Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Br J Anaesth ; 131(1): 159-169, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36990827

RESUMEN

BACKGROUND: Diagnosis of perioperative anaphylaxis is often challenging. This study describes the utility of a newly developed tool for identifying patients with a high possibility of anaphylaxis, and aimed to investigate the frequency of anaphylaxis with each drug during the perioperative period in Japan. METHODS: This study included patients with anaphylaxis of Grade 2 or higher severity during general anaesthesia at 42 facilities across Japan in 2019 and 2020. We developed and adopted a unique objective evaluation tool yielding a composite score for diagnosing anaphylaxis, which includes the results of skin tests and basophil activation tests, and clinical scores for perioperative anaphylaxis. The number of cases using each drug and the total number of anaphylaxis cases were investigated to calculate the frequency of anaphylaxis. RESULTS: General anaesthesia was performed in 218 936 cases, which included 55 patients with suspected perioperative anaphylaxis. The developed composite score diagnosed 43 of them with a high probability of anaphylaxis. The causative agent was identified in 32 cases. Plasma histamine levels showed high diagnostic accuracy for anaphylaxis. The top causative agents were rocuronium (10 cases in 210 852 patients, 0.005%), sugammadex (7 cases in 150 629 patients, 0.005%), and cefazolin (7 cases in 106 005 patients, 0.007%). CONCLUSIONS: We developed a composite tool to diagnose anaphylaxis, and found that the combination of tryptase levels, skin testing, and basophil activation testing results and clinical score improved the certainty of anaphylaxis diagnosis. The incidence of perioperative anaphylaxis in our study was 1 in about 5000 general anaesthesia cases. CLINICAL TRIAL REGISTRATION: UMIN000035350.


Asunto(s)
Anafilaxia , Hipersensibilidad a las Drogas , Humanos , Anafilaxia/diagnóstico , Anafilaxia/epidemiología , Estudios Prospectivos , Pueblos del Este de Asia , Anestesia General/efectos adversos , Alérgenos , Hipersensibilidad a las Drogas/diagnóstico , Hipersensibilidad a las Drogas/epidemiología
2.
J Cardiothorac Vasc Anesth ; 36(5): 1380-1386, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34518101

RESUMEN

OBJECTIVE: Inflammatory responses play major roles in the development of acute lung injury following lung cancer surgery. The authors tested the hypothesis that thoracic epidural anesthesia (TEA) during surgery could attenuate both systemic and local inflammatory cytokine productions in patients undergoing lung cancer surgery. DESIGN: A prospective randomized controlled trial. SETTING: At Keio University Hospital, Tokyo, Japan. PARTICIPANTS: Patients scheduled for lung cancer surgery. INTERVENTIONS: Sixty patients were randomly allocated into two groups (n = 30 each group): the epidural group (group E), in which anesthesia was maintained with propofol, fentanyl, rocuronium, and epidural anesthesia with 0.25% levobupivacaine; or the remifentanil group (group R), in which a remifentanil infusion was used as a potent analgesia instead of epidural anesthesia. MEASUREMENTS AND MAIN RESULTS: The lung epithelial lining fluid (ELF) and blood sampling were collected prior to one-lung ventilation (OLV) initiation (T1) and at 30 minutes after the end of OLV (T2). The concentrations of tumor necrosis factor (TNF)-α, interleukin (IL)-6, and IL-10 in the ELF at T2 were increased significantly compared with those at T1 in both groups. The ELF concentration of IL-6 in group E was significantly lower than that in group R at T2 (median [interquartile range]: 39.7 [13.8-80.2] versus 76.1 [44.9-138.2], p = 0.008). Plasma IL-6 concentrations at T2, which increased in comparison to that at T1, were not significantly different between the two groups. The plasma concentrations of TNF-α did not change in both groups. CONCLUSIONS: This randomized clinical trial suggested that TEA could attenuate local inflammatory responses in the lungs during lung cancer surgery.


Asunto(s)
Anestesia Epidural , Neoplasias Pulmonares , Ventilación Unipulmonar , Anestesia General , Humanos , Interleucina-6 , Neoplasias Pulmonares/cirugía , Estudios Prospectivos , Remifentanilo
3.
J Anesth ; 34(2): 303-307, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31916012

RESUMEN

Ringer's ethyl pyruvate solution (REPS) has been protective against experimental renal, intestinal, and spinal ischemia and may be useful for organ protection in major vascular surgery. The purpose of this study was to investigate whether REPS attenuates organ injury in a rabbit model of supraceliac aortic cross-clamp that simulates thoracoabdominal aortic surgery. Following the Institutional Animal Care and Use Committee's approval, 20 rabbits were undergone cross-clamping of the supraceliac thoracic aorta for 30 min, and observed for 180 min after reperfusion. Either REPS (33 mg/kg/h of ethyl pyruvate) or Ringer's lactate solution were infused throughout the study period. Arterial pressure and aortic blood flow were continuously monitored. Blood lactate concentration, serum transaminase levels, neutrophil activation, and urinary N-acetyl-beta-glucosaminidase (NAG) activity were evaluated. After reperfusion, supraceliac aortic blood flow was significantly higher, and urinary NAG was significantly lower in animals that received REPS, while the other parameters were not significantly different. In conclusion, REPS attenuated the reduction of aortic blood flow and urinary NAG elevation after the cross-clamp of supraceliac aorta.


Asunto(s)
Isquemia , Daño por Reperfusión , Animales , Soluciones Isotónicas , Riñón , Conejos , Reperfusión , Daño por Reperfusión/prevención & control
4.
Anesth Analg ; 128(5): 909-916, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-29847379

RESUMEN

BACKGROUND: Previous work in the field of medical informatics has shown that rules-based algorithms can be created to identify patients with various medical conditions; however, these techniques have not been compared to actual clinician notes nor has the ability to predict complications been tested. We hypothesize that a rules-based algorithm can successfully identify patients with the diseases in the Revised Cardiac Risk Index (RCRI). METHODS: Patients undergoing surgery at the University of California, Los Angeles Health System between April 1, 2013 and July 1, 2016 and who had at least 2 previous office visits were included. For each disease in the RCRI except renal failure-congestive heart failure, ischemic heart disease, cerebrovascular disease, and diabetes mellitus-diagnosis algorithms were created based on diagnostic and standard clinical treatment criteria. For each disease state, the prevalence of the disease as determined by the algorithm, International Classification of Disease (ICD) code, and anesthesiologist's preoperative note were determined. Additionally, 400 American Society of Anesthesiologists classes III and IV cases were randomly chosen for manual review by an anesthesiologist. The sensitivity, specificity, accuracy, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve were determined using the manual review as a gold standard. Last, the ability of the RCRI as calculated by each of the methods to predict in-hospital mortality was determined, and the time necessary to run the algorithms was calculated. RESULTS: A total of 64,151 patients met inclusion criteria for the study. In general, the incidence of definite or likely disease determined by the algorithms was higher than that detected by the anesthesiologist. Additionally, in all disease states, the prevalence of disease was always lowest for the ICD codes, followed by the preoperative note, followed by the algorithms. In the subset of patients for whom the records were manually reviewed, the algorithms were generally the most sensitive and the ICD codes the most specific. When computing the modified RCRI using each of the methods, the modified RCRI from the algorithms predicted in-hospital mortality with an area under the receiver operating characteristic curve of 0.70 (0.67-0.73), which compared to 0.70 (0.67-0.72) for ICD codes and 0.64 (0.61-0.67) for the preoperative note. On average, the algorithms took 12.64 ± 1.20 minutes to run on 1.4 million patients. CONCLUSIONS: Rules-based algorithms for disease in the RCRI can be created that perform with a similar discriminative ability as compared to physician notes and ICD codes but with significantly increased economies of scale.


Asunto(s)
Informática Médica/métodos , Infarto del Miocardio/diagnóstico , Medición de Riesgo/métodos , Adulto , Anciano , Algoritmos , Anestesiología , Área Bajo la Curva , Comorbilidad , Bases de Datos Factuales , Complicaciones de la Diabetes/terapia , Registros Electrónicos de Salud , Femenino , Insuficiencia Cardíaca/complicaciones , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Isquemia Miocárdica/complicaciones , Reconocimiento de Normas Patrones Automatizadas , Complicaciones Posoperatorias/epidemiología , Prevalencia , Curva ROC , Insuficiencia Renal/complicaciones , Factores de Riesgo , Programas Informáticos
5.
J Clin Monit Comput ; 33(3): 385-392, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29948667

RESUMEN

Hemodynamic monitoring is mandatory for perioperative management of cardiac surgery. Recently, the estimated continuous cardiac output (esCCO) system, which can monitor cardiac output (CO) non-invasively based on pulse wave transit time, has been developed. Patients who underwent cardiovascular surgeries with hemodynamics monitoring using arterial pressure-based CO (APCO) were eligible for this study. Hemodynamic monitoring using esCCO and APCO was initiated immediately after intensive care unit admission. CO values measured using esCCO and APCO were collected every 6 h, and stroke volume variation (SVV) data were obtained every hour while patients were mechanically ventilated. Correlation and Bland-Altman analyses were used to compare APCO and esCCO. Welch's analysis of variance, and four-quadrant plot and polar plot analyses were performed to evaluate the effect of time course, and the trending ability. A p-value < 0.05 was considered statistically significant. Twenty-one patients were included in this study, and 143 and 146 datasets for CO and SVV measurement were analyzed. Regarding CO, the correlation analysis showed that APCO and esCCO were significantly correlated (r = 0.62), and the bias ± precision and percentage error were 0.14 ± 1.94 (L/min) and 69%, respectively. The correlation coefficient, bias ± precision, and percentage error for SVV evaluation were 0.4, - 3.79 ± 5.08, and 99%, respectively. The time course had no effects on the biases between CO and SVV. Concordance rates were 80.3 and 75.7% respectively. While CO measurement with esCCO can be a reliable monitor after cardiovascular surgeries, SVV measurement with esCCO may require further improvement.


Asunto(s)
Gasto Cardíaco , Hemodinámica , Análisis de la Onda del Pulso , Volumen Sistólico , Anciano , Algoritmos , Presión Arterial , Presión Sanguínea , Calibración , Procedimientos Quirúrgicos Cardíacos , Femenino , Humanos , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Oximetría , Admisión del Paciente , Probabilidad , Estudios Prospectivos , Reproducibilidad de los Resultados , Respiración Artificial
6.
J Anesth ; 32(4): 599-607, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29931389

RESUMEN

BACKGROUND: Both anesthetic-induced and ischemic preconditioning are protective against hepatic ischemia-reperfusion injury. However, the effects of these preventive methods on the metabolic function remain to be elucidated. We investigated the anesthetic conditioning and ischemic preconditioning on the metabolic function of the rabbit model of hepatic ischemia-reperfusion. METHODS: After approval by the institutional animal care and use committee, 36 Japanese White rabbits underwent partial hepatic ischemia for 90 min either under sevoflurane or propofol anesthesia. All the rabbits underwent 90 min of hepatic ischemia, and half of the rabbits in each group underwent additional 10-min ischemia and 10-min reperfusion before index ischemia. Hepatic microvascular blood flow was intermittently measured during reperfusion period, and galactose clearance, serum aminotransferase activities, and lactate concentrations were determined 180 min after reperfusion. RESULTS: Neither anesthetic conditioning with sevoflurane nor ischemic preconditioning altered hepatic microvascular blood flow during reperfusion and serum transaminase activities after reperfusion. However, galactose clearance of reperfused liver was significantly higher under sevoflurane anesthesia than propofol (0.016 ± 0.005/min vs. 0.011 ± 0.004/min). Statistically significant interaction between anesthetic choice and application of ischemic preconditioning suggests that the ischemic preconditioning is selectively protective under propofol anesthesia. Increase of blood lactate concentration was significantly suppressed under sevoflurane anesthesia compared to propofol (1.5 ± 0.8 vs. 3.9 ± 1.4 mmol/l) without any statistically significant interaction with the application of ischemic preconditioning. CONCLUSION: Sevoflurane attenuated the decrease of galactose clearance and increase of the blood lactate after reperfusion compared to propofol. Application of ischemic preconditioning was significantly protective under propofol anesthesia.


Asunto(s)
Anestésicos por Inhalación/farmacología , Precondicionamiento Isquémico/métodos , Hepatopatías/prevención & control , Daño por Reperfusión/fisiopatología , Anestesia/métodos , Animales , Modelos Animales de Enfermedad , Hemodinámica/efectos de los fármacos , Masculino , Propofol/farmacología , Conejos , Sevoflurano/farmacología
7.
Anesth Analg ; 125(5): 1784-1792, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-29049123

RESUMEN

BACKGROUND: The United States is in the midst of an opioid epidemic, and opioid use disorder often begins with a prescription for acute pain. The perioperative period represents an important opportunity to prevent chronic opioid use, and recently there has been a paradigm shift toward implementation of enhanced recovery after surgery (ERAS) protocols that promote opioid-free and multimodal analgesia. The objective of this study was to assess the impact of an ERAS intervention for colorectal surgery on discharge opioid prescribing practices. METHODS: We conducted a historical-prospective quality improvement study of an ERAS protocol implemented for patients undergoing colorectal surgery with a focus on the opioid-free and multimodal analgesia components of the pathway. We compared patients undergoing colorectal surgery 1 year before implementation (June 15, 2015, to June 14, 2016) and 1 year after implementation (June 15, 2016, to June 14, 2017). RESULTS: Before the ERAS intervention, opioids at discharge were not significantly increasing (1% per month; 95% confidence interval [CI], -1% to 3%; P = .199). Immediately after the ERAS intervention, opioid prescriptions were not significantly lower (13%; 95% CI, -30% to 3%; P = .110). After the intervention, the rate of opioid prescriptions at discharge did not decrease significantly 1% (95% CI, -3% to 1%) compared to the pre-period rate (P = .399). Subgroup analysis showed that in patients with a combination of low discharge pain scores, no preoperative opioid use, and low morphine milligram equivalents consumption before discharge, the rate of discharge opioid prescription was 72% (95% CI, 61%-83%). CONCLUSIONS: This study is the first to report discharge opioid prescribing practices in an ERAS setting. Although an ERAS intervention for colorectal surgery led to an increase in opioid-free anesthesia and multimodal analgesia, we did not observe an impact on discharge opioid prescribing practices. The majority of patients were discharged with an opioid prescription, including those with a combination of low discharge pain scores, no preoperative opioid use, and low morphine milligram equivalents consumption before discharge. This observation in the setting of an ERAS pathway that promotes multimodal analgesia suggests that our findings are very likely to also be observed in non-ERAS settings and offers an opportunity to modify opioid prescribing practices on discharge after surgery. For opioid-free anesthesia and multimodal analgesia to influence the opioid epidemic, the dose and quantity of the opioids prescribed should be modified based on the information gathered by in-hospital pain scores and opioid use as well as pain history before admission.


Asunto(s)
Analgésicos no Narcóticos/administración & dosificación , Analgésicos Opioides/administración & dosificación , Colon/cirugía , Procedimientos Quirúrgicos del Sistema Digestivo/efectos adversos , Manejo del Dolor/métodos , Dolor Postoperatorio/tratamiento farmacológico , Alta del Paciente , Recto/cirugía , Adulto , Anciano , Analgésicos no Narcóticos/efectos adversos , Analgésicos Opioides/efectos adversos , Investigación sobre la Eficacia Comparativa , Esquema de Medicación , Prescripciones de Medicamentos , Quimioterapia Combinada , Femenino , Humanos , Masculino , Persona de Mediana Edad , Manejo del Dolor/efectos adversos , Dimensión del Dolor , Dolor Postoperatorio/diagnóstico , Dolor Postoperatorio/etiología , Pautas de la Práctica en Medicina , Evaluación de Programas y Proyectos de Salud , Estudios Prospectivos , Mejoramiento de la Calidad , Indicadores de Calidad de la Atención de Salud , Factores de Tiempo , Resultado del Tratamiento
8.
J Gastroenterol Hepatol ; 31(1): 145-54, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26189649

RESUMEN

BACKGROUND AND AIM: Because neutrophil gelatinase-associated lipocalin (NGAL) is known to provide significant bacteriostatic effects during infectious conditions, we tested the hypothesis that this protein is up-regulated and secreted into the intraluminal cavity of the gut under critically ill conditions and is thus responsible for the regulation of bacterial overgrowth. METHODS: With our institutional approval, male C57BL/6J mouse (6-7 weeks) were enrolled and applied for lipopolysaccharide or peritonitis model compared with naïve control. We assessed NGAL protein concentrations in intestinal lumen and up-regulation of NGAL expression in intestinal tissues in in vivo as well as ex vivo settings. Simultaneously, we examined the effects of NGAL protein administration on the growth of Escherichia coli (E. coli) in in vivo and in vitro experimental settings. The localization of NGAL in intestinal tissues and lumen was also assessed by immunohistological approach using NGAL antibody. RESULTS: Both lipopolysaccharide and peritonitis insults evoked the marked up-regulation of NGAL mRNA and protein levels in gut tissues such as crypt cells. In addition, the administration of NGAL protein significantly inhibited the outgrowth of enteric E. coli under both in vitro and in vivo conditions, accompanied by histological evidence. CONCLUSION: Neutrophil gelatinase-associated lipocalin protein accompanied by apparent bacteriostatic action accumulated in the intestinal wall and streamed into the mucosal layer during critically ill state, thereby possibly shaping microbiota homeostasis in the gut.


Asunto(s)
Proteínas de Fase Aguda/farmacología , Proteínas de Fase Aguda/fisiología , Intestinos/microbiología , Lipocalinas/farmacología , Lipocalinas/fisiología , Microbiota/efectos de los fármacos , Proteínas Oncogénicas/farmacología , Proteínas Oncogénicas/fisiología , Proteínas de Fase Aguda/genética , Proteínas de Fase Aguda/metabolismo , Animales , Enfermedad Crítica , Modelos Animales de Enfermedad , Escherichia coli/crecimiento & desarrollo , Expresión Génica , Homeostasis/efectos de los fármacos , Mucosa Intestinal/metabolismo , Lipocalina 2 , Lipocalinas/genética , Lipocalinas/metabolismo , Lipopolisacáridos , Masculino , Ratones Endogámicos C57BL , Microbiota/fisiología , Proteínas Oncogénicas/genética , Proteínas Oncogénicas/metabolismo , Peritonitis/microbiología , Regulación hacia Arriba
9.
Masui ; 65(10): 1054-1057, 2016 10.
Artículo en Japonés | MEDLINE | ID: mdl-30358288

RESUMEN

A 50-year-old man with type 2 diabetes mellitus was scheduled for laparoscopic partial liver resection. Six months prior to the surgery, he developed frequent hypoglycemic attacks and was diagnosed as anti-insulin antibody positive. The operation was performed under general anesthesia with epidural anesthesia. Intermit- tent and continuous insulin administration was required during liver resection due to persistent hyperglycemia. After termination of the liver resection, the patient exhibited uncontrolled hypo- and hypergly- cemia, and recovery from anesthesia was delayed due to severe hypoglycemia. He recovered immediately after 40% glucose administration. However, frequent glucose administration was required for two hours after transfer to the ICU due to hypoglycemia. It should be born in mind that preoperative poor glucose control might be caused by anti-insulin antibodies and lead to difficult perioperative glucose management.


Asunto(s)
Diabetes Mellitus Tipo 2/complicaciones , Hepatectomía , Hígado/cirugía , Anestesia Epidural/efectos adversos , Anestesia General/efectos adversos , Anticuerpos/inmunología , Glucemia/análisis , Glucosa/uso terapéutico , Humanos , Hiperglucemia/etiología , Hipoglucemia/etiología , Insulina/inmunología , Laparoscopía , Masculino , Persona de Mediana Edad
10.
Anesth Analg ; 121(1): 81-89, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25782996

RESUMEN

BACKGROUND: Neutrophil-derived lipocalin-2 exerts bacteriostatic effects through retardation of iron uptake by the Gram-negative organisms like Escherichia coli. We tested the hypothesis that the expression of lipocalin-2, a bacteriostatic protein, was upregulated by induction of surgical site infection (SSI) with E coli in healthy and diseased rats and that epidural anesthesia modulated its expression. METHODS: Male Wistar rats were randomized into a healthy or disease group, the latter of which was administered lipopolysaccharide. Both groups were further divided into 3 subgroups, the control, saline, and lidocaine groups: group healthy control (n = 10), healthy saline (n = 10), and healthy lidocaine (n = 10) versus group disease control (n = 15), disease saline (n = 18), and disease lidocaine (n = 19), respectively. While saline was epidurally administered to the control and saline groups, lidocaine was administered to the lidocaine groups. Except for the control groups, E coli was injected to the pseudosurgical site to mimic SSI after abdominal surgery. Plasma concentrations of inflammatory cytokine and lipocalin-2 were measured. At 72 hours, the surgical site tissues were obtained to evaluate mRNA expression of lipocalin-2 and E coli DNA expression. RESULTS: All disease subgroups showed markedly increased plasma inflammatory cytokines versus the healthy subgroups. Among the disease subgroups, plasma concentrations of lipocalin-2 and tissue mRNA expression of lipocalin-2 were significantly increased in group disease lidocaine versus the others. Concurrently, E coli DNA expression in the tissue specimens was also significantly lower in group disease lidocaine as compared with group disease saline. CONCLUSIONS: Epidural anesthesia was associated with an increase in the expression lipocalin-2 and a decrease in the expression of E coli DNA at pseudosurgical sites in sick but not healthy rats. These observations suggest a potential mechanism by which epidural anesthesia could reduce the risk of SSI.


Asunto(s)
Anestesia Epidural/métodos , Anestésicos Locales/farmacología , Infecciones por Escherichia coli/prevención & control , Escherichia coli/efectos de los fármacos , Lidocaína/farmacología , Lipocalinas/sangre , Infección de la Herida Quirúrgica/prevención & control , Animales , Citocinas/sangre , ADN Bacteriano/metabolismo , Modelos Animales de Enfermedad , Escherichia coli/genética , Escherichia coli/crecimiento & desarrollo , Infecciones por Escherichia coli/sangre , Infecciones por Escherichia coli/microbiología , Interacciones Huésped-Patógeno , Mediadores de Inflamación/sangre , Lipocalina 2 , Lipocalinas/genética , Masculino , ARN Mensajero/metabolismo , Ratas Wistar , Transducción de Señal/efectos de los fármacos , Infección de la Herida Quirúrgica/sangre , Infección de la Herida Quirúrgica/microbiología , Factores de Tiempo , Regulación hacia Arriba
11.
J Anesth ; 27(6): 901-8, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23736823

RESUMEN

PURPOSE: Atrial natriuretic peptide (ANP) has been known to be protective against hepatic ischemia/reperfusion injury. The purpose of this study was to verify the hypothesis that ANP conserves microvascular circulation and reduces ischemia-reperfusion injury in the in vivo rabbit model. METHODS: With IRB approval, 30 male Japanese white rabbits under pentobarbital anesthesia were studied. These animals were randomly assigned to the following three groups (n = 10 each): control, ANP, and sham group. Animals in the ANP group received continuous infusion of ANP at 0.1 µg/kg/min throughout the study period. Animals in control and ANP groups underwent 90 min of partial hepatic ischemia by clamping the right hepatic artery and portal vein. Descending aortic blood flow (AoF) was monitored with a transit-time ultrasound flowmeter. Hepatic tissue microvascular blood flow (HTBF) at both right (ischemic) and left (nonischemic) lobe was intermittently evaluated with the hydrogen clearance method. After 180 min of reperfusion, hepatic injury was determined with serum AST and ALT. Galactose clearance of reperfused right lobe was also measured as an indicator of hepatic metabolic function. Histopathological change and the number of apoptotic hepatocytes were also evaluated. RESULTS: Systemic hemodynamic data including mean arterial pressure, heart rate, and AoF did not differ among the three groups during the study period. ANP attenuated ischemia-induced right HTBF decrease. ANP also suppressed histopathological degeneration, apoptosis, and decline in galactose clearance after reperfusion. CONCLUSIONS: ANP attenuated hepatic microvascular dysfunction and hepatocyte injury after reperfusion without significant hemodynamic change.


Asunto(s)
Factor Natriurético Atrial/metabolismo , Factor Natriurético Atrial/farmacología , Hígado/metabolismo , Daño por Reperfusión/tratamiento farmacológico , Daño por Reperfusión/metabolismo , Animales , Apoptosis/efectos de los fármacos , Presión Arterial/efectos de los fármacos , Factor Natriurético Atrial/efectos de los fármacos , Galactosa/metabolismo , Frecuencia Cardíaca/efectos de los fármacos , Hemodinámica/efectos de los fármacos , Circulación Hepática/efectos de los fármacos , Pruebas de Función Hepática/métodos , Masculino , Microcirculación/efectos de los fármacos , Conejos , Distribución Aleatoria
12.
Masui ; 62(6): 714-7, 2013 Jun.
Artículo en Japonés | MEDLINE | ID: mdl-23815000

RESUMEN

A 22-year-old female was scheduled to undergo posterior thoracolumbar spinal fusion. She had been diagnosed with congenital antithrombin III (AT-III) deficiency by the onset of pulmonary embolism and deep vein thrombosis after the first operation at the age of 18. Thereafter she had taken warfarin, 5 mg daily, until 4 days before the surgery. Preoperatively, we administered AT-III products to regulate AT-III activity. The posterior spinal fusion was performed successfully without surgical complications. Postoperatively, we continued administration of AT-III products to maintain AT-III activity above 75%. We also used low dose unfractionated heparin with AT-III by continuous intravenous infusion. Heparin was administered with dose adjustment to achieve a target activated partial thromboplastin time of 45 to 60 seconds. After the activated partial thromboplastin time was stabilized in the target range, we started warfarin therapy (target international normalized ratio, 1.5 to 2.5) on postoperative day 16 and stopped administration of heparin on postoperative day 19. There was no thrombosis complications during the perioperative period. Good anticoagulant management was achieved in a patient with congenital AT-III deficiency undergoing posterior spinal fusion.


Asunto(s)
Anticoagulantes/uso terapéutico , Deficiencia de Antitrombina III/tratamiento farmacológico , Atención Perioperativa , Fusión Vertebral , Deficiencia de Antitrombina III/complicaciones , Femenino , Humanos , Adulto Joven
13.
Anesth Analg ; 115(1): 82-7, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22467885

RESUMEN

BACKGROUND: Many technologies have been developed for minimally invasive monitoring of cardiac output. Estimated continuous cardiac output (esCCO) measurement using pulse wave transit time is one noninvasive method. Because it does not require any additional sensors other than those for conducting 3 basic forms of monitoring (electrocardiogram, pulse oximeter wave, and noninvasive (or invasive) arterial blood pressure measurement), esCCO measurement is potentially useful in routine clinical circulatory monitoring for any patient including low-risk patients. We evaluated the efficacy of noninvasive esCCO using pulse wave transit time in this multicenter study. METHODS: We compared esCCO and intermittent bolus thermodilution cardiac output (TDCO) in 213 patients, 139 intensive care units (ICUs), and 74 operating rooms (ORs), at 7 participating institutions. We performed electrocardiogram, pulse oximetry, TDCO, and arterial blood pressure measurements in patients in ICUs and ORs; a single calibration was performed to measure esCCO continuously. TDCO measurement was performed once daily for ICU patients and every hour for OR patients, and just before the removal of the pulmonary arterial catheter from patients in both the ICU and OR. We evaluated esCCO against TDCO with correlation analysis and Bland and Altman analysis and also assessed the change of bias over time. Furthermore, we inspected the impact of change in systemic vascular resistance (SVR) on change in bias because abnormal SVR was assumed to be a factor contributing to the change of the bias. RESULTS: From among 588 esCCO and TDCO datasets (excluding calibration points), 587 datasets were analyzed for 213 patients. The analysis results show a correlation coefficient of 0.79 (P < 0.0001, 95% confidence limits of 0.756-0.819), a bias (mean difference between esCCO and TDCO) of 0.13 L/min (95% confidence interval of bias 0.04-0.22 L/min), and a precision (1 SD) of 1.15 L/min (95% prediction interval was -2.13 to 2.39 L/min). There were no significant differences among 3 defined time intervals over 48 hours after calibration (repeated-measures analysis of variance P = 0.781) in the ICU. The influence of SVR on esCCO analysis showed a correlation coefficient between SVR and an error of 0.37 (P < 0.0001, 95% confidence interval 0.298-0.438). CONCLUSION: The efficacy of noninvasive esCCO technology was compared with TDCO in 213 cases. Five hundred eighty-seven datasets comparing esCCO and TDCO showed close correlation and small bias and precision, which were comparable to current arterial waveform analysis technologies.


Asunto(s)
Gasto Cardíaco , Monitoreo Fisiológico/métodos , Flujo Pulsátil , Termodilución , Anciano , Análisis de Varianza , Velocidad del Flujo Sanguíneo , Presión Sanguínea , Determinación de la Presión Sanguínea , Calibración , Cateterismo de Swan-Ganz , Cuidados Críticos , Electrocardiografía , Femenino , Frecuencia Cardíaca , Humanos , Japón , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/métodos , Monitoreo Fisiológico/normas , Oximetría , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Termodilución/normas , Factores de Tiempo , Resistencia Vascular
14.
J Clin Monit Comput ; 26(6): 465-71, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22854918

RESUMEN

A new non-invasive continuous cardiac output (esCCO) monitoring system solely utilizing a routine cardiovascular monitor was developed, even though a reference cardiac output (CO) is consistently required. Subsequently, a non-invasive patient information CO calibration together with a new automated exclusion algorithm was implemented in the esCCO system. We evaluated the accuracy and trending ability of the new esCCO system. Either operative or postoperative data of a multicenter study in Japan for evaluation of the accuracy of the original version of esCCO system were used to develop the new esCCO system. A total of 207 patients, mostly cardiac surgical patients, were enrolled in the study. Data were manually reviewed to formulate a new automated exclusion algorithm with enhanced accuracy. Then, a new esCCO system based on a patient information calibration together with the automated exclusion algorithm was developed. CO measured with a new esCCO system was compared with the corresponding intermittent bolus thermodilution CO (ICO) utilizing statistical methods including polar plots analysis. A total of 465 sets of CO data obtained using the new esCCO system were evaluated. The difference in the CO value between the new esCCO and ICO was 0.34 ± 1.50 (SD) L/min (95 % confidence limits of -2.60 to 3.28 L/min). The percentage error was 69.6 %. Polar plots analysis showed that the mean polar angle was -1.6° and radial limits of agreement were ±53.3°. This study demonstrates that the patient information calibration is clinically useful as ICO, but trending ability of the new esCCO system is not clinically acceptable as judged by percentage error and polar plots analysis, even though it's trending ability is comparable with currently available arterial waveform analysis methods.


Asunto(s)
Gasto Cardíaco , Monitoreo Intraoperatorio , Monitoreo Fisiológico , Anciano , Algoritmos , Calibración , Procedimientos Quirúrgicos Cardíacos , Cateterismo de Swan-Ganz , Electrocardiografía , Femenino , Humanos , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/instrumentación , Monitoreo Fisiológico/instrumentación , Termodilución
15.
Masui ; 61(9): 1011-7, 2012 Sep.
Artículo en Japonés | MEDLINE | ID: mdl-23012842

RESUMEN

BACKGROUND: esCCO (estimated continuous cardiac output, Nihon Kohden, esCCO) is a new cardiac output measurement system which uses pulse wave transit time to calculate cardiac output continuously and non-invasively. One of the most commonly used methods to monitor cardiac output is continuous cardiac output CCO (Edwards Lifesciences) which has an accuracy equivalent to that of thermodilution method. METHODS: We compared esCCO to CCO in 67 operating room patients and 128 intensive care unit patients. CCO and esCCO were measured simultaneously in patients with a pulmonary artery catheter inserted after admission to the operating room or intensive care unit. RESULTS: CCO and esCCO showed a high correlation with a correlation coefficient of 0.84 in 496 total data points, and 95% limits of agreement between these two methods were -2.49 to 2.35 l x min(-1). CONCLUSIONS: This result suggests that esCCO could be used to measure cardiac output accurately and non-invasively in different cases.


Asunto(s)
Gasto Cardíaco , Monitoreo Intraoperatorio/instrumentación , Monitoreo Fisiológico/instrumentación , Análisis de la Onda del Pulso , Difusión Térmica , Femenino , Humanos , Unidades de Cuidados Intensivos , Masculino , Quirófanos , Sensibilidad y Especificidad , Factores de Tiempo
16.
Anesth Analg ; 113(2): 272-4, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21467564

RESUMEN

BACKGROUND: The purpose of this study was to determine the effects of transient arterial blood pressure change on the accuracy of the FloTrac™/Vigileo™ monitor (Edwards Lifesciences, Irvine, CA). METHODS: We compared stroke volume determined with the FloTrac/Vigileo with Doppler during anesthetic induction in 20 patients undergoing abdominal aortic reconstruction. RESULTS: The difference between the FloTrac measurements of stroke volume and the Doppler measurements of stroke volume was -7.5 ± 20.5 mL (mean ± SD) before induction, 0.3 ± 14.9 before laryngoscopy, 17.5 ± 26.9 during laryngoscopy, 20.5 ± 27.6, and -4.5 ± 16.4 mL 3 minutes after endotracheal tube placement. CONCLUSION: The FloTrac/Vigileo measured stroke volume with reasonable accuracy during transient hypotension but overestimated stroke volume during transient hypertension.


Asunto(s)
Presión Sanguínea/fisiología , Gasto Cardíaco/fisiología , Hemodinámica/fisiología , Monitoreo Intraoperatorio/métodos , Anciano , Anestesia , Aorta Abdominal/cirugía , Ecocardiografía , Femenino , Humanos , Intubación Intratraqueal , Laringoscopía , Masculino , Reproducibilidad de los Resultados , Programas Informáticos , Volumen Sistólico/fisiología , Procedimientos Quirúrgicos Vasculares
17.
JA Clin Rep ; 6(1): 95, 2020 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-33289045

RESUMEN

BACKGROUND: Recognition of rocuronium-induced anaphylaxis is often challenging, owing to its diverse clinical manifestations. Regarding treatment, several reports have described the efficacy of sugammadex, while conflicting reports have also been published. CASE: A 71-year-old man was scheduled to undergo split-thickness skin grafting surgery on his hip. During the induction of general anesthesia, the patient developed profound circulatory collapse without any cutaneous manifestations, which required 40 min of cardiopulmonary resuscitation. Later, the patient developed circulatory collapse again during the induction of anesthesia for tracheostomy surgery, which apparently coincided with the administration of rocuronium. Rocuronium-induced anaphylactic shock was suspected, and the administration of sugammadex resulted in swift recovery of hemodynamics. The basophil activation test revealed a positive reaction to rocuronium. CONCLUSION: The possibility of rocuronium-induced anaphylaxis should be considered when the circulatory collapse coincides with rocuronium administration, even though cutaneous manifestation is absent. Sugammadex can be a treatment option in such atypical cases.

18.
JA Clin Rep ; 6(1): 13, 2020 02 14.
Artículo en Inglés | MEDLINE | ID: mdl-32060808

RESUMEN

The Editor-in-Chief has retracted this article [1]. The ethics committee approval was granted for an observational study and the need for patient consent was waived. However, the study design described is a randomized controlled trial and therefore patient consent should have been obtained. All authors agree with this retraction.

19.
Anesth Analg ; 109(1): 119-23, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19535701

RESUMEN

BACKGROUND: We hypothesized that mixed venous hemoglobin oxygen saturation (SvO2) can be estimated by calculation from CO2 production, cardiac output, and arterial oxygen saturation measured using a noninvasive cardiac output (NICO) monitor (Novametrix-Respironics, Wallingford, CT). METHODS: Twenty-three patients undergoing aortic aneurysm repair underwent SvO2 monitoring using a pulmonary artery catheter and cardiac output monitoring using a NICO monitor. The estimated SvO2 value calculated from NICO monitor-derived values was compared with the SvO2 value measured using a pulmonary artery catheter. The accuracy of this estimation was analyzed with Bland-Altman method. The ability of this estimation to track the change of SvO2 was also evaluated using correlation analysis to compare the changes of estimated SvO2 and measured SvO2. RESULTS: The bias +/- limits of agreement of the estimated SvO2 against measured SvO2 was -2.1% +/- 11.2%. The change of estimated SvO2 was modestly correlated with the change of measured SvO2. CONCLUSIONS: SvO2 derived from the values measured by the NICO monitor cannot be used interchangeably with the values measured spectrophotometrically using the pulmonary artery catheter. More refinement is required to obtain more reliable estimate of SvO2 less invasively. However, large changes of SvO2 may be detected with this method and can be used as a precautionary sign when the balance between oxygen supply and demand is compromised without inserting a central venous catheter.


Asunto(s)
Gasto Cardíaco/fisiología , Hemoglobinas/metabolismo , Monitoreo Intraoperatorio/instrumentación , Monitoreo Intraoperatorio/métodos , Oxígeno/sangre , Anciano , Anciano de 80 o más Años , Dióxido de Carbono/sangre , Femenino , Hemoglobinas/análisis , Humanos , Masculino , Persona de Mediana Edad , Consumo de Oxígeno/fisiología , Estudios Prospectivos
20.
J Clin Monit Comput ; 23(3): 149-55, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19301132

RESUMEN

OBJECTIVE: This study investigated the accuracy of the NICO monitor equipped with the newer software. Additionally, the effects of the increased dead space produced by the NICO monitor on ventilatory settings were investigated. METHODS: Forty-two patients undergoing elective aortic reconstruction participated in this prospective, observational study at a university hospital. Cardiac output was continuously monitored using both the NICO monitor and continuous cardiac output (CCO) measured by a pulmonary artery catheter. A NICO monitor equipped with ver. 4.2 software was used for the first 21 patients while a NICO monitor equipped with ver. 5.0 software was used for the rest of the patients. Cardiac output measured by bolus thermodilution (BCO) at 30 min intervals was used as a reference. RESULTS: The bias +/- precision of the NICO monitor was 0.18 +/- 0.88 l/min with ver. 4.2 software (n = 182) and 0.18 +/- 0.83 l/min with 5.0 software (n = 194). The accuracy of the NICO monitor is comparable to CCO, whose bias +/- precision against BCO is 0.19 +/- 0.81 l/min (n = 376). At the same level of CO(2) production and minute ventilation, PaCO(2) was lower in the patients monitored by NICO with ver. 5.0 software than patients with ver. 4.2 software. CONCLUSIONS: This study demonstrated the improved performance of the NICO monitor with updated software. The performance of the NICO monitor with ver. 4.2 or later software is similar to CCO. However, the cardiac output measurement did not fulfill the criteria of interchangeability to the cardiac output measurement by bolus thermodilution. Updates to ver. 5.0 attenuated the effects of rebreathing introduced by the NICO monitor without compromising the accuracy of the cardiac output measurement.


Asunto(s)
Capnografía/instrumentación , Capnografía/métodos , Dióxido de Carbono/análisis , Gasto Cardíaco , Diagnóstico por Computador/instrumentación , Diagnóstico por Computador/métodos , Programas Informáticos , Anciano , Algoritmos , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA