIALS AND METHODS: An online survey with 28 questions was sent to European Society of Oncologic Imaging (ESOI) members. The questionnaire had four main parts: (1) participant information, e.g., country, workplace, experience, and current SR use; (2) SR design, e.g., numbers of sections and fields, and template use; (3) clinical impact of SR, e.g., on report quality and length, workload, and communication with clinicians; and (4) preferences for an oncology-focused structured CT report. Data analysis comprised descriptive statistics, chi-square tests, and Spearman correlation coefficients. RESULTS: A total of 200 radiologists from 51 countries completed the survey: 57.0% currently utilized SR (57%), with a lower proportion within than outside of Europe (51.0 vs. 72.7%; p = 0.006). Among SR users, the majority observed markedly increased report quality (62.3%) and easier comparison to previous exams (53.5%), a slightly lower error rate (50.9%), and fewer calls/emails by clinicians (78.9%) due to SR. The perceived impact of SR on communication with clinicians (i.e., frequency of calls/emails) differed with radiologists' experience (p < 0.001), and experience also showed low but significant correlations with communication with clinicians (r = - 0.27, p = 0.003), report quality (r = 0.19, p = 0.043), and error rate (r = - 0.22, p = 0.016). Template use also affected the perceived impact of SR on report quality (p = 0.036). CONCLUSION: Radiologists regard SR in oncologic imaging favorably, with perceived positive effects on report quality, error rate, comparison of serial exams, and communication with clinicians. CLINICAL RELEVANCE STATEMENT: Radiologists believe that structured reporting in oncologic imaging improves report quality, decreases the error rate, and enables better communication with clinicians. Implementation of structured reporting in Europe is currently below the international level and needs society endorsement. KEY POINTS: • The majority of oncologic imaging specialists (57% overall; 51% in Europe) use structured reporting in clinical practice. • The vast majority of oncologic imaging specialists use templates (92.1%), which are typically cancer-specific (76.2%). • Structured reporting is perceived to markedly improve report quality, communication with clinicians, and comparison to prior scans.

3.
Eur Radiol ; 33(9): 6168-6178, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37166494

RESUMEN

OBJECTIVES: To explore the relationship between indices of hypoxia and vascular function from 18F-fluoromisonidazole ([18F]-FMISO)-PET/MRI with immunohistochemical markers of hypoxia and vascularity in oestrogen receptor-positive (ER +) breast cancer. METHODS: Women aged > 18 years with biopsy-confirmed, treatment-naïve primary ER + breast cancer underwent [18F]-FMISO-PET/MRI prior to surgery. Parameters of vascular function were derived from DCE-MRI using the extended Tofts model, whilst hypoxia was assessed using the [18F]-FMISO influx rate constant, Ki. Histological tumour sections were stained with CD31, hypoxia-inducible factor (HIF)-1α, and carbonic anhydrase IX (CAIX). The number of tumour microvessels, median vessel diameter, and microvessel density (MVD) were obtained from CD31 immunohistochemistry. HIF-1α and CAIX expression were assessed using histoscores obtained by multiplying the percentage of positive cells stained by the staining intensity. Regression analysis was used to study associations between imaging and immunohistochemistry variables. RESULTS: Of the lesions examined, 14/22 (64%) were ductal cancers, grade 2 or 3 (19/22; 86%), with 17/22 (77%) HER2-negative. [18F]-FMISO Ki associated negatively with vessel diameter (p = 0.03), MVD (p = 0.02), and CAIX expression (p = 0.002), whilst no significant relationships were found between DCE-MRI pharmacokinetic parameters and immunohistochemical variables. HIF-1α did not significantly associate with any PET/MR imaging indices. CONCLUSION: Hypoxia measured by [18F]-FMISO-PET was associated with increased CAIX expression, low MVD, and smaller vessel diameters in ER + breast cancer, further corroborating the link between inadequate vascularity and hypoxia in ER + breast cancer. KEY POINTS: • Hypoxia, measured by [18F]-FMISO-PET, was associated with low microvessel density and small vessel diameters, corroborating the link between inadequate vascularity and hypoxia in ER + breast cancer. • Increased CAIX expression was associated with higher levels of hypoxia measured by [18F]-FMISO-PET. • Morphologic and functional abnormalities of the tumour microvasculature are the major determinants of hypoxia in cancers and support the previously reported perfusion-driven character of hypoxia in breast carcinomas.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/patología , Inmunohistoquímica , Hipoxia , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Subunidad alfa del Factor 1 Inducible por Hipoxia
4.
Proc Natl Acad Sci U S A ; 117(4): 2092-2098, 2020 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-31964840

RESUMEN

Our purpose is to investigate the feasibility of imaging tumor metabolism in breast cancer patients using 13C magnetic resonance spectroscopic imaging (MRSI) of hyperpolarized 13C label exchange between injected [1-13C]pyruvate and the endogenous tumor lactate pool. Treatment-naïve breast cancer patients were recruited: four triple-negative grade 3 cancers; two invasive ductal carcinomas that were estrogen and progesterone receptor-positive (ER/PR+) and HER2/neu-negative (HER2-), one grade 2 and one grade 3; and one grade 2 ER/PR+ HER2- invasive lobular carcinoma (ILC). Dynamic 13C MRSI was performed following injection of hyperpolarized [1-13C]pyruvate. Expression of lactate dehydrogenase A (LDHA), which catalyzes 13C label exchange between pyruvate and lactate, hypoxia-inducible factor-1 (HIF1α), and the monocarboxylate transporters MCT1 and MCT4 were quantified using immunohistochemistry and RNA sequencing. We have demonstrated the feasibility and safety of hyperpolarized 13C MRI in early breast cancer. Both intertumoral and intratumoral heterogeneity of the hyperpolarized pyruvate and lactate signals were observed. The lactate-to-pyruvate signal ratio (LAC/PYR) ranged from 0.021 to 0.473 across the tumor subtypes (mean ± SD: 0.145 ± 0.164), and a lactate signal was observed in all of the grade 3 tumors. The LAC/PYR was significantly correlated with tumor volume (R = 0.903, P = 0.005) and MCT 1 (R = 0.85, P = 0.032) and HIF1α expression (R = 0.83, P = 0.043). Imaging of hyperpolarized [1-13C]pyruvate metabolism in breast cancer is feasible and demonstrated significant intertumoral and intratumoral metabolic heterogeneity, where lactate labeling correlated with MCT1 expression and hypoxia.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Neoplasias de la Mama/genética , Neoplasias de la Mama/metabolismo , Neoplasias de la Mama/patología , Isótopos de Carbono/química , Isótopos de Carbono/metabolismo , Femenino , Humanos , Subunidad alfa del Factor 1 Inducible por Hipoxia/genética , Subunidad alfa del Factor 1 Inducible por Hipoxia/metabolismo , L-Lactato Deshidrogenasa/genética , L-Lactato Deshidrogenasa/metabolismo , Imagen por Resonancia Magnética/instrumentación , Transportadores de Ácidos Monocarboxílicos/genética , Transportadores de Ácidos Monocarboxílicos/metabolismo , Proteínas Musculares/genética , Proteínas Musculares/metabolismo , Ácido Pirúvico/química , Ácido Pirúvico/metabolismo , Simportadores/genética , Simportadores/metabolismo
5.
Radiology ; 302(1): 88-104, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34665034

RESUMEN

Background Advances in computer processing and improvements in data availability have led to the development of machine learning (ML) techniques for mammographic imaging. Purpose To evaluate the reported performance of stand-alone ML applications for screening mammography workflow. Materials and Methods Ovid Embase, Ovid Medline, Cochrane Central Register of Controlled Trials, Scopus, and Web of Science literature databases were searched for relevant studies published from January 2012 to September 2020. The study was registered with the PROSPERO International Prospective Register of Systematic Reviews (protocol no. CRD42019156016). Stand-alone technology was defined as a ML algorithm that can be used independently of a human reader. Studies were quality assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 and the Prediction Model Risk of Bias Assessment Tool, and reporting was evaluated using the Checklist for Artificial Intelligence in Medical Imaging. A primary meta-analysis included the top-performing algorithm and corresponding reader performance from which pooled summary estimates for the area under the receiver operating characteristic curve (AUC) were calculated using a bivariate model. Results Fourteen articles were included, which detailed 15 studies for stand-alone detection (n = 8) and triage (n = 7). Triage studies reported that 17%-91% of normal mammograms identified could be read by adapted screening, while "missing" an estimated 0%-7% of cancers. In total, an estimated 185 252 cases from three countries with more than 39 readers were included in the primary meta-analysis. The pooled sensitivity, specificity, and AUC was 75.4% (95% CI: 65.6, 83.2; P = .11), 90.6% (95% CI: 82.9, 95.0; P = .40), and 0.89 (95% CI: 0.84, 0.98), respectively, for algorithms, and 73.0% (95% CI: 60.7, 82.6), 88.6% (95% CI: 72.4, 95.8), and 0.85 (95% CI: 0.78, 0.97), respectively, for readers. Conclusion Machine learning (ML) algorithms that demonstrate a stand-alone application in mammographic screening workflows achieve or even exceed human reader detection performance and improve efficiency. However, this evidence is from a small number of retrospective studies. Therefore, further rigorous independent external prospective testing of ML algorithms to assess performance at preassigned thresholds is required to support these claims. ©RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Whitman and Moseley in this issue.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Aprendizaje Automático , Mamografía/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Flujo de Trabajo , Femenino , Humanos , Sensibilidad y Especificidad
6.
Eur Radiol ; 32(1): 661-670, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34324025

RESUMEN

OBJECTIVES: To evaluate the diagnostic performance in the assessment setting of three protocols: one-view wide-angle digital breast tomosynthesis (WA-DBT) with synthetic mammography (SM), two-view WA-DBT/SM, and two-view digital mammography (DM). METHODS: Included in this retrospective study were patients who underwent bilateral two-view DM and WA-DBT. SM were reconstructed from the WA-DBT data. The standard of reference was histology and/or 2 years follow-up. Included were 205 women with 179 lesions (89 malignant, 90 benign). Four blinded readers randomly evaluated images to assess density, lesion type, and level of suspicion according to BI-RADS. Three protocols were evaluated: two-view DM, one-view (mediolateral oblique) WA-DBT/SM, and two-view WA-DBT/SM. Detection rate, sensitivity, specificity, and accuracy were calculated and compared using multivariate analysis. Reading time was assessed. RESULTS: The detection rate was higher with two-view WA-DBT/SM (p = 0.063). Sensitivity was higher for two-view WA-DBT/SM compared to two-view DM (p = 0.001) and one-view WA-DBT/SM (p = 0.058). No significant differences in specificity were found. Accuracy was higher with both one-view WA-DBT/SM and two-view WA-DBT/SM compared to DM (p = 0.003 and > 0.001, respectively). Accuracy did not differ between one- and two-view WA-DBT/SM. Two-view WA-DBT/SM performed better for masses and asymmetries. Reading times were significantly longer when WA-DBT was evaluated. CONCLUSIONS: One-view and two-view WA-DBT/SM can achieve a higher diagnostic performance compared to two-view DM. The detection rate and sensitivity were highest with two-view WA-DBT/SM. Two-view WA-DBT/SM appears to be the most appropriate tool for the assessment of breast lesions. KEY POINTS: • Detection rate with two-view wide-angle digital breast tomosynthesis (WA-DBT) is significantly higher than with two-view digital mammography in the assessment setting. • Diagnostic accuracy of one-view and two-view WA-DBT with synthetic mammography (SM) in the assessment setting is higher than that of two-view digital mammography. • Compared to one-view WA-DBT with SM, two-view WA-DBT with SM seems to be the most appropriate tool for the assessment of breast lesions.


Asunto(s)
Neoplasias de la Mama , Paraganglioma , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Técnicas Histológicas , Humanos , Mamografía , Estudios Retrospectivos , Sensibilidad y Especificidad
7.
Br J Cancer ; 124(7): 1187-1198, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33504974

RESUMEN

Metabolic reprogramming is one of the hallmarks of cancer and includes the Warburg effect, which is exhibited by many tumours. This can be exploited by positron emission tomography (PET) as part of routine clinical cancer imaging. However, an emerging and alternative method to detect altered metabolism is carbon-13 magnetic resonance imaging (MRI) following injection of hyperpolarised [1-13C]pyruvate. The technique increases the signal-to-noise ratio for the detection of hyperpolarised 13C-labelled metabolites by several orders of magnitude and facilitates the dynamic, noninvasive imaging of the exchange of 13C-pyruvate to 13C-lactate over time. The method has produced promising preclinical results in the area of oncology and is currently being explored in human imaging studies. The first translational studies have demonstrated the safety and feasibility of the technique in patients with prostate, renal, breast and pancreatic cancer, as well as revealing a successful response to treatment in breast and prostate cancer patients at an earlier stage than multiparametric MRI. This review will focus on the strengths of the technique and its applications in the area of oncological body MRI including noninvasive characterisation of disease aggressiveness, mapping of tumour heterogeneity, and early response assessment. A comparison of hyperpolarised 13C-MRI with state-of-the-art multiparametric MRI is likely to reveal the unique additional information and applications offered by the technique.


Asunto(s)
Isótopos de Carbono/metabolismo , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias/patología , Animales , Humanos , Neoplasias/metabolismo
8.
Magn Reson Med ; 85(5): 2370-2376, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33274790

RESUMEN

PURPOSE: The aim of the study was to investigate whether incorrectly compensated eddy currents are the source of persistent X-nuclear spectroscopy and imaging artifacts, as well as methods to correct this. METHODS: Pulse-acquire spectra were collected for 1 H and X-nuclei (23 Na or 31 P) using the minimum TR permitted on a 3T clinical MRI system. Data were collected in 3 orientations (axial, sagittal, and coronal) with the spoiler gradient at the end of the TR applied along the slice direction for each. Modifications to system calibration files to tailor eddy current compensation for each X-nucleus were developed and applied, and data were compared with and without these corrections for: slice-selective MRS (for 23 Na and 31 P), 2D spiral trajectories (for 13 C), and 3D cones trajectories (for 23 Na). RESULTS: Line-shape distortions characteristic of eddy currents were demonstrated for X-nuclei, which were not seen for 1 H. The severity of these correlated with the amplitude of the eddy current frequency compensation term applied by the system along the axis of the applied spoiler gradient. A proposed correction to eddy current compensation, taking account of the gyromagnetic ratio, was shown to dramatically reduce these distortions. The same correction was also shown to improve data quality of non-Cartesian imaging (2D spiral and 3D cones trajectories). CONCLUSION: A simple adaptation of the default compensation for eddy currents was shown to eliminate a range of artifacts detected on X-nuclear spectroscopy and imaging.


Asunto(s)
Artefactos , Imagen por Resonancia Magnética , Algoritmos , Encéfalo , Calibración , Fantasmas de Imagen
9.
Eur Radiol ; 31(1): 333-344, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32725330

RESUMEN

OBJECTIVES: Hypoxia is associated with poor prognosis and treatment resistance in breast cancer. However, the temporally variant nature of hypoxia can complicate interpretation of imaging findings. We explored the relationship between hypoxia and vascular function in breast tumours through combined 18F-fluoromisonidazole (18 F-FMISO) PET/MRI, with simultaneous assessment circumventing the effect of temporal variation in hypoxia and perfusion. METHODS: Women with histologically confirmed, primary breast cancer underwent a simultaneous 18F-FMISO-PET/MR examination. Tumour hypoxia was assessed using influx rate constant Ki and hypoxic fractions (%HF), while parameters of vascular function (Ktrans, kep, ve, vp) and cellularity (ADC) were derived from dynamic contrast-enhanced (DCE) and diffusion-weighted (DW)-MRI, respectively. Additional correlates included histological subtype, grade and size. Relationships between imaging variables were assessed using Pearson correlation (r). RESULTS: Twenty-nine women with 32 lesions were assessed. Hypoxic fractions > 1% were observed in 6/32 (19%) cancers, while 18/32 (56%) tumours showed a %HF of zero. The presence of hypoxia in lesions was independent of histological subtype or grade. Mean tumour Ktrans correlated negatively with Ki (r = - 0.38, p = 0.04) and %HF (r = - 0.33, p = 0.04), though parametric maps exhibited intratumoural heterogeneity with hypoxic regions colocalising with both hypo- and hyperperfused areas. No correlation was observed between ADC and DCE-MRI or PET parameters. %HF correlated positively with lesion size (r = 0.63, p = 0.001). CONCLUSION: Hypoxia measured by 18F-FMISO-PET correlated negatively with Ktrans from DCE-MRI, supporting the hypothesis of perfusion-driven hypoxia in breast cancer. Intratumoural hypoxia-perfusion relationships were heterogeneous, suggesting that combined assessment may be needed for disease characterisation, which could be achieved using simultaneous multimodality imaging. KEY POINTS: • At the tumour level, hypoxia measured by 18F-FMISO-PET was negatively correlated with perfusion measured by DCE-MRI, which supports the hypothesis of perfusion-driven hypoxia in breast cancer. • No associations were observed between 18F-FMISO-PET parameters and tumour histology or grade, but tumour hypoxic fractions increased with lesion size. • Intratumoural hypoxia-perfusion relationships were heterogeneous, suggesting that the combined hypoxia-perfusion status of tumours may need to be considered for disease characterisation, which can be achieved via simultaneous multimodality imaging as reported here.


Asunto(s)
Neoplasias de la Mama , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Humanos , Hipoxia/diagnóstico por imagen , Imagen por Resonancia Magnética , Perfusión , Tomografía de Emisión de Positrones
10.
Eur Radiol ; 31(6): 3765-3772, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33315123

RESUMEN

PURPOSE: To develop a precision tissue sampling technique that uses computed tomography (CT)-based radiomic tumour habitats for ultrasound (US)-guided targeted biopsies that can be integrated in the clinical workflow of patients with high-grade serous ovarian cancer (HGSOC). METHODS: Six patients with suspected HGSOC scheduled for US-guided biopsy before starting neoadjuvant chemotherapy were included in this prospective study from September 2019 to February 2020. The tumour segmentation was performed manually on the pre-biopsy contrast-enhanced CT scan. Spatial radiomic maps were used to identify tumour areas with similar or distinct radiomic patterns, and tumour habitats were identified using the Gaussian mixture modelling. CT images with superimposed habitat maps were co-registered with US images by means of a landmark-based rigid registration method for US-guided targeted biopsies. The dice similarity coefficient (DSC) was used to assess the tumour-specific CT/US fusion accuracy. RESULTS: We successfully co-registered CT-based radiomic tumour habitats with US images in all patients. The median time between CT scan and biopsy was 21 days (range 7-30 days). The median DSC for tumour-specific CT/US fusion accuracy was 0.53 (range 0.79 to 0.37). The CT/US fusion accuracy was high for the larger pelvic tumours (DSC: 0.76-0.79) while it was lower for the smaller omental metastases (DSC: 0.37-0.53). CONCLUSION: We developed a precision tissue sampling technique that uses radiomic habitats to guide in vivo biopsies using CT/US fusion and that can be seamlessly integrated in the clinical routine for patients with HGSOC. KEY POINTS: • We developed a prevision tissue sampling technique that co-registers CT-based radiomics-based tumour habitats with US images. • The CT/US fusion accuracy was high for the larger pelvic tumours (DSC: 0.76-0.79) while it was lower for the smaller omental metastases (DSC: 0.37-0.53).


Asunto(s)
Neoplasias Ováricas , Tomografía Computarizada por Rayos X , Ecosistema , Femenino , Humanos , Neoplasias Ováricas/diagnóstico por imagen , Estudios Prospectivos , Ultrasonografía Intervencional
11.
Eur Radiol ; 30(6): 3558-3566, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32060715

RESUMEN

OBJECTIVES: (1) To assess the methodological quality of radiomics studies investigating histological subtypes, therapy response, and survival in patients with renal cell carcinoma (RCC) and (2) to determine the risk of bias in these radiomics studies. METHODS: In this systematic review, literature published since 2000 on radiomics in RCC was included and assessed for methodological quality using the Radiomics Quality Score. The risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool and a meta-analysis of radiomics studies focusing on differentiating between angiomyolipoma without visible fat and RCC was performed. RESULTS: Fifty-seven studies investigating the use of radiomics in renal cancer were identified, including 4590 patients in total. The average Radiomics Quality Score was 3.41 (9.4% of total) with good inter-rater agreement (ICC 0.96, 95% CI 0.93-0.98). Three studies validated results with an independent dataset, one used a publically available validation dataset. None of the studies shared the code, images, or regions of interest. The meta-analysis showed moderate heterogeneity among the included studies and an odds ratio of 6.24 (95% CI 4.27-9.12; p < 0.001) for the differentiation of angiomyolipoma without visible fat from RCC. CONCLUSIONS: Radiomics algorithms show promise for answering clinical questions where subjective interpretation is challenging or not established. However, the generalizability of findings to prospective cohorts needs to be demonstrated in future trials for progression towards clinical translation. Improved sharing of methods including code and images could facilitate independent validation of radiomics signatures. KEY POINTS: • Studies achieved an average Radiomics Quality Score of 10.8%. Common reasons for low Radiomics Quality Scores were unvalidated results, retrospective study design, absence of open science, and insufficient control for multiple comparisons. • A previous training phase allowed reaching almost perfect inter-rater agreement in the application of the Radiomics Quality Score. • Meta-analysis of radiomics studies distinguishing angiomyolipoma without visible fat from renal cell carcinoma show moderate diagnostic odds ratios of 6.24 and moderate methodological diversity.


Asunto(s)
Angiomiolipoma/diagnóstico por imagen , Carcinoma de Células Renales/diagnóstico por imagen , Informática , Neoplasias Renales/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Angiomiolipoma/patología , Carcinoma de Células Renales/patología , Diagnóstico Diferencial , Humanos , Neoplasias Renales/patología
12.
Neuroimage ; 189: 171-179, 2019 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-30639333

RESUMEN

Hyperpolarized 13C Magnetic Resonance Imaging (13C-MRI) provides a highly sensitive tool to probe tissue metabolism in vivo and has recently been translated into clinical studies. We report the cerebral metabolism of intravenously injected hyperpolarized [1-13C]pyruvate in the brain of healthy human volunteers for the first time. Dynamic acquisition of 13C images demonstrated 13C-labeling of both lactate and bicarbonate, catalyzed by cytosolic lactate dehydrogenase and mitochondrial pyruvate dehydrogenase respectively. This demonstrates that both enzymes can be probed in vivo in the presence of an intact blood-brain barrier: the measured apparent exchange rate constant (kPL) for exchange of the hyperpolarized 13C label between [1-13C]pyruvate and the endogenous lactate pool was 0.012 ±â€¯0.006 s-1 and the apparent rate constant (kPB) for the irreversible flux of [1-13C]pyruvate to [13C]bicarbonate was 0.002 ±â€¯0.002 s-1. Imaging also revealed that [1-13C]pyruvate, [1-13C]lactate and [13C]bicarbonate were significantly higher in gray matter compared to white matter. Imaging normal brain metabolism with hyperpolarized [1-13C]pyruvate and subsequent quantification, have important implications for interpreting pathological cerebral metabolism in future studies.


Asunto(s)
Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Isótopos de Carbono , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Ácido Pirúvico , Adulto , Femenino , Humanos , Masculino
13.
J Magn Reson Imaging ; 49(4): 1157-1165, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30552829

RESUMEN

BACKGROUND: Contrast-enhanced magnetic resonance imaging (CE-MRI) of the breast is highly sensitive for breast cancer detection. Multichannel coils and 3T scanners can increase signal, spatial, and temporal resolution. In addition, the T1 -reduction effect of a gadolinium-based contrast agent (GBCA) is higher at 3T. Thus, it might be possible to reduce the dose of GBCA at 3T without losing diagnostic information. PURPOSE: To compare a three-quarter (0.075 mmol/kg) dose of the high-relaxivity GBCA gadobenate dimeglumine, with a 1.5-fold higher than on-label dose (0.15 mmol/kg) of gadoterate meglumine for breast lesion detection and characterization at 3T CE-MRI. STUDY TYPE: Prospective, randomized, intraindividual comparative study. POPULATION: Eligible were patients with imaging abnormalities (BI-RADS 0, 4, 5) on conventional imaging. Each patient underwent two examinations, 24-72 hours apart, one with 0.075 mmol/kg gadobenate and the other with 0.15 mmol/kg gadoterate administered in a randomized order. In all, 109 patients were prospectively recruited. FIELD STRENGTH/SEQUENCE: 3T MRI with a standard breast protocol (dynamic-CE, T2 w-TSE, STIR-T2 w, DWI). ASSESSMENT: Histopathology was the standard of reference. Three blinded, off-site breast radiologists evaluated the examinations using the BI-RADS lexicon. STATISTICAL TESTS: Lesion detection, sensitivity, specificity, and diagnostic accuracy were calculated per-lesion and per-region, and compared by univariate and multivariate analysis (Generalized Estimating Equations, GEE). RESULTS: Five patients were excluded, leaving 104 women with 142 histologically verified breast lesions (109 malignant, 33 benign) available for evaluation. Lesion detection with gadobenate (84.5-88.7%) was not inferior to gadoterate (84.5-90.8%) (P ≥ 0.165). At per-region analysis, gadobenate demonstrated higher specificity (96.4-98.7% vs. 92.6-97.3%, P ≤ 0.007) and accuracy (96.3-97.8% vs. 93.6-96.1%, P ≤ 0.001) compared with gadoterate. Multivariate analysis demonstrated superior, reader-independent diagnostic accuracy with gadobenate (odds ratio = 1.7, P < 0.001 using GEE). DATA CONCLUSION: A 0.075 mmol/kg dose of the high-relaxivity contrast agent gadobenate was not inferior to a 0.15 mmol/kg dose of gadoterate for breast lesion detection. Gadobenate allowed increased specificity and accuracy. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:1157-1165.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Imagen por Resonancia Magnética , Meglumina/análogos & derivados , Compuestos Organometálicos/farmacología , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste/farmacología , Estudios Cruzados , Método Doble Ciego , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Meglumina/farmacología , Persona de Mediana Edad , Análisis Multivariante , Estudios Prospectivos , Sensibilidad y Especificidad
15.
Ultraschall Med ; 40(6): 757-763, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29879743

RESUMEN

PURPOSE: Optoacoustic imaging with ultrasound (OPUS) can assess in-vivo perfusion/oxygenation through surrogate measures of oxy, deoxy and total hemoglobin content in tissues. The primary aim of our study was to evaluate the ability of OPUS to detect physiological changes in the breast during the menstrual cycle and to determine qualitative/quantitative metrics of normal parenchymal tissue in pre-/post-menopausal women. The secondary aim was to assess the technique's repeatability. MATERIALS AND METHODS: We performed a prospective ethically approved study in volunteers using OPUS (700, 800 and 850 nm wavelengths) in the proliferative/follicular and secretory phase of the menstrual cycle. Regions of interest (ROIs) were drawn on the most superficial region of fibroglandular tissue and same-day intra-observer repeatability was assessed. We used t-tests to interrogate differences in the OPUS measurements due to hormonal changes and interclass correlation coefficients/Bland-Altman plots to evaluate the repeatability of mean ROI signal intensities. RESULTS: 22 pre-menopausal and 8 post-menopausal volunteers were recruited. 21 participants underwent repeatability examinations. OPUS intensity values were significantly higher (p < 0.0001) at all excitation wavelengths in the secretory compared to the proliferative/follicular phase. Post-menopausal volunteers showed similar optoacoustic values to the proliferative/follicular phase of pre-menopausal volunteers. The repeatability of the technique was comparable to other handheld ultrasound modalities. CONCLUSION: OPUS detects changes in perfusion/vascularity related to the menstrual cycle and menopausal status of breast parenchyma.


Asunto(s)
Neoplasias de la Mama , Hormonas , Mama , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Hormonas/fisiología , Humanos , Ciclo Menstrual , Óptica y Fotónica , Estudios Prospectivos
16.
J Neurooncol ; 140(1): 173-178, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30008154

RESUMEN

OBJECTIVES: The purpose of this study was to evaluate the prognostic relevance of temporal muscle thickness (TMT) in melanoma patients with newly diagnosed brain metastases. METHODS: TMT was retrospectively assessed in 146 melanoma patients with newly diagnosed brain metastases on cranial magnetic resonance images. Chart review was used to retrieve clinical parameters, including disease-specific graded prognostic assessment (DS-GPA) and survival times. RESULTS: Patients with a TMT > median showed a statistically significant increase in survival time (13 months) compared to patients with a TMT < median (5 months; p < 0.001; log rank test). A Cox regression model revealed that the risk of death was increased by 27.9% with every millimeter reduction in TMT. In the multivariate analysis, TMT (HR 0.724; 95% 0.642-0.816; < 0.001) and DS-GPA (HR 1.214; 95% CI 1.023-1.439; p = 0.026) showed a statistically significant correlation with overall survival. CONCLUSION: TMT is an independent predictor of survival in melanoma patients with brain metastases. This parameter may aid in patient selection for clinical trials or to the choice of different treatment options based on the determination of frail patient populations.


Asunto(s)
Neoplasias Encefálicas/patología , Neoplasias Encefálicas/secundario , Melanoma/patología , Músculo Temporal/patología , Adolescente , Adulto , Neoplasias Encefálicas/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Melanoma/diagnóstico por imagen , Pronóstico , Análisis de Regresión , Estudios Retrospectivos , Análisis de Supervivencia , Tomógrafos Computarizados por Rayos X , Adulto Joven
17.
Eur Radiol ; 28(11): 4766-4774, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29761359

RESUMEN

OBJECTIVES: To assess whether electronic cleansing (EC) of tagged residue and different computed tomography (CT) windows influence the size of colorectal polyps in CT colonography (CTC). METHODS: A database of 894 colonoscopy-validated CTC datasets of a low-prevalence cohort was retrospectively reviewed to identify patients with polyps ≥6 mm that were entirely submerged in tagged residue. Ten radiologists independently measured the largest diameter of each polyp, two-dimensionally, before and after EC in colon, bone, and soft-tissue-windows, in randomised order. Differences in size and polyp count before and after EC were calculated for size categories ≥6 mm and ≥10 mm. Statistical testing involved 95% confidence interval, intraclass correlation and mixed-model ANOVA. RESULTS: Thirty-seven patients with 48 polyps were included. Mean polyp size before EC was 9.8 mm in colon, 9.9 mm in bone and 8.2 mm in soft-tissue windows. After EC, the mean polyp size decreased significantly to 9.4 mm in colon, 9.1 mm in bone and 7.1 mm in soft-tissue windows. Compared to unsubtracted colon windows, EC, performed in colon, bone and soft-tissue windows, led to a shift of 6 (12,5%), 10 (20.8%) and 25 (52.1%) polyps ≥6 mm into the next smaller size category, thus affecting patient risk stratification. CONCLUSIONS: EC and narrow CT windows significantly reduce the size of polyps submerged in tagged residue. Polyp measurements should be performed in unsubtracted colon windows. KEY POINTS: • EC significantly reduces the size of polyps submerged in tagged residue. • Abdominal CT-window settings significantly underestimate 2D sizes of submerged polyps. • Size reduction in EC is significantly greater in narrow than wide windows. • Underestimation of polyp size due to EC may lead to inadequate treatment. • Polyp measurements should be performed in unsubtracted images using a colon window.


Asunto(s)
Pólipos del Colon/diagnóstico por imagen , Colonografía Tomográfica Computarizada/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Anciano , Algoritmos , Análisis de Varianza , Colonografía Tomográfica Computarizada/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estándares de Referencia , Estudios Retrospectivos , Sensibilidad y Especificidad
18.
Eur Radiol ; 27(9): 3799-3809, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28275900

RESUMEN

OBJECTIVES: To assess whether using the Tree flowchart obviates unnecessary magnetic resonance imaging (MRI)-guided biopsies in breast lesions only visible on MRI. METHODS: This retrospective IRB-approved study evaluated consecutive suspicious (BI-RADS 4) breast lesions only visible on MRI that were referred to our institution for MRI-guided biopsy. All lesions were evaluated according to the Tree flowchart for breast MRI by experienced readers. The Tree flowchart is a decision rule that assigns levels of suspicion to specific combinations of diagnostic criteria. Receiver operating characteristic (ROC) curve analysis was used to evaluate diagnostic accuracy. To assess reproducibility by kappa statistics, a second reader rated a subset of 82 patients. RESULTS: There were 454 patients with 469 histopathologically verified lesions included (98 malignant, 371 benign lesions). The area under the curve (AUC) of the Tree flowchart was 0.873 (95% CI: 0.839-0.901). The inter-reader agreement was almost perfect (kappa: 0.944; 95% CI 0.889-0.998). ROC analysis revealed exclusively benign lesions if the Tree node was ≤2, potentially avoiding unnecessary biopsies in 103 cases (27.8%). CONCLUSIONS: Using the Tree flowchart in breast lesions only visible on MRI, more than 25% of biopsies could be avoided without missing any breast cancer. KEY POINTS: • The Tree flowchart may obviate >25% of unnecessary MRI-guided breast biopsies. • This decrease in MRI-guided biopsies does not cause any false-negative cases. • The Tree flowchart predicts 30.6% of malignancies with >98% specificity. • The Tree's high specificity aids in decision-making after benign biopsy results.


Asunto(s)
Neoplasias de la Mama/clasificación , Biopsia Guiada por Imagen/normas , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Área Bajo la Curva , Neoplasias de la Mama/diagnóstico por imagen , Estudios Transversales , Técnicas de Apoyo para la Decisión , Femenino , Humanos , Persona de Mediana Edad , Curva ROC , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Procedimientos Innecesarios
19.
Eur Radiol ; 27(8): 3167-3173, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28050694

RESUMEN

OBJECTIVES: To evaluate the prognostic relevance of temporal muscle thickness (TMT) in brain metastasis patients. METHODS: We retrospectively analysed TMT on magnetic resonance (MR) images at diagnosis of brain metastasis in two independent cohorts of 188 breast cancer (BC) and 247 non-small cell lung cancer (NSCLC) patients (overall: 435 patients). RESULTS: Survival analysis using a Cox regression model showed a reduced risk of death by 19% with every additional millimetre of baseline TMT in the BC cohort and by 24% in the NSCLC cohort. Multivariate analysis included TMT and diagnosis-specific graded prognostic assessment (DS-GPA) as covariates in the BC cohort (TMT: HR 0.791/CI [0.703-0.889]/p < 0.001; DS-GPA: HR 1.433/CI [1.160-1.771]/p = 0.001), and TMT, gender and DS-GPA in the NSCLC cohort (TMT: HR 0.710/CI [0.646-0.780]/p < 0.001; gender: HR 0.516/CI [0.387-0.687]/p < 0.001; DS-GPA: HR 1.205/CI [1.018-1.426]/p = 0.030). CONCLUSION: TMT is easily and reproducibly assessable on routine MR images and is an independent predictor of survival in patients with newly diagnosed brain metastasis from BC and NSCLC. TMT may help to better define frail patient populations and thus facilitate patient selection for therapeutic measures or clinical trials. Further prospective studies are needed to correlate TMT with other clinical frailty parameters of patients. KEY POINTS: • TMT has an independent prognostic relevance in brain metastasis patients. • It is an easily and reproducibly parameter assessable on routine cranial MRI. • This parameter may aid in patient selection and stratification in clinical trials. • TMT may serve as surrogate marker for sarcopenia.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Músculo Temporal/patología , Adulto , Anciano , Encéfalo/patología , Neoplasias Encefálicas/mortalidad , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/secundario , Neoplasias de la Mama/patología , Carcinoma de Pulmón de Células no Pequeñas/patología , Femenino , Humanos , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Análisis Multivariante , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Análisis de Supervivencia , Músculo Temporal/diagnóstico por imagen
20.
Acta Radiol ; 58(2): 140-147, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27055918

RESUMEN

Background Virtual Touch IQ (VTIQ) is a novel technique of quantitative sonoelastography that applies acoustic radiation force impulse (ARFI). Purpose To evaluate breast ARFI imaging with VTIQ in the clinical setting, with regard to reproducibility and diagnostic performance, and to specify cutoff limits for the differentiation of benign and malignant lesions. Material and Methods This retrospective study included 83 patients with 85 breast lesions (51 benign, 34 malignant) who received ARFI imaging with VTIQ. Two independent ARFI measurements of each lesion were performed and shear wave velocities (SWV) of the lesion and the adjacent tissues were measured. A lesion-to-fat velocity ratio (L/F Ratio) was calculated for each lesion. Diagnostic performance of SWV measurements and L/F Ratios was evaluated with receiver operating curve (ROC) analysis. The intraclass correlation coefficient and Bland-Altman plots were used to evaluate measurement reproducibility. Results All measurements showed equal diagnostic performance, as measured by the area under the ROC curve (0.853 for SWV, 0.882 for the L/F Ratio). At a cutoff value of 3.23 m/s, sensitivity and specificity were 82.4% and 80.4%, respectively. An L/F Ratio cutoff value of 2.23 revealed a sensitivity and specificity of 89.7% and 76.5%. The reproducibility of the SWV measurements was moderate (limits of agreement, 40.3-44.4%) and higher than that of the L/F Ratios (54.5-60.2%). Conclusion ARFI imaging with VTIQ is a novel, moderately reproducible, quantitative elastography technique, which provides useful information for the differentiation of benign and malignant breast lesions in the clinical setting.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Ultrasonografía Mamaria/métodos , Adulto , Anciano , Anciano de 80 o más Años , Mama/diagnóstico por imagen , Estudios Transversales , Diagnóstico Diferencial , Femenino , Humanos , Persona de Mediana Edad , Curva ROC , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA